This document provides details for a federal contract opportunity to repair and replace the roof of the Lindenwald Mansion. The solicitation number is 140P2122R0042 issued by the Department of the Interior National Park Service. Under this opportunity, the contractor will be required to repair and replace the existing roof of the Lindenwald Mansion building. No other details are provided in this document regarding response dates, pricing terms, or other requirements. An attachment is referenced but its content is not described.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
KEYED NOTES:
AutoCAD SHX Text
1. CLEAN AREA DAILY CLEAN AREA DAILY 2. PROVIDE DROP CLOTHES IN ATTIC TO CATCH FALLING PROVIDE DROP CLOTHES IN ATTIC TO CATCH FALLING DEBRIS. 3. CLEAN ROOF AND GROUND SITE OF ALL NAILS AND CLEAN ROOF AND GROUND SITE OF ALL NAILS AND DEBRIS. 4. OSHA SAFETY MEASURES SHALL BE IN PLACE EVERY OSHA SAFETY MEASURES SHALL BE IN PLACE EVERY DAY. 5. ALL PERSONAL ON ROOF SHALL WEAR PROPER FITTING ALL PERSONAL ON ROOF SHALL WEAR PROPER FITTING FALL PROTECTION AT ALL TIMES ON THE ROOF. 6. BARRICADES SHALL BE USED TO DIRECT FLOW OF BARRICADES SHALL BE USED TO DIRECT FLOW OF TRAFFIC AWAY FROM WORK AREAS.
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AD2
AutoCAD SHX Text
NORTH ELEVATION
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AD2
AutoCAD SHX Text
WEST ELEVATION
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AD2
AutoCAD SHX Text
EAST ELEVATION
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text
AD2
AutoCAD SHX Text
SOUTH ELEVATION
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
DEMO - ELEVATIONS
AutoCAD SHX Text
MAVA 460
AutoCAD SHX Text 178174
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JO
AutoCAD SHX Text
JO
AutoCAD SHX Text
28 JAN 22
AutoCAD SHX Text
MARTIN VAN BUREN
AutoCAD SHX Text
NATIONAL HISTORIC SITE
AutoCAD SHX Text 237315
AutoCAD SHX Text
AD2
A REMOVE EXISTING CEDAR WOOD SHINGLES AND REMOVE EXISTING CEDAR WOOD SHINGLES AND UNDERLAYMENT DOWN TO SKIP SHEATHING. REPLACE ANY DETERIORATED SKIP SHEATHING AND WOOD SPACERS (UP TO 800 L.F.) FIELD VERIFY. REMOVE EXCESS NAILS. PATCH IF NECESSARY. B CAREFULLY REMOVE EXISTING LIGHTNING PROTECTION CAREFULLY REMOVE EXISTING LIGHTNING PROTECTION SYSTEM RODS. RE-INSTALL AND TEST LIGHTNING PROTECTION WHEN ROOF IS COMPLETE. PROVIDE TEMPORARY LIGHTNING PROTECTION DURING CONSTRUCTION C REMOVE EXISTING FLASHING AROUND ALL CHIMNEYS, REMOVE EXISTING FLASHING AROUND ALL CHIMNEYS, DORMERS AND TOWER. D REMOVE VALLEY FLASHING DOWN TO SKIP SHEATHING. REMOVE VALLEY FLASHING DOWN TO SKIP SHEATHING. E CAREFULLY RE-MOVE EXISTING HEAT TAPE INSTALLED ON CAREFULLY RE-MOVE EXISTING HEAT TAPE INSTALLED ON ROOF TO INSTALL NEW SHINGLES. F AFTER INSTALLATION OF SHINGLES, CONTRACTOR SHALL AFTER INSTALLATION OF SHINGLES, CONTRACTOR SHALL REPLACE HEAT TAPE SYSTEM BACK ON SHINGLES IN PLACE AND TEST. (OPTION 1) G CAREFULLY REMOVE ALL DETERIORATED SIDING OF 4 CAREFULLY REMOVE ALL DETERIORATED SIDING OF 4 SMALL DORMERS.
