This document provides specifications for architectural, mechanical, electrical and fire protection work required to relocate equipment and personnel offices from Facility 1704 to Facility 85125, Rooms 203, 204 and 205 at Cape Canaveral Air Force Station in Florida. The solicitation number is FA252120B0005 and is seeking a contractor to provide labor, equipment and materials to complete the relocation in accordance with the drawings and specifications. Key aspects of the work include demolishing existing walls and ceilings, installing new partitions, upgrading mechanical, electrical and fire systems, and reconfiguring work areas. The required products and services include architectural, interiors, mechanical, fire protection and electrical construction. The federal agency issuing this opportunity is the Department of the Air Force Space Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Abstract - ER STARS 24Mar2020.pdf | ||
| Solicitation Amendment FA252120B00050002 SF 30.pdf | ||
| HVAC Schematic Pics.pdf | ||
| Solicitation Amendment FA252120B00050001.pdf | ||
| Updated WD FL20200001 (21Feb 2020).pdf | ||
| STARS MECH. RM 221 Pictures.pdf | ||
| Site Visit Q and A.pdf | ||
| Attach 10- WD FL20200001 (31 Jan 2020).pdf | ||
| Solicitation - FA252120B0005.pdf | ||
| Attach 8 - Drawings-100% AV SYSTEM MODIFICATIONS.pdf | ||
| Attach 12 - KTR Hazardous Waste Generation Form.doc | DOC document | |
| Attach 5- Drawings FIRE ALARM 8-29-19.pdf | ||
| Attach 3- Drawings COMM 8-29-19.pdf | ||
| Attach 1-Design Specification.pdf | ||
| Attach 4- Drawings ELECTRICAL 8-29-19.pdf | ||
| Attach 6- Drawings MECHANICAL 8-29-19.pdf | ||
| Attach 2- Submittal Register.xlsx | XLSX spreadsheet | |
| Attach 9- CCAFS Stars - AV Elevations.pdf | ||
| Attach 11 - 45 SFS Badge Request Form.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE RD 401
SKID STRIP
B A
N A
N A
R
I V
E R
B A
N A
N
V
E R
A T
L A
N T
I C O
C E
A N
A T
L A
N T
C
O
E
A N
PORT CANAVERAL
CCAFS
INDUSTRIAL AREA
TO
KENNEDY SPACE CENTER
INDUSTRIAL AREA
SOUTH GATE
PASS & ID
CAPE CANAVERAL
AIR FORCE
STATION
67750
38200
75251
70510
34705
69800
70000
01115
01063
33000
38835
01348
05501
01385
70580
05401
55820
08801
10905
07000
70659
34715
85125
27220
62615
62700
21934
15730
10751
13122
18800
55810
62637
36001
43407
01118
56940
90302
56620
70653
28402
07803
45601
01777
01062
73700
29145
70503
47109
62630
55895
77800
29407
57512
63000
43400
08605
55855
38315
36009
29201
62820
52003
01366
29403
70451
38800
62980 62960
62610
62990
88900
03100
70650
51900
57511
29204
57105
74100
01360
33007
29150
07001
01428
15507
70540
29138
50803
90329
38804
40906
67901
90326
90327
67400
18705
28501
56944
90328
85200
29402
69805
01069
56921
50801
01064
01047
35420
43302
08803
01117
81550
05912
07800
73720
68220
33006
13112
33002
79150
59930
56632
67900
10911
44200
61900
80540
29137
01061
38805
20185
01050B
05951
90305
05403
55871
29205
88925
34706
17766
67210
10700B
01040C
01381
55893
70512
55865
01361
62720
55815
55840
34724
13010
47105
73020
05550
41111
41109
07007
29404
17768
62735
17702
88940
17703
52001
01068
62640
80520
28401
01061
01042
44205
04100
88911
72650
70535
13125
80505
01066
72810
47104
61820
73701
15820
99999
02841
72910
66505
40431
01102
04140
24401
01207A
18806
01044
24450
01663
56949
92021
47118
77610
29148
05502
78150
74600
74602
74601
41113
17781
01664
61830
36004
29147
38201
01532
62708
70663
77200
07200
17756
47120
29142
99999
27206
01046
99999
67740
28420
21805
99999
85201
50166
17790
99999
21935
70520
90418
72709
47137
72665
70011
47110
72680
70012
99999
47115
28425
29125
61875
99999
90518
55829
51906
77602
02805
47111
70499
01052
29210
72708
72702
72703
77611
34500
50211
90313
01246
01244
01245
03113
92020
28414
59925
01221
41110
47127
55850
99999
18008
85202
56618
28422
99999
90534
K8-1699
41303
44210
01307
67500
33012
17770
72701
56636
01048
24404
92019
38801
56928
70018
77350
55826
29406
29206
80700J
28502
01346
01247
17705
06011
80700K
51912
72707
01207G
01051
28411
90516
01243
05959
38833
34702
01241
63803
63804
41302
45602
85306
85307
01260
56939
17704
38804
51903
56638
28409
89002
69801
24405
70557
51915
32911
28403
05914
90400
85625
38814
05504
9999999999999999999999999
36665
28504
07805
70662
70558
38808
38105
13114
47138
10831
20299
99999
92005
24448
54715
15832
36003
56616
43311
92007
28413
03104
99999
K8-0600
28415
99999
22010
56926
75265
38316
36002
88931
29126
38810
56930
33015
56621
17754
67916
56617
55851
66510
90314
43313
85402
70013
99999
56624
70507
88913
81565
99999
63806
81551
24451
99999
10907
85128
07700
10915
07003
43408
25324
24445
08806
M7-1098
47108
05414
20187
01039
03114
99999
21803
01116
78710
85203
41107
41108
99999
01040A
28421
17752 17753
17755
15603 15603
24403
62707
56948
01050A
17773
15541
34716
01207H
70017
15641
90320
70526
01400
72700
07202
29405
63805
03110
70528
99999
99999
05952
55837
85308
52002
99999
56020
99999
99999
99999
99999
92016
99999
01207M
99999
99999
72706
99999
99999
29118
99999
70658
41301
73706
47102
01240
27212
04120
21915
29144
29120
28423
62633
29135
47131
29136
47132
17706
08807
02826
01207J
29134
57515
01215
80700A
99999
01248
69804
18413
15303
01207F
18408
01242
99999
07006
03112
32347
56629
M7-1150
99999
51908
79090
79180
70021
05961
50210
29115
99999
38202
60000
99999
15309
90530
99999
01055
99999
23604
33014
08809
99999
99999
99999
99999
79125
55894558945589455894
18412
62865
07705
99999
88933
01207E
99999
75250
07850
50225
08610
03106
88941
99999
99999
79103
56625
03109
07701
07848
99999
99999
99999
99999
38830
29139
99999
41905
99999
42911
99999
08814
99999
05603
03102
99999
99999
99999
50216
99999
38807
15611
47150
02842
28404
12905
99999
15610
15608
15609
08602
70586
99999
99999
99999
99999
55817
28407
62701
99999
22005
99999
85628
99999
28408
15305
99999
85309
99999
85702
47117
77608
03122
29181
13128
99999
99999
60688
99999
88932
41306
90312
07702
55842
90300
99999
99999
50702
46711
99999
99999
99999
47140
91921
22100
56623
40432
99999
99999
18803
03135
21803
72711
70534
03117
99999
24606
99999
99999
K8-0590
41500
00216
03118
90525
99999
99999
42949
34725
99999
99999
99999
99999
63301
99999
16901
9999999999999999999999999
77630
40602
99999
99999
99999
999999999999999
34707
41307
M7-1098A
99999
02810
74710
85630
99999
99999
15304
999999999999999
66250
01726
60680
01704
01728
01725
01641
50012
01744
01721
60530
01739
01731
01645
66330
60550
44600
01733
60650
49635
01748
54915
44410
49639
01724
54800
60705
55005
66310
49750
01726
54815
01740
01635
44625
55010
54850
60510
01722
66220
49816
44645
66336
60748
39762
49835
44401
60709
60505
54820
66242
01625
49536
55000
55001
49800
54928
60600
66232
60501
44700
54938
54805
66249
44603
66240
60640
60740
01723
44440
66340
54731
54732
66320
60408
44633
99999
49641
