DRAFT_SHEET3.pdf
PDF 292 KB Posted
- Attached to
- DNR Day Use Privy, Kaskaskia
- Solicitation number
- 19-422DNR-LNDMG-B-5146
- Issued by
- Pope County, Bartelso Village, Illinois
About this file
This document appears to be a technical drawing and specification sheet for the construction of a vault and waste disposal facility for the Indiana Department of Natural Resources (IDNR). The drawings provide detailed plans for the layout, construction, and installation of the facility, including the floor plan, roof framing, elevations, and specifications for various building materials and components such as the masonry walls, concrete slab, waterless toilet, vent piping, and signage. Key requirements include the need for photographic documentation of designated items during installation, proper positioning of the cleanout lid and vent pipe, and specific instructions for the slope and bracing of the vault and vent pipe. The drawings also indicate the use of steel lintels, expansion joints, and other construction details to ensure the structural integrity and functionality of the facility.
The document does not contain any information about pricing, set asides, incumbents, funding sources, or contract terms. It appears to be focused solely on the technical specifications and construction requirements for this particular IDNR project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Day Use V.T. scope~1.docx | DOCX document | |
| DRAFT_SHEET_2OF1.pdf | ||
| DRAFT_SHEET2_2.pdf | ||
| DRAFT_SHEET4.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text
ARCHITECT/ENGINEER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
BY
AutoCAD SHX Text
TRACED BY
AutoCAD SHX Text
PREPARED
AutoCAD SHX Text
BY
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
BY
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
BY
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text R.L.M.
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text 3/8" = 1'-0"
AutoCAD SHX Text
PLAN VIEW - VAULT
AutoCAD SHX Text NOTES: 1. DESIGNATED ITEMS REQUIRE A PHOTO DESIGNATED ITEMS REQUIRE A PHOTO AS PROOF ON INSTALLATION. PHOTOS MUST BE SUBMITTED AS PART OF THE APPROPRIATE PAY REQUEST. FAILURE TO SUBMIT THE PHOTO MAY RESULT ON REMOVAL AND RE-INSTALLATION OF THE ITEM.. THIS WILL BE DONE AT THE EXPENSE OF THE CONTRACTOR REGARDLESS OF THE RESULT OF THE INSTALLATION. 2. INSTALL CLEANOUT LID SO THAT THE LID INSTALL CLEANOUT LID SO THAT THE LID HINGE IIS ON THE WALL SIDE OF THE OPENING 3. VENT TO BE LOCATED IN THE FIELD SO THAT IT FACES THE PREVAILING WIND. LOCATION TO BE COORDINATED BY THE IDNR PROJECT MANAGER.
AutoCAD SHX Text B
AutoCAD SHX Text 3/8" = 1'-0"
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text C
AutoCAD SHX Text 3/8" = 1'-0"
AutoCAD SHX Text
ROOF FRAMING PLAN
AutoCAD SHX Text D
AutoCAD SHX Text 3/8" = 1'-0"
AutoCAD SHX Text
FRONT ELEVATION
AutoCAD SHX Text ACCESSIBLE SIGNAGE MOUNTED TO STRETCHER BLOCK. WITH SILICON ADHESIVE. COLOR SHALL OF THE STRETCHER BLOCK SHALL MATCH THE SURROUNDING MASONRY UNITS.
AutoCAD SHX Text
8" MASONRY UNITS W/HORIZONTAL REINFORCING AT ALTERNATING COURSES
AutoCAD SHX Text SELF-ADHERING MEMBRANE 18" WIDE CENTERED ON JOINT OF VAULT. SEE NOTE #1SEE NOTE #1
AutoCAD SHX Text COATED HOLLOW METAL DOOR FRAME WITH FACTORY APPLIED BITUMINOUS COATING ON THE INSIDE AND FILLED WITH GROUT. SEE NOTE #1SEE NOTE #1
AutoCAD SHX Text
12" OF COMPACTED CA-6
AutoCAD SHX Text
SOLATUBE WITH INTEGRAL FLASHING AND CLASSIC VUSION DIFFUSER
AutoCAD SHX Text
PRE-FINISHED METAL DRIP EDGE.
