Attch 2 - Drawings.pdf

PDF 14 MB Posted

Attached to
Addition to 24 SOW HQ Bldg 90310
Solicitation number
FA441720R0008
Issued by

About this file

This solicitation is for an addition to the 24th Special Operations Wing Headquarters Building 90310. The project includes minor demolition and new construction for a one-story addition with masonry walls, metal roof trusses, EIFS and split-face CMU finishes, and interior finishes to match the existing building. Site work relocates a picnic shelter and reroutes utilities. Expansion of mechanical, fire sprinkler, electrical, and communication systems is also required. The estimated value is between $1-2 million. The acquisition will be set aside for Women Owned Small Businesses. The contract will be awarded using FAR Part 15 procedures and is a single-award, firm-fixed price contract for a 300-day performance period. Bid and payment/performance bonds are required. The work supports the 1st Special Operations Civil Engineer Squadron. Offerors must register in SAM to be eligible for award. The solicitation is available at beta.SAM.gov and electronic submission of proposals is anticipated.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P O

O L

P O

O L

P O

O L

P O

O L

P O

O L

M A R Y E S T H E R , F L O R I D A

HIGHWAY 98

HIGHWAY 98

NORTH

BASE MAP

NORTH

MARTIN LUTHER KING JR. BLVD

INTERSECTION ENTRANCE

COMMERCIAL VEHICLE INSPECTION

ENTRANCE PASS & ID OFFICE

HURLBURT EAST GATE, NO

COMMERCIAL ENTRANCE

FIRE DEPARTMENT BLDG 90734

CONTRACTOR HAUL ROUTE

O 'N

E

IL

A

VE

N U

E

INDEPENDENCE ROAD

EXISTING BUILDING

90310

McMILLAN STREET

LE

T

O U

R N

E A

U C

IR

C

LE

LE

T

O U

R N

E A

U C

IR

C

LE

C O

D Y

A V

E N

U E

MITCHELL ROAD

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

A

TI

O

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

S

P

EC

IA

L

O

PE

R A

TI

O

N S

C

IV

IL

E

N G

IN

E

ER

S

Q U

A D

R O

N

H U

R

LB

U R

T

FI

EL

D

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

G-001

03/30/2020

T

IT

LE

S

H E

E T

GJD

LS

CP1033113

B U

IL

D

IN

G

A D

D

IT

IO

N

24 SOW HW, BLDG 90310 ADDITION

HURLBURT FIELD, FLORIDA

CP1033113

NORTH

PROJECT SITE

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

RLT

03/30/20

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

A

TI

O

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

S

P

EC

IA

L

O

PE

R A

TI

O

N S

C

IV

IL

E

N G

IN

E

ER

S

Q U

A D

R O

N

H U

R

LB

U R

T

FI

EL

D

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

G-002

03/30/2020

IN

D

E X

O F

D R

A W

IN

G

S

GJD

LS

CP1033113

B U

IL

D

IN

G

A D

D

IT

IO

N

INDEX OF DRAWINGS

SHEET

NUMBER SHEET NAME

ELECTRICAL

E-001 RISER, LEGEND, GENERAL NOTES

E-002 LIGHTING FIXTURE SCHEDULE, DETAILS

E-003 PANELBOARD SCHEDULES, LIGHTING DETAILS

E-004 ELECTRICAL SITE PLAN

E-005 METER DETAILS

E-006 METER DETAILS

E-101 ELECTRICAL DEMOLITION PLAN

E-102 LIGHTING PLAN

E-103 POWER PLAN

FIRE ALARM

FA101 FIRE ALARM / MASS NOTIFICATION SYSTEM PLAN

TELECOMMUNICATIONS

T-001 COMMUNICATIONS PLAN

T-002 VOICE SYSTEM SINGLE LINE DIAGRAM

T-003 DATA SYSTEM SINGLE LINE DIAGRAM

T-101 COMMUNICATIONS PLAN

INDEX OF DRAWINGS

SHEET

NUMBER SHEET NAME

GENERAL

G-001 TITLE SHEET

G-002 INDEX OF DRAWINGS

G-101 LIFE SAFETY PLAN

G-110 AIR BARRIER PLAN DIAGRAM

G-111 AIR BARRIER SECTION DIAGRAMS

CIVIL

VF101 EXISTING CONDITIONS

CD101 DEMOLITION PLAN

CS101 SITE PLAN

CS201 CONCRETE JOINT PLAN

CU101 UTILITY PLAN

STRUCTURAL

S-001 GENERAL NOTES

S-002 GENERAL NOTES CONTINUED

S-101 SLAB-ON-GRADE PLAN

S-102 ROOF FRAMING PLAN

S-201 ELEVATIONS

S-301 SECTIONS

S-302 SECTIONS

S-501 DETAILS

S-502 DETAILS

DEMOLITION

D-101 DEMOLITION

ARCHITECTURAL

A-001 WALL TYPES, SYMBOLS & ABBREVIATIONS

A-101 ARCHITECTURAL SITE PLAN

A-110 OVERALL PLAN

A-111 FLOOR PLAN - NOTES

A-112 FLOOR PLAN - DIMENSIONS

A-113 FURNITURE PLAN

A-140 ROOF PLAN

A-150 REFLECTED CEILING PLAN

A-201 EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS & SECTION DETAILS

A-310 WALL SECTIONS

A-501 PLAN DETAILS

A-601 DOOR SCHEDULE AND WINDOW ELEVATIONS

A-602 DOOR & WINDOW DETAILS

A-603 DETAILS

INTERIOR

I-101 FINISH PLAN

I-601 FINISH SCHEDULE AND DETAILS

FIRE PROTECTION

F-001 GENERAL FIRE PROTECTION INFORMATION

FX101 FLOOR PLAN - NEW WORK - FIRE PROTECTION

F-501 FIRE PROTECTION DETAILS

F-502 FIRE PROTECTION DETAILS

MECHANICAL

M-001 GENERAL MECHANICAL INFORMATION

MD101 FLOOR PLAN - PIPING - DEMOLITION BID OPTION #1

MH101 FLOOR PLAN - DUCTWORK - NEW WORK

MP101 FLOOR PLAN - PIPING - NEW WORK

MP102 OVERALL FLOOR PLAN - PIPING

MP103 FLOOR PLAN - PIPING - NEW WORK BID OPTION #1

M-501 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

MI701 MECHANICAL CONTROLS

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

C O

M M

O N

P A

T H

TOTAL TRAVEL DISTANCE: 128'

T O

T A

L T

R A

V E

L D

IS

T

A N

C E

: 1

COMMON PATH OF TRAVEL: 40'

COMMON PATH OF TRAVEL: 47'

TOTAL TRAVEL DISTANCE: 112'

T O

T A

L T

R A

V E

L D

IS

T

A N

C E

: 9 6'

C O

M M

O N

P A

T H

O F

T R

A V

E L:

8'

T O

T A

L T

R A

V E

L D

IS

T

A N

C E

: 1

EXISTING

B-BUSINESS OCCUPANCY

EXISTING A3-ASSEMBLY

OCCUPANCY

EXISTING OFFICE

NOT IN SCOPE

(SEPARATE OCCUPANCY)

T O

T A

L T

R A

V E

L D

IS

T

A N

C E

: 1

TOTAL

TRAVEL

DISTANCE: 99'

D E

A D

E N

D

106 108 109

111112113114

116115

120119

FEC

FEC

FEC

LIFE SAFETY DATA - INTERNATIONAL

BUILDING CODE 2018 EDITION

NATIONAL FIRE PROTECTION ASSOCIATION

(NFPA) LIFE SAFETY CODE 101, 2018 EDITION

OCCUPANCY CLASSIFICATION: NFPA 101, 2018 - BUSINESS/CONCENTRATED BUSINESS

CONSTRUCTION TYPE: NFPA 101, 2018 - TYPE V B SPRINKLERED

FIRE RESISTANCE: NFPA 101, 2018 - NONE REQUIRED FOR FRAME, BEARING WALLS OR

PARTITIONS

PLUMBING FIXTURE COUNT:

PLUMBING FIXTURE COUNT: (IBC - PLUMBING CHAPTER 4)

38 TOTAL OCCUPANTS (ADDITION) SHALL BE SERVED BY FIXTURES IN EXISTING BUILDING**

75/25 PROPORTION MALE TO FEMALE (AS PROVIDED BY OWNER) = 29 MALE, 9 FEMALE

**EXISTING BUILDING BUILDING PLUMBING FIXTURE ANALYSIS:

LOAD FOR B (BUSINESS) OCCUPANCY = 103 OCCUPANTS

LOAD FOR A3 (ASSEMBLY) OCCUPANCY = 100 OCCUPANTS

TOTAL OCCUPANT LOAD = 203 OCCUPANTS

80/20 PROPORTION MALE TO FEMALE (AS PROVIDED BY OWNER) = 163 MALE, 41 FEMALE

TOTAL LOAD = 163+29 =192 MALE AND 41+9 =50 FEMALE

TOTAL OCCUPANT LOAD = 240

WATER CLOSETS (W/C):

1 PER 25 FOR 1st 50, THEN 1 PER 50=

MALE - 5 W/C REQ'D (3 W/C & 4 URINALS PROVIDED)

FEMALE - 2 W/C REQ'D (2 PROVIDED)

LAVATORIES (LAV):

1 PER 40 FOR 1st 80, THEN 1 PER 80=

MALE - 4 LAV REQ'D (4 PROVIDED)

