This package includes construction drawings and specifications for the relocation of equipment and personnel offices from Facility 1704 to Facility 85 125, Rooms 203, 204, and 205 at Cape Canaveral Air Force Station in Florida. The scope of work involves architectural, interiors, mechanical, fire protection and electrical construction services to outfit the new spaces. Drawings cover demolition plans, floor plans, reflected ceiling plans, equipment layouts, building sections, elevations, and construction details. Mechanical drawings include general notes, abbreviations, legends, demolition plans, floor plans, raised floor plans, details and schedules. Electrical drawings cover general notes, symbols, demolition plans, equipment power plans, receptacle plans, lighting plans, details, single line diagrams and panel schedules. Fire alarm and communications drawings provide general notes, demolition plans, floor plans, riser diagrams and outlet plans.

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FLOOR PLAN LEGEND

WALLS

DOOR

REFER TO DOOR SCHEDULE

PARTITION TYPE INDICATOR

REFER TO PARTITION TYPES ON THIS SHEET

WINDOW TAG

REFER TO WINDOW TYPES

KEYNOTE

xx

NOTE: ALL ITEMS SHOWN IN THIS LEGEND MAY NOT APPLY TO THIS SHEET

B C D E

8'-11" 28'-11"

STAIR

OFFICE

205B

OFFICE

205C

OFFICE

205A

STARS USERS

ROOM

DATA REDUCTION

CONTROL

CENTER

204A

DATA REDUCTION

CENTER

205A

B

C

204A 204B

A-501

A2

FACILITY

ELECTRICAL

E

15 01

A-202

B5

A-202

B3

A-202

17'-10 5/8"

C2

E Q

E Q

E Q

E Q

E Q

E Q

E Q

OFFICE

C

A

B

7'-8"

A-202 A5B1 A-202

A1

A-202

A3

A-501

A2 Sim

A-501

A2 Sim

" 4

1'-6"

ALIGN

07 C1

D1

A-201

B1

A-201

A3

A-201

A1

A-201

C4

C3

A-202

B2

10'-0"

9'-4"

TYPE 2 FULL HEIGHT NON-RATED INTERIOR PARTITION

TYPE 3 NON-RATED INTERIOR PARTITION, GWB

TERMINATES AT 8" ABOVE CEILING TILE

PARTITION TYPES

5/8" GWB BOTH SIDES ON 3 5/8" MTL STUD

FRAMING AT 16" OC

5/8" GYP SOUND BOARD BOTH SIDES ON 6"

MTL STUD FRAMING AT 16" OC.

STC 45 [B.O.D. NGC 2013023]

SOUND ATTENUATION

SOUND ATTENUATION

TYPE 1 FULL HEIGHT NON-RATED INTERIOR PARTITION

5/8" GYP SOUND BOARD BOTH SIDES ON 3

5/8" MTL STUD FRAMING AT 16" OC

STC 45 [B.O.D. NGC 2013005]

SOUND ATTENUATION

TYPE 4 NON-RATED CHASE PARTITION, GWB

TERMINATES AT 8" ABOVE CEILING TILE

5/8" GYP SOUND BOARD ON ONE SIDE OVER

2 1/2" MTL STUD FRAMING

"8

TYPE 3 TYPE 2TYPE 4

STC 45

5/8" GWB ON MTL STUD

FRAMING AT 16" OC.

BASE AS SCHEDULED

CEILING AS

SCHEDULED

BASE AS SCHEDULED

CEILING AS

SCHEDULED

SOUND ATTENUATION

ACOUSTIC SEALANT

ACOUSTIC SEALANT

BASE AS SCHEDULED

CEILING AS

SCHEDULED

5/8" GWB BOTH SIDES

ON MTL STUD FRAMING

AT 16" OC

UNDERSIDE OF DECK UNDERSIDE OF DECK

UNDERSIDE OF

DECK

EXISTING RATED

PARTITION

EXISTING RAISED

FLOOR PANEL

UTILITY GROMET

EXISTING FLOOR

SLAB

MTL STUD KICKER

@ 8'-0" O.C. MAX

MTL STUD KICKER

@ 8'-0" O.C. MAX

EXISTING RAISED

FLOOR PANEL

EXISTING FLOOR

SLAB

MECH.

