ATTACHMENTS A-B-C-D.pdf
PDF 595 KB Posted
- Attached to
- Z1NE--Well Water Supply System Preventive Maintenance and Service Contract - Northport VAMC
- Solicitation number
- 36C24225Q0988
About this file
This document is a multi-page equipment inventory and specification set for a water supply system, containing four detailed attachments (A, B, C, and D) and a Greenheck fan equipment cut sheet. Attachment A lists well pumps, motors, and equipment located in various wellhouses, including details such as manufacturer, entry number, serial number, location, model, equipment category, maintenance frequency, and starting month. The equipment primarily consists of pumps, valves, and motors across multiple wellhouse locations, with most items scheduled for monthly maintenance starting in January.
Attachments B, C, and D provide additional inventories for booster pumps, air stripping tower components, and water treatment/disinfection components, respectively. The Greenheck fan cut sheet (USF-18-B6 model) provides comprehensive technical specifications for a universal single-width blower, including performance metrics, fan configuration, sound levels, motor specifications, and dimensional details. The blower is designed for 4,000 CFM volume, has a 5 hp motor, operates at 1,879 RPM, and is certified with AMCA ratings for sound and air performance. The document appears to be an internal inventory and equipment specification compilation for a water supply system infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24225Q0988 0002.docx | DOCX document | |
| 36C24225Q0988 0001.docx | DOCX document | |
| 36C24225Q0988_1.docx | DOCX document | |
| ATTACHMENT E.pdf | ||
| 2015-4157 NY 07.08.2025.pdf | ||
| ATTACHMENTS F AND G.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT A: WELL PUMPS/MOTORS EQUIPMENT LIST, DRAWINGS, AND SPECIFICATIONS
MFGR. EQUIPMENT STARTING
MANUFACTURER NAME ENTRY NUMBER SERIAL # LOCATION MODEL EQUIPMENT CATEGORY FREQUENCY MONTH ROCKFORD CLUTCH DIESEL GENERATO 2592 418347 WELLHOUSE-30 PTA4820PF162511 PUMP/CHEM-O-FEED[50] MONTHLY JAN WORTHINGTON #2 WELL PUMP 2598 ZZUNKNOWN WELLHOUSE-30 ZZUNKNOWN PUMP/CHEM-O-FEED[50] MONTHLY JAN
FAIRBANKS 4 INCH OSY GATE 88381309 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
RED WHITE 2 INCH GATE VAL 88381310 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
UNKNOWN 2 1/2 INCH GATE 88381311 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
MILWAUKEE 2 1/2 INCH GATE 88381312 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
UNKNOWN 1/2 INCH GATE V 88381313 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
EDDYIOWA 4 INCH CONTROL 88381314 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
UNKNOWN 1 INCH GATE VAL 88381315 WELLHOUSE-30 VALVE/WELL[50] MONTHLY JAN
JOHNSTON PUMP C JOHNSTON VERTIC 3073 2031188 WELLHOUSE-32 R267401171 PUMP/CHEM-O-FEED[50] MONTHLY JAN ROCKFORD ROCKFORD GASOLI 3074 405187 WELLHOUSE-32 PTA3815319500R9 PUMP/CHEM-O-FEED[50] MONTHLY JAN
UNKNOWN 1 INCH GATE VAL 88381316 WELLHOUSE-32 VALVE/WELL[50] MONTHLY JAN
CLAVAL 4 INCH CONTROL 88381317 WELLHOUSE-32 VALVE/WELL[50] MONTHLY JAN
JENKINS 1/2 INCH GATE V 88381318 WELLHOUSE-32 VALVE/WELL[50] MONTHLY JAN
APOLLO 2 1/2 INCH BALL 88381319 WELLHOUSE-32 VALVE/WELL[50] MONTHLY JAN
UNKNOWN 4 INCH CONTROL 88381320 WELLHOUSE-32 VALVE/WELL[50] MONTHLY JAN
FAIRBANKS 4 INCH OSY GATE 88381321 WELLHOUSE-32 VALVE/WELL[50] MONTHLY JAN
APOLLO 2 INCH BALL VAL 88381305 WELLHOUSE-74 VALVE/WELL[50] MONTHLY JAN
FAIRBANKS 4 INCH OSY GATE 88381306 WELLHOUSE-74 VALVE/WELL[50] MONTHLY JAN
JOHNSON PUMP CO #4 WELLPUMP 2593 R203913 WELLHOUSE-81 ZZUNKNOWN PUMP/CHEM-O-FEED[50] MONTHLY JAN US ELECTRIC #4 MOTOR R20392913 WELLHOUSE-81 R2674-01-171 MOTOR/WELL[50] ANNUALLY JAN
JENKINS 1 INCH GATE VAL 88381322 WELLHOUSE-81 VALVE/WELL[50] MONTHLY JAN
CLAVAL 6 INCH CONTROL 88381323 WELLHOUSE-81 VALVE/WELL[50] MONTHLY JAN
JENKINS 1/2 INCH GATE V 88381324 WELLHOUSE-81 VALVE/WELL[50] MONTHLY JAN
JENKINS 2 1/2 INCH GATE 88381325 WELLHOUSE-81 VALVE/WELL[50] MONTHLY JAN
APOLLO 2 INCH BALL VAL 88381326 WELLHOUSE-81 VALVE/WELL[50] MONTHLY JAN
FAIRBANKS 6 INCH OSY GATE 88381327 WELLHOUSE-81 VALVE/WELL[50] MONTHLY JAN
LAYNE AND BOWLE #5 WELLPUMP 2596 ZZUNKNOWN WELLHOUSE-94 ZZUNKNOWN PUMP/CHEM-O-FEED[50] MONTHLY JAN
