CNCC Hefley Gymnasium Limited Asbestos Inspection Report (1).pdf

PDF 2 MB Posted

Attached to
Hefley Gym Floor Demo and Abatement
Solicitation number
CNCC 24-09
Issued by
Pueblo County, Colorado

About this file

The document is a Limited Asbestos Inspection Report prepared by Grande River Environmental, LLC for Colorado Northwestern Community College (CNCC) regarding the Hefley Gymnasium located at 500 Kennedy Avenue in Rangely, Colorado. The inspection was conducted on September 17, 2020, in preparation for replacing the gymnasium floor, and focused on identifying and analyzing potential asbestos-containing materials (ACM) beneath the existing floor. The inspection was performed in accordance with EPA, OSHA, and Colorado Department of Public Health and Environment (CDPHE) regulations, with samples collected and analyzed by an independent laboratory using polarized-light microscopy.

The laboratory analysis revealed vermiculite insulation beneath the gymnasium floor containing less than 0.25% asbestos, which means the material is not governed by EPA or CDPHE regulations and can remain in place during demolition. However, the report emphasizes that any materials containing asbestos require compliance with OSHA Asbestos in Construction Standard, including using wet methods during renovation or demolition and implementing proper worker protection protocols. The inspection was limited to accessible spaces, and the report notes that additional materials might exist in inaccessible areas. Grande River Environmental recommends careful handling and disposal of materials to avoid contaminating site soils, with all waste management following CDPHE Solid Waste Regulations.

View the file

Other files

File Type Posted
CNCCFY24-009 Addendum #3.docx DOCX document
Sign in Sheet.pdf PDF
CNCC FY24-009 Addendum #1.docx DOCX document
CNCCFY24-009 Addendum #6.docx DOCX document
Sample Agreement SC5.3 CON 2022.pdf PDF
Response Sheet.docx DOCX document
CNCC FY24-009 Addendum #2.docx DOCX document
Sign in Sheet 2.pdf PDF
CNCCFY24-009 Addendum #5.docx DOCX document
FY24-009 RFQ - Gym Floor Demo and Abatement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIMITED ASBESTOS INSPECTION REPORT

COLORADO NORTHWESTERN COMMUNITY COLLEGE

HEFLEY GYMNASIUM

500 KENNEDY AVENUE

RANGELY, COLORADO

Inspected by Grande River Environmental, LLC

CDPHE CONSULTING FIRM #18631

September 18, 2020

COLORADO NORTHWESTERN COMMUNITY COLLEGE

HEFLEY GYMNASIUM

Prepared for: Lindsey Blake CNCC Director of Facilities 500 Kennedy Drive Rangely, CO 81648

Prepared by: ______________________________________________________

Travis Brophy, APCD # 13477 Certified Asbestos Inspector

Reviewed by:

Faron Compton, APCD #4166 Certified Asbestos Inspector

Submitted by Grande River Environmental, LLC

Clifton, Colorado 81520

(970) 628-1196

TABLE OF CONTENTS

1 INTRODUCTION

2 ASBESTOS INSPECTION

2.1 Asbestos Sampling Strategy

2.2 Asbestos Laboratory Analyses

2.3 Asbestos Chain-of-Custody

3 ASBESTOS INSPECTION RESULTS

4 CONCLUSIONS & RECOMMENDATIONS

5 QUALIFICATIONS AND LIMITATIONS

LIST OF TABLES

TABLE 1 BULK SAMPLING STRATEGY

TABLE 2 ASBESTOS INSPECTION RESULTS

LIST OF APPENDICES

APPENDIX A ASBESTOS SAMPLING FORMS

APPENDIX B ASBESTOS ANALYTICAL DATA, CHAIN-OF-CUSTODY FORM

APPENDIX C INSPECTOR CERTIFICATIONS

September 18, 2020 1

COLORADO NORTHWESTERN COMMUNITY COLLEGE

HEFLEY GYMNASIUM

1 INTRODUCTION

Grande River Environmental, LLC (GRE) was contracted by Colorado Northwestern Community College (CNCC) to conduct a limited asbestos inspection of materials beneath the Hefley Gymnasium floor located on the CNCC campus. The inspection was conducted in accordance with applicable Environmental Protection Agency (EPA), Occupational Safety and Health Administration (OSHA), and Colorado Department of Public Health and Environment (CDPHE) regulations prior to replacing the gymnasium floor. The purpose of this report is to present the findings of the inspection conducted on September 17, 2020

2 ASBESTOS INSPECTION

Asbestos sampling was completed by Jake Harris, a GRE asbestos inspector certified by the CDPHE and the EPA. Copies of the inspector’s certifications are attached to this report. This survey was performed in accordance with CDPHE Regulation No. 8 and AHERA regulations governing asbestos inspections. An asbestos inspection is required prior to conducting demolition or renovation activities.

