MECHANICAL LEGEND

MECHANICAL DEMOLITION FLOOR PLAN I

MECHANICAL DEMOLITION FLOOR PLAN II

MECHANICAL FLOOR PLAN I

MECHANICAL FLOOR PLAN II

MECHANICAL TOWER SECTION DEMOLITION PLAN

MECHANICAL TOWER SECTION PLAN

MECHANICAL DETAILS I

MECHANICAL AIRFLOW DIAGRAM

MECHANICAL SCHEDULES

DESIGN FILESHEET NO.

G-001

INDEX TO DRAWINGS

SHEET TITLE

M-001

MD101

MD102

M-101

M-102

MD201

M-201

M-501

M-601

M-602

CON-CL-498_G-001.DWG COVER SHEET AND INDEX

CON-CL-498_M-001.DWG

CON-CL-498_MD-101.DWG

CON-CL-498_MD-102.DWG

CON-CL-498_M-101.DWG

CON-CL-498_M-102.DWG

CON-CL-498_MD-201.DWG

CON-CL-498_M-201.DWG

CON-CL-498_M-501.DWG

CON-CL-498_M-601.DWG

CON-CL-498_M-602.DWG

US Army Corps of Engineers

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

New England District

SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL

OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET

APPROVED FOR TECHNICAL ADEQUACY BY:

TECHNICAL LEAD ENGINEER DATE

DATE

DATE

DATE

DATE

APPROVED BY:

APPROVAL RECOMMENDED BY:

CHIEF, ENGINEERING DIVISION

This project was designed by the U.S. Army Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents, within the scope of their employment as required by ER 1110-1-8152.

REVIEWED BY:

CHIEF, GEOTECHNICAL/WATER RESOURCES BRANCH

REVIEWED BY:

CHIEF, DESIGN BRANCH

CHIEF, GEO-ENVIRONMENTAL ENGINEERING BRANCH

GATEHOUSE HEATING SYSTEM REPLACEMENT

COLEBROOK RIVER LAKE

COLEBROOK, CONNECTICUT

W912WJ22Q0155

AUG 2022

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P S

O

F

E

N G

I N

E E

R S

N E

W

E

N G

L A

N D

I S

T R

I C

T

V

I R

G I N

A

R

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

I N

G

C

O D

E

C O

N T

R A

C T

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

E

L

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

N

C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

O F

MASSACHUSETTS

NEW

HAMPSHIRE

MAINE

VT.

CONN.

R.I.

HARTFORD

PROV.

C

A

P

E

COD

BOSTON

PORTSMOUTH

CONCORD

PORTLAND

AUGUSTA

BANGOR

N

ATLANTIC

OCEAN

CANADA

LOCATION MAP

NOT TO SCALE

VICINITY MAP

NOT TO SCALE

PROJECT

LOCATION

N

C

O

L

E

B

R

O

K

V

A

D

R

O

U

COLEBROOK

RIVER LAKE

COLEBROOK RIVER

LAKE DAM

COLEBROOK RIVER

LAKE GATEHOUSE

COLEBROOK RIVER LAKE GATEHOUSE

DESIGN FILESHEET NO.

INDEX OF RECORD DRAWINGS

SHEET TITLE

MECHANICAL - ARRANGEMENT OF EQUIPMENT PLANS AND DETAILS42 CON-16-42.TIF

OUTLET WORKS - INTAKE TOWERCON-16-43.TIF43

G-001

C O

V E

R

S

H E

D E

X

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

N

O

S

C A

L E

A U

G

VERTICAL TOWER SECTION STEEL REINFORCEMENTCON-16-31.TIF31

FLOOR PLANS ABOVE ELEVATION 657.0CON-16-17.TIF17

PLAN ELEVATION 631.0 SECTION AND DETAILSCON-16-15.TIF15

RECORD DRAWINGS PROVIDED TO CONTRACTOR FOR INFORMATION ONLY. CONTRACTOR SHALL FIELD VERIFY ALL

DIMENSIONS AS SHOWN. SEE SPECIFICATIONS FOR MORE INFORMATION.

James.M.Newman Text Box

JMN

E6CD9LAJ

Text Box 8/29/22

E6CD9LAJ

Text Box N/A

E6CD9LAJ

Text Box N/A

Matt Tessier Text Box 8/31/22

GENERAL MECHANICAL NOTES

1. LEGEND IS GENERAL IN NATURE AND MAY INDICATE MORE INFORMATION THAN IS

APPLICABLE TO PROJECT. SEE PLANS FOR SPECIFIC SYMBOLS AND ABBREVIATIONS.

2. PROVIDE ALL MATERIALS, VALVES, HANGERS, ETC. AND EQUIPMENT AND PERFORM ALL

LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE SYSTEMS AS INDICATED ON

THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODE.

3. INSTALL ALL EQUIPMENT, APPLIANCES, FIXTURES AND APPURTENANCES IN

ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, CONTRACT DOCUMENTS,

AND MOST STRINGENT APPLICABLE CODES AND REGULATIONS.

4. LOCATE ALL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS,

CONTROLS, AND VALVES.

5. VERIFY DIMENSIONS AND CONNECTION SIZE WITH FURNISHED EQUIPMENT AND EXISTING

TO REMAIN PIPING AND DUCTWORK.

6. ALL ELEVATIONS ARE ABOVE FINISHED FLOOR TO BOTTOM OF DUCT, PIPE, OR PIPE

INSULATION UNLESS NOTED OTHERWISE.

7. INSTALL TEMPERATURE CONTROLS AT 48" ABOVE FINISHED FLOOR AND COORDINATE

WITH OTHER DEVICES LOCATED ON WALLS.

8. MOUNT ALL OVERHEAD EQUIPMENT AND FIXTURES WEIGHING 31 POUNDS OR MORE TO

SUPPORTS THAT SHALL RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY

HORIZONTAL DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD

DIRECTION.

9. CONTRACTOR STAGING AND STORAGE AREA SHALL BE PROVIDED (APPROXIMATELY 2,500

SF). REFER TO THE ATTACHMENT AT THE END OF SPECIFICATION SECTION 01 50 00

TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS FOR MORE DETAIL. STAGING AND

STORAGE AREA SHALL BE LOCATED BETWEEN PARKING-AREA-DIVIDING LINE, MARKED

WHITE, AND TOWER ACCESS BRIDGE.

