DR_0740E0000_59678_A_001_001.PDF

PDF 405 KB Posted

Attached to
SOLICITATION - W912CH-25-R-0205 - LIFT, TRANSMISSION A; NSN: 4910-00-585-3622
Solicitation number
W912CH-25-R-0205
Issued by

About this file

This is a Vendor Item Control Drawing for a 2,000 lb Transmission Lift, issued by the US Army Combat Capabilities Development Command Armaments Center at Rock Island, Illinois. The document details technical specifications for a manually operated hydraulic transmission jack designed to remove and replace transmissions, transfer cases, and differentials from military and commercial wheeled vehicles. Key requirements include a rated load capacity of 2,000 pounds, a platform height adjustable from 10 to 33 inches, a hydraulic lift mechanism operable with no more than 70 pounds of force, and specific control features allowing operators to raise, lower, and tilt the support plate with single-motion controls. The drawing lists three potential vendors: Gray Manufacturing Company, U.S. Jack, and Hein-Werner Corp, each offering a 1-ton transmission jack meeting the specified requirements. The document includes detailed technical specifications for hydraulic fluid, reservoir capacity, wheel design, and overall lift functionality, with a distribution statement approving public release.

View the file

Other files

File Type Posted
DR_0676A0003_59678_A_001_001.PDF PDF
DR_0676A0004_59678_-_001_001.PDF PDF
DR_0676A0001_59678_-_001_001.PDF PDF
DR_0676A0000_59678_-_001_001.PDF PDF
DR_0676A0002_59678_-_001_001.PDF PDF
W912CH25R0205.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C

A

D

D

C

B

A

CONTRACT NUMBER

DAISIZE

SCALE UNIT WT.

DESIGN ACTIVITY

CONTRACTOR

DRAWN BY DATE(YEAR-MO-DA)

CHECKER ENGINEER

ENGINEER QUALITY ENGINEER

DRAWING APPROVAL

DESIGN APPROVAL

B

MODELED BYMATL ENGR

SHEET

TOLERANCE ON ANGLES �#� �$�

2 PLACE DECIMALS �#�

3 PLACE DECIMALS �#�

FORMAT: C_TACOM_ENG_1_0

DRAWING SIZE C

DWG NO.DISTRIBUTION STATEMENT A. APPROVED

FOR PUBLIC RELEASE; DISTRIBUTION IS

UNLIMITED.

NOTES

1. APPLICABLE STANDARDS/SPECIFICATIONS:

A. ASME Y14.100-2017

B. ASME Y14.5-2018

2. IDENTIFICATION OF THE SUGGESTED SOURCE(S)

OF SUPPLY HEREON IS NOT TO BE CONSTRUED AS

A GUARANTEE OF PRESENT OR CONTINUED AVAILABILITY

AS A SOURCE OF SUPPLY FOR THE ITEM(S).

VENDOR ITEM CONTROL DRAWING

1 OF 21/1

0740E000059678C

LIFT, TRANSMISSION,

2000 LB

2016-06-15V. VONDERA

2016-06-15B. VERMULM

J. LANGELJ. MILLER

2015-09-10J. LANGEL

J. LANGEL

THIRD ANGLE PROJECTION

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

APPLICATION

USED ONNEXT ASSY

TRANS LIFT0676A0000

PMIC

MECHANICAL

PROPERTIES

YP

TS

EL2

RA

BH

RH

REVISIONS

APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONREVISION

PRODUCT BASELINE - ERR K16O3016

JMM2025-07-25K25O3003A

SUGGESTED SOURCE(S) OF SUPPLY

PART NO.

VENDOR DATA

NAME & ADDRESS

CAGE

CODE

VENDOR

PART NO.

VENDOR DESCRIPTION

0740E0000-1

GRAY MANUFACTURING COMPANY, INC.

1316 FREDERIC AVE.

P.O. BOX 728

ST. JOSEPH, MO 64502

51849 MM-2000

1 TON MANUAL/HYDRAULIC

TRANSMISSION JACK

0740E0000-2

U.S. JACK

1120 SOUTH CRYSTAL AVENUE

BENTON HARBOR, MI 49022

0E3L5 D-51404

TRANSMISSION JACK, 1 TON

CAPACITY

0740E0000-3

HEIN-WERNER CORP

2120 N PEWAUKEE RD

WAUKESHA, WI 53186

28047 HW93718

1 TON FLOOR STYLE

TRANSMISSION JACK

0740E0000-4 -REMOVED

PART NO. SEE TABLE

THIS DRAWING WAS GENERATED FROM A SOLID MODEL

AND IS CAD MAINTAINED. CHANGES SHALL BE

INCORPORATED BY THE DESIGN ACTIVITY.

