Camp Dawson Bldg 215_Drawings.pdf

PDF 7 MB Posted

Attached to
Camp Dawson Building 215 Renovations (Construction)
Solicitation number
CRFQ 0603 ADJ2700000025 1
Issued by
Kanawha County, West Virginia

About this file

This file consists of comprehensive architectural and engineering drawings for interior renovations of Camp Dawson Building 215, located in Kingwood, West Virginia, prepared for the West Virginia Army National Guard. The project encompasses approximately 13,130 square feet of renovation work across a single-story, Type IIIB construction classified facility with a proposed height of 17 feet. The scope of work includes demolition and replacement of flooring materials, interior doors and frames, wall finishes, ceiling systems, plumbing fixtures, and mechanical/electrical systems throughout classrooms, offices, administrative areas, restrooms, and support spaces. The project involves installing new operable partition walls in five classrooms, renovating four ADA-compliant restrooms with new fixtures and finishes, and replacing HVAC equipment including five rooftop units and associated ductwork. New work includes 2'x2' LED lighting fixtures with occupancy sensors and dimming controls, updated electrical systems with branch circuits and disconnects, and comprehensive plumbing modifications. The drawings indicate the project adheres to the 2018 International Building Code, West Virginia Building Code, and 2015 International Energy Conservation Code standards.

The renovation work is distributed across multiple trade disciplines including architectural modifications, electrical installation and lighting controls, HVAC equipment replacement and distribution, and plumbing system updates. Specific deliverables shown include demolition plans, reflected ceiling plans, ADA restroom details with fixture schedules, door and window schedules, room finish schedules specifying vinyl composite tile flooring, painted concrete masonry unit walls, and acoustical ceiling tiles throughout. The project requires coordination among general contracting, mechanical, electrical, and plumbing trades, with particular attention to maintaining fire-rated wall systems, protecting existing fire alarm and emergency egress systems, and ensuring all work remains compatible with continued building occupancy. Documentation includes electrical specifications addressing conduit requirements, wiring standards, lighting fixture schedules, and grounding protocols; mechanical specifications for HVAC equipment and controls; and plumbing specifications for fixture installation and waste systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FEC

SCOPE OF WORK

CLASSROOMSOFFICES

ADMIN

MEDICAL WING

NOT IN SCOPE

SCOPE OF WORK

S

FEC

S

SS

FE-1

FE-1

FE-1

S S

S

S S S S STD 66'-2"

TD 95'-0"

LIFE SAFETY LEGEND

SYMBOL NAME/DESCRIPTION

DOOR EGRESS CAPACITY

EGRESS PATH

SINGLE -FACE EXIT SIGN

DUAL -FACE EXIT SIGN

REMOTE EMERGENCY EGRESS FIXTURE

EMERGENCY EGRESS FIXTURE; WITH DUAL HEADS

SMOKE ALARM & CARBON MONOXIDE DETECTOR

TD TRAVEL DISTANCE

FE-1 FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

S

* ALL FIXTURES AND DEVICE ARE EXISTING AND TO REMAIN. ELEC. CONTRACTOR

TO COORDINATE ANY REMOVAL / REINSTALLATION WITH G.C.

** SEE ELEC. DRAWINGS FOR MORE DETAILED INFORMATION

R

E

V

I

S

O

N

PR

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

D

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

C O

VE

R

S H

EE

T, C O

D E

AN

AL

YS

IS

AN

D D

R

AW

IN

G

IN

D

EX

TR

M

T100

OVERALL BUILDING FLOOR PLAN

SCALE: 1/16" = 1'-0"N

DRAWING INDEX

T100 COVER SHEET, CODE ANALYSIS, AND DRAWING INDEX

AD101 DEMO - FLOOR PLAN

AD102 DEMO - REFLECTED CEILING PLAN

A101 PROPOSED - FLOOR PLAN

A102 PROPOSED - REFLECTED CEILING PLAN

A103 ADA RESTROOMS, DETAILS, AND INTERIOR ELEVATIONS

A601 DOOR AND WINDOW SCHEDULES

A602 ROOM FINISH SCHEDULE

ED101 ELECTRICAL DEMOLITION PLAN

E101 NEW WORK LIGHTING PLAN

E201 ELECTRICAL DETAILS

E301 ELECTRICAL SPECIFICATIONS

HD101 HVAC DEMOLITION PLAN

H101 NEW WORK HVAC PLAN

H201 HVAC DETAILS

H202 HVAC SCHEDULES

H301 HVAC SCHEDULES

H401 HVAC SPECIFICATIONS

H402 HVAC SPECIFICATIONS

PD101 PLUMBING DEMOLITION PLAN

P101 NEW WORK PLUMBING PLAN

P201 PLUMBING SCHEDULE, NOTES, AND DETAILS

P301 PLUMBING SPECIFICATIONS

P302 PLUMBING SPECIFICATIONS

PROJECT NAME:

CAMP DAWSON BUILDING 215

LOCATION: KINGWOOD, WV

A. SCOPE OF WORK: REMODEL

B. USE GROUP CLASSIFICATION - SECTION 301

1. USE GROUP: - B

C. CONSTRUCTION CLASSIFICATION- TABLE 601

1. EXISTING CONSTRUCTION TYPE: IIIB

D. FIRE RESISTANCE RATING FOR EXTERIOR WALLS-

TABLE 602: 0

E. GENERAL BUILDING LIMITATIONS

1. HEIGHT AND AREA LIMITATIONS- TABLE 503

a. ALLOWABLE HEIGHT: 40 FT

b. ALLOWABLE # OF FLOORS: 2

c. ALLOWABLE AREA PER FLOOR: 19,000 SF

2. EXISTING

a. PROPOSED HEIGHT: 17 FT

b. PROPOSED # OF FLOORS: 1

c. PROPOSED AREA OF WORK: 13,130 SF

F. OCCUPANT LOAD- TABLE 1004.1.2

1. OCCUPANCY TYPE: B

2. SQ. FT. FLOOR AREA: 13,130 / 150 = 88

G. FIRE SUPPRESSION SYSTEM-SECTION 903:

NONE

H. STANDPIPE SYSTEM-SECTION 905:

NONE

I. FIRE ALARM SYSTEM-SECTION 907:

PROVIDED

J. STRUCTURAL DESIGN-(CHAPTER 16)

1. GOVERNING CODE: WV BUILDING CODE

2. INTERNATIONAL BUILDING CODE - IBC 2018

3. INTERNATIONAL ENERGY CONSERVATION - 2015

WEST VIRGINIA ARMY NATIONAL GUARD

CAMP DAWSON BUILDING 215, KINGWOOD WV

OWNER

WVANG CAMP DAWSON

Kingwood, WV

ARCHITECT

NEW RIVER ENGINEERS

(ARCHITECTURAL DIVISION)

507 Richland Ave, Suite 303 Athens, OH 45701

PH: 740.566.5699

CIVIL ENGINEER

NEW RIVER ENGINEERS

501 Eagle Mountain Rd.

Charleston, WV 25311

PH: 304.342.7168

STRUCTURAL ENGINEER

NEW RIVER ENGINEERS

501 EAGLE MOUNTAIN RD.

CHARLESTON, WV 25311

PH: 304.342.7168

LIFE SAFETY PLAN

SCALE: 1/16" = 1'-0"

LOCATION MAP

SCALE: NTS

N

PROJECT LOCATION

N

KINGWOOD

CAMP

DAWSON

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR

JANITOR

VENDING

EX

OFFICE

OFFICE

C.O

OFFICE

WOMEN'S

RESTROOM

MEN'S

RESTROOM

ADMIN

ADMIN

MECH.

ROOM

A/V STORAGE

STORAGE

ADMIN

CONFERENCE

OFFICE

OFFICE

OFFICE

MECH.