GENERAL DEMOLITION NOTES

1. DEMOLITION SHALL INCLUDE INSULATION, SUPPORTS, AND HANGERS ASSOCIATED WITH

DUCTWORK BEING REMOVED.

2. CUT, CAP, AND PROVIDE TEMPORARY PROTECTION FOR ALL UTILITIES EXISTING TO REMAIN

DURING CONSTRUCTION.

3. "XN" ADJACENT TO EQUIPMENT DENOTES EXISTING EQUIPMENT TO BE REMOVED AND

REPLACED WITH NEW.

GENERAL MECHANICAL ABBREVIATIONS

A/C AIR CONDITIONING

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AUTO AUTOMATIC

AVG AVERAGE

B BOILER

BBD BOILER BLOWDOWN

BF BOILER FEED, BACKFLOW

BHP BOILER HORSEPOWER, BRAKE HORSEPOWER

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

CAP CAPACITY

CW COLD WATER

CFM CUBIC FEET PER MINUTE

CO CLEAN OUT, CARBON MONOXIDE

CTE CONNECT TO EXISTING

DB DRY BULB {REFERENCE TO TEMPERATURE}

DEG DEGREE

DIA DIAMETER

DN DOWN

DWG DRAWING

EA EACH, EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

ELEC ELECTRICAL

ENT ENTERING

ESP EXTERNAL STATIC PRESSURE

ET EXPANSION TANK

ETR EXISTING TO REMAIN

EWT ENTERING WATER TEMPERATURE

EXST EXISTING

F FAHRENHEIT

FCO FLOOR CLEAN OUT

FLR FLOOR

FPM FEET PER MINUTE

FPS FEET PER SECOND

FT FEET, FOOT

FTR FIN TUBE RADIATION

G GAS, GRAM, GAS LINE

GAL GALLONS

GND GROUND

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

H2O WATER

HB HOSE BIB (CONNECTION)

HD HEAD

HP HORSEPOWER, HIGH POINT

HR HOUR

HTG HEATING

HVAC HEATING VENTILATION AND AIR CONDITIONING

HW HOT WATER

HWR HOT WATER RETURN, HOT WATER RISER

HWS HOT WATER SUPPLY

HZ HERTZ (CYCLES PER SECOND)

IN INCHES

KW KILOWATT

L LENGTH, LITER

LAT LEAVING AIR TEMPERATURE

LB POUND

LP LOW POINT, LOW PRESSURE, PROPANE

LVG LEAVING

LWT LEAVING WATER TEMPERATURE

M METER

MBH THOUSAND BRITISH THERMAL UNITS

PER HOUR

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM, MINUTE

MUA MAKE-UP AIR

NA NOT APPLICABLE

NTS NOT TO SCALE

OA OUTSIDE AIR

OAT OUTSIDE TEMPERATURE

OED OPEN ENDED DUCT

PD PRESSURE DROP

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH -GAUGE

QTY QUANTITY

RA RETURN AIR

RAT RETURN AIR TEMPERATURE

REQ'D REQUIRED

REV REVISION

RH RELATIVE HUMIDITY

RL REFRIGERANT LIQUID

RS REFRIGERANT SUCTION

S SWITCH

SA SUPPLY AIR, SHOCK ABSORBER

SAT SUPPLY AIR TEMPERATURE

SENS SENSIBLE

SF SQUARE FEET, SERVICE FACTOR

SP STATIC PRESSURE

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

SUCT SUCTION

T THERMOSTAT

TBD TO BE DEMOLISHED

TEMP TEMPERATURE

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

TYP TYPICAL

UH UNIT HEATER

V VOLTS, VENT, VOLUME

VTR VENT THROUGH ROOF

W WATT, WIDTH, WIDE

WB WET BULB TEMPERATURE

WC WATER COLUMN

WCO WALL CLEAN OUT

WH WATER HEATER

MECHANICAL SYMBOL LEGEND

T

THERMOSTAT

DEMOLITION SCOPE

MECHANICAL TAGS LEGEND

NON-POWERED EQUIPMENT TAG

EQUIPMENT TAG

NUMBER IDENTIFIER

12"x12" SA

DUCT SIZE

AIRFLOW TYPE

NEW WORK SCOPE SCOPE

EXISTING TO REMAIN SCOPE

HIDDEN SCOPE

CONNECT TO EXISTING

LIMIT DEMOLITION

S EMERGENCY SHUT-OFF SWITCH

SUPPLY

TAKE-0FF

VD

SQUARE ELBOW

RADIUS ELBOW

SUPPLY DUCT UP/DOWN

VD

VOLUME DAMPER

DUCTWORK SYMBOL LEGEND

X

X

NON-POWERED EQUIPMENT TAG

EQUIPMENT TAG

NUMBER IDENTIFIER

X

X

KEYNOTE TAG

JUNCTION BOX

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

M-001

M E

C H

A N

I C

A L

A B

B R

E V

I A

T I O

N S

L

E G

E N

D S

A

T

E S

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

N

O

S

C A

L E

A U

G

James.M.Newman

JMN

CHIMNEY ETR

20"x12" SA UP ETR

12"Ø SA

DOWN ETR

HATCH

FUEL

PUMP

ETR

FUEL

STORAGE

TANK ETR

30" AIR VENT

DOWN ETR. 30"

AIR VENT UP TO

INTAKE LOUVER

(TYP 3)

ELEVATOR

1/2" FUEL

OIL PIPE

OVERHEAD

ETR

B

D

ACCESS HATCH

S

ELECTRICAL POWER PANEL ETR

E

G

20"x12" SA

TBD

C

A

F

XN

XN

XN

H

12"Ø SA

UP ETR

12"x6" (2) SA TBD

12"x6" SA

TBD

12"x6"

SA TBD

12"x6" SA

DOWN

TBD

12"x6" SA

DOWN TBD

FLOOR

DRAIN

ETR

30"Ø AIR

VENT UP

ETR

GATE

CHAMBER

CYLINDER 1

GATE

CHAMBER

CYLINDER 2

GATE

CHAMBER

CYLINDER 3

30"Ø AIR

VENT UP

ETR

30"Ø AIR

VENT UP

ETR

GATE

CHAMBER

CYLINDER 4

GATE

CHAMBER

CYLINDER 5

GATE

CHAMBER

CYLINDER 6

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SCALE: 3/8" = 1'-0"

