3rd_Floor_Bldg_Drawing.pdf
PDF 5 MB Posted
- Attached to
- Access Control System Federal contract opportunity
- Solicitation number
- FA3016-18-U-0165
About this file
This is the 3rd floor drawing for one of the buildings. The 2nd, 3rd, and 4th floors on each of the 3 buildings are the same.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1st_Floor_Bldg_Drawing.pdf | ||
| Access_Control_System_Questions_and_Answers_25_June_2018.docx | DOCX document | |
| RFQ_Access_Control_Systems_Revised_25June2018.pdf | ||
| STATEMENT_OF_WORK_PHASE_2_Revised.pdf | ||
| Site_Visit_Questions_and_Answers_19_June_2018.pdf | ||
| RFQ_Access_Control_Systems_Revised_20June18.pdf | ||
| STATEMENT_OF_WORK_PHASE_2.docx | DOCX document | |
| RFQ_Access_Control_Systems.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N C
C , C li la b~
'" '" w w
E al ·2~ ~-cE-;::::-
El .;_;
~s w-C:
6 1l ~ ·e g_3, D
C
B
A
"' I a, N
"' I
I l!:l j I
"' N
I
DO
N
"' I
"' I a, N
"' I a, N
A-130 AA134
A-130 AA133
A-130 AA132
I I I I
I I I r I I I I I
: I l
'I I I I I I I I I
29'-3"
UNDRY
29'-3" '-6" 28'-4 1/2"
M C
------------~ ---,------r
29'-3" 29'-3' '-6" 28'-4 1/2"
2 5
27'-7" 27'-7" 27'-7"
9.3
37'-o" l A-130 A-315
........ l~ra.&i!:
A-130 A-3011 I I I I
1113EII I
9 -
M
33'-11"
GAME
ROOM
-----r------i---- --r--,........, A-130 A-317
A-130 A-317
27'-7' 27'-7" 27'-7" 28'-10 1/4" 33'-11'
10.7 r
33'-11"
BRIEFING
ROOM
- 11
I I I I
37'-o"
A-130 A-301
27'-7"
27'-7'' 27'-t" 28'-4 1/2"
SIMILAR, O.H.
29'-3"
29'-3"
MECHANICAL
ROOM
----1------1------1---~--1------1--------1-------
A-130 -312
33'-11' 28'-10 1/4" 27'-7" 27'-7" 27'-7' 28'-4 1/2" '-6" 29'-3" 29' -3'
11 12 14 19 l I I
I
A-130 AA134
13J-
-----'«-----< A
------'k---< B
"' I a, N
"' I
• N
I
DO
N
• r-- I
"' N j I
"' N
E
F
TYPICAL
----~'k----j H
I
DO
N
"' I
"' I gJ
"' I gJ
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED,
IN PART, ON THE BASIS OF INFORMATION COMPILED
BY OTHERS. THEY ARE NOT INTENDED TO
REPRESENT IN DETAIL THE EXACT LOCATION, TYPE
OF COMPONENT NOR MANNER OF CONSTRUCTION.
BASED ON THE INFORMATION AVAILABLE TO
JACOBS THE PROVIDED DATA APPEARS TO
REPRESENT TI-lE PROJECT AS CONSTRUCTED.
OVERALL
KEY PLAN
TRUE
NORTH
PLAN
NORTH
US Army Corps of Engineers Fort Worth District
ID
. 0 Oo
ZI
"' c I 0~
O> :;::; 0 o o I '- ~ <.> .. 0 •- (0
2 N .~ N 0 ";;:, 0 gj 0 o U1 ::i=:
.D u z c'j "3 0 .. "'
.D I" uW ID o_ >, C :,e .D
ID :::J C
• oj ID ~ 0 §S Oo
"' 0 t=
"' zo 0 C, Ui ',,' =, w Oo :r: =, e- :::, U1
1Ji t;l t,:: :::, S: :r:
1c'
5,1
' ~ 8
• I
Oo z ,I, ~ 0 u I 0 <.> b~ c_
8~
>. Cl
.D "' u :'i
ID~ ·~ ID W
> "' ID =,
:z :::5 (1..
_J _J
"" w
"" 0 g
LL.