ROOM

VAULT

SUPPLIES

MEN'S RR

WOMEN'S

RR

JANITOR

MECH.

ROOM

A/V STORAGE

STORAGE

VESTIBULE

CORRIDOR

VESTIBULE

EX

OFFICE

OFFICE

C.O

OFFICE

EX

OFFICE

OFFICE

C.O

OFFICE

AD101

CODED AND GENERAL FLOOR PLAN DEMO NOTES

1. DEMOLITION SHALL BE LIMITED TO ITEMS INDICATED ON THE

DRAWINGS AND AS REQUIRED TO COMPLETE THE NEW WORK.

2. REMOVE AND DISPOSE OF ALL EXISTING FLOORING MATERIALS,

INCLUDING CARPET, VINYL COMPOSITION TILE (VCT), SHEET

VINYL, CERAMIC TILE, BASE, ADHESIVES, AND ASSOCIATED

ACCESSORIES IN AREAS OF WORK UNLESS NOTED OTHERWISE.

3. REMOVE AND DISPOSE OF ALL EXISTING INTERIOR DOORS,

FRAMES, HARDWARE, AND ASSOCIATED COMPONENTS AS

INDICATED ON THE DRAWINGS.

4. REMOVE AND DISPOSE OF ALL EXISTING PLUMBING FIXTURES,

ACCESSORIES, AND ASSOCIATED PIPING AS REQUIRED FOR NEW

CONSTRUCTION.

5. DEMOLISH PORTION OF WALL AS REQUIRED FOR NEW DOOR.

6. REMOVE EXISTING FOLDING PARTITION ASSEMBLIES IN THEIR

ENTIRETY, INCLUDING PANELS, TRACKS, HANGERS, OPERATING

HARDWARE, SUPPORT FRAMING, BLOCKING, AND ALL

ASSOCIATED STRUCTURAL SUPPORT MEMBERS REQUIRED FOR

THE PARTITION SYSTEM.

7. PATCH AND REPAIR FLOORS, WALLS, AND CEILINGS AFFECTED

BY REMOVAL OF FOLDING PARTITION ASSEMBLIES TO MATCH

ADJACENT CONSTRUCTION AND RECEIVE NEW FINISHES.

8. DRINKING FOUNTAIN / BOTTLE FILLER TO REMAIN

9. NO WORK IN JANITOR CLOSETS (DOOR REPLACEMENT ONLY)

10. REMOVE PTAC UNIT AND INFILL WALL, FINISHES TO MATCH

EXISTING

11. COORDINATE REMOVAL OF ELECTRICAL, MECHANICAL,

PLUMBING, AND FIRE PROTECTION COMPONENTS WITH

APPLICABLE DISCIPLINE DRAWINGS.

12. PROTECT ALL EXISTING CONSTRUCTION DESIGNATED TO

REMAIN. REPAIR OR REPLACE ANY DAMAGE RESULTING FROM

DEMOLITION OPERATIONS AT NO ADDITIONAL COST TO THE

OWNER.

13. PATCH, REPAIR, AND PREPARE ALL SURFACES AFFECTED BY

DEMOLITION TO RECEIVE NEW CONSTRUCTION AND FINISHES.

14. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING

DEMOLITION WORK AND NOTIFY THE ARCHITECT/ENGINEER OF

ANY DISCREPANCIES.

15. NO WORK IN THIS AREA.

A

AD101

B

3'-3" R.O.

DEMO

CONC.

WALL

X

6 6 6 6

6 6 6 6

7 7 7 7

2 3

2 3

2 3

2 3

2 3

2 3 2 3

2 3

2 3

2 32 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3 2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3 2 3

2 3

2 3

2 3

2 3

2 3

10 10 10 10 10 10 10 10 10

ALT #1

JANITOR

VENDING

WOMEN'S

RESTROOM

MEN'S

RESTROOM

REMOVE DOOR AND

INFILL OPENING

3' -3

" R .O

D

EM

O

C O

N C

W

AL

L

REMOVE

DOOR AND

FRAME

REMOVE

DOOR AND

FRAME

REMOVE ALL

PLUMBING FIXTURES,

PARTITIONS, AND

ACCESSORIES (TYP)

REMOVE ALL

PLUMBING FIXTURES,

PARTITIONS, AND

ACCESSORIES (TYP)

1 2

1 2

REMOVE ALL

PLUMBING FIXTURES,

PARTITIONS, AND

ACCESSORIES (TYP)

REMOVE ALL

PLUMBING FIXTURES,

PARTITIONS, AND

ACCESSORIES (TYP)

REMOVE

DOOR AND

FRAME REMOVE

DOOR AND

FRAME

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

D

EM

O

FL

O

O R

P

LA

N

TR

M

AD101

DEMO - FLOOR PLAN

SCALE: 1/8" = 1'-0"N

A

AD101

DEMO - ENLARGED RESTROOM PLAN

SCALE: 1/4" = 1'-0"

B

AD101

DEMO - ENLARGED RESTROOM PLAN

SCALE: 1/2"=1'

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR

JANITOR

VENDING

EX

OFFICE

OFFICE

C.O

OFFICE

WOMEN'S

RESTROOM

MEN'S

RESTROOM

ADMIN

ADMIN

MECH.

ROOM

A/V STORAGE

STORAGE

ADMIN

CONFERENCE

OFFICE

OFFICE

OFFICE

MECH.

ROOM

VAULT

SUPPLIES

MEN'S RR

WOMEN'S

RR

JANITOR

MECH.

ROOM

A/V STORAGE

STORAGE

VESTIBULE

BEHAVIORAL

HEALTH

LAB

CORRIDOR

TOILET

VESTIBULE

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2

R2R2R2R2R2R2

R2

R2

R2

R2

R2

R2

R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2R2

R2

R2

R2

R2

R2

R2

R2 R2 R2

R2 R2

R2 R2

R2 R2

R2R2

R2R2

R2R2

R2R2

EX

OFFICE

OFFICE

C.O

OFFICE

R2

R2

R2

R2

R2

EX

OFFICE

OFFICE

C.O

OFFICE

R2

R2

R2

R2

R2 R2 R2

R2 R2

R2 R2

R2 R2

REFLECTED CEILING PLAN DEMO NOTES

1. REMOVE AND DISPOSE OF ALL EXISTING 2'-0" x 4'-0" ACOUSTICAL

CEILING TILES (ACT) IN AREAS OF WORK.

2. REMOVE EXISTING 2'-0" x 4'-0" LIGHT FIXTURE IN AREAS OF WORK

3. SALVAGE EXISTING SUSPENDED CEILING GRID. CONTRACTOR

SHALL INSPECT GRID AND REPAIR OR REPLACE DAMAGED,

DEFLECTED, OR UNSERVICEABLE COMPONENTS AS REQUIRED.

4. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES FOR

REQUIRED ABOVE CEILING HEIGHT FOR NEW DUCT WORK.

5. COORDINATE CEILING GRID MODIFICATIONS WITH LIGHTING,

HVAC, FIRE PROTECTION, AND OTHER CEILING-MOUNTED

DEVICES.

6. REMOVE ALL LIGHT FIXTURES, HVAC FIXTURES, CEILING TILES

AND GRID. PREPARE AREA FOR ALL NEW FIXTURES, CEILING

TILES AND GRID.

7. NO WORK THIS AREA

AD102

A

AD102

B

X

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

3 1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

JANITOR

VENDING

WOMEN'S

RESTROOM

MEN'S

RESTROOM

1 2

1 2

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

D

EM

O

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

TR

M

AD102

DEMO - REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"N

A

AD102

DEMO - ENLARGED RESTROOM RCP

SCALE: 1/2"=1'

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR

JANITOR

VENDING

107 EX OFFICE

OFFICE

C.O. OFFICE

WOMEN'S

RESTROOM

MEN'S

RESTROOM

EX OFFICE

ADMIN

C.O. OFFICE

OFFICE

C.O. OFFICE

OFFICE

EX OFFICE

ADMIN

MECH.