FEMALE - 2 LAV REQ'D (2 PROVIDED)

DRINKING FOUNTAINS (DF):

1 PER 100=

MALE & FEMALE = 3 DF REQ'D (3 PROVIDED)

MEANS OF EGRESS:

OCCUPANT LOAD:

TOTAL: 42 OCCUPANTS

BUSINESS USE (1:100) = 1,255 SF / 100 GSF = 13 OCCUPANTS

BUSINESS USE CONCENTRATED (1:50) = 1,271 SF / 50 GSF = 26 OCCUPANTS

STORAGE/MECHANICAL (1:300) = 715 SF / 300 GSF = 3 OCCUPANTS

EGRESS WIDTH: 0.2 IN./PERSON (NFPA 101: TABLE 7.3.3.1) 8.4" REQUIRED FOR ADDITION* PROVIDED FROM EACH SPACE WITH 36" WIDE, 34" CLEAR DOORS = 3 x 34" = 102" PROVIDED

*EXISTING BUILDING EGRESS WIDTH ANALYSIS:

ORIGINAL EGRESS WIDTH REQUIRED: 115 OCCUPANTS + 38 = 153

153 x 0.20= 30.6" MIN. REQUIRED

PROVIDED 3-36" WITH 34" MIN. CLEAR WIDTH = 3X34" = 102" PROVIDED

NUMBER OF EXITS: (NFPA 101: 7.4.1.2 & 39.2.4.3) OCCUPANT LOAD > 49 AND < 500 = 2 EXITS

REQUIRED

3 PROVIDED

TRAVEL DISTANCE:

COMMON PATH OF TRAVEL: 100' MAX. (NFPA 101: 39.2.5.3.1)

53' - COMPLIES

MAXIMUM TRAVEL DISTANCE TO EXIT: 300' MAX. (NFPA 101: 39.2.6.3)

142' - COMPLIES

DEAD END: 50' MAX. (NFPA 101: 39.2.5.2)

31' - COMPLIES

LIFE SAFETY LEGEND

PORTABLE FIRE EXTINGUISHER.

REGULAR DRY CHEMICAL (SODIUM

BICARBONATE BASED)

FIRE EXTINGUISHER UL RATED 10-B.C

10LB NORMAL CAPACITY.

ENAMELED-STEEL CONTAINER.

FE 1 =

EXIT PATH WITH TOTAL

TRAVEL DISTANCE AND

DIRECTION OF TRAVEL.

FIRE EXTINGUISHER CABINET WITH

FE 1 PORTABLE

FIRE EXTINGUISHER.

FEC =

TRAVEL

DISTANCE: XX'

EXIT SIGN (SHADED REGION

INDICATES LIGHTED SIDE)

ROOM NAME / NUMBER

DESIGNATION101

ROOM NAME

COMMON PATH OF TRAVEL

COMMON PATH: XX'

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

A

TI

O

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

S

P

EC

IA

L

O

PE

R A

TI

O

N S

C

IV

IL

E

N G

IN

E

ER

S

Q U

A D

R O

N

H U

R

LB

U R

T

FI

EL

D

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

G-101

03/30/2020

LI

F

E S

A F

E T

Y P

LA

N

GJD

LS

CP1033113

B U

IL

D

IN

G

A D

D

IT

IO

N

3/32" = 1'-0"G-101

2 LIFE SAFETY PLAN - OVERALL WITH EXISTING

SCALE: 3/32" = 1'-0"

0 5'-4" 10'-8" 21'-4"

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

111112114

106 108

109115 116

100 103

G-111

G-111

DDDDD

ZONE 1

DD

DD

D

D

D

D

D

A

A

SEAL OFF EXISTING WALL

FROM TOP OF FLOOR TO

UNDERSIDE OF DECK

DURING TESTING

4' -0

119 120

KEYNOTES

PAINTED GYPSUM WALLBOARD

PERFORMS AS AIR BARRIER.

CONCRETE SLAB PERFORMS AS AIR

BARRIER.

ROOFING UNDERLAYMENT PERFORMS

AS AIR BARRIER

FLUID APPLIED AIR/MOISTURE BARRIER

PERFORMS AS AIR BARRIER.

A

B

C

D

GENERAL NOTES

1. DRAWINGS ON THIS SHEET ARE

PROVIDED TO SHOW DIAGRAMMATIC

LOCATION OF AIR BARRIER.

2. SEE WALL SECTIONS AND DETAILS FOR

ADDITIONAL AIR BARRIER INFORMATION.

GRAPHIC LEGEND

AIR BARRIER LOCATION

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

A

TI

O

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

S

P

EC

IA

L

O

PE

R A

TI

O

N S

C

IV

IL

E

N G

IN

E

ER

S

Q U

A D

R O

N

H U

R

LB

U R

T

FI

EL

D

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

G-110

03/30/2020

A

IR

B A

R R

IE

R

P

LA

N D

IA

G

R A

M

GJD

LS

CP1033113

B U

IL

D

IN

G

A D

D

IT

IO

N

3/16" = 1'-0"G-110

1 AIR BARRIER PLAN DIAGRAM

ROOM NAMES

NUMBER NAME

100 LOBBY

101 EXIST. MECH.

102 CORR.

103 SIPR

104 24 SOW/SG

105 HISTORIAN

106 COPY

107 CORR.

108 MECHANICAL

109 RELIGIOUS SUPPORT

110 CHAPLAIN

111 POTFF PROG. MANAGER

112 FINANCIAL COUNSELOR

113 WW PROGRAM MANAGER

114 WING COMM PSYCH

115 GENERAL STORAGE 1

116 GENERAL STORAGE 2

117 COMBAT CAM STORAGE

118 OPEN OFFICE

119 CCPNC DIRECTOR

120 HP PROGRAM ADVISOR

SCALE: 3/16" = 1'-0"

0 2'-8" 5'-4" 10'-8"

NORTH

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

G-111

D

C

B

ZONE 1

B

C

SEAL OFF EXISTING WALL

FROM TOP OF FLOOR TO

UNDERSIDE OF DECK

DURING TESTING

G-111

D

B

C

B

C

BD

C

ZONE 1

KEYNOTES

PAINTED GYPSUM WALLBOARD

PERFORMS AS AIR BARRIER.

CONCRETE SLAB PERFORMS AS AIR

BARRIER.

ROOFING UNDERLAYMENT PERFORMS

AS AIR BARRIER

FLUID APPLIED AIR/MOISTURE BARRIER

PERFORMS AS AIR BARRIER.

A

B

C

D

GRAPHIC LEGEND

AIR BARRIER LOCATION

GENERAL NOTES

1. DRAWINGS ON THIS SHEET ARE

PROVIDED TO SHOW DIAGRAMMATIC

LOCATION OF AIR BARRIER.

2. SEE WALL SECTIONS AND DETAILS FOR

ADDITIONAL AIR BARRIER INFORMATION.

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

A

TI

O

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

S

P

EC

IA

L

O

PE

R A

TI

O

N S

C

IV

IL

E

N G

IN

E

ER

S

Q U

A D

R O

N

H U

R

LB

U R

T

FI

EL

D

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

G-111

03/30/2020

A

IR

B A

R R

IE

R

S E

C T

IO

N

D

IA

G R

A M

S

GJD

LS

CP1033113

B U

IL

D

IN

G

A D

D

IT

IO

N

3/16" = 1'-0"G-111

1 AIR BARRIER CROSS SECTION

3/16" = 1'-0"G-111

2 AIR BARRIER LONGITUDINAL SECTION

SCALE: 3/16" = 1'-0"

0 2'-8" 5'-4" 10'-8"

AR94997

DERETSI

G

E R

A R C H

IT

E C

T

FOETAT

S

FL O R ID

A

R ICE

ACREBO

R

STORAGE

CONTAINER

6.5'X8.5'X4.5'

SRV

SRV

SRV

S D x S

D x

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CATCH BASIN

TOP= 32.98'

15" RCP S INV= 29.86' CATCH BASIN

TOP= 33.86'

12" RCP N INV= 29.87'

12" RCP S INV= 29.88'

6' CHAIN LINK FENCE

6' CHAIN LINK FENCE

4" METAL BOLLARD

TYPICALELECTRIC BELOW

GROUND VAULT

FIBER OPTIC BELOW

GROUND VAULTELECTRIC BELOW

GROUND VAULT

FIBER OPTIC BELOW

GROUND VAULT

EDGE OF PAVEMENT

CENTERLINE

7" BLOCK WALL

7" BLOCK WALL

CHILLER

AC

D

S

S x

S

S x

S

S x

S

S x

S

Sx

W x

W x

W x

W x

W x W x

W x

W xW x

W x

W x

W x

W x W x

W x

W x

W xW xW x

W x W x

W x

W x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

18" RCP

INV: 27.18'

12" RCP

TOP= 31.22'

INV: 27.0'±

CATCH BASIN

TOP= 30.62'

18" RCP SW INV: 28.46'

NE INV= 28.50'

STORM SEWER MANHOLE

TOP= 32.51'

12" RCP SW INV= 27.4'±

12" RCP INV= 27.3'±

S

S x

S

S x

S

S x

CONTROL POINT #2

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=521735.62'

EASTING=1274196.36'

ELEVATION=32.82'

CONTROL POINT #1

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=522096.68'

EASTING=1274199.63'

ELEVATION=34.01'

ONE STORY

STUCCO AND BLOCK

BUILDING 90310

F.F.E.=34.99'

