This is a product specification document for ConTech Lighting's CTL84C Series Gallery LED Cylinder Track Luminaires, prepared for a Virginia state or local government procurement opportunity for use in a Gift Shop facility. The specification details three wattage models (10W, 14W, and 20W) with lumen outputs ranging from 1,186 to 2,293 lumens, available in multiple color temperatures (2700K, 3000K, 3500K, and 4000K) with Color Rendering Index options of 83 typical or 90+ CRI. The fixtures feature selectable beam distributions including 10-degree spot, 28-degree medium, 47-degree flood, and wall wash configurations, with lockable precision aiming capabilities offering 360-degree horizontal and 90-degree vertical rotation. All models are compatible with ConTech Lighting's LT/LT2 track systems and Luxbeam Track Systems, with optional compatibility conversions available for Halo Power-Trac, Lazer Track, and Lightolier Lytespan systems through prefix changes in the part number. The specification explicitly states "NO SUBSTITUTIONS" and requires bidders to bid on the exact product specified to ensure compatibility with existing track infrastructure in the Gift Shop.
The luminaires are constructed of die-cast aluminum with integral dimming capability (120V only) compatible with both incandescent forward-phase and electronic low-voltage reverse-phase dimmers, with dimming performance validated across multiple manufacturer models including Leviton, Lutron, Cooper, and Lightolier units. The fixtures carry a five-year replacement warranty and are rated for 50,000 hours at 70 percent lumen maintenance. All models are cCSAus certified to UL standards, suitable for dry locations, and feature standard configuration weights of 2 pounds per fixture. Accessories are available separately, including replacement optics, tempered glass lenses in multiple patterns and colors, honeycomb louvers, barn doors, snoots, and accessory holders. The specification includes detailed photometric data, beam distance calculations, candela curves, and spectral power distribution charts with ANSI/IES TM-30-18 color rendition reporting.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| GENERAL TERMS AND CONDITIONS.pdf | ||
| SPECIAL TERMS AND CONDITIONS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REV1124
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
CTL84C SERIES | Gallery LED Cylinder Track Luminaires
DATE PROJECT TYPE
CATALOG NO.
P1
1. Lumen values are approximate, see photometric test results
2. Juno is a registered trademark of Juno Lighting
3. Halo is a registered trademark of Cooper Lighting
4. Lightolier is a registered trademark of Philips Lighting
WATTAGE
LUMEN OUTPUT1
LIGHT ENGINE
COLOR TEMPERATURE
CRI
BEAM
DRIVER INPUT VOLTAGE
DIMMIMG TYPE
COMPATIBILITY
LISTINGS
WARRANTY
SYSTEM RATING
CTL84C1 CTL84C2 CTL84C3
10W 14W 20W
1186Lm 1649Lm 2293Lm
Single, high lumen output CREE multi-chip LED array
2700K, 3000K, 3500K, 4000K, 3000K Crisp White
83 (80min) / 90+
10° Spot, 28° Medium, 47° Flood, Wall Wash
120V VAC Dimming, 50/60Hz
Incandescent (Forward Phase) and ELV (Reverse Phase)
CTL Units are compatible with ConTech Lighting LT/LT2 Single Circuit/Two Circuit and Luxbeam Track Systems, as well as Juno®2 Lighting Trac-Master™ Systems HTL Units are compatible with Halo3 Power-Trac and Lazer Track Systems LTL Units are compatible with Lightolier4 Lytespan® Systems cCSAus Certified to UL Standards on base models Suitable for Dry Locations
Five (5) year replacement after date of purchase
50,000 Hours @ 70% Lumen Maintenance
5-11/16" Min.
to 9-3/16" Max.
7-3/4"
Ø 3-1/16"
5-11/16" Min.
9" Max.
Ø 3-1/16"
6-3/16"
Accent Model Wall Wash Model
REV0624
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
CTL84C SERIES | Gallery LED Cylinder Track Luminaires
DATE PROJECT TYPE
CATALOG NO.