C, .D u c1! .E .D , VI
Sheet reference number:
A-130
:I: ,.
u
C, N
"' I
"' z is C u i ili
Sheet 12 of 240 c
.ii
C i ·c j
-l' 0 ,.
c~ bW
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
1058726717C Highlight
D
C ii:
B
A ll
9000 SYSlE~ LOCK POWER
CONTROLLER SUPPLY
READER
EXPANSION
I 48 DOOR POSITION 5
49 DOOR POSITION 6
50 DOOR POSITION 7
51 DOOR POSITION 8 -
43 DOOR POSITION 1
~ 44 DOOR POSITION 2
~ 46 DOOR POSITION 3 -
47DOOR POSITION 4
9000 SYSlE~ LOCK POWE~
CONTROLLER SUPPLY
READER
EXPANSION
I -36 DOOR POSITION 5
Tl DOOR POSITION 6
'.38 DOOR POSITION 7
fg DOOR POSITION 8 fil]DOOR POSITION 1 - Lfil]DOOR POSITION 2
-- 34 DOOR POSITION 3
= 35 DOOR POSITION 4 -
ll
9000 SYSlE~ LOCK POWER
CONTROLLER SUPPLY
READER
EXPANSION
I 24DOOR POSITION 5
25 DOOR POSITION 6 -26 DOOR POSITION 7
27 DOOR POSITION 8
@DOOR POSITION 1 -
20 DOOR POSITION 2
22 DOOR POSITION 3
23 DOOR POSITION 4
ll_ ll
9000 SYSTEM LOCK POWER
CONTROLLER SUPPLY
READER
EXPANSION
I 12 DOOR POSITION 5
13 DOOR POSITION 6 - DOOR POSITION 7
_ DOOR POSITION 8
9 IDOOR POSITION 1
1 QA IDOOR POSITION 2
L_jj OB IDOOR POSITION 3
:11 IDOOR POSITION 4
Ir I COAX CABLE (TYPICAL)
-AMP
F
(.I) c::: w
0 -
TPZ
TPZ
TPZ
TPZ
TPZ
TPZ
AMP
AMP
AMP
AMP
AMP
VIDEO
DISTRIBUTION AMPLIFIER
VIDEO
DISTRIBUTION AMPLIFIER
VIDEO
DISTRIBUTION AMPLIFIER
VIDEO
DISTRIBUTION AMPLIFIER
2 3
~ l§_
9000 SYSTEM LOCK POWER
ELECTRIC ROOM 4161 CONTROLLER SUPPLY
READER
EXPANSION ELECTRIC ROOM 4261
-45 DOOR POSITION 1
- 32 DOOR POSITION 2
- ~ DOOR POSITION 3 -
FOURTH FLOOR 54 DOOR POSITION 4
9000 SYSTE~ LOCK POWElf
ELECTRIC ROOM 3161 CONTROLLER SUPPLY
READER
EXPANSION ELECTRIC ROOM 3261
filDOOR POSITION 1
L..J1QIDOOR POSITION 2 -- 41 DOOR POSITION 3
THIRD FLOOR 42 DOOR POSITION 4 -
9000 SYSTE~
Li
LOCK POWER
ELECTRIC ROOM 2161 CONTROLLER SUPPLY
READER
EXPANSION ELECTRIC ROOM 2261
@DOOR POSITION 1
28 DOOR POSITION 2
29 DOOR POSITION 3
SECOND FLOOR
30 DOOR POSITION 4
' l1_ ll l1_
9000 SYSTEM 9000 SYSTEM LOCK POWER
CONTROLLER ELECTRIC ROOM 1161 CONTROLLER SUPPLY
READER READER
EXPANSION EXPANSION ELECTRIC ROOM 1261
I 5 DOOR POSITION 5 I 17 DOOR POSITION 5
6 DOOR POSITION 6 CENTRAL 18 DOOR POSITION 6
CONTROL
7 DOOR POSITION 7 DOOR POSITION 7
= PANEL =
-{IJDOOR POSITION 1
_§_ DOOR POSITION 8
-DI]DOOR POSITION 1
_ DOOR POSITION 8
SECURITY ROOM 1347A
2 DOOR POSITION 2 15A DOOR POSITION 2
------Q]DOOR POSITION 3
FIRST FLOOR
------O][]DOOR POSITION 3
4 DOOR POSITION 4 16 DOOR POSITION 4
f 1 \ ACCESS CONTROL SYSTEM RISER DIAGRAM E ~ 70fil-i05 SCALE: NTS
MATRIX SWITCH
COAX CABLE
(TYPICAL)
RACK MOUNT
SERVER
CCTV CCTV CCTV
CQ OPERATOR
STATION
---~WORKROOM 6 OPERATOR
STATION
DD
CCTV CCTV CCTV
NETLINK
~,,__----+--~24 PORT ETHERNET
SWITCH
CAT 5E CABLE (TYPICAL
2 VIDEO SURVEILLANCE SYSTEM
E-705 E-705 SCALE: NTS
GENERAL SHEET NOTES
A. ALL WIRES AT FCP TO BE INDENTIFIED AND TAGGED
FOR PROPER TERMINATION.
B. ALL WIRING TO BE A MINIMUM OF 18 AWG.
C. ALL WIRES TO TEST FREE OF SHORTS AND GROUNDS.
D. WIRING OF THE MAGNETIC LOCK TO THE EGRESS
DEVICE SHALL CONSIST OF BREAKING LOCK POWER AS
WELL AS REQUESTING EXIT FROM ACCESS CONTROL
EQUIPMENT.