AutoCAD SHX Text
1 X 4 CEDAR TRIM.
AutoCAD SHX Text
RIDGE VENT
AutoCAD SHX Text
8" MASONRY UNITS W/HORIZONTAL REINFORCING AT ALTERNATING COURSES
AutoCAD SHX Text SELF-ADHERING MEMBRANE 18" WIDE CENTERED ON JOINT OF VAULT. SEE NOTE #1SEE NOTE #1
AutoCAD SHX Text
CAR SIDING
AutoCAD SHX Text
COMPACTED CA-6
AutoCAD SHX Text
6" CONCRETE SLAB W/6 X 6 W1.4 X W1.4 WELDED WIRE REINFORCING
AutoCAD SHX Text EXPANSION JOINT WITH #5 SMOOTH COATED DOWEL, 18" LONG CENTERED BETWEEN SLAB AND TOP OF VAULT 24" O.C. SEE NOTE #1
AutoCAD SHX Text
OPENING FOR WATERLESS TOILET, SEE DETAIL A SHEET A-2
AutoCAD SHX Text
TANK #1
AutoCAD SHX Text
TANK #2
AutoCAD SHX Text
CLEANOUT OPENING W/CAST IRON FRAME AND HINGED LID FOR EASY ACCESS. SEE NOTE #2
AutoCAD SHX Text
OPENING FOR VENT PIPE
AutoCAD SHX Text
GRAB BAR
AutoCAD SHX Text
8" MASONRY UNITS W/HORIZONTAL REINFORCING AT ALTERNATING COURSES
AutoCAD SHX Text
WATERLESS TOILET, SEE DETAIL A SHEET A-2
AutoCAD SHX Text
6" CONCRETE SLAB W/6 X 6 W1.4 X W1.4 WELDED WIRE REINFORCING
AutoCAD SHX Text
COAT HANGER MOUNTED 48" ABOVE FINISH FLOORS IN BOTH TOILET ROOMS
AutoCAD SHX Text
6" CONCRETE SIDEWALK W/6 X 6 W1.4 X W1.4 WELDED WIRE REINFORCING
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
2 X 6 FASCIA
AutoCAD SHX Text
2 X 6 TRUSS WITH 2 X 4 BOTTOM CHORD
AutoCAD SHX Text 12" DIAMETER VENT PIPE WITH BOOT FLASHING AT THE ROOF PENETRATION. FABRICATE A CAP AND HARDWARE CLOTH SCREEN FOR VENT PIPE. CAP AND BRACKETS TO BE PAINTED FLAT BLACK.
AutoCAD SHX Text E
AutoCAD SHX Text 3/8" = 1'-0"
AutoCAD SHX Text
SIDE ELEVATION
AutoCAD SHX Text SLOPE THE TANK 1/8" PER FOOT TOWARDS THE DOOR. THIS WILL AID IN THE MAINTENANCE OF THE FACILITY
AutoCAD SHX Text A-2
AutoCAD SHX Text G
AutoCAD SHX Text C
AutoCAD SHX Text A-2
AutoCAD SHX Text B
AutoCAD SHX Text A-2
AutoCAD SHX Text D
AutoCAD SHX Text A-2
AutoCAD SHX Text F
AutoCAD SHX Text A-2
AutoCAD SHX Text F
AutoCAD SHX Text A-2
AutoCAD SHX Text MASONRY VENT ON THE SECOND COURSE, BOTH SIDES. PROVIDE A PRIMED AND PAINTED 38" STEEL LINTEL OVER THE VENT. LINTEL TO LAP ADJACENT BLOCK A MINIMUM OF 3".
AutoCAD SHX Text 12" DIAMETER VENT PIPE WITH BOOT FLASHING AT THE ROOF PENETRATION. FABRICATE A CAP AND HARDWARE CLOTH SCREEN FOR VENT PIPE. CAP AND BRACKETS TO BE PAINTED FLAT BLACK.
AutoCAD SHX Text
RIDGE VENT
AutoCAD SHX Text
10" DIAMETER OPENING FOR SOLATUBE
AutoCAD SHX Text
SLOPE VAULT " PER FOOT TOWARDS DOOR18" PER FOOT TOWARDS DOOR
AutoCAD SHX Text
BRACE VENT PIPE TO ROOF FRAMING. SEE ROOF FRAMING PLAN "C"
AutoCAD SHX Text
TOILET PAPER DISPENSER
AutoCAD SHX Text 2 X 4 BRACING FOR VENT PIPE. FASTEN VENT PIPE TO 2 X 4'S WITH TOTAL OF (4) - STAINLESS STEEL LAG BOLTS - ONE EACH IN ADJOINING FRAMING MEMBER.
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
5" COMMERCIAL GRADE GUTTER WITH DOWN SPOUT. COLOR TO MATCH ROOF. FRONT SIDE ONLY
AutoCAD SHX Text FULLY FASTEN PIPE TO CONCRETE VAULT WITH EXTERIOR GRADE CONSTRUCTION ADHESIVE. VENT PIPE SHALL PENETRATE THE OPENING IN THE VAULT BY 8" FROM THE TOP OF VAULT. BRACE PIPE FROM BELOW UNTIL CURED.
AutoCAD SHX Text 4-17-024
AutoCAD SHX Text 11-15-2018
| Sheets and Views |
| 100% ARCH SHEET 2004-A-1 |
File details come from the government source that posted it. Updated .