HEATER ROOM DEMOLITION FLOOR PLAN (EL. 777.0)

E9

MD101

M E

C H

A N

I C

M

O L

I T

I O

N

F L

O O

R

P

L A

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

A U

G

SCALE: 3/8" = 1'-0"

GATE CHAMBER DEMOLITION FLOOR PLAN (EL. 591.5)

E1

4'0 2' 8'4'0 2' 8'

NORTH

SHEET KEYNOTES

DEMOLISH WARM AIR FURNACE INCLUDING BLOWER MOTOR AND

ASSOCIATED DUCTWORK AND ACCESSORIES. DISCONNECT AND MAKE

SAFE ELECTRICAL UTILITY CONNECTION. LOCK-OUT-TAG-OUT ON

ASSOCIATED CIRCUIT BREAKERS DURING CONSTRUCTION. DEMOLISH

ASSOCIATED JUNCTION BOX. DISCONNECT FUEL OIL PIPING AND CAP

DURING CONSTRUCTION.

DEMOLISH EXISTING FURNACE FLUE VENT INCLUDING DUCTWORK,

SUPPORTS, CONNECTIONS, AND ALL ASSOCIATED ACCESSORIES.

DEMOLISH EXISTING SUPPLY AIR TERMINAL .

DEMOLISH EXISTING CENTRIFUGAL FAN INCLUDING STRUCTURAL

EQUIPMENT PAD, TRANSITION DUCTWORK, AND ASSOCIATED

ACCESSORIES. DISCONNECT AND MAKE SAFE ELECTRICAL UTILITY

CONNECTION AND DISCONNECT SWITCH CONNECTION.

LOCK-OUT-TAG-OUT ON ASSOCIATED CIRCUIT BREAKERS DURING

CONSTRUCTION. REFER TO M-501 FOR PAD DEMOLITION.

EXISTING ELECTRICAL CONDUIT DOWN TO GATE CHAMBER EXISTING TO

REMAIN.

EXISTING CENTRIFUGAL FAN DISCONNECT SWITCH AND EXISTING

JUNCTION BOX TO BE DEMOLISHED. REFER TO SHEET M-101 FOR NEW

WORK.

DEMOLISH EXISTING WARM AIR FURNACE EMERGENCY SHUT-OFF SWITCH

INCLUDING SWITCH BOX AND CONTROL WIRING BACK TO CEILING

MOUNTED CONDUIT BRANCH.

DEMOLISH COMBUSTION AIR INTAKE DUCTWORK UP TO OPERATING ROOM

ACCESS LADDER HATCH AND ALL ASSOCIATED ACCESSORIES AND

SUPPORTS.

A

B

1. UTILITIES SHALL BE DISCONNECTED IN ACCORDANCE WITH ALL

CODES DEFINED IN THESE CONTRACT DOCUMENTS. CONTRACTOR

SHALL VERIFY COMPLIANCE AND COR APPROVAL OF UTILITY

DISCONNECTIONS.

2. SCOPE OF DUCTWORK TO BE DEMOLISHED SHALL INCLUDE

FITTINGS, HANGERS, AND ASSOCIATED ACCESSORIES.

3. EXISTING TO REMAIN DUCTWORK SHALL BE CUT AND CAPPED

DURING CONSTRUCTION TO PREVENT DEBRIS ACCUMULATION.

4. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR

SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS

AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO

DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.

5. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.

6. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED

SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY

REQUIREMENTS.

7. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL

EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"

CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS

RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL

DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.

SHEET GENERAL NOTES

C

D

E

F

G

DEMOLISH EXISTING FAN,

CONCRETE PAD, AND DUCT

CONNECTION UP TO FLEXIBLE

DUCT CONNECTION

INCLUDING THE CONNECTOR.

ELECTRICAL

DISCONNECT

TO BE

DEMOLISHED

EXISTING CENTRIFUGAL FAN

H

James.M.Newman

14"x12" SA

TERMINAL ETR.

600 CFM

16"x8" SA UP ETR

20"x12" SA DOWN ETR

T

CHIMNEY ETR

ELEVATOR

ELECTRICAL PANEL, SUPPLIER

OF FAN AND WARM AIR

FURNACE, 'N2', ETR

GATE OPERATING

EQUIPMENT ETR

ACCESS HATCH

A

S

ACCESS

LADDER

HATCH

EXTERIOR

WALKWAY

MAIN ENTRY

DOOR

WARM AIR FURNACE

WALL SURFACE MOUNTED

EMERGENCY SHUT-OFF

SWITCH ETR

14"x12" SA

TERMINAL

ETR. 600

CFM

16"x8" SA

DOWN ETR

HATCH

CHIMNEY ETR

GENERATOR ASSEMBLY ETR

APPROXIMATE LOCATION

OF OVERHEAD CRANE

ACCESS

LADDER

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SCALE: 3/8" = 1'-0"

OPERATING ROOM DEMOLITION FLOOR PLAN (EL. 790.5)

E1

SCALE: 3/8" = 1'-0"

EQUIPMENT ROOM DEMOLITION FLOOR PLAN (EL. 804.5)

E11

MD102

M E

C H

A N

I C

M

O L

I T

I O

N

F L

O O

R

P

L A

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

A U

G

4'0 2' 8' 4'0 2' 8'

NORTH

SHEET KEYNOTES

DEMOLISH EXISTING WALL MOUNTED THERMOSTAT AND CONTROL WIRING.

IF UNIT CONTAINS MERCURY, CONTRACTOR SHALL CONFORM TO LOCAL

CODES AND REGULATION FOR SAFE DISPOSAL.

A

1. DUCTWORK TO BE DEMOLISHED SHALL INCLUDE FITTINGS,

HANGERS, AND ASSOCIATED ACCESSORIES.

2. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR

SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS

AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO

DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.

3. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.

4. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED

SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY

REQUIREMENTS.

5. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL

EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"

CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS

RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL

DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.

SHEET GENERAL NOTES

James.M.Newman

TERMINAL ETR.

600 CFM

14"x12" SA

TERMINAL ETR.