54733
66221
49760
44635
01794
55073
44500
44652
01646
01734
60540
54730
60425
55040
60306
60305
66251
60535
54905
60723
60302
01637
60719
49637
66200
60683
54939
60630
55071
49645
60303
44524
60533
54926
49535
49735
60500
99999 99999 99999 99999 99999
54935
54927
66266
99999 99999 99999 99999 99999
60534
55045
99999
99999 99999 99999 99999
66259
55065
44606
44501
44547
99999 99999 99999 99999 99999
54816
99999 99999 99999 99999
49505
60541
60629
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
66212
44638
54811
99999 99999 99999 99999 99999
44638 44638 44638 44638
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
55041
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
66257
99999
99999
99999
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
54739
99999 99999 99999 99999 99999
54814
44537
99999 99999 99999 99999 99999
99999 99999
60537
54812
44648 44648 44648 44648 44648
99999 99999 99999 99999 99999
99999 99999 99999
54945
60687
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
99999 99999 99999
99999 99999 99999 99999 99999
44654
44615
99999 99999 99999 99999 99999
99999 99999 99999 99999 99999
49638
99999 99999 99999 99999 99999
STATE RD 401 B
A
S
IN
R D
PATROL RD S
H O
U N
D D
O G
C
IR
C L
E
M A
C A
R D
S P
IN
T
E S
T R
D
S A
M U
E L C
P H
IL
L
IP
S
P K
W Y
LIGHTHOUSE RD
S K
Y B
O L
T R
D
BUM
PER RD
P
IE
R R
D
FSA 5 RD
MISSION CONTROL RD
F
LIG
H T C
O N
T R
O L R
D
IR
B M
R D
LIGHTHOUSE RD
L
IG
H T H
O U
S E R
D
O B
S E R
V A T
IO
N R
D
C A M
E R
A R
D A
LP
H
A
C O
N
TR
O
L TO
W
ER
RD
C A M
E R
A R
D B
R A V O
T
IM
IN
G
R D
C E N
T R
A L C
O N
T R
O L R
D
A R
M O
R Y R
D
A Z U
S A R
D
S K
I D S
T R
I P R
D E
M E
R C
U R
Y G
E M
IN
I R
D
C E N
T R
A L C
O N
T R
O L R
D
S A
M U
E L
IN
D
U S
T R
Y R
D
H A N
G A
R R
D
TIT
A
N
III R
D
N A S A C
S W
Y E
T
IT
A N
III R
D
L O
O P
R D
TEST R
D
IC
B
M R
D
F R
E E
D O
M
R
D
B E
A C
H R
D
PATROL RD
S A
M U
E L
C P
H
IL
L
IP
S P
K W
Y
T
IT
A N
I
II
R D
CENTAUR RD
ROCKET RD
S A
M U
E L
C P
H
IL
L
IP
S P
K W
Y
BOUNDARY RD
P
IE
R R
D
H
EA
V Y L
A U
N C
H R
D
FLIGHT CONTROL RD
P
IE
R R
D
OLD
SPIN TEST
FACILITY
MSA #5
CAMERA
PAD #21
SR 528 BEACHLINE
SR A1A TO COCOA BEACH
FSA #1
C
P H
IL
L
IP
S
P K
W Y
HGR
C
LIGHT
HOUSE
PROJECT LOCATION
DBEH 18-1690
FACILITY 85125
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
C O
N T
R A
C T
N
D
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T H
S P
A C
E W
IN
G
C C
A F
S F
L
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri to
H
T
E
S
/2
/2
:5
:0
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
G-001
C O
V E
R S
H E
E T
D B
E H
-1
G G
-0
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
DBEH 18-1690
ER STARS RELOCATION
1 : 24000G-001
A2 LOCATION PLAN
CAPE CANAVERAL AIR FORCE STATION
CAPE CANAVERAL, FLORIDA
TRUE
NORTH
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/2
/2
:5
:0
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
G-002
S H
E E
T I N
D E
X
D B
E H
-1
G -0
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
GENERAL
Current Revision
Sheet Number Sheet Name
G-001 COVER SHEET
G-002 SHEET INDEX
G-003 PROJECT DATA
ARCHITECTURAL
A-001 LIFE SAFETY PLAN
A-002 REFERENCE PLAN
AD-101 DEMOLITION FLOOR PLAN
A-101 FLOOR PLAN
A-102 REFLECTED CEILING PLAN
A-103 EQUIPMENT PLAN
A-201 BUILDING SECTIONS
A-202 PARTIAL ELEVATIONS
A-501 DETAILS
A-601 OPENING SCHEDULES AND DETAILS
A-701 FINISH PLAN
MECHANICAL
M-001 MECHANICAL GENERAL NOTES
M-002 MECHANICAL ABBREVIATIONS
M-003 MECHANICAL LEGEND
M-101 MECHANICAL DEMO PLAN - 1
M-102 MECHANICAL DEMO PLAN - 2
M-103 MECHANICAL FLOOR PLAN - 1
M-104 MECHANICAL FLOOR PLAN - 2
M-105 MECHANICAL PLAN - RAISED FLOOR
M-501 MECHANICAL DETAILS I
M-502 MECHANICAL DETAILS II
M-601 MECHANICAL SCHEDULES
M-901 MECHANICAL DIAGRAMS I
M-902 MECHANICAL DIAGRAMS II
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS
E-101 ELECTRICAL DEMO PLAN
E-102 EQUIPMENT POWER PLAN
E-103 ELECTRICAL RECEPTACLE PLAN
E-104 LIGHTING PLAN
E-501 ELECTRICAL DETAILS
E-601 SINGLE LINE DIAGRAM
E-701 PANEL SCHEDULES
FIRE ALARM
FA-001 FIRE ALARM GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS
FA-101 FIRE ALARM DEMO PLAN
FA-102 FIRE ALARM FLOOR PLAN
FA-601 FIRE ALARM RISER DIAGRAM
TECHNOLOGY
T-001 COMM GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS
T-101 COMM DEMO PLAN
T-102 CABLE TRAY PLAN
T-103 COMMUNICATIONS OUTLET PLAN
T-104 COMMUNICATION CEILING PLAN
DRAWING ABBREVIATIONS INDEX OF DRAWINGS
NUMBERING SYSTEM:
A2.10/01
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
ID - INTERIOR DESIGN
SERIES NUMBER
SHEET NUMBER WITHIN
SERIES
NUMBER OF PLAN, DETAIL,
ETC. ON SHEET
A ---------------------
A LABELCLASS A DOOR
A/C AIR CONDITION
A/C UNITAIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNLACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWP ACOUSTICAL WALL PANEL
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABELCLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABELCLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABELCLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED
INSTALLED BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
U --------------------
UNO UNLESS NOTED OTHERWISE
LEGEND
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
SPRAY FOAM INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR CEMENT
BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
MATERIALS
ANNOTATION CALLOUTS/DRAWING SYMBOLS
CEILING SYMBOLS
GRID / COLUMN
LINE
DESIGNATOR
DOOR NUMBER
INTERIOR ELEVATION
1i
WALL TYPE
WINDOW TYPE
A101
SIM
SECTION
Room name
101 ROOM NAME/NUMBER
A101
Ref
A101
Ref
EXTERIOR ELEVATION
1 REVISION TAG
A-101
SIM
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW w/
TRUE NORTH
INDICATION
SPOT ELEVATION
Name
Elevation
FLOOR LEVEL & NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A
EGRESS ROUTE ID
AND SECTION
LENGTH
SHEET KEYNOTE
Room
Rm_Occupancy
150 SF
EGRESS :Egress_ID
Egress_Length
ROOM OCCUPANCY
& AREA
GENERAL NOTES
GENERAL INSTALLATION NOTES:
1. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH PROJECT
DRAWINGS AND SPECIFICATIONS; FOR PURPOSES OF CLARIFICATION
THE WORD 'PROVIDE' MEANS PROVIDE AND UNLESS NOTED
OTHERWISE.
2. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED
TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR
SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A
DIFFERENT DETAIL IS SHOWN.
3. ALL REFERENCES TO MANUFACTURER NAMES ARE FOR IDENTIFICATION
ONLY; THE REFERENCES ARE NOT INTENDED TO LIMIT SELECTION OF
SIMILAR ITEMS FROM OTHER MANUFACTURERS WITH APPROVAL OF
CONTRACTING OFFICER.
4. SEE FINISH SCHEDULE FOR ADDITIONAL INFORMATION ON FINISHES
AND MATERIALS.
5. ALL CONSTRUCTION REQUIREMENTS INCLUDING ENVIRONMENTAL
ASBESTOS AND HEAVY METAL DEMOLITION SHALL BE COORDINATED
WITH THE CONTRACTING OFFICER.
