2 Sep 2020 - Salient Characteristics.pdf

PDF 229 KB Posted

Attached to
FSH Dorm Lock Upgrade Federal contract opportunity
Solicitation number
FA301620R0082
Issued by
Department of the Air Force Air Education and Training Command

About this file

This solicitation requests proposals for a dorm lock upgrade project at Joint Base San Antonio - Fort Sam Houston. The contractor shall provide all management, labor, tools, equipment, and supplies necessary to deliver and install replacement locking mechanisms including electronic strikes and card readers with key card access for dorm rooms in Building 1479. Proposals are due by September 3, 2020 and shall be submitted via email to Melissa De Coste at the listed address. The contractor must use the specified HID Mini R10 card readers and HES 1006 electric strikes, or approved equals, which must meet the salient characteristics provided in the supporting attachments such as compatibility with PIV cards, ANSI/BHMA grade 1 construction, tamper resistance, continuous duty rating, and maximum voltage of 24VDC.

View the file

Other files for this federal contract opportunity

Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Card Reader Requirements

Brand Name or Equal: HID Mini R10

Salient Characteristics:

− Card Compatibility: Secure Identity object, PIV cards and FOB − ANSI/BHMA A156.5 and ANSI/BHMA A156.25 Grade 1 − Tamper and vandal resistant − Display light to indicate access − Rated for continuous duty − Standalone device − Must integrate/function with electric door strike − Capable of being hardwired to a power supply − Voltage max: 24VDC

Please Note: Conduit is the required Installation method.

Electric Strike Requirements

Brand Name or Equal: HES 1006

Salient Characteristics:

− Must be able to be hardwired to a power supply.

− Stainless steel construction − ANSI/BHMA A156.31 Grade 1 compliance − Rated for continuous duty − Strike must have multiple faceplate options so that it may fit on current door frame and door latches to minimize additional modifications.

− Plug-in connector − Internally mounted solenoid − Tamper resistance UIL 1034 − Full keeper shims to allow for horizontal adjustment − Max. voltage: 24VDC − Applications: Steel/Aluminum frames − Minimum Static Strength 2500 lbs (fail secure) − Minimum Dynamic Strength 350 lbs (fail secure) − Required to recapture deadbolt

File details come from the government source that posted it. Updated .