Exhibit_D_Price_Schedule_-_Event_18532_8-26.xls
XLS spreadsheet 165 KB Posted
- Attached to
- PREVENTIVE MAINTENANCE - BACKUP GENERATORS
- Solicitation number
- 2000018532
- Issued by
- Minnesota
About this file
This is a Price Schedule Exhibit D for a formal Request for Proposal issued by the State of Minnesota for preventive maintenance and repair services on backup generators located at various state facilities. The contract encompasses multiple Minnesota agencies and locations, including Moose Lake State Operating Premises (MSOP), Minnesota Correctional Facilities (MCF) at Moose Lake, Oak Park Heights, and Rush City, Minnesota State Lottery facilities in Roseville and Owatonna, Minnesota Department of Transportation Materials Lab in Maplewood, Minnesota Department of Natural Resources Crystal Springs State Fish Hatchery in Altura, and Minnesota Veterans Homes in Bemidji, Fergus Falls, Luverne, Minneapolis, Montevideo, Preston, and Silver Bay. The solicitation requests pricing for preventive maintenance services including 64-point inspections, 67-point inspections, cooling system services, megohmmeter testing, load bank testing, engine and generator inspection and adjustment, battery inspection and replacement, and fuel testing and sampling for generators ranging from 30 KW to 2,000 KW across five fiscal years from January 1, 2027, through October 31, 2031. The contract term is two years with optional extensions up to three additional years, beginning November 1, 2026, or upon contract execution, whichever is later, through October 31, 2028. A non-mandatory site visit deadline was September 4, 2026, and the question submission deadline was September 7, 2026, at 3:00 PM CST.
The price schedule requires responders to submit pricing for maintenance line items at specified intervals throughout the contract period, with particular emphasis on load bank testing for four high-voltage 3512 Caterpillar generators that require step-down transformers. Pricing sections include hourly rates for regular hours (Monday through Saturday, 7:30 a.m. to 4:00 p.m.), overtime hours (Monday through Saturday, 4:01 p.m. to 7:29 a.m.), and Sundays and state-designated holidays, as well as standby generator rental rates provided on a per 24-hour day and per 7-day week basis. Responders must also provide cost-plus percentage markups for parts and materials for both repairs and stock purchases, with invoices from suppliers to be provided to the State. The contract excludes sales tax on parts and materials purchases, as state agencies pay Minnesota sales and use taxes directly to the Department of Revenue using Direct Payment Permit 1114. All responses must be submitted on the provided Exhibit D Price Schedule or risk rejection, and responses must be submitted in non-electronic format by the specified deadline.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Facilities
| EXHIBIT D: PRICE SCHEDULE - EVENT 18532 | ||||||||||
| Pricing shall be based on a two-year Contract with the option to extend up to three additional years. If the Contract is extended additional years the pricing provided for fiscal years 2029-2031 will be the pricing set forth for the additional years of services. | ||||||||||
| Provide pricing only on the line items requested below or your bid may be rejected. RESPONDERS MUST SUBMIT THEIR RESPONSE ON THIS EXHIBIT D PRICE SCHEDULE OR THE RESPONSE MAY BE REJECTED. | ||||||||||
| MSOP - MOOSE LAKE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: Caterpillar, GEN Model: SR-4, GEN Serial: 7AJ00552, Engine Model: 3412, Engine Serial: 2WJ00117, KW: 750KW, Voltage: 480V | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MSOP - MOOSE LAKE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: Caterpillar, GEN Model: SR-4, GEN Serial: G6J00542, Engine Model: 3512 PGAG, Engine Serial: 0SBG01038, KW: 1500KW, Voltage: 4160V Extended Warranty in Place Cannot be Voided | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| D. Megohmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| E. Load Bank Testing. Step Down Transformer Required - Include it in Load Bank Test Pricing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MSOP - MOOSE LAKE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: Caterpillar, GEN Model: SR-4, GEN Serial: G6J00543, Engine Model: 3512 PGAG, Engine Serial: 0SBG01039, KW: 1500KW, Voltage: 4160V Extended Warranty in Place Cannot be Voided | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| D. Megohmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| E. Load Bank Testing. Step Down Transformer Required - Include it in Load Bank Test Pricing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF - MOOSE LAKE POWER HOUSE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: Caterpillar, Serial: 024Z06622, Model: 3512, V.I.N. 2FN00531, 1250KW, Voltage: 4160. Extended Warranty in Place Cannot Be Voided. | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | |||||
| E. Load Bank Testing. Step Down Transformer Required - Include it in Load Bank Test Pricing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF - MOOSE LAKE POWER HOUSE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: Caterpillar, Engine Serial: 024Z06624, Model: 3512, V.I.N: 2FN00532, 1250KW, Voltage: 4160. Extended Warranty in Place Cannot Be Voided. | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | |||||
| E. Load Bank Testing. Step Down Transformer Required - Include it in Load Bank Test Pricing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF - MOOSE LAKE FENCE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: John Deere - Engine Serial: RG6076A200719, Model: 6076AF010, 150KW, Voltage: 480. | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | |||||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF - MOOSE LAKE WILLOW RIVER | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Manufacturer: Onan - Engine Serial: 37238105, Model GST30-G5, 750KW, Voltage: 208, V.I.N. L080225910 | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | |||||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF - OAK PARK HEIGHTS | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Cummins - Model: 2,000.0DQKC-5002154C; Serial: I010281496; 2000KW; Voltage: 480/277 | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF - OAK PARK HEIGHTS | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Cummins - Model: 680FDR7026; Serial: JK92636-9/24-4; 500KW; Voltage: 480/277 | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF- RUSH CITY | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Caterpillar Engine Serial: 25Z06042, Model: 3516 DITA Caterpillar Generator Serial:5WN00933, Model: SR-4 1500kW, Voltage: 480V | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MCF- RUSH CITY | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Caterpillar Engine Serial: 25Z06007, Model: 3516 DITA Caterpillar Generator Serial:5WN00967, Model: SR-4 1500kW, Voltage: 480V | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| MN STATE LOTTERY, ROSEVILLE | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Generator: 2015 Caterpillar Model LC7 |