N
AutoCAD SHX Text
AutoCAD SHX Text A1.1
AutoCAD SHX Text
MAIN ROOF PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
ROOF REPLACEMENT TO INCLUDE 4 DORMERS.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
MAIN ROOF PLAN
AutoCAD SHX Text
MAVA 460
AutoCAD SHX Text 178174
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JO
AutoCAD SHX Text
JO
AutoCAD SHX Text
28 JAN 22
AutoCAD SHX Text
MARTIN VAN BUREN
AutoCAD SHX Text
NATIONAL HISTORIC SITE
AutoCAD SHX Text 237315
AutoCAD SHX Text A1.1
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
AutoCAD SHX Text A1.2
AutoCAD SHX Text
1. INSTALL NEW 30# FELT ALONG THE EAVES, VALLEYS, INSTALL NEW 30# FELT ALONG THE EAVES, VALLEYS, RAKES, RIDGE AND TRANSITION OF ALL ROOFS. AREAS TO BE COVERED WITH FELT SHOULD NOT BE VISIBLE FROM BELOW. 2. INSTALL FELT STRIPS, DISTANCE FROM BUTT OF THE INSTALL FELT STRIPS, DISTANCE FROM BUTT OF THE SHINGLE TO BOTTOM OF INTERLAYMENT EQUAL TO TWICE THE WEATHER EXPOSURE 3. INSTALL NEW SHINGLES (SEE SHINGLE TYPE BELOW) INSTALL NEW SHINGLES (SEE SHINGLE TYPE BELOW) WITH STAINLESS STEEL NAILS. NAILS TO BE FLUSH WITH SURFACE. SHINGLES SHALL BE PROVIDED BY THE NATIONAL PARK SERVICE. ESTIMATE FOR AN ADDITIONAL 1300 SQ FT OF CEDAR SHINGLES TO BE PROVIDED BY CONTRACTOR. 4. INSTALL NEW FLASHING AROUND VALLEYS AND ROOF INSTALL NEW FLASHING AROUND VALLEYS AND ROOF PENETRATIONS, DORMERS. 5. ALL ROOF PROTECTION ANCHORS AND/OR SYSTEMS ALL ROOF PROTECTION ANCHORS AND/OR SYSTEMS SHALL BE PROVIDED BY CONTRACTOR. EXISTING ANCHOR POINTS SHALL BE ASSUMED UNSAFE AND SHALL NOT BE USED. 6. INSTALL NEW DORMER SIDING ON BOTH SIDES ON ALL 4 INSTALL NEW DORMER SIDING ON BOTH SIDES ON ALL 4 SMALL DORMERS AS INDICATED IN DRAWING. ESTIMATE REPLACEMENT OF 1X12 BOARDS TO BE 300 L.F. CONTRACTOR SHALL FIELD VERIFY. CONTRACTOR SHALL REUSE ANY BOARDS THAT ARE IN SOUND CONDITION. NEW SIDING BOARDS SHALL MATCH EXISTING. 7. REPAIR ANY DETERIORATED BOX SILLS AT PERIMETER OF REPAIR ANY DETERIORATED BOX SILLS AT PERIMETER OF ROOF EST. 100 LINEAR BOARD. 8. (OPTION 1) REPLACE EXISTING HEAT TRACE TAPE WITH (OPTION 1) REPLACE EXISTING HEAT TRACE TAPE WITH NEW HEAT TRACE TAPE. NEW HEAT TRACE SHALL BE CONNECTED TO EXISTING CONTROL PANEL AND INCLUDE CONTROLS THAT MANUFACTURER RECOMMENDS. 9. (OPTION 2) APPLY AN ELASTOMERIC ACRYLIC COATING (OPTION 2) APPLY AN ELASTOMERIC ACRYLIC COATING ON ALL STANDING SEAM METAL ROOF INCLUDING TOWER. ROOF SHALL BE PREPARED PRIOR TO APPLICATION. APPLICATION SHOULD BE APPLIED PER MANUFACTURERS RECOMMENDATION. ESTIMATE FOR AN AREA OF 3200 SQ FT OF COATING.
AutoCAD SHX Text
ROOFING NOTES:
AutoCAD SHX Text
APPLY ELASTOMERIC ACRYLIC COATING ON ALL STANDING SEAM METAL ROOF (OPTION 2)
AutoCAD SHX Text CERTIGRADE ALASKA YELLOW CEDAR, BLUE LABEL NUMBER 1 GRADE, CERTI-LAST PRESSURE IMPREGNATED WOOD PRESERVATIVE SHINGLES. 100% CLEAR HEARTWOODM 100% EDGE GRAIN AND NO DEFECTS. 18" LING (PERFECTION), 5/2 14" THICKNESS.
SHINGLE TYPE
WOOD SHINGLE ROOFING; TRIM TO PROVIDE
UNIFORM LINES WITH VALLEY FLASHING -----.
NYLON DRAINAGE MATRIX -----�
VALLEY CLIPS @12" O.C. 2 ---�
FASTENERS PER CLIP
MODIFIED BITUMEN UNDERLAYMENT---.
SHEET METAL VALLEY FLASHING
1" RIDGE ----�
1 DORMER VALLEY - ROOF AREA
A 1 .2 SCALE: NTS
ROOFING NOTES:
1. ROOF HAS AN ESTIMATED AREA OF 3800 SQ FT. INCLUDING DORMERS.
2. CEDAR SHINGLES WILL BE PROVIDED BY NATIONAL PARK SERVICE AND
DELIVERED TO SITE PRIOR TO COMMENCEMENT OF CONSTRUCTION.
NATIONAL PARK SERVICE SHALL PROVIDE 40 SQUARE PALLETS OF ROOF
SHINGLES.
3. CONTRACTOR SHALL INSPECT NEW SHINGLES PROVIDED BY THE
NATIONAL PARK SERVICE. CONTRACTOR WILL PROVIDE ANY ADDITIONAL
PURCHASE OF CEDAR SHINGLES TO MATCH EXISTING PURCHASED ONES.