600 CFM

16"x8" SA

ETR

20"x12" SA

ETR

12"Ø SA

ETR

CHIMNEY ETR

EL. 804.5 EQUIPMENT ROOM

EL. 790.5 OPERATING ROOM

EL. 777.0 HEATER ROOM

LIMIT

DEMOLITION

A

C

20"x12" SA

TBD

T

30"Ø AIR

VENT ETR

B

D

XN

XN

E

EL. 816.0 ROOF LEVEL

A

A

B B

12"Ø SA

ETR

12"x6" SA

TBD

12"x6" SA

TBD

EL. 627.0

EL. 591.5 GATE CHAMBER

30"Ø AIR

VENT ETR

FLOOR

DRAIN ETR

B

B

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SCALE: 3/16" = 1'-0"

TOWER SECTION DEMOLITION PLAN B-B

A5

MD201

M E

C H

A N

I C

W

C

T I O

N

D E

M O

L I T

I O

N

P

L A

N

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

A U

G

8'0 4' 16'

KEY PLAN

NORTH

SHEET KEYNOTES

DEMOLISH WARM AIR FURNACE INCLUDING BLOWER MOTOR AND

ASSOCIATED DUCTWORK AND ACCESSORIES. DISCONNECT AND MAKE

SAFE ELECTRICAL UTILITY CONNECTION. LOCK-OUT-TAG-OUT ON

ASSOCIATED CIRCUIT BREAKERS DURING CONSTRUCTION. DEMOLISH

ASSOCIATED JUNCTION BOX. DISCONNECT FUEL OIL PIPING AFTER

DE-AERATOR AND CAP DURING CONSTRUCTION.

DEMOLISH EXISTING SUPPLY AIR TERMINAL .

DEMOLISH EXISTING CENTRIFUGAL FAN INCLUDING STRUCTURAL

EQUIPMENT PAD, TRANSITION DUCTWORK, AND ASSOCIATED

ACCESSORIES. DISCONNECT AND MAKE SAFE ELECTRICAL UTILITY

CONNECTION AND DEMOLISH DISCONNECT SWITCH. LOCK-OUT-TAG-OUT

ON ASSOCIATED CIRCUIT BREAKERS DURING CONSTRUCTION. DEMOLISH

ASSOCIATED JUNCTION BOX.

DEMOLISH EXISTING WALL MOUNTED WARM AIR FURNACE THERMOSTAT

AND CONTROL WIRING. IF UNIT CONTAINS MERCURY, CONTRACTOR SHALL

CONFORM TO LOCAL CODES AND REGULATION FOR SAFE DISPOSAL.

DEMOLISH COMBUSTION AIR INTAKE DUCTWORK UP TO OPERATING ROOM

ACCESS LADDER HATCH AND ALL ASSOCIATED ACCESSORIES AND

SUPPORTS.

A

B

1. UTILITIES SHALL BE DISCONNECTED IN ACCORDANCE WITH ALL

CODES DEFINED IN THESE CONTRACT DOCUMENTS. CONTRACTOR

SHALL VERIFY COMPLIANCE AND COR APPROVAL OF UTILITY

DISCONNECTIONS.

2. DUCTWORK TO BE DEMOLISHED SHALL INCLUDE FITTINGS,

HANGERS, AND ASSOCIATED ACCESSORIES.

3. EXISTING TO REMAIN DUCTWORK SHALL BE CUT AND CAPPED

DURING CONSTRUCTION TO PREVENT DEBRIS ACCUMULATION.

4. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR

SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS

AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO

DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.

5. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.

6. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED

SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY

REQUIREMENTS.

7. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL

EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"

CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS

RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL

DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.

SHEET GENERAL NOTES

C

D

SCALE: 3/16" = 1'-0"

TOWER SECTION DEMOLITION PLAN A-A

H5

8'0 4' 16'

EXISTING OIL FIRED WARM AIR FURNACE

EXISTING CENTRIFUGAL FAN

E

DEMOLISH EXISTING FAN,

CONCRETE PAD, AND DUCT

CONNECTION UP TO FLEXIBLE

DUCT CONNECTION INCLUDING

THE CONNECTOR.

ELECTRICAL

DISCONNECT

TO BE

DEMOLISHED

FUEL

OIL PIPE

ETR

COMBUSTION

AIR INTAKE

DUCTWORK

TO BE

DEMOLISHED

DE-AERATOR

ETR. CAP

FUEL OIL

PIPING

AFTER

DE-AERATOR.

James.M.Newman

CHIMNEY

20"x12" SA UP

12"Ø SA DOWN

EXISTING

FUEL

PUMP

EXISTING FUEL STORAGE TANKS

12"x6"

SA

30" AIR VENT

DOWN. 30" AIR

VENT UP TO

INTAKE LOUVER

(TYP 3)

EXISTING

1/2" FUEL

OIL PIPE

OVERHEAD

ACCESS HATCH

EXISTING ELECTRICAL POWER PANEL

ELEVATOR

20"x12"

SA

HATCH

S

VD

WARM AIR FURNACE

CONCENTRIC VENT UP

WAF

TF

SA

12"Ø SA UP

12"x12" SA

12"x6" SA

12"x6" SA

12"x6" SA

DOWN TO

SA-1 36"

AFF.

12"x6" SA DOWN

TO SA-1 36" AFF.

T

CTE

TO WAF-1

EXISTING

FLOOR

DRAIN

EXISTING

30"Ø AIR

VENT UP

GATE

CHAMBER

CYLINDER 1

GATE

CHAMBER

CYLINDER 2

GATE

CHAMBER

CYLINDER 3

EXISTING

30"Ø AIR

VENT UP

EXISTING

30"Ø AIR

VENT UP

GATE

CHAMBER

CYLINDER 4

GATE

CHAMBER

CYLINDER 5

GATE

CHAMBER

CYLINDER 6

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SCALE: 3/8" = 1'-0"

HEATER ROOM FLOOR PLAN (EL. 777.0)

E10

M-101

M E

C H

A N

I C

O O

R

P

L A

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

A U

G

SCALE: 3/8" = 1'-0"

GATE CHAMBER FLOOR PLAN (EL. 591.5)

E1

4'0 2' 8'4'0 2' 8'

NORTH

SHEET KEYNOTES

INSTALL NEW WALL MOUNTED WARM AIR FURNACE THERMOSTAT INCLUDING

WATER-TIGHT CONTROL BOX 48" AFF. INSTALL NEW LOW VOLTAGE WIRING TO

EXISTING CONDUIT/WIRING UP TO WAF-1.

