Drawings.pdf
PDF 8 MB Posted
- Solicitation number
- W912WJ22Q0155
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment W912WJ22Q0155-0002.pdf | ||
| Amendment W912WJ22Q0155-0001.pdf | ||
| Site Visit Map 1.pdf | ||
| Site Visit Map 2.pdf | ||
| Solicitation W912WJ22Q0155.pdf | ||
| Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL LEGEND
MECHANICAL DEMOLITION FLOOR PLAN I
MECHANICAL DEMOLITION FLOOR PLAN II
MECHANICAL FLOOR PLAN I
MECHANICAL FLOOR PLAN II
MECHANICAL TOWER SECTION DEMOLITION PLAN
MECHANICAL TOWER SECTION PLAN
MECHANICAL DETAILS I
MECHANICAL AIRFLOW DIAGRAM
MECHANICAL SCHEDULES
DESIGN FILESHEET NO.
G-001
INDEX TO DRAWINGS
SHEET TITLE
M-001
MD101
MD102
M-101
M-102
MD201
M-201
M-501
M-601
M-602
CON-CL-498_G-001.DWG COVER SHEET AND INDEX
CON-CL-498_M-001.DWG
CON-CL-498_MD-101.DWG
CON-CL-498_MD-102.DWG
CON-CL-498_M-101.DWG
CON-CL-498_M-102.DWG
CON-CL-498_MD-201.DWG
CON-CL-498_M-201.DWG
CON-CL-498_M-501.DWG
CON-CL-498_M-601.DWG
CON-CL-498_M-602.DWG
US Army Corps of Engineers
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
New England District
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL
OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET
APPROVED FOR TECHNICAL ADEQUACY BY:
TECHNICAL LEAD ENGINEER DATE
DATE
DATE
DATE
DATE
APPROVED BY:
APPROVAL RECOMMENDED BY:
CHIEF, ENGINEERING DIVISION
This project was designed by the U.S. Army Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents, within the scope of their employment as required by ER 1110-1-8152.
REVIEWED BY:
CHIEF, GEOTECHNICAL/WATER RESOURCES BRANCH
REVIEWED BY:
CHIEF, DESIGN BRANCH
CHIEF, GEO-ENVIRONMENTAL ENGINEERING BRANCH
GATEHOUSE HEATING SYSTEM REPLACEMENT
COLEBROOK RIVER LAKE
COLEBROOK, CONNECTICUT
W912WJ22Q0155
AUG 2022
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P S
O
F
E
N G
I N
E E
R S
N E
W
E
N G
L A
N D
I S
T R
I C
T
V
I R
G I N
A
R
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
I N
G
C
O D
E
C O
N T
R A
C T
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
E
L
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
N
C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
O F
MASSACHUSETTS
NEW
HAMPSHIRE
MAINE
VT.
CONN.
R.I.
HARTFORD
PROV.
C
A
P
E
COD
BOSTON
PORTSMOUTH
CONCORD
PORTLAND
AUGUSTA
BANGOR
N
ATLANTIC
OCEAN
CANADA
LOCATION MAP
NOT TO SCALE
VICINITY MAP
NOT TO SCALE
PROJECT
LOCATION
N
C
O
L
E
B
R
O
K
V
A
D
R
O
U
COLEBROOK
RIVER LAKE
COLEBROOK RIVER
LAKE DAM
COLEBROOK RIVER
LAKE GATEHOUSE
COLEBROOK RIVER LAKE GATEHOUSE
DESIGN FILESHEET NO.
INDEX OF RECORD DRAWINGS
SHEET TITLE
MECHANICAL - ARRANGEMENT OF EQUIPMENT PLANS AND DETAILS42 CON-16-42.TIF
OUTLET WORKS - INTAKE TOWERCON-16-43.TIF43
G-001
C O
V E
R
S
H E
D E
X
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
N
O
S
C A
L E
A U
G
VERTICAL TOWER SECTION STEEL REINFORCEMENTCON-16-31.TIF31
FLOOR PLANS ABOVE ELEVATION 657.0CON-16-17.TIF17
PLAN ELEVATION 631.0 SECTION AND DETAILSCON-16-15.TIF15
RECORD DRAWINGS PROVIDED TO CONTRACTOR FOR INFORMATION ONLY. CONTRACTOR SHALL FIELD VERIFY ALL
DIMENSIONS AS SHOWN. SEE SPECIFICATIONS FOR MORE INFORMATION.
James.M.Newman Text Box
JMN
E6CD9LAJ
Text Box 8/29/22
E6CD9LAJ
Text Box N/A
E6CD9LAJ
Text Box N/A
Matt Tessier Text Box 8/31/22
GENERAL MECHANICAL NOTES
1. LEGEND IS GENERAL IN NATURE AND MAY INDICATE MORE INFORMATION THAN IS
APPLICABLE TO PROJECT. SEE PLANS FOR SPECIFIC SYMBOLS AND ABBREVIATIONS.
2. PROVIDE ALL MATERIALS, VALVES, HANGERS, ETC. AND EQUIPMENT AND PERFORM ALL
LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE SYSTEMS AS INDICATED ON
THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODE.
3. INSTALL ALL EQUIPMENT, APPLIANCES, FIXTURES AND APPURTENANCES IN
ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, CONTRACT DOCUMENTS,
AND MOST STRINGENT APPLICABLE CODES AND REGULATIONS.
4. LOCATE ALL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS,
CONTROLS, AND VALVES.
5. VERIFY DIMENSIONS AND CONNECTION SIZE WITH FURNISHED EQUIPMENT AND EXISTING
TO REMAIN PIPING AND DUCTWORK.
6. ALL ELEVATIONS ARE ABOVE FINISHED FLOOR TO BOTTOM OF DUCT, PIPE, OR PIPE
INSULATION UNLESS NOTED OTHERWISE.
7. INSTALL TEMPERATURE CONTROLS AT 48" ABOVE FINISHED FLOOR AND COORDINATE
WITH OTHER DEVICES LOCATED ON WALLS.
8. MOUNT ALL OVERHEAD EQUIPMENT AND FIXTURES WEIGHING 31 POUNDS OR MORE TO
SUPPORTS THAT SHALL RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY
HORIZONTAL DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD
DIRECTION.
