This document contains the results of an asbestos and lead bulk sampling report for buildings 636 and 714 at Dover Air Force Base, as well as details of a related federal contract solicitation to renovate building 636.

The bulk sampling report identifies the materials tested, locations, quantities, and test results for asbestos and lead at each building. No asbestos was found above 1% in any materials tested. Lead was detected above HUD standards in white paint on an I-beam and mechanical room components at building 714. The solicitation seeks contractors to provide design, labor, materials, and equipment to renovate building 636 in accordance with the statement of work dated February 20, 2020. Renovations include installing a natural gas line, boiler, furnace and air conditioning unit, modifying sanitary sewer lines, renovating a restroom, restoring floors, and demolishing building 632. The contracting agency is the Department of the Air Force Air Mobility Command.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Mr. Steven Seip September 30, 2019

GS-14 USAF AMC 436 CES/CEIE

Dover Air Force Base, Dover, DE 19902

RE: Asbestos & Lead Bulk Sampling at the Dover Air Force Base, Buildings #636 & #714

BEA #897519E

On September 13th, 2019 Batta Environmental Associates, Inc. (BEA) performed bulk sampling for suspect asbestos containing materials (ACM) in Building 714 and 632 and bulk sampling for suspect lead based paint (LBP) in Building 714.

The bulk sampling was conducted by Nicholas Mariconda, an EPA certified building inspector (EHSBIR 190205-00008) from Batta Environmental Associates, Inc. (BEA) who is experienced in identifying and sampling suspect ACM and collecting bulk samples of paint for analysis for lead.

All samples collected were analyzed at Batta Laboratories, LLC, using either Polarized Light Microscopy (PLM) methods for suspect ACM samples or using the SW846 chips by flame analytical method for paint samples. A total of nineteen (19) PLM samples were collected and two (2) paint samples.

The following table summarizes the PLM samples collected. No materials were found to contain asbestos in amounts greater than 1 % (NAD = No Asbestos Detected).

DOVER AIR FORCE BASE – BUILDING 632

Material Location % ACM Category Condition Quantity

Drywall Building 632-throughout NAD NA NA NA

Joint Compound Building 632-throughout NAD NA NA NA

12”x12” Floor Tile Building 632-throughout NAD NA NA NA

Mastic Building 632-throughout NAD NA NA NA

Roof Shingles Building 632-exterior roof NAD NA NA NA

Roof Felt Building 632-exterior roof NAD NA NA NA

2’x2’ Ceiling Tile Building 632-throughout NAD NA NA NA

Window Glazing Building 632-exterior windows NAD NA NA NA

DOVER AIR FORCE BASE – BUILDING 714

Material Location % ACM Category Condition Quantity

Glue Dots Building 714 West Tier Office NAD NA NA NA

DNREC and the US Environmental Protection Agency – Region III, require notification of intent to renovate or demolish when asbestos is present. Notification must be sent at least 10 working days prior to the start of any construction activities. The general contractor should also keep a copy of these sampling results at the construction site during the entire construction project as proof of compliance with 40 CFR 61 (NESHAP).

The following table provides the results of testing for lead based paint in the Alternate EOC

Area of Building 714, and in the Dover Air Force Base, Dover, DE 19902. Samples collected those were greater than 0.50% by weight are defined as LBP under the Department of Housing and Urban Development (HUD).

Paint Color

Location(s) Component Substrate Condition Pb % by Weight

White I Beam Paint (714) Beam Metal Good 3.5 white Mechanical Room Paint (714) Electrical Equipment

Metal Good 0.24

LBP is defined by HUD as paint that contains lead in concentrations greater than one milligram per square centimeter (1.0 mg/cm2) or 0.50% by weight. Lead in paint at any level is regulated under OSHA 29 CFR 1926.62 which applies to all construction work where an employee may be occupationally exposed to lead which includes the demolition or salvage of structures and torch cutting where lead or materials containing lead are present.

Please find attached to this letter the certificates of analysis, chain of custodies, and field paperwork for the Asbestos and Lead Paint Bulk Sampling in Buildings 636 and 714 of the Dover

Air Force Base, Dover, DE 19902.

If you should have any questions please contact me at any time.

Sincerely

BATTA ENVIRONMENTAL ASSOCIATES, INC.

Jeffrey M. Kuntz, Senior Project Manager Batta Laboratories, LLC Batta Technologies, LLC EHS Training Institute(Batta, LLC).

302-737-3376 x. 105 (Office), 302-598-0058 (Cell), Jeff.Kuntz@BattaEnv.com mailto:Jeff.Kuntz@BattaEnv.com

897519E-Bldg 714-636-Report-JMK