Exhibit E - Electrical O-M Manual.pdf

PDF 3 MB Posted

Attached to
Design-Build Miscellaneous Repairs Federal contract opportunity
Solicitation number
12505B21R0002
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Midwest Area

View the file

Other files for this federal contract opportunity

Other files attached to Design-Build Miscellaneous Repairs, newest first.
File Type Posted
Site Visit Sign In Sheets.pdf PDF
SF-30 Amendment 01.pdf PDF
ARS Facilities Design Standards.pdf PDF
Exhibit A - Drawings for Recent Work.pdf PDF
Exhibit B - Specifications for Recent Work.pdf PDF
Exhibit F - Test and Balance Report.pdf PDF
ARS-371.pdf PDF
SF-1442 with Clauses and Provisions.pdf PDF
Statement of Work.pdf PDF
Exhibit C - Make Up Air Unit O-M Manual Part 1.pdf PDF
Exhibit D - Make Up Air Unit O-M Manual Part 2.pdf PDF
Wage Determination.pdf PDF
ARS-372.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Siemens Submittal Package

USDA LBRU ANIMAL HOLDING AREA

10/19/2018Date :

usa.siemens.com/COMPAS

To: ADVANCED TECHNOLOGIES IN ELECTRICAL AND

COMMUNICATIONS INC (ATEC INC)

419 RANSDELL RD

LEBANON, IN, 46052

US

Job Name:

Quote Name:

ATEC

USDA LBRU ANIMAL HOLDING AREA

Quote Number:

Distributor:

nagldx00c_01101700_25_00_M00

KIRBY RISK CORP

ADVANCED TECHNOLOGIES IN ELECTRICAL

AND COMMUNICATIONS INC (ATEC INC)

Contractor:

Drawings are for: Approval Record

Please find enclosed 1 Copy of the below listed materials for the above referenced job.

Contents:

Molded Case Circuit Breakers IEC/OEM Control Components Panelboards

Upon the return of 1 Copy of “Approved “ or “No Exceptions Noted” drawings with release, it will be considered fact that the material as shown meets the requirements of the plans and specifications. For drawings returned indicating “Approved as Noted” or “Exceptions as Noted”, the cost of any additional equipment not included in the original quotation will be reflected in the total invoice price. Any changes other than those shown on these returned drawings will not be considered the responsibility of Siemens. It must be noted that these drawings and descriptive literature incorporate Siemens’ interpretation of the plans and specifications and are subject to corrections of errors. The above material is on “Hold for Release” status and will not be released until the receipt of signed submittals having one of the above notations with formal release. These drawings along with release should be returned as soon as possible so as not to cause any delays in shipping and/or escalation that might be incurred due to these delays.

Approval Drawings:

These drawings reflect the products manufactured by Siemens for this job.

Record Drawings:

10/19/2018Date:TRANSMITTAL LETTER

Bill of Material

To:

419 RANSDELL RD

LEBANON, IN 46052

USA

From:

4025 E. Cotton Center Suite 200

USA

Phoenix, AZ 85040

ADVANCED TECHNOLOGIES IN

ELECTRICAL AND COMMUNICATIONS INC

(ATEC INC)

Siemens Industry, Inc.

Job Name:

Quote Number:

ATEC

USDA LBRU ANIMAL HOLDING AREA

nagldx00c_01101700_25_00_M00

Quote Name:

Distributor: ADVANCED TECHNOLOGIES IN ELECTRICAL AND COMMUNICATIONS INC (ATEC INC)Contractor: ADVANCED TECHNOLOGIES IN ELECTRICAL AND COMMUNICATIONS INC (ATEC INC)Consultant:

DescriptionQuantityLine No.

20000 1 A3--PANELBOARD P1

1 SECTION

P1A18ML125CTST, System Voltage: 120/240 1Ø 3W GND Neutral AC, IR @ 22,000 AIC, Top Feed, Surface Mount, Bus Rating: 250A, Bus Material:

Copper, Plating: Tin, NEMA 1 INDOOR.

1 INTERIOR W/ 125A MAIN LUG-

(1)#6-350Kcmil1 - Subfeed/Feedthru Provision1 - 20" Wide NEMA 1 Indoor Enclosure1 - Card Holder-Std Plastic Sleeve1 - Certification - UL1 - Std Al/Cu Gnd Connector1 -

3 20A /2P-BLH-

Catalog #: B220H1 -

12 20A /1P-BLH-

Catalog #: B120H1 -

Enclosure, Catalog Number B32 Front, Catalog Number S32B

10 2 Standard Product--BREAKER 70A 2P 120/240V 22K BLH Catalog No.: B270H

11 2 UH-1 & UH-2--STARTER,MANUAL,TOGGLE SWITCH W/P.LIGHT

Catalog No.: SMFFG2P

12 2 UH-1 & UH-2--CLASS SMF HEATER ELEMENT,4.08-4.32 AMP

Catalog No.: SMFH36

13 4 EF-1A, EF-1B, EF-2 & P-1--STARTER,MANUAL,TOGGLE SWITCH W/P.LIGHT

Catalog No.: SMFFG1P

Bill of Material Date: 10/19/2018

1nagldx00c_01101700_25_00_M00

14 1 P-1--CLASS SMF HEATER ELEMENT,8.99-9.67 AMP

Catalog No.: SMFH45

15 3 EF-1A, EF-1B & EF-2--CLASS SMF HEATER ELEMENT,0.97-1.04 AMP

Catalog No.: SMFH19

Bill of Material Date: 10/19/2018

2nagldx00c_01101700_25_00_M00

Panelboards

A3

KIRBY RISK CORP

nagldx00c nagldx00c_01101700_25_00_M00-20000-1

1 2

ATEC

ADVANCED TECHNOLOGIES IN ELECTRICAL AND COMMUNICATIONS INC (ATEC INC)

A3

KIRBY RISK CORP

nagldx00c nagldx00c_01101700_25_00_M00-20000-1

1 2

ATEC

ADVANCED TECHNOLOGIES IN ELECTRICAL AND COMMUNICATIONS INC (ATEC INC)

A3

PANELBOARD NOTES

SECTION :1 OF 1

PANEL TYPE :P1

CATALOG NUMBER :P1A18ML125CTST

ENCLOSURE :1 Indoor SYSTEM VOLTAGE :120/240 1Ø 3W GND Neutral AC

IR RATING :22 K AIC

MAIN BUS :125 A

BUS MATERIAL :Tin Plated Copper FEED :Top MOUNTING :Surface SE LABEL :No SERIES RATED :No

CONDUIT AREA :N/A

*INDICATES POSITIONING NUMBERS TO HELP WITH

THE MANUAL PLACEMENT OF BREAKERS ON THE

MECHANICAL VIEW

PANELBOARD COMPONENTS

Main :

1 - 125A MAIN LUG

1-(1)#6-350Kcmil

Branches :

3 - 20A /2P-BLH

12 - 20A /1P-BLH

Options :

1-Subfeed/Feedthru Provision 1-Card Holder-Std Plastic Sleeve 1-NP Location - Trim 1-Certification - UL 1-Std Al/Cu Gnd Connector

9.0

K

IT

.0BLH 9 20A/1P

BLH1220A/1P

BLH 15 20A/1P

BLH1820A/1P

BLH

20A/2P

BLH620A/1P

BLH1020A/1P

BLH 13 20A/1P

BLH1620A/1P

BLH

20A/2P

BLH820A/1P

BLH 11 20A/1P

BLH1420A/1P

BLH 17 20A/1P

BLH

20A/2P

SUB FEED

PROVISION

125 A

MLO

20.05.75 Deep

DESIGNATION(S): PANELBOARD NOTES

NO. REVISIONS DATEDRAWN BY

1 0 10-17-2018nagldx00c

PANELBOARD COMPONENTS

JOB

P.O.

TIE

S.O.

CUST.

ENG. LOC.BY

DATE

APP.

APP.

MFG. LOC.