INSTALL NEW DIRECT VENT WARM AIR FURNACE, WAF-1, ACCORDING TO

MANUFACTURER'S GUIDELINES INCLUDING BLOWER MOTOR, CONCENTRIC

VENT DUCTWORK, AND ASSOCIATED ACCESSORIES. RECONNECT FUEL OIL

PIPING, DE-AERATOR, AND ELECTRICAL THERMOSTAT CONNECTIONS. INSTALL

NEW JUNCTION BOX AND ASSOCIATED CONTROL WIRING. REROUTE EXISTING

ELECTRICAL WIRING TO REMAIN FROM 20A-1P CIRCUIT BREAKER IN

PANELBOARD 'N2' [CIRCUIT #23] VIA EXISTING EMERGENCY SHUT-OFF SWITCH

ON OPERATING ROOM FLOOR AND NEW FURNACE EMERGENCY SHUT-OFF

SWITCH LOCATION SHOWN TO WAF-1 INTEGRAL JUNCTION BOX. NEW WIRING

SHALL BE 2#12 AWG & 1#12AWG GND IN 3/4" RGS.

INSTALL CONCENTRIC DIRECT VENT WITHIN CHIMNEY UP TO OPERATING

ROOM AND THROUGH SIDEWALL PER MANUFACTURER'S GUIDELINES.

INSTALL NEW CENTRIFUGAL TRANSFER FAN, TF-1, ACCORDING TO

MANUFACTURER'S GUIDELINES INCLUDING VIBRATION ISOLATION

REQUIREMENTS. INSTALL NEW TRANSITION DUCTWORK FROM EXISTING 12"Ø

SA DUCT RISER TO OUTLET OF NEW CENTRIFUGAL FAN. WIRE NEW FAN AND

MOTOR STARTER VIA 3#12 AWG, 1#12 AWG GND IN 3/4" RGS FROM NEW

CENTRIFUGAL FAN DISCONNECT SWITCH.

INSTALL NEW LOW VOLTAGE WIRING TO THERMOSTAT IN GATE CHAMBER.

INSTALL ATTACHED TO EXISTING WIRING/CONDUIT.

12"x6" DOWN TO OED. TERMINATE WITH 1/2" WIREMESH BIRDSCREEN. REFER

TO DETAIL B1 ON M-501 FOR DUCT AND OUTLET ORIENTATION

RECONNECT EXISTING ELECTRICAL WIRING TO REMAIN FROM 15A-3P CIRCUIT

BREAKER IN PANELBOARD 'N2' [CIRCUIT #31, 33, 35] TO NEW 30A CENTRIFUGAL

FAN, F-1, DISCONNECT SWITCH. REFER TO ELECTRICAL PRODUCT

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

INSTALL NEW WALL MOUNTED WARM AIR FURNACE EMERGENCY SHUT OFF

SWITCH 48" AFF INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL

CONDUIT BACK TO WAF-1. RECONNECT TO EXISTING WIRING, WITHIN CEILING

MOUNTED CONDUIT, FROM EXISTING EMERGENCY SHUT OFF SWITCH IN

OPERATOR ROOM.

DUCTWORK SHALL BE CLEANED PER SPECIFICATION REQUIREMENTS

BEFORE NEW CONSTRUCTION WORK.

1. UTILITIES SHALL BE RECONNECTED IN ACCORDANCE WITH ALL

CODES DEFINED IN THESE CONTRACT DOCUMENTS. CONTRACTOR

SHALL VERIFY COMPLIANCE AND COR APPROVAL OF UTILITY

RECONNECTIONS PRIOR TO START UP OF ANY NEW

SYSTEMS/EQUIPMENT.

2. INSTALL NEW DUCTWORK, HANGERS, FITTINGS AND ACCESSORIES

IN ACCORDANCE WITH SPECIFICATIONS AND LOCAL CODES.

3. INSTALL ALL NEW DUCTWORK AND CONDUIT TIGHT TO

STRUCTURE.

4. REFER TO SPECIFICATIONS FOR DUCTWORK CLEANING

GUIDELINES.

5. DUCT ROUTING LOCATIONS AND EQUIPMENT LOCATIONS ARE

ESTIMATED AND SHALL BE FIELD VERIFIED.

6. CONTRACTOR TO REMOVE COVER, CLEAN, AND CLEAR FLOOR

DRAIN IN GATE CHAMBER.

7. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR

SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS

AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO

DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.

8. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.

9. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED

SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY

REQUIREMENTS.

10. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL

EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"

CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS

RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL

DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.

SHEET GENERAL NOTES

AutoCAD SHX Text J

James.M.Newman

EXISTING

TERMINAL.

500 CFM

EXISTING CHIMNEY

16"x8" SA UP

20"x12" SA DOWN

HATCH

T

ELECTRICAL PANEL ETR

GATE OPERATING

EQUIPMENT

ACCESS HATCH

ELEVATOR

S

ACCESS

LADDER

WARM AIR FURNACE WALL

SURFACE MOUNTED EMERGENCY

SHUT-OFF SWITCH

EXISTING

14"x12" SA

TERMINAL.

500 CFM

EXISTING CHIMNEY

16"x8" SA

DOWN

HATCH

GENERATOR ASSEMBLY

APPROXIMATE LOCATION

OF OVERHEAD CRANE

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SCALE: 3/8" = 1'-0"

OPERATING ROOM FLOOR PLAN (EL. 790.5)

E1

SCALE: 3/8" = 1'-0"

EQUIPMENT ROOM FLOOR PLAN (EL. 804.5)

E11

M-102

M E

C H

A N

I C

A L

F L

O O

R

P

L A

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

A U

G

4'0 2' 8' 4'0 2' 8'

NORTH

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

SHEET KEYNOTES

INSTALL NEW WALL SURFACE MOUNTED WARM AIR FURNACE THERMOSTAT

48" AFF INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL, METAL,

SURFACE MOUNTED CONDUIT BACK TO WAF-1.

DUCTWORK AND AIR TERMINALS SHALL BE CLEANED BEFORE NEW

CONSTRUCTION WORK.