6. AFTER COMPLETION OF CONSTRUCTION WORK, ALL WORK AREAS
SHALL BE LEFT CLEAN AND FREE OF ANY EXTRANEOUS JOINT
COMPOUND, PLASTER, STUCCO, PAINT SMEARS OR SPLATTERS AND
STAINS.
7. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION,
WHEREVER WORK IS TO BE PERFORMED IN FINISHED/OCCUPIED
SPACES TO PREVENT DAMAGE TO ADJACENT AREAS, EQUIPMENT, OR
FURNISHINGS; TO PREVENT ACCIDENTAL INJURY TO BUILDING
OCCUPANTS AND THE PUBLIC; TO PREVENT THE SPREADING OF DUST,
DIRT, DEBRIS, AND MOISTURE FROM THE AREA WHERE WORK IS BEING
PERFORMED; AND TO PREVENT DUST, DIRT, DEBRIS, AND MOISTURE
FROM GETTING ON OR IN THE BUILDING OCCUPANTS FURNISHINGS OR
EQUIPMENT. CONTRACTOR SHALL PROVIDE METHOD/CONSTRUCTION
OF DUST CONTROL/BARRIER TO THE CONTRACTING OFFICER FOR
APPROVAL PRIOR TO START OF DEMOLITION WORK.
8. THE CONTRACTOR SHALL REPAIR, AT NO COST TO THE OWNER, ANY
DAMAGE DONE BY HIMSELF OR HIS EMPLOYEES. CONTRACTOR SHALL
ALSO BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED TO
PROPERLY INSTALL ITS WORK.
DISSIMILAR METALS:
CONTRACTOR SHALL PROVIDE ADEQUATE SEPARATION OF DISSIMILAR METALS
BY APPROPRIATE MEANS, SUCH AS 15# SEPARATION FELT AND ASPHALTIC
TAPE OR ASPHALTIC PAINT AS REQUIRED.
ALL CONNECTORS, FASTENERS, BOLTS, ETC., SHALL BE SELECTED IN ORDER
TO PREVENT OR MINIMIZE ANY GALVANIC REACTION BETWEEN DISSIMILAR
METALS. UNLESS OTHERWISE NOTED PROVIDE STAINLESS STEEL.
SEQUENCING OF WORK:
CONTRACTOR SHALL SEQUENCE DEMO AND NEW WORK TO FULLY COMPLETE
ALL REQUIRED CONSTRUCTION WORK. PHASED CONSTRUCTION IS ACCEPTABLE
WHERE APPROVED BY THE CONTRACTING OFFICER. CONTRACTOR SHALL
PROVIDE ADEQUATE PROTECTION OF NEW AND EXISTING ASSEMBLIES AGAINST
INCLEMENT WEATHER AND CONSTRUCTION DAMAGE.
MINERAL FIBER
BLANKET INSULATION
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/1
/2
/2
:5
:0
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
G-003
P R
O J E
C T
D A
T A
D B
E H
-1
G G
-0
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
R R
G M
R R
W
BUILDING SUMMARY
PROJECT INFORMATION
PROJECT NAME: DBEH 18-1690 ER STARS RELOCATION
ADDRESS: 45SW CCAFS HEADQUARTERS (HQ) BUILDING (FACILITY 85125), CCAFS, FL 32920
PROPOSED USE: CONTROL ROOM
OWNER-CONTACT PERSON: CORY COOPER
PHONE: 321-853-9718
APPLICABLE CODES
- BUILDING CODE: IBC 2015
- MECHANICAL: IMC 2015
- PLUMBING: IPC 2015
- ELECTRICAL: NFPA NEC 2014.
- FIRE CODE: IBC 2015
- STATE/CITY AMENDMENTS: FL
- LIFE SAFETY CODE: NFPA 101 2018
- ACCESSIBILITY: ADA 2010
- ENERGY CODE: ASHRAE STANDARDS 90.1
BUILDING PLANNING
OCCUPANCY: B, BUSINESS
MIXED OCCUPANCY? YES / NO
REQUIRED FIRE SEPARATION: NO
TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: IIB
GENERAL BUILDING LIMITATIONS
- HEIGHT OF BUILDING: N/A
- NUMBER OF STORIES: 2
- TOTAL RENOVATED AREA: 2,370 FT2
- MAX. TOTAL AREA OF BUILDING: N/A
- PENTHOUSE AND ROOF STRUCTURE: N/A
- HIGH RISE: YES / NO
- PARKING SPACES PROVIDED: N/A
- PARKING SPACES REQUIRED: N/A
- ACCESSIBLE PARKING SPACES PROVIDED: N/A
FIRE PROTECTION SYSTEMS
- FIRE EXTINGUISHING SYSTEM: YES / NO
- STANDPIPE SYSTEM: YES / NO TYPE N/A
- SMOKE CONTROL: YES / NO CLASS N/A
FIRE RESISTANT CONSTRUCTION SCHEDULE
ITEM REQ'D RATING / HR UL/FM # WHERE APPLICABLE
- EXTERIOR WALLS:LOAD BEARING
- FIRE/PARTY WALLS
- SHAFTS
- TENANT SEPARATION
- INTERIOR WALL: LOAD BEARING
- COLUMNS
- BEAMS
- FLOOR/CEILING
- ROOF/CEILING
X
ESSENTIAL FACILITY (IBC TABLE 1604.5)
ESSENTIAL FACILITY? YES / NO
X
X
X0
X
X
X
X
X
X
X
DESIGN GUIDELINES
- UFC 1-200-01 DESIGN. GENERAL BUILDING REQUIREMENTS
- AFMAN 32-1084 FACILITY REQUIREMENTS
- AIR FORCE CORPORATE FACILITIES STANDARDS [AFCFS]
- AF CORPORATE FACILITIES STANDARD (AFCFS)
FIRE EXTINGUISHER
PATH OF EGRESS
DIRECTION OF
EGRESS PATH
TRAVEL DISTANCE TO
NEAREST BUILDING EXIT
T.D. x'-x"
EGRESS CAPACITY
IBC 1005.3.1, 1005.3.2,
EXIT AND MEANS OF EGRESS WIDTH
F L O
O R
O C
C U
P A
N T
L O
Q U
IR
E
D S
T A
IR
W
A Y
W
ID
T H
P E
R E
A C
H S
T A
IR
D E
S
IG
N S
T A
IR
W
A Y
W
ID
T H
R E
Q U
IR
E
D D
O O
R A
N D
L E
V E
L C
O M
P O
N E
N T
S
D E
S
IG
N D
O O
R W
ID
2 16 N/A N/A .2"X 16= 3.2"
32"
MIN.
92"
TOTAL
COMMON PATH OF EGRESS
IBC TABLE 1006.2.1
EXIT ACCESS TRAVEL
IBC TABLE 1017.2
MAX DEAD END CORRIDOR
IBC 1020.4
BUSINESS B : 50 FT SPRINKLED
MEANS OF EGRESS
REQUIRED
WIDTH OF EXIT PROVIDED = 32" PER DOOR LEAF
ADDITIONAL REQUIREMENTS
E L E
V A
T O
R S
S P
R
IN
K L E
R S
S M
O K
E D
E T
E C
T
IO
N
L
IG
H T
IN
G
P E
R N
A T
IO
N
A L E
L E
C T
R
IC
L
D E
S A
N
IT
A T
IO
N
P E
R N
A T
IO
N
A L P
L U
M B
IN
G
C O
D E
YES YES YES
R O
O F
C O
V E
R
IN
G S
- YES -
V E
N T
IL
A
T
IO
N P
E R
A S
H R
A E
S T
A N
D A
R D
YES
C L A
D D
IN
G
A N
D C
O M
P O
N E
N T
S
MAXIMUM FLOOR AREA ALLOWANCE - NFPA 101
OCCUPANCY SINGLE/MULT
OCCUPANCY
GROSS
FLOOR AREA
FLR AREA PER
OCCUPANT-SPRK
OCCUPANT
LOAD
BUSINESS: B
SINGLE
OCCUPANCY
2,370 SF 150 GROSS SF 16
OCCUPANT LOAD
SYMBOL LEGEND
MEANS OF EGRESS
IBC CH. 10
SPRINKLED: 100'-0"
SPRINKLED: 300'-0"
FE
FIRE EXTINGUISHER CABINETFEC
T.D. 96'-0"
PERSONS
REQUIRED
PROVIDED
1.6"
32"
T .D
PERSONS
REQUIRED
PROVIDED
1.6"
32"
T .D
BUSINESS 'SUITE' (HATCHED AREA)
AREA: 2370 FT2
LOAD FACTOR: 150
OCCUPANT LOAD: 16
STAIR
STAIR
FEFEFE
LIMITS OF SCOPE OF
WORK
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri s i n d ic a te d
/2
/2
:5
:1
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-001
L
IF
E S
A F
E T
Y P
L A
N
D B
E H
-1
A I
A -0
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
E G
R E
S S
R O
U T
E P
L A
N
C h e c k e r
3/32" = 1'-0"A-001
A1 SECOND FLOOR LIFE SAFETY PLAN
PLAN NORTH
NOTES:
OCCUPANCY AND USE REMAINED AS IS; PLUMBING FIXTURE COUNT AND EGRESS
CAPACITY REMAINED UNCHANGED.
