Attachment_5_B550_Form_66.xlsx
XLSX spreadsheet 54 KB Posted
- Attached to
- HVAC Interior Renovation/Bldg 550 Federal contract opportunity
- Solicitation number
- FA302218R0007
About this file
Attachment #5: B550 Form 66
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA302218R0007_Conformed_Copy.pdf | ||
| FA302218R0007_Amendment_1.pdf | ||
| UEQ_B550-Questions_and_Answers_20180723.pdf | ||
| B550_DBSOW_20180721.pdf | ||
| Site_Visit_Sign_In_Sheet.pdf | ||
| Attachment_2_B550_Drawings.pdf | ||
| Attachment_3_Wage_Determination.pdf | ||
| Attachment_6_Contractor_Insurance_Certification.pdf | ||
| Attachment_1_-B550_DBSOW_21_June_2018.pdf | ||
| FA302218R0007,_B550_HVAC_Interior_Renovation.pdf | ||
| Attachment_4_DD_1354.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
General
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| 1 | Work Plan | BASIC | 4 | ||||||||||||||||
| 2 | Demolition Plan | BASIC | 4 | ||||||||||||||||
| 3 | Construction Plan | BASIC | 4 | ||||||||||||||||
| 4 | As-Built Drawings | BASIC | 4 | ||||||||||||||||
| 5 | Progress Schedule | BASIC | 4 | ||||||||||||||||
| 6 | Guarantees and Warranties | BASIC | 4 |
Environmental
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| 7 | Appropriate MSDS | BASIC | 4 | ||||||||||||||||
| 8 | Hazardous Waste Report | BASIC | 4 | ||||||||||||||||
| 9 | Hazardous Material Report (AF Form 3000) | BASIC | 4 | ||||||||||||||||
| 10 | Recycled Material Report/Construction Debris report | BASIC | 4 | ||||||||||||||||
| 11 | State Notification for Demolition & Renovation 10 Day Notice | BASIC | 4 | ||||||||||||||||
| 12 | Disinfection Report for Domestic Water | BASIC | 4 | ||||||||||||||||
| 13 | EPA Certifications of Personnel | BASIC | 4 | ||||||||||||||||
| 14 | Air Emission Source Specifications | BASIC | 4 |
Architectural
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| 15 | Architectural Drawings | BASIC | 4 | ||||||||||||||||
| 16 | Gypsum board | BASIC | 4 | ||||||||||||||||
| 17 | Acoustical Ceiling System | BASIC | 4 | 4 | |||||||||||||||
| 18 | Primer/Paint | BASIC | 4 | 4 | 4 | ||||||||||||||
| 19 | Sealant/Caulk | BASIC | 4 | ||||||||||||||||
| 20 | Door(s) | BASIC | 4 | ||||||||||||||||
| 21 | Door hardware | BASIC | 4 | ||||||||||||||||
| 22 | Door frame(s) | BASIC | 4 | ||||||||||||||||
| 23 | Windows | BASIC | 4 | ||||||||||||||||
| 24 | Cabinets | BASIC | 4 | 4 | 4 | ||||||||||||||
| 25 | Countertops | BASIC | 4 | 4 | 4 | ||||||||||||||
| 26 | Flooring (tile, carpet, etc…) | BASIC | 4 | 4 | 4 | ||||||||||||||
| 27 | Wall tile | BASIC | 4 | 4 | 4 | ||||||||||||||
| 28 | Cove Base (tile, vinyl, wood, etc…) | BASIC | 4 | 4 | 4 | ||||||||||||||
| 29 | Paper Towel Dispenser | BASIC | 4 | ||||||||||||||||
| 30 | Waste Recepticle | BASIC | 4 | ||||||||||||||||
| 31 | Soap Dispenser | BASIC | 4 | ||||||||||||||||
| 32 | Toilet Paper Dispenser | BASIC | 4 | ||||||||||||||||
| 33 | Mirror | BASIC | 4 | ||||||||||||||||
| 34 | Plumbing Fixture(s) | BASIC | 4 | ||||||||||||||||
| 35 | Grab Bars | BASIC | 4 | ||||||||||||||||
| 36 | Equipment Manuals | BASIC | 4 | ||||||||||||||||
| 37 | Test Reports | BASIC | 4 |
Civil
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| 38 | Site/Civil Plan and Calculations | BASIC | 4 | ||||||||||||||||
| 39 | Test Reports | BASIC | 4 | ||||||||||||||||
| 40 | Equipment Manuals | BASIC | 4 |
Mechanical
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| 41 | Mechanical Plan and calculations | BASIC | 4 | ||||||||||||||||