DUCTWORK

5/8" GYP SOUNDBOARD

BOTH SIDES ON MTL

STUD FRAMING AT 16"

OC

EXISTING RAISED

FLOOR PANEL

EXISTING FLOOR

SLAB

SOUND ATTENUATION

DEFLECTION TRACK

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

SHEET OF

T H

S P

A C

E W

IN

G

C C

A F

S F

L

C O

N T

R A

C T

N O

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

D E

L

IV

E R

Y O

R D

E R

N O

C

K D

B Y x

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

T R

A C

E S

T E

C H

N

IC

A L R

A N

G E

A R

C H

IT

E

C T

U R

A L E

N G

IN

E

E R

IN

G

S E

R V

IC

E

S

A A rh o d e s b ri to

A

C

H

I T

E

S s i n d ic a te d

/2

/2

:5

:2

P

M

E R

S T

A R

S R

E L

O C

A T

IO

N

A-101

F L O

O R

P L A

N

D B

E H

-1

A A

-1

F A

-1

D

-0

A u g u s t

F A

F A

F A

-1 D

-0

D e s ig n e r

A u th o r

A p p ro v e r

C h e c k e r

GENERAL NOTES - PLAN

A THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND SHALL

VERIFY THESE DRAWINGS WITH THE EXISTING FIELD

CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE

CONTRACTING OFFICER OF ANY ISSUES.

B CONFORM TO ALL APPLICABLE CODES FOR DEMOLITION AND

NEW WORK. FOR ADDITIONAL GENERAL NOTES, LEGENDS,

AND SCHEDULES REFER TO SHEET G002.

C CONTRACTOR TO PROVIDE ENGINEERED SHOP DRAWINGS

AND FL PRODUCT APPROVALS FOR REVIEW BY THE DESIGN

TEAM PRIOR TO FABRICATION OF ALL ASSEMBLIES.

D COORDINATE ALL SHUT-DOWNS IN UTILITY SERVICE WITH THE

CONTRACTING OFFICER PRIOR TO PERFORMING SHUT-DOWNS

IN UTILITY SERVICE.

E MAINTAIN THE CONTINUITY OF CONSTRUCTION OF ALL

FIRE-RATED ASSEMBLIES (I.E. DOORS, GYPSUM ENCLOSURES,

SPRAYED FIRE PROOFING, ETC.) AT ALL EXISTING AND NEW

LOCATIONS INCLUDING BUT NOT LIMITED TO STRUCTURAL

COLUMNS, BEAMS, AND FLOOR SLABS.

F ALL CONDUIT PIPING IN ELECTRICAL ROOMS TO BE

CONCEALED WITHIN THE WALL CONSTRUCTION.

G WHERE ELECTRICAL, MECHANICAL AND/OR PLUMBING ITEMS,

SUCH AS LIGHTS, DUCTS, PIPING, DOWNSPOUTS, ETC. ARE

SHOWN TO PENETRATE OR CONFLICT WITH ANY BUILDING

FOOTINGS, SLABS, FLOORS, STRUCTURAL FRAMING, WALL

PARTITIONS, CEILINGS, ETC., IT IS REQUIRED THAT AN

APPROPRIATELY SIZED OPENING OR CLEARANCE BE

FURNISHED. THE CONTRACTOR SHALL COORDINATE THE

INSTALLATION OF ALL ITEMS WITH THE CONSTRUCTION

DOCUMENTS PRIOR TO THE INSTALLATION OF STRUCTURAL,

MECHANICAL, PLUMBING AND ELECTRICAL WORK. ANY

CONFLICT OR DISCREPANCY WITHIN THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE CONTRACTING

OFFICER'S ATTENTION FOR CLARIFICATION. ANY WORK

INSTALLED IN CONFLICT WITH THE ARCHITECTURAL

DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT

NO EXPENSE TO THE CONTRACTING OFFICER.