P2
CTL84C-OPTIC-S - Spot Optic CTL84C-OPTIC-M - Medium Optic CTL84C-OPTIC-F - Flood Optic 5500011 - 2- In. Di�usion Disc
Replacement Optics
Optics can be easily changed in the field for optimal flexibility
Tempered Glass Lenses 2-3/8" Dia.
Requires FA-84 Accessory Holder, FA-85 Snoot or BD84 Barn Doors. See legend for available colors and patterns.
LF16-** 60MM - Tempered Glass Lenses
**Available Color/Patterns -73 (Spread Lens), -LS (Linear Spread Lens), -SL (Soft Light), -SOL (Solite), -UV (Optivex UV Filter), -A (Amber), -B (Blue), -CL (Clear), -DPE (Dichroic Peach), -G (Green), -LB (Light Blue), -R (Red), -RO (Rose), -Y (Yellow)
Honeycomb Louver 2-3/8" Dia.
Requires FA-84 Accessory Holder, FA-85 Snoot or BD84 Barn Doors. Black finish.
FA-16 60MM - Black Honeycomb Louver
BD84 - Black Barn Doors
Barn Doors
Barn doors extend 2-3/4" max.
from face of fixture. Will accept up to two (2) LF16 0MM Lenses or FA-16 60MM Louvers. Black finish.
Width: 3-1/2" to 7-3/4"
FA-85 - Snoot Finish B - Black P - White S - Silver
Snoot 2-3/4" Dia., 1-3/8" D Snoot extends 1" from face of fixture. Will accept up to two
(2) LF16_60MM lenses or FA-16 60MM louvers. For White (−P) and Silver (−S) finishes, the inside surface is black.
Accessory Holder 2-3/4" Dia., 3/8" D Accepts up to two (2) LF16 60MM Lenses or FA-16 60MM Louvers. Black finish.
FA-84 - Black Acessory Holder
ACCESSORY & REPLACEMENT OPTIC ORDERING INFORMATION
Luminaire 84C1 - 10W/1186Lm 84C2 - 14W/1649Lm 84C3 - 20W/2293Lm
Driver Option D - Dimming
Track System
CTL - ConTech HTL - Halo LTL - Lightolier
Finish B - Black P - White S - Silver
Color Temp/CRI 83 (80min) CRI 27 - 2700K 3 - 3000K 35 - 3500K 4 - 4000K
90+ CRI
27C - 2700K 3C - 3000K 35C - 3500K 4C - 4000K 3W - 3000K, Crisp White
Beam S - 10° Spot M - 28° Medium F - 47° Flood WW - Wall Wash Includes Angled Housing and Wall Wash Kicker Accessory
Example Order: CTL84C2M27D P
ORDERING INFORMATION
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
CTL84C SERIES | Gallery LED Cylinder Track Luminaires
DATE PROJECT TYPE
CATALOG NO.
P3
Construction
• Luminaire designed for gallery, museum or retail applications
• Constructed of die-cast aluminum, the cylindrical body provides thermal management
• Lockable, precision aiming adjustment: 360˚+ aiming horizontal rotation, 90˚ vertical rotation
• Integral ON/OFF switch and track polarity indicator are standard
• Fixture weight: 2LBS
• Can accept up to (2) LF16 60MM Lenses or FA-16 60MM Black
Honeycomb Louvers ith the FA-84 Accessory Holder, FA-85 Snoot, or BD84 Black Barn Doors, ordered separately
Performance Summary
• Light engine consists of a single, high lumen output, multi-chip LED array in 2700K, 3000K, 3500K and 4000K color temperatures;
CRI 80 min., 83 typical; high CRI of 90+ available
• The 3000K Crisp White LED delivers 90+ color rendering with additional violet wavelengths that enhance white visibility
• Excellent fixture-to-fixture color consistency within a 2-step MacAdam Ellipse tolerance
• Select from 10° Spot, 28° Medium and 47° Flood beam distribu-tions; optics have been optically engineered to provide a smooth uniform beam, maximizing output and minimizing glare
• Optics can be easily changed in the field for optimal flexibility
• Also available in a wall wash configuration; providing smooth even illumination on vertical surfaces
• Dimming is standard for all wattage options (120V only), allowing smooth illumination down to 10%. Compatible with most Incandes-cent (Forward Phase) and ELV (Reverse Phase) dimmers. For dimmer compatibility, refer to Dimming Specifications sheet.