ROOM

A/V STORAGE

STORAGE

ADMIN

CONFERENCE

OFFICE

OFFICE

OFFICE

MECH.

ROOM

VAULT

SUPPLIES

MEN'S RR

WOMEN'S

RR

JANITOR

MECH.

ROOM

A/V STORAGE

STORAGE

VESTIBULE

BEHAVIORAL

HEALTH

LAB

CORRIDOR

VESTIBULE

24'-31 2"

83'-4 12 "

'-4

49'-0 12 "

'-3

1 2"

31'-2"

'-4

1 2"

32'-4"

'-4

1 2"

31'-2"

'-3

1 2"

22'-71 2"

140'-10"

'-5

1 2"

10'-111 2"

9' -4

10'-71 2"

8'-7"

8"

11'-0"

'-9

7' -1

1"

'-8

'-1

1 2"

19'-11 2"

'-9

7'

-9

9' -5

'-1

0"

89'-6" 25'-01 2"

'-1

11 2" 6'

-1

'-1

11 2"

8'-1"

19'-4 12 "

'-8

8'-8 12 "

12'-0 12 "

'-4

6'-8 12 "

8'-2 12 "

12'-8 12 "

'-0

2"

9'-11 12 "

'-1

8'-2"

6' -2

'-9

20'-71 2"

'-0

1 2"

33'-1"

FEC

FE-1

FE-1

FE-1

'-1

1 2"

10'-9" 19'-11 2"

7'-11" 4'-1"

4'-

2"

'-8

1 2"

'-9

7'

-8

9' -6

10'-81 2"

'-1

1 2"

19'-11 2"

'-8

90'-5 12 "

21'-4"

'-1

1 2"

36'-3"

'-4 1 2"

42'-4"

5'-0"

TYP

5'-0"

TYP

5'- 0"

TYP

5'-0"

TYP

'-4

1 2"

31'-11 2"

21'-1"

5' -0

TY

P

117'-5"

'-6

5'-0"

TYP

'-0

'-1 1 2"

12'-6"

'-1 1 2"

CODED AND GENERAL FLOOR PLAN NOTES

1. ALL NEW WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE

ARCHITECTURAL DRAWINGS, ROOM FINISH SCHEDULE, AND ENLARGED PLANS.

CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD

PRIOR TO INSTALLATION.

2. INSTALL NEW FLOOR FINISHES THROUGHOUT AREAS OF WORK AS INDICATED

IN THE ROOM FINISH SCHEDULE. FLOORING SHALL INCLUDE ALL REQUIRED

PREPARATION, LEVELING, TRANSITIONS, AND ACCESSORIES.

3. INSTALL NEW WALL BASE THROUGHOUT ALL FINISHED AREAS AS INDICATED IN

THE ROOM FINISH SCHEDULE AND DETAILS.

4. PREPARE AND PAINT ALL NEW AND EXISTING WALLS SCHEDULED TO RECEIVE

FINISHES. PAINTING SHALL INCLUDE ALL REQUIRED PRIMING, PATCHING, AND

SURFACE PREPARATION FOR A COMPLETE AND UNIFORM FINISH.

5. PROVIDE AND INSTALL NEW INTERIOR DOORS, FRAMES, AND HARDWARE AS

INDICATED ON THE DOOR SCHEDULE AND FLOOR PLANS.

6. PROVIDE AND INSTALL NEW FOLDING PARTITION WALL SYSTEMS COMPLETE

WITH PANELS, TRACKS, SUPPORT STRUCTURE, HARDWARE, AND ALL

REQUIRED ACCESSORIES. COORDINATE INSTALLATION WITH STRUCTURAL

AND CEILING SYSTEMS.

7. RENOVATE EXISTING RESTROOMS AS INDICATED ON THE ENLARGED PLANS.

WORK SHALL INCLUDE ALL NEW FINISHES, FIXTURES, ACCESSORIES, AND

ASSOCIATED PLUMBING AND ELECTRICAL WORK AS REQUIRED FOR A

COMPLETE INSTALLATION.

8. ALL FINISHES SHALL BE IN ACCORDANCE WITH THE ROOM FINISH SCHEDULE.

ANY DISCREPANCIES BETWEEN PLANS AND SCHEDULE SHALL BE BROUGHT TO

THE ARCHITECT’S ATTENTION PRIOR TO INSTALLATION.

9. CONTRACTOR SHALL COORDINATE ALL ARCHITECTURAL WORK WITH

MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS TO ENSURE PROPER

INTEGRATION OF ALL SYSTEMS.

10. PROTECT ALL FINISHES AND BUILDING COMPONENTS DURING CONSTRUCTION.

ANY DAMAGE SHALL BE REPAIRED OR REPLACED TO MATCH ADJACENT WORK.

11. CONTINUOUS EXPANSION JOINT BETWEEN SIDEWALK AND BUILDING

12. NEW DOOR OPENING (REFER TO DOOR SCHEDULE)

13. INFILL EXISTING OPENING. MATCH EXISTING

14. EXISTING DOOR AND FRAME TO BE REMOVED - PROVIDE FINISHED MASONRY

OPENING

15. NO WORK THIS AREA

16. ALL EXISTING FLOOR OUTLETS TO REMAIN

17. COORDINATE SIDEWALK WITH HVAC CONDENSING UNITS

A103

A103

115 116 117 118 119

123 124 125

138 129

122A

A101 1/2

A101

1/2

A101 1/2

X

6 6 6 6

11 11

A A101

A A A A A

B

BB

B

C

CONTROL JOINT

(APPROX. 5'-6" O.C.)

COMPACTED

SUBGRADE

(APPROX. 30'-0" O.C.)

EXPANSION JOINT

1/4"R

SUBGRADE

COMPACTED

CONCRETE

3/8" PREMOLDED

EXPANSION JOINT

MATERIAL, CAULK

@ PARKING AREA

HAND TOOLED JOINT,

1/4"R X 1/2" DEEP,

CAULK @ PARKING

AREA

CONCRETE

OPERABLE

PARTITION

(TYP)

OPERABLE

PARTITION -

INTEGRAL

MAN DOOR

OPERABLE

PARTITION

ENCLOSURE

7'

SOFFIT

HT.

7'-6"

ACT HT.

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

PR

O

PO

SE

D

FL

O

O R

P

LA

N

TR

M

A101

PROPOSED - FLOOR PLAN

SCALE: 1/8" = 1'-0"N

A A101

ELEVATION - OPERABLE PARTITION W/ MAN DOOR

SCALE: 1/4"=1'

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR

JANITOR

VENDING

107 EX OFFICE

OFFICE

C.O. OFFICE

WOMEN'S

RESTROOM

MEN'S

RESTROOM

EX OFFICE

ADMIN

C.O. OFFICE

OFFICE

C.O. OFFICE

OFFICE

EX OFFICE

ADMIN

MECH.

ROOM

A/V STORAGE

STORAGE

ADMIN

CONFERENCE

OFFICE

OFFICE

OFFICE

MECH.

ROOM

VAULT

SUPPLIES

MEN'S RR

WOMEN'S

RR

JANITOR

MECH.

ROOM

A/V STORAGE

STORAGE

VESTIBULE

BEHAVIORAL

HEALTH

LAB

CORRIDOR

VESTIBULE

S

FEC

S

SS

S S

S

S S S S S

REFLECTED CEILING PLAN NOTES

1. PROVIDE NEW SUSPENDED CEILING MODIFICATIONS AS REQUIRED TO

ACCOMMODATE NEW LAYOUT, INCLUDING INSTALLATION OF

ADDITIONAL CROSS TEES TO CONVERT EXISTING OR NEW GRID

SYSTEM TO 2'-0" x 2'-0" MODULES.

