DRAFT_SHEET3.pdf

PDF 292 KB Posted

Attached to
DNR Day Use Privy, Kaskaskia
Solicitation number
19-422DNR-LNDMG-B-5146
Issued by
Pope County, Bartelso Village, Illinois

About this file

This document appears to be a technical drawing and specification sheet for the construction of a vault and waste disposal facility for the Indiana Department of Natural Resources (IDNR). The drawings provide detailed plans for the layout, construction, and installation of the facility, including the floor plan, roof framing, elevations, and specifications for various building materials and components such as the masonry walls, concrete slab, waterless toilet, vent piping, and signage. Key requirements include the need for photographic documentation of designated items during installation, proper positioning of the cleanout lid and vent pipe, and specific instructions for the slope and bracing of the vault and vent pipe. The drawings also indicate the use of steel lintels, expansion joints, and other construction details to ensure the structural integrity and functionality of the facility.

The document does not contain any information about pricing, set asides, incumbents, funding sources, or contract terms. It appears to be focused solely on the technical specifications and construction requirements for this particular IDNR project.

View the file

Other files

File Type Posted
Day Use V.T. scope~1.docx DOCX document
DRAFT_SHEET_2OF1.pdf PDF
DRAFT_SHEET2_2.pdf PDF
DRAFT_SHEET4.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

ARCHITECT/ENGINEER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

BY

AutoCAD SHX Text

TRACED BY

AutoCAD SHX Text

PREPARED

AutoCAD SHX Text

BY

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

BY

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

BY

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text R.L.M.

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 3/8" = 1'-0"

AutoCAD SHX Text

PLAN VIEW - VAULT

AutoCAD SHX Text NOTES: 1. DESIGNATED ITEMS REQUIRE A PHOTO DESIGNATED ITEMS REQUIRE A PHOTO AS PROOF ON INSTALLATION. PHOTOS MUST BE SUBMITTED AS PART OF THE APPROPRIATE PAY REQUEST. FAILURE TO SUBMIT THE PHOTO MAY RESULT ON REMOVAL AND RE-INSTALLATION OF THE ITEM.. THIS WILL BE DONE AT THE EXPENSE OF THE CONTRACTOR REGARDLESS OF THE RESULT OF THE INSTALLATION. 2. INSTALL CLEANOUT LID SO THAT THE LID INSTALL CLEANOUT LID SO THAT THE LID HINGE IIS ON THE WALL SIDE OF THE OPENING 3. VENT TO BE LOCATED IN THE FIELD SO THAT IT FACES THE PREVAILING WIND. LOCATION TO BE COORDINATED BY THE IDNR PROJECT MANAGER.

AutoCAD SHX Text B

AutoCAD SHX Text 3/8" = 1'-0"

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text C

AutoCAD SHX Text 3/8" = 1'-0"

AutoCAD SHX Text

ROOF FRAMING PLAN

AutoCAD SHX Text D

AutoCAD SHX Text 3/8" = 1'-0"

AutoCAD SHX Text

FRONT ELEVATION

AutoCAD SHX Text ACCESSIBLE SIGNAGE MOUNTED TO STRETCHER BLOCK. WITH SILICON ADHESIVE. COLOR SHALL OF THE STRETCHER BLOCK SHALL MATCH THE SURROUNDING MASONRY UNITS.

AutoCAD SHX Text

8" MASONRY UNITS W/HORIZONTAL REINFORCING AT ALTERNATING COURSES

AutoCAD SHX Text SELF-ADHERING MEMBRANE 18" WIDE CENTERED ON JOINT OF VAULT. SEE NOTE #1SEE NOTE #1

AutoCAD SHX Text COATED HOLLOW METAL DOOR FRAME WITH FACTORY APPLIED BITUMINOUS COATING ON THE INSIDE AND FILLED WITH GROUT. SEE NOTE #1SEE NOTE #1

AutoCAD SHX Text

12" OF COMPACTED CA-6

AutoCAD SHX Text

SOLATUBE WITH INTEGRAL FLASHING AND CLASSIC VUSION DIFFUSER

AutoCAD SHX Text

PRE-FINISHED METAL DRIP EDGE.