DWG. FILE

DESIGNATION

DWG. NO.

REV.

SHEETNorcross, Georgia

Siemens Industry, Inc.

10-17-2018

1OF

CONSLTCONTR

JOB

P.O.

TIE

S.O.

CUST.

ENG. LOC.BY

DATE

APP.

APP.

MFG. LOC.

DWG. FILE

DESIGNATION

DWG. NO.

REV.

SHEETNorcross, Georgia

Siemens Industry, Inc.

10-17-2018

1OF

CONSLTCONTR

KIRBY RISK CORP

nagldx00c nagldx00c_01101700_25_00_M00-20000-2

2 2

ATEC

ADVANCED TECHNOLOGIES IN ELECTRICAL AND COMMUNICATIONS INC (ATEC INC)

A3

KIRBY RISK CORP

nagldx00c nagldx00c_01101700_25_00_M00-20000-2

2 2

ATEC

ADVANCED TECHNOLOGIES IN ELECTRICAL AND COMMUNICATIONS INC (ATEC INC)

A3

ABBREVIATIONS

'MLO' MAIN LUGS ONLY

PANELBOARD NOTES

SECTION :1 OF 1

PANEL TYPE :P1

CATALOG NUMBER :P1A18ML125CTST

ENCLOSURE :1 Indoor SYSTEM VOLTAGE :120/240 1Ø 3W GND Neutral AC

IR RATING :22 K AIC

MAIN BUS :125 A

BUS MATERIAL :Tin Plated Copper FEED :Top MOUNTING :Surface SE LABEL :No SERIES RATED :No

CONDUIT AREA :N/A

*INDICATES POSITIONING NUMBERS TO HELP WITH

THE MANUAL PLACEMENT OF BREAKERS ON THE

MECHANICAL VIEW

A C

A C

A C

A C

A

9BLH 20A/1P

12 BLH 20A/1P

15BLH 20A/1P

18 BLH 20A/1P

BLH 20A/2P

6 BLH 20A/1P

10 BLH 20A/1P

13BLH 20A/1P

16 BLH 20A/1P

BLH 20A/2P

8 BLH 20A/1P

11BLH 20A/1P

14 BLH 20A/1P

17BLH 20A/1P

BLH 20A/2P

(1)#6-350KCMIL/PH AND N

125A

ABBREVIATIONS

'MLO' MAIN LUGS ONLY

PANELBOARD NOTES

JOB

P.O.

TIE

S.O.

CUST.

ENG. LOC.BY

DATE

APP.

APP.

MFG. LOC.

DWG. FILE

DESIGNATION

DWG. NO.

REV.

SHEETNorcross, Georgia

Siemens Industry, Inc.

10-17-2018

1OF

CONSLTCONTR

JOB

P.O.

TIE

S.O.

CUST.

ENG. LOC.BY

DATE

APP.

APP.

MFG. LOC.

DWG. FILE

DESIGNATION

DWG. NO.

REV.

SHEETNorcross, Georgia

Siemens Industry, Inc.

10-17-2018

1OF

CONSLTCONTR

usa.siemens.com/panelboards

- 30, 42 and 54 circuits for 400A (FT & NFT), also 66 circuit NFT

- 56”, 62”, 68” and 74” standard Enclosures are used.

• Suitable for use as service entrance given compliance with NEC.

• Bonding provisions are shipped with each panel.

• 240V and 480Y / 277V versions utilize identical boxes & fronts

Enclosure – Standard Type 1 enclosure is 20” wide x 5.75” deep.

Box Height is determined only by the number of circuits and FT or NFT selection, not by main lug or main circuit breaker. See charts P1-3 and P1-5 for box height.

Voltage – 480Y/277 Vac max. (Limited options for 600Y / 347V)

Amperage – 400 amp max.

Short Circuit Rating – 200 KAIC max. symmetrical or equal to the lowest rated device installed unless a series rating is indicated.

Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating.

The three-cycle rating for the P1 panel is limited to 22 KAIC. Note that the main device may be mounted remote from the panel.

Bussing – The P1 panel meets the majority of the markets bussing requirements. The standard bussing is temperature rated aluminum. The rating is per the requirements of UL 67– the standard for panelboards. All aluminum bussing is tin-plated.

Optional bussing for the P1 panel is temperature rated copper.

The copper bus option for this panel is tin-plated.

Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is about 3 lbs. (1.36 kg) per inch (54g per

mm) of box height.

Table P1-1 – Box Material Gauge Width Height (inches) Gauge Steel

20” (250A) 26, 32, 38, 44, 50, 56 #16 (#17 for endwalls)

(400A) 56, 62, 68, 74 #16 (#17 for endwalls)

Table P1-2 – Trim Material Gauge 20” (250A) 26, 32, 38, 44, 50, 56 #14

(400A) 56, 62, 68, 74 #14

Note: Tables in this document are numbered to match tables in Revised P1 S&A guide for consistency.

P1 Panelboards

The P1 Panelboards are available in both Feed-thru (FT) and Non-Feed-thru (NFT) variations. There is a savings of 6” of box height when a NFT version is selected which eliminates the sub-feed space. The Sub-Feed Space is where the Feed-thru Lugs, sub-feed breaker or a Surge Protection Device (SPD) is installed. The interior part number will end with a "T" for FT panels and will end with an "N" for NFT panels.

The P1 Panelboards also have Extended Circuit variations with 54 circuits and 66 circuits available.

Feed-thru (FT) panels are pre-engineered to accept the most common modifications without increasing box height. The enclosure size is determined by the number of circuits as shown in the Main Lug Table P1-5 or the Main Circuit Breaker Table P1-3.

All P1 FT main lug or main breaker panelboards have space built-in to accept either feed-thru lugs equal to the panel rating (or) one subfeed circuit breaker up to 250 amperes (or) a surge suppressor (SPD) without increasing box height. (When ordered with sub-feed space the interior part # will end with a “T”).

Non-Feed-thru (NFT) panels do not have a sub-feed space and cannot accept feed-thru lugs (or) sub-feed Breakers (or) SPD/TVSS devices.

(NFT panel interior part # will end in “N”).

Note the following features, all found in the innovative P1 lighting panelboards:

• Symmetrical 250A FT Interiors – To change from top to bottom-feed (or vice-versa), simply invert the interior. The deadfront labeling is always legible, even on the NFT panels when inverted.

- 400A are not symmetrical, but they are invertable.

• First in the Industry Ratings of 125 through 400A main lug and main breaker. Field convertible from main lug to main breaker and vice versa – with no increase in enclosure height.

• Field adaptability of feed-thru lugs (or) sub-feed circuit breaker without increasing enclosure size. (FT panels only)

• Neutral system is field upgradeable to 200% capacity – another industry first. (also 2/0 neutrals are available as a field install kit)

• Extended circuit panels are now available – up to 66 circuits.

- 18, 30, 42, 54 and 66 circuits for 250A (FT & NFT)

- 26”, 32”, 38”, 44”, 50” and 56” standard Enclosures are used.