2. REPAIR, CLEAN, AND PAINT EXISTING CEILING GRID SYSTEM WHERE

EXPOSED. PAINT SHALL BE A UNIFORM FINISH THROUGHOUT ALL

EXPOSED GRID AREAS UNLESS NOTED OTHERWISE.

3. INSTALL NEW 2'-0" x 2'-0" ACOUSTICAL CEILING TILES (ACT) IN ALL

AREAS INDICATED. CEILING TILES SHALL MATCH SPECIFIED ROOM

FINISH SCHEDULE AND BE INSTALLED IN NEW AND MODIFIED GRID

SYSTEM.

4. PROVIDE AND INSTALL NEW 2'-0" x 2'-0" LED LIGHT FIXTURES AS

INDICATED ON THE REFLECTED CEILING PLAN AND ELECTRICAL

DRAWINGS. COORDINATE EXACT LOCATIONS WITH CEILING GRID

LAYOUT AND OTHER CEILING-MOUNTED DEVICES.

5. COORDINATE ALL CEILING WORK WITH MECHANICAL, ELECTRICAL, FIRE

PROTECTION, AND OTHER TRADE INSTALLATIONS PRIOR TO

INSTALLATION OF CEILING TILES.

6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF

WORK. NOTIFY ARCHITECT OF ANY CONDITIONS THAT MAY IMPACT

CEILING GRID MODIFICATIONS OR LIGHT FIXTURE INSTALLATION.

7. ALL NEW FIXTURES, CEILING TILES AND GRID. NEW CEILING

HEIGHT 7'-6" A.F.F. THIS AREA ONLY

8. NEW GYP. BD. SOFFIT - SEE DETAIL THIS SHEET

9. NO WORK THIS AREA

10. ADD CROSS T, PAINT EXISTING GRID, TYP - UNO

11. ALL EXISTING SUPPLY AND RETURN DIFFUSERS TO BE REPLACED - UNO.

CONTRACTOR TO VERIFY FINAL LOCATION WITH NEW ACT LAYOUT.

12. REPLACE EXISTING AHU IN ATTIC SPACE. REFER TO MECH. DWGS.

AD102

A

AD102

B

A102 A

A102 A

A102 A

A102 A

77777

8 8 8 8

121212

REFLECTED CEILING LEGEND

SYMBOL NAME/DESCRIPTION

NEW 2'x2' LAY-IN LED LIGHT

NEW 1'x4' SURFACE MOUNTED LED LIGHT

EXISTING SINGLE -FACE EXIT SIGN

EXISTING DUAL -FACE EXIT SIGN

EXISTING REMOTE EMERGENCY EGRESS FIXTURE

EXISTING EMERGENCY EGRESS FIXTURE; WITH DUAL HEADS

EXISTING SMOKE ALARM & CARBON MONOXIDE DETECTOR

NEW 2'x2' LAY-IN SUPPLY GRILLE

NEW 2'x2' LAY-IN RETURN GRILLE

S

* ALL FIRE ALARM / EGRESS FIXTURES AND DEVICE ARE EXISTING AND TO REMAIN.

ELEC. CONTRACTOR TO COORDINATE ANY REMOVAL / REINSTALLATION WITH G.C.

** SEE ELEC. DRAWINGS FOR MORE DETAILED INFORMATION

Fi ni sh ed fl oo r t o un de rs id e of c ei lin g

25 mm [1"]

100 mm [4"]

50 mm [2"]

Finished floor

EXISTING TRUSS (BEYOND)

GYP. BD. SOFFIT

7'-0" A.F.F.

EXISTING WOOD BEAM

OPERABLE PARTITION WALL

7'-6" A.F.F.

2x4 WD. FRAMING (TYP)

BASIS OF DESIGN:

MODERNFOLD

Acousti-Seal® Legacy®

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

PR

O

PO

SE

D

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

W M

A102

PROPOSED - REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"N

A A102

DETAIL

SCALE: 1 1/2"=1'

VITREOUS CHINATOILETCIMARRONK-3619 VITREOUS CHINATOILETCIMARRONK-3619

VITREOUS CHINATOILETCIMARRONK-3619

VITREOUS CHINATOILETCIMARRONK-3619

VITREOUS CHINATOILETCIMARRONK-3619

VITREOUS CHINABATHROOM SINKCAXTONK-20000

VITREOUS CHINABATHROOM SINKCAXTONK-20000

VITREOUS CHINABATHROOM SINKCAXTONK-20000

VITREOUS CHINABATHROOM SINKCAXTONK-20000

4' SIDE

APPROACH

4' SIDE

APPROACH

48x30 CLEAR

FLOOR SPACE

48x30 CLEAR

FLOOR SPACE

5'

5'

5'

3' -1

1"

5'-0"4'-0"

3'-11"

5' -0

4'

-0

NEW 3'-0" x

6'-8" DOOR

3' -3

" R .O

3'-3"

CONC.

BLOCK

INFILL

3'-33 8"

R.O.

3'-23 8"

R.O.

REMOVE DOOR AND

FRAME OPENING

REMOVE DOOR AND

INFILL OPENING

WOMEN'S

RESTROOM

MEN'S

RESTROOM

REMOVE DOOR AND

FRAME OPENING

J

K

M

N

A103 P

Q

R

S

A103

30" CLR

F.F. 17 " m ax

HANDICAP ACCESSIBLE TOILETHANDICAP ACCESSIBLE URINAL

ELONGATED

RIM

HANDICAP ACCESSIBLE LAVATORY

ADA LEVER TYPE

HANDLES ON FAUCET

17" min

8" minKNEE CLEARANCE

INSULATE EXPOSED

DRAIN & PIPING

" m ax

" m ax

" m in

9" m in

" m in

6" max TOE CLEARANCE

F.F.

" m in

" m ax

30" min

MIRROR

"m in T

AN

K

TO

IL

ET

"m in

F

LU

SH

V

. T O

IL

ET

60" MIN.

2" min

" m ax

BACK WALL18"

" m in

" m ax

36"

" m in

" m ax

TOILET

PAPER

SIDE WALL

" m in

" m ax

42" min12" 54" min

" m in 39 " m in

" m ax

39" min 41" max

24" 18"

TOILET PAPER -

REFER ELEVATION

FOR MOUNTING

LOCATION

VITREOUS CHINATOILETCIMARRONK-3619 VITREOUS CHINATOILETCIMARRONK-3619

48x30 CLEAR

FLOOR SPACE

48x30 CLEAR

FLOOR SPACE

56x60 CLEAR

FLOOR SPACE

56x60 CLEAR

FLOOR SPACE

3'-11"

5' -0

4'

-0

4'-5"

3'-11"

5' -0

4'

-0

4'-5"

DEMO BLOCK WALL

AND REPLACE WITH

2x6 WALL.