9. CONTRACTOR STAGING AND STORAGE AREA SHALL BE PROVIDED (APPROXIMATELY 2,500
SF). REFER TO THE ATTACHMENT AT THE END OF SPECIFICATION SECTION 01 50 00
TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS FOR MORE DETAIL. STAGING AND
STORAGE AREA SHALL BE LOCATED BETWEEN PARKING-AREA-DIVIDING LINE, MARKED
WHITE, AND TOWER ACCESS BRIDGE.
GENERAL DEMOLITION NOTES
1. DEMOLITION SHALL INCLUDE INSULATION, SUPPORTS, AND HANGERS ASSOCIATED WITH
DUCTWORK BEING REMOVED.
2. CUT, CAP, AND PROVIDE TEMPORARY PROTECTION FOR ALL UTILITIES EXISTING TO REMAIN
DURING CONSTRUCTION.
3. "XN" ADJACENT TO EQUIPMENT DENOTES EXISTING EQUIPMENT TO BE REMOVED AND
REPLACED WITH NEW.
GENERAL MECHANICAL ABBREVIATIONS
A/C AIR CONDITIONING
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AUTO AUTOMATIC
AVG AVERAGE
B BOILER
BBD BOILER BLOWDOWN
BF BOILER FEED, BACKFLOW
BHP BOILER HORSEPOWER, BRAKE HORSEPOWER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CAP CAPACITY
CW COLD WATER
CFM CUBIC FEET PER MINUTE
CO CLEAN OUT, CARBON MONOXIDE
CTE CONNECT TO EXISTING
DB DRY BULB {REFERENCE TO TEMPERATURE}
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG DRAWING
EA EACH, EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
ELEC ELECTRICAL
ENT ENTERING
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETR EXISTING TO REMAIN
EWT ENTERING WATER TEMPERATURE
EXST EXISTING
F FAHRENHEIT
FCO FLOOR CLEAN OUT
FLR FLOOR
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FEET, FOOT
FTR FIN TUBE RADIATION
G GAS, GRAM, GAS LINE
GAL GALLONS
GND GROUND
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H2O WATER
HB HOSE BIB (CONNECTION)
HD HEAD
HP HORSEPOWER, HIGH POINT
HR HOUR
HTG HEATING
HVAC HEATING VENTILATION AND AIR CONDITIONING
HW HOT WATER
HWR HOT WATER RETURN, HOT WATER RISER
HWS HOT WATER SUPPLY
HZ HERTZ (CYCLES PER SECOND)
IN INCHES
KW KILOWATT
L LENGTH, LITER
LAT LEAVING AIR TEMPERATURE
LB POUND
LP LOW POINT, LOW PRESSURE, PROPANE
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
M METER
MBH THOUSAND BRITISH THERMAL UNITS
PER HOUR
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM, MINUTE
MUA MAKE-UP AIR
NA NOT APPLICABLE
NTS NOT TO SCALE
OA OUTSIDE AIR
OAT OUTSIDE TEMPERATURE
OED OPEN ENDED DUCT
PD PRESSURE DROP
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH -GAUGE
QTY QUANTITY
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
REQ'D REQUIRED
REV REVISION
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
S SWITCH
SA SUPPLY AIR, SHOCK ABSORBER
SAT SUPPLY AIR TEMPERATURE
SENS SENSIBLE
SF SQUARE FEET, SERVICE FACTOR
SP STATIC PRESSURE
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
SUCT SUCTION
T THERMOSTAT
TBD TO BE DEMOLISHED
TEMP TEMPERATURE
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TYP TYPICAL
UH UNIT HEATER
V VOLTS, VENT, VOLUME
VTR VENT THROUGH ROOF
W WATT, WIDTH, WIDE
WB WET BULB TEMPERATURE
WC WATER COLUMN
WCO WALL CLEAN OUT
WH WATER HEATER
MECHANICAL SYMBOL LEGEND
T
THERMOSTAT
DEMOLITION SCOPE
MECHANICAL TAGS LEGEND
NON-POWERED EQUIPMENT TAG
EQUIPMENT TAG
NUMBER IDENTIFIER
12"x12" SA
DUCT SIZE
AIRFLOW TYPE
NEW WORK SCOPE SCOPE
EXISTING TO REMAIN SCOPE
HIDDEN SCOPE
CONNECT TO EXISTING
LIMIT DEMOLITION
S EMERGENCY SHUT-OFF SWITCH
SUPPLY
TAKE-0FF
VD
SQUARE ELBOW
RADIUS ELBOW
SUPPLY DUCT UP/DOWN
VD
VOLUME DAMPER
DUCTWORK SYMBOL LEGEND
X
X
NON-POWERED EQUIPMENT TAG
EQUIPMENT TAG
NUMBER IDENTIFIER
X
X
KEYNOTE TAG
JUNCTION BOX
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
M-001
M E
C H
A N
I C
A L
A B
B R
E V
I A
T I O
N S
L
E G
E N
D S
A
T
E S
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
N
O
S
C A
L E
A U
G
James.M.Newman
JMN
CHIMNEY ETR
20"x12" SA UP ETR
12"Ø SA
DOWN ETR
HATCH
FUEL
PUMP
ETR
FUEL
STORAGE
TANK ETR
30" AIR VENT
DOWN ETR. 30"
AIR VENT UP TO
INTAKE LOUVER
(TYP 3)
ELEVATOR
1/2" FUEL
OIL PIPE
OVERHEAD
ETR
B
D
ACCESS HATCH
S
ELECTRICAL POWER PANEL ETR
E
G
20"x12" SA
TBD
C
A
F
XN
XN
XN
H
12"Ø SA
UP ETR
12"x6" (2) SA TBD
12"x6" SA
TBD
12"x6"
SA TBD
12"x6" SA
DOWN
TBD
12"x6" SA
DOWN TBD
FLOOR
DRAIN
ETR
30"Ø AIR
VENT UP
ETR
GATE
CHAMBER
CYLINDER 1
GATE
CHAMBER
CYLINDER 2
GATE
CHAMBER
CYLINDER 3
30"Ø AIR
VENT UP
ETR
30"Ø AIR
VENT UP
ETR
GATE
CHAMBER
CYLINDER 4
GATE
CHAMBER
CYLINDER 5
GATE
CHAMBER
CYLINDER 6
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SCALE: 3/8" = 1'-0"
HEATER ROOM DEMOLITION FLOOR PLAN (EL. 777.0)
E9
MD101
M E
C H
A N
I C
M
O L
I T
I O
N
F L
O O
R
P
L A
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
A U
G
SCALE: 3/8" = 1'-0"
GATE CHAMBER DEMOLITION FLOOR PLAN (EL. 591.5)
E1
4'0 2' 8'4'0 2' 8'
NORTH
SHEET KEYNOTES
DEMOLISH WARM AIR FURNACE INCLUDING BLOWER MOTOR AND
ASSOCIATED DUCTWORK AND ACCESSORIES. DISCONNECT AND MAKE
SAFE ELECTRICAL UTILITY CONNECTION. LOCK-OUT-TAG-OUT ON
ASSOCIATED CIRCUIT BREAKERS DURING CONSTRUCTION. DEMOLISH
ASSOCIATED JUNCTION BOX. DISCONNECT FUEL OIL PIPING AND CAP
DURING CONSTRUCTION.