H CONTRACTOR SHALL COORDINATE WITH CONTRACTING

OFFICER CONCERNING THE PROPER REMOVAL OF ALL DEBRIS

ASSOCIATED WITH THE WORK.

I THE GENERAL CONTRACTOR SHALL MAINTAIN A CLEAN AND

ORDERLY JOBSITE, FREE OF DEBRIS AND LITTER. UPON

COMPLETION, ALL CONTRACTORS SHALL REMOVE THEIR

TRASH AND DEBRIS FROM THE PREMISES. ALL AREAS SHALL

BE BROOM CLEANED.

J ALL DIMENSIONS ARE TO FACE OF CURB, FACE OF CONCRETE

OR MASONRY, FACE OF FINISH, OR CENTERLINE OF GRID

UNLESS NOTED OTHERWISE.

K CONTRACTOR SHALL FIELD MEASURE AS REQUIRED FOR ALL

WORK RELATED TO GLAZING AND MILLWORK PRIOR TO

FABRICATION.

L CONTRACTOR SHALL ENSURE THAT ALL ENTRANCES AND

EXITS FROM THIS TENANT IMPROVEMENT SPACE MEETS

ACCESSIBLE MEANS OF EGRESS REQUIREMENTS

M CONTRACTOR SHALL COORDINATE WALL INSTALLATION WITH

EXISTING FIRE SUPPRESSION SPRINKLER HEAD LOCATION.

CONTRACTOR SHALL MAINTAIN 4" MIN. CLEARANCE FROM

CENTER OF SPRINKLER HEAD TO FACE OF WALL.

04 8 16268

SCALE: 1/8"=1'-0"

1/4" = 1'-0"A-101

B1 PARTIAL SECOND FLOOR PLAN

KEYNOTE LEGEND

01 NEW EQUIPMENT, SEE EQUIPMENT PLAN

02 PATCH EXISTING WALL TO THE SAME LEVEL OF FINISH AS

ADJACENT WALL CONSTRUCTION. MAINTAIN CONTINUITY OF

FIRE RATING.

04 NEW DOOR, FRAME AND HARDWARE

05 MODIFY FRAMES FOR NEW HW, MAINTAIN PARTITION RATING

AT OPENING

06 PRINTER BY OTHERS, PROVIDE EMERGENCY POWER

07 VERIFY PARTITION IS FULL HEIGHT [ROOF DECK TO FLOOR

SLAB] & STC 45 RATING. MODIFY AS NECESSARY.

08 VIDEO DISPLAY MONITORS, OFCI

11 PATCH AND REPAIR EXISTING WALLS AND CEILINGS IN

CORRIDOR, ELECTRICAL, MECHANICAL AND COMMS ROOM

AS NECESSARY. COORDINATE WITH ENGINEERING

DRAWINGS.

13 STATIC DISSIPATIVE CARPET TILE, MATCH EXISTING, PLACE

TRANSITION BELOW DOOR IN CLOSED POSITION

15 ALIGN EQUIPMENT W/ RAISED FLOOR TILES WHERE

POSSIBLE. CONTRACTOR SHALL FIELD VERIFY FLOOR TILE

LOCATION AND FULLY COORDINATE W/ EQUIPMENT FOR

LOCATION. MINIMIZE CUTTING OF TILES. USE MFR'S DETAILS

FOR BRIDGING, TRIM, ETC AS NECESSARY TO CONFORM W/

PLAN

PLAN NORTH

jrb30077 Callout Add Metal Backing for AV Walls to match dimensions shown on AV Elevations jrb30077 Callout Add Metal Backing for AV Walls to match dimensions shown on AV Elevations

TS

B C D E

101 102 103 104 105

112113114116117

M

IN

MIN

3'-0"

/8

4'-6 1/4"

4'-5"

4'-3 7/16"4'-6 1/4"5'-6 3/16"

4'-5 1/2"

ALIGN

ALIGN

ALIGN

3'-11 11/16"

