28. ROOF IDIQ Bid Shedule.xls
XLS spreadsheet 166 KB Posted
- Attached to
- Roofing Systems IDIQ Federal contract opportunity
- Solicitation number
- FA4690-11-B-0101
About this file
Roof IDIQ Bid Schedule
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOF WO BUILDER MULTI
| $1.00 | $2.00 | $3.00 | $4.00 | |||||||
| BASE YEAR GOVT EST: 2010-2014 ROOF IDIQ CONTRACT | ||||||||||
| CLIN | DESCRIPTION | UNIT OF ISSUE | UNIT COST | ESTIMATED QUANTITY | EXTENDED COST | UNIT COST | ||||
| ASPHALT SHINGLES | ||||||||||
| 0000 | AA | Remove and replace individual shingles; match existing | SF | $3.50 | 500 | $1,750.00 | $3.64 | $3.79 | $3.94 | $4.09 |
| 0000 | AB | Remove shingles, edge metal and underlayment for reroof; one or two layers | SF | $0.60 | 8,000 | $4,800.00 | $0.62 | $0.65 | $0.67 | $0.70 |
| 0000 | AC | Install edge metal for reroof | LF | $1.20 | 600 | $720.00 | $1.25 | $1.30 | $1.35 | $1.40 |
| 0000 | AD | Install laminated architectural shingles; Class A, 290 lb/sq; | SF | $1.60 | 8,000 | $12,800.00 | $1.66 | $1.73 | $1.80 | $1.87 |
| WOOD | ||||||||||
| 0000 | BA | Remove and replace deteriorated wood decking, isolated areas, 1" max thickness | SF | $3.10 | 320 | $992.00 | $3.22 | $3.35 | $3.49 | $3.63 |
| 0000 | BB | Install 7/16" OSB sheathing | SF | $1.70 | 6,000 | $10,200.00 | $1.77 | $1.84 | $1.91 | $1.99 |
| 0000 | BC | Install 19/32" OSB sheathing | SF | $2.00 | 4,000 | $8,000.00 | $2.08 | $2.16 | $2.25 | $2.34 |
| 0000 | BD | Install 19/32" OSB backing for single-ply membrane | SF | $2.60 | 2,000 | $5,200.00 | $2.70 | $2.81 | $2.92 | $3.04 |
| 0000 | BE | Remove existing wood framing, curbing, blocking and nailers | BF | $0.90 | 3,000 | $2,700.00 | $0.94 | $0.97 | $1.01 | $1.05 |
| 0000 | BF | Install treated wood cants, curbing, blocking and nailers | BF | $3.00 | 5,000 | $15,000.00 | $3.12 | $3.24 | $3.37 | $3.51 |
| 0000 | BG | Install wood framing | BF | $3.40 | 1,000 | $3,400.00 | $3.54 | $3.68 | $3.82 | $3.98 |
| 0000 | BH | Install prefabricated wood trusses; 4/12 max pitch | SF | $4.00 | 6,000 | $24,000.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | BI | Remove existing wood trim & fascia board | SF | $1.25 | 1,000 | $1,250.00 | $1.30 | $1.35 | $1.41 | $1.46 |
| 0000 | BJ | Install painted wood trim and fascia board | BF | $4.00 | 500 | $2,000.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| ROOF INSULATION | ||||||||||
| 0000 | CA | Remove existing insulation | BF | $0.50 | 20,000 | $10,000.00 | $0.52 | $0.54 | $0.56 | $0.58 |
| 0000 | CB | Install tapered polyisocyanurate insulation | BF | $2.00 | 5,000 | $10,000.00 | $2.08 | $2.16 | $2.25 | $2.34 |
| 0000 | CC | Install coverboard for PVC or EPDM recover | SF | $1.00 | 4,000 | $4,000.00 | $1.04 | $1.08 | $1.12 | $1.17 |
| 0000 | CD | Install 1" perlite insulation | SF | $0.95 | 2,000 | $1,900.00 | $0.99 | $1.03 | $1.07 | $1.11 |
| 0000 | CE | Install 3" polyisocyanurate insulation | SF | $2.00 | 10,000 | $20,000.00 | $2.08 | $2.16 | $2.25 | $2.34 |
| 0000 | CF | Install 4" polyisocyanurate insulation | SF | $2.50 | 16,000 | $40,000.00 | $2.60 | $2.70 | $2.81 | $2.92 |
| 0000 | CG | Install 1-1/2" fiberglass batt insulation, unfaced | SF | $0.60 | 8,000 | $4,800.00 | $0.62 | $0.65 | $0.67 | $0.70 |
| 0000 | CH | Install R19 fiberglass batt insulation, unfaced | SF | $1.30 | 500 | $650.00 | $1.35 | $1.41 | $1.46 | $1.52 |
| 0000 | CI | Install R38 fiberglass batt insulation, unfaced | SF | $1.90 | 2,000 | $3,800.00 | $1.98 | $2.06 | $2.14 | $2.22 |
| 0000 | CJ | Install 6 mil polyethelene vapor barrier | SF | $0.30 | 8,000 | $2,400.00 | $0.31 | $0.32 | $0.34 | $0.35 |
| METAL ROOFING SYSTEMS | ||||||||||
| 0000 | DA | Remove existing metal roof or wall panels and flashings | SF | $1.20 | 200 | $240.00 | $1.25 | $1.30 | $1.35 | $1.40 |
| 0000 | DB | Reattach existing loose metal roof or wall panels and flashings | SF | $1.30 | 1,000 | $1,300.00 | $1.35 | $1.41 | $1.46 | $1.52 |
| 0000 | DC | Install corrugated aluminum roof or wall panels, field painted | SF | $7.50 | 100 | $750.00 | $7.80 | $8.11 | $8.44 | $8.77 |
| 0000 | DD | Install corrugated steel roof or wall panels, field painted | SF | $7.00 | 100 | $700.00 | $7.28 | $7.57 | $7.87 | $8.19 |
| 0000 | DE | Install struct. SSMR system over purlins (not incl. insulation, flashings, closures, gutters and curbs): 20 yr warr. | SF | $8.00 | 4,000 | $32,000.00 | $8.32 | $8.65 | $9.00 | $9.36 |
| 0000 | DF | Install arch. SSMR system over substrate (not incl. insulation, flashings, closures, gutters and curbs): 20 yr warr. | SF | $7.50 | 8,000 | $60,000.00 | $7.80 | $8.11 | $8.44 | $8.77 |
| 0000 | DG | Install light-gage steel supports for structural SSMR system incl. purlins, subpurlins, rafters, columns, braces and fasteners | LB | $6.00 | 2,000 | $12,000.00 | $6.24 | $6.49 | $6.75 | $7.02 |
| 0000 | DH | Install SSMR system flashing for rake, eave, sidewall or headwall incl. fasteners, closures, sealants, and counterflashing | LF | $6.00 | 400 | $2,400.00 | $6.24 | $6.49 | $6.75 | $7.02 |
| 0000 | DI | Install SSMR system flashing for ridge, hip or valley including all fasteners, closures, sealants, and counterflashing | LF | $8.00 | 600 | $4,800.00 | $8.32 | $8.65 | $9.00 | $9.36 |
| 0000 | DJ | Install SSMR system snow retention system, S-5 Color Guard w/snow clips, or equal | LF | $14.00 | 400 | $5,600.00 | $14.56 | $15.14 | $15.75 | $16.38 |
| BUILT-UP ROOFING SYSTEM (BURS) | ||||||||||
| 0000 | EA | Spud and remove existing gravel for recover | SF | $1.00 | 1,000 | $1,000.00 | $1.04 | $1.08 | $1.12 | $1.17 |
| 0000 | EB | Sweep and spud gravel for repair, store on roof | SF | $0.85 | 300 | $255.00 | $0.88 | $0.92 | $0.96 | $0.99 |
| 0000 | EC | Remove BUR for replace, incl. gravel, flashing, cants and 3" of insulation | SF | $1.00 | 15,000 | $15,000.00 | $1.04 | $1.08 | $1.12 | $1.17 |
| 0000 | ED | Install gravel with hot asphalt | SF | $0.85 | 300 | $255.00 | $0.88 | $0.92 | $0.96 | $0.99 |
| 0000 | EE | Install agg.-surfaced 4-ply BURS w/base; not incl. insulation, flashings and access, 20 yr mfr. warr. | SF | $4.00 | 2,000 | $8,000.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | EF | Repair blisters and splits in BUR membrane per NRCA repair guidelines | SF | $6.00 | 100 | $600.00 | $6.24 | $6.49 | $6.75 | $7.02 |
| 0000 | EG | Repair wind scours per NRCA repair guidelines | SF | $3.00 | 200 | $600.00 | $3.12 | $3.24 | $3.37 | $3.51 |
| 0000 | EH | Install 2-ply mopped roof for vapor barrier or temp roof | SF | $2.50 | 500 | $1,250.00 | $2.60 | $2.70 | $2.81 | $2.92 |
| SINGLE-PLY ROOFING SYSTEMS | ||||||||||
| 0000 | FA | Install .060" fully-adhered EPDM membrane roof system; not incl. insulation, flashings and accessories; 20 yr mfr. warr. | SF | $3.50 | 8,000 | $28,000.00 | $3.64 | $3.79 | $3.94 | $4.09 |
| 0000 | FB | Install EPDM flashing system on .060" EPDM roof edges; incl. fasteners, sealants, adhesives, cover strips and access. (not incl. nailers, cants and metal flashings) | LF | $5.00 | 700 | $3,500.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | FC | Install EPDM roof membrane patch | SF | $4.00 | 10 | $40.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | FD | Install .060" fully-adhered PVC membrane roof system; not incl. insulation, flashings and accessories; 20 yr mfr. warr. | SF | $4.00 | 10,000 | $40,000.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | FE | Install PVC flashing system on .060" EPDM roof edges; incl. fasteners, sealants, adhesives, cover strips and access. (not incl. nailers, cants and metal flashings) | LF | $5.50 | 800 | $4,400.00 | $5.72 | $5.95 | $6.19 | $6.43 |
| 0000 | FF | Install PVC roof membrane patch | SF | $5.00 | 5 | $25.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | FG | Install water-based, liquid acrylic roofing membrane, TOPCOAT or approved equal, two coats | SF | $4.00 | 500 | $2,000.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | FH | Install synthetic rubber waterproofing elastomeric sealant, TOPCOAT FLASHING GRADE or approved equal, | SF | $4.00 | 500 | $2,000.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | FI | Install non-woven, spunbound polyester seam reinforcing fabric, TOPCOAT TOPESTER or approved equal | SF | $1.20 | 300 | $360.00 | $1.25 | $1.30 | $1.35 | $1.40 |
| FLASHINGS AND METALS | ||||||||||
| 0000 | GA | Remove and replace base flashing for repair, <5' per location | LF | $5.00 | 50 | $250.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | GB | Remove existing base flashing and fiber cants | LF | $1.50 | 200 | $300.00 | $1.56 | $1.62 | $1.69 | $1.75 |
| 0000 | GC | Install 2-ply mineral-surfaced modified bitumen base flashing | LF | $5.00 | 200 | $1,000.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | GD | Remove, clean, straighten and reinstall sheet metal flashing | LF | $2.50 | 800 | $2,000.00 | $2.60 | $2.70 | $2.81 | $2.92 |
| 0000 | GE | Sawcut for reglet in masonry or concrete | LF | $4.00 | 200 | $800.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | GF | Install Kynar-finished steel counter flashing | LF | $4.50 | 1,000 | $4,500.00 | $4.68 | $4.87 | $5.06 | $5.26 |
| 0000 | GG | Install and strip-in 24 ga. Kynar-finished steel gravel stop (up to 8"face) | LF | $5.00 | 100 | $500.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | GH | Remove existing sheet metal fascia, coping and flashing | SF | $0.60 | 2,000 | $1,200.00 | $0.62 | $0.65 | $0.67 | $0.70 |
| 0000 | GI | Install 24 ga. Kynar-finished fascia, coping and flashing | SF | $5.00 | 3,000 | $15,000.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | GJ | Install 24 ga. Kynar-finished soffit panel, plain or vented | SF | $4.50 | 800 | $3,600.00 | $4.68 | $4.87 | $5.06 | $5.26 |
| 0000 | GK | Increased cost for vented ridge flashing vs non-vented | LF | $7.00 | 300 | $2,100.00 | $7.28 | $7.57 | $7.87 | $8.19 |
| 0000 | GL | Install 24 ga. galvanized steel continous cleat | LF | $3.20 | 1,000 | $3,200.00 | $3.33 | $3.46 | $3.60 | $3.74 |
| 0000 | GM | Install 4 lb. lead flashing | SF | $5.00 | 100 | $500.00 | $5.20 | $5.41 | $5.62 | $5.85 |
| 0000 | GN | Install pipe penetration flashing: 0 to 6" dia. | EA | $40.00 | 40 | $1,600.00 | $41.60 | $43.26 | $44.99 | $46.79 |
| 0000 | GO | Install pipe penetration flashing: 6"+ to 12" dia. | EA | $50.00 | 5 | $250.00 | $52.00 | $54.08 | $56.24 | $58.49 |
| GUTTERS AND DOWNSPOUTS | ||||||||||
| 0000 | JA | Clean out gutters and downspouts | LF | $1.00 | 300 | $300.00 | $1.04 | $1.08 | $1.12 | $1.17 |
| 0000 | JB | Remove existing gutters and downspouts | LF | $0.70 | 500 | $350.00 | $0.73 | $0.76 | $0.79 | $0.82 |
| 0000 | JC | Rehang and correct pitch of existing gutters/spouts | LF | $3.50 | 100 | $350.00 | $3.64 | $3.79 | $3.94 | $4.09 |
| 0000 | JD | Install Kynar pre-finished sheet metal gutters | LF | $8.00 | 1,000 | $8,000.00 | $8.32 | $8.65 | $9.00 | $9.36 |
| 0000 | JE | Install Kynar pre-finished sheet metal downspouts | LF | $7.50 | 800 | $6,000.00 | $7.80 | $8.11 | $8.44 | $8.77 |
| 0000 | JF | Install Kynar pre-finishedsheet metal roof scupper box | EA | $100.00 | 5 | $500.00 | $104.00 | $108.16 | $112.49 | $116.99 |
| 0000 | JG | Install precast concrete splash blocks | EA | $30.00 | 20 | $600.00 | $31.20 | $32.45 | $33.75 | $35.10 |
| SEALANTS | ||||||||||
| 0000 | KA | Remove existing backer rod and sealant, clean joint for reseal | LF | $1.25 | 300 | $375.00 | $1.30 | $1.35 | $1.41 | $1.46 |
| 0000 | KB | Install backer rod and polyurethane sealant: 0 to 1/2" wide | LF | $3.50 | 150 | $525.00 | $3.64 | $3.79 | $3.94 | $4.09 |
| 0000 | KC | Install backer rod and polyurethane sealant: >1/2" to 3/4" wide | LF | $4.00 | 100 | $400.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | KD | Install backer rod and polyurethane sealant: >3/4" wide | LF | $4.50 | 50 | $225.00 | $4.68 | $4.87 | $5.06 | $5.26 |
| 0000 | KE | Install polyurethane sealant, misc. joints and seams: no backer rod | LB | $15.00 | 150 | $2,250.00 | $15.60 | $16.22 | $16.87 | $17.55 |
| 0000 | KF | Install butyl sealant, misc. joints and seams: no backer rod | LB | $15.00 | 100 | $1,500.00 | $15.60 | $16.22 | $16.87 | $17.55 |
| ROOF DRAINS | ||||||||||
| 0000 | LA | Clean in and around roof drains | EA | $25.00 | 15 | $375.00 | $26.00 | $27.04 | $28.12 | $29.25 |
| 0000 | LB | Remove existing roof drain | EA | $100.00 | 4 | $400.00 | $104.00 | $108.16 | $112.49 | $116.99 |
| 0000 | LC | Install new 4" roof drain in wood or steel deck | EA | $500.00 | 2 | $1,000.00 | $520.00 | $540.80 | $562.43 | $584.93 |
| 0000 | LD | Install new 4" roof drain piping | LF | $25.00 | 50 | $1,250.00 | $26.00 | $27.04 | $28.12 | $29.25 |
| 0000 | LE | Install new clamp ring and bolts | EA | $60.00 | 20 | $1,200.00 | $62.40 | $64.90 | $67.49 | $70.19 |
| 0000 | LF | Install new strainer basket | EA | $40.00 | 10 | $400.00 | $41.60 | $43.26 | $44.99 | $46.79 |
| 0000 | LG | Re-flash existing drain in BUR w/ new flashing, gravel guard and strip-in | EA | $170.00 | 5 | $850.00 | $176.80 | $183.87 | $191.23 | $198.88 |
| 0000 | LH | Re-flash existing drain in single ply roof | EA | $100.00 | 30 | $3,000.00 | $104.00 | $108.16 | $112.49 | $116.99 |
| 0000 | LI | Install 4" PVC retrofit drain insert | EA | $130.00 | 5 | $650.00 | $135.20 | $140.61 | $146.23 | $152.08 |
| MISCELLANEOUS TASKS | ||||||||||
| 0000 | MA | Crane Rental w/ Operator, per day | Day | $1,200.00 | 10 | $12,000.00 | $1,248.00 | $1,297.92 | $1,349.84 | $1,403.83 |
| 0000 | MB | Install aluminum roof coating | SF | $0.80 | 200 | $160.00 | $0.83 | $0.87 | $0.90 | $0.94 |
| 0000 | MC | Install new EPDM walkway pad | SF | $4.00 | 200 | $800.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | MD | Install new asphalt plank walkway | SF | $4.00 | 20 | $80.00 | $4.16 | $4.33 | $4.50 | $4.68 |
| 0000 | ME | Install new concrete paver walkway | SF | $6.00 | 200 | $1,200.00 | $6.24 | $6.49 | $6.75 | $7.02 |
| 0000 | MF | Fabricate & install plumbers vent extension 2-6" diam | LF | $35.00 | 30 | $1,050.00 | $36.40 | $37.86 | $39.37 | $40.95 |
| 0000 | MG | Install neoprene expansion joint cover (not incl. curbs and flashings) | LF | $17.00 | 100 | $1,700.00 | $17.68 | $18.39 | $19.12 | $19.89 |
| 0000 | MH | Remove and re-install existing ventilator | EA | $70.00 | 50 | $3,500.00 | $72.80 | $75.71 | $78.74 | $81.89 |
| 0000 | MI | Remove and re-install rooftop mounted equipment | LB | $2.00 | 2,000 | $4,000.00 | $2.08 | $2.16 | $2.25 | $2.34 |
| 0000 | MJ | Fill pitch pans | EA | $40.00 | 20 | $800.00 | $41.60 | $43.26 | $44.99 | $46.79 |
| 0000 | MK | Install water & ice shield | SF | $1.00 | 2,000 | $2,000.00 | $1.04 | $1.08 | $1.12 | $1.17 |
| 0000 | ML | Install synthetic rubberized underlayment; CETCO Strongseal or equal | SF | $1.20 | 6,000 | $7,200.00 | $1.25 | $1.30 | $1.35 | $1.40 |
| 0000 | MM | Install 15 lb. felt underlayment, no mopping | SF | $0.25 | 8,000 | $2,000.00 | $0.26 | $0.27 | $0.28 | $0.29 |
| 0000 | MN | Install 30 lb. felt underlayment, no mopping | SF | $0.35 | 4,000 | $1,400.00 | $0.36 | $0.38 | $0.39 | $0.41 |
| 0000 | MO | Remove existing, deteriorated steel roof decking | SF | $1.50 | 100 | $150.00 | $1.56 | $1.62 | $1.69 | $1.75 |
| 0000 | MP | Install new steel roof decking to match existing | SF | $4.50 | 100 | $450.00 | $4.68 | $4.87 | $5.06 | $5.26 |
| 0000 | MQ | Field paint wood or metal surface | SF | $0.50 | 500 | $250.00 | $0.52 | $0.54 | $0.56 | $0.58 |
| 0000 | MR | Siloxane Masonry Water Repellant | 5 Gal | $250.00 | 2 | $500.00 | $260.00 | $270.40 | $281.22 | $292.46 |
| MOBILIZATION AND SERVICE CALLS | ||||||||||
| 0000 | NA | Leak service call (Two-man crew, three hours on-site, first $100 in materials) | EA | $600.00 | 15 | $9,000.00 | $624.00 | $648.96 | $674.92 | $701.92 |
| 0000 | NB | After hours leak service call | EA | $900.00 | 2 | $1,800.00 | $936.00 | $973.44 | $1,012.38 | $1,052.87 |
| 0000 | NC | Extended time on site for service call crew, when authorized | HR | $100.00 | 10 | $1,000.00 | $104.00 | $108.16 | $112.49 | $116.99 |
| 0000 | ND | Mobilization of roof repair crew, once each per facility, per delivery order | EA | $300.00 | 20 | $6,000.00 | $312.00 | $324.48 | $337.46 | $350.96 |
| 0000 | NE | Mobilization and prep. of asphalt kettle, once each per facility, per delivery order | EA | $450.00 | 5 | $2,250.00 | $468.00 | $486.72 | $506.19 | $526.44 |
| TOTAL | $544,027.00 |
&C&"Arial,Bold"ROOFING SYSTEMS MAINTENANCE AND REPAIR, ELLSWORTH AFB
&C&P OF &N&RGOV ESTIMATE
2011 Base Year
| BASE YEAR GOVT EST: 2011-2016 ROOF IDIQ CONTRACT | ||||||
| CLIN | DESCRIPTION | UNIT OF ISSUE | UNIT COST | ESTIMATED QUANTITY | EXTENDED COST | |
| ASPHALT SHINGLES | ||||||
| 0001 | AA | Remove and replace individual shingles; match existing | SF | 500 | ||
| 0001 | AB | Remove shingles, edge metal and underlayment for reroof | SF | 8,000 | ||
| 0001 | AC | Install edge metal for reshingling | LF | 600 | ||
| 0001 | AD | Install laminated architectural shingles | SF | 8,000 | ||
| WOOD | ||||||
| 0001 | AE | Remove and replace deteriorated wood decking | SF | 320 | ||
| 0001 | AF | Install 1/2" CDX plywood sheathing | SF | 6,000 | ||
| 0001 | AG | Install 7/16" OSB sheathing | SF | 6,000 | ||
| 0001 | AH | Install 19/32" OSB sheathing | SF | 4,000 | ||
| 0001 | AJ | Install 19/32" OSB backing for roof membrane flashings | SF | 2,000 | ||
| 0001 | AK | Remove existing wood framing, curbing, blocking and nailers | BF | 3,000 | ||
| 0001 | AL | Install treated wood cants, curbing, blocking and nailers | BF | 5,000 | ||
| 0001 | AM | Install wood framing | BF | 1,000 | ||
| 0001 | AN | Remove existing wood trim & fascia board | SF | 1,000 | ||
| 0001 | AP | Install wood trim and fascia board | BF | 500 | ||
| ROOF INSULATION | ||||||
| 0001 | AQ | Remove existing insulation | BF | 20,000 | ||
| 0001 | AR | Install tapered polyisocyanurate insulation | BF | 5,000 | ||
| 0001 | AS | Install coverboard for PVC or EPDM recover | SF | 4,000 | ||
| 0001 | AT | Install 3" polyisocyanurate insulation | SF | 10,000 | ||
| 0001 | AU | Install 4" polyisocyanurate insulation | SF | 16,000 | ||
| 0001 | AV | Install 1-1/2" fiberglass batt insulation, unfaced | SF | 8,000 | ||
| 0001 | AW | Install R19 fiberglass batt insulation, unfaced | SF | 500 | ||
| 0001 | AX | Install R38 fiberglass batt insulation, unfaced | SF | 2,000 | ||
| 0001 | AY | Install 6 mil polyethelene vapor barrier | SF | 8,000 | ||
| FA4690-11-B-0101 Attachment 29 Page 2 of 4 | ||||||
| METAL ROOFING SYSTEMS | ||||||
| 0001 | AZ | Remove existing metal roof or wall panels and flashings | SF | 200 | ||
| 0001 | BA | Reattach existing loose metal roof or wall panels and flashings | SF | 1,000 | ||
| 0001 | BB | Install corrugated aluminum roof or wall panels, field painted | SF | 100 | ||
| 0001 | BC | Install corrugated steel roof or wall panels, field painted | SF | 100 | ||
| 0001 | BD | Install SSMR system: 20 yr warr. | SF | 8,000 | ||
| 0001 | BE | Install light-gage steel supports for SSMR system | LB | 2,000 | ||
| 0001 | BF | Install SSMR system flashing for rake, eave, sidewall or headwall | LF | 400 | ||
| 0001 | BG | Install SSMR system flashing for ridge, hip or valley | LF | 600 | ||
| 0001 | BH | Install SSMR system snow retention system | LF | 400 | ||
| BUILT-UP ROOFING SYSTEM (BURS) | ||||||
| 0001 | BJ | Spud and remove existing gravel for recover | SF | 1,000 | ||
| 0001 | BK | Sweep and spud gravel for repair, store on roof | SF | 300 | ||
| 0001 | BL | Remove BUR for roof replacement | SF | 15,000 | ||
| 0001 | BM | Install gravel with hot asphalt | SF | 300 | ||
| 0001 | BN | Repair blisters and splits in BUR membrane | SF | 100 | ||
| 0001 | BP | Repair wind scours | SF | 200 | ||
| 0001 | BQ | Install 2-ply mopped roof | SF | 500 | ||
| SINGLE-PLY ROOFING SYSTEMS | ||||||
| 0001 | BR | Install .060" fully-adhered EPDM membrane roof system | SF | 8,000 | ||
| 0001 | BS | Install EPDM flashing system on .060" EPDM | LF | 700 | ||
| 0001 | BT | Install EPDM roof membrane patch | SF | 10 | ||
| 0001 | BU | Install .060" fully-adhered PVC membrane roof system | SF | 10,000 | ||
| 0001 | BW | Install PVC flashing system on .060" PVC | LF | 800 | ||
| 0001 | BX | Install PVC roof membrane patch | SF | 5 | ||
| 0001 | BY | Install water-based, liquid acrylic roofing membrane | SF | 500 | ||
| 0001 | BZ | Install synthetic rubber waterproofing elastomeric sealant | SF | 500 | ||
| 0001 | CA | Install non-woven, spunbound polyester seam reinforcing fabric | SF | 300 | ||
| FA4690-11-B-0101 Attachment 29 Page 3 of 4 | ||||||
| FLASHINGS AND METALS | ||||||
| 0001 | CB | Remove and replace base flashing for repair | LF | 50 | ||
| 0001 | CC | Remove existing base flashing and fiber cants | LF | 200 | ||
| 0001 | CD | Install 2-ply mineral-surfaced modified bitumen base flashing | LF | 200 | ||
| 0001 | CE | Remove, clean, straighten and reinstall sheet metal flashing | LF | 800 | ||
| 0001 | CF | Sawcut for reglet in masonry or concrete | LF | 200 | ||
| 0001 | CG | Install Kynar-finished steel counter flashing | LF | 1,000 | ||
| 0001 | CH | Remove existing sheet metal fascia, coping and flashing | SF | 2,000 | ||
| 0001 | CJ | Install 24 ga. Kynar-finished fascia, coping and flashing | SF | 3,000 | ||
| 0001 | CK | Install 24 ga. Kynar-finished soffit panel, plain or vented | SF | 800 | ||
| 0001 | CL | Increased cost for vented ridge flashing vs non-vented | LF | 300 | ||
| 0001 | CM | Install 24 ga. galvanized steel continous cleat | LF | 1,000 | ||
| 0001 | CN | Install pipe penetration flashing: 0 to 6" dia. | EA | 40 | ||
| 0001 | CP | Install pipe penetration flashing: 6"+ to 12" dia. | EA | 5 | ||
| GUTTERS AND DOWNSPOUTS | ||||||
| 0001 | CQ | Clean out gutters and downspouts | LF | 300 | ||
| 0001 | CR | Remove existing gutters and downspouts | LF | 500 | ||
| 0001 | CS | Install Kynar pre-finished sheet metal gutters | LF | 1,000 | ||
| 0001 | CT | Install Kynar pre-finished sheet metal downspouts | LF | 800 | ||
| 0001 | CU | Install Kynar pre-finishedsheet metal roof scupper box | EA | 5 | ||
| 0001 | CV | Install precast concrete splash blocks | EA | 20 | ||
| SEALANTS | ||||||
| 0001 | CW | Remove existing backer rod and sealant, clean joint for reseal | LF | 300 | ||
| 0001 | CX | Install backer rod and polyurethane sealant: 0 to 1/2" wide | LF | 150 | ||
| 0001 | CY | Install backer rod and polyurethane sealant: >1/2" to 3/4" wide | LF | 100 | ||
| 0001 | CZ | Install backer rod and polyurethane sealant: >3/4" wide | LF | 50 | ||
| 0001 | DA | Install polyurethane sealant, misc. joints and seams | LB | 150 | ||
| 0001 | DB | Install butyl sealant, misc. joints and seams: no backer rod | LB | 100 | ||
| FA4690-11-B-0101 Attachment 29 Page 4 of 4 | ||||||
| ROOF DRAINS | ||||||
| 0001 | DC | Clean in and around roof drains | EA | 15 | ||
| 0001 | DD | Install new clamp ring and bolts | EA | 20 | ||
| 0001 | DE | Install new strainer basket | EA | 10 | ||
| 0001 | DF | Re-flash existing drain in single ply roof | EA | 30 | ||
| MISCELLANEOUS TASKS | ||||||
| 0001 | DG | Install new EPDM walkway pad | SF | 200 | ||
| 0001 | DH | Install new concrete paver walkway | SF | 200 | ||
| 0001 | DJ | Fabricate & install plumbers vent extension 2-4" diam | LF | 30 | ||
| 0001 | DK | Remove and re-install existing ventilator | EA | 50 | ||
| 0001 | DL | Remove and re-install rooftop mounted equipment | LB | 2,000 | ||
| 0001 | DM | Fill pitch pans | EA | 20 | ||
| 0001 | DN | Install water & ice shield | SF | 2,000 | ||
| 0001 | DP | Install synthetic rubberized underlayment | SF | 6,000 | ||
| 0001 | DQ | Install #15 felt underlayment, no mopping | SF | 8,000 | ||
| 0001 | DR | Remove existing, deteriorated steel roof decking | SF | 100 | ||
| 0001 | DS | Install new steel roof decking to match existing | SF | 100 | ||
| 0001 | DT | Field paint wood or metal surface | SF | 500 | ||
| 0001 | DU | Apply Siloxane Masonry Water Repellant | 5 Gal | 2 | ||
| MOBILIZATION AND SERVICE CALLS | ||||||
| 0001 | DW | Leak service call | EA | 25 | ||
| 0001 | DX | After hours leak service call | EA | 3 | ||
| 0001 | DY | Extended time on site for service call crew | HR | 30 | ||
| 0001 | DZ | Mobilization of roofing crew | EA | 15 | ||
| 0001 | EA | Mobilization and prep. of asphalt kettle | EA | 5 | ||
| TOTAL | $0.00 |
&C&"Arial,Bold"ROOFING SYSTEMS MAINTENANCE AND REPAIR, ELLSWORTH AFB &R Attachment 28
FA4690-11-B-0101
2012 1ST OPTION
| 1ST OPTION YEAR GOVT EST: 2011-2015 ROOF IDIQ CONTRACT | ||||||
| CLIN | DESCRIPTION | UNIT OF ISSUE | UNIT COST | ESTIMATED QUANTITY | EXTENDED COST | |
| ASPHALT SHINGLES | ||||||
| 0001 | AA | Remove and replace individual shingles; match existing | SF | 500 | ||
| 0001 | AB | Remove shingles, edge metal and underlayment for reroof | SF | 8,000 | ||
| 0001 | AC | Install edge metal for reshingling | LF | 600 | ||
| 0001 | AD | Install laminated architectural shingles | SF | 8,000 | ||
| WOOD | ||||||
| 0001 | AE | Remove and replace deteriorated wood decking | SF | 320 | ||
| 0001 | AF | Install 1/2" CDX plywood sheathing | SF | 6,000 | ||
| 0001 | AG | Install 7/16" OSB sheathing | SF | 6,000 | ||
| 0001 | AH | Install 19/32" OSB sheathing | SF | 4,000 | ||
| 0001 | AJ | Install 19/32" OSB backing for roof membrane flashings | SF | 2,000 | ||
| 0001 | AK | Remove existing wood framing, curbing, blocking and nailers | BF | 3,000 | ||
| 0001 | AL | Install treated wood cants, curbing, blocking and nailers | BF | 5,000 | ||
| 0001 | AM | Install wood framing | BF | 1,000 | ||
| 0001 | AN | Remove existing wood trim & fascia board | SF | 1,000 | ||
| 0001 | AP | Install wood trim and fascia board | BF | 500 | ||
| ROOF INSULATION | ||||||
| 0001 | AQ | Remove existing insulation | BF | 20,000 | ||
| 0001 | AR | Install tapered polyisocyanurate insulation | BF | 5,000 | ||
| 0001 | AS | Install coverboard for PVC or EPDM recover | SF | 4,000 | ||
| 0001 | AT | Install 3" polyisocyanurate insulation | SF | 10,000 | ||
| 0001 | AU | Install 4" polyisocyanurate insulation | SF | 16,000 | ||
| 0001 | AV | Install 1-1/2" fiberglass batt insulation, unfaced | SF | 8,000 | ||
| 0001 | AW | Install R19 fiberglass batt insulation, unfaced | SF | 500 | ||
| 0001 | AX | Install R38 fiberglass batt insulation, unfaced | SF | 2,000 | ||
| 0001 | AY | Install 6 mil polyethelene vapor barrier | SF | 8,000 | ||
| FA4690-11-B-0101 Attachment 29 Page 2 of 4 | ||||||
| METAL ROOFING SYSTEMS | ||||||
| 0001 | AZ | Remove existing metal roof or wall panels and flashings | SF | 200 | ||
| 0001 | BA | Reattach existing loose metal roof or wall panels and flashings | SF | 1,000 | ||
| 0001 | BB | Install corrugated aluminum roof or wall panels, field painted | SF | 100 | ||
| 0001 | BC | Install corrugated steel roof or wall panels, field painted | SF | 100 | ||
| 0001 | BD | Install SSMR system: 20 yr warr. | SF | 8,000 | ||
| 0001 | BE | Install light-gage steel supports for SSMR system | LB | 2,000 | ||
| 0001 | BF | Install SSMR system flashing for rake, eave, sidewall or headwall | LF | 400 | ||
| 0001 | BG | Install SSMR system flashing for ridge, hip or valley | LF | 600 | ||
| 0001 | BH | Install SSMR system snow retention system | LF | 400 | ||
| BUILT-UP ROOFING SYSTEM (BURS) | ||||||
| 0001 | BJ | Spud and remove existing gravel for recover | SF | 1,000 | ||
| 0001 | BK | Sweep and spud gravel for repair, store on roof | SF | 300 | ||
| 0001 | BL | Remove BUR for roof replacement | SF | 15,000 | ||
| 0001 | BM | Install gravel with hot asphalt | SF | 300 | ||
| 0001 | BN | Repair blisters and splits in BUR membrane | SF | 100 | ||
| 0001 | BP | Repair wind scours | SF | 200 | ||
| 0001 | BQ | Install 2-ply mopped roof | SF | 500 | ||
| SINGLE-PLY ROOFING SYSTEMS | ||||||
| 0001 | BR | Install .060" fully-adhered EPDM membrane roof system | SF | 8,000 | ||
| 0001 | BS | Install EPDM flashing system on .060" EPDM | LF | 700 | ||
| 0001 | BT | Install EPDM roof membrane patch | SF | 10 | ||
| 0001 | BU | Install .060" fully-adhered PVC membrane roof system | SF | 10,000 | ||
| 0001 | BW | Install PVC flashing system on .060" PVC | LF | 800 | ||
| 0001 | BX | Install PVC roof membrane patch | SF | 5 | ||
| 0001 | BY | Install water-based, liquid acrylic roofing membrane | SF | 500 | ||
| 0001 | BZ | Install synthetic rubber waterproofing elastomeric sealant | SF | 500 | ||
| 0001 | CA | Install non-woven, spunbound polyester seam reinforcing fabric | SF | 300 | ||
| FA4690-11-B-0101 Attachment 29 Page 3 of 4 | ||||||
| FLASHINGS AND METALS | ||||||
| 0001 | CB | Remove and replace base flashing for repair | LF | 50 | ||
| 0001 | CC | Remove existing base flashing and fiber cants | LF | 200 | ||
| 0001 | CD | Install 2-ply mineral-surfaced modified bitumen base flashing | LF | 200 | ||
| 0001 | CE | Remove, clean, straighten and reinstall sheet metal flashing | LF | 800 | ||
| 0001 | CF | Sawcut for reglet in masonry or concrete | LF | 200 | ||
| 0001 | CG | Install Kynar-finished steel counter flashing | LF | 1,000 | ||
| 0001 | CH | Remove existing sheet metal fascia, coping and flashing | SF | 2,000 | ||
| 0001 | CJ | Install 24 ga. Kynar-finished fascia, coping and flashing | SF | 3,000 | ||
| 0001 | CK | Install 24 ga. Kynar-finished soffit panel, plain or vented | SF | 800 | ||
| 0001 | CL | Increased cost for vented ridge flashing vs non-vented | LF | 300 | ||
| 0001 | CM | Install 24 ga. galvanized steel continous cleat | LF | 1,000 | ||
| 0001 | CN | Install pipe penetration flashing: 0 to 6" dia. | EA | 40 | ||
| 0001 | CP | Install pipe penetration flashing: 6"+ to 12" dia. | EA | 5 | ||
| GUTTERS AND DOWNSPOUTS | ||||||
| 0001 | CQ | Clean out gutters and downspouts | LF | 300 | ||
| 0001 | CR | Remove existing gutters and downspouts | LF | 500 | ||
| 0001 | CS | Install Kynar pre-finished sheet metal gutters | LF | 1,000 | ||
| 0001 | CT | Install Kynar pre-finished sheet metal downspouts | LF | 800 | ||
| 0001 | CU | Install Kynar pre-finishedsheet metal roof scupper box | EA | 5 | ||
| 0001 | CV | Install precast concrete splash blocks | EA | 20 | ||
| SEALANTS | ||||||
| 0001 | CW | Remove existing backer rod and sealant, clean joint for reseal | LF | 300 | ||
| 0001 | CX | Install backer rod and polyurethane sealant: 0 to 1/2" wide | LF | 150 | ||
| 0001 | CY | Install backer rod and polyurethane sealant: >1/2" to 3/4" wide | LF | 100 | ||
| 0001 | CZ | Install backer rod and polyurethane sealant: >3/4" wide | LF | 50 | ||
| 0001 | DA | Install polyurethane sealant, misc. joints and seams | LB | 150 | ||
| 0001 | DB | Install butyl sealant, misc. joints and seams: no backer rod | LB | 100 | ||
| FA4690-11-B-0101 Attachment 29 Page 4 of 4 | ||||||
| ROOF DRAINS | ||||||
| 0001 | DC | Clean in and around roof drains | EA | 15 | ||
| 0001 | DD | Install new clamp ring and bolts | EA | 20 | ||
| 0001 | DE | Install new strainer basket | EA | 10 | ||
| 0001 | DF | Re-flash existing drain in single ply roof | EA | 30 | ||
| MISCELLANEOUS TASKS | ||||||
| 0001 | DG | Install new EPDM walkway pad | SF | 200 | ||
| 0001 | DH | Install new concrete paver walkway | SF | 200 | ||
| 0001 | DJ | Fabricate & install plumbers vent extension 2-4" diam | LF | 30 | ||
| 0001 | DK | Remove and re-install existing ventilator | EA | 50 | ||
| 0001 | DL | Remove and re-install rooftop mounted equipment | LB | 2,000 | ||
| 0001 | DM | Fill pitch pans | EA | 20 | ||
| 0001 | DN | Install water & ice shield | SF | 2,000 | ||
| 0001 | DP | Install synthetic rubberized underlayment | SF | 6,000 | ||
| 0001 | DQ | Install #15 felt underlayment, no mopping | SF | 8,000 | ||
| 0001 | DR | Remove existing, deteriorated steel roof decking | SF | 100 | ||
| 0001 | DS | Install new steel roof decking to match existing | SF | 100 | ||
| 0001 | DT | Field paint wood or metal surface | SF | 500 | ||
| 0001 | DU | Apply Siloxane Masonry Water Repellant | 5 Gal | 2 | ||
| MOBILIZATION AND SERVICE CALLS | ||||||
| 0001 | DW | Leak service call | EA | 25 | ||
| 0001 | DX | After hours leak service call | EA | 3 | ||
| 0001 | DY | Extended time on site for service call crew | HR | 30 | ||
| 0001 | DZ | Mobilization of roofing crew | EA | 15 | ||
| 0001 | EA | Mobilization and prep. of asphalt kettle | EA | 5 | ||
| TOTAL | $0.00 |
&C&"Arial,Bold"ROOFING SYSTEMS MAINTENANCE AND REPAIR, ELLSWORTH AFB &R Attachment 28
FA4690-11-B-0101
&C&P OF &N&RGOV ESTIMATE
2013 2ND OPTION
| 2ND OPTION YEAR GOVT EST: 2011-2015 ROOF IDIQ CONTRACT | ||||||
| CLIN | DESCRIPTION | UNIT OF ISSUE | UNIT COST | ESTIMATED QUANTITY | EXTENDED COST | |
| ASPHALT SHINGLES | ||||||
| 0001 | AA | Remove and replace individual shingles; match existing | SF | 500 | ||
| 0001 | AB | Remove shingles, edge metal and underlayment for reroof | SF | 8,000 | ||
| 0001 | AC | Install edge metal for reshingling | LF | 600 | ||
| 0001 | AD | Install laminated architectural shingles | SF | 8,000 | ||
| WOOD | ||||||
| 0001 | AE | Remove and replace deteriorated wood decking | SF | 320 | ||
| 0001 | AF | Install 1/2" CDX plywood sheathing | SF | 6,000 | ||
| 0001 | AG | Install 7/16" OSB sheathing | SF | 6,000 | ||
| 0001 | AH | Install 19/32" OSB sheathing | SF | 4,000 | ||
| 0001 | AJ | Install 19/32" OSB backing for roof membrane flashings | SF | 2,000 | ||
| 0001 | AK | Remove existing wood framing, curbing, blocking and nailers | BF | 3,000 | ||
| 0001 | AL | Install treated wood cants, curbing, blocking and nailers | BF | 5,000 | ||
| 0001 | AM | Install wood framing | BF | 1,000 | ||
| 0001 | AN | Remove existing wood trim & fascia board | SF | 1,000 | ||
| 0001 | AP | Install wood trim and fascia board | BF | 500 | ||
| ROOF INSULATION | ||||||
| 0001 | AQ | Remove existing insulation | BF | 20,000 | ||
| 0001 | AR | Install tapered polyisocyanurate insulation | BF | 5,000 | ||
| 0001 | AS | Install coverboard for PVC or EPDM recover | SF | 4,000 | ||
| 0001 | AT | Install 3" polyisocyanurate insulation | SF | 10,000 | ||
| 0001 | AU | Install 4" polyisocyanurate insulation | SF | 16,000 | ||
| 0001 | AV | Install 1-1/2" fiberglass batt insulation, unfaced | SF | 8,000 | ||
| 0001 | AW | Install R19 fiberglass batt insulation, unfaced | SF | 500 | ||
| 0001 | AX | Install R38 fiberglass batt insulation, unfaced | SF | 2,000 | ||
| 0001 | AY | Install 6 mil polyethelene vapor barrier | SF | 8,000 | ||
| FA4690-11-B-0101 Attachment 29 Page 2 of 4 | ||||||
| METAL ROOFING SYSTEMS | ||||||
| 0001 | AZ | Remove existing metal roof or wall panels and flashings | SF | 200 | ||
| 0001 | BA | Reattach existing loose metal roof or wall panels and flashings | SF | 1,000 | ||
| 0001 | BB | Install corrugated aluminum roof or wall panels, field painted | SF | 100 | ||
| 0001 | BC | Install corrugated steel roof or wall panels, field painted | SF | 100 | ||
| 0001 | BD | Install SSMR system: 20 yr warr. | SF | 8,000 | ||
| 0001 | BE | Install light-gage steel supports for SSMR system | LB | 2,000 | ||
| 0001 | BF | Install SSMR system flashing for rake, eave, sidewall or headwall | LF | 400 | ||
| 0001 | BG | Install SSMR system flashing for ridge, hip or valley | LF | 600 | ||
| 0001 | BH | Install SSMR system snow retention system | LF | 400 | ||
| BUILT-UP ROOFING SYSTEM (BURS) | ||||||
| 0001 | BJ | Spud and remove existing gravel for recover | SF | 1,000 | ||
| 0001 | BK | Sweep and spud gravel for repair, store on roof | SF | 300 | ||
| 0001 | BL | Remove BUR for roof replacement | SF | 15,000 | ||
| 0001 | BM | Install gravel with hot asphalt | SF | 300 | ||
| 0001 | BN | Repair blisters and splits in BUR membrane | SF | 100 | ||
| 0001 | BP | Repair wind scours | SF | 200 | ||
| 0001 | BQ | Install 2-ply mopped roof | SF | 500 | ||
| SINGLE-PLY ROOFING SYSTEMS | ||||||
| 0001 | BR | Install .060" fully-adhered EPDM membrane roof system | SF | 8,000 | ||
| 0001 | BS | Install EPDM flashing system on .060" EPDM | LF | 700 | ||
| 0001 | BT | Install EPDM roof membrane patch | SF | 10 | ||
| 0001 | BU | Install .060" fully-adhered PVC membrane roof system | SF | 10,000 | ||
| 0001 | BW | Install PVC flashing system on .060" PVC | LF | 800 | ||
| 0001 | BX | Install PVC roof membrane patch | SF | 5 | ||
| 0001 | BY | Install water-based, liquid acrylic roofing membrane | SF | 500 | ||
| 0001 | BZ | Install synthetic rubber waterproofing elastomeric sealant | SF | 500 | ||
| 0001 | CA | Install non-woven, spunbound polyester seam reinforcing fabric | SF | 300 | ||
| FA4690-11-B-0101 Attachment 29 Page 3 of 4 | ||||||
| FLASHINGS AND METALS | ||||||
| 0001 | CB | Remove and replace base flashing for repair | LF | 50 | ||
| 0001 | CC | Remove existing base flashing and fiber cants | LF | 200 | ||
| 0001 | CD | Install 2-ply mineral-surfaced modified bitumen base flashing | LF | 200 | ||
| 0001 | CE | Remove, clean, straighten and reinstall sheet metal flashing | LF | 800 | ||
| 0001 | CF | Sawcut for reglet in masonry or concrete | LF | 200 | ||
| 0001 | CG | Install Kynar-finished steel counter flashing | LF | 1,000 | ||
| 0001 | CH | Remove existing sheet metal fascia, coping and flashing | SF | 2,000 | ||
| 0001 | CJ | Install 24 ga. Kynar-finished fascia, coping and flashing | SF | 3,000 | ||
| 0001 | CK | Install 24 ga. Kynar-finished soffit panel, plain or vented | SF | 800 | ||
| 0001 | CL | Increased cost for vented ridge flashing vs non-vented | LF | 300 | ||
| 0001 | CM | Install 24 ga. galvanized steel continous cleat | LF | 1,000 | ||
| 0001 | CN | Install pipe penetration flashing: 0 to 6" dia. | EA | 40 | ||
| 0001 | CP | Install pipe penetration flashing: 6"+ to 12" dia. | EA | 5 | ||
| GUTTERS AND DOWNSPOUTS | ||||||
| 0001 | CQ | Clean out gutters and downspouts | LF | 300 | ||
| 0001 | CR | Remove existing gutters and downspouts | LF | 500 | ||
| 0001 | CS | Install Kynar pre-finished sheet metal gutters | LF | 1,000 | ||
| 0001 | CT | Install Kynar pre-finished sheet metal downspouts | LF | 800 | ||
| 0001 | CU | Install Kynar pre-finishedsheet metal roof scupper box | EA | 5 | ||
| 0001 | CV | Install precast concrete splash blocks | EA | 20 | ||
| SEALANTS | ||||||
| 0001 | CW | Remove existing backer rod and sealant, clean joint for reseal | LF | 300 | ||
| 0001 | CX | Install backer rod and polyurethane sealant: 0 to 1/2" wide | LF | 150 | ||
| 0001 | CY | Install backer rod and polyurethane sealant: >1/2" to 3/4" wide | LF | 100 | ||
| 0001 | CZ | Install backer rod and polyurethane sealant: >3/4" wide | LF | 50 | ||
| 0001 | DA | Install polyurethane sealant, misc. joints and seams | LB | 150 | ||
| 0001 | DB | Install butyl sealant, misc. joints and seams: no backer rod | LB | 100 | ||
| FA4690-11-B-0101 Attachment 29 Page 4 of 4 | ||||||
| ROOF DRAINS | ||||||
| 0001 | DC | Clean in and around roof drains | EA | 15 | ||
| 0001 | DD | Install new clamp ring and bolts | EA | 20 | ||
| 0001 | DE | Install new strainer basket | EA | 10 | ||
| 0001 | DF | Re-flash existing drain in single ply roof | EA | 30 | ||
| MISCELLANEOUS TASKS | ||||||
| 0001 | DG | Install new EPDM walkway pad | SF | 200 | ||
| 0001 | DH | Install new concrete paver walkway | SF | 200 | ||
| 0001 | DJ | Fabricate & install plumbers vent extension 2-4" diam | LF | 30 | ||
| 0001 | DK | Remove and re-install existing ventilator | EA | 50 | ||
| 0001 | DL | Remove and re-install rooftop mounted equipment | LB | 2,000 | ||
| 0001 | DM | Fill pitch pans | EA | 20 | ||
| 0001 | DN | Install water & ice shield | SF | 2,000 | ||
| 0001 | DP | Install synthetic rubberized underlayment | SF | 6,000 | ||
| 0001 | DQ | Install #15 felt underlayment, no mopping | SF | 8,000 | ||
| 0001 | DR | Remove existing, deteriorated steel roof decking | SF | 100 | ||
| 0001 | DS | Install new steel roof decking to match existing | SF | 100 | ||
| 0001 | DT | Field paint wood or metal surface | SF | 500 | ||
| 0001 | DU | Apply Siloxane Masonry Water Repellant | 5 Gal | 2 | ||
| MOBILIZATION AND SERVICE CALLS | ||||||
| 0001 | DW | Leak service call | EA | 25 | ||
| 0001 | DX | After hours leak service call | EA | 3 | ||
| 0001 | DY | Extended time on site for service call crew | HR | 30 | ||
| 0001 | DZ | Mobilization of roofing crew | EA | 15 | ||
| 0001 | EA | Mobilization and prep. of asphalt kettle | EA | 5 | ||
| TOTAL | $0.00 |
&C&"Arial,Bold"ROOFING SYSTEMS MAINTENANCE AND REPAIR, ELLSWORTH AFB &R Attachment 28
FA4690-11-B-0101
&C&P OF &N&RGOV ESTIMATE
2014 3RD OPTION
| 3RD OPTION YEAR GOVT EST: 2011-2015 ROOF IDIQ CONTRACT | ||||||
| CLIN | DESCRIPTION | UNIT OF ISSUE | UNIT COST | ESTIMATED QUANTITY | EXTENDED COST | |
| ASPHALT SHINGLES | ||||||
| 0001 | AA | Remove and replace individual shingles; match existing | SF | 500 | ||
| 0001 | AB | Remove shingles, edge metal and underlayment for reroof | SF | 8,000 | ||
| 0001 | AC | Install edge metal for reshingling | LF | 600 | ||
| 0001 | AD | Install laminated architectural shingles | SF | 8,000 | ||
| WOOD | ||||||
| 0001 | AE | Remove and replace deteriorated wood decking | SF | 320 | ||
| 0001 | AF | Install 1/2" CDX plywood sheathing | SF | 6,000 | ||
| 0001 | AG | Install 7/16" OSB sheathing | SF | 6,000 | ||
| 0001 | AH | Install 19/32" OSB sheathing | SF | 4,000 | ||
| 0001 | AJ | Install 19/32" OSB backing for roof membrane flashings | SF | 2,000 | ||
| 0001 | AK | Remove existing wood framing, curbing, blocking and nailers | BF | 3,000 | ||
| 0001 | AL | Install treated wood cants, curbing, blocking and nailers | BF | 5,000 | ||
| 0001 | AM | Install wood framing | BF | 1,000 | ||
| 0001 | AN | Remove existing wood trim & fascia board | SF | 1,000 | ||
| 0001 | AP | Install wood trim and fascia board | BF | 500 | ||
| ROOF INSULATION | ||||||
| 0001 | AQ | Remove existing insulation | BF | 20,000 | ||
| 0001 | AR | Install tapered polyisocyanurate insulation | BF | 5,000 | ||
| 0001 | AS | Install coverboard for PVC or EPDM recover | SF | 4,000 | ||
| 0001 | AT | Install 3" polyisocyanurate insulation | SF | 10,000 | ||
| 0001 | AU | Install 4" polyisocyanurate insulation | SF | 16,000 | ||
| 0001 | AV | Install 1-1/2" fiberglass batt insulation, unfaced | SF | 8,000 | ||
| 0001 | AW | Install R19 fiberglass batt insulation, unfaced | SF | 500 | ||
| 0001 | AX | Install R38 fiberglass batt insulation, unfaced | SF | 2,000 | ||
| 0001 | AY | Install 6 mil polyethelene vapor barrier | SF | 8,000 | ||
| FA4690-11-B-0101 Attachment 29 Page 2 of 4 | ||||||
| METAL ROOFING SYSTEMS | ||||||
| 0001 | AZ | Remove existing metal roof or wall panels and flashings | SF | 200 | ||
| 0001 | BA | Reattach existing loose metal roof or wall panels and flashings | SF | 1,000 | ||
| 0001 | BB | Install corrugated aluminum roof or wall panels, field painted | SF | 100 | ||
| 0001 | BC | Install corrugated steel roof or wall panels, field painted | SF | 100 | ||
| 0001 | BD | Install SSMR system: 20 yr warr. | SF | 8,000 | ||
| 0001 | BE | Install light-gage steel supports for SSMR system | LB | 2,000 | ||
| 0001 | BF | Install SSMR system flashing for rake, eave, sidewall or headwall | LF | 400 | ||
| 0001 | BG | Install SSMR system flashing for ridge, hip or valley | LF | 600 | ||
| 0001 | BH | Install SSMR system snow retention system | LF | 400 | ||
| BUILT-UP ROOFING SYSTEM (BURS) | ||||||
| 0001 | BJ | Spud and remove existing gravel for recover | SF | 1,000 | ||
| 0001 | BK | Sweep and spud gravel for repair, store on roof | SF | 300 | ||
| 0001 | BL | Remove BUR for roof replacement | SF | 15,000 | ||
| 0001 | BM | Install gravel with hot asphalt | SF | 300 | ||
| 0001 | BN | Repair blisters and splits in BUR membrane | SF | 100 | ||
| 0001 | BP | Repair wind scours | SF | 200 | ||
| 0001 | BQ | Install 2-ply mopped roof | SF | 500 | ||
| SINGLE-PLY ROOFING SYSTEMS | ||||||
| 0001 | BR | Install .060" fully-adhered EPDM membrane roof system | SF | 8,000 | ||
| 0001 | BS | Install EPDM flashing system on .060" EPDM | LF | 700 | ||
| 0001 | BT | Install EPDM roof membrane patch | SF | 10 | ||
| 0001 | BU | Install .060" fully-adhered PVC membrane roof system | SF | 10,000 | ||
| 0001 | BW | Install PVC flashing system on .060" PVC | LF | 800 | ||
| 0001 | BX | Install PVC roof membrane patch | SF | 5 | ||
| 0001 | BY | Install water-based, liquid acrylic roofing membrane | SF | 500 | ||
| 0001 | BZ | Install synthetic rubber waterproofing elastomeric sealant | SF | 500 | ||
| 0001 | CA | Install non-woven, spunbound polyester seam reinforcing fabric | SF | 300 | ||
| FA4690-11-B-0101 Attachment 29 Page 3 of 4 | ||||||
| FLASHINGS AND METALS | ||||||
| 0001 | CB | Remove and replace base flashing for repair | LF | 50 | ||
| 0001 | CC | Remove existing base flashing and fiber cants | LF | 200 | ||
| 0001 | CD | Install 2-ply mineral-surfaced modified bitumen base flashing | LF | 200 | ||
| 0001 | CE | Remove, clean, straighten and reinstall sheet metal flashing | LF | 800 | ||
| 0001 | CF | Sawcut for reglet in masonry or concrete | LF | 200 | ||
| 0001 | CG | Install Kynar-finished steel counter flashing | LF | 1,000 | ||
| 0001 | CH | Remove existing sheet metal fascia, coping and flashing | SF | 2,000 | ||
| 0001 | CJ | Install 24 ga. Kynar-finished fascia, coping and flashing | SF | 3,000 | ||
| 0001 | CK | Install 24 ga. Kynar-finished soffit panel, plain or vented | SF | 800 | ||
| 0001 | CL | Increased cost for vented ridge flashing vs non-vented | LF | 300 | ||
| 0001 | CM | Install 24 ga. galvanized steel continous cleat | LF | 1,000 | ||
| 0001 | CN | Install pipe penetration flashing: 0 to 6" dia. | EA | 40 | ||
| 0001 | CP | Install pipe penetration flashing: 6"+ to 12" dia. | EA | 5 | ||
| GUTTERS AND DOWNSPOUTS | ||||||
| 0001 | CQ | Clean out gutters and downspouts | LF | 300 | ||
| 0001 | CR | Remove existing gutters and downspouts | LF | 500 | ||
| 0001 | CS | Install Kynar pre-finished sheet metal gutters | LF | 1,000 | ||
| 0001 | CT | Install Kynar pre-finished sheet metal downspouts | LF | 800 | ||
| 0001 | CU | Install Kynar pre-finishedsheet metal roof scupper box | EA | 5 | ||
| 0001 | CV | Install precast concrete splash blocks | EA | 20 | ||
| SEALANTS | ||||||
| 0001 | CW | Remove existing backer rod and sealant, clean joint for reseal | LF | 300 | ||
| 0001 | CX | Install backer rod and polyurethane sealant: 0 to 1/2" wide | LF | 150 | ||
| 0001 | CY | Install backer rod and polyurethane sealant: >1/2" to 3/4" wide | LF | 100 | ||
| 0001 | CZ | Install backer rod and polyurethane sealant: >3/4" wide | LF | 50 | ||
| 0001 | DA | Install polyurethane sealant, misc. joints and seams | LB | 150 | ||
| 0001 | DB | Install butyl sealant, misc. joints and seams: no backer rod | LB | 100 | ||
| FA4690-11-B-0101 Attachment 29 Page 4 of 4 | ||||||
| ROOF DRAINS | ||||||
| 0001 | DC | Clean in and around roof drains | EA | 15 | ||
| 0001 | DD | Install new clamp ring and bolts | EA | 20 | ||
| 0001 | DE | Install new strainer basket | EA | 10 | ||
| 0001 | DF | Re-flash existing drain in single ply roof | EA | 30 | ||
| MISCELLANEOUS TASKS | ||||||
| 0001 | DG | Install new EPDM walkway pad | SF | 200 | ||
| 0001 | DH | Install new concrete paver walkway | SF | 200 | ||
| 0001 | DJ | Fabricate & install plumbers vent extension 2-4" diam | LF | 30 | ||
| 0001 | DK | Remove and re-install existing ventilator | EA | 50 | ||
| 0001 | DL | Remove and re-install rooftop mounted equipment | LB | 2,000 | ||
| 0001 | DM | Fill pitch pans | EA | 20 | ||
| 0001 | DN | Install water & ice shield | SF | 2,000 | ||
| 0001 | DP | Install synthetic rubberized underlayment | SF | 6,000 | ||
| 0001 | DQ | Install #15 felt underlayment, no mopping | SF | 8,000 | ||
| 0001 | DR | Remove existing, deteriorated steel roof decking | SF | 100 | ||
| 0001 | DS | Install new steel roof decking to match existing | SF | 100 | ||
| 0001 | DT | Field paint wood or metal surface | SF | 500 | ||
| 0001 | DU | Apply Siloxane Masonry Water Repellant | 5 Gal | 2 | ||
| MOBILIZATION AND SERVICE CALLS | ||||||
| 0001 | DW | Leak service call | EA | 25 | ||
| 0001 | DX | After hours leak service call | EA | 3 | ||
| 0001 | DY | Extended time on site for service call crew | HR | 30 | ||
| 0001 | DZ | Mobilization of roofing crew | EA | 15 | ||
| 0001 | EA | Mobilization and prep. of asphalt kettle | EA | 5 | ||
| TOTAL | $0.00 |
&C&"Arial,Bold"ROOFING SYSTEMS MAINTENANCE AND REPAIR, ELLSWORTH AFB &R Attachment 28
FA4690-11-B-0101
&C&P OF &N&RGOV ESTIMATE
2015 4TH OPTION
| 4TH OPTION YEAR GOVT EST: 2011-2015 ROOF IDIQ CONTRACT | ||||||
| CLIN | DESCRIPTION | UNIT OF ISSUE | UNIT COST | ESTIMATED QUANTITY | EXTENDED COST | |
| ASPHALT SHINGLES | ||||||
| 0001 | AA | Remove and replace individual shingles; match existing | SF | $4.26 | 500 | |
| 0001 | AB | Remove shingles, edge metal and underlayment for reroof | SF | $0.73 | 8,000 | |
| 0001 | AC | Install edge metal for reshingling | LF | $1.46 | 600 | |
| 0001 | AD | Install laminated architectural shingles | SF | $2.10 | 8,000 | |
| WOOD | ||||||
| 0001 | AE | Remove and replace deteriorated wood decking | SF | $3.76 | 320 | |
| 0001 | AF | Install 1/2" CDX plywood sheathing | SF | $3.21 | 6,000 | |
| 0001 | AG | Install 7/16" OSB sheathing | SF | $2.07 | 6,000 | |
| 0001 | AH | Install 19/32" OSB sheathing | SF | $2.43 | 4,000 | |
| 0001 | AJ | Install 19/32" OSB backing for roof membrane flashings | SF | $3.16 | 2,000 | |
| 0001 | AK | Remove existing wood framing, curbing, blocking and nailers | BF | $1.10 | 3,000 | |