INSTALL CONCENTRIC DIRECT VENT THROUGH SIDEWALL PER

MANUFACTURER'S GUIDELINES. VENT SIZING SHALL BE PER

MANUFACTURER'S REQUIREMENTS. PRIOR TO CORING HOLE FOR NEW VENT,

CONTRACTOR SHALL LOCATE EXISTING STEEL REINFORCING BARS TO MAKE

CERTAIN VENT WILL NOT INTERFERE WITH EXISTING STEEL REINFORCEMENT

AS SHOWN ON RECORD DRAWING CON-16-31. CORE FLUE PENETRATION

SIZED TO MANUFACTURER'S INSTALLATION REQUIREMENTS. PROVIDE STEEL

BRACING AND CAST CONCRETE FILL TO MAINTAIN STRUCTURAL INTEGRITY.

INSTALL AIRTIGHT CHIMNEY ACCESS PANEL AS REQUIRE TO ASSIST IN FLUE

INSTALLATION. ENGAGE THE SERVICE OF A PROFESSIONAL ENGINEER

LICENSED IN THE STATE OF CONNECTICUT TO REINFORCE NEW OPENING AS

REQUIRED. SUBMIT DETAILS OF NEW OPENING, AIRTIGHT PANEL, AND

REINFORCING

1. INSTALL ALL NEW CONDUIT TIGHT TO STRUCTURE.

2. REFER TO SPECIFICATIONS FOR DUCTWORK CLEANING

GUIDELINES.

3. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR

SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS

AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO

DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.

4. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.

5. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED

SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY

REQUIREMENTS.

6. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL

EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"

CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS

RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL

DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.

SHEET GENERAL NOTES

WARM AIR FURNACE

CONCENTRIC VENT

DOWN

James.M.Newman

TERMINAL.

600 CFM

14"x12" SA

TERMINAL.

600 CFM

16"x8" SA

20"x12" SA

12"Ø SA

EXISTING

CHIMNEY

EL. 804.5 EQUIPMENT ROOM

EL. 790.5 OPERATING ROOM

EL. 777.0 HEATER ROOM

12"x6"

SA

S

T

VD

EL. 816.0 ROOF LEVEL

WAF

TF

SA

A

A

B B

12"Ø SA

12"x6" SA

12"x6" SA

SA-1

TERMINATE

36" AFF.

SA-1

TERMINATE

36" AFF. 500

CFM

EL. 627.0

EL. 591.5 GATE CHAMBER

30"Ø AIR

VENT

EXISTING

FLOOR

DRAIN

T

SA

SA

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

J

K

L

M

N

P

M-201

M E

C H

A N

I C

W

E R

S E

C T

I O

N

P

L A

N

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

A U

G

8'0 4' 16'

SCALE: 3/16" = 1'-0"

TOWER SECTION PLAN B-B

A5

KEY PLAN

NORTH

SHEET KEYNOTES

INSTALL NEW WARM AIR FURNACE, WAF-1, ACCORDING TO MANUFACTURER'S

GUIDELINES INCLUDING BLOWER MOTOR, CONCENTRIC VENT DUCTWORK,

AND ASSOCIATED ACCESSORIES. INSTALL CONCENTRIC VENT THROUGH

EXISTING CHIMNEY. RECONNECT FUEL OIL PIPING, DE-AERATOR, AND

ELECTRICAL UTILITY CONNECTIONS.

INSTALL NEW CENTRIFUGAL FAN, TF-1, ACCORDING TO MANUFACTURER'S

GUIDELINES INCLUDING VIBRATION ISOLATION REQUIREMENTS, AND

ASSOCIATED ACCESSORIES. RECONNECT ELECTRICAL UTILITY AND EXISTING

FAN DISCONNECT CONNECTIONS. INSTALL NEW TRANSITION DUCTWORK

FROM EXISTING 12"Ø SA DUCT RISER TO OUTLET OF NEW CENTRIFUGAL FAN.

INSTALL NEW WALL MOUNTED WARM AIR FURNACE THERMOSTAT 48" AFF

INCLUDING WATER-TIGHT CONTROL BOX TO PERIMETER WALL. INSTALL NEW

LOW VOLTAGE WIRING TO EXISTING CONDUIT/CABLES UP TO WAF-1. NOTE:

THERMOSTAT SHOWN OF WALL FOR DIAGRAMMATIC PURPOSES ONLY. REFER

TO SHEET M-101 FOR WALL LOCATION.

INSTALL NEW WALL MOUNTED WARM AIR FURNACE EMERGENCY SHUT OFF

SWITCH 48" AFF INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL

CONDUIT BACK TO WAF-1. REFER TO SHEET M-101 FOR WALL LOCATION.

INSTALL NEW WALL MOUNTED WARM AIR FURNACE THERMOSTAT 48" AFF

INCLUDING CONTROL BOX, WIRING, AND ELECTRICAL CONDUIT BACK TO

WAF-1. REFER TO SHEET M-102 FOR WALL LOCATION.

12"x6" OED. TERMINATE WITH 1/2" WIREMESH BIRDSCREEN. REFER TO DETAIL

B1 ON M-501 FOR DUCT AND OUTLET ORIENTATION.

DUCTWORK AND AIR TERMINALS SHALL BE CLEANED BEFORE NEW

CONSTRUCTION WORK.

INSTALL AIRTIGHT CHIMNEY ACCESS PANEL AS REQUIRE TO ASSIST IN FLUE

INSTALLATION. ENGAGE THE SERVICE OF A PROFESSIONAL ENGINEER

LICENSED IN THE STATE OF CONNECTICUT TO REINFORCE NEW OPENING AS

REQUIRED. SUBMIT DETAILS OF NEW OPENING, AIRTIGHT PANEL, AND

REINFORCING.

1. UTILITIES SHALL BE RECONNECTED IN ACCORDANCE WITH

NATIONAL AND LOCAL CODES DEFINED IN THE SCOPE OF WORK.

CONTRACTOR SHALL VERIFY COMPLIANCE OF INSTALLATION

BEFORE SYSTEM FILL AND START UP.

2. NOT ALL COMPONENTS SHOWN FOR CLARITY. CONTRACTOR

SHALL BECOME FAMILIARIZED WITH ACTUAL SITE CONDITIONS

AND SHALL COORDINATE WITH CORPS OF ENGINEERS TO

DETERMINE SAFE AND APPROPRIATE WORK SEQUENCES.

3. INSTALL NEW DUCTWORK, HANGERS, FITTINGS AND ACCESSORIES

IN ACCORDANCE WITH SPECIFICATIONS AND APPLICABLE LOCAL

CODES.

4. REFER TO SPECIFICATIONS FOR DUCTWORK CLEANING

GUIDELINES.