MEN'S RR

WOMEN'S

RR

A

B

C

D

A103 E

F

G

H

A103

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

6' -8

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

6' -8

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

MODELNUMBERTRADENAMEPRODUCTMATERIAL

6' -8

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

K-3324KATHRYNTOILETVITREOUS CHINA

6' -8

MODELNUMBERTRADENAMEPRODUCTMATERIAL

3'

3'

3'

3'

6' -8

3'

6' -8

3'

8'

17'-91 8"

8'

10'-113 4"

8'

17'-91 8"

8'

10'-113 4"

8'

17'-91 2"

8'

11'-01 4"

8'

17'-91 2"

8'

11'-01 4"

8'

8'-81 2"

8'

5'-111 8"

8'

8'-81 2"

8'

5'-111 8"

8'

8'-81 2"

8'

5'-111 8"

8'

8'-81 2"

8'

5'-111 8"

PLUMBING / GAS EQUIPMENT SCHEDULE

SYMBOL DESCRIPTION MANUFACTURER MODEL NUMBER SIZE

TOILET AMERICAN STANDARD 747AA.107SC 30-1/4" x 17-5/16" x 31"

RESTROOM LAV AMERICAN STANDARD 0355.015 14 78" x 10" x 6 12"

RESTROOM FAUCET AMERICAN STANDARD 5502.170 11 34" x 4" x 2 34"

42" GRAB BAR BOBRICK B-6806 x 42 1-1/2" x 42"

18" GRAB BAR BOBRICK B-6806 x 18 1-1/2" x 18"

36" GRAB BAR BOBRICK B-6806 x 36 1-1/2" x 36"

SOAP DISPENSER BOBRICK B-2012

PAPER TOWEL

DISPENSER BOBRICK B-9262

TISSUE DISPENSER BOBRICK B-265

HAND DRYER EXCEL DRYER XL-SB-ECO

VITREOUS CHINABATHROOM SINKCAXTONK-20000

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

AD

A

R

ES

TR

O

O M

S, D

ET

AI

LS

AN

D

IN

TE

R

IO

R E

LE

VA

TI

O

N S

TR

M

A103

A103

ENLARGED - CLASSROOM ADA RESTROOM PLAN

SCALE: 1/2" = 1'-0"

A103

ENLARGED - OFFICE ADA RESTROOM PLAN

SCALE: 1/2" = 1'-0"

A A103

ELEVATION A

SCALE: 1/4"=1'

B A103

ELEVATION B

SCALE: 1/4"=1'

C A103

ELEVATION C

SCALE: 1/4"=1'

D A103

ELEVATION D

SCALE: 1/4"=1'

E A103

ELEVATION E

SCALE: 1/4"=1'

F A103

ELEVATION F

SCALE: 1/4"=1'

G A103

ELEVATION G

SCALE: 1/4"=1'

J A103

ELEVATION J

SCALE: 1/4"=1'

L A103

ELEVATION L

SCALE: 1/4"=1'

M A103

ELEVATION M

SCALE: 1/4"=1'

N A103

ELEVATION N

SCALE: 1/4"=1'

P A103

ELEVATION P

SCALE: 1/4"=1'

Q A103

ELEVATION Q

SCALE: 1/4"=1'

R A103

ELEVATION R

SCALE: 1/4"=1'

S A103

ELEVATION S

SCALE: 1/4"=1'

H A103

ELEVATION H

SCALE: 1/4"=1'

AutoCAD SHX Text

CLEAR FLOOR SPACE @ DRINKING FOUNTAIN AND LAVATORY

AutoCAD SHX Text

CLEAR AREA

AutoCAD SHX Text

CLEAR FLOOR SPACE @ TOILET

AutoCAD SHX Text

CLEAR AREA

AutoCAD SHX Text

SECTION @ URINAL

FRONT

DOOR SCHEDULE

DOOR FRAME

COMMENTS

No. TYPE SIZE MAT. FINISH TYPE MAT. FINISH HDW

101 A 3'-8" x 7'-0" HM PT HM PT H6 REPLACE

102 V 3'-0" x 7'-0" HM PT HM PT H6 VAULT DOOR ALT #1

103 B 3'-0" x 7'-0" HM PT HM PT H6 REPLACE

104 B 3'-0" x 7'-0" HM PT HM PT H6 REPLACE

105 C 3'-0" x 7'-0" HM PT HM PT H4 REPLACE

106 C 3'-0" x 7'-0" HM PT HM PT H4 REPLACE

107 C 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

108 C 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

109 C 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

110 H 3'-0" x 7'-0" HM PT HM PT H2 REPLACE

111 B 3'-0" x 7'-0" HM PT HM PT H5 REPLACE

112 B 3'-0" x 7'-0" HM PT HM PT H5 REPLACE

113 F 6'-0" x 7'-0" HM PT HM PT H10 DOUBLE DOOR

114 E 6'-0" x 7'-0" HM PT HM PT H1 DOUBLE DOOR

115 B 3'-0" x 7'-0" HM PT HM PT H7 REPLACE

116 B 3'-0" x 7'-0" HM PT HM PT H7 REPLACE

117 B 3'-0" x 7'-0" HM PT HM PT H7 REPLACE

118 B 3'-0" x 7'-0" HM PT HM PT H7 REPLACE

119 B 3'-0" x 7'-0" HM PT HM PT H7 REPLACE

120 B 3'-0" x 7'-0" HM PT HM PT H5 REPLACE

121 B 3'-0" x 7'-0" HM PT HM PT H10 REPLACE

122 F 6'-0" x 7'-0" HM PT HM PT H10 DOUBLE DOOR

122A F 3'-0" x 7'-0" HM PT HW PT H11 NEW DOOR

123 D 3'-4" x 7'-0" HM PT HM PT H7 REPLACE

124 B 3'-0" x 7'-0" HM PT HM PT H8 REPLACE

125 B 3'-0" x 7'-0" HM PT HM PT H5 REPLACE

126 B 3'-0" x 7'-0" HM PT HM PT H8 NEW DOOR

127 D 3'-4" x 7'-0" HM PT HM PT H2 REPLACE

128 E 6'-0" x 7'-0" HM PT HM PT H1 DOUBLE DOOR

129 B 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

130 B 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

131 B 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

132 D 3'-0" x 7'-0" HM PT HM PT H7 REPLACE

133 B 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

134 B 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

135 G 3'-4" x 7'-0" HM PT HM PT H9 REPLACE

136 D 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

137 D 3'-0" x 7'-0" HM PT HM PT H5 REPLACE

138 D 3'-0" x 7'-0" HM PT HM PT H9 REPLACE

139 D 3'-0" x 7'-4" HM PT HM PT H3 MASONRY OPENING (PREVIOUS DOOR AND FRAME REMOVED)

140 D 3'-0" x 7'-4" HM PT HM PT H3 MASONRY OPENING (PREVIOUS DOOR AND FRAME REMOVED)

WINDOW SCHEDULE

No.

WINDOW FRAME

COMMENTS

SIZE OPERATION AMOUNT MAT. FINISH

A 1'-4" x 6'-8" NON-OPERABLE 5 STEEL PT EXISTING

B 1'-10" x 6'-8" NON-OPERABLE 4 STEEL PT EXISTING

C 3'-0" x 6'-8" NON-OPERABLE 1 STEEL PT EXISTING

1. ALL WINDOWS TO BE INSTALLED

ACCORDING TO MANUFACTURER

INSTRUCTIONS.

2. ALL EXTERIOR TO REMAIN

3. REFER TO PLAN FOR LOCATIONS

4. CONTRACTOR TO VERIFY ALL EXISTING

WINDOW, FRAME, AND OPENING

DIMENSIONS.

WINDOW SCHEDULE NOTES: WINDOW TYPES:

1. ALL DOORS TO BE INSTALLED ACCORDING TO

MANUFACTURER INSTRUCTIONS.

2. CONTRACTOR TO VERIFY ALL EXISTING DOOR, FRAME, AND

OPENING DIMENSIONS.