Max Ampere rating

Main Breaker Types

Connections suitable for Cu or Al

Max # Poles FT a

Max # Poles

NFT

Dimensions in inches (mm) Unit Space Box Height

B Weight in

Lbs. (kg)

FT

A

NFT

A

100 BLb, BLHb, HBLb, BQDb

#8-#6 AWG Cu or Al #8-6 AWG Cu or #8-4 AWG Al #8-#1 AWG Cu or #6-#1/0 AWG Al

18 – 9 26 (661) 90 (41) 18 30 9 15 32 (813) 105 (48) 30 42 15 21 38 (965) 120 (55) 42 54 21 27 44 (1118) 135 (61) 54 66 27 33 50 (1270) 150 (67) 66 – 33 – 56 (1423) 165 (73)

NGBb, HGBb, LGBb

15-30 amp: #14-#6 Cu or #12-#6 Al 35-125 amp: #6-1/0 Cu #4-2/0 Al

18 – 9 26 (661) 95 (43)

ED4

ED6, HED4

#14-#10 AWG Cu or #12-10 AWG Al

#3-3/0 Cu or #1-2/0 Al #3-3/0 Cu or #1-2/0 Al

18 30 9 15 32 (813) 110 (50) 30 42 15 21 38 (965) 125 (57) 42 54 21 27 44 (1118) 140 (64) 54 66 27 33 50 (1270) 155 (71) 66 – 33 – 56 (1423) 170 (78)

QJ2, QJH2,

QJ2H, QR2,

QRH2, HQR2,

HQR2H

#6 AWG-300 Kcmil (Cu) or #4 AWG-300 Kcmil (Al)

18 – 9 26 (661) 95 (43) 18 30 9 15 32 (813) 110 (50) 30 42 15 21 38 (965) 125 (57)

250 FXD6, FD6,

HFD6, HFXD6

#6 AWG-350 Kcmil (Cu) or #4 AWG-350 Kcmil (Al)

42 54 21 27 44 (1118) 140 (64) 54 66 27 33 50 (1270) 155 (71) 66 – 33 – 56 (1423) 170 (78)

400 JD6, JXD6,

HJD6, HJXD6

3/0-500 Kcmil (Cu) or 4/0-500 Kcmil (Al)

– 30 – 15 56 (1423) 172 (78) 30 42 15 21 62 (1575) 190 (86) 42 54 21 27 68 (1728) 208 (95) 54 66 27 33 74 (1880) 226 (104)

Note: Main breakers use breaker connectors. For sizes, see breaker connector chart. 400A MLO Panels have wire bend space for 600kcmil CU & AL wire when using standard lugs. With optional 750kcmil AL/CU connectors, wire bend space is available for up to 750kcmil AL wire, but is still limited to 600kcmil CU wire.

a

Maximum Ampere rating

Max # Poles

FT

Max # Poles

NFT

Dimensions in inches (mm)

MLO Connectors Suitable for

Unit Space Box Height B"

Weight in Lbs. (kg)

FT

A

NFT

A

(or)

18 – 9 26 (661) 90 (41)

(1) #6 AWG - 350 kcmil (CU or AL)

18 30 9 15 32 (813) 105 (48) 30 42 15 21 38 (965) 120 (55) 42 54 21 27 44 (1118) 135 (61) 54 66 27 33 50 (1270) 150 (67) 66 – 33 – 56 (1423) 165 (73)

– 30 – 15 56 (1423) 120 (55) AL (2) 1/0 - 250 kcmil or

(1) #2 AWG - 600 kcmil CU (2) 1/0 - 4/0 or

(1) #2 AWG - 600 kcmil

30 42 15 21 62 (1575) 135 (61) 42 54 21 27 68 (1728) 150 (68) 54 66 27 33 74 (1880) 165 (75)

Typical Panelboard Wiring Diagrams

Application Type P1 Panelboards

Table P1-3 – Main Breaker Panel Size Selector – P1

400A 66 circuit only available with non-feed thru versions.

b BL, BLH, HBL, BQD, and xGB mount in unit space and count in max. # of poles.

Table P1-5 - Main Lug Panel Size Selector - P1

Application Type P1 Panelboards

Table P1-6 – Branch Circuit Breakers Max.

Amp Rating

Breaker Type

Number of Poles

Max. Interrupting Rating (kA) Available Trip Values

Connections Suitable for Cu or AI120V 120/240V 240V 277V 480/277V

BL

1 10 – – – – 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70

15-20A #14-#10 AWG Cu #12-#10 AWG Al 25-35A #8-#6 AWG Cu #8-#6 AWG Al 40-50A #8-#6 AWG Cu #8-#4 AWG Al 55-70A #8-#4 AWG Cu #8-#2 AWG Al 80-100A #4-#1/0 AWG Cu #2-#1/0 AWG Al

2 – 10 – – – 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100 3 – – 10 – – 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100

BLR 2 – – 10 – – 15, 20, 30, 40, 50, 60, 70, 90, 100

BL, HID

1 10 – – – – 15, 20, 30 2 – 10 – – – 15, 20, 30

BLH

1 – 22 – – – 15, 20, 30, 40, 50, 55, 60, 70 2 – 22 – – – 15, 20, 30, 40, 50, 60, 70, 90, 100 3 – – 22 – – 15, 20, 30, 40, 50, 60, 70, 80, 90, 100

HBL

1 – 65 – – – 15, 20, 30, 40, 50 2 – 65 – – – 15, 20, 30, 40, 50, 60, 70 3 – – 65 – – 15, 20, 30, 40, 50, 60, 70, 80, 90, 100

BLF2

BLFB

1 10 – – – – 15, 20, 30 2 – 10 – – – 15, 20, 30, 40, 50, 60

BLHF2

BLHFB

1 22 – – – – 15, 20, 30 2 – 22 – – – 15, 20, 30, 40, 50, 60

HBLF2 1 65 – – – – 15, 20, 30

BG a 2 10 – – – – 15, 20, 30 3 – 10 – – – 15, 20, 30

BLE

1 10 – – – – 15, 20, 30 2 – 10 – – – 15, 20, 30, 40, 50, 60

BLEH

1 22 – – – – 15, 20, 30 2 – 22 – – – 15, 20, 30, 40, 50, 60

BAF 1 10 – – – – 15, 20

BAFH 1 22 – – – – 15, 20

BQD

1 – 65 – 14 – 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100 15-40A #14-#6 AWG Cu #12-#6 AWG Al 45-100A #8-#1 AWG Cu #6-#1/0 AWG Al

2 – 65 – – 14 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100

3 – – 65 – 14 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100

NGB bc

1 100 – – 25 – 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

15-30A #14-#6 Cu #12-#6 Al 35-125 #6-1/0 Cu #4-2/0 Al

2 – 100 100 – 25 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

3 – 100 100 – 25 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

HGB bc

1 100 – – 35 – 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

2 – 100 100 – 35 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

3 – 100 100 – 35 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

LGB bc

1 100 – – 65 – 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

2 – 100 100 – 65 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c

3 – 100 100 – 65 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 125 c a Two-pole breaker is one phase and neutral. Three-pole is two phases and neutral.

b P1 panel with NGB/HGB/LGB branch devices will not accept BL or BQD frames in the same panel as branch devices.

c The New Revised P1 (18 circuit 250A only) is limited to 100A per connection (200A per pair) when installing Branch Breakers across from one another.

All other configurations allow 125A per connection max. (250A per pair max.)

Note: BL, HBL and BQD breakers are mounted in common mountings in 3” or (6) pole increments.

Application Type P1 Panelboards

400 amp kit is for main—only, not allowed for subfeed breaker.

Table P1-7 – Subfeed Breakers Breaker Type

Number of Poles

Max. Interrupting Rating (kA) Available Trip Values240V 480Y/277V

QJ2 2, 3 10 – 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225

QJH2 2, 3 22 – 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225

QJ2H 2, 3 42 – 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225

QR2 2, 3 10 – 100, 110, 125, 150, 175, 200, 225

QRH2 2, 3 25 – 100, 110, 125, 150, 175, 200, 225

HQR2 2, 3 65 – 100, 110, 125, 150, 175, 200, 225

HQR2H 2, 3 100 – 100, 110, 125, 150, 175, 200, 225

ED4 2, 3 65 18 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 125

ED6 2, 3 65 25 15, 20, 25, 30, 35, 40 50, 60, 70, 80, 90, 100, 110, 125

HED4 2, 3 100 42 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 125

HHED6 2, 3 100 65 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125

FXD6 2, 3 65 35 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250

FD6 2, 3 65 35 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250

HFD6 2, 3 100 65 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250

HFXD6 2, 3 100 65 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250

Answers for industry.

Circuit breakers

Panelboard mounted, non-interchageable trip, molded case circuit breakers Types BL, BLH, HBL,BLF, BLHF, BLE, BLEF, BAF, BAFH, BG 125A Frame

Specifications:

• 120, 120/240, 240Vac max.