5. CONTRACTOR TO REMOVE COVER, CLEAN, AND CLEAR FLOOR

DRAIN IN GATE CHAMBER.

6. FIELD VERIFY ACTUAL CONDITIONS AND DIMENSIONS.

7. THE TOWER GATE CHAMBER IS A PERMIT REQUIRED CONFINED

SPACE. REFER TO EM-385-1-1 FOR CONFINED SPACE ENTRY

REQUIREMENTS.

8. REFER TO "INFORMATION DRAWINGS" FOR ADDITIONAL

EQUIPMENT INFORMATION. "FOR INFORMATION DRAWINGS"

CONTAIN ORIGINAL DESIGN DOCUMENTS. CONTRACTOR IS

RESPONSIBLE TO FIELD VERIFY ALL INFORMATION TAKE FROM ALL

DOCUMENTATION TO CONFIRM ACCURACY AND RELEVANCE.

SHEET GENERAL NOTES

8'0 4' 16'

SCALE: 3/16" = 1'-0"

TOWER SECTION PLAN A-A

H5

James.M.Newman

1/2" FUEL OIL PIPE CTE

W

L

L=W/4 (4" MIN.)

L

W

45°

MAIN DUCT

45°

RECTANGULAR

BRANCH DUCT

ROUND

FLEXIBLE DUCT

CONNECTION

SUPPLY AIR

DUCTWORK

BLOWER

AND

MOTOR

OIL SHUT OFF

OIL FILTER

CONCENTRIC

DIRECT

VENT KIT

METAL SURFACE

MOUNTED

CONTROL WIRE

CONDUIT.

THERMOSTAT

WITH 1/4"

INSULATING

BASE

ELECTRICAL

JUNCTION BOX

SECURE TO WALL

W/(4) SCREW

ANCHORS.

1" PVC STAND-OFF

FLEXIBLE CONNECTION

TRANSITION (AS REQUIRED)

FAN INLET PROVIDE FLEXIBLE

CONNECTION AND INLET

SCREEN.

WEATHER PROOF MOTOR

HOUSING SHALL HAVE

REMOVABLE PANELS FOR

ACCESS TO MOTOR AND

DRIVE

W = SEE PLANS

FAN SUPPORT PER

MANUFACTURER'S

GUIDELINES. INSTALL WITH

VIBRATION ISOLATION.

FLOOR

WAF-1

TF-1

WAF-1

A

B

SUPPLY AIR

DUCTWORK

SUPPLY AIR

DUCTWORK

A = DISTANCE FROM OED TO

CENTRIFUGAL FAN INTAKE: 6-12"

B = DISTANCE OED TO CENTRIFUGAL

FAN INTAKE: CONSTRUCT AS

NECESSARY TO ALIGN WITH

CENTRIFUGAL FAN INTAKE

CENTER

OED DUCT

TERMINATED W/

WIREMESH

BIRDSCREEN

EXISTING CHIMNEY

SUPPLY AIR

DUCTWORK

FLEXIBLE DUCT

CONNECTION

RAIN CAP

FRONT VIEW

SIDE VIEW

EXTERIOR

WALL

RETURN AIR

VD

OPERATING ROOM

EXTERIOR

WALKWAY

METAL SURFACE

MOUNTED

CONTROL WIRE

CONDUIT.

EMERGENCY SHUT OFF

SWITCH BOX. SECURE TO

WALL W/(4) SCREW

ANCHORS.

1" PVC STAND-OFF

METAL SURFACE MOUNTED

CONTROL WIRE CONDUIT.

THERMOSTAT

WITH 1/4"

INSULATING

BASE

ELECTRICAL JUNCTION

BOX SECURE TO WALL

W/(4) SCREW ANCHORS.

1" PVC STAND-OFF

EMERGENCY FURNACE SHUT OFF SWITCH

WALL MOUNTED THERMOSTAT

WEATHERPROOF WALL MOUNTED

THERMOSTAT

COVER HINGE

WEATHERPROOF COVER

GALVANIZED

ANCHOR SCREW

(TYP)

1-1/4 X 1-1/4 X

3/16 ANGLE

IRON

SUPPORTS.

GALVANIZED,

ADJUSTABLE

VERTICAL DUCT

SUPPORT

BRACKET

VERTICAL

DUCTWORK.

SEE PLANS FOR

DIMENSIONS.

WALL

INSTALL AIRTIGHT CHIMNEY ACCESS

PANEL AS REQUIRE TO ASSIST IN FLUE

INSTALLATION. ENGAGE THE SERVICE OF

A PROFESSIONAL ENGINEER LICENSED IN

THE STATE OF CONNECTICUT TO

REINFORCE NEW OPENING AS

REQUIRED. SUBMIT DETAILS OF NEW

OPENING, AIRTIGHT PANEL, AND

REINFORCING.

EXISTING

ACCESS

PANEL TO BE

USED FOR

INSTALLATION

GALVANIZED

ANCHOR SCREW

(TYP)

1-1/4 X 1-1/4 X

3/16 ANGLE

IRON

SUPPORTS.

GALVANIZED,

ADJUSTABLE

DUCT STRAP

SUPPORT

BRACKET

HORIZONTAL

DUCTWORK.

SEE PLANS FOR

DIMENSIONS.

CONCRETE DECK

EXISTING CONCRETE

FLUSH FLUSH W/

REPAIR MORTAR

ROUGHEN SURFACE

TO ICRI CSP 5

ROUGHEN SURFACE

TO ICRI CSP 5

REMOVE EXISTING

CONCRETE DOWN

TO 2" BELOW TOP OF

EXISTING SLAB.

1" SAW CUT ALL

AROUND

1" (TYP)

CUT EXISTING DOWELS 1"

FROM FACE

EXISTING CONCRETE PAD TO

BE REMOVED

FAN INTAKE

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

M-501

M E

C H

A N

I C

T

A I L

S

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

N

O

S

C A

L E

A U

G

SCALE: NOT TO SCALE

TYPICAL BRANCH CONNECTION DETAIL

L1

SCALE: NOT TO SCALE

CENTRIFUGAL FAN DETAIL

L7

SCALE: NOT TO SCALE

DUCT STRAP HANGER DETAIL

L13

SCALE: NOT TO SCALE

FUEL OIL-FIRED WARM AIR FURNACE, CENTRIFUGAL FAN, AND CONCENTRIC VENT DETAIL

B1

SCALE: NOT TO SCALE

VERITCAL DUCT SUPPORT DETAIL

G13

SCALE: NOT TO SCALE

WALL MOUNTED THERMOSTAT/SWTICH DETAIL

B13

SCALE: NOT TO SCALE

CONCRETE PAD DEMOLITION DETAIL

G1

James.M.Newman

SEQUENCE OF OPERATIONS:

HEATING OPERATION:

1. THE WARM AIR FURNACE SHALL RELY ON A CALL FOR

HEAT FROM EITHER OF THE TWO (2) THERMOSTATS

LOCATED IN THE OPERATING ROOM AND GATE

CHAMBER.

