DOTD Equipment Specification 275-000E, Rev. 8-11-26.pdf

PDF 182 KB Posted

Attached to
DOTD Diesel Engine Arc Welder(S42)
Solicitation number
3000026626
Issued by
East Baton Rouge Parish, Baton Rouge City, Louisiana

About this file

This is a technical equipment specification document from the Louisiana Department of Transportation and Development (DOTD) for the procurement of a diesel engine-driven arc welder, 400 amp series. The specification establishes minimum requirements for a new, self-contained, and fully enclosed welding machine that meets all state and federal safety and emission standards. The specification uses the Miller Big Blue 400 Pro as the representative model to establish equivalency evaluation criteria, and equipment of similar style, type, character, quality, features, and purpose will be considered for award. Bidders proposing exceptions or equivalent options must provide manufacturer and product information for evaluation against the minimum requirements, with proposed submittals determined not to be equivalent rejected outright. The number of delivery days after receipt of order may be used as a factor in the award decision.

The specification requires that the proposed equipment be supplied by a manufacturer with at least one authorized dealer within Louisiana capable of providing parts, service, and warranty repairs with properly trained technicians. Each unit must be delivered completely assembled and ready for operation, including a Louisiana safety inspection sticker, and accompanied by comprehensive documentation including dealer service policy, owner's and service manuals in both hardcopy and digital formats, and build sheets detailing all standard and optional features. Bidders must complete and return the specification document with their bid submittal, noting any exceptions or deviations on the designated "Bidder's Exceptions" page; failure to note specification exceptions prior to award may result in rejection of equipment at delivery. Invoices will not be processed for payment until the Equipment Engineer inspects and deems the unit(s) in compliance with specifications.

View the file

Other files

File Type Posted
3000026626.pdf PDF
Louisiana Preference(2019).pdf PDF
U.S. Preference(2019).pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATE OF LOUISIANA

DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT

TECHNICAL SPECIFICATIONS FOR

DIESEL ENGINE DRIVEN ARC WELDER, 400 AMP

SERIES NO. 275-000

EQUIPMENT SPECIFICATION 275-000E

REV. 8/11/2026

GENERAL

This specification sets forth the minimum requirements for a diesel engine driven welding machine that is self-contained and fully enclosed.

Equipment shall be new, a production model of current manufacture, and must meet all state and Federal safety and emission standards in effect at time of order.

REPRESENTATIVE SPECIFICATIONS

A Miller Big Blue 400 Pro, with appropriate options and standard features, was used to develop these specifications and establish equivalency evaluation criteria.

Equipment of similar style, type, character, quality, features, and purpose conforming to the following detailed requirements/specifications will be considered. For evaluation purposes, bidders proposing an exception/equivalent option/feature to those specified herein, may be required to provide manufacturer/product information (catalogue sheets, detailed specifications, pictures, etc.). This information will be evaluated against the minimum requirements of this specification. Proposed submittals that are determined not to be equivalent to the established criteria will be rejected.

LOUISIANA AUTHORIZED DEALER(S)

Proposed item(s) must be from a manufacturer who has at least one (1) authorized dealer within the State of Louisiana where parts and service can be obtained. Authorized dealer(s) must have properly trained technicians plus all other resources necessary to perform warranty and repair services in complete accordance with the manufacturer’s requirements. A letter certifying the ability to meet this requirement, inclusive of the company name(s) and address(es) of the Louisiana authorized dealer(s), should be supplied with the bid submittal and may be required prior to award.

DELIVERY & ACCEPTANCE

Vendor shall perform a test run of each unit to verify that all features and capabilities are operating properly at time of delivery. Documentation of testing may be required prior to acceptance by the Department.

Unit(s) must be delivered completely assembled (including all components, accessories, etc.) and ready for operation without any additional preparation including, but not limited to, ensuring all fluid levels are at their full mark, fuel tank(s) is full, all necessary lubrication has been performed, etc. A Louisiana safety inspection shall be performed on each vehicle prior to delivery and a Louisiana safety inspection sticker properly affixed.

Any unit delivered under this specification is subject to rejection if there is evidence of poor workmanship, by either the vendor or the original manufacturer. Noted defects and/or nonconformance findings may

EQ. SPEC. 275-000E

REV. 8/11/2026

be corrected by the vendor. Corrections must be completed and approved by the Equipment Engineer or his representative prior to final acceptance.

NOTE: The Department will have space available for equipment to be unloaded.

EACH UNIT MUST BE SUPPLIED WITH THE FOLLOWING DOCUMENTATION AT TIME OF DELIVERY:

1. Dealer's Service Policy

2. Owner's/Operator's Manual(s)

a. One (1) Hardcopy

b. One (1) Digital Copy

i. Acceptable Formats: PDF delivered via USB “Flash Drive”, or E-mail

3. Service Manual(s)

a. One (1) Hardcopy

b. One (1) Digital Copy

i. Acceptable Formats: PDF delivered via USB “Flash Drive”, or E-mail

4. Build Sheet(s) – as applicable

a. One (1) Hardcopy

b. Build sheets should be written in plain language (not company specific codes) and include, at a minimum, all standard & optional features of the delivered unit.

NOTE: Invoices will not be processed for payment until the unit(s) have been inspected by the Equipment Engineer or their representative and deemed in compliance with the specifications.

BID SUBMITTALS

Any additions, deletions, or variations from the specifications should be noted in the "Bidder’s Exceptions" page of this specification. Exceptions that are noted to be less than a minimum requirement will not be accepted.