• UL Listed, File # E82615

• CSA and NOM Certified

• HACR Rated

• 40C Calibration

• Thermal / Magnetic Trip

• Molded Case Switch, 2 pole 30 - 60 Amperes

• HID Lighting, 1 & 2 pole 15, 20, 30 Amperes

• SWD duty--1 pole

15 - 20 Amperes

Enclosures: Not Applicable

Interruption ratings

Breaker Type No. of Poles Ampere Rating

UL A.I.R. (kA) RMS Symmetrical Amperes

Volts AC (50/60 Hz)

120 120/240 240

BL

1 10 - 70 10 10

2* 15 - 100 10

2 10 - 125 10

3 10 - 100 10

BLH

1 15 - 70 22 22

2 15 - 125 22

3 15 - 100 22

HBL

1 15 - 70 65 65

2 15 - 125 65

3 15 - 100 65

* UL listed for use on 3-phase grounded "B" systems

Ground-Fault Protection Class A - 5mA

Breaker Type No. of Poles Ampere Rating

UL A.I.R. (kA) RMS Symmetrical Amperes

Volts AC (50/60 Hz)

120 120/240 240

BLF

1 15 - 30 10 10 -

2 15 - 60 - 10 -

BLHF

1 15 - 30 22 22 -

2 15 - 60 - 22 -

Ground-Fault Protection 30mA

BLE

1 15 - 30 10 10 -

2 15 - 60 - 10 -

BLEH

1 15 - 30 22 22 -

2 15 - 60 - 22 -

Arc-Fault Circuit Interrupter

(AFCI)

BAF

1 15 - 20 10 10 -

2 15 - 20 - 10 -

BAFH

1 15 - 20 22 22 -

2 15 - 20 - 22 -tararj Text Box

Factory Added Options For all Factory Modifications Consult Siemens for cost adders

Description

External Accessories

Field installable Padlocking Device for 1, 2, and 3 poles Handle Blocking Device

Pressure Wire Connectors Load Side terminal factory installed only non-UL 50C calibration

400 Hz Calibration

415V, 50Hz Calibration

Fungus Proofing Ampere Rating

Cables Per Lug

Wire Range UL listed 5kA max. A.I.R.

non-UL 1 & 2 poles only

External Accessories (Factory Installed only)

15 - 20 1 #14 - #10 AWG Cu.

1 #12 - #10 AWG Al

25 - 35 1 #14 - #6 AWG Cu.

1 #12 - #6 AWG Al.

Shunt Trip Auxiliary Switch 40 - 50 1 #8 - #6 AWG Cu.

1 #8 - #4 AWG Al.

1 0 55 - 70

1 #8 - #4 AWG Cu.

0 1 1 #8 - #2 AWG Al.

(adds 1 pole width to left side of circuit breaker) 80 - 100

1 #4 - #1/0 AWG Cu.

1 #2 - #1/0 AWG Al.

110 - 125 1 #2 - #1/0 AWG Cu.

1 #1/0 - #2/0 AWG Al.

Note: Molded Case Circuit Breakers having a rated ampacity of 125 amperes or less are to be connected with 60 or 75C wire. Exceptions of this rule are outlined in article 110-12 C of the National Electrical Code.

Switching Neutrals

Breaker Type No. of Poles Ampere Rating

UL A.I.R. (kA) RMS Symmetrical Amperes

Volts AC (50/60 Hz)

120 120/240 240

BG

2 15 - 30 10 - -

3 15 - 30 - 10 -

Subject to change without prior notice Order No.: CBSS-BLCUT-0709

All rights reserved Printed in USA © 2009 Siemens Energy & Automation, Inc.

Siemens Energy & Automation, Inc.

Industry Sector 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.

All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

tararj Text Box

T im e in

S ec o n d s

SIEMENS 20 A

Current in Amperes X 10 814614-TC20 rev. 0P September 2016

Siemens Industry Inc. Norcross, GA, 30092

For Max. Interrupting Rating

See table above.

For application and coordination purposes only. Based on 40°C ambient cold start. Connected with 4 feet of rated wire (75°C) per terminal. Tested in open air with current.

Types QP, BL, QT, QPH, BLH, HQP, HBL 60Hz 120/240 Volts

Interrupting Ratings

10 kA

22 kA

65 kA

Instantaneous Trip Table

QP, BL, QT

QPH, BLH

HQP, HBL

15 - 20

Time Current Characteristics Curve

Types QP, BL, QT, QPH, BLH, HQP, HBL 1 Pole

Rating Amperes Fixed Instantaneous Trip Amperes 185 - 320

Breaker Type Symetrical RMS Amperes

Circuit Breakers

Answers for industry.

Circuit breakers

Panelboard mounted, non-interchageable trip, molded case circuit breakers Types BL, BLH, HBL,BLF, BLHF, BLE, BLEF, BAF, BAFH, BG 125A Frame

Specifications:

• 120, 120/240, 240Vac max.

• UL Listed, File # E82615

• CSA and NOM Certified

• HACR Rated

• 40C Calibration

• Thermal / Magnetic Trip

• Molded Case Switch, 2 pole 30 - 60 Amperes

• HID Lighting, 1 & 2 pole 15, 20, 30 Amperes

• SWD duty--1 pole

15 - 20 Amperes

Enclosures: Not Applicable

Interruption ratings

Breaker Type No. of Poles Ampere Rating

UL A.I.R. (kA) RMS Symmetrical Amperes

Volts AC (50/60 Hz)

120 120/240 240

BL

1 10 - 70 10 10

2* 15 - 100 10

2 10 - 125 10

3 10 - 100 10

BLH

1 15 - 70 22 22

2 15 - 125 22

3 15 - 100 22

HBL

1 15 - 70 65 65

2 15 - 125 65

3 15 - 100 65

* UL listed for use on 3-phase grounded "B" systems

Ground-Fault Protection Class A - 5mA

Breaker Type No. of Poles Ampere Rating

UL A.I.R. (kA) RMS Symmetrical Amperes

Volts AC (50/60 Hz)

120 120/240 240

BLF

1 15 - 30 10 10 -

2 15 - 60 - 10 -

BLHF

1 15 - 30 22 22 -

2 15 - 60 - 22 -

Ground-Fault Protection 30mA

BLE

1 15 - 30 10 10 -

2 15 - 60 - 10 -

BLEH

1 15 - 30 22 22 -

2 15 - 60 - 22 -

Arc-Fault Circuit Interrupter

(AFCI)

BAF

1 15 - 20 10 10 -

2 15 - 20 - 10 -

BAFH

1 15 - 20 22 22 -

2 15 - 20 - 22 -

Factory Added Options For all Factory Modifications Consult Siemens for cost adders

Description

External Accessories

Field installable Padlocking Device for 1, 2, and 3 poles Handle Blocking Device

Pressure Wire Connectors Load Side terminal factory installed only non-UL 50C calibration

400 Hz Calibration

415V, 50Hz Calibration

Fungus Proofing Ampere Rating

Cables Per Lug

Wire Range UL listed 5kA max. A.I.R.

non-UL 1 & 2 poles only

External Accessories (Factory Installed only)

15 - 20 1 #14 - #10 AWG Cu.

1 #12 - #10 AWG Al

25 - 35 1 #14 - #6 AWG Cu.

1 #12 - #6 AWG Al.

Shunt Trip Auxiliary Switch 40 - 50 1 #8 - #6 AWG Cu.

1 #8 - #4 AWG Al.

1 0 55 - 70

1 #8 - #4 AWG Cu.

0 1 1 #8 - #2 AWG Al.

(adds 1 pole width to left side of circuit breaker) 80 - 100

1 #4 - #1/0 AWG Cu.

1 #2 - #1/0 AWG Al.

110 - 125 1 #2 - #1/0 AWG Cu.

1 #1/0 - #2/0 AWG Al.

