Attachment_12__Schedule_B-_Cost_Estimation_Breakdown.xlsx

XLSX spreadsheet 16 KB Posted

Attached to
Replace Mechanical Components HVAC B 5010 Federal contract opportunity
Solicitation number
FA3016-17-R-0033
Issued by
Department of the Air Force Air Education and Training Command

About this file

Attachment 12 - Schedule B - Cost Estimate Breakdown (1 page)

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1

CONSTRUCTION COST ESTIMATE BREAKDOWN
CONTRACTOR
ADDRESS
General Construction Subtotal
General Construction Labor Burden
RSMeans San Antonio, TX CCI
General Construction Prime Contractor Overhead
General Construction Prime Contractor Profit
General Construction Prime Contractor Bonding
General Construction Contingency
CONTRACT FOR (Work to be performed)This cost proposal is valid for daysProposed Project Amount
RPR-Mechanical�Components B-5010The period of performance to perform this work is days.
PURCHASE REQUEST NUMBERPROJECT NUMBER
CYRB110224WORK LOCATIOND
LINE NO.ITEM DESCRIPTIONUNIT OF MEASURE
QUANTITYMATERIAL COSTSLABOR COSTSEQUIPMENT COSTSOTHER COSTSLINE TOTAL
UNITTOTALCREWLABOR HOURSAVERAGE RATETOTALUNITTOTALUNITTOTAL
101-11-31-20-0070 Construction management fees, for work to $250,000Project
201-31-13-20-0160 Field personnel, general purpose laborer, averageWeek
301-31-13-20-0200 Field personnel, project manager, averageWeek
401-31-13-20-0260 Field personnel, superintendent, averageWeek
522-11-13-23-1120 Pipe/tube, copper, solder joints, type K tubing, couplings and clevis hanger assemblies, 10' O.C., 3/8" diameterL.F.
622-11-13-23-1160 Pipe/tube, copper, solder joints, type K tubing, couplings and clevis hanger assemblies, 10' O.C., 5/8" diameterL.F.
723-05-05-10-0100 HVAC demolition, air conditioner, split unit, 3 tonEa.
823-09-53-10-5200 Control components, thermostats, 24 hour, automatic, clockEa.
923-23-23-20-4440 Refrigerant, refrigerant, R-408A, 25 lbs. disposable cylinderLb.
1023-81-23-10-1120 Computer room units, air cooled, includes remote condenser, excluding interconnecting tubing or refrigerant, 5 tonEa.
1126-28-16-20-4340 Safety switches, heavy duty, 240 volt, 2 pole, NEMA 1, fusible, 30 ampEa.

Attachment 12_ Schedule B- Cost Estimation Breakdown

File details come from the government source that posted it. Updated .