3. ALL INTERIOR DOORS AND FRAMES TO BE REPLACED WITH

SAME SIZE, UNLESS NOTED OTHERWISE

4. ALL EXTERIOR DOORS TO REMAIN

DOOR SCHEDULE NOTES:

DOOR TYPES:

1'-4"

6' -8

WINDOW TYPE "A"

-FIXED

-NON-OPERABLE

1'-10"

6' -8

WINDOW TYPE "B"

-FIXED

-NON-OPERABLE

7' -0

3'-8"

DOOR TYPE "A"

-INTERIOR

-SINGLE DOOR

-HOLLOW METAL

7' -0

3'-0"

DOOR TYPE "B"

-INTERIOR

-SINGLE DOOR

-HOLLOW METAL

2'-4"

DOOR TYPE "C"

-INTERIOR

-SINGLE DOOR

-HOLLOW METAL

DOOR TYPE "D"

-INTERIOR

-SINGLE DOOR

-HOLLOW METAL

7' -0

3'-0"

7' -0

DOOR TYPE "E"

-INTERIOR

-DOUBLE DOOR

-HOLLOW METAL

DOOR TYPE "F"

-INTERIOR

-DOUBLE DOOR

-HOLLOW METAL

DOOR TYPE "G"

-EXTERIOR

-SINGLE DOOR

-HOLLOW METAL

7' -0

3'-4"

REFER TO SPECIFICATIONS

GENERAL HARDWARE NOTES:

1. ALL HARDWARE TO BE INSTALLED ACCORDING TO

MANUFACTURER INSTRUCTIONS.

3'-0"

DOOR TYPE "H"

-INTERIOR

-SINGLE DOOR

-HOLLOW METAL

7' -0

3'-0"

6' -8

WINDOW TYPE "C"

-FIXED

-NON-OPERABLE

7' -4

7' -4

7' -4

7' -4

FRAME TYPE "1"

-INTERIOR

-HOLLOW METAL

FRAME TYPE "2"

-INTERIOR

-HOLLOW METAL

FRAME TYPE "3"

-INTERIOR

-HOLLOW METAL

FRAME TYPE "7"

-INTERIOR

-DOUBLE DOOR

-HOLLOW METAL

7' -4

FRAME TYPE "4"

-INTERIOR

-HOLLOW METAL

7' -4

FRAME TYPE "5"

-INTERIOR

-HOLLOW METAL

DOOR HARDWARE:

7' -4

FRAME TYPE "6"

-INTERIOR

-HOLLOW METAL

3'-0"

DOOR TYPE "V"

-INTERIOR

-VAULT DOOR

-STEEL

-ALT #1

7' -0

7' -0

7' -0

6'-0"6'-0"

3'-8" 3'-8" 3'-8" 3'-0"1'-8" 3'-0"3'-0" 6'-0"1'-8" 1'-8" 6'-0"

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

D O

O R

A N

D W

IN

D

O W

S C

H

ED

U

LE

W M

A601

ROOM FINISH SCHEDULE

No. ROOM NAME

FLOOR BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING COMMENTS

MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH HEIGHT

100 VESTIBULE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

101 CORRIDOR CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

102 ADMIN CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

103 EX OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

104 OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

105 C.O. OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

106 ADMIN CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

107 VENDING CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

108 WOMEN'S RESTROOM CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

109 JANITOR CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" NO WORK

110 MEN'S RESTROOM CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

111 EX OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

112 OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

113 C.O. OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

114 C.O. OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

115 OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

116 EX OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

117 ADMIN CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

118 CONFERENCE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

119 OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

120 WOMEN'S RESTROOM CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

121 MEN'S RESTROOM CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

122 JANITOR CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" NO WORK

123 SUPPLIES CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

124 VAULT CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" NO WORK

125 MECH. ROOM CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

126 OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

127 OFFICE CONC. CPT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

128 STORAGE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

129 AV STORAGE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

130 STORAGE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

131 CLASSROOM CONC. CPT VCB -- CMU PT OP MNFR CMU PT CMU PT ACT PT 7'-6" NEW OPERABLE PARTITIONS

132 CLASSROOM CONC. CPT VCB -- CMU PT OP MNFR CMU PT OP MNFR ACT PT 7'-6" NEW OPERABLE PARTITIONS

133 CLASSROOM CONC. CPT VCB -- CMU PT OP MNFR CMU PT OP MNFR ACT PT 7'-6" NEW OPERABLE PARTITIONS

134 CLASSROOM CONC. CPT VCB -- CMU PT OP MNFR CMU PT OP MNFR ACT PT 7'-6" NEW OPERABLE PARTITIONS

135 CLASSROOM CONC. CPT VCB -- CMU PT CMU PT CMU PT OP MNFR ACT PT 7'-6" NEW OPERABLE PARTITIONS

136 MECH ROOM CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

137 AV STORAGE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

138 STORAGE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

139 VESTIBULE CONC. VCT VCB -- CMU PT CMU PT CMU PT CMU PT ACT PT 8'-6" --

ACT ACOUSTIC CEILING TILES ARMSTRONG WORLD INDUSTRIES, INC; ULTIMA LAY-IN OR APPROVED EQUAL

CPT CARPET TILE BLOCKADE MANUFACTURED BY TARKETT OR APPROVED EQUAL

DW GYPSUM DRYWALL AMERICAN GYPSUM COMPANY OR APPROVED EQUAL

PT PAINT SHERWIN-WILLIAMS OR APPROVED EQUAL

MNFR MANUFACTURE

VCB VINYL COVE BASE ARMSTRONG WORLD INDUSTRIES OR APPROVED EQUAL

VCT VINYL COMPOSITE TILE ARMSTRONG WORLD INDUSTRIES OR APPROVED EQUAL

OP OPERABLE PARTITION WALL

CMU CONCRETE MASONRY BLOCK

ABBREVIATIONS:

FLOORING: VINYL COMPOSITE TILES

WALL: PAINTED CMU / GYPSUM BOARD

CEILING: 2'x4' LAY-IN ACOUSTICAL TILE

EXISTING FINISHES:

1. ALL FINISHES SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS / STANDARDS.

2. ALL EXISTING FINISHES SHALL BE REMOVED, UNLESS NOTED OTHERWISE

3. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING

DEMOLITION / NEW WORK AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

GENERAL NOTES: R

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

| 7

-0

AU

G U

ST

0, S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

OF

STATE

NO.1859

AINIGRIVTSE

W

DERETSIGE

R

TCETIHCRADERETSI

GE

R

L E

ON

ENEGUELEAHCI

M

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

R O

O M

F

IN

IS

H

S C

H

ED

U

LE

TR

M

A602

H

T

L

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

Au gu st

, 2

S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ED101

EL

EC

TR

IC

AL

D

EM

O

LI

TI

O N

P

LA

N

AutoCAD SHX Text Dublin, Ohio 43016

AutoCAD SHX Text 6130 Wilcox Road

AutoCAD SHX Text

PRATER

AutoCAD SHX Text Engineering Associates, Inc.

AutoCAD SHX Text

(614) 766 4896

AutoCAD SHX Text praterengineering.com

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

JOB NUM.

AutoCAD SHX Text 26003

AutoCAD SHX Text P

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text H

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text

DOUGLAS L.

AutoCAD SHX Text

POWELL

AutoCAD SHX Text E-57325

AutoCAD SHX Text 08/05/26

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

ELECTRICAL DEMOLITION PLAN

AutoCAD SHX Text 1/8"=1'-0"

AutoCAD SHX Text

ED101-26003.DWG

AutoCAD SHX Text

N. RUSSELL

AutoCAD SHX Text

N. RUSSELL

AutoCAD SHX Text

T. LEYKAUF

AutoCAD SHX Text

DEMOLISH EXISTING HVAC UNIT AND RECEPTACLE (TYP OF 10).