Note: Molded Case Circuit Breakers having a rated ampacity of 125 amperes or less are to be connected with 60 or 75C wire. Exceptions of this rule are outlined in article 110-12 C of the National Electrical Code.

Switching Neutrals

Breaker Type No. of Poles Ampere Rating

UL A.I.R. (kA) RMS Symmetrical Amperes

Volts AC (50/60 Hz)

120 120/240 240

BG

2 15 - 30 10 - -

3 15 - 30 - 10 -

Subject to change without prior notice Order No.: CBSS-BLCUT-0709

All rights reserved Printed in USA © 2009 Siemens Energy & Automation, Inc.

Siemens Energy & Automation, Inc.

Industry Sector 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.

All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

tararj Text Box

T im e in

S ec o n d s

SIEMENS 20 A

Current in Amperes X 10 814614-TC20 rev. 0P September 2016

Siemens Industry Inc. Norcross, GA, 30092

For Max. Interrupting Rating

See table above.

For application and coordination purposes only. Based on 40°C ambient cold start. Connected with 4 feet of rated wire (75°C) per terminal. Tested in open air with current.

Types QP, BL, QT, QPH, BLH, HQP, HBL 60Hz 120/240 Volts

Interrupting Ratings

10 kA

22 kA

65 kA

Instantaneous Trip Table

QP, BL, QT

QPH, BLH

HQP, HBL

15 - 20

Time Current Characteristics Curve

Types QP, BL, QT, QPH, BLH, HQP, HBL 1 Pole

Rating Amperes Fixed Instantaneous Trip Amperes 185 - 320

Breaker Type Symetrical RMS Amperes

Manual Switch

Manual Control Fractional HP starters, Class SMF

Class SMF Class SMF fractional horsepower starters provide overload protection as well as manual on-off control for small horsepower motors in a variety of industrial and commercial applications. Available in one or two pole versions, these devices are suitable for use with AC single phase motors up to 1 HP. Two pole starters can also be used with DC motors up to 3⁄4 HP. Typical applications include fans, conveyors, pumps and small machine tools.

Continuous Current Rating

• 16 amperes

Overload Trip Assembly Motor protection is provided by a Class SMFH heater element which must be installed before the starter will operate.

Enclosures Class SMF, NEMA Type 1 surface mounting enclosures are sheet steel with a thermo-plastic wrap-around cover for convenience in wiring. A zinc alloy die casting is used for NEMA Type 4 enclosures.

Mounting Open types without a pilot light fit standard single gang switch boxes, and can be used with any cover plate having a standard toggle cutout.

Volts

Maximum horsepower

AC Single phase DC

1-Pole 2-Pole 2-Pole

115–230 1 1 3⁄4

277 1 1 —

Accessories – Class SMF

Description Catalog Number

Handle guard kit with padlock provision SMFFL1

Starter – Class SMF, Single Phase 1

Type of operator

No of Poles

Starter Features

Open Type

NEMA Type 1

General Purpose enclosure, surface mounting

NEMA Type 3R, 4 & 12 watertight, dust-tight, metallic enclosure with clear cover

NEMA Type 4 watertight, dust-tight, metallic enclosure

Catalog Number Catalog Number Catalog Number Catalog Number

Toggle

Standard SMFF01 SMFFG1 SMFFWN1 —

Red Pilot Light SMFF01P SMFFG1P —

Standard SMFF02 SMFFG2 SMFFWN2 —

Red Pilot Light SMFF02P SMFFG2P —

Handle with Handle Guard/Lock-off – Class SMF, Single Phase 1

Toggle 1 Standard — SMFFG5 — SMFFW12

Red Pilot Light — SMFFG5P — SMFFW1P 2

Class SMF Starter in a NEMA Type 1 Enclosure without Pilot Light

1 One heater element required.

2 Furnished with (1) 3⁄4" NPT Outlet in bottom (reversible for top feed).

Ordering Information

1. Determine number of heater elements required from Table A.

2. Determine motor full load current and service factor.

3. If the motor and controller are in the same ambient temperature:

a. For 1.15 to 1.25 service factor motors, use 100% of motor full load current for heater element selection.

b. For 1.0 service factor motors use 90% of motor full load current for heater element selection.

c. Heater elements are class 20.

4. If the motor and controller are in different ambient temperatures, multiply motor full load current by the multiplier in Table B. Use the resultant full load current for heater element selection.

5. Select proper heater element from table below.

6. All tables are based on the operation of the motor and controller in the same ambient temperature, 40°C (104°F) or less. Always be certain the correct heater element is installed in the starter before operating the motor.

Heater Elements Class SMF

Catalog Number

Motor Full-Load Current (Amps)

SMFH01 0.157–0.173

SMFH02 0.174–0.192

SMFH03 0.193–0.212

SMFH04 0.213–0.235

SMFH05 0.236–0.261

SMFH06 0.262–0.289

SMFH07 0.290–0.321

SMFH08 0.322–0.355

SMFH09 0.356–0.399

SMFH10 0.41–0.44

SMFH11 0.45–0.49

SMFH12 0.50–0.53

SMFH13 0.54–0.58

SMFH14 0.59–0.65

SMFH15 0.66–0.71

SMFH16 0.72–0.78

SMFH17 0.79–0.85

SMFH18 0.86–0.96

SMFH19 0.97–1.04

SMFH20 1.05–1.16

SMFH21 1.17–1.25

SMFH22 1.30–1.39

SMFH23 1.38–1.54

SMFH24 1.48–1.63

SMFH25 1.57–1.75

SMFH26 1.66–1.86

Catalog Number

Motor Full-Load Current (Amps)

SMFH27 1.80–1.99

SMFH28 1.96–2.15

SMFH29 2.16–2.38

SMFH30 2.39–2.75

SMFH31 2.76–2.84

SMFH32 2.85–3.06

SMFH33 3.07–3.45

SMFH34 3.46–3.70

SMFH35 3.71–4.07

SMFH36 4.08–4.32

SMFH37 4.33–4.90

SMFH38 4.91–5.35

SMFH39 5.36–5.85

SMFH40 5.86–6.41

SMFH41 6.42–6.79

SMFH42 6.80–7.57

SMFH43 7.58–8.15

SMFH44 8.16–8.98

SMFH45 8.99–9.67

SMFH46 9.68–9.95

SMFH47 9.96–10.8

SMFH48 10.9–12.1

SMFH49 12.2–13.1

SMFH50 13.2–13.9

SMFH51 14.0–15.0

SMFH52 15.1–16.0

Heater Motor Full-Load List

Device

Number of Heater Elements Notes

SMFF*1

SMFF*2

SMFF*3

SMFF*4

SMFF*5

SMFF*6

All single pole and two pole SMF starters require only one Heater Element.

SMFF*22

SMFF*44

2 Duplex Unit. One Heater Element per starter.

SMFF*11

SMFF*22

Two Speed Starter. One Heater Element per speed.