Fixture Compatibility
• Standard ConTech track luminaires (CTL Units) are cCSAus certified as-is for use with ConTech Lighting LT/LT2 Single Circuit/Two Circuit Track Systems and Luxbeam Track Systems, as well as Juno®1 Lighting Trac-Master™ Systems.
• By changing the prefix in the part number, ConTech can install inserts which make our fixtures compatible with other manufactur-ers. Replace “CTL” with “HTL” for Halo®² Power-Trac and Lazer-Track systems, and “LTL” for Lightolier³ Lytespan™ systems.
For more information, please consult factory.
PRODUCT DETAILS
1. Juno is a registered trademark of Juno Lighting
2. Halo is a registered trademark of Cooper Lighting 3.. Lightolier is a registered trademark of Philips Lighting
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
CTL84C SERIES | Gallery LED Cylinder Track Luminaires
DATE PROJECT TYPE
CATALOG NO.
P4
CCT MULTIPLIERS OUTPUT MULTIPLIERS
CCT STD CRI HIGH CRI CRISP WHITE 10W/SERIES 1 20W/SERIES 3
2700K .949 .842 N/A
3000K N/A .872 .568
3500K 1.02 .895 N/A
4000K 1.04 .916 N/A
.517 .719
Lumen output values fluctuate based on Color Temperature and Luminaire Wattage/Output. To estimate lumen output of these various options, multiply 3000K results by the following:
PHOTOMETRIC MULTIPLICATION FACTORS
1. Accuracy of Rendering Colors 2. Color Appearance of Light Source 3. Dependent on Surrounding Temperatures 4. Colors Present within the Light Source
Wavelength (nm)
350 390 430 470 510 550 590 630 670 710 750
Spectral Power Distribution Chart4
0 90°
15°0° 30°
45°
75°
60°
Candela Curve
BEAM
DISTANCE FOOTCANDLES DIAMETER
(FT.) (FC) (FT.)
4 FT 540.2 2.02
6 FT 240.1 3.03
8 FT 135.0 4.04
10 FT 86.4 5.06
12 FT 60.0 6.07
14 FT 44.1 7.08
Intensity DistributionFixture Delivered Lumens: 2293.29 Total Watts@120V: 19.684 Lumens Per Watt: 116.411 Center Beam Candle Power: 8643 Beam Distribution: 28.37° Spacing Criterion: 0.4748 Color Rendering Index (CRI)1: 83 Color Temperature (CCT)2: 3066K
Designed for 50,000 Hour Lamp Life3
LM-63 Test No. G24012402 LM-79 Test No. S24012601
CTL84C3M3D: Medium Optic
Wavelength (nm)
350 390 430 470 510 550 590 630 670 710 750
Spectral Power Distribution Chart4
30°15°0°
45°
60°
75°
90°
16000
18000
12000
Candela Curve
BEAM
DISTANCE FOOTCANDLES DIAMETER
(FT.) (FC) (FT.)
4' 1073.2 0.70
6' 477.0 1.05
8' 268.3 1.41
10' 171.1 1.76
12' 119.2 2.11
14' 87.6 2.46
Intensity DistributionFixture Delivered Lumens: 2201.07 Total Watts@120V: 19.691 Lumens Per Watt: 111.73 Center Beam Candle Power: 17172 Beam Distribution: 10.04° Spacing Criterion: 0.2918 Color Rendering Index (CRI)1: 83 Color Temperature (CCT)2: 3066K
Designed for 50,000 Hour Lamp Life3
LM-63 Test No. G24012401 LM-79 Test No. S24012601
CTL84C3S3D: Spot Optic
PHOTOMETRICS
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
CTL84C SERIES | Gallery LED Cylinder Track Luminaires
DATE PROJECT TYPE
CATALOG NO.