E. BATIERY BACKUP TO BE PROVIDED TO ACCOMMODATE
4 HOURS OF OPERATION WITHOUT PRIMARY POWER.
F. INSTALLATION TO BE PER NEC ARTICLE 760, NFPA 72
AND OTHER REQUIRED STANDARDS.
G. CARD READERS AND EGRESS BUTIONS TO BE
MOUNTED AT +48" AFF.
H. CARD READER WIRING TO BE STRANDED SHIELDED 8
CONDUCTOR. SHIELD TO BE CONNECTED TO PANEL
GROUND.
1K OHM
EGRESS DEVICE 5
IMPUT POINT SECTION
1K OHM
EGRESS DEVICE 6
DOOR STATUS 1
MAIN ENTRY
DOOR STATUS 2
1K OHM
EGRESS DEVICE 7
1K OHM
EGRESS DEVICE 8
DOOR
POSITIONS
IMPUTS
BREAK RM ENTRY~~~---,
DOOR STATUS 3
CONTROL RM ENT.~~~---,
DOOR STATUS 4 ~~/
WAREHOUSE ENT. ~~~----,
DOOR STATUS 5
SPARE ~1K'-'O=H=M----1
DOOR STATUS 6
SPARE ~1K~O~H~M-~_,
DOOR STATUS 7
SPARE
DOOR STATUS 8
SPARE
IREMOTEl/0-[
@MMUNICATIONS
TAMPER SWITCHC
TYPICAL WIRING FOR ALL CARD READERS
1 23456789
READER 1
WHITE DATA 1
GREEN DATA 0
NOT USED
RED +9.6V
BLACK GROUND
NOT USED
NOT USED
ORANGE PROCEED LED
BLUE KEYPAD DATA
READER 2
1K OHM
1K OHM
EGRESS DEVICE 3
1K OHM
EGRESS DEVICE 2
1K OHM
EGRESS DEVICE 1
9000 CONTROL PANEL
---, MAIN POWER
__J 12 voe 2ovA
POWER SUPPLY
SECTION
---, BATTERY
__J 12 voe 32H
RELAY SECTION
~c -----;IS;;:;E;:;;E:::;E;;::;x:;-.l ---11i<1K1r=-TiLo"irc'i<K11---i
NO- . BELOW.
~c ----;:;IS;';;EE~Ex~.
-----11ii<'K2~-TiLo'Yc'i<K ?2'1j
NO- . BELOW.
Ncc----;:;1s;;;EE~EX~.l-----jjli7K3'i:-TiLOYC'i<K13:lj
NO- . BELOW.
~c --;:;I S;;;;EE~Ex~.
-----111i1.K 4.r.:-TiLo'Yc'i<K °A4:lj
NO- . BELOW.
NCC ==--:=.,-;:;IS;;;;EE~EX~.l-----jjik'iK5:;::_:fiLOYC'i<K<;5:lj
NO- . BELOW.
NCC ISEE EX.I
NO- . BELOW.
~c ==ic1s~EE~Ex§:.I ~j[KK7'0_-]Loic~KJ7=:Jj
NO- . BELOW.
jK6-LOCK 6 j
~c
NO- SUPRESSOR LK
KIT E
EGRESS
DEVICE
CONTACT 1
DC POWER 1---------1.-<TT"?)..J
READER 3
TYPICAL DOOR
9000 CONTROL PANEL
SUPPLY
TYPICAL DRWG. OF MAGNETIC DOOR LOCK WIRING
READER 4
TYPICAL DOOR
(CARD READER EXPANSION BOARD WHERE INDICATED)
!WHITE I DATA 1
. GREEN DATA 0
I I NOT USED
· RED +9.6V
I BLACK I GROUND
I I NOT USED
I I NOT USED
I ORANGE 1 PROCEED LED
I BLUE I KEYPAD DATA IL_ _ _J
1 23456789
READER 5 READER 6
TYPICA' nnnR I I 'Al 111 J[Jt(
READER 7
TYPICAL DOOR
I
READER 8
TYPICAL DOOR
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED,
IN PART, ON THE BASIS OF INFORMATION COMPILED
BY OTHERS. THEY ARE NOT INTENDED TO
REPRESENT IN DETAIL THE EXACT LOCATION, TYPE
OF COMPONENT NOR MANNER OF CONSTRUCTION
BASED ON THE INFORMATION AVAILABLE TO
JACOBS THE PROVIDED DATA APPEARS TO
REPRESENT TI-IE PROJECT AS CONSTRUCTED.
US Army Corps of Engineers Fort Worth District
Sheet reference number:
E-705 u
0, N al I
"' z is C
Sheet 221 of 240
" ~ ,I-
C
I 'C
M
-l' c~ bW