DEMOLISH EXISTING FURNACE FLUE VENT INCLUDING DUCTWORK,
SUPPORTS, CONNECTIONS, AND ALL ASSOCIATED ACCESSORIES.
DEMOLISH EXISTING SUPPLY AIR TERMINAL .
DEMOLISH EXISTING CENTRIFUGAL FAN INCLUDING STRUCTURAL
EQUIPMENT PAD, TRANSITION DUCTWORK, AND ASSOCIATED
ACCESSORIES. DISCONNECT AND MAKE SAFE ELECTRICAL UTILITY
CONNECTION AND DISCONNECT SWITCH CONNECTION.
LOCK-OUT-TAG-OUT ON ASSOCIATED CIRCUIT BREAKERS DURING
CONSTRUCTION. REFER TO M-501 FOR PAD DEMOLITION.
EXISTING ELECTRICAL CONDUIT DOWN TO GATE CHAMBER EXISTING TO
REMAIN.
EXISTING CENTRIFUGAL FAN DISCONNECT SWITCH AND EXISTING
JUNCTION BOX TO BE DEMOLISHED. REFER TO SHEET M-101 FOR NEW
WORK.
DEMOLISH EXISTING WARM AIR FURNACE EMERGENCY SHUT-OFF SWITCH
INCLUDING SWITCH BOX AND CONTROL WIRING BACK TO CEILING
MOUNTED CONDUIT BRANCH.
DEMOLISH COMBUSTION AIR INTAKE DUCTWORK UP TO OPERATING ROOM
ACCESS LADDER HATCH AND ALL ASSOCIATED ACCESSORIES AND
SUPPORTS.
A
B
1. UTILITIES SHALL BE DISCONNECTED IN ACCORDANCE WITH ALL
CODES DEFINED IN THESE CONTRACT DOCUMENTS. CONTRACTOR
SHALL VERIFY COMPLIANCE AND COR APPROVAL OF UTILITY
DISCONNECTIONS.
2. SCOPE OF DUCTWORK TO BE DEMOLISHED SHALL INCLUDE
FITTINGS, HANGERS, AND ASSOCIATED ACCESSORIES.
3. EXISTING TO REMAIN DUCTWORK SHALL BE CUT AND CAPPED
DURING CONSTRUCTION TO PREVENT DEBRIS ACCUMULATION.
4. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR
SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS
AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO
DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.
5. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.
6. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED
SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY
REQUIREMENTS.
7. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL
EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"
CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS
RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL
DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.
SHEET GENERAL NOTES
C
D
E
F
G
DEMOLISH EXISTING FAN,
CONCRETE PAD, AND DUCT
CONNECTION UP TO FLEXIBLE
DUCT CONNECTION
INCLUDING THE CONNECTOR.
ELECTRICAL
DISCONNECT
TO BE
DEMOLISHED
EXISTING CENTRIFUGAL FAN
H
James.M.Newman
14"x12" SA
TERMINAL ETR.
600 CFM
16"x8" SA UP ETR
20"x12" SA DOWN ETR
T
CHIMNEY ETR
ELEVATOR
ELECTRICAL PANEL, SUPPLIER
OF FAN AND WARM AIR
FURNACE, 'N2', ETR
GATE OPERATING
EQUIPMENT ETR
ACCESS HATCH
A
S
ACCESS
LADDER
HATCH
EXTERIOR
WALKWAY
MAIN ENTRY
DOOR
WARM AIR FURNACE
WALL SURFACE MOUNTED
EMERGENCY SHUT-OFF
SWITCH ETR
14"x12" SA
TERMINAL
ETR. 600
CFM
16"x8" SA
DOWN ETR
HATCH
CHIMNEY ETR
GENERATOR ASSEMBLY ETR
APPROXIMATE LOCATION
OF OVERHEAD CRANE
ACCESS
LADDER
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SCALE: 3/8" = 1'-0"
OPERATING ROOM DEMOLITION FLOOR PLAN (EL. 790.5)
E1
SCALE: 3/8" = 1'-0"
EQUIPMENT ROOM DEMOLITION FLOOR PLAN (EL. 804.5)
E11
MD102
M E
C H
A N
I C
M
O L
I T
I O
N
F L
O O
R
P
L A
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
A U
G
4'0 2' 8' 4'0 2' 8'
NORTH
SHEET KEYNOTES
DEMOLISH EXISTING WALL MOUNTED THERMOSTAT AND CONTROL WIRING.
IF UNIT CONTAINS MERCURY, CONTRACTOR SHALL CONFORM TO LOCAL
CODES AND REGULATION FOR SAFE DISPOSAL.
A
1. DUCTWORK TO BE DEMOLISHED SHALL INCLUDE FITTINGS,
HANGERS, AND ASSOCIATED ACCESSORIES.
2. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR
SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS
AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO
DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.
3. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.
4. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED
SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY
REQUIREMENTS.
5. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL
EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"
CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS
RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL
DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.