P5
CCT MULTIPLIERS OUTPUT MULTIPLIERS
CCT STD CRI HIGH CRI CRISP WHITE 10W/SERIES 1 20W/SERIES 3
2700K .949 .842 N/A
3000K N/A .872 .568
3500K 1.02 .895 N/A
4000K 1.04 .916 N/A
.517 .719
Lumen output values fluctuate based on Color Temperature and Luminaire Wattage/Output. To estimate lumen output of these various options, multiply 3000K results by the following:
PHOTOMETRIC MULTIPLICATION FACTORS
1. Accuracy of Rendering Colors 2. Color Appearance of Light Source 3. Dependent on Surrounding Temperatures 4. Colors Present within the Light Source
Wavelength (nm)
380 420 460 500 540 580 620 660 700 740 780
Sp ec tr al
F lu x (W
/n m
Spectral Power Distribution Chart4
30°15°0°
45°
60°
75°
90°
0 Deg.
90 Deg.
180 Deg.
Candela Curve
BEAM
DISTANCE FOOTCANDLES DIAMETER
(FT.) (FC) (FT.)
4 FT 81.4 6.13
6 FT 36.2 9.19
8 FT 20.3 12.25
10 FT 13.0 15.32
12 FT 9.0 18.38
14 FT 6.6 21.44
Intensity DistributionFixture Delivered Lumens: 1674.66 Total Watts@120V: 19.635 Lumens Per Watt: 85.442 Center Beam Candle Power: 1302 Beam Distribution: 72.91° Spacing Criterion: 1.005 Color Rendering Index (CRI)1: 83 Color Temperature (CCT)2: 3066K
Designed for 50,000 Hour Lamp Life3
LM-63 Test No. G24012502 LM-79 Test No. S24012601
CTL84C3WW3D: Wall Wash
Candela CurveIntensity Distribution
BEAM
DISTANCE FOOTCANDLES DIAMETER
(FT.) (FC) (FT.)
4 FT 235.0 3.50
6 FT 104.5 5.25
8 FT 58.8 7.00
10 FT 37.6 8.74
12 FT 26.1 10.49
14 FT 19.2 12.24
CTL84C3F3D: Flood Optic
Fixture Delivered Lumens: 2255.56 Total Watts@120V: 19.695 Lumens Per Watt: 114.496 Center Beam Candle Power: 3761 Beam Distribution: 47.23° Spacing Criterion: 0.7073 Color Rendering Index (CRI)1: 83 Color Temperature (CCT)2: 3066K
Designed for 50,000 Hour Lamp Life3
LM-63 Test No. G24012501 LM-79 Test No. S24012601
0 90°
15°0° 30°
45°
75°
60°
Spectral Power Distribution Chart4
380 420 460 500 540 580 620 660 700 740 780
Sp ec tr al
F lu x (W
/n m
Wavelength (nm)
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2024 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
CTL84C SERIES | Gallery LED Cylinder Track Luminaires
DATE PROJECT TYPE
CATALOG NO.