Generator S/N G7A05400 Engine: Caterpillar Model C15 PGAN /300 /300 Engine S/N 00C15TNAP00983 / 1241237-002 RE/1241237-003 RE
| 500 KW, 208/120 Voltage | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 | |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | ||||||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | ||||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |
| MN STATE LOTTERY, OWATONNA | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 | |
| Cummins - Equipment Model: 70.0GGHF, Engine Model: 1514274; Serial: G150846135; 70KW; Voltage: 120/208 THIS IS A NATURAL GAS GENSET | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 | |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| D. Megohmmeter Testing - Simple Test | No Service | No Service | No Service | No Service | No Service | ||||||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |
| MNDOT Materials Lab | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 | |
| Equipment Model: Engine Model: Serial: Size: Voltage: Manufacturer: ONAN, GEN Model: 1250.0DFLC-4957497 Gen Serial: E010236974, KW1250, Voltage: 277/480 Volts | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 | |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | ||||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |
| MN DNR, Crystal Springs State Fish Hatchery | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 | |
| Generator: Onan 30EK L33689R |
Generator S/N 29007 F-26-77 30KW, Voltage: 120/208V Engine: Model number: CSG-6491-6005-A
| Serial number: 29007 F-28-77 | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 | |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | ||||||
| D. Megohmeter Testing | No Service | No Service | No Service | No Service | No Service | ||||||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | ||||||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | ||||||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | ||||||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | ||||||
| TOTAL PER COLUMN | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | |
| Minnsota Correctional Facility TOGO | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 | |
| Generac MG130, Model No.MG0130JG2690V18GPLYF, Serial No. 3005642351, Engine G9.0.1 9.0L year of manufacture 2020/01, 130KW | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 | |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | ||||||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| I. Auxiallry Electrical Transfer Switch Inspection and Adjustments | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| TOTAL PER COLUMN | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | |
| Minnsota Correctional Facility TOGO | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 | |
| Generac MG130, Model No.MG0130JG2690V18GPLYF, Serial No. 3005642352, Engine G9.0.1 9L year of manufacture 2020/01, 130KW | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 | |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | ||||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | ||||||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| I. Auxiallry Electrical Transfer Switch Inspection and Adjustments | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |
| TOTAL PER COLUMN | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | No Service | $ - 0 | |
| STANDBY GENERATOR RENTAL RATES | YEAR 1 & 2 - FY27 & FY28, & Part of FY 29 from November 1, 2026 through Oct. 31, 2028 | YEAR 3 - FY 29 and Part of FY30 from November 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 and Part of FY31 from November 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 and Part of FY32 from November 1, 2031 through Oct. 31, 2031 | |||||||
| RENTAL - MSOP - MOOSE LAKE | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum (750) KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MSOP - MOOSE LAKE | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 1500 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - MOOSE LAKE POWERHOUSE | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 1250 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - MOOSE LAKE FENCE | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 150 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - MOOSE LAKE WILLOW RIVER | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 750 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - OAK PARK HEIGHTS | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 500 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - OAK PARK HEIGHTS | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 2000 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - RUSH CITY | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 1500 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MN LOTTERY ROSEVILLE | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 200 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MN LOTTERY OWATONNA | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 200 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MNDOT MATERIAL LAB- MAPLEWOOD | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 1250 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MN DNR CRYSTAL SPRINGS FISH HATCHERY - ALTURA, MN | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 30 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| RENTAL - MCF - TOGO | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | Rental Per 24-Hour Day | Rental Per 7-Day Week | |||
