This document outlines requirements for a federal contract opportunity to upgrade door locks at a dormitory building at Joint Base San Antonio - Fort Sam Houston. The contractor shall provide all management, labor, tools, equipment and supplies necessary to deliver and install replacement locking mechanisms including electronic strikes, card readers, and key card access systems. Responses are due by September 3, 2020 and should be submitted to Contract Specialist Melissa De Coste. The installation will upgrade locks at Building 1479 to improve security for dorm rooms through use of card reader and electric strike components that meet specifications for tamper resistance, voltage tolerance, and force ratings provided in an attachment specifying salient characteristics.
View the file
Other files for this federal contract opportunity
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Card Reader Requirements
Brand Name or Equal: HID Mini R10
Salient Characteristics:
− Card Compatibility: Secure Identity object, PIV cards and FOB − ANSI/BHMA A156.5 and ANSI/BHMA A156.25 Grade 1 − Tamper and vandal resistant − Display light to indicate access − Rated for continuous duty − Standalone device − Must integrate/function with electric door strike − Capable of being hardwired to a power supply − Voltage max: 24VDC
Electric Strike Requirements
Brand Name or Equal: HES 1006
Salient Characteristics:
− Must be able to be hardwired to a power supply.
− Stainless steel construction − ANSI/BHMA A156.31 Grade 1 compliance − Rated for continuous duty − Strike must have multiple faceplate options so that it may fit on current door frame and door latches to minimize additional modifications.
− Plug-in connector − Internally mounted solenoid − Tamper resistance UIL 1034 − Full keeper shims to allow for horizontal adjustment − Max. voltage: 24VDC − Applications: Steel/Aluminum frames − Minimum Static Strength 2500 lbs (fail secure) − Minimum Dynamic Strength 350 lbs (fail secure) − Required to recapture deadbolt