GYM EQUIPMENT

GYM EQUIPMENT

COVERED PICNIC

AREA

2" METAL

ROOF DRAIN

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

S

D x

S

D x

S

D x

D

S D x

S D x

S D x

S D x

S D x

S D x

S D x

S D x

6" FIRE LINE

4" REMOTE

FDC LNE

S

D x

S

D x

S

D x

ABBREVIATIONS AND SYMBOLS

= BACKFLOW PREVENTER

= LIGHT POLE

= IRRIGATION CONTROL VALVE

= BOLLARD

F.F.E. = FINISHED FLOOR ELEVATION

(F) = VALUE DERIVED FROM FIELD SURVEY

= BENCHMARK

= CABLE TELEVISION PEDESTAL/SERVICE BOX

= POST

SRV = SERVICE BOX

= BURIED STORMWATER SEWER

= BURIED WATER LINE

SD

x

W x

= BRICK

= WALL

= CONCRETE

BM

= ASPHALT PAVEMENT

= 6" PVC ROOF DRAIN

= BURIED SANITARY SEWER (SURVEY)SS

x

= BURIED COMMUNICATIONS LINECOMM

= CHAIN LINK FENCEX

= BURIED ELECTRICAL (GIS DATA)E

x

0 20' 40'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

1 S

PE

CIA

L O

PE

RA

TIO

NS

CI

VIL

EN

GIN

EE

R S

QU

AD

RO

N

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

B U

I L D

I N

G

A

D D

I T

I O

N

146316.14

V:

\2

6\ ac tiv e\

4\ ci vil

\d ra w in g\

-d sg n\ sh ee t_ file s\

VF

1.

dw g

/0

3/

:5

PM B

y:

G er th

, J am es

EXISTING CONDITIONS

1" = 20'

VF101

E X

I S

T I N

G

C

O N

D I T

I O

N S

CEB

BP

3/30/2020

EXISTING LEGEND

jgerth 90310

S D x S

D x

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

CATCH BASIN

TOP= 32.98'

15" RCP S INV= 29.86' CATCH BASIN

TOP= 33.86'

12" RCP N INV= 29.87'

12" RCP S INV= 29.88'

S

S x

S

S x

S

S x

S

S x

S

Sx

W x

W x

W x

W x

W x W x

W x

W xW x

W x

W x

W x

W x W x

W x

W x

W xW xW x

W x W x

W x

W x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

18" RCP

INV: 27.18'

12" RCP

TOP= 31.22'

INV: 27.0'±

CATCH BASIN

TOP= 30.62'

18" RCP SW INV: 28.46'

NE INV= 28.50'

STORM SEWER MANHOLE

TOP= 32.51'

12" RCP SW INV= 27.4'±

12" RCP INV= 27.3'±

S

S x

S

S x

S

S x

CONTROL POINT #2

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=521735.62'

EASTING=1274196.36'

ELEVATION=32.82'

CONTROL POINT #1

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=522096.68'

EASTING=1274199.63'

ELEVATION=34.01'

ONE STORY

STUCCO AND BLOCK

BUILDING 90310

F.F.E.=34.99'

BASEBALL DUGOUT

COVERED PICNIC

AREA

2" METAL

ROOF DRAIN

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

S

D x

S

D x

S

D x

D

S D x

S D x

S D x

S D x

S D x

S D x

S D x

S D x

6" FIRE LINE

4" REMOTE

FDC LNE

S

D x

S

D x

S

D x

ABBREVIATIONS AND SYMBOLS

= BACKFLOW PREVENTER

= LIGHT POLE

= IRRIGATION CONTROL VALVE

= BOLLARD

F.F.E. = FINISHED FLOOR ELEVATION

(F) = VALUE DERIVED FROM FIELD SURVEY

= BENCHMARK

= CABLE TELEVISION PEDESTAL/SERVICE BOX

= POST

= SERVICE BOX

= BURIED STORMWATER SEWER

= BURIED WATER LINE

SD

x

W x

= BRICK

= WALL

= CONCRETE

BM

= ASPHALT PAVEMENT

= 6" PVC ROOF DRAIN

= BURIED SANITARY SEWER (SURVEY)SS

x

= BURIED COMMUNICATIONS LINECOMM

= CHAIN LINK FENCE

= BURIED ELECTRICAL (GIS DATA)E

x

0 20' 40'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

1 S

PE

CIA

L O

PE

RA

TIO

NS

CI

VIL

EN

GIN

EE

R S

QU

AD

RO

N

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

B U

I L D

I N

G

A

D D

I T

I O

N

146316.14

V:

\2

6\ ac tiv e\

4\ ci vil

\d ra w in g\

-d sg n\ sh ee t_ file s\

C D1

.d w g

/0 3/

:5

PM B

y:

G er th , J am es

DEMOLITION PLAN

1" = 20'

CD101

D E

M O

L I T

I O

N

P

L A

N

CEB

BP

3/30/2020

DEMOLITION LEGEND

CONCRETE REMOVAL

UTILITY REMOVAL

STRUCTURE REMOVAL AND RELOCATION

REMOVE 4" FIRE LINE

REMOVE 6" FIRE LINE

PROTECT BURIED COMMUNICATIONS LINES

(TO REMAIN)

REMOVE DROP INLET

REMOVE AND RELOCATE COVERED PICNIC AREA

REMOVE SIDEWALK

AND PAVERS

REMOVE SIDEWALK

EXISTING 4" FIRE LINE

TO REMOTE FDC

EXISTING 6" FIRE LINE

EXISTING LEGEND

REMOVE GYM EQUIPMENT

GENERAL NOTES:

1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND

SPECIFICATIONS AND THE REQUIREMENTS AND STANDARDS OF ALL GOVERNING

AUTHORITIES.

2. THE LOCATION OF UNDERGROUND FACILITIES SHOWN ON THESE PLANS IS BASED

ON INFORMATION PROVIDED BY THE UTILITIES AND SHALL BE CONSIDERED

APPROXIMATE. IT SHALL BE THE CONTRACTOR'S FULL RESPONSIBILITY TO

CONTACT THE VARIOUS UTILITY COMPANIES TO LOCATE THEIR FACILITIES PRIOR

TO STARTING CONSTRUCTION. NO ADDITIONAL COMPENSATION SHALL BE PAID TO

THE CONTRACTOR FOR DAMAGE AND REPAIR TO THESE FACILITIES CAUSED BY HIS

WORK FORCE.

3. ALL EXCESS MATERIAL SHALL BE HAULED AWAY AND DISPOSED OF

APPROPRIATELY AT THE CONTRACTOR'S EXPENSE.

4. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY

THE CONTRACTOR PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY

THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH

CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA

COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR WORK HAVING TO BE

REDONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS

IF SUCH NOTIFICATION HAS BOT BEEN GIVEN.

5. THE CONTRACTOR IS TO COORDINATE WITH THE RESPONSIBLE UTILITY PROVIDER

FOR PROTECTION/HOLDING OF UTILITY POLES, GUY WIRES AND GUY ANCHORS IN

AREAS OF CONSTRUCTION. THE CONTRACTOR SHALL INCLUDE THE COST OF

PROTECTION UTILITY POLES IN THEIR OVERALL PRICE TO THE OWNER.

6. ANY DAMAGE TO ROADS AND PAVEMENT DUE TO CONSTRUCTION EQUIPMENT OR

CONSTRUCTION TRAFFIC SHALL BE REPAIRED TO THEIR ORIGINAL CONDITION BY

THE CONTRACTOR AT HIS/HER OWN EXPENSE TO THE SATISFACTION OF THE

CONTRACTING OFFICER.

7. PROTECT EXISTING GEOTHERMAL WELL FIELD LOCATED APPROXIMATELY AT THE

SITING OF THE RELOCATED PICNIC SHELTER.

8. ALL EXISTING COMMUNICATION FACILITIES LOCATED UNDER AND ADJACENT TO

THE NEW BUILDING ADDITION SHALL BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION ACTIVITIES FOR THE PROJECT.

REMOVE WATER LINE

PROTECT EXISTING COMMUNICATION LINES

REMOVE AND RELOCATE STORAGE UNIT

COORDINATE WITH BASE

DEMO 4 LF CONCRETE STORM PIPE

FILL WITH GROUT

DEMOLISH EXISTING MANHOLE

AutoCAD SHX Text

SRV

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

6' CHAIN LINK FENCE

6' CHAIN LINK FENCE

4" METAL BOLLARD

TYPICALELECTRIC BELOW

GROUND VAULT

FIBER OPTIC BELOW

GROUND VAULTELECTRIC BELOW

GROUND VAULT

FIBER OPTIC BELOW

GROUND VAULT

EDGE OF PAVEMENT

CENTERLINE

7" BLOCK WALL

7" BLOCK WALL

CHILLER

AC

D

CONTROL POINT #2

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=521735.62'

EASTING=1274196.36'

ELEVATION=32.82'

CONTROL POINT #1

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=522096.68'

EASTING=1274199.63'

ELEVATION=34.01'

ONE STORY

STUCCO AND BLOCK

BUILDING 90310

F.F.E.=34.99'

BUILDING ADDITION

BUILDING 90310

F.F.E. = 34.99'