AutoCAD SHX Text

CODED NOTES

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text A. SALVAGE EXISTING LIGHTING CIRCUIT OF ALL DEMOLISHED LIGHTING FIXTURES, TO SALVAGE EXISTING LIGHTING CIRCUIT OF ALL DEMOLISHED LIGHTING FIXTURES, TO BE REUSED FOR REPLACEMENT LIGHTING FIXTURES ON SHEET E101. B. UNLESS NOTED OTHERWISE, REMOVE ALL WIRE AND CONDUIT FROM DEMOLISHED UNLESS NOTED OTHERWISE, REMOVE ALL WIRE AND CONDUIT FROM DEMOLISHED WIRING DEVICES BACK TO SOURCE OR NEXT UPSTREAM EQUIPMENT TO REMAIN. MAKE JUNCTIONS AND EXTEND CIRCUITRY TO MAINTAIN POWER AND CONTROL TO ALL DOWNSTREAM EQUIPMENT TO REMAIN. REMOVE ALL ASSOCIATED UNUSED PATHWAYS AND HARDWARE. C. UNLESS NOTED OTHERWISE, FIRE ALARM SYSTEM IS EXISTING TO REMAIN. MAINTAIN UNLESS NOTED OTHERWISE, FIRE ALARM SYSTEM IS EXISTING TO REMAIN. MAINTAIN AND PROTECT ACTIVE DEVICES TO PREVENT INADVERTENT BUILDING EVACUATION. D. ALL ELECTRICAL EQUIPMENT, WIRING DEVICES, EQUIPMENT, ETC. SHOWN ON THIS ALL ELECTRICAL EQUIPMENT, WIRING DEVICES, EQUIPMENT, ETC. SHOWN ON THIS LL ELECTRICAL EQUIPMENT, WIRING DEVICES, EQUIPMENT, ETC. SHOWN ON THIS PLAN IN THIN LINES AND SUBSCRIPT "E" ARE EXISTING TO REMAIN AND SHOWN FOR REFERENCE ONLY. . E. WHERE MECHANICAL EQUIPMENT IS TO BE REMOVED, THIS CONTRACTOR SHALL WHERE MECHANICAL EQUIPMENT IS TO BE REMOVED, THIS CONTRACTOR SHALL HERE MECHANICAL EQUIPMENT IS TO BE REMOVED, THIS CONTRACTOR SHALL DISCONNECT AND REMOVE ALL ASSOCIATED ELECTRICAL DEVICES AND ELECTRICAL CONNECTIONS BACK TO THE SOURCE OR LAST ACTIVE JUNCTION BOX. THIS CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR PRIOR TO DEMOLITION.

AutoCAD SHX Text

1. DEMOLISH EXISTING FURNACE. SALVAGE AND MAINTAIN EXISTING WIRING AND DEMOLISH EXISTING FURNACE. SALVAGE AND MAINTAIN EXISTING WIRING AND DISCONNECT FOR REPLACEMENT FURNACE IN PLACE. SEE SHEET E101. 2. DEMOLISH EXISTING AIR HANDLER IN ATTIC. SALVAGE AND MAINTAIN EXISTING DEMOLISH EXISTING AIR HANDLER IN ATTIC. SALVAGE AND MAINTAIN EXISTING WIRING FOR RECONNECTION TO NEW AIR HANDLER IN PLACE. 3. DEMOLISH EXISTING AIR CONDENSER AND ASSOCIATED DISCONNECT. SALVAGE DEMOLISH EXISTING AIR CONDENSER AND ASSOCIATED DISCONNECT. SALVAGE CONDUIT AND WIRING FOR REPLACEMENT AIR CONDENSER AND DISCONNECT.

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

Au gu st

, 2

S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 E101

N

EW

W O

R K

LI

G

H

TI

N G

P

LA

N

AutoCAD SHX Text Dublin, Ohio 43016

AutoCAD SHX Text 6130 Wilcox Road

AutoCAD SHX Text

PRATER

AutoCAD SHX Text Engineering Associates, Inc.

AutoCAD SHX Text

(614) 766 4896

AutoCAD SHX Text praterengineering.com

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

JOB NUM.

AutoCAD SHX Text 26003

AutoCAD SHX Text P

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text H

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text

DOUGLAS L.

AutoCAD SHX Text

POWELL

AutoCAD SHX Text E-57325

AutoCAD SHX Text 08/05/26

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

BATHROOM SINK

AutoCAD SHX Text

CAXTON

AutoCAD SHX Text K-20000

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

BATHROOM SINK

AutoCAD SHX Text

CAXTON

AutoCAD SHX Text K-20000

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

BATHROOM SINK

AutoCAD SHX Text

CAXTON

AutoCAD SHX Text K-20000

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

BATHROOM SINK

AutoCAD SHX Text

CAXTON

AutoCAD SHX Text K-20000

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

CIMARRON

AutoCAD SHX Text K-3619

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NEW WORK ELECTRICAL PLAN

AutoCAD SHX Text 1/8"=1'-0"

AutoCAD SHX Text

E101-26003.DWG

AutoCAD SHX Text

N. RUSSELL

AutoCAD SHX Text

N. RUSSELL

AutoCAD SHX Text

T. LEYKAUF

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text 60/2,3R

AutoCAD SHX Text 60/2,3R

AutoCAD SHX Text 60/2,3R

AutoCAD SHX Text 60/2,3R

AutoCAD SHX Text 60/2,3R

AutoCAD SHX Text

RTU-1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text

RTU-2

AutoCAD SHX Text

RTU-3

AutoCAD SHX Text

RTU-4

AutoCAD SHX Text

RTU-5

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

OS

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

OS

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

OS

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

CODED NOTES

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text A. ALL LIGHT FIXTURES, WIRING DEVICES, ETC. SHOWN ON THIS PLAN IN BOLD SOLID ALL LIGHT FIXTURES, WIRING DEVICES, ETC. SHOWN ON THIS PLAN IN BOLD SOLID LINES ARE NEW UNLESS NOTED OTHERWISE. B. ALL LIGHT FIXTURES, WIRING DEVICES, ETC. SHOWN ON THIS PLAN WITH A ALL LIGHT FIXTURES, WIRING DEVICES, ETC. SHOWN ON THIS PLAN WITH A SUBSCRIPT "E" IN DASHED LINES ARE EXISTING TO REMAIN AND SHOWN FOR REFERENCE ONLY. C. ALL MATERIALS INSTALLED ABOVE CEILING MUST BE PLENUM RATED. ALL MATERIALS INSTALLED ABOVE CEILING MUST BE PLENUM RATED. . D. ALL BACKBOXES LOCATED IN RATED WALLS SHALL BE ENCASED IN FIRE PUTTY ALL BACKBOXES LOCATED IN RATED WALLS SHALL BE ENCASED IN FIRE PUTTY SEALANT. ALL CONDUITS THAT PASS THRU RATED WALLS MUST BE FIRE SEALED ON BOTH SIDES OF THE WALL. COORDINATE WITH THE ARCHITECT'S DRAWINGS FOR LOCATIONS OF THE RATED WALLS. E. RETAIN THE SERVICES OF THE EXISTING FIRE ALARM MANUFACTERER FOR SYSTEM RETAIN THE SERVICES OF THE EXISTING FIRE ALARM MANUFACTERER FOR SYSTEM MODIFICATIONS, AND NEW DEVICES ADDED TO THE EXISTING SYSTEM. THE BUILDING SHALL REMAIN OCCUPIED THROUGHOUT CONSTRUCTION AND THE FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL THROUGHOUT CONSTRUCTION. AT NO TIME SHALL THE FIRE ALARM SYSTEM GO INTO ALARM DUE TO CONSTRUCTION MODIFICATIONS.