SHEET GENERAL NOTES
James.M.Newman
TERMINAL ETR.
600 CFM
14"x12" SA
TERMINAL ETR.
600 CFM
16"x8" SA
ETR
20"x12" SA
ETR
12"Ø SA
ETR
CHIMNEY ETR
EL. 804.5 EQUIPMENT ROOM
EL. 790.5 OPERATING ROOM
EL. 777.0 HEATER ROOM
LIMIT
DEMOLITION
A
C
20"x12" SA
TBD
T
30"Ø AIR
VENT ETR
B
D
XN
XN
E
EL. 816.0 ROOF LEVEL
A
A
B B
12"Ø SA
ETR
12"x6" SA
TBD
12"x6" SA
TBD
EL. 627.0
EL. 591.5 GATE CHAMBER
30"Ø AIR
VENT ETR
FLOOR
DRAIN ETR
B
B
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SCALE: 3/16" = 1'-0"
TOWER SECTION DEMOLITION PLAN B-B
A5
MD201
M E
C H
A N
I C
W
C
T I O
N
D E
M O
L I T
I O
N
P
L A
N
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
A U
G
8'0 4' 16'
KEY PLAN
NORTH
SHEET KEYNOTES
DEMOLISH WARM AIR FURNACE INCLUDING BLOWER MOTOR AND
ASSOCIATED DUCTWORK AND ACCESSORIES. DISCONNECT AND MAKE
SAFE ELECTRICAL UTILITY CONNECTION. LOCK-OUT-TAG-OUT ON
ASSOCIATED CIRCUIT BREAKERS DURING CONSTRUCTION. DEMOLISH
ASSOCIATED JUNCTION BOX. DISCONNECT FUEL OIL PIPING AFTER
DE-AERATOR AND CAP DURING CONSTRUCTION.
DEMOLISH EXISTING SUPPLY AIR TERMINAL .
DEMOLISH EXISTING CENTRIFUGAL FAN INCLUDING STRUCTURAL
EQUIPMENT PAD, TRANSITION DUCTWORK, AND ASSOCIATED
ACCESSORIES. DISCONNECT AND MAKE SAFE ELECTRICAL UTILITY
CONNECTION AND DEMOLISH DISCONNECT SWITCH. LOCK-OUT-TAG-OUT
ON ASSOCIATED CIRCUIT BREAKERS DURING CONSTRUCTION. DEMOLISH
ASSOCIATED JUNCTION BOX.
DEMOLISH EXISTING WALL MOUNTED WARM AIR FURNACE THERMOSTAT
AND CONTROL WIRING. IF UNIT CONTAINS MERCURY, CONTRACTOR SHALL
CONFORM TO LOCAL CODES AND REGULATION FOR SAFE DISPOSAL.
DEMOLISH COMBUSTION AIR INTAKE DUCTWORK UP TO OPERATING ROOM
ACCESS LADDER HATCH AND ALL ASSOCIATED ACCESSORIES AND
SUPPORTS.
A
B
1. UTILITIES SHALL BE DISCONNECTED IN ACCORDANCE WITH ALL
CODES DEFINED IN THESE CONTRACT DOCUMENTS. CONTRACTOR
SHALL VERIFY COMPLIANCE AND COR APPROVAL OF UTILITY
DISCONNECTIONS.
2. DUCTWORK TO BE DEMOLISHED SHALL INCLUDE FITTINGS,
HANGERS, AND ASSOCIATED ACCESSORIES.
3. EXISTING TO REMAIN DUCTWORK SHALL BE CUT AND CAPPED
DURING CONSTRUCTION TO PREVENT DEBRIS ACCUMULATION.
4. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR
SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS
AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO
DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.
5. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.
6. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED
SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY
REQUIREMENTS.
7. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL
EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"
CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS
RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL
DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.
SHEET GENERAL NOTES
C
D
SCALE: 3/16" = 1'-0"
TOWER SECTION DEMOLITION PLAN A-A
H5
8'0 4' 16'
EXISTING OIL FIRED WARM AIR FURNACE
EXISTING CENTRIFUGAL FAN
E
DEMOLISH EXISTING FAN,
CONCRETE PAD, AND DUCT
CONNECTION UP TO FLEXIBLE
DUCT CONNECTION INCLUDING
THE CONNECTOR.
ELECTRICAL
DISCONNECT
TO BE
DEMOLISHED
FUEL
OIL PIPE
ETR
COMBUSTION
AIR INTAKE
DUCTWORK
TO BE
DEMOLISHED
DE-AERATOR
ETR. CAP
FUEL OIL
PIPING
AFTER
DE-AERATOR.
James.M.Newman
CHIMNEY
20"x12" SA UP
12"Ø SA DOWN
EXISTING
FUEL
PUMP
EXISTING FUEL STORAGE TANKS
12"x6"
SA
30" AIR VENT
DOWN. 30" AIR
VENT UP TO
INTAKE LOUVER
(TYP 3)
EXISTING
1/2" FUEL
OIL PIPE
OVERHEAD
ACCESS HATCH
EXISTING ELECTRICAL POWER PANEL
ELEVATOR
20"x12"
SA
HATCH
S
VD
WARM AIR FURNACE
CONCENTRIC VENT UP
WAF
TF
SA
12"Ø SA UP
12"x12" SA
12"x6" SA
12"x6" SA
12"x6" SA
DOWN TO
SA-1 36"
AFF.
12"x6" SA DOWN
TO SA-1 36" AFF.
T
CTE
TO WAF-1
EXISTING
FLOOR
DRAIN
EXISTING
30"Ø AIR
VENT UP
GATE
CHAMBER
CYLINDER 1
GATE
CHAMBER
CYLINDER 2
GATE
CHAMBER
CYLINDER 3
EXISTING
30"Ø AIR
VENT UP
EXISTING
30"Ø AIR
VENT UP
GATE
CHAMBER
CYLINDER 4
GATE
CHAMBER
CYLINDER 5
GATE
CHAMBER
CYLINDER 6
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SCALE: 3/8" = 1'-0"
HEATER ROOM FLOOR PLAN (EL. 777.0)
E10
M-101
M E
C H
A N
I C
O O
R
P
L A
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
A U
G
SCALE: 3/8" = 1'-0"
GATE CHAMBER FLOOR PLAN (EL. 591.5)
E1
4'0 2' 8'4'0 2' 8'
NORTH
SHEET KEYNOTES
INSTALL NEW WALL MOUNTED WARM AIR FURNACE THERMOSTAT INCLUDING
WATER-TIGHT CONTROL BOX 48" AFF. INSTALL NEW LOW VOLTAGE WIRING TO
EXISTING CONDUIT/WIRING UP TO WAF-1.