ABBREVIATIONS AND SYMBOLS

= BACKFLOW PREVENTER

= LIGHT POLE

= IRRIGATION CONTROL VALVE

= BOLLARD

F.F.E. = FINISHED FLOOR ELEVATION

(F) = VALUE DERIVED FROM FIELD SURVEY

= BENCHMARK

= CABLE TELEVISION PEDESTAL/SERVICE BOX

= POST

SRV = SERVICE BOX

= BURIED STORMWATER SEWER

= BURIED WATER LINE

SD

x

W x

= BRICK

= WALL

= CONCRETE

BM

= ASPHALT PAVEMENT

= 6" PVC ROOF DRAIN

= BURIED SANITARY SEWER (SURVEY)SS

x

= BURIED COMMUNICATIONS LINECOMM

= CHAIN LINK FENCEX

= BURIED ELECTRICAL (GIS DATA)E

x

0 20' 40'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

1 S

PE

CIA

L O

PE

RA

TIO

NS

CI

VIL

EN

GIN

EE

R S

QU

AD

RO

N

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

B U

I L D

I N

G

A

D D

I T

I O

N

146316.14

V:

\2

6\ ac tiv e\

4\ ci vil

\d ra w in g\

-d sg n\ sh ee t_ file s\

C S1

.d w g

/0 3/

:5

PM B

y:

G er th , J am es

SITE PLAN

1" = 20'

CS101

S I T

E

P

L A

N

CEB

BP

3/30/2020

PROPOSED LEGEND

BUILDING ADDITION

CONCRETE SIDEWALK

NEW 8'

SIDEWALK

NEW 4' SIDEWALK

REPLACE / EXPAND EXISTING LANDING

NEW 5' SIDEWALK

RELOCATED PICNIC SHELTER

(PROVIDE 26'x17' CONCRETE SLAB, SEE STRUCTURAL.

COORDINATE FINAL LOCATION WITH COR TO AVOID

RELOCATION OF THE GEOTHERMAL SYSTEM)

GENERAL NOTES:

1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND

SPECIFICATIONS AND THE REQUIREMENTS AND STANDARDS OF ALL GOVERNING

AUTHORITIES.

2. THE LOCATION OF UNDERGROUND FACILITIES SHOWN ON THESE PLANS IS BASED

ON INFORMATION PROVIDED BY THE UTILITIES AND SHALL BE CONSIDERED

APPROXIMATE. IT SHALL BE THE CONTRACTOR'S FULL RESPONSIBILITY TO

CONTACT THE VARIOUS UTILITY COMPANIES TO LOCATE THEIR FACILITIES PRIOR

TO STARTING CONSTRUCTION. NO ADDITIONAL COMPENSATION SHALL BE PAID TO

THE CONTRACTOR FOR DAMAGE AND REPAIR TO THESE FACILITIES CAUSED BY HIS

WORK FORCE.

3. ALL EXCESS MATERIAL SHALL BE HAULED AWAY AND DISPOSED OF

APPROPRIATELY AT THE CONTRACTOR'S EXPENSE.

4. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY

THE CONTRACTOR PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY

THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH

CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA

COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR WORK HAVING TO BE

REDONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS

IF SUCH NOTIFICATION HAS BOT BEEN GIVEN.

5. THE CONTRACTOR IS TO COORDINATE WITH THE RESPONSIBLE UTILITY PROVIDER

FOR PROTECTION/HOLDING OF UTILITY POLES, GUY WIRES AND GUY ANCHORS IN

AREAS OF CONSTRUCTION. THE CONTRACTOR SHALL INCLUDE THE COST OF

PROTECTION UTILITY POLES IN THEIR OVERALL PRICE TO THE OWNER.

6. ANY DAMAGE TO ROADS AND PAVEMENT DUE TO CONSTRUCTION EQUIPMENT OR

CONSTRUCTION TRAFFIC SHALL BE REPAIRED TO THEIR ORIGINAL CONDITION BY

THE CONTRACTOR AT HIS/HER OWN EXPENSE TO THE SATISFACTION OF THE

CONTRACTING OFFICER.

7. PROTECT EXISTING GEOTHERMAL WELL FIELD LOCATED APPROXIMATELY AT THE

SITING OF THE RELOCATED PICNIC SHELTER.

8. ALL EXISTING COMMUNICATION FACILITIES LOCATED UNDER AND ADJACENT TO

THE NEW BUILDING ADDITION SHALL BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION ACTIVITIES FOR THE PROJECT.

EXISTING LEGEND

NEW DROP INLET-2

NEW DROP INLET-3

NEW DROP INLET-4

NEW DROP INLET-1

NEW 4' SIDEWALK

NEW 5' SIDEWALK

MODIFY CATCH BASIN WITH 12" HIGH STEM WALL

SEE STRUCTURAL DETAILS SHEET S-502

NEW CONCRETE FLUME

CS201

NEW 15" MES

5'X5' RIPRAP

6'X6' RIPRAP

RIPRAP

BUILDING ADDITION

BUILDING 90310

F.F.E. = 34.99'

EJ

EJ

EJ

CJ

EJ

EJ

EJ

CJ

CJ

EJ

EJ

EJ

EJ EJ

EJ

EJ

CJ

CJ

CJ

CJ

CJ

EJ

EJ

EJ

CJ

CJ

CJ

EJ

CJ

CJ

CJ CJ CJ EJEJ

CJ

CJ

CJ

EJ

CJ

CJ

CJ

CJ

EJ

EJ

CJ

EJ EJ CJ CJ CJ

CJ

CJ

EJ

EJ

EJ

CJ

8'

11.

5'

8'

7'

15.06'

8' 15 .24

4'

19.2'

5'

.67

4'

8'

EJ

EJ

4'

5'

14'

4.3 4'

4'

R

R

R

RR

R

R

4'

REJ

EJ

EJ

R

R

RR

EJ CJ

CJ

CJ

CJ

CJ

CJ

EJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

EJ

CJ

CJ

CJ

CJ

CJ

EJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

EJ

CJ

CJ

5'

(TYP)

5'

5'

5'

R

9'

5'

9' 9'

10'

8'

3.3

7.4

CJ

3.5'

EJ

EJ

EJ

EJ

4.7

(T

YP

)EJ

R

5' 4.6

7'

4.67'

8'

EJ EJ

R

CJ

CJ

5'

EJ

EJ

EJ

EJ

EJ

EJ

CJ

CJ

5'

5'

CJ

CJ

0 10' 20'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

1 S

PE

CIA

L O

PE

RA

TIO

NS

CI

VIL

EN

GIN

EE

R S

QU

AD

RO

N

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

B U

I L D

I N

G

A

D D

I T

I O

N

146316.14

V:

\2

6\ ac tiv e\

4\ ci vil

\d ra w in g\

-d sg n\ sh ee t_ file s\

C S2

.d w g

/0 3/

:5

PM B

y:

G er th , J am es

CONCRETE JOINT PLAN

1" = 10'

CS201

C O

N C

R E

T E

J

I N

T

P

L A

N

CEB

BP

3/30/2020

PROPOSED LEGEND

BUILDING ADDITION

CONCRETE SIDEWALK

VARIES - SEE SITE PLAN

SECTION

S E

E

P

L A

N

W

1.25 X W

MAX.

36' MAXIMUM BETWEEN EXPANSION JOINTS

NOTE: PROVIDE EXPANSION

JOINTS WHERE SIDEWALK

ABUTS STRUCTURES OR

OTHER SIDEWALKS.

PLAN

CONTRACTION JOINT

1/8"

EXPANSION JOINT

1/2"

COMPACTED SUBGRADE

" 4

12"

EXPANSION JOINT

CONTRACTION JOINTS

TOOLED

EDGES (TYP.)

EXPANSION JOINT MAT'L.

TOOLED

EDGES (TYP.)

PEA GRAVEL

FILTER FABRIC

CONCRETE

SIDEWALK DETAIL

NTS

TOOLED EDGES (1/8" RAD.) (TYP)

CONSTRUCTION JOINTCJ

REINFORCED SECTIONR

EXPANSION JOINTEJ

CONCRETE JOINT PLAN

1" = 10'

5' SOD5' SOD

SIDE VIEW

24" 24"

6" CURB

2'R

PER PLANS

PLAN VIEW

2'R

FLUME DETAIL

NTS

NOTES:

1. 8' WIDE SIDEWALKS SHALL BE 6" THICK.

2. < 8' WIDE SIDEWALKS SHALL BE 4" THICK.

AutoCAD SHX Text

CURB

AutoCAD SHX Text 6.25%

AutoCAD SHX Text

PROFILE TO MATCH SITE GRADING

AutoCAD SHX Text NOTES: 1. CONCRETE SHALL BE 3000 P.S.I. @ 28 CONCRETE SHALL BE 3000 P.S.I. @ 28 DAYS 2. CHAMFER ALL EXPOSED EDGES 3/4". CHAMFER ALL EXPOSED EDGES 3/4". 3. RIP-RAP SHALL BE SUPPLIED AND RIP-RAP SHALL BE SUPPLIED AND CONSTRUCTED AS DEFINED IN THE F.D.O.T. SPECIFICATIONS SEC. 530, "RIP-RAP", SPECIFICALLY SEC. 530-3.1 OR SEC. 530-3.3 "CONSTRUCTION METHODS" 5 SY. RIP-RAP AND FILTER CLOTH TO BE INCLUDED IN THE UNIT PRICE OF THE MITERED END SECTION. 4. FILTER FABRIC SHALL BE SUPPLIED AND FILTER FABRIC SHALL BE SUPPLIED AND CONSTRUCTED AS DEFINED IN THE F.D.O.T. SPECIFICATIONS SEC. 514, PLASTIC FILTER FABRIC, SPECIFICALLY SEC. 514-3.4 RIPRAP, INCLUDED IN UNIT COST OF ENDWALL.