ALIGN

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

SHEET OF

T H

S P

A C

E W

IN

G

C C

A F

S F

L

C O

N T

R A

C T

N

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

D E

L

IV

E R

Y O

R D

E R

N O

C

K D

B Y x

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

T R

A C

E S

T E

C H

N

IC

A L R

A N

G E

A R

C H

IT

E

C T

U R

A L E

N G

IN

E

E R

IN

G

S E

R V

IC

E

S

A A rh o d e s b ri

/4

/2

/2

:5

:2

P

M

E R

S T

A R

S R

E L

O C

A T

IO

N

A-103

E Q

U

IP

M E

N T

P L A

N

D B

E H

-1

A I

A -1

F A

-1

D

-0

A u g u s t

F A

F A

F A

-1 D

-0

D e s ig n e r

A u th o r

A p p ro v e r

C h e c k e r

1/4" = 1'-0"A-103

C1 SECOND FLOOR EQUIPMENT PLAN

02 4 8134

SCALE: 1/4"=1'-0"

EQUIPMENT SCHEDULE

EQUIP

NO. EQUIPMENT REMARKS FURNISH INSTALL

15 10-TONS CRAC UNIT UNIT MOUNTED ON STEEL SUPPORT. CONTRACTOR CONTRACTOR

16 10-TONS CRAC UNIT UNIT MOUNTED ON STEEL SUPPORT. CONTRACTOR CONTRACTOR

17 SINGLE STATIC UNINTERRUPTED POWER SUPPLY UNIT BATTERY PACK COMPONENT MOUNTED ON STEEL SUPPORT. CONTRACTOR CONTRACTOR

20 STARS USER ROOM CONSOLE-1 OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.

CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.

VENDOR VENDOR

21 STARS USER ROOM CONSOLE-2 OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.

CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.

VENDOR VENDOR

22 DRC CONTROL ROOM CONSOLE OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.

CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.

VENDOR VENDOR

23 DISPLAY VIDEO WALL OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.

CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.

VENDOR VENDOR

101 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

102 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

103 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

104 MOVABLE RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

105 MOVABLE RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

106 EIS RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

107 EIS RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

108 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

109 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

110 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

111 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

112 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

113 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

114 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

116 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

117 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR

PLAN NORTH

jrb30077 Callout See AV Elevations for additional layout information

MIN 16 GA, 6" MTL STUD,

SPACE 16" OC

FASTENER

MIN 16 GA, 6"

UNPUNCHED MTL STUD,

EXTEND FULL LENGTH

OF SIGN OR

ARCHITECTURAL

ELEMENT. PLACE STUD

AT EA END.

COORDINATE LOCATION

OF BACKING W/

EQUIPMENT PLAN

SHADE HOUSING

ROLLER TUBE SHADE

ASSEMBLY ( MANUAL)

ROLLER SHADE SYSTEM

EXISTING WALL

SILL BEYOND

EXISTING

STOREFRONT

ACOUSTIC JOINT

FILLER

DOUBLE MTL STUD

AT END OF PARTITION

ANODIZED ALUM

END CAP, MATCH

STOREFRONT

SOUND ATTENUATING

WALL CLOSURE [B.O.D.

MULL IT OVER]

SUSPENDED ACOUSTICAL

CEILING

SUSPENSION CEILING WALL

ANGLE

WALL AS SCHEDULED

PATCH AND REPAIR EXISTING

RAISED FLOOR SYSTEM AS

NECESSARY, PROVIDE NEW

FLOOR COVERING

STRUCTURAL FLOOR

MONITOR BACKING WHERE

REQUIRED

FASTEN CONT CHANNEL

TO CONC FLOOR OVER

(2) CONT BEADS OF

SEALANT

ACOUSTIC SEALANT

CONT DEFLECTION TRACK

FASTENED TO STRUCTURE

ABOVE

FASTEN GYP BOARD TO

LOWER DEEP LEG TRACK

ONLY TO ALLOW FOR SLIP

CONNECTION

A-501

C2

A-501

C2

BASE AS SCHEDULED

ALUMINUM

STOREFRONT SYSTEM

BATT INSULATION

WALL AS SCHEDULED

BLOCKING

ROLLER TUBE AND SHADE

ASSEMBLY (MANUAL)

METAL THRESHOLD W/

GASKET ON UNDERSIDE

SEALANT BED

FINISH AS SCHEDULED ON

EXISTING RAISED FLOOR

SYSTEM

FIRE CAULK [ACOUSTIC

SEALANT FOR INTERIOR

SOUND PARTITIONS]

GYP WALL BOARD ON MTL

STUD FRAMING. SEE PLAN.