Ambient Temperature of Motor

Continuous Duty Motor Service Factor

Same as Controller Ambient

Constant 10ºC (18ºF) Higher than Controller Ambient

Constant 10ºC (18ºF) Lower than Controller Ambient

1.15 to 1.25 1.0 0.9 1.05

1.0 0.9 0.8 0.95

Table A – Number of Heater Elements

Table B – Special Applications Heater Element Selection

Starter – Class SMF, Single Phase 1

Type of operator

No of Poles

Starter Features

Open Type

NEMA Type 1

General Purpose enclosure, surface mounting

NEMA Type 3R, 4 & 12 watertight, dust-tight, metallic enclosure with clear cover

NEMA Type 4 watertight, dust-tight, metallic enclosure

Catalog Number Catalog Number Catalog Number Catalog Number

Toggle

Standard SMFF01 SMFFG1 SMFFWN1 —

Red Pilot Light SMFF01P SMFFG1P —

Standard SMFF02 SMFFG2 SMFFWN2 —

Red Pilot Light SMFF02P SMFFG2P —

Handle with Handle Guard/Lock-off – Class SMF, Single Phase 1

Toggle 1 Standard — SMFFG5 — SMFFW12

Red Pilot Light — SMFFG5P — SMFFW1P 2

Manual Control Heater Elements, Class SMF

USDA Animal Holding Area

10/19/2018 18-56134-2

LIGHT SOURCE

8719 CASTLE PARK DR

INDIANAPOLIS, IN 46256-1272

Phone: 317-598-6900 Fax: 317-598-6910 Contact: Foreman, Andrew

GT8 F 2 32 FW A12 120 DMHL3D

LP835

L1 ABL-Lithonia Lighting

GT8 F 2 32 FW A12 120 DMHL3D

EL LP835

L1-EM ABL-Lithonia Lighting

ECC R M6X ABL-Lithonia Lighting

MA-R-IVDIM R LUTRON

MRF2-F6AN-DV-IVDIM M LUTRON

Catalog NumberManufacturer/BrandType

Project 18-56134-2 USDA Animal Holding Area

Submitted By

LIGHT SOURCE

FEATURES & SPECIFICATIONS

INTENDED USE —Static T8 fixtures provide general illumination for recessed applications; idea for restricted plenum spaces.

ATTRIBUTES — Designed exclusively for use with T8 lamps, electronic ballasts and sockets.

CONSTRUCTION — Smooth hemmed sides and smooth, inward formed end flanges for safe handling.

Lighter weight fixture allows for safe, easy installation.

Standard steel door frame has superior structural integrity with premium extruded appearance and precision flush mitered corners. Powder painted, steel latches provide easy, secure door closure.

Superior mechanical light seal requires no foam gasketing. Integral T-bar clips secure fixture to T-bar system. Housing formed from cold-rolled steel. Acrylic shielding material 100% UV stabilized. No asbestos is used in this product.

FINISH — Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance.

Painted parts finished with high-gloss, baked white enamel.

OPTICAL — Broad range of lens options available.

ELECTRICAL — Standard ballast is electronic, thermally protected, resetting, Class P, HPF, non-PCB, UL Listed, CSA certified ballast, universal voltage and sound rated A.

Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures.

LISTING — Standard: UL. Optional: Canada — CSA or cUL; Mexico — NOM.

WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

US patents: 6,210,025; 6,231,213; 2,288,471.

Note: Actual performance may differ as a result of end-user environment and application.

Specifications subject to change without notice.

Static Troffer

GT8 1'x4' 1, 2 or 3 Lamps

Specifications

Length: 48 (121.8)

Width: 12 (30.5)

Depth: 4-1/2 (11.4)

Weight: 17 lbs (7.7 kg) All dimensions are inches (centimeters).

NOTES:

1. Available with flush door frames only.

2. MVOLT standard for 120-277V applications, 50-60hz operations require voltage specified.

3. Must specify voltage 120 or 277.

GT8

Series Trim type Number of lamps Lamp type Door frame Diffuser type Voltage Options

GT8 1' wide (blank) Grid F Overlapping flanged

Not included

32 32W T8 (48") (blank) Flush steel, white

FN Flush aluminum, natural

FM Flush aluminum, matte black

FW Flush aluminum, white

RN Regressed aluminum, natural

RW Regressed aluminum, white

A12 #12 pattern acrylic

A12125 #12 pattern acrylic, .125" thick

A19 #19 pattern acrylic, .156" thick

A15 #15 pattern acrylic, .2" thick

PC1S 1/2" x 1/2" x 1/2" plastic cube louver, silver

PC2S 1-1/2" x 1-1/2" x 1" plastic cube louver, silver w/ flange1

MVOLT2

Others available

1/3 One 3-lamp ballast GEB10IS Electronic ballast, <10% THD, instant start GEB10RS Electronic ballast, <10% THD, rapid start EL 500 nominal lumen battery pack (non-CEC compliant) EL14 1400 nominal lumen battery pack (non-CEC compliant) EL14 T20C 1400 nominal lumen battery pack, CEC compliant GLR Internal fast-blow fuse3 GMF Internal slow-blow fuse3 LST Tandem-wired fixture pairs

(shared ballasts) PWS1836 6' prewire, 3/8" dia., 18-gauge, 1 circuit LP_ Lamped, specify lamp type and color PAF Painted after fabrication

(white enamel) SSR Specular silver interior finish

(95% reflective) CRE Flanged trim for continuous row mounting (end) CRM Flanged trim for continuous row mounting (middle) JP Palletized and stretch-wrapped without individual cartons; grid trim only

CSA CSA Certified NOM NOM Certified

ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: GT8 2 32 A12 MVOLT GEB10IS

Catalog Number

Notes

Type

FLUORESCENT: GT8-1X4

D

L

PS

PROVIDED WITH ECO 10 DRIVER-DMHL3D

F 2 32 A12 DMHL3D LP835120

Catalog Number

GT8 F 2 32 FW A12 120 DMHL3D LP835

Notes

Type

L1 Project 18-56134-2 USDA Animal Holding Area

MOUNTING DATA

Continuous row mounting of flanged units requires CRE and CRM trim options (see Options).

GT8 1'x4' Static Troffer

DIMENSIONS

All dimensions are inches (centimeters) unless otherwise indicated.

NOTE:

1 Recommended rough-in dimensions for F-trim fixtures 12"x48" (Tolerance is +1/4"-0"). Swing-gate range

1-9/16" to 3-3/4". Swing-gate span 10-3/4" to 14-3/4".

PHOTOMETRICS

Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%.

Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request.

GT8-1X4

FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com ©2009-2017 Acuity Brands Lighting, Inc. All rights reserved. Rev. 10/27/17

4-1/2 (11.4)

12 (30.5)

2-1/2 (6.4)

LC

4-1/2 (11.4)

12 (30.5)

2-1/2 (6.4)

LC

Coefficients of Utilization pf 20% pc 80% 50% 30% pw 70% 50% 30% 50% 30% 10% 50% 30% 10%

R C

R

Zonal Lumen Summary

Zone Lumens % Lamp % Fixture 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 180° 0° - 180°

25.8 41.2 66.3 77.7 0.0 77.7

33.2 53.0 85.3

100.0 0.0

100.0

Report:

LUMENS PER LAMP:

LTL12536

Luminaire Efficiency: 77.7%

GT8 2 32 A12

Catalog Number

GT8 F 2 32 FW A12 120 DMHL3D LP835

Notes

Type

L1 Project 18-56134-2 USDA Animal Holding Area

FEATURES & SPECIFICATIONS

INTENDED USE —Static T8 fixtures provide general illumination for recessed applications; idea for restricted plenum spaces.

ATTRIBUTES — Designed exclusively for use with T8 lamps, electronic ballasts and sockets.

CONSTRUCTION — Smooth hemmed sides and smooth, inward formed end flanges for safe handling.

Lighter weight fixture allows for safe, easy installation.

Standard steel door frame has superior structural integrity with premium extruded appearance and precision flush mitered corners. Powder painted, steel latches provide easy, secure door closure.

Superior mechanical light seal requires no foam gasketing. Integral T-bar clips secure fixture to T-bar system. Housing formed from cold-rolled steel. Acrylic shielding material 100% UV stabilized. No asbestos is used in this product.

FINISH — Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance.

Painted parts finished with high-gloss, baked white enamel.

OPTICAL — Broad range of lens options available.

ELECTRICAL — Standard ballast is electronic, thermally protected, resetting, Class P, HPF, non-PCB, UL Listed, CSA certified ballast, universal voltage and sound rated A.

Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures.

LISTING — Standard: UL. Optional: Canada — CSA or cUL; Mexico — NOM.

WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

US patents: 6,210,025; 6,231,213; 2,288,471.

Note: Actual performance may differ as a result of end-user environment and application.

Specifications subject to change without notice.