AutoCAD SHX Text

CURB

AutoCAD SHX Text 6"x6" WELDED WIRE FABRIC

AutoCAD SHX Text

FILTER FABRIC

AutoCAD SHX Text 6"x6" WELDED WIRE FABRIC

AutoCAD SHX Text ROCK RIP-RAP (30 LB. MIN.) EXTEND 12' OUT FROM EDGE OF CONCRETE AND MATCH WIDTH OF FLUME

AutoCAD SHX Text

6" CONCRETE SLAB

AutoCAD SHX Text

ADJACENT PAVEMENT

SRV

SRV

SRV

S D x

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CATCH BASIN

TOP= 32.98'

15" RCP S INV= 29.86'

EDGE OF PAVEMENT

CENTERLINE

D

S

S x

S

S x

S

S x

S

S x

S

Sx

W x

W x

W x

W x

W x

W xW xW x

W x W x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

S

D x

18" RCP

INV: 27.18'

12" RCP

TOP= 31.22'

INV: 27.0'±

CATCH BASIN

TOP= 30.62'

18" RCP SW INV: 28.46'

NE INV= 28.50'

STORM SEWER MANHOLE

TOP= 32.51'

12" RCP SW INV= 27.4'±

12" RCP INV= 27.3'±

S

S x

S

S x

CONTROL POINT #2

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=521735.62'

EASTING=1274196.36'

ELEVATION=32.82'

CONTROL POINT #1

SET NAIL AND DISK

"SAM LLC CONTROL POINT"

NORTHING=522096.68'

EASTING=1274199.63'

ELEVATION=34.01'

ONE STORY

STUCCO AND BLOCK

BUILDING 90310

F.F.E.=34.99'

2" METAL

ROOF DRAIN

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

S

D

S

D

S

D

S

D

S D

S D

S D

S D

S D

S D

S D

S D

S D

S D

F

F

F

F

F

F

F

F

F

F

F

F

F

F

R

D

R D

R

D

R D

R D

R D

R

D

R

D

R

D

R D

S

D

S

D

S

D

S

D

S

D

S

D

S

D

BUILDING ADDITION

BUILDING 90310

F.F.E. = 34.99'

(33)

(32)

(34)

(3 4)

(34) (34)

(34)

(34)

(34)

(33)

ABBREVIATIONS AND SYMBOLS

= BACKFLOW PREVENTER

= LIGHT POLE

= IRRIGATION CONTROL VALVE

= BOLLARD

F.F.E. = FINISHED FLOOR ELEVATION

(F) = VALUE DERIVED FROM FIELD SURVEY

= BENCHMARK

= CABLE TELEVISION PEDESTAL/SERVICE BOX

= POST

SRV = SERVICE BOX

= BURIED STORMWATER SEWER

= BURIED WATER LINE

SD

x

W x

= BRICK

= WALL

= CONCRETE

BM

= ASPHALT PAVEMENT

= 6" PVC ROOF DRAIN

= BURIED SANITARY SEWER (SURVEY)SS

x

= BURIED COMMUNICATIONS LINECOMM

= CHAIN LINK FENCEX

= BURIED ELECTRICAL (GIS DATA)E

x

0 20' 40'

N

SHEET REFERENCE:

DA

TE

SHEET NUMBER:

OF

DE

SC

RI

PT

IO

N

RE

V

AI

R

FO

RC

E

SP

EC

IA

L

OP

ER

AT

IO

NS

C

OM

M

AN

D

1 S

PE

CIA

L O

PE

RA

TIO

NS

CI

VIL

EN

GIN

EE

R S

QU

AD

RO

N

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

IA

R

E

OF R

C

SPE

C

IA

AN

N

PE

R L O

ATI

O

MM

SC

O

D

B U

I L D

I N

G

A

D D

I T

I O

N

146316.14

V:

\2

6\ ac tiv e\

4\ ci vil

\d ra w in g\

-d sg n\ sh ee t_ file s\

C U1

.d w g

/0 3/

:5

PM B

y:

G er th , J am es

UTILITY PLAN

1" = 20'

CU101

U T

I L

I T

Y

P

L A

N

CEB

BP

3/30/2020

PROPOSED LEGEND

BUILDING ADDITION

CONCRETE SIDEWALK

F F FIRE WATER MAIN

SD SD STORM DRAIN

NEW DROP INLET-1

RIM EL = 33.5'

15" INV (N) = 29.85'

15" INV (W) = 29.85'

6" INV (S) =29.8'

EXISTING LEGEND

EXISTING 4" FIRE LINE

TO REMOTE FDC

EXISTING 6" FIRE LINE

RELOCATED PICNIC SHELTER

(PROVIDE 26'x17' CONCRETE SLAB, SEE

STRUCTURAL)

NEW DROP INLET-3

RIM EL = 33.0'

15" INV (N) = 29.60'

15" INV (E) = 29.60'

8" INV (NE) = 29.60

43 LF OF 2" WATER LINE

NEW DROP INLET-4

RIM EL = 33.0'

15" INV (W) = 29.55'

8" INV (E) = 29.55'

15" INV (S) = 29.55'

NEW DROP INLET-2

RIM EL = 33.4'

15" INV (E) = 29.80'

15" INV (S) = 29.80'

6" INV (se) = 29.80

52 LF OF 15" RCP

92 LF OF 15" RCP

44 LF OF 15" RCP

ROOF DRAINS

RD RD ROOF DRAIN

CLEAN OUT (TYP)

ROOF DRAIN

ROOF DRAIN

8" PVC ROOF DRAIN

RECONNECT 2 EXISTING 6" ROOF DRAINS

RECONNECT TO EXISTING ROOF DRAINS

8" PVC ROOF DRAIN

6" PVC ROOF DRAIN

8" PVC ROOF DRAIN

CLEAN OUT (TYP)

6" PVC ROOF DRAIN

84 LF OF 6" FIRE LINE

8" PVC ROOF DRAIN

92 LF OF 15" RCP

15" MES WITH RIPRAP

INV=29.25 (RECESSED)

MODIFY CATCH BASIN WITH 12" HIGH STEM WALL

SEE STRUCTURAL DETAILS SHEET S-502

REDIRECT ROOF DRAIN

IN WALL TO WEST

8" PVC ROOF DRAIN

8 LF OF 4" FIRE LINE TO REMOTE FDC

NEW CONCRETE FLUME

CS201

1.00 GENERAL NOTES

1.01 THESE DRAWINGS ADDRESS ONLY THE STRUCTURAL DESIGN OF THE STRUCTURE. THE DIMENSIONAL LAYOUT OF THE STRUCTURE HAS BEEN DICTATED TO JOE DEREUIL ASSOCIATES IN ORDER TO PRODUCE STRUCTURAL DESIGN DOCUMENTS. NO REPRESENTATION IS MADE REGARDING CODE CONFORMANCE OF NON-STRUCTURAL ASPECTS OF THE STRUCTURE.

1.02 THESE STRUCTURAL NOTES SHALL BE APPLIED WITH THE TECHNICAL SPECIFICATIONS IN THE SPECIFICATIONS MANUAL. ANY CONFLICTING REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER FOR RESOLUTION BEFORE

PROCEEDING WITH FABRICATION OR CONSTRUCTION.

1.03 DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT SPECIFICALLY SHOWN, PROVIDE

DETAILS SIMILAR TO THOSE SHOWN.

1.04 VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY CONTRACTING OFFICER

OF ANY DISCREPANCY.

1.05 THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. TAKE NECESSARY PRECAUTIONS TO PROTECT THE EXISTING STRUCTURE AND ITS FOUNDATION AND TO LIMIT, TO THE EXTENT POSSIBLE, THE EFFECTS OF CONSTRUCTION THAT THE NEW STRUCTURE HAS ON THE

EXISTING STRUCTURE.

1.06 COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL. NOTIFY CONTRACTING OFFICER OF ANY CONFLICT AND/OR OMISSION. CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN APPROVAL OF THE CONTRACTING OFFICER. FOR ADDITIONAL OPENINGS NOT SHOWN ON

THE STRUCTURAL DRAWINGS, SEE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS.