INSTALL NEW DIRECT VENT WARM AIR FURNACE, WAF-1, ACCORDING TO
MANUFACTURER'S GUIDELINES INCLUDING BLOWER MOTOR, CONCENTRIC
VENT DUCTWORK, AND ASSOCIATED ACCESSORIES. RECONNECT FUEL OIL
PIPING, DE-AERATOR, AND ELECTRICAL THERMOSTAT CONNECTIONS. INSTALL
NEW JUNCTION BOX AND ASSOCIATED CONTROL WIRING. REROUTE EXISTING
ELECTRICAL WIRING TO REMAIN FROM 20A-1P CIRCUIT BREAKER IN
PANELBOARD 'N2' [CIRCUIT #23] VIA EXISTING EMERGENCY SHUT-OFF SWITCH
ON OPERATING ROOM FLOOR AND NEW FURNACE EMERGENCY SHUT-OFF
SWITCH LOCATION SHOWN TO WAF-1 INTEGRAL JUNCTION BOX. NEW WIRING
SHALL BE 2#12 AWG & 1#12AWG GND IN 3/4" RGS.
INSTALL CONCENTRIC DIRECT VENT WITHIN CHIMNEY UP TO OPERATING
ROOM AND THROUGH SIDEWALL PER MANUFACTURER'S GUIDELINES.
INSTALL NEW CENTRIFUGAL TRANSFER FAN, TF-1, ACCORDING TO
MANUFACTURER'S GUIDELINES INCLUDING VIBRATION ISOLATION
REQUIREMENTS. INSTALL NEW TRANSITION DUCTWORK FROM EXISTING 12"Ø
SA DUCT RISER TO OUTLET OF NEW CENTRIFUGAL FAN. WIRE NEW FAN AND
MOTOR STARTER VIA 3#12 AWG, 1#12 AWG GND IN 3/4" RGS FROM NEW
CENTRIFUGAL FAN DISCONNECT SWITCH.
INSTALL NEW LOW VOLTAGE WIRING TO THERMOSTAT IN GATE CHAMBER.
INSTALL ATTACHED TO EXISTING WIRING/CONDUIT.
12"x6" DOWN TO OED. TERMINATE WITH 1/2" WIREMESH BIRDSCREEN. REFER
TO DETAIL B1 ON M-501 FOR DUCT AND OUTLET ORIENTATION
RECONNECT EXISTING ELECTRICAL WIRING TO REMAIN FROM 15A-3P CIRCUIT
BREAKER IN PANELBOARD 'N2' [CIRCUIT #31, 33, 35] TO NEW 30A CENTRIFUGAL
FAN, F-1, DISCONNECT SWITCH. REFER TO ELECTRICAL PRODUCT
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
INSTALL NEW WALL MOUNTED WARM AIR FURNACE EMERGENCY SHUT OFF
SWITCH 48" AFF INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL
CONDUIT BACK TO WAF-1. RECONNECT TO EXISTING WIRING, WITHIN CEILING
MOUNTED CONDUIT, FROM EXISTING EMERGENCY SHUT OFF SWITCH IN
OPERATOR ROOM.
DUCTWORK SHALL BE CLEANED PER SPECIFICATION REQUIREMENTS
BEFORE NEW CONSTRUCTION WORK.
1. UTILITIES SHALL BE RECONNECTED IN ACCORDANCE WITH ALL
CODES DEFINED IN THESE CONTRACT DOCUMENTS. CONTRACTOR
SHALL VERIFY COMPLIANCE AND COR APPROVAL OF UTILITY
RECONNECTIONS PRIOR TO START UP OF ANY NEW
SYSTEMS/EQUIPMENT.
2. INSTALL NEW DUCTWORK, HANGERS, FITTINGS AND ACCESSORIES
IN ACCORDANCE WITH SPECIFICATIONS AND LOCAL CODES.
3. INSTALL ALL NEW DUCTWORK AND CONDUIT TIGHT TO
STRUCTURE.
4. REFER TO SPECIFICATIONS FOR DUCTWORK CLEANING
GUIDELINES.
5. DUCT ROUTING LOCATIONS AND EQUIPMENT LOCATIONS ARE
ESTIMATED AND SHALL BE FIELD VERIFIED.
6. CONTRACTOR TO REMOVE COVER, CLEAN, AND CLEAR FLOOR
DRAIN IN GATE CHAMBER.
7. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR
SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS
AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO
DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.
8. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.
9. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED
SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY
REQUIREMENTS.
10. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL
EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"
CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS
RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL
DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.
SHEET GENERAL NOTES
AutoCAD SHX Text J
James.M.Newman
EXISTING
TERMINAL.
500 CFM
EXISTING CHIMNEY
16"x8" SA UP
20"x12" SA DOWN
HATCH
T
ELECTRICAL PANEL ETR
GATE OPERATING
EQUIPMENT
ACCESS HATCH
ELEVATOR
S
ACCESS
LADDER
WARM AIR FURNACE WALL
SURFACE MOUNTED EMERGENCY
SHUT-OFF SWITCH
EXISTING
14"x12" SA
TERMINAL.
500 CFM
EXISTING CHIMNEY
16"x8" SA
DOWN
HATCH
GENERATOR ASSEMBLY
APPROXIMATE LOCATION
OF OVERHEAD CRANE
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SCALE: 3/8" = 1'-0"
OPERATING ROOM FLOOR PLAN (EL. 790.5)
E1
SCALE: 3/8" = 1'-0"
EQUIPMENT ROOM FLOOR PLAN (EL. 804.5)
E11
M-102
M E
C H
A N
I C
A L
F L
O O
R
P
L A
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
A U
G
4'0 2' 8' 4'0 2' 8'
NORTH
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
SHEET KEYNOTES
INSTALL NEW WALL SURFACE MOUNTED WARM AIR FURNACE THERMOSTAT
48" AFF INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL, METAL,
SURFACE MOUNTED CONDUIT BACK TO WAF-1.