Bulk samples of various suspect asbestos-containing materials (ACM) were collected and submitted to an independent laboratory for polarized-light microscopic (PLM) analysis.

Sample locations are described on the attached sample data sheets.

Asbestos sampling is conducted by segregating building materials into sampling units called homogeneous areas. A homogeneous area is defined as a material that is uniform in texture and color and appears identical in every other respect.

Once suspect materials are identified, they are classified as friable or non-friable. The EPA distinguishes between friable and non-friable forms of ACMs. Friable materials, when dry, can be crumbled or reduced to powder by hand pressure, whereas non-friable materials cannot.

Friable materials are more likely to release particulate dust into the air, especially during renovation and demolition activities. Therefore, the distinction between friable and non-friable homogeneous material is important.

September 18, 2020 2

Non-friable materials are further divided into two categories as defined by EPA. Category I non-friable materials that are in good condition may remain during building demolition provided these materials are not rendered friable during demolition. Category II non-friable materials must be removed prior to conducting renovation or demolition activities.

2.1 Asbestos Sampling Strategy

The Bulk Sampling Strategy shown in Table 1 was developed based on EPA and CDPHE regulations and was used to determine the minimum number of samples to be collected of each suspect material.

TABLE 1 – BULK SAMPLING STRATEGY

MATERIAL

HOMOGENEOUS

AREA SIZE UNITS

MINIMUM NUMBER

OF SAMPLES

Surfacing Less than 1,000 SF 3

1,000 to 5,000 SF 5

More than 5,000 SF 7 Thermal System Insulation - - - LF / SF / EA 3

Miscellaneous Materials - - - LF / SF / EA 2 Note: SF = Square feet LF = Linear feet EA = Each

GRE collected bulk samples of the homogeneous materials in a random and representative manner, as determined by the inspector. A minimum of one composite core sample that included all layers within the suspect material was obtained from each homogeneous area. Samples from soft friable materials were obtained by removing a small portion using wetting techniques. The sampler washed equipment following collection of each sample in order to minimize the potential for cross-contamination between samples. The sampler assumed that materials in inaccessible locations were similar to those in accessible locations, in order to limit the amount of destruction in the sampling process. All samples were placed in sealed, labeled containers, and the sample descriptions and locations were recorded.

Accessible spaces were inspected for homogeneous areas of building materials that potentially contain asbestos. The nature, extent, and condition of each type of potential ACM were cataloged. Sampling forms for each homogeneous area were prepared describing the type of material, identifying characteristics, and location of the sample. These forms are included in Appendix A of this report.

2.2 Asbestos Laboratory Analyses

Samples were submitted to an independent laboratory for analysis. Collected samples were analyzed by Reservoirs Environmental Services, Inc. (NVLAP Accreditation No. 101896) of Denver, Colorado, using polarized-light microscopy (PLM), a bulk sample analysis method

September 18, 2020 3 established by the National Voluntary Laboratory Accreditation Program (NVLAP). Bulk asbestos samples were analyzed using EPA Method 600/R-93/116. While the EPA does not “certify” laboratories, analytical methods follow EPA’s recommended protocols using a NVLAP accredited laboratory. The laboratory analytical data report is attached.

2.3 Asbestos Chain-of-Custody

A chain-of-custody record was used to track the possession and transfer of each sample from the time of field collection through laboratory analysis. The record contained the following: sample tag number, signature of collector, date of collection, identification of sampled material, requested laboratory analysis, signatures of individuals in custody of the samples, and record of possession. A copy of the chain-of-custody form is attached.

3 ASBESTOS INSPECTION RESULTS

Laboratory results from the asbestos inspection are summarized below. Samples of materials that contain greater than one percent (>1%) asbestos are considered ACM by the EPA and CDPHE. Samples that contain any amount of asbestos greater than none detected (ND) are recognized and covered by the OSHA Asbestos in Construction Standard found at 29 CFR

1926.1101. Homogeneous material descriptions, locations, and quantities as well as analytical results are summarized in Table 2.

TABLE 2 – ASBESTOS INSPECTION RESULTS

HA MATERIAL

DESCRIPTION

ASBESTOS

CONTENT LOCATION QUANTITY

01 Vermiculite <0.25 Beneath Gymnasium Floor 50,00 CF

NOTES: HA – Homogeneous Area SF – Square Feet CF – Cubic Feet Italics – OSHA Regulated Asbestos-Containing Material Listed quantities are approximate.