1.07 DESIGN CRITERIA:

THE STRUCTURE HAS BEEN DESIGNED UTILIZING THE FOLLOWING REFERENCES:

A. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS

B. UFC 3-301-01, STRUCTURAL ENGINEERING

C. UFC 3-310-04, SEISMIC DESIGN FOR BUILDINGS WITH CHANGE 1

D. INTERNATIONAL BUILDING CODE, 2018

E. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES

F. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE

G. ACI 360 R-10, DESIGN OF SLABS-ON-GROUND

H. AISC 360-16, SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS

I. TMS 402/602-16, BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES

1.08 DESIGN LOADS

A. ROOF DEAD LOADS: REFER TO SECTION 7 OF THESE NOTES

B. LIVE LOADS: (MAY BE REDUCED PER CODE)

1. ROOFS: REFER TO SECTION 7 OF THESE NOTES

2. SLAB-ON-GRADE: 150 PSF

C. WIND LOADS - STRUCTURE HAS BEEN DESIGNED TO CONFORM TO THE WIND PROVISIONS OF ASCE 7-16. SEE WIND

PRESSURE DIAGRAM & CHART FOR THE FOLLOWING:

1. ULTIMATE WIND SPEED (3-SEC GUST)

2. NOMINAL WIND SPEED (3-SEC GUST)

3. BUILDING RISK CATEGORY

4. WIND EXPOSURE CATEGORY

5. INTERNAL PRESSURE COEFFICIENT

6. COMPONENT & CLADDING WIND PRESSURES

D. EARTHQUAKE LOADS:

1. SEISMIC IMPORTANCE FACTOR (Ie): 1.0

2. OCCUPANCY CATEGORY: II

3. SEISMIC DESIGN CATEGORY: B

4. MAPPED SPECTRAL RESPONSE ACCELERATIONS & PARAMETERS

Ss = 0.080g Sds = 0.085g S1 = 0.050g Sd1 = 0.080g

5. SITE CLASSIFICATION: D

6. BASIC SEISMIC-FORCE-RESISTING SYSTEM: INTERMEDIATE REINFORCED MASONRY SHEAR WALLS

7. DESIGN BASE SHEAR: 22 KIPS

8. SEISMIC RESPONSE COEFFICIENT, Cs = 0.024

9. RESPONSE MODIFICATION FACTOR(S): 3.5

10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE

1.09 SHOP DRAWING SUBMITTALS:

A. THE REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS DONE BY THE STRUCTURAL ENGINEER DOES NOT RELIEVE

THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE STRUCTURAL ENGINEER. THE REVIEW BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE ONLY. IF SHOP DRAWINGS HAVE NOT BEEN REVIEWED AND APPROVED BEFORE SUBMITTAL TO THE STRUCTURAL ENGINEER, THEY SHALL BE RETURNED WITHOUT APPROVAL.

B. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ANY AND ALL ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF ALL SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED

IN THE CONSTRUCTION DOCUMENTS.

C. CONTRACTOR IS SOLEY RESPONSBILE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF

CONSTRUCTION.

D. ALL MODIFICATIONS MADE FOR SUBMITTALS THAT ARE RE-SUBMITTED SHALL CLEARLY NOTE ALL CHANGES.

E. REPRODUCING THE CONTRACT DOCUMENTS FOR USE AS SHOP DRAWINGS IS NOT ALLOWED, AND SHOP DRAWINGS

WILL BE RETURNED WITHOUT APPROVAL.

F. GENERAL SHOP DRAWING REQUIREMENTS:

1. SUBMIT SHOP DRAWINGS AND ANY OTHER SPECIAL INFORMATION NECCESSARY FOR PROPER FABRICATION, ERECTION, AND PLACEMENT OF STRUCTURAL FABRICATIONS. INCLUDE PLANS, ELEVATIONS, AND SECTIONS.

CLEARLY SHOW ANCHORAGES, CONNECTIONS, AND ACCESSORY ITEMS. THE DETAILER MUST INTERPRET THE CONTRACT DOCUMENTS AND CLEARLY CONVEY THIS INTERPRETATION TO THE FIELD IN THE FORM OF PLACING

OR ERECTION DRAWINGS.

2. CONCRETE REINFORCING DETAILER - PROVIDE PLACING DRAWINGS FOR FABRICATION AND PLACING OF REINFORCING STEEL. THESE DRAWINGS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: BAR LISTS, SCHEDULES, BENDING DETAILS, PLACING DETAILS, PLACING PLANS, AND PLACING ELEVATIONS.

CLEARLY SHOW FOUNDATION REINFORCING. INDICATE BAR LENGTHS, LOCATION AND SPLICES OF

CONTINUOUS BARS, AND BAR SUPPORTS. CLEARLY SHOW LOCATIONS OF ALL DOWELS ON PLAN.

1.10 SHOP DRAWINGS BY SPECIALTY ENGINEER:

A. THE FOLLOWING SYSTEMS AND COMPONENTS AS A MINIMUM REQUIRE SPECIALTY ENGINEERED ERECTION AND

FABRICATION DRAWINGS WITH INPUT BY A SPECIALTY ENGINEER, BUT ARE NOT LIMITED TO: COLD-FORMED ROOF TRUSS SYSTEM, WINDOW SYSTEMS, STOREFRONT SYSTEM, ROOF SYSTEMS, AWNINGS, LOUVERS, LADDERS, AND ALL

EXTERIOR SOFFIT FRAMING.

B. THE SPECIALTY ENGINEER OR SUPPLIER SHALL DESIGN AND INSTALL THEIR COMPLETED SYSTEM IN ITS ENTIRETY TO THE PRIMARY STRUCTURE PER THE CRITERIA NOTED ON THESE CONSTRUCTION DOCUMENTS. THE SPECIALTY ENGINEER SHALL ADHERE TO ALL REQUIREMENTS OF THE APPLICABLE BUILDING CODE OR THESE NOTES, WHICHEVER IS MORE STRINGENT.

C. SHOP DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT/E.O.R. AND CALCULATIONS SHALL REQUIRE THE SEAL, DATE, AND SIGNATURE OF THE SPECIALTY ENGINEER REGISTERED IN THE PROJECT STATE.

1.11 INSPECTIONS/OBSERVATIONS:

A. SPECIAL INSPECTIONS ARE REQUIRED FOR THIS PROJECT IN ACCORDANCE WITH INTERNATIONAL BLDG CODE. REFER

TO STATEMENT OF SPECIAL INSPECTIONS, PROJECT SPECIFICATIONS AND DRAWINGS.

2.00 FOUNDATIONS AND SLAB-ON-GRADE

2.01 THE DESIGN OF FOUNDATIONS AND SLAB ON GRADE IS BASED ON THE CRITERIA ESTABLISHED IN THE GEOTECHNICAL REPORT BY UNIVERSAL ENGINEERING SCIENCES, PENSACOLA, FL; REPORT #1748816, FEBRUARY 21, 2020. THE RECOMMENDATIONS

OF THAT REPORT SHALL BE CONSIDERED AN INTEGRAL PART OF THE CONTRACT DOCUMENTS.

2.02 SHALLOW FOUNDATIONS HAVE BEEN DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 1500 PSF.

2.03 A QUALIFIED GEOTECHNICAL ENGINEER SHALL CHECK COMPACTION OF THE FOOTINGS. THE SOILS IMMEDIATELY BENEATH ALL FOOTINGS SHOULD BE COMPACTED FOR A MINIMUM DEPTH OF 12 INCHES TO A MINIMUM OF 95% OF THE SOIL’S MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D1557) USING A LARGE TAMPER. COMPACTION OF THE SOILS IMMEDIATELY BENEATH THE FOOTINGS SHOULD BE VERIFIED USING IN PLACE DENSITY TESTING AT A MINIMUM FREQUENCY OF ONE

TEST PER 75 LINEAR FEET OF STRIP FOOTING OR ON EVERY OTHER COLUMN FOOTING.

2.04 A QUALIFIED GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION AND/OR ADEQUACY OF ALL SUBGRADES, FILLS AND BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS, WALLS, FILLS, BACKFILLS, ETC. SHOULD THE CONTRACTOR FIND UNDESIRABLE SOILS, HE SHALL STOP WORK AND IMMEDIATELY CONTACT CONTRACTING OFFICER. ALL FOOTINGS SHALL REST EITHER ON UNDISTURBED SOIL OR A MANUALLY OPERATED VIBRATORY SLED OR TAMPER SHOULD BE USED TO DENSIFY ANY SOILS

IN THE BOTTOM OF THE FOOTING TRENCHES LOOSENED DURING THE EXCAVATION OPERATION.

2.05 CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY PROTECTING ALL EXCAVATION SLOPES.

2.06 DEWATER TO AT LEAST TWO FEET BELOW BOTTOM OF LOWEST FOUNDATION IF GROUNDWATER IS ENCOUNTERED.

2.07 SLAB-ON-GRADE REQUIREMENTS:

A. UNLESS NOTED OTHERWISE, THE SLAB-ON-GRADE SHALL BE A MINIMUM OF :

6 INCHES THICK, PLACED ON COMPACTED SUBGRADE, AND REINFORCED WITH #3 BARS @ 12" O.C. EACH WAY.

PROVIDE POSITIVE SUPPORT 3” CLEAR FROM BOTTOM OF SLAB. LAP MESH 12”.

B. PLACE CONTROL OR CONSTRUCTION JOINTS AT LOCATIONS INDICATED BY “S.C.J.”. SAWCUT CONTROL JOINTS AS SOON AFTER POURING AS POSSIBLE, WHEN CONCRETE WILL NOT RAVEL; 12 HRS. MAX. CURE CONCRETE IN ACCORDANCE WITH ACI 301. BEGIN CURING IMMEDIATELY AFTER POURING TO LIMIT CRACKING PRIOR TO

SAWCUTTING CONTROL JOINTS.

C. SUBGRADE SHALL BE PREPARED AS RECOMMENDED IN THE GEOTECHNICAL REPORT. IN THE ABSENCE OF A GEOTECHNICAL REPORT, THE TOP 12” OF THE SUBGRADE SHALL BE COMPACTED TO 95% OF THE MAXIMUM MODIFIED

PROCTOR DENSITY. DENSITY TESTS SHALL BE TAKEN AT 2500 SF INTERVALS.

D. VAPOR RETARDER SHALL CONFORM TO ASTM E1745, CLASS A, AND BE 10 MIL MINIMUM THICKNESS. THE VAPOR RETARDER SHOULD BE PLACED OVER THE PREPARED SUBGRADE. TO REDUCE THE POSSIBILITY OF PUNCTURE WHEN THE VAPOR RETARDER IS TO BE PLACED OVER A ROUGH GRANULAR FILL LAYER, PROVIDE A THIN LAYER OF APPROXIMATELY 1/2 INCH OF FINE-GRADED MATERIAL ROLLED OR COMPACTED OVER THE GRANULAR FILL LAYER PRIOR TO INSTALLATION OF THE VAPOR RETARDER. VAPOR RETARDER SHOULD BE OVERLAPPED 8 IN. AND TAPED AT

THE JOINTS AND CAREFULLY FITTED AROUND SERVICE OPENINGS.