CLOW 4 INCH GATE VAL 88381328 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
CLOW 6 INCH GATE VAL 88381329 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
UNKNOWN 1/2 INCH GATE V 88381330 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
UNKNOWN 1/2 INCH GATE V 88381331 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
CLAVAL 6 INCH CONTROL 88381332 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
CLAVAL 4 INCH CONTROL 88381333 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
CLAVAL 6 INCH CONTROL 88381334 WELLHOUSE-94 VALVE/WELL[50] MONTHLY JAN
ATTACHMENT B: INVENTORY BOOSTER PUMPS, MOTORS, EQUIPMENT LIST, DRAWINGS, AND SPECIFICATIONS
MFGR. EQUIPMENT STARTING
MANUFACTURER NAME ENTRY NUMBER SERIAL # LOCATION MODEL EQUIPMENT CATEGORY FREQUENCY MONTH UNKNOWN RPZ DEVICE 35689 UNKNOWN AIRSTRIPPER-220 825Y EQUIPMENT/AIR STRIPPER[35MONTHLY JAN PEABODY FLOWAY BOOSTER PUMP A 64576 9102051 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN PEABODY FLOWAY BOOSTER PUMP B 64577 9102049 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN PEABODY FLOWAY BOOSTER PUMP C 64578 9102050 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN ZZGENERAL ELECT BOOSTER PUMP A MOTOR 64580 RFP2612 AIRSTRIPPER-220 SKS2840NM3025 EQUIPMENT/AIR STRIPPER[35MONTHLY JAN ZZGENERAL ELECT BOOSTER PUMP B MOTOR 64581 UFG6293225 AIRSTRIPPER-220 SKS326DP60050 EQUIPMENT/AIR STRIPPER[35MONTHLY JAN ZZGENERAL ELECT BOOSTER PUMP C MOTOR 64582 RFP2612 AIRSTRIPPER-220 SKS2840NM3025 EQUIPMENT/AIR STRIPPER[35MONTHLY JAN PRATT POSITRON BLOW OFF VALVE 64591 12206 AIRSTRIPPER-220 506CD VALVE/WELL[50] MONTHLY JAN HENRY PRATT CO. BUTTERFLY VALVE A 64592 11040901 AIRSTRIPPER-220 UNKNOWN VALVE/WELL[50] MONTHLY JAN HENRY PRATT CO. BUTTERFLY VALVE B 64593 11040902 AIRSTRIPPER-220 UNKNOWN VALVE/WELL[50] MONTHLY JAN HENRY PRATT CO. BUTTERFLY VALVE C 64594 11040901 AIRSTRIPPER-220 UNKNOWN VALVE/WELL[50] MONTHLY JAN
MARLOW IND PUMP 50582 589181 UNKNOWN-116 1A1 PUMP/CHEM-O-FEED[50] MONTHLY JAN
ATTACHMENT C: INVENTORY LIST, SPECIFICATIONS OF VALVES, AIR STRIPPING TOWER COMPONENTS
MFGR. EQUIPMENT STARTING
MANUFACTURER NAME ENTRY NUMBER SERIAL # LOCATION MODEL EQUIPMENT CATEGORY FREQUENCY MONTH TWIN CITY PAN & #1 BLOWER 64566 852361 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN TWIN CITY PAN & #2 BLOWER 64570 852362 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN HYDRO GROUP TOWER #1 64584 2789811 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN HYDRO GROUP TOWER #2 64585 2789812 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN
ATTACHMENT D: WATER TREATMENT/DISINFECTION COMPONENTS DRAWINGS, SPECIFICATIONS, AND INVENTORY
MFGR. EQUIPMENT STARTING
MANUFACTURER NAME ENTRY NUMBER SERIAL # LOCATION MODEL EQUIPMENT CATEGORY FREQUENCY MONTH WALLACE & TIERN #1 CHLORINE PUMP 64562 AU15046 AIRSTRIPPER-220 44747 EQUIPMENT/AIR STRIPPER[35MONTHLY JAN WALLACE & TIERN #2 CHLORINE PUMP 64563 AU15036 AIRSTRIPPER-220 44747 EQUIPMENT/AIR STRIPPER[35MONTHLY JAN ZZGENERAL ELECT #1 CHLORINATOR MOTOR 64564 OFL211575 AIRSTRIPPER-220 ZZUNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN ZZGENERAL ELECT #2 CHLORINATOR MOTOR 64565 UNKNOWN AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN PHILADELPHIA MI #1 LIME MIXER 64571 91AAG0806 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN PHILADELPHIA MI #2 LIME MIXER 64572 91AAG0807 AIRSTRIPPER-220 UNKNOWN EQUIPMENT/AIR STRIPPER[35MONTHLY JAN
WALLACE & TIERN
LIME SLURRY METERING
PUMP
64575 AU36764 AIRSTRIPPER-220 44316M9P EQUIPMENT/AIR STRIPPER[35MONTHLY JAN
UPCOMING WATER SUPPLYSYSTEM EQUIPMENT UPGRADE INVENTORY LIST
VHANOPKOLMAJ
Stamp
| Job | Name: | USF-18-B6 | Cut | Sheet |
| Tag: | TF-1 |
| Quantity: | 1 | |||
| Printed | Date: | February | 4, | 2025 |
| Model: | USF-18-B6 | |||||||||||||
| Universal | Single | Width | Blower | |||||||||||
| Standard | Construction | Features: | Galvanized | steel | scroll | (optional | coated | steel | or | aluminum) | with | |||
| bolted | frame, | PermaLock | seam. | Centrifugal | backward | inclined | coated | steel | (optional | aluminum) | wheel. | |||
| Galvanized | (optional | coated | steel | or | aluminum) | inlet | cone. | Direct | driven | motor | mounted | out | of | the |
airstream.