A. EXISTING OCCUPANT LOAD: 24 OCCUPANTS
B. PROPOSED OCCUPANT LOAD: 16 OCCUPANTS
A B C D E F
LIMITS OF SCOPE OF
WORK
DATA REDUCTION
CENTER
DATA REDUCTION
CONTROL
CENTER
204A
STARS USERS
ROOM
OFFICE
205C
OFFICE
205B
OFFICE
OFFICE
205A
FACILITY
ELECTRICAL
JAN.
COMMUNICATIONS
MECHANICAL
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/3
/2
/2
:5
:1
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-002
R E
F E
R E
N C
E P
L A
N
D B
E H
-1
A -0
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
3/32" = 1'-0"A-002
A1 SECOND FLOOR REFERENCE PLAN
PLAN NORTH
02 4 8134
SCALE: 1/4"=1'-0"
B C D E
D01
D02
D03
D03
D04
D04
D05
OFFICE OPEN OFFICE
D05
D06
D08
D08
D02
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/4
/2
/2
:5
:4
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
AD-101
D E
M O
L
IT
IO
N
F L O
O R
P L A
N
D B
E H
-1
A D
A D
-1
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1/4" = 1'-0"AD-101
B1 SECOND FLOOR DEMOLITION PLAN
PLAN NORTH
02 4 8134
SCALE: 1/4"=1'-0"
GENERAL NOTES - DEMOLITION
A PRIOR TO STARTING WORK, CONTRACTOR SHALL COORDINATE
DESIGN DRAWINGS WITH EXISTING FIELD CONDITIONS. IF THERE IS
ANY DISCREPANCY BETWEEN THE DRAWINGS AND THE EXISTING
CONDITIONS, THE CONTRACTOR SHALL NOTIFY IN WRITING TO THE
CONTRACTING OFFICER AND ARCHITECT, TYP
B CAP ALL ABANDONED UTILITIES BELOW FLOOR, ABOVE CEILING OR AS
INDICATED ON DRAWING
C ALL REMOVED EQUIPMENT SHALL BE SAVED FOR INSPECTION BY
CONTRACTING OFFICER FOR REUSE OR SALVAGE. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR DISPOSAL
D CONTRACTOR SHALL PROVIDE SEISMIC RESTRAINTS FOR ALL
MECHANICAL, PLUMBING AND ELECTRICAL SYSTEMS.
E CONTRACTOR SHALL FURNISH MATERIAL, EQUIPMENT AND LABOR TO
PATCH THE FLOOR AND REPAIR THE WALL AND CEILING TO MATCH
THE ADJACENT EXISTING SURFACES AFTER INSTALLATION AND
INSPECTION AS APPROVED
F THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTINUOUS CLEAN
UP OF THE SITE OF ALL DEBRIS, WHETHER CREATED BY HIS WORK OR
THE FAILURE OF HIS SUBCONTRACTOR TO CLEAN UP AFTER THEIR
WORK
G ALL LIFE/SAFETY EQUIPMENT DISTURBED BY NEW CONSTRUCTION
SHALL BE REINSTALLED
H CONTRACTOR SHALL PATCH AND REPAIR ALL DISTURBED SURFACES
AND FINISH TO MATCH EXISTING ADJACENT SURFACES
I CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK RELATED TO
AND REQUIRED BY THE INSTALLATION OF NEW PLUMBING,
ELECTRICAL AND THE MECHANICAL CONTRACTOR SHALL DETERMINE
SIZE AND INSTALLATION METHOD OF NEW SYSTEMS. ALL WORK SHALL
MEET GENERALLY ACCEPTED STANDARD OF CARE FOR THIS TYPE
AND COMPLEXITY OF CONSTRUCTION
J TEMPORARY DUST BARRIERS SHALL BE PROVIDED SUFFICIENT TO
MAINTAIN A DUST FREE ENVIRONMENT WITHIN THE BUILDING
K IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT NO
EMERGENCY EXIT IS BLOCKED AT ANY TIME
L ALL OPENINGS IN FLOOR AND WALLS RESULTING FROM THE REMOVAL
OF EQUIPMENT, PIPES, CONDUITS SHALL BE COMPLETELY REPAIRED.
OPENINGS IN FLOOR SHALL BE FILLED WITH A CEMENTIOUS MATERIAL
COMPATIBLE WITH THE EXISTING FLOOR ASSEMBLY
M ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH APPLICABLE
LOCAL, STATE AND FEDERAL CODES
N THE CONTRACTOR SHALL FIELD SURVEY AND VERIFY EXISTING
CONDITIONS PRIOR TO STARTING ANY WORK
O THE CONTRACTOR SHALL ALLOW FOR ADDITIONAL DEMOLITION THAT
MAY NOT BE SHOWN, BUT ARE REQUIRED TO ACHIEVE THE FINISHED
RESULT, AS DESCRIBED ON DRAWINGS
P SURVEY FOR PRESENCE OF HAZARDOUS MATERIALS AND
ABATEMENT, IF FOUND. HAS TO BE COORDINATED WITH THE
CONTRACTING OFFICER PRIOR TO DEMOLITION
Q ITEMS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED
KEYNOTE - DEMOLITION
D01 DEMOLISH GYP BOARD WALL FINISH. RETAIN AND PREPARE
EXISTING LIGHT GAUGE FRAMING FOR REUSE. PATCH AND REPAIR
EXISTING RAISED ACCESS FLOOR AS NECESSARY
D02 DEMOLISH DOOR AND FRAME. REUSE DOOR IF POSSIBLE.
PREPARE ADJACENT SURFACES TO RECEIVE NEW WORK.
D03 MODIFY EXISTING RAISED FLOOR AS NECESSARY TO
ACCOMMODATE NEW PARTITION WALLS, SEE FLOOR
PLAN.CONTRACTOR TO TURN OVER ANY UNNEEDED FLOOR TILES
TO BUILDING 85125 FACILITY MANAGER.
D04 MODIFY,REMOVE OR SALVAGE FOR REUSE EXISTING ACOUSTICAL
CEILING TILE SYSTEM AS NECESSARY TO ACCOMMODATE NEW
CONSTRUCTION SUCH AS LIGHT FIXTURES,MECHANICAL
DUCTWORK, CEILING MOUNTED EQUIPMENT AND PARTITION WALLS
D05 DEMOLISH PORTION OF WALL TO ACCOMMODATE NEW DOOR. SEE
FLOOR PLAN FOR EXTENT.
D06 DEMOLISH EXISTING OVERHEAD PROJECTOR SCREEN AND
ASSOCIATED ACCESSORIES, ELECTRICAL CONDUITS, AND
STRUCTURAL SUPPORTS.
D08 REMOVE EXISTING FLOOR COVERING AND ADHESIVES FROM
EXISING RAISED FLOOR TILES AND PREP FOR NEW FINISHES.
COORDINATE WITH MANUFACTURER'S INSTRUCTIONS.