ESTIMATE OF ROOF SHINGLES TO PURCHASE IS 33% (1300 SQUARE
FT) OF CEDAR SHINGLES.
4. CONTRACTOR SHALL BE PREPARE TO REPLACE AN ESTIMATE OF 25% OF
ROOFING BOARDS (800 L.F.) CONTRACTOR SHALL MATCH NEW ROOFING
BOARDS TO EXISTING BOARDS. ROOFING BOARDS ARE 1 X RANGING FROM
8" TO 1 '3".
5. ALL OTHER MATERIALS TO COMPLETE ROOF REPLACEMENT SHALL BE
PURCHASED BY CONTRACTOR.
PREPARATION NOTES:
1. CONTRACTOR WILL ENSURE ALL AREAS WITHIN CONSTRUCTION SITE
SHALL BE PROTECTED, SUCH AS WINDOWS.
2. CONTRACTOR SHALL PROVIDE GROUND CONSTRUCTION MATS ON ALL
GRASS AREAS FOR PROTECTION IF LIFTS WILL BE USED TO ACCESS
ROOF.
3. ASSUME ADDITIONAL 10% OF SQ. FT. FOR ADDITIONAL ELEMENTS TO BE
PAINTED THAT ARE DISCOVERED DURING CONSTRUCTION.
,------CEDAR RIDGE CAP BOARDS
�-BREATHABLE UNDERLAYMENT
BELOW RIDGE BOARDS
�-WOOD SHINGLE ROOFING
MODIFIED BITUMEN UNDERLAYMENT;
18" EACH SIDE OF RIDGE
EXISTING SKIP SHEATHING
EXISTING TRUSS
DORMER RIDGE - ROOF AREA
SCALE: NTS
APPLY CEDAR SHINGLES
OVER ROOF BOARDS. AT
VALLEYS APPLY CEDAR
OVER APPLIED FELT AND
METAL PROTECTION
VALLEY METAL DETAIL
SCALE: NTS
�-----------./41-''
·· ....... �:�,;rfr . EAVE PROTECTION (EXTEND
· "/ / TO RAKE EDGE
/// SOLID BOARD SHEATHING AT EAVE
(IF NO KNOWN SOLID SHEATHING AT
EAVES, CONTRACTOR SHALL INSTALL
BOARDS TO FILL GAPS
OPEN VALLEY WIDTH 6" - 8"
ROOFING 30# FELT
VALLEY ALUMINUM
FLASHING OVERLAPPED 6"
AT JOINTS
.------ CEDAR RIDGE CAP BOARDS
�BREATHABLE UNDERLAYMENT
BELOW RIDGE BOARDS
� WOOD SHINGLE ROOFING
CEDAR WOOD SHINGLE -�
FELT STRIPS
MODIFIED BITUMEN UNDERLAYMENT; MINERAL-SURFACED CAP
18" EACH SIDE OF RIDGE SHEET UNDERLAYMENT
EXISTING WOOD ROOF DECK
ROOFING BOARDS ----,,(f',.
ROOF FRAMING �er//4
- ROOF AREA - ROOF AREA
SCALE: NTS
� - CEDAR ROOF SHINGLES
FELT STRIPS. THE BOTTOM EDGE OF THE FELT SHOULD BE
POSITIONED ABOVE THE BUTT OF THE SHINGLE AT A
DISTANCE TO TWICE THE WEATHER EXPOSURE. CONTRACTOR
SHALL NOT INTERLAY SHINGLES WITH FELT
SPACED SHEATHING
(EXISTING, LEAVE IN PLACE) 3" MINIMUM
CAULKING�<"-'
24 GAUGE ALUMINUM-_/
FLASHING COATED
SOLID BOARD SHEATHING AT EAVE
SCALE: NTS
CEDAR ROOF
SHINGLES
,---- STEP FLASHING
(IF NO KNOWN SOLID SHEATHING AT
EAVES, CONTRACTOR SHALL INSTALL
BOARDS TO FILL GAPS
30# FELT EAVE PROTECTION. FELT SHALL
BE USED ON ALL EAVES WITH 36" FELT
ALUMINUM FLASHING (ALUMINUM
SHALL BE PAINTED TO MATCH
EXISTING FLASHING, PAINTING
SHALL BE APPLIED ACCORDING T
MANUFACTURER SPECIFICATIONS
FOR PAINTING FLASHING)
SPACED SHEATHING TYP. CHIMNEY PROJECTION FLASHING TYP
SCALE: NTS
DESIGNED: SUB SHEIT NO.
JO
@t'l•i•u
JO
TECH. REVIEW:
DATE:
28 JAN 22
SCALE: NTS
TITLE OF SHEIT
ROOF DETAILS
MARTIN VAN BUREN
NATIONAL HISTORIC SITE
DRAWING NO.
MAVA 460
178174
PMIS/PKG NO.
237315
SHEIT
| Cover Sheet |
| AD1 |
| AD2 |
| Sheets and Views |
| Demo Sheet AD2 |
| PLOT |
| A1.1 |
| Sheets and Views |
| A1 |
| PLOT |
A1.2
File details come from the government source that posted it. Updated .