| The Contractor may be required to provide a minimum 500 KW generator set capable of providing immediate back-up generation in the event of loss of utility power during the period of time the engine-generator is being repaired and unavailable to provide back up generation. | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | $____________ | |||
| REPAIRS: Hourly Rates for Emergencies and Time and Material Repairs on an As Needed Basis. | Per Hour Rate | Per Hour Rate | Per Hour Rate | Per Hour Rate | |||||||
| Regular Hours: Monday through Saturday 7:30 a.m. - 4:00 p.m. | $____________ | $____________ | $____________ | $____________ | |||||||
| Overtime Hours: Monday through Saturday 4:01 p.m. - 7:29 a.m. | $____________ | $____________ | $____________ | $____________ | |||||||
| Sundays and State designated Holidays: | $____________ | $____________ | $____________ | $____________ | |||||||
| Part/Materials for Repairs: | Percentage Mark-up | ||||||||||
| Any parts/materials needed for repairs not covered by the maintenance services will be invoiced as materials at cost-plus percentage mark-up including shipping. The percentage mark-up provided will be the mark-up for the life of the contract. The State will request from the Contractor copies of invoices from their supplier. | ________% | ||||||||||
| Tax Requirement for Inspection Services, Fuel Sampling, and Time and Material Repairs: The responder is understood to have included in its response price for furnishing and installing product any applicable State or Federal sales, excise or use tax on all materials, supplies and equipment that are to be utilized. The State’s Direct Pay permit will not apply for orders against the Contract. | |||||||||||
| Parts/Materials purchased for Stock: | Percentage Mark-up | ||||||||||
| Any parts/materials needed for stock will be invoiced as materials at cost-plus percentage mark-up including shipping. The percentage mark-up provided will be the mark-up for the life of the contract. The State will request from the Contractor copies of invoices from their supplier. | ________% | ||||||||||
| Tax Requirement for Parts purchase only: DO NOT add sales tax to the puchase of Parts/Material only. State agencies are subject to paying Minnesota sales and use taxes directly to Revenue. Taxes will be paid to the Department of Revenue using Direct Payment Permit 1114. |
&C&"-,Bold"&16M-459 PRICE SCHEDULE&"-,Regular"&14 &C&P
Veterans Homes
| EXHIBIT D: PRICE SCHEDULE - EVENT 18532 Minnesota Veterans Home, Bemidji | ||||||||||
| Minnsota Veterans Home - Bemidji | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Caterpillar, Model No 500, Engine Model C15, Manufacture Date 4/2023 S/N CAT00C15ET3301747 Power 625 KVA 500 KW 480 Volt RPM 1800 | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | |||||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | |||||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | |||||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | |||||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| I. Auxiallry Electrical Transfer Switch Inspection and Adjustments | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 |
| Minnesota Veterans Home, Fergus Falls | ||||||||||
| Minnesota Veterans Home - Fergus Falls | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Zeigler Cat- Product #:CAT00C32LSXCO5255, Generator Model SR4B-GD SS# G5B01120 Engine Model: C32, Serial # SYC05270, 1000 KW, Voltage: 480 Volts | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | |||||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | |||||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | |||||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| Minnesota Veterans Home, Luverne | ||||||||||
| Minnsota Veterans Home - Luverne | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| MTU Diesel engine, Model 1000RXC6DT2, Serial No. 315047-1-1-1109, Engine No.,16V2000-Detroit diesel, Engine Serial No. 536201002, year of manufacture 2009, RPM 1800, 1000KW Generator: Mfr Marathon, Model 741RSL4045, Serial No. WA-571152-1109 | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | No Service | No Service | |||
| TOTAL PER COLUMN | No Service | No Service | No Service | No Service | No Service | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 |
| Minnesota Veterans Home, Minneapolis | ||||||||||
| Minnsota Veterans Home - Minneapolis | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |
| Equipment: Caterpillar -Generator Model:SR4B HV Serial:G3ZOO323 Engine Model:3516c Size:2000KW Voltage: 480V | FALL 2026 | WINTER, SPRING, SUMMER, EARLY FALL 2027 | FALL 2027 | WINTER, SPRING, SUMMER, EARLY FALL 2028 | FALL 2028 | WINTER, SPRING, SUMMER, EARLY FALL 2029 | FALL 2029 | WINTER, SPRING, SUMMER, EARLY FALL 2030 | FALL 2030 | WINTER, SPRING, SUMMER, EARLY FALL 2031 |
| A. 64 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| B. 67 - Point Inspection | No Service | No Service | No Service | No Service | No Service | |||||
| C. Cooling System Services | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service |
| D. Megohmmeter Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| E. Load Bank Testing | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| F. Engine/Generator Inspect & Adjust | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| G. Battery Inspect & Replacement | No Service | No Service | No Service | No Service | No Service | No Service | No Service | No Service | ||
| H. Fuel Testing/Sampling | No Service | No Service | No Service | No Service | No Service | |||||
| TOTAL PER COLUMN | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ 1.00 | $ - 0 | $ - 0 |
| Minnsota Veterans Home - Minneapolis | YEAR 1 - FY27 | Year 1 - FY27 and Part of FY28, from January 1, 2027 through Oct. 31, 2027 | YEAR 2 - FY 28 | Year 2 - FY28 and Part of FY29, from January 1, 2028 through Oct. 31, 2028 | YEAR 3 - FY 29 | Year 3 - FY29 and Part of FY30, from January 1, 2029 through Oct. 31, 2029 | YEAR 4 - FY30 | Year 4 - FY30 and Part of FY31, from January 1, 2030 through Oct. 31, 2030 | YEAR 5 - FY31 | Year 5 - FY31 and Part of FY32, from January 1, 2031 through Oct. 31, 2031 |