3.00 REINFORCED CONCRETE

3.01 ALL CONCRETE WORK SHALL CONFORM TO ACI 301-16, SPECIFICATIONS FOR STRUCTURAL CONCRETE. DESIGN IS BASED ON ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315R-18, GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS. DETAIL ALL CONCRETE WALLS AND BEAMS ON THE SHOP DRAWINGS IN ELEVATION UNLESS SPECIFICALLY APPROVED OTHERWISE. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO

NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.

3.02 UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE THE FOLLOWING MINIMUM 28 DAY COMPRESSIVE STRENGTHS (Fc’), WATER TO CEMENTITIOUS CONTENT (W/CM):

Fc’ MAX. W/CM

A. SLAB-ON-GRADE

(EC-F0, S0, W0, C0) 3500 PSI 0.5

CONCRETE MAY CONTAIN A PROPERLY DESIGNED SUPERPLASTICIZER FOR WORKABILITY.

3.03 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.

3.04 REASONABLE MEASURES HAVE BEEN TAKEN TO MITIGATE SHRINKAGE CRACKING THROUGH THE USE OF JUDICIOUS DETAILING AND REINFORCING. HOWEVER SOME VISIBLE CRACKING IS TO BE EXPECTED AS A RESULT OF CONCRETE SHRINKAGE RESTRAINT. FURTHER MEASURES COULD BE TAKEN TO ELIMINATE ALL VISIBLE CRACKING, BUT THESE WOULD COME AT A COST IN THE FORM OF ADDITIONAL REINFORCING. ANY CRACKING THAT DOES OCCUR SHALL BE REPAIRED WITH APPROPRIATE

PROCEDURES.

3.05 THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE OWNER'S TESTING LABORATORY. RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH IS THE CONTRACTOR'S.

3.06 USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.

3.07 CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4".

3.08 TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCE DURING ALL CONSTRUCTION

ACTIVITIES. "STICKING” DOWELS INTO WET CONCRETE IS NOT PERMITTED.

3.09 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED; STAGGER SPLICE WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION SPLICES (CLASS "B") UNLESS NOTED

OTHERWISE. PROVIDE CORNER BARS FOR ALL CONTINUOUS REINFORCING.

3.10 REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS

NOTED OTHERWISE (PER ACI 318-14 TABLE 20.6.1.3.1):

A. CONCRETE AGAINST EARTH (NOT FORMED): 3"

B. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER:

1. #6 THROUGH #18 BARS: 2"

2. #5 BARS AND SMALLER: 1-1/2"

C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:

1. SLABS AND WALLS: 3/4"

2. BEAMS (STIRRUPS) AND COLUMNS (TIES): 1-1/2"

3.11 DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS APPROVED OR DIRECTED BY THE STRUCTURAL ENGINEER.

3.12 ALL REINFORCING STEEL PLACEMENTS SHALL BE REVIEWED BY THE CONTRACTING OFFICER, OR BY A REPRESENTATIVE

RESPONSIBLE TO HIM. (RE: ACI 318 PAR. 26.13.1)

3.13 FOR CONCRETE PADS SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.

4.00 STRUCTURAL STEEL, STEEL DECK

4.01 STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC 360-16 SPECIFICATION FOR

STRUCTURAL STEEL BUILDINGS.

4.02 SUBMIT SHOP DRAWINGS PREPARED IN ACCORDANCE WITH AISC MANUAL "DETAILING FOR STEEL CONSTRUCTION", LATEST EDITION. STEEL FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS. DO NOT BEGIN FABRICATION UNTIL SHOP

DRAWINGS ARE COMPLETED AND REVIEWED.

4.03 STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. STRUCTURAL STEEL SHAPES, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE C, FY = 50 KSI, UNLESS NOTED OTHERWISE.

4.04 BOLTS SHALL CONFORM TO ASTM A325, 3/4-INCH DIAMETER MINIMUM, UNLESS NOTED OTHERWISE. BOLTS IN BEARING CONNECTIONS SHALL BE DESIGNATED TYPE N, TENSIONED, SNUG-TIGHT AS DEFINED BY AISC.

4.05 USE PRE-QUALIFIED WELDED JOINTS AS PER AISC, AND AWS D1.1 "STRUCTURAL WELDING CODE." USE ONLY CERTIFIED WELDERS; ALL ELECTRODES SHALL CONFORM TO AWS A5 GRADE E70XX. BARE ELECTRODE AND GRANULAR FLUX SHALL CONFORM TO AWS A5, F70 AWS FLUX CLASSIFICATION. MINIMUM WELD SIZE TO BE 3/16" FILLET WELD, U.N.O.

4.06 CUTS, BOLTS, COPING, ETC. REQUIRED FOR WORK OR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTS OR BURNING HOLES IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED.

4.07 SHOP CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS MAY BE WELDED OR BOLTED. FIELD CONNECTIONS

NOT SPECIFICALLY DETAILED ON THE DRAWINGS SHALL BE BOLTED, WHERE POSSIBLE.

4.08 FIELD SPLICES SHALL BE DESIGNED TO DEVELOP THE FULL CAPACITY OF MEMBER AT THE POINT OF SPLICE IN BENDING, SHEAR AND AXIAL LOAD (COMPRESSION AND TENSION).

4.09 STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL AND MECHANICAL DRAWINGS AND DRAWINGS RELATED TO OTHER TRADES. CONTRACTOR SHALL BE RESPONSIBLE TO CHECK AND COORDINATE DIMENSIONS, CLEARANCES, ETC. WITH THE WORK OF OTHER TRADES. THE STRUCTURAL STEEL CONTRACTOR SHALL PROVIDE FRAMING AROUND

OPENINGS IN ROOF AS INDICATED IN THE MECHANICAL AND ARCHITECTURAL DRAWINGS.

4.10 PAINT STRUCTURAL STEEL IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. DO NOT PAINT STEEL SURFACES TO BE ENCASED IN CONCRETE, RECEIVE SPRAYED ON FIREPROOFING, CONNECTIONS DESIGNATED AS SLIP CRITICAL, OR TO BE WELDED.

STEEL DECKING:

4.11 FABRICATION AND ERECTION OF STEEL DECKING SHALL CONFORM TO THE LATEST EDITION OF THE STEEL DECK INSTITUTE'S (SDI) "SPECIFICATION AND COMMENTARY FOR COMPOSITE STEEL FLOOR DECK, NON-COMPOSITE STEEL DECK, AND STEEL ROOF

DECK" AS APPLICABLE TO THIS PROJECT.

4.12 MATERIAL FOR STEEL DECKING SHALL CONFORM TO & GRADE 50 FROM ASTM A653 OR A1063. SEE DRAWINGS FOR STEEL

DECK TYPE, GAUGE, YIELD STRENGTH AND SECTION PROPERTIES.

4.13 ROOF DECK SHALL BE TYPE B, WIDE RIB.

4.14 UNLESS NOTED OTHERWISE ALL STEEL DECKING SHALL HAVE A GALVANIZED COATING CONFORMING TO ASTM A653, G60

4.15 STEEL FLOOR DECK ANCHORAGE: REFER TO LEGEND ON PLANS

4.16 PROVIDE DECKING CONTINUOUS OVER 3 SPANS MINIMUM WHERE SUPPORTING STRUCTURE PERMITS.

4.17 STEEL DECKING SHALL BE ERECTED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S RECOMMENDATIONS

5.00 MASONRY

5.01 CONCRETE MASONRY DESIGN, CONSTRUCTION AND TESTING SHALL CONFORM TO TMS 402/602-16, BUILDING CODE

REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES.

5.02 PROVIDE LIGHTWEIGHT, HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING TO ASTM C90, UNLESS

NOTED OTHERWISE.

5.03 PROVIDE MASONRY CONSTRUCTION WITH MINIMUM COMPRESSIVE STRENGTH, f'm = 2,000 PSI.

5.04 PROVIDE TYPE "M" OR “S” MORTAR IN ACCORDANCE WITH ASTM C270 BY PROPORTION REQUIREMENTS, UNLESS NOTED

OTHERWISE.

5.05 VERTICAL CELLS SHALL BE REINFORCED WITH #5 AT 3'-4" O.C. MINIMUM, UNLESS NOTED OTHERWISE (U.N.O.) IN THE CONTRACT DRAWINGS. VERTICAL REINFORCING SHALL BE CONTINUOUS (LAPPED 48 BAR DIAMETERS MINIMUM AT SPLICES, U.N.O.)

AND HELD IN POSITION AT THE TOP AND BOTTOM OF THE GROUT POUR. U.N.O., POSITION VERTICAL REINFORCING IN THE CENTER

OF THE CELL.