FLOOR PLAN LEGEND
WALLS
DOOR
REFER TO DOOR SCHEDULE
PARTITION TYPE INDICATOR
REFER TO PARTITION TYPES ON THIS SHEET
WINDOW TAG
REFER TO WINDOW TYPES
KEYNOTE
xx
NOTE: ALL ITEMS SHOWN IN THIS LEGEND MAY NOT APPLY TO THIS SHEET
B C D E
8'-11" 28'-11"
STAIR
OFFICE
205B
OFFICE
205C
OFFICE
205A
STARS USERS
ROOM
DATA REDUCTION
CONTROL
CENTER
204A
DATA REDUCTION
CENTER
205A
B
C
204A 204B
A-501
A2
FACILITY
ELECTRICAL
E
15 01
A-202
B5
A-202
B3
A-202
17'-10 5/8"
C2
E Q
E Q
E Q
E Q
E Q
E Q
E Q
OFFICE
C
A
B
7'-8"
A-202 A5B1 A-202
A1
A-202
A3
A-501
A2 Sim
A-501
A2 Sim
" 4
1'-6"
ALIGN
07 C1
D1
A-201
B1
A-201
A3
A-201
A1
A-201
C4
C3
A-202
B2
10'-0"
9'-4"
TYPE 2 FULL HEIGHT NON-RATED INTERIOR PARTITION
TYPE 3 NON-RATED INTERIOR PARTITION, GWB
TERMINATES AT 8" ABOVE CEILING TILE
PARTITION TYPES
5/8" GWB BOTH SIDES ON 3 5/8" MTL STUD
FRAMING AT 16" OC
5/8" GYP SOUND BOARD BOTH SIDES ON 6"
MTL STUD FRAMING AT 16" OC.
STC 45 [B.O.D. NGC 2013023]
SOUND ATTENUATION
SOUND ATTENUATION
TYPE 1 FULL HEIGHT NON-RATED INTERIOR PARTITION
5/8" GYP SOUND BOARD BOTH SIDES ON 3
5/8" MTL STUD FRAMING AT 16" OC
STC 45 [B.O.D. NGC 2013005]
SOUND ATTENUATION
TYPE 4 NON-RATED CHASE PARTITION, GWB
TERMINATES AT 8" ABOVE CEILING TILE
5/8" GYP SOUND BOARD ON ONE SIDE OVER
2 1/2" MTL STUD FRAMING
"8
TYPE 3 TYPE 2TYPE 4
STC 45
5/8" GWB ON MTL STUD
FRAMING AT 16" OC.
BASE AS SCHEDULED
CEILING AS
SCHEDULED
BASE AS SCHEDULED
CEILING AS
SCHEDULED
SOUND ATTENUATION
ACOUSTIC SEALANT
ACOUSTIC SEALANT
BASE AS SCHEDULED
CEILING AS
SCHEDULED
5/8" GWB BOTH SIDES
ON MTL STUD FRAMING
AT 16" OC
UNDERSIDE OF DECK UNDERSIDE OF DECK
UNDERSIDE OF
DECK
EXISTING RATED
PARTITION
EXISTING RAISED
FLOOR PANEL
UTILITY GROMET
EXISTING FLOOR
SLAB
MTL STUD KICKER
@ 8'-0" O.C. MAX
MTL STUD KICKER
@ 8'-0" O.C. MAX
EXISTING RAISED
FLOOR PANEL
EXISTING FLOOR
SLAB
MECH.
DUCTWORK
5/8" GYP SOUNDBOARD
BOTH SIDES ON MTL
STUD FRAMING AT 16"
OC
EXISTING RAISED
FLOOR PANEL
EXISTING FLOOR
SLAB
SOUND ATTENUATION
DEFLECTION TRACK
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri s i n d ic a te d
/2
/2
:5
:2
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-101
F L O
O R
P L A
N
D B
E H
-1
A A
-1
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
GENERAL NOTES - PLAN
A THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND SHALL
VERIFY THESE DRAWINGS WITH THE EXISTING FIELD
CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE
CONTRACTING OFFICER OF ANY ISSUES.
B CONFORM TO ALL APPLICABLE CODES FOR DEMOLITION AND
NEW WORK. FOR ADDITIONAL GENERAL NOTES, LEGENDS,
AND SCHEDULES REFER TO SHEET G002.
C CONTRACTOR TO PROVIDE ENGINEERED SHOP DRAWINGS
AND FL PRODUCT APPROVALS FOR REVIEW BY THE DESIGN
TEAM PRIOR TO FABRICATION OF ALL ASSEMBLIES.
D COORDINATE ALL SHUT-DOWNS IN UTILITY SERVICE WITH THE
CONTRACTING OFFICER PRIOR TO PERFORMING SHUT-DOWNS
IN UTILITY SERVICE.
E MAINTAIN THE CONTINUITY OF CONSTRUCTION OF ALL
FIRE-RATED ASSEMBLIES (I.E. DOORS, GYPSUM ENCLOSURES,
SPRAYED FIRE PROOFING, ETC.) AT ALL EXISTING AND NEW
LOCATIONS INCLUDING BUT NOT LIMITED TO STRUCTURAL
COLUMNS, BEAMS, AND FLOOR SLABS.
F ALL CONDUIT PIPING IN ELECTRICAL ROOMS TO BE
CONCEALED WITHIN THE WALL CONSTRUCTION.
G WHERE ELECTRICAL, MECHANICAL AND/OR PLUMBING ITEMS,
SUCH AS LIGHTS, DUCTS, PIPING, DOWNSPOUTS, ETC. ARE
SHOWN TO PENETRATE OR CONFLICT WITH ANY BUILDING
FOOTINGS, SLABS, FLOORS, STRUCTURAL FRAMING, WALL
PARTITIONS, CEILINGS, ETC., IT IS REQUIRED THAT AN
APPROPRIATELY SIZED OPENING OR CLEARANCE BE
FURNISHED. THE CONTRACTOR SHALL COORDINATE THE
INSTALLATION OF ALL ITEMS WITH THE CONSTRUCTION
DOCUMENTS PRIOR TO THE INSTALLATION OF STRUCTURAL,
MECHANICAL, PLUMBING AND ELECTRICAL WORK. ANY
CONFLICT OR DISCREPANCY WITHIN THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE CONTRACTING
OFFICER'S ATTENTION FOR CLARIFICATION. ANY WORK
INSTALLED IN CONFLICT WITH THE ARCHITECTURAL
DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT
NO EXPENSE TO THE CONTRACTING OFFICER.
H CONTRACTOR SHALL COORDINATE WITH CONTRACTING
OFFICER CONCERNING THE PROPER REMOVAL OF ALL DEBRIS
ASSOCIATED WITH THE WORK.
I THE GENERAL CONTRACTOR SHALL MAINTAIN A CLEAN AND
ORDERLY JOBSITE, FREE OF DEBRIS AND LITTER. UPON
COMPLETION, ALL CONTRACTORS SHALL REMOVE THEIR
TRASH AND DEBRIS FROM THE PREMISES. ALL AREAS SHALL
BE BROOM CLEANED.
J ALL DIMENSIONS ARE TO FACE OF CURB, FACE OF CONCRETE
OR MASONRY, FACE OF FINISH, OR CENTERLINE OF GRID
UNLESS NOTED OTHERWISE.
K CONTRACTOR SHALL FIELD MEASURE AS REQUIRED FOR ALL
WORK RELATED TO GLAZING AND MILLWORK PRIOR TO
FABRICATION.
L CONTRACTOR SHALL ENSURE THAT ALL ENTRANCES AND
EXITS FROM THIS TENANT IMPROVEMENT SPACE MEETS
ACCESSIBLE MEANS OF EGRESS REQUIREMENTS
M CONTRACTOR SHALL COORDINATE WALL INSTALLATION WITH
EXISTING FIRE SUPPRESSION SPRINKLER HEAD LOCATION.
CONTRACTOR SHALL MAINTAIN 4" MIN. CLEARANCE FROM
CENTER OF SPRINKLER HEAD TO FACE OF WALL.
04 8 16268
SCALE: 1/8"=1'-0"
1/4" = 1'-0"A-101
B1 PARTIAL SECOND FLOOR PLAN
KEYNOTE LEGEND
01 NEW EQUIPMENT, SEE EQUIPMENT PLAN
02 PATCH EXISTING WALL TO THE SAME LEVEL OF FINISH AS
ADJACENT WALL CONSTRUCTION. MAINTAIN CONTINUITY OF
FIRE RATING.
04 NEW DOOR, FRAME AND HARDWARE
05 MODIFY FRAMES FOR NEW HW, MAINTAIN PARTITION RATING
AT OPENING
06 PRINTER BY OTHERS, PROVIDE EMERGENCY POWER
07 VERIFY PARTITION IS FULL HEIGHT [ROOF DECK TO FLOOR
SLAB] & STC 45 RATING. MODIFY AS NECESSARY.
08 VIDEO DISPLAY MONITORS, OFCI
11 PATCH AND REPAIR EXISTING WALLS AND CEILINGS IN
CORRIDOR, ELECTRICAL, MECHANICAL AND COMMS ROOM
AS NECESSARY. COORDINATE WITH ENGINEERING
DRAWINGS.