P6
Colors are for visual orientation purposes only
HUE BIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
HUE SHIFT -1% 7% 11% 7% 4% ¯2% ¯7% ¯1% 3% 7% 11% 1% ¯7% ¯15% ¯14% ¯15%
Rf VALUE 80 81 79 89 94 93 87 94 90 85 84 87 88 81 79 79
R f b y
H ue
Hue Bin
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pe rc en ta ge S hi ft b y
H ue
-30%
-20%
-10%
0%
10%
20%
30%
Hue Bin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Reference Illuminance Test Source
380 430 480 530 580 630 680 730 780
Ra di an t P ow er
(E qu al
L um in ou s
FL
ux
Wavelength (nm)
Spectral Power Distribution Comparison
Reference Illuminance Test Source
10 15
12 13
14+20%
-20%
Color Vector Graphic Rf 86
Rg 96
CCT(K) 3066K
Duv 0.0001 uI 0.2483 vI 0.5201
Colors are for visual orientation purposes onlyANSI/IES TM-30-18 Color Rendition Report Test No. S24012601
TM-30 DATA: NCTL84C3F3CD
Light Output
Manufacturer Model 10W 14W 20W Xicato 16W Xicato 23W
Leviton 6161 13% - 100% 10% - 99% 10% - 99% 13% - 99% 12% - 99%
Leviton IPE04 4% - 100% 3% - 100% 5% - 99% 6% - 99% 6% - 99%
Leviton IPI06-1LZ 0% - 100% 0% - 99% 1% - 99% 1% - 99% –
Leviton VPE06 6% - 100% 5% - 100% 8% - 100% 8% - 100% 9% - 95%
Leviton 6633-P 1% - 100% 0% - 100% – 3% - 100% 2% - 99%
Leviton 6683-IW 2% - 100% 2% - 100% 4% - 100% 13% - 100% –
Cooper DAL06P 1% - 100% 0% - 100% 3% - 100% – –
Cooper DLC03P 1% - 100% 0% - 100% 2% - 100% 2% - 100% 2% - 99%
Cooper SLC03P 0% - 100% 0% - 100% 0% - 100% 1% - 100% 1% - 99%
Lightolier ZP260QEW 4% - 100% 3% - 99% 4% - 99% 4% - 98% 5% - 98%
Lutron CT103P 8% - 100% 6% - 99% 6% - 99% 9% - 99% 10% - 99%
Lutron DVCL-153P 0% - 100% 0% - 99% 0% - 99% – –
Lutron DVELV303P 4% - 99% 3% - 97% 5% - 97% 6% - 96% 6% - 94%
Lutron FAELV500 8% - 100% 7% - 99% 9% - 99% 10% - 99% 11% - 99%
Lutron LG600P – 5% - 99% 5% - 99% – 8% - 99%
Lutron MAELV600 8% - 100% 7% - 99% 9% - 99% 10% - 99% 11% - 99%
Lutron S600P 3% - 100% 1% - 99% – – 5% - 99%
Lutron SELV300P 4% - 98% 3% - 97% 5% - 96% 6% - 95% 7% - 100%
Lutron TG-600P 10% - 100% 13% - 99% 12% - 99% 16% - 99% 15% - 99%
Lutron TGCL-153P 2% - 100% 2% - 99% 4% - 99% – –
CTL84 Series: “D” Driver Option
DIMMING SPECIFICATIONS | Gallery Series Track Luminaires:
CTL84C, CTL84X
• Incandescent 120VAC dimmers adjust the light with “forward phase control,” where the dimmer “chops” the forward part of the AC wave to deliver less or more power to the light source. No neutral wire connection required.
• Electronic low voltage 120VAC dimmers adjust the light with “reverse phase control,” where the dimmer “chops” the back part of the AC wave to deliver less or more power to the light source. Neutral wire connection required.
Notes
1. Testing was performed with a single fixture connected to dimmer.
2. Testing has been performed on these dimmers, but this does not imply any warranty of compatibility.
3. Dimming performance can be influenced by different loads, as well as variations in dimmer switches within the same model.
4. Dimmer maximum load rating with LED may differ from published traditional source dimmer ratings. Consult manufacturer for maximum dimmer information.
5. Consult factory for additional dimming information.
REV0121
CONTECH LIGHTING | 725 LANDWEHR ROAD | NORTHBROOK, ILLINOIS 60062 | PHONE 847.559.5500 | www.contechlighting.com ©2021 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
DATE PROJECT TYPE
CATALOG NO.
| Text1: |
| Text2: |
| Text3: |
| Text4: |
| Dropdown4: [ ] |
| Dropdown6: [ ] |
| Dropdown7: [ ] |
| Dropdown8: [ ] |
| Dropdown9: [D] |
| Dropdown10: [ ] |
| Dropdown12: [ ] |
| Dropdown11: [ ] |
| Dropdown13: [ ] |
| Dropdown14: [ ] |
| Dropdown10ZGNB: [ ] |
| CZV: [ ] |
| Dropdown14dsv: [ ] |
File details come from the government source that posted it. Updated .