BATT INSULATION

DOOR AS SCHEDULED

/2

M

A X

DOOR FRAME BEYOND

EXISTING SLAB

FIRE CAULK [ACOUSTIC

SEALANT FOR INTERIOR

SOUND PARTITIONS]

METAL THRESHOLD W/

GASKET IN SEALANT BED.

ACOUSTIC SEALANT

FINISH AS SCHEDULED ON

EXISTING RAISED FLOOR

SYSTEM

ACOUSTIC SEALANT

WALL AS SCHEDULED

BATT INSULATION

DOOR AS SCHEDULED

DOOR FRAME BEYOND

EXISTING SLAB

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

SHEET OF

T H

S P

A C

E W

IN

G

C C

A F

S F

L

C O

N T

R A

C T

N

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

D E

L

IV

E R

Y O

R D

E R

N O

C

K D

B Y x

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

T R

A C

E S

T E

C H

N

IC

A L R

A N

G E

A R

C H

IT

E

C T

U R

A L E

N G

IN

E

E R

IN

G

S E

R V

IC

E

S

A A rh o d e s b ri s i n d ic a te d

/2

/2

:5

:4

P

M

E R

S T

A R

S R

E L

O C

A T

IO

N

A-501

D E

T A

IL

S

D B

E H

-1

A -5

F A

-1

D

-0

A u g u s t

F A

F A

F A

-1 D

-0

D e s ig n e r

A u th o r

A p p ro v e r

C h e c k e r

1 1/2" = 1'-0"A-501

C2 BACKING DETAIL

1 1/2" = 1'-0"A-501

C4 DOUBLE ROLL-UP SHADES

3" = 1'-0"A-501

A2

WALL TO MULLION

CONNECTION DTL

1 1/2" = 1'-0"A-501

A1 WALL SECTION

1 1/2" = 1'-0"A-501

C3 HEADER DETAIL

3" = 1'-0"A-501

A3 SILL DETAIL - RATED / ACOUSTIC PARTITION

3" = 1'-0"A-501

A5 TYPICAL SILL DETAIL

jrb30077 Cloud+ jrb30077 Cloud+ Use full metal backing at dimension shown in AV Elevations.

A

B

B

C

C

D

D

E

E

F

F

STAIR 1

ELEV

2RP3

2PP1

EPO EQUIPMENT

2UPS3

2RP2

2LP1

2PP2

2RP1

2SWB1

(2UPS3)-(2) (2RP2)-(8)

(2UPS3)-(4)

(2UPS3)-(6) (2RP2)-(6) (2UPS3)-(17)

(2UPS3)-(20)

(2RP2)-(2)

(2UPS3)-(7) (2UPS3)-(8)

(2UPS3)-(9) (2UPS3)-(10)

(2UPS3)-(11) (2UPS3)-(12)

(2UPS3)-(13) (2UPS3)-(14)

(2UPS3)-(19)

(2UPS3)-(22) (2UPS3)-(21)

(2UPS3)-(15)

(2UPS3)-(16)

(2RP2)-(10)

(2RP2)-(14)

(2RP2)-(12)

(2UPS3)-(18)

(2RP2)-(4)

G

(2UPS3)-(1,3,5)

OFFICE

205B

OFFICE

205C

OFFICE

205A

STARS USERS ROOM

DATA REDUCTION

CONTROL CENTER

204A

DATA REDUCTION

CENTER

OFFICE

FACILITY ELECTRICAL

JAN.