Static Troffer

GT8 1'x4' 1, 2 or 3 Lamps

Specifications

Length: 48 (121.8)

Width: 12 (30.5)

Depth: 4-1/2 (11.4)

Weight: 17 lbs (7.7 kg) All dimensions are inches (centimeters).

NOTES:

1. Available with flush door frames only.

2. MVOLT standard for 120-277V applications, 50-60hz operations require voltage specified.

3. Must specify voltage 120 or 277.

GT8

Series Trim type Number of lamps Lamp type Door frame Diffuser type Voltage Options

GT8 1' wide (blank) Grid F Overlapping flanged

Not included

32 32W T8 (48") (blank) Flush steel, white

FN Flush aluminum, natural

FM Flush aluminum, matte black

FW Flush aluminum, white

RN Regressed aluminum, natural

RW Regressed aluminum, white

A12 #12 pattern acrylic

A12125 #12 pattern acrylic, .125" thick

A19 #19 pattern acrylic, .156" thick

A15 #15 pattern acrylic, .2" thick

PC1S 1/2" x 1/2" x 1/2" plastic cube louver, silver

PC2S 1-1/2" x 1-1/2" x 1" plastic cube louver, silver w/ flange1

MVOLT2

Others available

1/3 One 3-lamp ballast GEB10IS Electronic ballast, <10% THD, instant start GEB10RS Electronic ballast, <10% THD, rapid start EL 500 nominal lumen battery pack (non-CEC compliant) EL14 1400 nominal lumen battery pack (non-CEC compliant) EL14 T20C 1400 nominal lumen battery pack, CEC compliant GLR Internal fast-blow fuse3 GMF Internal slow-blow fuse3 LST Tandem-wired fixture pairs

(shared ballasts) PWS1836 6' prewire, 3/8" dia., 18-gauge, 1 circuit LP_ Lamped, specify lamp type and color PAF Painted after fabrication

(white enamel) SSR Specular silver interior finish

(95% reflective) CRE Flanged trim for continuous row mounting (end) CRM Flanged trim for continuous row mounting (middle) JP Palletized and stretch-wrapped without individual cartons; grid trim only

CSA CSA Certified NOM NOM Certified

ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: GT8 2 32 A12 MVOLT GEB10IS

Catalog Number

Notes

Type

FLUORESCENT: GT8-1X4

D

L

PS

PROVIDED WITH ECO 10 DRIVER-DMHL3D

F 2 32 A12 DMHL3D EL LP835120

Catalog Number

GT8 F 2 32 FW A12 120 DMHL3D EL LP835

Notes

Type

L1-EM

Project 18-56134-2 USDA Animal Holding Area

MOUNTING DATA

Continuous row mounting of flanged units requires CRE and CRM trim options (see Options).

GT8 1'x4' Static Troffer

DIMENSIONS

All dimensions are inches (centimeters) unless otherwise indicated.

NOTE:

1 Recommended rough-in dimensions for F-trim fixtures 12"x48" (Tolerance is +1/4"-0"). Swing-gate range

1-9/16" to 3-3/4". Swing-gate span 10-3/4" to 14-3/4".

PHOTOMETRICS

Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%.

Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request.

GT8-1X4

FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800-858-7763 Fax: 770-929-8789 www.lithonia.com ©2009-2017 Acuity Brands Lighting, Inc. All rights reserved. Rev. 10/27/17

4-1/2 (11.4)

12 (30.5)

2-1/2 (6.4)

LC

4-1/2 (11.4)

12 (30.5)

2-1/2 (6.4)

LC

Coefficients of Utilization pf 20% pc 80% 50% 30% pw 70% 50% 30% 50% 30% 10% 50% 30% 10%

R C

R

Zonal Lumen Summary

Zone Lumens % Lamp % Fixture 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 180° 0° - 180°

25.8 41.2 66.3 77.7 0.0 77.7

33.2 53.0 85.3

100.0 0.0

100.0

Report:

LUMENS PER LAMP:

LTL12536

Luminaire Efficiency: 77.7%

GT8 2 32 A12

Catalog Number

GT8 F 2 32 FW A12 120 DMHL3D EL LP835

Notes

Type

L1-EM

Project 18-56134-2 USDA Animal Holding Area

Catalog Number

Notes

Type

CONTRACTOR SELECT ECC Page 1 of 2

ECC

Low Profile Emergency Light/Exit Combo

The low-profile, Lithonia Ligthing® ECC, LED light, is a combination of exit and emergency lighting. It's low profile design with small, unobtrusive dual lamp heads makes the ECC ideal for safely illuminating the path of egress above-the-door in small spaces at lower mounting heights while providing 90 minutes of emergency power. Available in red and green letters.

FEATURES:

¡ Test switch and status indicator

¡ UL Indoor damp location 50° to 104°F (10°C to 40°C) listed standard

¡ For use with Dual voltage 120/277VAC

Accessories: Order as separate catalog number.

ERE SGL Single, indoor remote head, white, 0.75W, 3.6V. See spec sheet ERE.

ERE T Twin, indoor remote head, white, 1.75W, 3.6V. See spec sheet ERE.

ERE GY SGL WP Single, weather-proof remote head, gray, 1W, 3.6V-12V voltage sensing. See spec sheet ERE.

ELA WG3 Wireguard, 30" W x 13-1/2" H x 6" D. See spec sheet ELA-WG.

ELA WG2M Wireguard, 21-1/4" W x 15" H x 12" D. See spec sheet ELA-WG.

Contractor Select™

Catalog Number UPC Description Supply Voltage

Input Wattage Input Amps Pallet Qty

Carton Qty120 277 120 277

ECC R M6 191848035597 LED Exit/Unit Combo Red 120/277V 1.1W 1.3W .08 .09 360 6

ECC R REM M6 191848035702 LED Exit/Unit Combo Red with 2W of remote capacity 120/277V 1.6W 1.6W .10 .11 360 6

ECC G M6 191848035733 LED Exit/Unit Combo Green 120/277V 1.1W 1.3W .08 .09 360 6

ECC G REM M6 191848035740 LED Exit/Unit Combo Green with 2W of remote capacity 120/277V 1.6W 1.6W .10 .11 360 6

Battery Total Capacity Maximum# Remote Lamp Heads*

3.6V 4W

2 - ERE SGL M24

1 - ERE T M24

2 - ERE GY SGL WP M12

* Remotes are in addition to the lamp heads on the product.

Battery Capacity and Loading (REM only)

Catalog Number

ECC R M6

Notes

Type

X Project 18-56134-2 USDA Animal Holding Area

One Lithonia Way, Conyers, GA 30012 | 800-334-8694 | techsupport-emergency@acuitybrands.com | www.lithonia.com © 2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/08/18 Page 2 of 2

CONTRACTOR SELECT ECC

INTENDED USE:

Provides a minimum of 90 minutes illumination for the rated wattage upon loss of AC power to meet code required emergency lighting. Ideal for applications requiring low profile, emergency unit for lower mounting heights.

CONSTRUCTION:

The housing is a standard white thermoplastic with a compact and low-profile design with all-inclusive lamp, reflector and lens assembly. It is 5VA flame rated and impact-resistant.

OPTICS:

The typical life of the LED is 10 years. One, 0.75W white LED per lamp head.

ELECTRICAL:

Dual-voltage 120/277 standard.

Bi-color LED status indicator for battery condition. (Green-normal, Red-check battery).

Two and a half watts of additional remote capacity with ECC R REM M6 and ECC G REM M6.

BATTERY: 3.6V Maintenance-free, rechargeable, nickel-cadmium.

INSTALLATION:

Top, side and back mount. Mounting pattern on canopy (top and side mount) and back plate (back mount) fits most standard size junction boxes.

LISTINGS:

UL Listed. Meets all applicable requirements for UL 924, NFPA 101 (current Life Safety Code), NFPA 70 (NEC), FCC and OSHA.

Indoor damp location 50° to 104°F (10°C to 40°C) listed.