1 OF 21/1

0740E000059678C

LIFT, TRANSMISSION,

2000 LB

US ARMY

COMBAT CAPABILITIES DEVELOPMENT COMMAND ARMAMENTS CENTER

ROCK ISLAND, ILLINOIS 61299-5000

2016-06-15V. VONDERA

2016-06-15B. VERMULM

J. LANGELJ. MILLER

2015-09-10J. LANGEL

J. LANGEL

THIRD ANGLE PROJECTION

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

APPLICATION

USED ONNEXT ASSY

TRANS LIFT0676A0000

PMIC

MECHANICAL

PROPERTIES

YP

TS

EL2

RA

BH

RH

REVISIONS

APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONREVISION

VEV2016-06-15 -

PART NO. SEE TABLE

THIS DRAWING WAS GENERATED FROM A SOLID MODEL

AND IS CAD MAINTAINED. CHANGES SHALL BE

INCORPORATED BY THE DESIGN ACTIVITY.

3. TRANSMISSION LIFT REQUIREMENTS

3.1. DESCRIPTION: THE TRANSMISSION LIFT SHALL BE A MANUALLY OPERATED

HYDRAULIC LIFT WITH A MINIMUM CAPACITY OF 2000 POUNDS. THE LIFT SHALL

BE DESIGNED TO REMOVE AND REPLACE TRANSMISSIONS, TRANSFER CASES

AND DIFFERENTIALS OF MILITARY AND COMMERCIAL WHEELED VEHICLES. THE

LIFT OFFERED TO THE GOVERNMENT, WITH ALL OF ITS ASSOCIATED

COMPONENTS AND ACCESSORIES, SHALL MEET ALL OF THE REQUIREMENTS

OF ASME PASE 2014 PART 5, ENTITLED 'TRANSMISSION JACKS' AND ALL FURTHER

REQUIREMENTS DESCRIBED BELOW.

3.2. FUNCTIONAL REQUIREMENTS: THE LIFT SHALL SAFELY LOWER, CONVEY, LIFT

POSITION FOR INSTALLATION AND SUSTAIN VEHICLE TRANSMISSIONS, TRANSFER

CASES AND DIFFERENTIALS WEIGHING UP TO 2000 POUNDS.

3.3. RATED LOAD CAPACITY: THE LIFT SHALL HAVE A RATED LOAD OF NO LESS

THAN 2000 POUNDS. THE LIFT AND ITS HYDRAULIC SYSTEM SHALL RETAIN

THE FULL RATED LOAD CAPACITY IN ALL POSITIONS BETWEEN THE UPPER AND

LOWER LIMITS OF THE LIFTING RANGE.

3.4. PLATFORM POSITIONING: THE HEIGHT POSITION OF THE PLATFORM SHALL

BE ADJUSTABLE WITHIN A LIFTING RANGE BETWEEN A NOMINAL 10 INCHES

FROM THE FLOOR TO NO LESS THAN 33 INCHES FROM THE FLOOR WHEN

MEASURED AT THE CENTER OF THE PLATFORM'S UPPER SURFACE.

3.5. HYDRAULIC LIFT MECHANISM: THE LIFT SHALL INCORPORATE A MANUALLY

OPERATED HYDRAULICALLY POWERED LIFTING MECHANISM FOR RAISING AND

LOWERING THE LOAD. THE LIFTING MECHANISM SHALL RAISE THE RATED LOAD

TO ANY POINT THROUGHOUT THE SPECIFIED LIFTING RANGE WITH NO MORE

THAN 70 POUNDS OF FORCE APPLIED TO THE PUMP LEVER IN THE DIRECTION OF

GRAVITY WITH THE LEVER AT 30° FROM THE HORIZONTAL. THE LIFT MECHANISM

SHALL ROTATE ITS PUMPING POSITION NO LESS THAN 200°. THE LIFT

MECHANISM SHALL PROVIDE THE CAPABILITY FOR THE OPERATOR TO STOP THE

FULLY LOADED LIFT ARM AT ANY POSITION IN ITS DESCENT.

ALL SHEETS ARE MAINTAINED AT

THE SAME REVISION LEVEL

C

A

D

D

C

B

A

DAISIZE

SCALE UNIT WT.

DESIGN ACTIVITY

B

SHEET

FORMAT: C_TACOM_ENG_1_0

DRAWING SIZE C

DWG NO.