DUCTWORK AND AIR TERMINALS SHALL BE CLEANED BEFORE NEW
CONSTRUCTION WORK.
INSTALL CONCENTRIC DIRECT VENT THROUGH SIDEWALL PER
MANUFACTURER'S GUIDELINES. VENT SIZING SHALL BE PER
MANUFACTURER'S REQUIREMENTS. PRIOR TO CORING HOLE FOR NEW VENT,
CONTRACTOR SHALL LOCATE EXISTING STEEL REINFORCING BARS TO MAKE
CERTAIN VENT WILL NOT INTERFERE WITH EXISTING STEEL REINFORCEMENT
AS SHOWN ON RECORD DRAWING CON-16-31. CORE FLUE PENETRATION
SIZED TO MANUFACTURER'S INSTALLATION REQUIREMENTS. PROVIDE STEEL
BRACING AND CAST CONCRETE FILL TO MAINTAIN STRUCTURAL INTEGRITY.
INSTALL AIRTIGHT CHIMNEY ACCESS PANEL AS REQUIRE TO ASSIST IN FLUE
INSTALLATION. ENGAGE THE SERVICE OF A PROFESSIONAL ENGINEER
LICENSED IN THE STATE OF CONNECTICUT TO REINFORCE NEW OPENING AS
REQUIRED. SUBMIT DETAILS OF NEW OPENING, AIRTIGHT PANEL, AND
REINFORCING
1. INSTALL ALL NEW CONDUIT TIGHT TO STRUCTURE.
2. REFER TO SPECIFICATIONS FOR DUCTWORK CLEANING
GUIDELINES.
3. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR
SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS
AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO
DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.
4. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.
5. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED
SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY
REQUIREMENTS.
6. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL
EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"
CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS
RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL
DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.
SHEET GENERAL NOTES
WARM AIR FURNACE
CONCENTRIC VENT
DOWN
James.M.Newman
TERMINAL.
600 CFM
14"x12" SA
TERMINAL.
600 CFM
16"x8" SA
20"x12" SA
12"Ø SA
EXISTING
CHIMNEY
EL. 804.5 EQUIPMENT ROOM
EL. 790.5 OPERATING ROOM
EL. 777.0 HEATER ROOM
12"x6"
SA
S
T
VD
EL. 816.0 ROOF LEVEL
WAF
TF
SA
A
A
B B
12"Ø SA
12"x6" SA
12"x6" SA
SA-1
TERMINATE
36" AFF.
SA-1
TERMINATE
36" AFF. 500
CFM
EL. 627.0
EL. 591.5 GATE CHAMBER
30"Ø AIR
VENT
EXISTING
FLOOR
DRAIN
T
SA
SA
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
J
K
L
M
N
P
M-201
M E
C H
A N
I C
W
E R
S E
C T
I O
N
P
L A
N
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
A U
G
8'0 4' 16'
SCALE: 3/16" = 1'-0"
TOWER SECTION PLAN B-B
A5
KEY PLAN
NORTH
SHEET KEYNOTES
INSTALL NEW WARM AIR FURNACE, WAF-1, ACCORDING TO MANUFACTURER'S
GUIDELINES INCLUDING BLOWER MOTOR, CONCENTRIC VENT DUCTWORK,
AND ASSOCIATED ACCESSORIES. INSTALL CONCENTRIC VENT THROUGH
EXISTING CHIMNEY. RECONNECT FUEL OIL PIPING, DE-AERATOR, AND
ELECTRICAL UTILITY CONNECTIONS.
INSTALL NEW CENTRIFUGAL FAN, TF-1, ACCORDING TO MANUFACTURER'S
GUIDELINES INCLUDING VIBRATION ISOLATION REQUIREMENTS, AND
ASSOCIATED ACCESSORIES. RECONNECT ELECTRICAL UTILITY AND EXISTING
FAN DISCONNECT CONNECTIONS. INSTALL NEW TRANSITION DUCTWORK
FROM EXISTING 12"Ø SA DUCT RISER TO OUTLET OF NEW CENTRIFUGAL FAN.
INSTALL NEW WALL MOUNTED WARM AIR FURNACE THERMOSTAT 48" AFF
INCLUDING WATER-TIGHT CONTROL BOX TO PERIMETER WALL. INSTALL NEW
LOW VOLTAGE WIRING TO EXISTING CONDUIT/CABLES UP TO WAF-1. NOTE:
THERMOSTAT SHOWN OF WALL FOR DIAGRAMMATIC PURPOSES ONLY. REFER
TO SHEET M-101 FOR WALL LOCATION.
INSTALL NEW WALL MOUNTED WARM AIR FURNACE EMERGENCY SHUT OFF
SWITCH 48" AFF INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL
CONDUIT BACK TO WAF-1. REFER TO SHEET M-101 FOR WALL LOCATION.
INSTALL NEW WALL MOUNTED WARM AIR FURNACE THERMOSTAT 48" AFF
INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL CONDUIT BACK TO
WAF-1. REFER TO SHEET M-102 FOR WALL LOCATION.
12"x6" OED. TERMINATE WITH 1/2" WIREMESH BIRDSCREEN. REFER TO DETAIL
B1 ON M-501 FOR DUCT AND OUTLET ORIENTATION.
DUCTWORK AND AIR TERMINALS SHALL BE CLEANED BEFORE NEW
CONSTRUCTION WORK.
INSTALL AIRTIGHT CHIMNEY ACCESS PANEL AS REQUIRE TO ASSIST IN FLUE
INSTALLATION. ENGAGE THE SERVICE OF A PROFESSIONAL ENGINEER
LICENSED IN THE STATE OF CONNECTICUT TO REINFORCE NEW OPENING AS
REQUIRED. SUBMIT DETAILS OF NEW OPENING, AIRTIGHT PANEL, AND
REINFORCING.
