Exhibit_3_-_Crypts-101-Field-Inspection-_-Protection.pdf

PDF 10 MB Posted

Attached to
Master Agreement AZ|CTR079530
Contract number
CTR079530
Issued by
Arizona

About this file

This document is a comprehensive presentation titled "PPC Field Install Inspection & Protection Crypts 101" created by the National Cemetery Administration (NCA). The slides are presented by Andrew J. Walters, PE, a Specialist in Cemetery Development & Improvement Service, and focus on guidelines for Pre-Placed Crypts (PPCs) installation and field inspection procedures.

The presentation provides detailed technical guidance for installing precast concrete burial crypts, covering critical aspects such as transportation, positioning, inspection protocols, and potential failure modes. Key recommendations include: setting crypts centered in 3-ft x 8-ft plots with 1/4-inch tolerance, using pea gravel to prevent lid movement, avoiding vehicle proximity that could cause structural damage, protecting newly installed crypts with signage and temporary fencing, and meticulously checking for cracks, fork damage, and proper numbering. The document emphasizes the importance of structural integrity, noting that minor concrete cracks less than 0.030 inches wide are acceptable if fiber reinforcement is engaged, and provides specific instructions for handling and protecting burial crypts during installation.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PPC Field Install Inspection & Protection Crypts 101

PPC - PrePlaced Crypts 6/29/2021

Andrew J. Walters, PE Specialist, Cemetery Development & Improvement Service (41A2) National Cemetery Administration

Crypts 101 slides to date:

1. Overall

2. Inspection & Protection

3. On-site Buried Testing

4. Wall Field Repair

National Cemetery Administration

PPC Field Inspection & Protection Crypts arriving on-site

PPC Field Inspection & Protection Check for fork damage. Thru-wall hole cause for rejection.

Dunnage

Crypts unloaded & set in staging area on dunnage preferred.

Check for outside cracks and apply spec tolerances.

Simplistic – credit card doesn’t fit into the crack means acceptable; fiber is doing its job.

PPC Field Inspection & Protection

ALLOWABLE

REJECTABLE

Chalk mark rejected crypts. Precasters not happy with paint.

Bottom line, it is the GC’s crypt until NCA pays for it.

Set crypts centered in sloped 3-ft x 8-ft plots to ¼” tolerance.

Do not allow creep which happens if not set in center of plot.

Aerial view of same.

Lock-in “set” crypts with pea gravel in gaps to stop crawl from vibratory rollers constructing roads adjacent PPC fields.

Rounded pea gravel flows like water into gaps.

Cut-aggregate must be rodded or causes surface issues.

PPC Field Inspection & Protection

Rounded

Cut

To avoid crawling of set PPCs without pea gravel in gaps, stop mini-earthquakes from:

Roller vibration “ON” during adjacent road construction.

Rock pulverizing.

Below absolutely critical!! Estimated one in ten PPC installs have some incorrect lid numbering.

Double check correct numbering with NCA Staff involved.

Wipe lid with rag & immediately paint #. (within seconds) After 1st interment bucket scraping, black lid # paint stays if in lid’s microscopic pores. Tested at WCNC. No red paint.

Use all 4 anchors lifting lids. Anchor won’t connect, reject lid.

Paint # high on inside-wall for GIS data collection.

PPC Field Inspection & Protection

National Cemetery Administration

NO diagonal lid lifting with only two wire ropes

If not vertical, knuckle won’t fit.

During lid lifting to paint inside wall #:

Check inside walls for cracks. Won’t be voids.

Check drainholes “clogging” from thin film of cement.

Recommend test inside-shelf for proper fit every 100 lid lifts.

PPC Field Inspection & Protection

National Cemetery Administration

Thru wall cracks – reject or repair.

Send pics & location to Crypt Specialist

Optionally, verify steel rebar present in lids & perimeter walls.

If rebar lacking, lid “cave-in” failure inevitable during backfill ops.

Inspect for shoved lids during pea gravel install into gaps.

Use rubber track vehicles to avoid shoved lids.

PPC Field Inspection & Protection

National Cemetery Administration

Shoved lid failures

Always ramp in backfill over lids!

Keep tall piles of fill AWAY from PPC field edge! Will collapse crypt walls!

Do NOT allow tall piles over or next to PPC fields during backfilling over lids. Tall piles will collapse crypt walls.

Probe soil depth to lid with rebar to 20” to 22” includes sod.

Affects headstone setting’s vertical stability forever.

Protect newly installed & backfilled PPCs with signage and…

Protect newly installed PPCs with temporary fencing or stakes with roping. High visibility Orange preferred.

Pre-Placed Crypts (PPCs) 101 Again, collapsed walls can happen if:

If watertrucks get within 10 yds of the PPC field

If concrete or asphalt trucks get within 10 yds of a PPC field.

If hydroseeding truck gets within 10 yds of a PPC field.

Ditto sod trucks. Ditto dumptrucks with 5-CY+ capacity.

If any vehicles of this ilk get near or over crypts, walls collapse.

Tall piles collapse crypts. Same as excessive wheel loads.

Send daily crypt install pics to Crypt Specialist so can advise on items of concern such as:

This vehicle will shove lids.

Any exposed rebar rejects lid or crypt. No repairs or patch.

NO two-point lid lifting.

Unsafe and all 4 lid anchors need “fit” check.

OMG, NO!

Send daily crypt install pics to Crypt Specialist so can advise of amazing feats like:

National Cemetery Administration

Expertise required for 10% grade PPC install.

Backfill by conveyor belts.

Like Death & Taxes, concrete cracks cannot be avoided and if minor, can cause zero loss of Structural Integrity & Functionality.

Minor cracks (not thru wall) less than 0.030” width engages fiber reinforcement thus maintains SI&F. Patching with a cement slurry or epoxy caulk is cosmetic.

Prior to any repairs, send pics of damaged crypt(s) with its PPC field location to NCA Crypt Specialist (in Spec 3.6.C) If Major crack repairs (ie..shoved lids) deemed necessary, see “Wall Repair Crypts 101” slides. Yet:

No repairs allowed on outside walls along PPC field edges.

No repairs allowed on walls bordering irrigation isle.

No wall repairs here

National Cemetery Administration

Shoved wall damage

Extra pics

Extra Pics

National Cemetery AdministrationDo not allow

City Cemetery across from Rhinelander Veterans Cemetery.

PPC Field Install Inspection & Protection� Crypts 101� PPC - PrePlaced Crypts � 6/29/2021 �
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10
Slide Number 11
Slide Number 12
Slide Number 13
Slide Number 14
Slide Number 15
Slide Number 16
Slide Number 17
Slide Number 18
Slide Number 19
Slide Number 20
Slide Number 21
Slide Number 22
Slide Number 23
Slide Number 24
Slide Number 25
Slide Number 26
Slide Number 27
Slide Number 28
Slide Number 29
Slide Number 30
Slide Number 31
Slide Number 32
Slide Number 33
Slide Number 34
Slide Number 35
Slide Number 36
Slide Number 37
Slide Number 38
Slide Number 39
Slide Number 40
Slide Number 41

File details come from the government source that posted it. Updated .