REVISIONS

APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONREVISION

VEV2016-06-15PRODUCT BASELINE - ERR K16O3016-

JMM2025-07-25K25O3003A

2 OF 21/1

0740E000059678C

LIFT, TRANSMISSION,

2000 LB

US ARMY

COMBAT CAPABILITIES DEVELOPMENT COMMAND ARMAMENTS CENTER

ROCK ISLAND, ILLINOIS 61299-5000

NOTES CONTINUED

3.6. CONTROLS: RAISING, LOWERING AND TILT CONTROLS SHALL BE ACCESSIBLE

TO PERMIT THE OPERATOR TO OPERATE THE LIFT AND TILT CONTROLS AND

GUIDE THE VEHICLE COMPONENT TO THE MATING SURFACE OF THE VEHICLE

DURING REMOVAL OR REPLACEMENT OF THE VEHICLE COMPONENT WHILE

LYING ON THE FLOOR BESIDE THE LIFT UNDER THE VEHICLE. THERE SHALL

BE ONLY ONE CONTROL KNOB FOR EACH DIRECTION OF MOVEMENT FOR THE

SUPPORT PLATE; THE PUMP HANDLE SHALL RAISE THE SUPPORT PLATE, THE

RELEASE LEVER SHALL LOWER THE SUPPORT PLATE, ONE CONTROL SHALL

TILT THE SUPPORT PLATE SIDE TO SIDE AND ONE CONTROL SHALL TILT THE

SUPPORT PLATE FORWARD AND BACKWARD. IT SHALL NOT BE PERMISSIBLE

TO USE PAIRS OF ADJUSTING CONTROLS THAT REQUIRE TWO SEPARATE

OPERATIONS TO GAIN THE CONTROLLED MOTION IN ONE DIRECTION OF TILT.

THE TILT CONTROLS SHALL INCLUDE A HEXAGONAL PROTRUSION OR FEMALE

SOCKET DRIVE IMPRESSION THAT WILL ALLOW THE APPLICATION OF A WRENCH

TO AID IN POSITION ADJUSTMENT. A HAND HOLD SHALL BE LOCATED AT NO LESS

THAN TWO OF THE FOUR LOWER CORNERS OF THE LIFT, NEAR THE WHEELS,

THAT SHALL AID IN POSITIONING THE FULLY LOADED LIFT.

3.7. HYDRAULIC FLUID: ONLY HYDRAULIC FLUIDS THAT PRODUCE NO ADVERSE

EFFECTS ON HEALTH AND FOR WHICH NO SPECIAL PRECAUTIONS ARE REQUIRED

BEYOND ATTENTION TO GOOD PERSONAL HYGIENE SUCH AS WASHING WITH

SOAP AND WATER SHALL BE USED. A SAFETY DATA SHEET FOR

THE HYDRAULIC FLUID SHALL BE PROVIDED WITH EACH LIFT. THE FLUID USED

IN THE LIFT SHALL BE A GENERAL PURPOSE HYDRAULIC FLUID OF ISO

VISCOSITY GRADE 32 WITH ANTI-WEAR, OXIDATION RESISTANCE, A POUR POINT

AT OR BELOW -40°F AND RUST AND CORROSION PROTECTION. THE HYDRAULIC

FLUIDS AND SEALS SHALL BE COMPATIBLE WITH EACH OTHER. FLUIDS

CONFORMING TO MIL-DTL-17111 WILL BE ACCEPTABLE AS WELL. AIRCRAFT

GRADE FLUIDS AND FIRE RETARDANT FLUIDS ARE NOT REQUIRED.

3.8. RESERVOIR: THE RESERVOIR SHALL HAVE NO LESS THAN 10% SURPLUS

CAPACITY IN EXCESS OF THE QUANTITY OF HYDRAULIC FLUID REQUIRED FOR

THE PISTON TO REACH ITS GREATEST EXTENSION. THE RESERVOIR SHALL

HAVE A FILLER PLUG(S) AND SHALL BE FILLED WITH HYDRAULIC FLUID AT

THE TIME OF DELIVERY.

3.9. WHEELS: THE LIFT SHALL BE EQUIPPED WITH FOUR STEEL CASTER WHEELS

THAT HAVE BALL OR ROLLER BEARINGS. WHEN LOADED TO THE PROOFLOAD

CAPACITY, ALL CASTERS SHALL ROTATE AND SWIVEL FREELY AND THE AXLES

AND CASTERS SHALL NOT DEFORM. CASTERS SHALL BE REPLACEABLE AND

SHALL NOT LOOSEN OR TIGHTEN UNDER SERVICE CONDITIONS.

ALL SHEETS ARE MAINTAINED AT

THE SAME REVISION LEVEL

PART NO. SEE TABLE

DISTRIBUTION STATEMENT A. APPROVED

FOR PUBLIC RELEASE; DISTRIBUTION IS

UNLIMITED.

Sheet 1
Sheet 2