1. UTILITIES SHALL BE RECONNECTED IN ACCORDANCE WITH
NATIONAL AND LOCAL CODES DEFINED IN THE SCOPE OF WORK.
CONTRACTOR SHALL VERIFY COMPLIANCE OF INSTALLATION
BEFORE SYSTEM FILL AND START UP.
2. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR
SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS
AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO
DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.
3. INSTALL NEW DUCTWORK, HANGERS, FITTINGS AND ACCESSORIES
IN ACCORDANCE WITH SPECIFICATIONS AND APPLICABLE LOCAL
CODES.
4. REFER TO SPECIFICATIONS FOR DUCTWORK CLEANING
GUIDELINES.
5. CONTRACTOR TO REMOVE COVER, CLEAN, AND CLEAR FLOOR
DRAIN IN GATE CHAMBER.
6. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.
7. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED
SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY
REQUIREMENTS.
8. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL
EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"
CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS
RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL
DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.
SHEET GENERAL NOTES
8'0 4' 16'
SCALE: 3/16" = 1'-0"
TOWER SECTION PLAN A-A
H5
James.M.Newman
1/2" FUEL OIL PIPE CTE
W
L
L=W/4 (4" MIN.)
L
W
45°
MAIN DUCT
45°
RECTANGULAR
BRANCH DUCT
ROUND
FLEXIBLE DUCT
CONNECTION
SUPPLY AIR
DUCTWORK
BLOWER
AND
MOTOR
OIL SHUT OFF
OIL FILTER
CONCENTRIC
DIRECT
VENT KIT
METAL SURFACE
MOUNTED
CONTROL WIRE
CONDUIT.
THERMOSTAT
WITH 1/4"
INSULATING
BASE
ELECTRICAL
JUNCTION BOX
SECURE TO WALL
W/(4) SCREW
ANCHORS.
1" PVC STAND-OFF
FLEXIBLE CONNECTION
TRANSITION (AS REQUIRED)
FAN INLET PROVIDE FLEXIBLE
CONNECTION AND INLET
SCREEN.
WEATHER PROOF MOTOR
HOUSING SHALL HAVE
REMOVABLE PANELS FOR
ACCESS TO MOTOR AND
DRIVE
W = SEE PLANS
FAN SUPPORT PER
MANUFACTURER'S
GUIDELINES. INSTALL WITH
VIBRATION ISOLATION.
FLOOR
WAF-1
TF-1
WAF-1
A
B
SUPPLY AIR
DUCTWORK
SUPPLY AIR
DUCTWORK
A = DISTANCE FROM OED TO
CENTRIFUGAL FAN INTAKE: 6-12"
B = DISTANCE OED TO CENTRIFUGAL
FAN INTAKE: CONSTRUCT AS
NECESSARY TO ALIGN WITH
CENTRIFUGAL FAN INTAKE
CENTER
OED DUCT
TERMINATED W/
WIREMESH
BIRDSCREEN
EXISTING CHIMNEY
SUPPLY AIR
DUCTWORK
FLEXIBLE DUCT
CONNECTION
RAIN CAP
FRONT VIEW
SIDE VIEW
EXTERIOR
WALL
RETURN AIR
VD
OPERATING ROOM
EXTERIOR
WALKWAY
METAL SURFACE
MOUNTED
CONTROL WIRE
CONDUIT.
EMERGENCY SHUT OFF
SWITCH BOX. SECURE TO
WALL W/(4) SCREW
ANCHORS.
1" PVC STAND-OFF
METAL SURFACE MOUNTED
CONTROL WIRE CONDUIT.
THERMOSTAT
WITH 1/4"
INSULATING
BASE
ELECTRICAL JUNCTION
BOX SECURE TO WALL
W/(4) SCREW ANCHORS.
1" PVC STAND-OFF
EMERGENCY FURNACE SHUT OFF SWITCH
WALL MOUNTED THERMOSTAT
WEATHERPROOF WALL MOUNTED
THERMOSTAT
COVER HINGE
WEATHERPROOF COVER
GALVANIZED
ANCHOR SCREW
(TYP)
1-1/4 X 1-1/4 X
3/16 ANGLE
IRON
SUPPORTS.
GALVANIZED,
ADJUSTABLE
VERTICAL DUCT
SUPPORT
BRACKET
VERTICAL
DUCTWORK.
SEE PLANS FOR
DIMENSIONS.
WALL
INSTALL AIRTIGHT CHIMNEY ACCESS
PANEL AS REQUIRE TO ASSIST IN FLUE
INSTALLATION. ENGAGE THE SERVICE OF
A PROFESSIONAL ENGINEER LICENSED IN
THE STATE OF CONNECTICUT TO
REINFORCE NEW OPENING AS
REQUIRED. SUBMIT DETAILS OF NEW
OPENING, AIRTIGHT PANEL, AND
REINFORCING.
EXISTING
ACCESS
PANEL TO BE
USED FOR
INSTALLATION
GALVANIZED
ANCHOR SCREW
(TYP)
1-1/4 X 1-1/4 X
3/16 ANGLE
IRON
SUPPORTS.
GALVANIZED,
ADJUSTABLE
DUCT STRAP
SUPPORT
BRACKET
HORIZONTAL
DUCTWORK.
SEE PLANS FOR
DIMENSIONS.
CONCRETE DECK
EXISTING CONCRETE
FLUSH FLUSH W/
REPAIR MORTAR
ROUGHEN SURFACE
TO ICRI CSP 5
ROUGHEN SURFACE
TO ICRI CSP 5
REMOVE EXISTING
CONCRETE DOWN
TO 2" BELOW TOP OF
EXISTING SLAB.