4 CONCLUSIONS & RECOMMENDATIONS

This report presents the findings of a limited asbestos inspection conducted on September 17, 2020 at the Hefley Gymnasium on the CNCC campus in accordance with EPA and CDPHE regulations. The objective of this inspection was to identify the location and extent of asbestos-containing materials (ACMs) prior to gymnasium floor removal and replacement.

Bulk samples of suspect ACMs were obtained from the structure and submitted to an independent laboratory for polarized-light microscopic (PLM) analysis. Following are the recommendations to handle the materials based on their asbestos content, friability, and category:

September 18, 2020 4

Vermiculite Insulation – The insulation present beneath the gymnasium floor was identified to contain less than 0.25% asbestos; therefore, the materials are not governed by EPA or CDPHE regulations and may remain in the structure during demolition. However, materials that contain any amount of asbestos require compliance with the OSHA Asbestos in Construction Standard found at 29 CFR 1926.1101. Renovation or demolition activities involving materials that contain less than 1% asbestos require the use of wet methods and prompt clean-up and disposal of debris. The regulation prohibits employee rotation as a means of reducing employee exposure. The standard has other requirements for worker protection during asbestos removal.

If the material will remain in the structure during renovation or demolition, disturbance activities should be conducted in a manner to avoid contaminating site soils. Handling, removal, and disposal of soils containing any amount of asbestos may be regulated under the CDPHE Solid Waste Regulations.

5 QUALIFICATIONS AND LIMITATIONS

GRE conducted this investigation in a manner consistent with current professional practices.

This assessment was limited to the sampling locations and analyses described in the report. No other sampling or analyses were conducted during this investigation. Only readily accessible spaces were inspected; therefore, it is possible that ACM or other hazardous building materials may exist in areas that were inaccessible during this non-destructive inspection. Any materials not identified in this report should be assumed asbestos containing until proven otherwise. It is possible that additional reports or investigations could alter the conclusions of this assessment.

Materials and areas that were not accessed, sampled, and/or assessed include:

• Mechanical equipment interiors, including boilers, furnaces, electrical equipment, and ducting

• Interior of enclosed chases and soffits

• Behind walls that are inaccessible

• Above ceilings that are inaccessible

• Buried or subgrade building materials

Any addition to or alteration of the building should be documented and the inspection report should be amended. THIS DOCUMENT IS NOT INTENDED FOR BIDDING PURPOSES This report is intended for use only by the client. Any future use of this report by anyone other than the above-referenced client will require authorization by GRE and possible updating of the report.

APPENDIX A

ASBESTOS SAMPLING FORMS

APPENDIX B

ASBESTOS ANALYTICAL DATA

CHAIN-OF-CUSTODY FORM

Sincerely, Jeanne Spencer President

Subcontractor Number:

Laboratory Report: RES 473664-2

Project #/P.O. #: None Given

Project Description: CNCC - Gym

Jake Harris Grande River Environmental 562 Huntington Point Lane Clifton CO 81520

Dear Jake, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.

Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request.

The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.

RES 473664-2 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed.

This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested.

If you have any questions about this report, please feel free to call 303-964-1986.

by Emily Giddens

Reservoirs Environmental, Inc Effective April 02, 2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

(303) 964-1986

(866) RESI-ENV

www.reilab.com clients.reilab.com

5801 Logan St, Suite 100, Denver, CO 80216

RES Job Number:

Client:

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 473664-2

Grande River Environmental None Given CNCC - Gym September 18, 2020

Rush September 18, 2020

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective April 2, 2018 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client Sample Number

L A Y E R

Mineral

Method: EPA 600/R-93/116 - Point Count, Bulk (400)

Physical Description

Sub Part

Visual Estimate

ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite

Non Asbestos Fibrous

Components

Non- Fibrous

Components

Asbestos Content

100001-1 Tan vermiculiteA 100 TR Trem/Act <0.25 Point Count

100001-2 Tan vermiculiteA 100 TR Trem/Act <0.25 Point Count

Data QAAnalystAnalystAnalystAnalyst

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986 F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

SUBMITTED BY INVOICE TO

Client Sample ID Number

RES Job #: 473664

CONTACT INFORMATION SERIES

ASBESTOS LABORATORY HOURS: Weekdays: 7am - 7pm & Sat. 8am - 5pm REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES

CHEMISTRY LABORATORY HOURS: Weekdays: 8am - 5pm

MICROBIOLOGY LABORATORY HOURS: Weekdays: 8am - 5pm

**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**

Laboratory Analysis InstructionsViables

(Sample ID's must be unique)

Company: Grande River Environmental Company: Grande River Environmental

Address: 562 Huntington Point Lane Address: 562 Huntington Point Lane

Clifton, CO 81520 Clifton, CO 81520

Project Number and/or P.O. #: None Given

Project Description/Location: CNCC - Gym

Contact: Jake Harris -1 PLM Rush *VERBALS* Phone: (970) 201-9731

Fax:

Cell:

Final Data Deliverable Email Address:

jakeh@granderiverenv.com (+ 4 ADDNL. CONTACTS)

PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B

Dust = D Food = F

Paint = P Soil = S

Dust RUSH PRIORITY STANDARD

*PRIOR NOTICE REQUIRED FOR SAME DAY TAT

Surface = SU Swab = SW

Tape = T Wipe = W

Metals RUSH PRIORITY STANDARD Drinking Water = DW

Waste Water = WW

Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**

Viable Analysis** PRIORITY STANDARD

**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH

Medical Device Analysis RUSH STANDARD

Mold Analysis RUSH PRIORITY STANDARD

Special Instructions:

1 01-1 X B 09/17/20

2 01-2 X B 09/17/20 P

L M

S ho rt

R ep or t

, L on g R ep or t, C

A R

B

T E

M

A H

E R

A o r Q ua nt ifi ed

M ic ro va c o r Q ua nt ifi ed

W ip e o r Q ua nt ifi ed

N

IO

S

H

2, Y am at e

Le ve l I I, IS

O

, I

S O

C ha tfi el d, W as te

W at er , D rin ki ng W at er

, B ul k

, C

A R

B M od ifi ed A he ra

P C

M

A , 7

0B

, O S

H A

D U

S T

To ta l, R es pi ra bl e

M E

TA

L

S

A na ly te

(s

Le ad

O nl y (7

2, 0, W as te

W at er , F oo dw ar e)

, M ul ti M et al

(7

3, A

, 2

.8 , W as te

W at er , F oo dw ar e, O S

H A

ID

-1

G p

H (L iq ui d, N on -L iq ui d)

T C

LP

, R

C R

A

S ca n, W el di ng F um e

S ca n, F ul l M et al s S ca n

O R

G A

N

IC

S

M et ha m ph et am in e, T

S S

C am py lo ba ct er , B ac ill us , S al m on el la (C ul tu ra bl e, -2

L is te ria

E

.c ol i O

7:

H

7, E

.c ol i/C ol ifo rm s

- P la te d, S

. a ur eu s, Y ea st

M ol d, A re ob ic P la te

C ou nt , C ol ifo rm s/

E .c ol i (

S ta te W at er

, D rin ki ng

W at er

N on

-D rin ki ng

W at er

, Q ua nt ifi ca tio n)

, L ac tic A ci d, V ia bl e

M ic ro bi oa l C ou nt

(w o/

ID

, w

/ID

E nt er oc oc cu s o r Q ua nt ifi ca tio n)

M E

D

IC

A L

B io bu rd en

, L A

L

M O

L D

S po re

T ra p, B ul k

M ol d, P ar tic ul at e Id en tif ic at io n

S am pl e

V ol um e

(L

A re a

Le ng th (o r A liq uo ts

) x W id th

(o r A re a pe r A liq uo t)

M at rix C od e of

C on ta in er s

D at e C ol le ct ed m m

/d d/ yy

T im e C ol le ct ed hh :m m

ASBESTOS CHEMISTRY MICROBIOLOGY

REI will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.

Relinquished By: Date/Time: Sample Condition: Acceptable

Received By: Brett Colbert Date/Time: 09/18/2020 10:51:37 Carrier: Fed-Ex

Reservoirs Environmental, Inc Effective April 02, 2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

(303) 964-1986

(866) RESI-ENV

www.reilab.com clients.reilab.com

5801 Logan St, Suite 100, Denver, CO 80216

APPENDIX C

INSPECTOR CERTIFICATIONS

CNCC Hefley Gymnasium Limited Asbestos Inspection Report
1 INTRODUCTION
2 ASBESTOS INSPECTION
2.1 Asbestos Sampling Strategy
2.2 Asbestos Laboratory Analyses
2.3 Asbestos Chain-of-Custody
3 ASBESTOS INSPECTION RESULTS
4 CONCLUSIONS & RECOMMENDATIONS
5 QUALIFICATIONS AND LIMITATIONS
field form
473664-2

File details come from the government source that posted it. Updated .