AutoCAD SHX Text

1 X 4 CEDAR TRIM.

AutoCAD SHX Text

RIDGE VENT

AutoCAD SHX Text

8" MASONRY UNITS W/HORIZONTAL REINFORCING AT ALTERNATING COURSES

AutoCAD SHX Text SELF-ADHERING MEMBRANE 18" WIDE CENTERED ON JOINT OF VAULT. SEE NOTE #1SEE NOTE #1

AutoCAD SHX Text

CAR SIDING

AutoCAD SHX Text

COMPACTED CA-6

AutoCAD SHX Text

6" CONCRETE SLAB W/6 X 6 W1.4 X W1.4 WELDED WIRE REINFORCING

AutoCAD SHX Text EXPANSION JOINT WITH #5 SMOOTH COATED DOWEL, 18" LONG CENTERED BETWEEN SLAB AND TOP OF VAULT 24" O.C. SEE NOTE #1

AutoCAD SHX Text

OPENING FOR WATERLESS TOILET, SEE DETAIL A SHEET A-2

AutoCAD SHX Text

TANK #1

AutoCAD SHX Text

TANK #2

AutoCAD SHX Text

CLEANOUT OPENING W/CAST IRON FRAME AND HINGED LID FOR EASY ACCESS. SEE NOTE #2

AutoCAD SHX Text

OPENING FOR VENT PIPE

AutoCAD SHX Text

GRAB BAR

AutoCAD SHX Text

8" MASONRY UNITS W/HORIZONTAL REINFORCING AT ALTERNATING COURSES

AutoCAD SHX Text

WATERLESS TOILET, SEE DETAIL A SHEET A-2

AutoCAD SHX Text

6" CONCRETE SLAB W/6 X 6 W1.4 X W1.4 WELDED WIRE REINFORCING

AutoCAD SHX Text

COAT HANGER MOUNTED 48" ABOVE FINISH FLOORS IN BOTH TOILET ROOMS

AutoCAD SHX Text

6" CONCRETE SIDEWALK W/6 X 6 W1.4 X W1.4 WELDED WIRE REINFORCING

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

2 X 6 FASCIA

AutoCAD SHX Text

2 X 6 TRUSS WITH 2 X 4 BOTTOM CHORD

AutoCAD SHX Text 12" DIAMETER VENT PIPE WITH BOOT FLASHING AT THE ROOF PENETRATION. FABRICATE A CAP AND HARDWARE CLOTH SCREEN FOR VENT PIPE. CAP AND BRACKETS TO BE PAINTED FLAT BLACK.

AutoCAD SHX Text E

AutoCAD SHX Text 3/8" = 1'-0"

AutoCAD SHX Text

SIDE ELEVATION

AutoCAD SHX Text SLOPE THE TANK 1/8" PER FOOT TOWARDS THE DOOR. THIS WILL AID IN THE MAINTENANCE OF THE FACILITY

AutoCAD SHX Text A-2

AutoCAD SHX Text G

AutoCAD SHX Text C

AutoCAD SHX Text A-2

AutoCAD SHX Text B

AutoCAD SHX Text A-2

AutoCAD SHX Text D

AutoCAD SHX Text A-2

AutoCAD SHX Text F

AutoCAD SHX Text A-2

AutoCAD SHX Text F

AutoCAD SHX Text A-2

AutoCAD SHX Text MASONRY VENT ON THE SECOND COURSE, BOTH SIDES. PROVIDE A PRIMED AND PAINTED 38" STEEL LINTEL OVER THE VENT. LINTEL TO LAP ADJACENT BLOCK A MINIMUM OF 3".

AutoCAD SHX Text 12" DIAMETER VENT PIPE WITH BOOT FLASHING AT THE ROOF PENETRATION. FABRICATE A CAP AND HARDWARE CLOTH SCREEN FOR VENT PIPE. CAP AND BRACKETS TO BE PAINTED FLAT BLACK.

AutoCAD SHX Text

RIDGE VENT

AutoCAD SHX Text

10" DIAMETER OPENING FOR SOLATUBE

AutoCAD SHX Text

SLOPE VAULT " PER FOOT TOWARDS DOOR18" PER FOOT TOWARDS DOOR

AutoCAD SHX Text

BRACE VENT PIPE TO ROOF FRAMING. SEE ROOF FRAMING PLAN "C"

AutoCAD SHX Text

TOILET PAPER DISPENSER

AutoCAD SHX Text 2 X 4 BRACING FOR VENT PIPE. FASTEN VENT PIPE TO 2 X 4'S WITH TOTAL OF (4) - STAINLESS STEEL LAG BOLTS - ONE EACH IN ADJOINING FRAMING MEMBER.

AutoCAD SHX Text

STANDING SEAM METAL ROOF

AutoCAD SHX Text

5" COMMERCIAL GRADE GUTTER WITH DOWN SPOUT. COLOR TO MATCH ROOF. FRONT SIDE ONLY

AutoCAD SHX Text FULLY FASTEN PIPE TO CONCRETE VAULT WITH EXTERIOR GRADE CONSTRUCTION ADHESIVE. VENT PIPE SHALL PENETRATE THE OPENING IN THE VAULT BY 8" FROM THE TOP OF VAULT. BRACE PIPE FROM BELOW UNTIL CURED.

AutoCAD SHX Text 4-17-024

AutoCAD SHX Text 11-15-2018

Sheets and Views
100% ARCH SHEET 2004-A-1

File details come from the government source that posted it. Updated .