NOTE: REFER TO SPECIAL INSPECTION

SPECIFICATION SECTION 01 45 35 FOR

SPECIAL INSPECTION REQUIREMENTS

IA

R

E

OF

RC

SP

EC

IA

AN

N

P

ER

L O

AT

IO

M M

S

CO

D

SHEET REFERENCE:

D A

T E

SHEET NUMBER:

OF

D E

S C

R

IP

T

IO

N R

E V

A

IR

F O

R C

E

SP

EC

IA

L O

PE

R

A

TI

O N

S C

O M

M A

N D

SP

EC

IA

L O

PE

RA

TI

ON

S

CI

VI

L

EN

GI

NE

ER

S

QU

AD

RO

N

H U

R

LB

U R

T

FI

EL

D

, F

LO

R

ID

A

PROJECT NUMBER:

BUILDING NUMBER:

DRAWN BY:

DESIGNED BY:

DATE:

90310

301 West Cervantes St.301 West Cervantes St.301 West Cervantes St.301 West Cervantes St.

Pensacola, FL 32501Pensacola, FL 32501Pensacola, FL 32501Pensacola, FL 32501 Tel. 850.429.1951Tel. 850.429.1951Tel. 850.429.1951Tel. 850.429.1951

JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC

S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA

STATE OF FLORIDASTATE OF FLORIDASTATE OF FLORIDASTATE OF FLORIDA

P.E. NO. 54319P.E. NO. 54319P.E. NO. 54319P.E. NO. 54319

C.A. NO. 9515C.A. NO. 9515C.A. NO. 9515C.A. NO. 9515

JDA PROJECT #19259

S-001

30 MAR 2020

G E

N E

R A

L N

O T

E S

WEC

WEC

OP1085747

B U

IL

D

IN

G

A D

D

IT

IO

N

D

EU

SOJ

R E

G

ISTERE

R E

E

NIGNED

EPH

ER

IL

SI

U

OL

A

DIOL

F R

STATE OF

No. 54319

E T

ACFIT

C R

E

I

3/27/20

WIND LOAD DETERMINATION ASSUMPTIONS - INTERNATIONAL BUILDING CODE 2018

ROOF SLOPE

145 C 16 3 ON 12 II ENCLOSED

ULTIMATE DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING (PSF)

ROOF ZONE 1 ROOF ZONE 2e ROOF ZONE 3

WALL ZONE 4 WALL ZONE 5

O-HANG O-HANG

34.7 -58.4 -78.1 46.6 -50.5 -62.3

50 23.7 -51.7 -63.3 41.7 -45.6 -52.6

18.9 -46.6 -56.9 39.6 -43.5 -48.4

NOTES:

1. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED,

OTHERWISE USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.

2. THE EDGE STRIP, a = 5.4 FT.

3. PRESSURES SHALL BE APPLIED IN ACCORDANCE WITH THE FIGURE SHOWN ON THIS SHEET.

< 10

> 100

ULT. WIND

VELOCITY (MPH)

EXPOSURE

CATEGORY

MEAN ROOF

HEIGHT (FT.)

RISK

CATEGORY

ENCLOSURE

CATEGORY

EFF.

AREA

(SQ. FT)

4. PRESSURES GIVEN ARE ULTIMATE LOADS TO BE USED WITH STRENGTH DESIGN. FOR

SERVICE LOADS TO BE USED WITH ALLOWABLE STRESS DESIGN, MULTIPLY THE PRESSURES

BY 0.60. SEE TABLES 2.3 AND 2.4 IN ASCE 7-16 FOR MORE INFORMATION ON LOAD

COMBINATIONS.

-90.7

-86.5

-84.7

5.06 PROVIDE GROUT FOR REINFORCED MASONRY IN ACCORDANCE WITH ASTM C476. GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE. GROUT SHALL BE FLUID CONSISTENCY. FLUID CONSISTENCY SHALL MEAN THAT CONSISTENCY AS FLUID AS POSSIBLE FOR POURING WITHOUT SEGREGATION OF THE CONSTITUENT PARTS. FILL ALL CELLS BELOW GRADE WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED AT THE TIME OF POURING BY VIBRATING AND THEN RECONSOLIDATED BY AGAIN PUDDLING LATER, BEFORE PLASTICITY IS LOST. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF THE GROUT 1-1/2 INCHES BELOW THE TOP OF THE

UPPERMOST UNIT.

5.07 PROVIDE HORIZONTAL JOINT REINFORCEMENT COMPLYING WITH ASTM A82, NO. 9 GAUGE OR HEAVIER, ZINC COATED, PLACED 16 INCHES ON CENTER UNLESS NOTED OTHERWISE.

5.08 PROVIDE RUNNING BONDS WITH VERTICAL JOINTS LOCATED AT CENTER OF MASONRY UNITS IN THE ALTERNATE COURSE

BELOW, UNLESS NOTED OTHERWISE.

5.09 ALL MASONRY UNITS SHALL BE FREE OF EXCESSIVE DUST AND DIRT AT THE TIME THEY ARE LAYED BY THE MASON.

5.10 ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS IN ALL REINFORCED MASONRY WALLS SHALL BE FULLY BEDDED IN MORTAR. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM EACH FACE OF THE UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS, BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE VERTICAL

COURSES.

5.11 PROVIDE VERTICAL CONTROL JOINTS WHERE INDICATED ON PLANS

5.12 INSPECT MASONRY MATERIAL IN ACCORDANCE WITH TMS 602-16, TABLE 3.1.2, QUALITY ASSURANCE LEVEL B.

6.00 POST-INSTALLED ANCHORS

6.01 EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES AS PROVIDED BY HILTI, INC. CONTACT HILTI AT (800) 879-8000 FOR PRODUCT RELATED QUESTIONS. EQUIVALENT SUBSTITUTES MAY BE PROVIDED FOR CONTRACTOR OFFICER REVIEW. SUBSTITUTIONS SHALL BE PROVIDED WITH CALCULATIONS

SHOWING THEY PROVIDE EQUAL OR BETTER CAPACITY THAN BASIS OF DEISGN ANCHOR.

a) ANCHORAGE TO SOLID GROUTED MASONRY

i) MECHANICAL ANCHORS USE:

(1) HILTI KWIK HUS-EZ SCREW ANCHOR PER ICC ESR-3056

6.02 ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY HILTI OR SUCH OTHER METHOD AS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE

TEMPERATURE AND INSTALLATION TEMPERATURE.

6.03 INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING AND IN STRICT

ACCORDANCE WITH THE CURRENT ICC ESR.

6.04 THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE

COMMENCEMENT OF INSTALLING ANCHORS.

6.05 ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS.

6.06 EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED ON THE DRAWINGS THAT THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, BY HILTI FERROSCAN, GPR, X-RAY, CHIPPING OR OTHER MEANS.

6.07 ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS AT THE TIME OF ANCHOR

INSTALLATION IN ACCORDANCE WITH ACI 318-14 17.1.2.

6.08 PROVIDE SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE ANCHORS PER THE APPLICABLE BUILDLING CODE AND

PER THE CURRENT ICC-ES REPORT FOR THE ANCHOR.

7.01 PREFABRICATED, PRE-ENGINEERED LIGHT-GAGE METAL TRUSSES:

7.02 TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH AISI’s “DESIGN GUIDE FOR COLD-FORMED STEEL TRUSSES.” TRUSS

COMPONENTS SHALL BE HOT DIPPED GALVANIZED.

7.03 MATERIALS: 50 KSI MINIMUM YIELD STRENGTH, G60 HOT DIPPED GALVANIZED COATING AND MINIMUM 18 GAUGE TOP CHORD.

7.04 TRUSSES AND THEIR CONNECTIONS SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER. TRUSS DESIGN CALCULATIONS & SHOP DRAWINGS SHALL BE SUBMITTED FOR ENGINEER’S REVIEW AND BOTH SHALL BE SIGNED AND SEALED BY THE PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN OF THE TRUSSES. ENGINEER SHALL BE REGISTERED IN THE PROJECT STATE. SUBMITTALS SHALL INDICATE THE APPLICABLE BLDG CODE, DESIGN WIND SPEED, DESIGN FORCES, AND REACTIONS AT BEARING POINTS. THE PLAN LAYOUT OF THE TRUSSES SHALL BE INDICATED ON THE SHOP DRAWINGS.

7.05 LIMIT VERTICAL DEFLECTION OF TRUSS TO 1/240 OF THE SPAN.

7.06 TRUSSES SHALL BE DESIGNED FOR THE POSITIVE AND NEGATIVE COMPONENTS & CLADDING WIND PRESSURES. THEY SHALL

ALSO BE DESIGNED FOR SUPERIMPOSED GRAVITY LOADS AS SHOWN:

A. TRUSS SELF-WEIGHT

B. DEAD LOAD FOR GRAVITY LOAD CASES:

1. TOP CHORD: 10 PSF

2. BOTTOM CHORD: 10 PSF

C. DEAD LOAD FOR UPLIFT LOAD CASES:

1. TOP CHORD: 5 PSF

2. BOTTOM CHORD: 5 PSF

D. ROOF LIVE LOAD: 20 PSF, REDUCIBLE PER CODE

E. WIND LOADS: COMPONENTS AND CLADDING LOADS LISTED ON THIS SHEET

7.07 TRUSSES SHALL BE SHOP ASSEMBLED.

7.08 PROVIDE BOTTOM CHORD BRACING AND OTHER BRACING AS REQUIRED BY TRUSS MANUFACTURER.

7.09 TRUSS TO TRUSS CONNECTIONS SHALL BE DESIGNED BY THE TRUSS DESIGNER. ALL CONNECTION DETAILS SHALL BE PROVIDED WITH THE SHOP DRAWINGS. SHOW SPECIFIC CONNECTION DETAILS AS REQUIRED. ALL GENERAL CONNECTION DETAILS

MUST MEET THE BEFORE-MENTIONED DESIGN…