1" SAW CUT ALL
AROUND
1" (TYP)
CUT EXISTING DOWELS 1"
FROM FACE
EXISTING CONCRETE PAD TO
BE REMOVED
FAN INTAKE
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
M-501
M E
C H
A N
I C
T
A I L
S
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
N
O
S
C A
L E
A U
G
SCALE: NOT TO SCALE
TYPICAL BRANCH CONNECTION DETAIL
L1
SCALE: NOT TO SCALE
CENTRIFUGAL FAN DETAIL
L7
SCALE: NOT TO SCALE
DUCT STRAP HANGER DETAIL
L13
SCALE: NOT TO SCALE
FUEL OIL-FIRED WARM AIR FURNACE, CENTRIFUGAL FAN, AND CONCENTRIC VENT DETAIL
B1
SCALE: NOT TO SCALE
VERITCAL DUCT SUPPORT DETAIL
G13
SCALE: NOT TO SCALE
WALL MOUNTED THERMOSTAT/SWTICH DETAIL
B13
SCALE: NOT TO SCALE
CONCRETE PAD DEMOLITION DETAIL
G1
James.M.Newman
SEQUENCE OF OPERATIONS:
HEATING OPERATION:
1. THE WARM AIR FURNACE SHALL RELY ON A CALL FOR
HEAT FROM EITHER OF THE TWO (2) THERMOSTATS
LOCATED IN THE OPERATING ROOM AND GATE
CHAMBER.
2. THE BURNER AND BLOWER SHALL BE ENGAGED WHEN
EITHER OF THE TWO THERMOSTATS SENSES A
TEMPERATURE BELOW 55°F (ADJ.).
3. THE WARM AIR FURNACE SHALL RUN UNTIL BOTH
THERMOSTATS HAVE REACHED THEIR SETPOINTS AT
WHICH TIME THE BURNER AND BLOWER SHALL
SHUTDOWN AND REMAIN OFF UNTIL A THERMOSTAT
CALLS FOR HEAT.
INLINE FAN SEQUENCE OF OPERATION:
1. THE FAN SHALL OPERATE UNLESS MANUALLY SWITCHED
OFF.
WAF-1
F-1
T
T
EQUIPMENT ROOM
OPERATING ROOM
HEATER ROOM
GATE CHAMBER ROOM
TOWER
HATCH OPENING
HATCH OPENING
HATCH OPENING
HATCH OPENING
RA
RA
RA
RA
500 CFM
500 CFM
500 CFM
500 CFM
500 CFM 500 CFM
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
N
P
M-601
M E
C H
A N
I C
N
T R
A
G R
A
D
S
E Q
U E
N C
E
O
F
O
P E
R A
T I O
N S
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
N
O
S
C A
L E
A U
G
James.M.Newman
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
H
E A
T I N
G
S
Y S
T E
M
R
E P
L A
C E
M E
N T
C O
L E
B R
O O
K
R
I V
K E
C O
L E
B R
O O
K
C
O N
N E
C T
I C
U T
W W
J Q
C O
N C
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
M-602
M E
C H
A N
I C
H
E D
U L
E
M
C
R A
I G
M
C
R A
I G
J
N
E W
M A
N
J
N
E W
M A
N
A N
S I
D
N
O
S
C A
L E
A U
G
UNIT
TAG
DIFFUSER/REGISTER/GRILLE SCHEDULE
MAX PRESSURE
DROP
(IN WC)
.06
CFM
RANGE
SIZE (IN)
NOTES
NOTES:
1. ALUMINUM CONSTRUCTION
2. DUCT MOUNTED
0-500
12X12 SUPPLY
TYPE
OPPOSED BLADE SIDEWALL
.06 0-500
14X24 SUPPLY
OPPOSED BLADE SIDEWALL 1, 2
TYPE
UNIT TAG
MINIMUM
AIRFLOW
NOTES
WARM AIR FURNACE SCHEDULE
NOTES:
1. INSTALL PER MANUFACTURER'S GUIDELINES. PROVIDE WITH DIRECT CONCENTRIC VENT KIT, BLOWER MOTOR, BURNER, SPARE FILTER SET, OIL FILTER, OIL SHUT OFF VALVE, AND REMOTE EMERGENCY SHUT OFF
SWITCH.
2. FURNACE SHALL BE HIGH EFFICIENCY AND NON-CONDENSING.
MINIMUM
INPUT
(MBH)
MINIMUM
OUTPUT
(MBH)
MINIMUM
COMBUSTION
EFFICIENCY
MINIMUM
VENT
CONNECTION
(IN)
ELECTRICAL DATA
(VOLTS/PHASE/HERTZ)
OIL FIRED 2000 CFM245 205 83.7 6 120/1/60 1, 2
UNIT
TAG
CENTRIFUGAL TRANSFER FAN SHEDULE
MINIMUM
AIRFLOW
1000 CFM
STATIC
PRESSURE
DROP (IN
WC)
MINIMUM
MOTOR HP
NOTES
NOTES:
1. INSTALL PER MANUFACTURER'S GUIDELINES. PROVIDE WITH FLOOR MOUNTING FRAME WITH VIBRATION ISOLATION, DISCONNECT SWITCH
CONNECTION, INTAKE SCREEN, AND MOTOR ENCLOSURE. FAN SHALL BE DIRECT DRIVE.
3/4
TYPE
UTILITY SET 1
ELECTRICAL
DATA
(VOLTS/PHASE/HERTZ)
208-230/3/60
TF-1
SA-1
SA-2
WAF-1
MINIMUM
BLOWER
MOTOR
HP
FACTORY EQUIPPED BLOWER POWER REQUIREMENTS
1/3 & 1/2
(AMPS)
12 15 20
3/4 HP BELT DRIVE AND 1
HP DIRECT DRIVE
1 HP BELT
DRIVE
James.M.Newman
| Sheets and Views |
| CON-CL-498_G-001-ANSI 'D' |
| CON-CL-498_M-001-M-001 |
| CON-CL-498_MD101-MD-101 |
| CON-CL-498_MD102-MD-102 |
| CON-CL-498_MD201-MD201 |
| CON-CL-498_M-101-M-101 |
| CON-CL-498_M-102-M-102 |
| CON-CL-498_M-201-M-201 |
| CON-CL-498_M-501-M-501 |
| CON-CL-498_M-601-M-601 |
| CON-CL-498_M-602-M-602 |
| 2022-08-31T10:39:59-0400 | |
| JACOBS.LAUREN.ASHLEY.1137790927 |
| 2022-08-31T11:00:02-0400 | |
| TESSIER.MATTHEW.E.1377053253 | |
| I am approving this document |
| 2022-08-31T16:05:51-0400 | |
| MARGOLIS.DAVID.I.1228573805 |
File details come from the government source that posted it. Updated .