AutoCAD SHX Text

1. CIRCUIT FIXTURES THROUGH SALVAGED LIGHTING CIRCUIT. EXTEND WIRING AS CIRCUIT FIXTURES THROUGH SALVAGED LIGHTING CIRCUIT. EXTEND WIRING AS NECESSARY, MINIMUM #12 AWG AND #12 AWG GROUND IN 3/4" MC CABLE. RETAIN EXISTING LIGHTING CONTROL UNLESS SHOWN OTHERWISE. 2. INSTALL NEW NEMA 3R RATED DISCONNECT TO COMPLY WITH THE WORKSPACE INSTALL NEW NEMA 3R RATED DISCONNECT TO COMPLY WITH THE WORKSPACE REQUIREMENTS OF NEC 110. EXTEND EXISTING CONDUIT AND WIRING TO NEW DISCONNECT AS NECESSARY. MINIMUM #12 AWG AND #12 AWG GROUND IN 3/4" EMT. 3. CIRCUIT NEW HVAC EQUIPMENT FROM SALVAGED WIRING. EXTEND WIRING AS CIRCUIT NEW HVAC EQUIPMENT FROM SALVAGED WIRING. EXTEND WIRING AS NECESSARY, MINIMUM #12 AWG AND #12 AWG GROUND IN 3/4" CONDUIT. 4. PROVIDE 120V POWER FOR HVAC CONTACTOR. CONTACTOR SHALL BE WIRED TO PROVIDE 120V POWER FOR HVAC CONTACTOR. CONTACTOR SHALL BE WIRED TO TURN OFF ALL HVAC EQUIPMENT IN BUILDING. SEE DETAIL ON SHEET E201 FOR MORE INFORMATION. 5. HVAC SHUTOFF PUSHBUTTON. COORDINATE LOCATION WITH ARCHITECT PRIOR TO HVAC SHUTOFF PUSHBUTTON. COORDINATE LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text S

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text B-13,15

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B-17,19

AutoCAD SHX Text B-21,23

AutoCAD SHX Text B-25,27

AutoCAD SHX Text B-29,31

AutoCAD SHX Text

AutoCAD SHX Text S1

AutoCAD SHX Text S1

AutoCAD SHX Text S1

AutoCAD SHX Text S1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text

OS

AutoCAD SHX Text

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text

OS

AutoCAD SHX Text

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text

OS

AutoCAD SHX Text

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

OS

AutoCAD SHX Text

OS

AutoCAD SHX Text L

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

EX. PANEL B

AutoCAD SHX Text E

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text R1

AutoCAD SHX Text S

AutoCAD SHX Text V

AutoCAD SHX Text

AutoCAD SHX Text

OS

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text

%%UCU-1

AutoCAD SHX Text

%%UCU-2

AutoCAD SHX Text

%%UF-1

AutoCAD SHX Text

%%UF-1

AutoCAD SHX Text

%%UAH-1

AutoCAD SHX Text

%%UAH-2

AutoCAD SHX Text

%%UAH-3

AutoCAD SHX Text

%%UHP-2

AutoCAD SHX Text

%%UHP-3

AutoCAD SHX Text

%%UHP-2

AutoCAD SHX Text 30/2,3R

AutoCAD SHX Text

AutoCAD SHX Text 30/2,3R

AutoCAD SHX Text 30/2,3R

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 30/2,3R

AutoCAD SHX Text 30/2,3R

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text B-45

AutoCAD SHX Text

O

J D

AT

E

D R

AW

N

N ew

R iv er E ng in ee rs

, I nc

A

R C

H I

T E

C T

U

V I S

I O

N

R ic hl an d

Av en ue

At he ns , O hi o

Ph on e:

(7

) 5

-9

E-m ai l:

m no el nr en gi nc

.c om

W

ES

T

VI

R G

IN

IA

A R

M Y

N

AT

IO

N

AL

G

U

AR

D

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

FO

R

KI

N

G W

O O

D , W

V

Au gu st

, 2

S H E E T

Su ite

W eb

: w w w .n ew riv er en gi ne er s.

co m

C

AM

P D

AW

SO

N B

U

IL

D

IN

G

A

B

C

D

E

F

G

H

J

K

L

A

B

C

D

F

G

H

J

K

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 E201

EL

EC

TR

IC

AL

D

ET

AI

LS

N H N

AutoCAD SHX Text Dublin, Ohio 43016

AutoCAD SHX Text 6130 Wilcox Road

AutoCAD SHX Text

PRATER

AutoCAD SHX Text Engineering Associates, Inc.

AutoCAD SHX Text

(614) 766 4896

AutoCAD SHX Text praterengineering.com

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

JOB NUM.

AutoCAD SHX Text 26003

AutoCAD SHX Text P

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text H

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text

DOUGLAS L.

AutoCAD SHX Text

POWELL

AutoCAD SHX Text E-57325

AutoCAD SHX Text 08/05/26

AutoCAD SHX Text

E201-26003.DWG

AutoCAD SHX Text

N. RUSSELL

AutoCAD SHX Text

N. RUSSELL

AutoCAD SHX Text

T. LEYKAUF

AutoCAD SHX Text

%%UMETAL PIPE THROUGH CONCRETE FLOOR/WALL OR BLOCK WALL

AutoCAD SHX Text

UL/CUL SYSTEM NO. CAJ1154

AutoCAD SHX Text

F RATING = 3-HR

AutoCAD SHX Text

T RATING = 1/4-HR

AutoCAD SHX Text

L RATING AT AMBIENT = LESS THAN 1 CFM/SQ. FT.

AutoCAD SHX Text

L RATING AT 400%%DF = 4 CFM/SQ. FT.

AutoCAD SHX Text

%%UTOP VIEW

AutoCAD SHX Text

%%USECTION A-A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. CONCRETE FLOOR OR WALL ASSEMBLY (3-HR. FIRE-RATING):

AutoCAD SHX Text

A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOOR OR WALL (MINIMUM 4-1/2" THICK).

AutoCAD SHX Text

B. ANY UL/ULC CLASSIFIED CONCRETE BLOCK WALL.

AutoCAD SHX Text

2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING:

AutoCAD SHX Text

A. MAXIMUM 10" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER).

AutoCAD SHX Text

B. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE.

AutoCAD SHX Text

C. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT.

AutoCAD SHX Text

D. MAXIMUM 4" NOMINAL DIAMETER EMT.

AutoCAD SHX Text

3. BACKER ROD, HILTI CF 128 FILLER FOAM, OR MINERAL WOOL TO BE USED AS BACKER.

AutoCAD SHX Text

4. MINIMUM 1/2" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT.

AutoCAD SHX Text

5. MINIMUM 1/2" BEAD HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT.

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

MAXIMUM DIAMETER OF OPENING = 14".

AutoCAD SHX Text

ANNULAR SPACE = MINIMUM 0", MAXIMUM 3-1/4".

AutoCAD SHX Text MINIMUM 1/2" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT IS REQUIRED ON BOTH SIDES

AutoCAD SHX Text

OF A WALL ASSEMBLY.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

L RATING AT AMBIENT = LESS THAN 1CFM/SQ. FT.

AutoCAD SHX Text

T RATING = 0-HR

AutoCAD SHX Text

F RATING = 1-HR. OR 2-HR.

AutoCAD SHX Text

UL/CUL SYSTEM NO. WL1085

AutoCAD SHX Text

L RATING AT 400%%DF = 4 CFM/SQ. FT..

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

%%UFRONT VIEW

AutoCAD SHX Text

1. GYPSUM WALL ASSEMBLY (UL/ULC CLASSIFIED U300 OR U400 SERIES) (1-HR OR 2-HR FIRE-

AutoCAD SHX Text

2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING:

AutoCAD SHX Text

A. MAXIMUM 12" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER).

AutoCAD SHX Text

B. MAXIMUM 12" NOMINAL DIAMETER CAST IRON PIPE.

AutoCAD SHX Text

C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE.

AutoCAD SHX Text

D. MAXIMUM 6" NOMINAL DIAMETER EMT.

AutoCAD SHX Text

NOTES:

Au…

This is the start of the file's text. The full file is on GovTribe.