Any additions, deletions or variations from the manufacturer’s standard published specifications should be noted on the "Bidder’s Exceptions" page of this specification. Unless otherwise noted, any items appearing in the manufacturer’s standard published specifications furnished by the Bidder are assumed to be included in the Bidder’s submittal.

Bidder should note on their submittal any installation(s) to the equipment that will be performed by the vendor instead of the manufacturer.

Failure to note any specification exceptions, manufacturer specification alterations, and/or vendor installations prior to award may result in rejection of the equipment at the time of delivery.

THE NUMBER OF DELIVERY DAYS AFTER RECEIPT OF ORDER (ARO) MAY BE USED AS A FACTOR

IN THE AWARD.

EQUIPMENT SPECIFICATIONS

NOTICE TO BIDDERS

Bidder should review the detailed "Equipment Specification" completely and respond to the compliance question at the end of each section by marking “X”, in the space provided, for "Yes" or "No". Mark "Yes" to indicate that the equipment bid meets the section exactly as specified. Mark "No" if there are exceptions to any part of that section.

Exceptions/deviations to any part of the specification are to be detailed on the "Bidder's Exceptions" page of this specification.

IN ORDER TO BE CONSIDERED FOR AWARD, BIDDER SHOULD RETURN THIS SPECIFICATION, COMPLETED IN FULL, WITH

THEIR BID SUBMITTAL.

Note: All values listed below are minimums unless noted otherwise.

1. Diesel Engine Driven Welding Machine

1.1. Engine

1.1.1. Liquid cooled, diesel, 20 HP (min.)

1.1.2. 1350-1550 RPM low idle; 1750-1900 RPM high idle/weld

1.1.3. Automatic engine shutdown – low oil pressure, high coolant temp, low fuel level

Comply: ____Yes ____No

1.2. Electrical System

1.2.1. Welding output range

1.2.1.1. 30 amps to 400 amps; lower than 30 amps and higher than 400 amps are acceptable

1.2.2. Generator output

1.2.2.1. 10 kW min.

1.2.2.2. 120/240 VAC single phase

1.3. Welding Processes

1.3.1. Stick (SMAW)

1.3.2. MIG (GMAW) & Flux-cored (FCAW)

1.3.3. DC TIG (GTAW)

1.3.4. Air carbon arc/Arc gouging (CAC-A)

1.4. Additional Options & Accessories To Be Included

1.4.1. Suitcase wire feeder, with voltage and amperage control (must be from same manufacturer as welder)

1.4.2. MIG/Flux-cored gun, 15 ft. (min.), 300A (min.)

1.4.3. Wireless remote control allowing full control of the machine from a distance of at least 300 ft.

1.4.3.1. Engine start/stop

1.4.3.2. Voltage and amperage control

EQUIPMENT SPECIFICATIONS

1.4.3.3. Engine/machine status

1.4.3.4. Weld process selection

1.4.4. Protective waterproof cover

1.5. Dimensions

1.5.1. 55”-60” long, 22”-28” wide, 30”-36” high* *not including exhaust

1.5.2. 900 lbs. – 1,100 lbs.

BIDDER’S EXCEPTIONS

Instructions: Bidder should note all exceptions in space provided below. List the detail number from the aforementioned specification in the column to the left and the exception in the column to the right. Responses may be typed or hand-written. Handwritten responses must be legible. If additional space is needed, please print a duplicate copy of this sheet. "Bidder’s Exceptions" page(s) should be returned with the bid submittal.

Examples:

1.6 Engine has 325 horsepower

1.18.3 Batteries have 2000 CCA combined.

2.2.8 Crossmembers are 4” channel on 12” centers.

Spec./Detail Reference Exception

STATE OF LOUISIANA
DIESEL ENGINE DRIVEN ARC WELDER, 400 AMP
General
Representative Specifications
Louisiana Authorized Dealer(s)
Delivery & Acceptance
Bid Submittals
NOTICE TO BIDDERS
1. Diesel Engine Driven Welding Machine
1.1. Engine
1.1.1. Liquid cooled, diesel, 20 HP (min.)
1.1.2. 1350-1550 RPM low idle; 1750-1900 RPM high idle/weld
1.1.3. Automatic engine shutdown – low oil pressure, high coolant temp, low fuel level
Comply: ____Yes ____No
1.2. Electrical System
1.2.1. Welding output range
1.2.1.1. 30 amps to 400 amps; lower than 30 amps and higher than 400 amps are acceptable
1.2.2. Generator output
1.2.2.1. 10 kW min.
1.2.2.2. 120/240 VAC single phase
Comply: ____Yes ____No
1.3. Welding Processes
1.3.1. Stick (SMAW)
1.3.2. MIG (GMAW) & Flux-cored (FCAW)
1.3.3. DC TIG (GTAW)
1.3.4. Air carbon arc/Arc gouging (CAC-A)
Comply: ____Yes ____No
1.4. Additional Options & Accessories To Be Included
1.4.1. Suitcase wire feeder, with voltage and amperage control (must be from same manufacturer as welder)
1.4.2. MIG/Flux-cored gun, 15 ft. (min.), 300A (min.)
1.4.3. Wireless remote control allowing full control of the machine from a distance of at least 300 ft.
1.4.3.1. Engine start/stop
1.4.3.2. Voltage and amperage control
1.4.3.3. Engine/machine status
1.4.3.4. Weld process selection
1.4.4. Protective waterproof cover
Comply: ____Yes ____No
1.5. Dimensions
1.5.1. 55”-60” long, 22”-28” wide, 30”-36” high* *not including exhaust
1.5.2. 900 lbs. – 1,100 lbs.
Comply: ____Yes ____No

File details come from the government source that posted it. Updated .