13 STATIC DISSIPATIVE CARPET TILE, MATCH EXISTING, PLACE
TRANSITION BELOW DOOR IN CLOSED POSITION
15 ALIGN EQUIPMENT W/ RAISED FLOOR TILES WHERE
POSSIBLE. CONTRACTOR SHALL FIELD VERIFY FLOOR TILE
LOCATION AND FULLY COORDINATE W/ EQUIPMENT FOR
LOCATION. MINIMIZE CUTTING OF TILES. USE MFR'S DETAILS
FOR BRIDGING, TRIM, ETC AS NECESSARY TO CONFORM W/
PLAN
PLAN NORTH
RCP LEGEND
EXIT SIGN
2 X 2 ACOUSTIC CEILING TILE SYSTEM
(.90 NRC)
2 X 2 LED RECESSED LIGHTING
? KEYNOTE
HVAC SUPPLY
HVAC RETURN
B C D E
20 20
20 20
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri s i n d ic a te d
/2
/2
:5
:2
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-102
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
D B
E H
-1
A A
-1
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1/4" = 1'-0"A-102
B1 SECOND FLOOR REFLECTED CEILING PLAN
PLAN NORTH
02 4 8134
SCALE: 1/4"=1'-0"
GENERAL NOTES - CEILING
A CONTRACTOR TO PROTECT EXISTING MECHANICAL UNITS AND
DUCTWORK TO REMAIN DURING EXTENT OF CONSTRUCTION.
COORDINATE WITH ENGINEERING DRAWINGS & SPECIFICATION
MANUAL.
B EXISTING CEILING TO REMAIN, GC TO REPLACE TILES OF CEILING THAT
ARE DAMAGED DURING CONSTRUCTION. MATCH EXISTING TILE.
C SPRINKLERS, EXIT SIGNS, AND SPEAKERS SHALL BE LOCATED IN
ALIGNMENT W/ LIGHT FIXTURES AND OTHER CEILING ELEMENTS.
WHERE THERE ARE NO LIGHT FIXTURES, AND/OR SPRINKLERS SHALL
BE CENTERED IN CEILING TILE. SPRINKLERS SHALL BE FULLY
CONCEALED WITH WHITE CAPS. CONTRACTOR TO COORDINATE.
D GC TO COORDINATE THE ALIGNMENT OF THE CEILING GRID AND
PARTITIONS.
E ALL CEILINGS TO MATCH EXISTING, UNO. ALL CEILING LAYOUTS TO
START AT CENTER OF ROOM, UNO.
F CEILING HEIGHTS TO BE COORDINATED WITH MECHANICAL UNITS, FIRE
SPRINKLERS, STRUCTURAL BEAMS, AND LIGHT FIXTURES AGAINST
EXISTING CONDITIONS. VERIFY THAT DIMENSIONS ARE CONSISTENT
WITH REQUIREMENTS INDICATED IN THE DOCUMENTS. REFER ANY
DIMENSIONAL INCONSISTENCIES TO CONTRACTING OFFICER FOR
RESOLUTION PRIOR TO THE START OF PARTITION CONSTRUCTION.
G LOCATE RECESSED DOWN LIGHTS, WALL WASHERS, SMOKE
DETECTORS, EXIT SIGNS, SPEAKERS, FIRE SPRINKLERS, ETC. IN
CENTER OF 24" X 24" CEILING TILES OR IN CENTER OF 24"X24" PORTION
OF 24"X48" CEILING TILES, UNO
H LOCATIONS OF CEILING DEVICES, SUCH AS AIR DIFFUSERS, GRILLES,
LIGHT FIXTURES, ETC., AS SHOWN ON ARCHITECTURAL REFLECTED
CEILING PLAN SHALL GOVERN. NOTIFY THE CONTRACTING OFFICER
OF ANY DISCREPANCIES FOR CLARIFICATIONS.
I FIELD VERIFY ALL CLEARANCES OF DUCTS, PIPES, SPRINKLERS, PLAN.
WHERE DISCREPANCIES IN LOCATION OCCUR, NOTIFY THE
CONTRACTING OFFICER OF ANY CONFLICTS PRIOR TO INSTALLATION
OF LIGHTS, ETC.
J GC TO COORDINATE SECURITY ITEMS WITH CONTRACTING OFFICER.
K NOTIFY CONTRACTING OFFICER OF ANY DISCREPANCIES BETWEEN
ARCHITECTURE AND ENGINEERING DRAWINGS AND OBTAIN
CLARIFICATION BEFORE PROCEEDING WITH WORK IN QUESTION.
L NO COMBUSTIBLE MATERIALS SHALL BE USED IN THE PLENUM SPACE,
INCLUDING ALUMINUM FLEX, ALUMINUM CONDUIT, AND POT METAL
CONNECTORS.
M ALL JUNCTION BOXES AND MECHANICAL EQUIPMENT REQUIRING
ACCESS FOR SERVICE SHALL BE LOCATED OVER ACOUSTICAL
CEILINGS. NO ACCESS HATCHES SHALL BE INSTALLED IN GYPSUM
BOARD CEILINGS WITHOUT PRIOR APPROVAL BY CONTRACTING
OFFICER. (NO EXCEPTION)
N HATCHED AREAS INDICATE AREA/ITEMS NOT IN SCOPE OF WORK.
COORDINATE WITH ENGINEERING DRAWINGS FOR FULL EXTENT OF
SCOPE.
O FOR FURTHER INFORMATION ON HVAC DEVICES, SEE HVAC DRAWING
P FOR SPECIFICATIONS OF BUILDING STANDARD LIGHT FIXTURES,
SWITCHES, EXIT SIGNS SEE ELECTRICAL ENGINEERING DRAWINGS.
Q FOR FURTHER INFORMATION ON ELECTRICAL LIGHTING FIXTURES, SEE
ELECTRICAL DRAWINGS
R CONDUIT ABOVE CEILING MUST BE A MINIMUM OF 12" ABOVE THE
CEILING GRID
KEYNOTE LEGEND
20 WINDOW HEADER MOUNTED DUAL PARTIAL AND BLACKOUT SHADES,
SEE C4/A-501
21 WALL MOUNTED SINGLE PRIVACY SHADES, SEE C3/A-501
23 PATCH AND REPAIR EXISTING WALLS AND CEILINGS IN CORRIDOR,
ELECTRICAL, MECHANICAL AND COMMS ROOM AS NECESSARY.
COORDINATE WITH ENGINEERING DRAWINGS.
24 MODIFY CEILING AS NECESSARY FOR NEW PARTITION WALLS
TS
B C D E
101 102 103 104 105
112113114116117
M
IN
MIN
3'-0"
/8
4'-6 1/4"
4'-5"
4'-3 7/16"4'-6 1/4"5'-6 3/16"
4'-5 1/2"
ALIGN
ALIGN
ALIGN
3'-11 11/16"
ALIGN
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/4
/2
/2
:5
:2
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-103
E Q
U
IP
M E
N T
P L A
N
D B
E H
-1
A I
A -1
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1/4" = 1'-0"A-103
C1 SECOND FLOOR EQUIPMENT PLAN
02 4 8134
SCALE: 1/4"=1'-0"
EQUIPMENT SCHEDULE
EQUIP
NO. EQUIPMENT REMARKS FURNISH INSTALL
15 10-TONS CRAC UNIT UNIT MOUNTED ON STEEL SUPPORT. CONTRACTOR CONTRACTOR
16 10-TONS CRAC UNIT UNIT MOUNTED ON STEEL SUPPORT. CONTRACTOR CONTRACTOR
17 SINGLE STATIC UNINTERRUPTED POWER SUPPLY UNIT BATTERY PACK COMPONENT MOUNTED ON STEEL SUPPORT. CONTRACTOR CONTRACTOR
20 STARS USER ROOM CONSOLE-1 OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.
CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.
VENDOR VENDOR
21 STARS USER ROOM CONSOLE-2 OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.
CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.
VENDOR VENDOR
22 DRC CONTROL ROOM CONSOLE OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.
CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.
VENDOR VENDOR
23 DISPLAY VIDEO WALL OWNER'S VENDOR SHALL PROVIDE DIMENSIONS TO CONTRACTOR.
CONTRACTOR TO PROVIDE ROUGH-INS AND CUTOUTS.