COMMUNICATIONS

MECHANICAL

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

SHEET OF

T H

S P

A C

E W

IN

G

C C

A F

S F

L

C O

N T

R A

C T

N

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

D E

L

IV

E R

Y O

R D

E R

N O

C

K D

B Y x

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

T R

A C

E S

T E

C H

N

IC

A L R

A N

G E

A R

C H

IT

E

C T

U R

A L E

N G

IN

E

E R

IN

G

S E

R V

IC

E

S

A A rh o d e s b ri

/8

/2

/2

:1

:5

P

M

E R

S T

A R

S R

E L

O C

A T

IO

N

E-103

E L

E C

T R

IC

A

L R

E C

E P

T A

C L

E P

L A

N

D B

E H

-1

E E

-1

F A

-1

D

-0

A u g u s t

F A

F A

F A

-1 D

-0

M G

O N

Z A

L E

Z

V

B A

D G

E T

T

A p p ro v e r

B

K O

L A

K

1/8" = 1'-0"

ELECTRICAL RECEPTACLE PLAN - SECOND FLOOR

GENERAL NOTES:

1. REFER TO PARTIAL SINGLE-LINE DIAGRAM ON SHEET E-601 FOR

EQUIPMENT, CONDUCTOR AND CONDUIT INFORMATION.

2. REFER TO PANEL SCHEDULES ON SHEET E-701 FOR CIRCUIT BREAKER,

BRANCH CONDUCTOR AND CONDUIT INFORMATION.

3. ENSURE ALL CONDUITS LEAVING SECURED ROOMS 203 AND 204 AREA ARE

SEALED WITH 3 FEET OF LEAVING THE SPACE.

4. REFER TO POWER/LIGHTING LEGEND ON SHEET E-001 FOR RECEPTACLE

MOUNTING TYPES.

5. LOCATIONS FOR DRC AND SUR WORKSTATION CIRCUITS 2UPS-7 THROUGH

2UPS-16 ARE NOTIONAL, FINAL LOCATION TO BE DETERMINED BASED ON

FINAL FURNITURE PLAN. COORDINATE FINAL LOCATION WITH CONTRACTING

OFFICER.

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

KEY NOTES:

1. MOUNT FIRST AND SECOND ROW OF VIDEO WALL RECEPTACLES 65 AND 92

INCHES AFF RESPECTIVELY, MEASURED FROM CENTER OF RECEPTACLE

BOX.

jrb30077 Cloud+ jrb30077 Cloud+ Change from (8) quad outlets to (10) duplex outlets behind monitors. Locate outlets based on AV Elevation Drawing.

jrb30077 Cloud+ jrb30077 Cloud+ Change from (1) quad outlet to (1) duplex outlet behind monitors. Locate outlets based on AV Elevation Drawing.

V

T V

T V

T V

T V

T V

T V

T V

T V

T V

C

T V

T V S

S

S

S

A

A

B

B

C

C

D

D

E

E

F

F

STAIR 1

VIDEO WALL 2

OFFICE

205B

OFFICE

205C

OFFICE

205A

STARS USERS ROOM

DATA REDUCTION

CONTROL CENTER

204A

DATA REDUCTION

CENTER

OFFICE

FACILITY ELECTRICAL

JAN.

COMMUNICATIONS

STAIR 1

ELEV

MECHANICAL

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

SHEET OF

T H

S P

A C

E W

IN

G

C C

A F

S F

L

C O

N T

R A

C T

N

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

D E

L

IV

E R

Y O

R D

E R

N O

C

K D

B Y x

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

T R

A C

E S

T E

C H

N

IC

A L R

A N

G E

A R

C H

IT

E

C T

U R

A L E

N G

IN

E

E R

IN

G

S E

R V

IC

E

S

A A rh o d e s b ri

/8

/2

/2

:1

:1

P

M

E R

S T

A R

S R

E L

O C

A T

IO

N

T-103

C O

M M

U N

IC

A

T

IO

N S

O U

T L

E T

P L A

N

D B

E H

-1

E T

-1

F A

-1

D

-0

A u g u s t

F A

F A

F A

-1 D

-0

M G

O N

Z A

L E

Z

V

B A

D G

E T

T

A p p ro v e r

B

K O

L A

K

KEY NOTES:

1. MOUNT FIRST AND SECOND ROW OF VIDEO WALL OUTLETS 65 AND 92

INCHES AFF RESPECTIVELY, MEASURED FROM CENTER OF OUTLET BOX.