2. THE BURNER AND BLOWER SHALL BE ENGAGED WHEN

EITHER OF THE TWO THERMOSTATS SENSES A

TEMPERATURE BELOW 55°F (ADJ.).

3. THE WARM AIR FURNACE SHALL RUN UNTIL BOTH

THERMOSTATS HAVE REACHED THEIR SETPOINTS AT

WHICH TIME THE BURNER AND BLOWER SHALL

SHUTDOWN AND REMAIN OFF UNTIL A THERMOSTAT

CALLS FOR HEAT.

INLINE FAN SEQUENCE OF OPERATION:

1. THE FAN SHALL OPERATE UNLESS MANUALLY SWITCHED

OFF.

WAF-1

F-1

T

T

EQUIPMENT ROOM

OPERATING ROOM

HEATER ROOM

GATE CHAMBER ROOM

TOWER

HATCH OPENING

HATCH OPENING

HATCH OPENING

HATCH OPENING

RA

RA

RA

RA

500 CFM

500 CFM

500 CFM

500 CFM

500 CFM 500 CFM

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

N

P

M-601

M E

C H

A N

I C

N

T R

A

G R

A

D

S

E Q

U E

N C

E

O

F

O

P E

R A

T I O

N S

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

N

O

S

C A

L E

A U

G

James.M.Newman

US Army Corps of Engineers

U S

A

R M

Y

C

O R

E

N G

I N

E E

R S

N E

W

E

N G

L A

S

T R

I C

T

V

I R

G I N

A

D

C O

N C

O R

D

M

A

D E

S I G

N E

D

B

Y

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

S C

A L E

S

H E

E T

D R

A W

I N

G

C

O D

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

O F

SHEET ID

M A

R K

D E

S C

R I P

T I O

N D

A T

E

G A

T E

H O

U S

E

H

E A

T I N

G

S

Y S

T E

M

R

E P

L A

C E

M E

N T

C O

L E

B R

O O

K

R

I V

K E

C O

L E

B R

O O

K

C

O N

N E

C T

I C

U T

W W

J Q

C O

N C

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

M-602

M E

C H

A N

I C

H

E D

U L

E

M

C

R A

I G

M

C

R A

I G

J

N

E W

M A

N

J

N

E W

M A

N

A N

S I

D

N

O

S

C A

L E

A U

G

UNIT

TAG

DIFFUSER/REGISTER/GRILLE SCHEDULE

MAX PRESSURE

DROP

(IN WC)

.06

CFM

RANGE

SIZE (IN)

NOTES

NOTES:

1. ALUMINUM CONSTRUCTION

2. DUCT MOUNTED

0-500

12X12 SUPPLY

TYPE

OPPOSED BLADE SIDEWALL

.06 0-500

14X24 SUPPLY

OPPOSED BLADE SIDEWALL 1, 2

TYPE

UNIT TAG

MINIMUM

AIRFLOW

NOTES

WARM AIR FURNACE SCHEDULE

NOTES:

1. INSTALL PER MANUFACTURER'S GUIDELINES. PROVIDE WITH DIRECT CONCENTRIC VENT KIT, BLOWER MOTOR, BURNER, SPARE FILTER SET, OIL FILTER, OIL SHUT OFF VALVE, AND REMOTE EMERGENCY SHUT OFF

SWITCH.

2. FURNACE SHALL BE HIGH EFFICIENCY AND NON-CONDENSING.

MINIMUM

INPUT

(MBH)

MINIMUM

OUTPUT

(MBH)

MINIMUM

COMBUSTION

EFFICIENCY

MINIMUM

VENT

CONNECTION

(IN)

ELECTRICAL DATA

(VOLTS/PHASE/HERTZ)

OIL FIRED 2000 CFM245 205 83.7 6 120/1/60 1, 2

UNIT

TAG

CENTRIFUGAL TRANSFER FAN SHEDULE

MINIMUM

AIRFLOW

1000 CFM

STATIC

PRESSURE

DROP (IN

WC)

MINIMUM

MOTOR HP

NOTES

NOTES:

1. INSTALL PER MANUFACTURER'S GUIDELINES. PROVIDE WITH FLOOR MOUNTING FRAME WITH VIBRATION ISOLATION, DISCONNECT SWITCH

CONNECTION, INTAKE SCREEN, AND MOTOR ENCLOSURE. FAN SHALL BE DIRECT DRIVE.

3/4

TYPE

UTILITY SET 1

ELECTRICAL

DATA

(VOLTS/PHASE/HERTZ)

208-230/3/60

TF-1

SA-1

SA-2

WAF-1

MINIMUM

BLOWER

MOTOR

HP

FACTORY EQUIPPED BLOWER POWER REQUIREMENTS

1/3 & 1/2

(AMPS)

12 15 20

3/4 HP BELT DRIVE AND 1

HP DIRECT DRIVE

1 HP BELT

DRIVE

James.M.Newman

Sheets and Views
CON-CL-498_G-001-ANSI 'D'
CON-CL-498_M-001-M-001
CON-CL-498_MD101-MD-101
CON-CL-498_MD102-MD-102
CON-CL-498_MD201-MD201
CON-CL-498_M-101-M-101
CON-CL-498_M-102-M-102
CON-CL-498_M-201-M-201
CON-CL-498_M-501-M-501
CON-CL-498_M-601-M-601
CON-CL-498_M-602-M-602
2022-08-31T10:39:59-0400
JACOBS.LAUREN.ASHLEY.1137790927
2022-08-31T11:00:02-0400
TESSIER.MATTHEW.E.1377053253
I am approving this document
2022-08-31T16:05:51-0400
MARGOLIS.DAVID.I.1228573805

File details come from the government source that posted it. Updated .