WARRANTY:

2-year limited warranty. Complete warranty terms located at:

www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Actual performance may differ as a result of end-user environment and application.

All values are design or typical values, measured under laboratory conditions at 25 °C.

Specifications subject to change without notice.

Specifications Dimensions

Length: 16 (40.64) Depth: 11.94 (33.33) Height: 7.25 (18.52) Weight: 2.15lbs (.98kg)

All dimensions are inches (centimeters) unless otherwise indicated.

Catalog Number

ECC R M6

Notes

Type

X Project 18-56134-2 USDA Animal Holding Area

MAESTRO CONTROLS

Smart Dimmers Smart Remotes

Have Questions? Call the Lutron Hotline 800-523-9466 To order—Call Lutron Customer Service 610-282-3800

JOB NAME AREA CONTROLLED

LOCATION JOB NUMBER

TITLE PAGE NO.

STANDARDS

SPECIFICATION SUBMITTAL

PRODUCT FAMILY FEATURES

• High-tech “Smart Dimmer” with microprocessor technology for a standard designer wallplate opening

• Features a clean, flush, stylish appearance

• Special Features! Two taps on the switch brings lights on to full brightness; press and hold the switch to slowly fade lights to off over 10 seconds

• LED’s indicate light level and glow softly as a locator light in the dark

• Multi-location dimming from up to 10 locations

• Uses standard single-pole and 3-way wiring for easy installation in any home

• Raise from off

SPECIFICATION FEATURES

• Power- failure memory

• Frequency compensation

• Includes Radio Frequency Interference suppression

• Front accessible service switch (FASSTM) to disconnect load power

• Electrostatic discharge tested

• Precise color matching across all controls

The High-Tech Multi-Location Dimmer

Smart Dimmer

Switch

Rocker Switch

Jacks Ports

Custom Multigang Wallplates

15A Receptacle

15A GFCI

Receptacle

Single Telephone Jack

Cable

TV

Jack

2-gang to 6-gang wallplates

6-Port Frame

® Controls www.lutron.com/maestro

One tap on to selected light level/off; two taps full bright;

press & hold for 10-second fade off Press rocker to adjust light level Front accessible service switch

(FASSTM)

LED’S indicate light level, glow softly

CLARO ACCESSORIES

Note: For multi-location dimming only-use one Smart Dimmer (left) with up to nine Smart Remotes

Receptacles

Catalog Number

MA-R-IV

Notes

Type

DIM R

Project 18-56134-2 USDA Animal Holding Area

2 Have Questions? Call the Lutron Hotline 800-523-9466 To order—Call Lutron Customer Service 610-282-3800

Description Model #

SMART DIMMERS

Incandescent Preset Smart Dimmers

Single Pole/Multi-Location 600W MA-600-

Single Pole/Multi-Location 1000W MA-1000- Products above: For multi-location dimming, use one Maestro Smart Dimmer with up to nine Maestro Smart Remotes, MA-R-. Not for use with mechanical 3-way or 4-way switches. Minimum load on dimmer is 40W. Derating required if ganged, see page 5.

Electronic Low Voltage Preset Smart Dimmers

Single Pole/Multi-location 600W MAELV-600- Products above: For multi-location dimming, use one Maestro Smart Dimmer with up to nine Maestro Smart Remotes, MA-R-. Requires neutral wire connection. Not for use with mechanical 3-way or 4-way switches. Minimum load on dimmer is 5W. Derating required if ganged, see page 5.

Magnetic Low Voltage Preset Smart Dimmers

Single Pole/Multi-Location 600VA (450W 1) MALV-600-

Single Pole/Multi-Location 1000VA (800W 1) MALV-1000- Products Above: For Multi-location dimming, use one Maestro Smart Dimmer with up to nine Maestro Smart Remotes, MA-R-. Not for use with mechanical 3-way or 4-way switches. Minimum load on dimmer is 40W. Derating required if ganged, see page 5.

Fluorescent For control of fluorescent loads, use Lutron Hi-lume®, Eco 10TM line voltage, or Tu-Wire® electronic dimming ballasts with MA-600- and Hi-Power 2• 4•6 dimming module. For a coordinated look, consider using Spacer System dimmers for controlling fluorescent loads.

HI-POWER 2•4•6TM DIMMING MODULES

To increase load capacity up to 30,000W/VA in most popular sources, use one MA-600- and add up to five dimming modules.

SMART REMOTES

Provide Multi-Location Dimming from up to Nine Additional Locations.

Smart Remotes

Smart Remotes MA-R- For multi-location dimming, use up to nine Smart Remotes with only one of the following Maestro multi-location dimmers: MA-600-, MA-1000-, MAELV-600-, MALV-600-, or MALV-1000-. No derating required if ganged. Maximum traveler wiring run for multi-location applications is 250’ (76.2m).

® Controls www.lutron.com/maestro

1. Actual lamp wattages.

Catalog Number

MA-R-IV

Notes

Type

DIM R

Project 18-56134-2 USDA Animal Holding Area

6 Have Questions? Call the Lutron Hotline 800-523-9466

Wiring Diagram 2 Multi-Location Wiring Model #

MA-R-

MA-600-

MA-1000-

MALV-600-

MALV-1000-

OR

Control Line Side

Neutral

Red

Blue

Multi-Location Dimmer

Smart Remote

Smart Remote

Smart Remote

Black BlackHot

Up to Nine Total Auxiliary Switches/Remotes

120VAC

60Hz Green Green Green GreenBlue

Red Black

Blue

Red Black

Blue Lighting Load

Red

Grou

Wire

Smart Remote

Smart Remote

Smart Remote

Up to Nine Total Auxiliary Switches/Remotes

GreenGreenGreenGreen

Neutral

Black

Blue

Multi-Location Dimmer

Red RedHot

120VAC

60Hz Blue

Black Red

Blue

Black Red

Blue Lighting Load

Black

Control Load Side

Ground

Wire Connectors

Ground

Wire Connectors

WIRING DIAGRAMS

Wiring Diagram 1 Single-Location Wiring Model #

MA-600-

MA-1000-

MALV-600-

MALV-1000-

® Controls www.lutron.com/maestro

Green

Dimmer/ TapSwitch™

Black Red

Blue Cap Off Lighting

Load

Neutral

Hot

120VAC

60Hz

Ground

Wire Connectors

Catalog Number

MA-R-IV

Notes

Type

DIM R

Project 18-56134-2 USDA Animal Holding Area

7 Have Questions? Call the Lutron Hotline 800-523-9466

® Controls www.lutron.com/maestro

Wiring Diagram 6 Telephone Jack Wiring Model #

CA-PJH-

Wiring Diagram 7 Receptacle Wiring Model #

CAR-15H-

Wiring Diagram 8 GFCI Receptacle Wiring Model #

CAR-15-GFCIH-

WIRING DIAGRAMS

Wiring Diagram 4 Multi-Location Control with Neutral Used for Single-Location Wiring Model #

MAELV-600-

Wiring Diagram 5 Multi-Location Wiring Model #

MAELV-600-

MA-R-

Ground

Neutral

Hot

Black

White

Green or Screw Terminal

Green or Screw Terminal

Green or Screw Terminal

Black

White

120VAC

60Hz

GFCI

Receptacle (15A Shown)

NPNP PP PP

Line Load

Wire ConnectorsP-Protected NP-Not Protected

Building Ground (To Metal Box)

Smart Remote

Multi-Location Dimmer

Green Green Lighting Load

Neutral

Black

Blue

White

BlackRed YellowHot

120VAC

60Hz Blue

Up to Nine Total MA-R Units

Control Load Side

Ground

Wire Connectors

Neutral

Green

Black

Dimmer/ TapSwitch

Yellow

Blue

Hot

120VAC

60Hz

Lighting LoadWhite

Cap Off

Ground

Wire Connectors

6-Conductor Telephone Jack*

Wire Color

Jack Position

1 White 2 Black 3 Red 4 Green 5 Yellow 6 Blue

* accepts most…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .