NEW_Seed_Project.pdf
PDF 537 KB Posted
- Attached to
- Protective Coating ID/IQ
- Solicitation number
- FA4661-19-R-A001
About this file
This is the NEW seed project to implement into proposals.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Drawing_9109_with_Dimensions.pdf | ||
| 02_Drawings_Combined.pdf | ||
| 02_-_SOW_Floors_7008_new_contract.pdf | ||
| PC_Q&A.pdf | ||
| 04_-_7008_Overall_Building.pdf | ||
| Solicitation_-_FA466119RA001.pdf | ||
| 03_-_7008_Room_Floors.pdf | ||
| Attachment_6_-_Past_Performance_Information_Document.docx | DOCX document | |
| Solicitation_-_FA466119RA001.pdf | ||
| Attachment_2_-_PPQ.pdf | ||
| Attachment_3_-_Pricing_Schedule.xlsx | XLSX spreadsheet | |
| Attachment_7_-_Subcontractor_Consent_Letter.docx | DOCX document | |
| Attachment_4_-_SOW.docx | DOCX document | |
| Attachment_5_-_Wage_Determination.pdf | ||
| Attachment_1_-_Question_Submission_Form.doc | DOC document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCOPE OF WORK
Requestor: Mark Young Date: 2 Aug 2017 Request DO Number: 00XX
Office Symbol: 7CES/CEOES Duty Phone: 6-2757
Contract: Protective Coating Maintenance Contract Number: TBD Contractor: TBD
Work Request Title: Seed Project for New Protective Coating Contract – Misc. Base Repairs
ECD 90 Days Facility Number (s): Listed Below
Work Order Number (s): Listed Below
DETAILS OF REQUESTED ITEM:
1. SCOPE: The work covered by this project consists of the Contractor furnishing all layout, survey, plant, labor, supervision, quality control, materials, equipment, machines, tools, appliances, services, supplies, and incidentals necessary to perform all operations as outlined under the FA4661-09-R-0001 Protective
Coatings Maintenance contract.
1.1 Contractor shall Patch & Paint interior Walls at Bldg. 9109, Designate no parking areas by Bldg. 704, Install DO NOT ENTER signs across from Bldg. 5005, Install Maintained By signs by A/C in Air Park, Install sign for Marketing Office and correct some missing or too small street signs.
1.2 FP 1002461 - Paint Interior Walls Bldg. 9109: Contractor shall prepare and paint interior walls and all doors at Bldg. 9109. Contractor shall patch all existing holes the interior walls identified in the attached drawings. Once walls have been patched contractor shall apply one coat of primer and two coats of Sherwin Williams paint #SW 7103, whitetail in semi-gloss paint. Contractor shall also paint all doors and frames in the building to include the exterior doors. Doors and frames shall be painted dark brown.
1.3 WT 2344898 - Hatch Parking Spots by Bldg. 7040: Contractor shall paint hatch marks in the parking lot next to Bldg. 7040. See attached drawing for location. The Traffic Safety Council has determined that two parking spots closest to 2nd Street and Herk Drive are blocking the view of vehicles stopping at the stop sign. Spots need to be hatched to prevent people from parking there. Contractor shall power wash the area to remove any grit or grime in the area. Once dried contractor shall paint 4” white line 24” apart at a 45 degree angle to existing lines. Paint color shall be white.
1.4 WT 2706289 - Install "DO NOT ENTER" Sign at Parking Lot Across from Bldg. 5005: Contractor shall install a “DO NOT ENTER” sign at the parking lot across from Bldg. 5005. See attached slide for location of sign. Sign shall be a R5-1 sign measuring 30” X 30” and be High Intensity Prismatic Reflective Aluminum. Sign shall be installed on a galvanized metal round post and meet MUTCD requirements.
1.5 WT 2707955 - Install “Maintained By” signs in the Air Park: Contractor shall create and install two (2)
“National Museum” and thirty four (34) “Maintained By” signs in the Air Park along Arnold Ave.
Contractor shall create and install two (2) “National Museum” metal signs that are 12” X 12” with rounded corners. Background of signs shall be scotch lite brown with ¾” white lettering. Signs shall read “ALL AIRCRAFT ON LOAN FROM THE NATIONAL MUSEUM OF THE UNITED STATES AIR FORCE”. Signs shall be pole mounted in front of the F-15A and F-111A aircraft. See drawings for sign layout and location.
Contractor shall create and install thirty four (34) “Maintained By” signs that are 12” X 4” with rounded corners. Background of signs shall be scotch lite brown with ¾” white lettering. Signs shall read “MAINTAINED BY” on the top line and the designated office listed on the second line. These signs shall be mounted under the existing “National Museum” signs. See drawings for sign layout and location.
1.6 WT 3844801 - Install Organization Sign at the Marketing Office: Contractor shall install a “DO NOT
ENTER” sign at the parking lot across from Bldg. 5005. See attached slide for location of sign. Sign shall be a R5-1 sign measuring 30” X 30” and be High Intensity Prismatic Reflective Aluminum. Sign shall be installed on a galvanized metal round post and meet MUTCD requirements.
1.7 WT 4516341 - Replace Missing/Smaller Street Signs: Contractor shall remove and replace stop signs on Ave B and replace Barrier sign at the Arnold Gate inbound lanes.
Contractor shall remove the existing 30” X 30” STOP signs on both sides of Ave B where it Meets 3rd Street/Ave and replace them with new 36” X 36” R1-1 STOP signs. Signs shall be High Intensity
Prismatic Reflective Aluminum. See attached drawings for location.
Contractor shall install a new W3-3A barrier signs on the side of the road on the inbound lane of Arnold gate. Signs shall be High Intensity Prismatic Reflective Aluminum. The old sign is missing. See attached drawings for location.