VENDOR VENDOR
101 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
102 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
103 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
104 MOVABLE RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
105 MOVABLE RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
106 EIS RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
107 EIS RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
108 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
109 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
110 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
111 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
112 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
113 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
114 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
116 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
117 RACK MOUNT EQUIPMENT CABINET OWNER CONTRACTOR
A-501
A1
SOUND BATT. SINGLE
BATT WIDTH.
A-501
C3 A
OFFICE
205A
OFFICE
STARS USERS
ROOM
DATA REDUCTION
CONTROL
CENTER
204A
DATA REDUCTION
CENTER
A-501
A3
C
A-501
A3
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/4
/2
/2
:5
:3
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-201
B U
IL
D
IN
G
S E
C T
IO
N
S
D B
E H
-1
A A
-2
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1/4" = 1'-0"A-201
B1 SECTION 3
1/4" = 1'-0"A-201
D1 SECTION 4
1/4" = 1'-0"A-201
A3 SECTION 2
1/4" = 1'-0"A-201
A1 SECTION 1
2'-0" TYP.
B
DATA REDUCTION
CENTER
2'-0" TYP.
DATA REDUCTION
CENTER
2'-0" TYP.
AWP-1:
AWP-2:
AWP-3:
ACOUSTICAL WALL PANEL LEGEND
COLOR TO BE SELECTED AND APPROVED BY CONTRACTING
OFFICER & AEROSPACE FROM MFR'S FULL RANGE OF
COLORS)
NOTE: COORDINATE AWP WALL MOUNTED DEVISES.
STARS USERS
ROOM
STARS USERS
ROOM
204 6
C
"4
/4
/4
WALL MOUNTED
MONITOR
A
C
6'-0"
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/4
/2
/2
:5
:3
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-202
P A
R T
IA
L E
L E
V A
T
IO
N S
D B
E H
-1
A -2
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1/4" = 1'-0"A-202
A5 EAST WALL - DRC AWP ELEVATION
1/4" = 1'-0"A-202
B1 WEST WALL - DRC AWP ELEVATION
1/4" = 1'-0"A-202
A1 NORTH WALL - DRC AWP ELEVATION
1/4" = 1'-0"A-202
A3 SOUTH WALL - DRC AWP ELEVATION
1/4" = 1'-0"A-202
B5 SOUTH WALL - SUR
1/4" = 1'-0"A-202
B3 NORTH WALL - SUR
1/4" = 1'-0"A-202
C2 EAST WALL - SUR
1/4" = 1'-0"A-202
C1 WEST WALL - SUR
1/4" = 1'-0"A-202
C3 SOUTH WALL - DRCC
1/4" = 1'-0"A-202
C4 WEST WALL - DRCC
1/4" = 1'-0"A-202
B2 Elevation 2 - a
MIN 16 GA, 6" MTL STUD,
SPACE 16" OC
FASTENER
MIN 16 GA, 6"
UNPUNCHED MTL STUD,
EXTEND FULL LENGTH
OF SIGN OR
ARCHITECTURAL
ELEMENT. PLACE STUD
AT EA END.
COORDINATE LOCATION
OF BACKING W/
EQUIPMENT PLAN
SHADE HOUSING
ROLLER TUBE SHADE
ASSEMBLY ( MANUAL)
ROLLER SHADE SYSTEM
EXISTING WALL
SILL BEYOND
EXISTING
STOREFRONT
ACOUSTIC JOINT
FILLER
DOUBLE MTL STUD
AT END OF PARTITION
ANODIZED ALUM
END CAP, MATCH
STOREFRONT
SOUND ATTENUATING
WALL CLOSURE [B.O.D.
MULL IT OVER]
SUSPENDED ACOUSTICAL
CEILING
SUSPENSION CEILING WALL
ANGLE
WALL AS SCHEDULED
PATCH AND REPAIR EXISTING
RAISED FLOOR SYSTEM AS
NECESSARY, PROVIDE NEW
FLOOR COVERING
STRUCTURAL FLOOR
MONITOR BACKING WHERE
REQUIRED
FASTEN CONT CHANNEL
TO CONC FLOOR OVER
(2) CONT BEADS OF
SEALANT
ACOUSTIC SEALANT
CONT DEFLECTION TRACK
FASTENED TO STRUCTURE
ABOVE
FASTEN GYP BOARD TO
LOWER DEEP LEG TRACK
ONLY TO ALLOW FOR SLIP
CONNECTION
A-501
C2
A-501
C2
BASE AS SCHEDULED
ALUMINUM
STOREFRONT SYSTEM
BATT INSULATION
WALL AS SCHEDULED
BLOCKING
ROLLER TUBE AND SHADE
ASSEMBLY (MANUAL)
METAL THRESHOLD W/
GASKET ON UNDERSIDE
SEALANT BED
FINISH AS SCHEDULED ON
EXISTING RAISED FLOOR
SYSTEM
FIRE CAULK [ACOUSTIC
SEALANT FOR INTERIOR
SOUND PARTITIONS]
GYP WALL BOARD ON MTL
STUD FRAMING. SEE PLAN.
BATT INSULATION
DOOR AS SCHEDULED
/2
M
A X
DOOR FRAME BEYOND
EXISTING SLAB
FIRE CAULK [ACOUSTIC
SEALANT FOR INTERIOR
SOUND PARTITIONS]
METAL THRESHOLD W/
GASKET IN SEALANT BED.
ACOUSTIC SEALANT
FINISH AS SCHEDULED ON
EXISTING RAISED FLOOR
SYSTEM
ACOUSTIC SEALANT
WALL AS SCHEDULED
BATT INSULATION
DOOR AS SCHEDULED
DOOR FRAME BEYOND
EXISTING SLAB
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri s i n d ic a te d
/2
/2
:5
:4
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-501
D E
T A
IL
S
D B
E H
-1
A -5
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1 1/2" = 1'-0"A-501
C2 BACKING DETAIL
1 1/2" = 1'-0"A-501
C4 DOUBLE ROLL-UP SHADES
3" = 1'-0"A-501
A2
WALL TO MULLION
CONNECTION DTL
1 1/2" = 1'-0"A-501
A1 WALL SECTION
1 1/2" = 1'-0"A-501
C3 HEADER DETAIL
3" = 1'-0"A-501
A3 SILL DETAIL - RATED / ACOUSTIC PARTITION
3" = 1'-0"A-501
A5 TYPICAL SILL DETAIL
TYPE A TYPE B
AS SCHEDULED
A S
S C
H E
D U
L E
D
AS SCHEDULED
A S
S C
H E
D U
L E
D
5"
" G1
TYPE C
AS SCHEDULED
A S
S C
H E
D U
L E
D
SOLID WD DOOR SOLID WD DOOR SOLID WD DOOR
F1
2" 2"
AS SCHEDULED
A S
S C
H E
D U
L E
D
HM FRAME
DOOR AS SCHEDULED,
SEE SCHEDULE FOR
ASSEMBLY RATING
/8
GYP BOARD EA SIDE , SEE LIFE
SAFETY PLAN TO LOCATE
PARTITONS WITH RATED
CONDITIONS
DOUBLE MTL STUDS
ADJACENT
WALL
WHERE IT
OCCURS
NOTE: HEAD
IS SIMILAR
/1
/8
/1
/4
2"
A
12'-2" 16'-2"
7'-8"
B C
2" EQ 2" EQ 2"
2" 2" 2" 2"EQ EQ EQ
2" 2" 2" 2" 2"
EQ EQ EQ EQ
G1 G1 G1G1G1 G1 G1 G1 G1
4 7/8"
7/16" 4 7/8"
7/16"
3 5/8"
5 3/4"
WALL AS SCHEDULED
DOOR AS SCHEDULED
HM FRAME
INSULATION
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri s i n d ic a te d
/2
/2
:5
:4
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-601
O P
E N
IN
G
S C
H E
D U
L E
S A
N D
D E
T A
IL
S
D B
E H
-1
A A
-6
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
DOOR SCHEDULE
MARK
ROOM
NUMBER ROOM NAME
DOOR FRAME
FINISH HARDWARE NOTESDOOR SIZE THICK MAT'L FINISH RATING TYPE GLAZ MAT'L TYPE GLAZ
203 203 DATA REDUCTION CENTER PR 2'-8" x 8'-0" 1 3/4" WD PT 20 C - HM F1 PT 01 3
204 204 STARS USERS ROOM 3'-0" x 7'-0" 1 3/4" WD PT 20 A - HM F1 PT 02 1,3
204A 204 STARS USERS ROOM 3'-0" x 7'-0" 1 3/4" WD PT -- A - HM F1 PT 04 4
204B 204A DATA REDUCTION
CONTROL CENTER
3'-0" x 7'-0" 1 3/4" WD PT -- A - HM F1 PT 06 3
205A 205A OFFICE 3'-0" x 7'-0" 1 3/4" WD PT B G1 HM F1 PT 05 3
205B 205B OFFICE 3'-0" x 7'-0" 1 3/4" WD PT B G1 HM F1 PT 05 3
205C 205C OFFICE 3'-0" x 7'-0" 1 3/4" WD PT B G1 HM F1 PT 05 3
E205 205 OFFICE 3'-0" x 7'-0" 1 3/4" WD PT 20 A - HM F1 PT 03 2,3
GENERAL NOTES - DOORS
A CONTRACTOR TO FIELD VERIFY ALL OPENING DIMENSIONS PRIOR
TO WORK
B VERIFY THAT ALL DOORS AND DOOR HARDWARE MEET THE
REQUIREMENTS OF THE LOCAL, STATE AND FEDERAL CODE.