| 0001 | AL | Install treated wood cants, curbing, blocking and nailers | BF | $3.64 | 5,000 | |
| 0001 | AM | Install wood framing | BF | $4.14 | 1,000 | |
| 0001 | AN | Remove existing wood trim & fascia board | SF | $1.52 | 1,000 | |
| 0001 | AP | Install wood trim and fascia board | BF | $4.87 | 500 | |
| ROOF INSULATION | ||||||
| 0001 | AQ | Remove existing insulation | BF | 20,000 | ||
| 0001 | AR | Install tapered polyisocyanurate insulation | BF | 5,000 | ||
| 0001 | AS | Install coverboard for PVC or EPDM recover | SF | 4,000 | ||
| 0001 | AT | Install 3" polyisocyanurate insulation | SF | 10,000 | ||
| 0001 | AU | Install 4" polyisocyanurate insulation | SF | 16,000 | ||
| 0001 | AV | Install 1-1/2" fiberglass batt insulation, unfaced | SF | 8,000 | ||
| 0001 | AW | Install R19 fiberglass batt insulation, unfaced | SF | 500 | ||
| 0001 | AX | Install R38 fiberglass batt insulation, unfaced | SF | 2,000 | ||
| 0001 | AY | Install 6 mil polyethelene vapor barrier | SF | 8,000 | ||
| FA4690-11-B-0101 Attachment 29 Page 2 of 4 | ||||||
| METAL ROOFING SYSTEMS | ||||||
| 0001 | AZ | Remove existing metal roof or wall panels and flashings | SF | 200 | ||
| 0001 | BA | Reattach existing loose metal roof or wall panels and flashings | SF | 1,000 | ||
| 0001 | BB | Install corrugated aluminum roof or wall panels, field painted | SF | 100 | ||
| 0001 | BC | Install corrugated steel roof or wall panels, field painted | SF | 100 | ||
| 0001 | BD | Install SSMR system: 20 yr warr. | SF | 8,000 | ||
| 0001 | BE | Install light-gage steel supports for SSMR system | LB | 2,000 | ||
| 0001 | BF | Install SSMR system flashing for rake, eave, sidewall or headwall | LF | 400 | ||
| 0001 | BG | Install SSMR system flashing for ridge, hip or valley | LF | 600 | ||
| 0001 | BH | Install SSMR system snow retention system | LF | 400 | ||
| BUILT-UP ROOFING SYSTEM (BURS) | ||||||
| 0001 | BJ | Spud and remove existing gravel for recover | SF | 1,000 | ||
| 0001 | BK | Sweep and spud gravel for repair, store on roof | SF | 300 | ||
| 0001 | BL | Remove BUR for roof replacement | SF | 15,000 | ||
| 0001 | BM | Install gravel with hot asphalt | SF | 300 | ||
| 0001 | BN | Repair blisters and splits in BUR membrane | SF | 100 | ||
| 0001 | BP | Repair wind scours | SF | 200 | ||
| 0001 | BQ | Install 2-ply mopped roof | SF | 500 | ||
| SINGLE-PLY ROOFING SYSTEMS | ||||||
| 0001 | BR | Install .060" fully-adhered EPDM membrane roof system | SF | 8,000 | ||
| 0001 | BS | Install EPDM flashing system on .060" EPDM | LF | 700 | ||
| 0001 | BT | Install EPDM roof membrane patch | SF | 10 | ||
| 0001 | BU | Install .060" fully-adhered PVC membrane roof system | SF | 10,000 | ||
| 0001 | BW | Install PVC flashing system on .060" PVC | LF | 800 | ||
| 0001 | BX | Install PVC roof membrane patch | SF | 5 | ||
| 0001 | BY | Install water-based, liquid acrylic roofing membrane | SF | 500 | ||
| 0001 | BZ | Install synthetic rubber waterproofing elastomeric sealant | SF | 500 | ||
| 0001 | CA | Install non-woven, spunbound polyester seam reinforcing fabric | SF | 300 | ||
| FA4690-11-B-0101 Attachment 29 Page 3 of 4 | ||||||
| FLASHINGS AND METALS | ||||||
| 0001 | CB | Remove and replace base flashing for repair | LF | 50 | ||
| 0001 | CC | Remove existing base flashing and fiber cants | LF | 200 | ||
| 0001 | CD | Install 2-ply mineral-surfaced modified bitumen base flashing | LF | 200 | ||
| 0001 | CE | Remove, clean, straighten and reinstall sheet metal flashing | LF | 800 | ||
| 0001 | CF | Sawcut for reglet in masonry or concrete | LF | 200 | ||
| 0001 | CG | Install Kynar-finished steel counter flashing | LF | 1,000 | ||
| 0001 | CH | Remove existing sheet metal fascia, coping and flashing | SF | 2,000 | ||
| 0001 | CJ | Install 24 ga. Kynar-finished fascia, coping and flashing | SF | 3,000 | ||
| 0001 | CK | Install 24 ga. Kynar-finished soffit panel, plain or vented | SF | 800 | ||
| 0001 | CL | Increased cost for vented ridge flashing vs non-vented | LF | 300 | ||
| 0001 | CM | Install 24 ga. galvanized steel continous cleat | LF | 1,000 | ||
| 0001 | CN | Install pipe penetration flashing: 0 to 6" dia. | EA | 40 | ||
| 0001 | CP | Install pipe penetration flashing: 6"+ to 12" dia. | EA | 5 | ||
| GUTTERS AND DOWNSPOUTS | ||||||
| 0001 | CQ | Clean out gutters and downspouts | LF | 300 | ||
| 0001 | CR | Remove existing gutters and downspouts | LF | 500 | ||
| 0001 | CS | Install Kynar pre-finished sheet metal gutters | LF | 1,000 | ||
| 0001 | CT | Install Kynar pre-finished sheet metal downspouts | LF | 800 | ||
| 0001 | CU | Install Kynar pre-finishedsheet metal roof scupper box | EA | 5 | ||
| 0001 | CV | Install precast concrete splash blocks | EA | 20 | ||
| SEALANTS | ||||||
| 0001 | CW | Remove existing backer rod and sealant, clean joint for reseal | LF | 300 | ||
| 0001 | CX | Install backer rod and polyurethane sealant: 0 to 1/2" wide | LF | 150 | ||
| 0001 | CY | Install backer rod and polyurethane sealant: >1/2" to 3/4" wide | LF | 100 | ||
| 0001 | CZ | Install backer rod and polyurethane sealant: >3/4" wide | LF | 50 | ||
| 0001 | DA | Install polyurethane sealant, misc. joints and seams | LB | 150 | ||
| 0001 | DB | Install butyl sealant, misc. joints and seams: no backer rod | LB | 100 | ||
| FA4690-11-B-0101 Attachment 29 Page 4 of 4 | ||||||
| ROOF DRAINS | ||||||
| 0001 | DC | Clean in and around roof drains | EA | 15 | ||
| 0001 | DD | Install new clamp ring and bolts | EA | 20 | ||
| 0001 | DE | Install new strainer basket | EA | 10 | ||
| 0001 | DF | Re-flash existing drain in single ply roof | EA | 30 | ||
| MISCELLANEOUS TASKS | ||||||
| 0001 | DG | Install new EPDM walkway pad | SF | 200 | ||
| 0001 | DH | Install new concrete paver walkway | SF | 200 | ||
| 0001 | DJ | Fabricate & install plumbers vent extension 2-4" diam | LF | 30 | ||
| 0001 | DK | Remove and re-install existing ventilator | EA | 50 | ||
| 0001 | DL | Remove and re-install rooftop mounted equipment | LB | 2,000 | ||
| 0001 | DM | Fill pitch pans | EA | 20 | ||
| 0001 | DN | Install water & ice shield | SF | 2,000 | ||
| 0001 | DP | Install synthetic rubberized underlayment | SF | 6,000 | ||
| 0001 | DQ | SF | 8,000 | |||
| 0001 | DR | Remove existing, deteriorated steel roof decking | SF | 100 | ||
| 0001 | DS | Install new steel roof decking to match existing | SF | 100 | ||
| 0001 | DT | Field paint wood or metal surface | SF | 500 | ||
| 0001 | DU | Apply Siloxane Masonry Water Repellant | 5 Gal | 2 | ||
| MOBILIZATION AND SERVICE CALLS | ||||||
| 0001 | DW | Leak service call | EA | 25 | ||
| 0001 | DX | After hours leak service call | EA | 3 | ||
| 0001 | DY | Extended time on site for service call crew | HR | 30 | ||
| 0001 | DZ | Mobilization of roofing crew | EA | 15 | ||
| 0001 | EA | Mobilization and prep. of asphalt kettle | EA | 5 | ||
| TOTAL | $0.00 |
&C&"Arial,Bold"ROOFING SYSTEMS MAINTENANCE AND REPAIR, ELLSWORTH AFB &R Attachment 28
FA4690-11-B-0101
File details come from the government source that posted it. Updated .