| 42 | Test Reports | BASIC | 4 | ||||||||||||||||
| 43 | Air Handling Units | BASIC | 4 | 4 | 4 | 4 | 4 | ||||||||||||
| 44 | Fan Coil Units | 4 | 4 | 4 | 4 | 4 | |||||||||||||
| 45 | Heating and Cooling Piping | BASIC | 4 | ||||||||||||||||
| 46 | Ducting and Ducting Design | BASIC | 4 | 4 | |||||||||||||||
| 47 | Diffusers/Registers/Grilles/Louvers | BASIC | 4 | 4 | |||||||||||||||
| 48 | Direct Digital Controls | BASIC | 4 | 4 | 4 | 4 | 4 | ||||||||||||
| 49 | Testing/Adjusting/Balancing Reports | BASIC | 4 | ||||||||||||||||
| 50 | Domestic Water Piping, Fittings and Hardware | BASIC | 4 | ||||||||||||||||
| 51 | Water Heater | BASIC | 4 | 4 | 4 | 4 | 4 | ||||||||||||
| 52 | Lavatories | BASIC | 4 | ||||||||||||||||
| 53 | Water Closets | BASIC | 4 | ||||||||||||||||
| 54 | Flush Valves | BASIC | 4 | ||||||||||||||||
| 55 | Urinals | BASIC | 4 | ||||||||||||||||
| 56 | Exhaust Fan | BASIC | 4 | 4 | |||||||||||||||
| 57 | Hangars and Supports | BASIC | 4 | 4 | |||||||||||||||
| 58 | Flashing | BASIC | 4 | ||||||||||||||||
| 59 | Sleeves | BASIC | 4 | ||||||||||||||||
| 60 | Mechanical Identification/Nameplates/Markers | BASIC | 4 | ||||||||||||||||
| 61 | Duct/Piping Insulation | BASIC | 4 | ||||||||||||||||
| 62 | Pumps/Pump Curves | BASIC | 4 | 4 | 4 | 4 | 4 | ||||||||||||
| 63 | Valves | BASIC | 4 | 4 | 4 | 4 | 4 | ||||||||||||
| 64 | Equipment Manuals | BASIC | 4 | ||||||||||||||||
| 65 | Test Reports | BASIC | 4 | ||||||||||||||||
| 66 | Firestopping and Accessories | BASIC | 4 |
Electrical
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| 67 | Electrical Plan and Calculations | BASIC | 4 | ||||||||||||||||
| 68 | Circuit Breakers | BASIC | 4 | 4 | 4 | ||||||||||||||
| 69 | Ground Rods and Connectors | BASIC | 4 | ||||||||||||||||
| 70 | Electrical Hangars and Supports | BASIC | 4 | 4 | 4 | ||||||||||||||
| 71 | Electrical Identification/Nameplates/Markers | BASIC | 4 | ||||||||||||||||
| 72 | Building Wire | BASIC | 4 | ||||||||||||||||
| 73 | Raceway and Boxes | BASIC | 4 | ||||||||||||||||
| 74 | Receptacles/Switches | BASIC | 4 | ||||||||||||||||
| 75 | Motors | BASIC | 4 | 4 | 4 | 4 | |||||||||||||
| 76 | Fuses | BASIC | 4 | 4 | 4 | ||||||||||||||
| 77 | Disconnect Switches | BASIC | 4 | 4 | 4 | ||||||||||||||
| 78 | Dry-Type Transformers | BASIC | 4 | 4 | 4 | 4 | |||||||||||||
| 79 | Luminaires | BASIC | 4 | 4 | 4 | ||||||||||||||
| 80 | Emergency Lighting | BASIC | 4 | 4 | 4 | ||||||||||||||
| 81 | Communications Wire | BASIC | 4 | ||||||||||||||||
| 82 | Communications Circuits Test/Certification Reports | BASIC | 4 | ||||||||||||||||
| 83 | Test Reports | BASIC | 4 | ||||||||||||||||
| 84 | Equipment Manuals | BASIC | 4 |
Special Systems
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| NA |
Other & Misc
| SCHEDULE OF MATERIAL SUBMITTALS | Project No: | Project Title: | Date: | ||||||||||||||||
| FA302218R0007 | Repair UEQ HVAC/Interior Finishes B550 | 8-Nov-17 | |||||||||||||||||
| LINE NO. | ITEM DESCRIPTION | SPEC REF | NUMBER OF COPIES REQUIRED | DATE KTR REQUIRES APPROVAL | DATE RECEIVED KTR | DATE TO CIVIL ENG | DATE RECEIVED FROM CE | DATE CONTRACTOR NOTIFIED APR DISAPR | CONTRACT RESUBMIT DUE | CONTRACT RESUBMITTAL RECEIVED | FINAL APPROVAL RCVD KTR NOTIFIED | ||||||||
| Certificate of Compliance | Shop Drawings | Samples | Color Selction | Manufacturer's Recommendations | Manufacturer's Warranty | Catalog Data | Operating Instructions | Other | |||||||||||
| GENERAL | |||||||||||||||||||
| NA |
File details come from the government source that posted it.