NOTIFY THE CONTRACTING OFFICER IMMEDIATELY IN CASE OF
DISCREPANCY
C REFER TO SPECIFICATIONS FOR DOOR AND FRAME MATERIALS
AND REQUIREMENTS, AND PLANS FOR ADDITIONAL DOOR
INFORMATION.
D EXIT DOORS:
ALL EXIT DOORS SHALL BE OPENABLE FROM INSIDE WITHOUT THE
USE OF A KEY OR ANY SPECIAL KNOWLEDGE. ALL DOOR SWINGS
SERVING AN OCCUPANT LOAD OF 50 OR GREATER SHALL SWING IN
THE DIRECTION OF EXIT.
E ALL GLAZING SHALL BE SAFETY IMPACT GLASS TO COMPLY WITH
FBC SECTION 2406.2, UNO
F INSTALLATION OF ALL DOORS AND HARDWARE SHALL MEET MIN.
“ADA” AND "ADAAG" REQUIREMENTS. IF ANY CONFLICTS ARISE,
THE ITEM MUST BE BROUGHT TO THE ARCHITECT’S ATTENTION
PRIOR TO CONSTRUCTION.
G MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED THE
FOLLOWING:
a. INTERIOR DOORS - 5 POUNDS
b. EXTERIOR DOORS - 5 POUNDS
c. AUTHORITY HAVING JURISDICTION MAY ALLOW INCREASE
OPENINGS FORCE, NOT TO EXCEED 15 LB
H MOUNT ALL HARDWARE PER LATEST EDITION OF THE GOVERNING
CODES
I ALL DOORS ARE TO BE OPENABLE FROM INSIDE WITHOUT THE
USE OF A KEY OR SPECIAL KNOWLEDGE. "IN LIEU OF THE ABOVE
REQUIREMENTS, IN GROUP B OCCUPANCIES YOU MAY NOTE
"PROVIDE A SIGN ON OR NEAR THE EXITS DOORS READING "THIS
DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" THIS
SIGNAGE IS ONLY ALLOWED AT THE MAIN EXIT
J CONTRACTOR IS RESPONSIBLE TO COORDINATE & VERIFY ALL
DOOR FRAME THROAT THICKNESS FOR EACH LOCATION.
K LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED
SHALL BE OPENABLE WITH A SINGLE EFFORT WITHOUT REQUIRING
THE ABILITY TO GRASP THE HARDWARE (LEVER OR PUSH TYPE)
MOUNTED 30" TO 44" ABOVE THE FLOOR, VERIFY IF EXISTING.
L ALL HARDWARE SHALL BE UNLOCKED IN THE DIRECTION OF
EGRESS, REGARDLESS OF OTHER LOCK FUNCTIONS.
M ALL FIRE-RATED DOORS SHALL BE SMOKE-GASKETED, POSITIVE
LATCHING, AND SELF-CLOSING
N DOOR AND FRAME ASSEMBLIES OF 1 HOUR EXIT CORRIDORS IF
REQUIRED SHALL BE UL LISTED 20 MINUTES AND SHALL HAVE A
CLOSER AND APPROVED GASKET MATERIAL SO INSTALLED TO
PROVIDE A SEAL WHERE THE DOOR MEETS THE STOP ON BOTH
SIDES AND THE TOP.
P "LABEL" SHALL MEAN 'ASSEMBLY'
Q CONTRACTOR TO INSTALL NEW LEVER HARDWARE ON ALL
EXISTING DOORS. PATCH AND REPAIR AS REQ.
R ALL GLAZING WITHIN A 24" ARC OF EITHER EDGE OF A DOOR AND
WITHIN 60" OF THE FLOOR SHALL BE TEMPERED.
S THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE
DOOR SWINGS SHALL EXTEND 24" PAST THE STRIKE EDGE OF THE
DOOR FOR EXTERIOR DOORS AND 18" PAST THE STRIKE EDGE
FOR INTERIOR DOORS
T PROVIDE A MINIMUM OF 60" LEVEL LANDING ON THE SWING SIDE
OF THE DOOR AND 44" ON THE OPPOSITE SIDE
U ALL INTERIOR DOOR FRAMES SHALL BE FACTORY FINISHED
V REFER TO FINISH SCHEDULE FOR ALL FINISH MATERIALS AND
FINISH LOCATIONS
W VERIFY ALL KEYING WITH THE AEROSPACE CORPORATION PRIOR
TO INSTALLATION
X VERIFY ALL NECESSARY DOOR AND WALL SIGNAGE WITH THE
AEROSPACE CORPORATION PRIOR TO INSTALLATION
DOOR NOTES
1. IF POSSIBLE REVISE SWING OF EXISTING DOOR AND RE-USE EXISTING HW.
MODIFY FRAME AS REQUIRED. PROVIDE 180 DEGREE DOOR SWING.
2. EXISTING DOOR, MODIFY DOOR AS REQUIRED
3. SEE A3/A-501 FOR RATED/ACOUSTIC SILL DETAIL.
4. SEE A5/A-501 FOR TYPICAL SILL DETAIL.
1/4" = 1'-0"A-601
C1 DOOR TYPE
GLAZING TYPES
G1. 1/4" TEMPERED GLAZING
1/4" = 1'-0"A-601
C2 FRAME TYPE
3" = 1'-0"A-601
C3 DOOR JAMB
1/4" = 1'-0"A-601
B1 WINDOW TYPES
3" = 1'-0"A-601
C4 DOOR HEAD
B C D E
STARS USERS
ROOM
OFFICE
OFFICE
205A
OFFICE
205B
OFFICE
205C
DATA REDUCTION
CENTER
DATA REDUCTION
CONTROL
CENTER
204A
PT-4
PT-1
PT-5
PT-3
PT-5
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
SHEET OF
T H
S P
A C
E W
IN
G
C C
A F
S F
L
C O
N T
R A
C T
N
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
D E
L
IV
E R
Y O
R D
E R
N O
C
K D
B Y x
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
T R
A C
E S
T E
C H
N
IC
A L R
A N
G E
A R
C H
IT
E
C T
U R
A L E
N G
IN
E
E R
IN
G
S E
R V
IC
E
S
A A rh o d e s b ri
/4
/2
/2
:5
:4
P
M
E R
S T
A R
S R
E L
O C
A T
IO
N
A-701
F
IN
IS
H
P L A
N
D B
E H
-1
A -7
F A
-1
D
-0
A u g u s t
F A
F A
F A
-1 D
-0
D e s ig n e r
A u th o r
A p p ro v e r
C h e c k e r
1/4" = 1'-0"A-701
B1 SECOND FLOOR FINISH PLAN
GENERAL NOTES-FINISHES
A REFER TO REFLECTED CEILING PLAN FOR CEILING FINISHES.
B ALL FINISHES SHALL BE COORDINATED AND APPROVED BY THE
CONTRACTING OFFICER PRIOR TO INSTALLATION AND
PROCUREMENT
C ALL FINISHES SHALL BE APPLIED IN STRICT ACCORDANCE TO
MANUFACTURER'S SPECIFICATIONS
D ALL PAINT FINISH OF METAL PARTS OF DOORS, HANDRAILS,
PERIMETER ENCLOSURES, ETC SHALL BE SEMIGLOSS, UNLESS
OTH…
This is the start of the file's text. The full file is on GovTribe.