FA4659-10-R-0043-0001.doc

DOC document 39 KB Posted

Attached to
BCE B410, Construct Mechanical Room & Repair HVAC
Solicitation number
FA4659-10-R-0043_Synopsis
Issued by

About this file

Amendment to incorporate changes provided by the project designers.

View the file

Other files

File Type Posted
Amendment 0004 Due Date Extension.docx DOCX document
Amendment 0003.rtf RTF text file
FA4659-10-R-0043-0002.doc DOC document
Atth 1 - Technical Specs.pdf PDF
Atth 5 - Financial Institution Reference Sheet.doc DOC document
Atth 6 - Climatological Data.pdf PDF
Atth 2 - Drawings.pdf PDF
Solicitation FA4659-10-R-0043.doc DOC document
410 RFP Letter.pdf PDF
Atth 4 - Past Performance Questionnaire.doc DOC document
Atth 3 - Submittal Schedule.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

Summary of changes:

a. Section 04 20 00 Page 8, Lines 50-59, and Page 04 20 00-9, Lines 1 and 2. Delete in their entirety and replace with the following:

1. At cavity wall construction, build flashing into masonry construction as indicated on the drawings. Stop flashing 1/4 inch back from outside face of wall and adhere flashing to substrate below.

2. At brick veneer/stud wall construction, extend flashing up behind rigid wall insulation and seal top edge with mastic as shown on the Drawings.

3. At lintels and shelf angles, extend flashing a minimum of 4 inches into masonry at each end. At heads and sills, extend flashing 4 inches at ends and turn flashing up not less than 2 inches to form a pan.

4. Care shall be taken not to puncture flashing material and to keep cavity completely free of mortar droppings. Joints shall be avoided to the maximum extent possible, but where they occur, they shall be lapped a minimum of 6-inches and sealed with the manufacturer’s recommended joint adhesive. All flashing steps and corner turns shall be thoroughly sealed. Gaps in thru-wall flashing or unsealed lapped joints will not be acceptable.

b. Section 04 20 00 Page 7, Line 50. Delete the following: “at exterior steel stud/brick veneer walls”.

c. Section 32 16 13, Page 1, Lines 15-19. Delete in their entirety.

(End of Summary of Changes)