2. INSTALL QTY 3, 1-1/2 INCH CONDUITS FROM ABOVE REFLECTED CEILING TO

CABLE TRAY UNDER RAISED FLOOR FOR FUTURE USE.

GENERAL NOTES:

1. INSTALL TEL/DATA, AUDIO VISUAL AND SPEAKER OUTLETS IN LOCATIONS

SHOWN. INSTALL 1 INCH CONDUIT FROM EACH WALL OR CEILING MOUNTED

BOX TO CABLE TRAY UNDER RAISED FLOOR. COMMUNICATION CABLING TO

BE INSTALLED BY OTHERS.

2. COORDINATE MOUNTING HEIGHT OF ALL WALL MOUNTED OUTLETS WITH

CONTRACTING OFFICER UNLESS OTHERWISE NOTED.

1/8" = 1'-0"

COMMUNICATIONS OUTLET PLAN - SECOND FLOOR

PLAN NORTH

04 8 16268

SCALE: 1/8"=1'-0"

jrb30077 Cloud+ jrb30077 Cloud+ Remove box for TV jrb30077 Cloud+ jrb30077 Cloud+ Remove box for TV jrb30077 Cloud+ jrb30077 Cloud+

1. Remove network drops from monitor wall

2. Back boxes in video wall should be double gang.

3. Conduit from underfloor cable tray to back boxes should be 2-inch diameter

4. In lieu of (8) back boxes show, a total of (10) back boxes should be installed.

5. Refer to AV Elevation drawing

Sheets
G-001 - COVER SHEET
G-002 - SHEET INDEX
G-003 - PROJECT DATA
A-001 - LIFE SAFETY PLAN
A-002 - REFERENCE PLAN
AD-101 - DEMOLITION FLOOR PLAN
A-101 - FLOOR PLAN
A-102 - REFLECTED CEILING PLAN
A-103 - EQUIPMENT PLAN
A-201 - BUILDING SECTIONS
A-202 - PARTIAL ELEVATIONS
A-501 - DETAILS
A-601 - OPENING SCHEDULES AND DETAILS
A-701 - FINISH PLAN
M-001 MECHANICAL GENERAL NOTES
M-002 MECHANICAL ABBREVIATIONS
M-003 MECHANICAL LEGEND
M-101 MECHANICAL DEMO PLAN - 1
M-102 MECHANICAL DEMO PLAN - 2
M-103 MECHANICAL FLOOR PLAN -1
M-104 MECHANICAL FLOOR PLAN -2
M-105 MECHANICAL PLAN - RAISED FLOOR
M-501 MECHANICAL DETAILS I
M-502 MECHANICAL DETAILS II
M-601 MECHANICAL SCHEDULES
M-901 MECHANICAL DIAGRAMS I
M-902 MECHANICAL DIAGRAMS II
E-001 ELECTRICAL GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
E-101 ELECTRICAL DEMO PLAN
E-102 EQUIPMENT POWER PLAN
E-103 ELECTRICAL RECEPTACLE PLAN
E-104 LIGHTING PLAN
E-501 ELECTRICAL DETAILS
E-601 SINGLE LINE DIAGRAM
E-701 PANEL SCHEDULES
FA-001 FIRE ALARM GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
FA-101 FIRE ALARM DEMO PLAN
FA-102 FIRE ALARM FLOOR PLAN
FA-601 FIRE ALARM RISER DIAGRAM
T-001 COMM GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
T-101 COMM DEMO PLAN
T-102 CABLE TRAY PLAN
T-103 COMMUNICATIONS OUTLET PLAN
T-104 COMMUNICATION CEILING PLAN