Certifications/special requirements: Selected with VFD
Fan Configuration
Class I Arrangement 4
| Discharge | position UB |
| Wheel | rotation CCW |
| Fan | material Steel |
| Drive | type Direct |
Performance
| Requested | Volume | (CFM) 4,000 |
| Actual | Volume | (CFM) 4,000 |
| Total | External | SP | (in. | wg) 4 |
| Operating | frequency | (Hz) 64 |
| Fan | RPM 1,879 | |
| Operating | Power | (bhp) 3.4 |
Startup Power (bhp) 3.4
FEI 1.38
| FEP | Input | Power | (kw) 3.02 |
| Air | Stream | Temp | (F) 70 |
| Start-up | Temp | (F) 70 |
| Air | Density | (lbs/ft^3) 0.075 |
| Elevation | (ft) 100 |
| Static | Efficiency | (%) 73 |
| Outlet | Velocity | (ft/min) 2,088 |
Motor
Size (hp) 5 V/C/P 460/60/3
Short Circuit Current Rating (SCCR) 5 kA
| Fan | curve | |
| Brake | horsepower | curve |
| Operating | Point | SP |
| Operating | Bhp | point |
| Max | system | curve |
| System | curve |
1,879 FRPM
Do no t o pe ra te
| in |
| sh |
ad ed a re a
Volume (CFM) x 1000 0 1 2 3 4 5 6 7 8
St at ic P re ss ur e (in
. w g)
0.5
1.5
2.5
3.5
4.5
Br ak e Ho rs ep ow er (B
HP
0.4 0.8 1.2 1.6 2.4 2.8 3.2 3.6
Sound Octave Bands (hz) LwA dBA Sones
62.5 125 250 500 1000 2000 4000 8000
Inlet 87 83 87 84 79 76 72 69 85 74 23 Outlet 95 88 91 84 81 81 76 71 88 77 29
| Greenheck | Fan | Corporation | certifies | that | the | model | shown | herein | ||||
| is | licensed | to | bear | the | AMCA | Seal. | The | ratings | shown | are | based | on |
| tests | and | procedures | performed | in | accordance | with | AMCA | |||||
| Publication | 211 | and | AMCA | Publication | 311 | and | comply | with | the | |||
| requirements | of | the | AMCA | Certified | Ratings | Program.The | AMCA | |||||
| certified | ratings | seal | applies | to | sound | and | air | performance | and | FEI | ||
| ratings | only.Performance | certified | is | for | installation | type | B: | Free | ||||
| inlet, | ducted | outlet.Power | rating | does | not | include | transmission | |||||
| losses.Performance | ratings | do | not | include | the | effects | of | |||||
| appurtenances.The | AMCA | licensed | air | and/or | sound | performance | ||||||
| data | has | been | modified | for | installation, | appurtenances, | etc. | not | ||||
| included | in | the | certified | data. | The | modified | performance | is | not | |||
| AMCA | licensed | but | is | provided | to | aid | in | selection | and | applications | ||
| of | the | product.The | sound | power | level | ratings | are | shown | in | |||
| decibels, | referred | to | 10^-12 | watts | calculated | per | AMCA | Standard | ||||
| 301. | The | A-weighted | sound | ratings | shown | have | been | calculated | ||||
| per | AMCA | International | Standard | 301.Values | shown | are | for | inlet | ||||
| Lwi, | LwiA | and | outlet | Lwo, | LwoA | sound | power | levels | for | installation | ||
| Type | B: | free | inlet, | ducted | outlet. | Ratings | for | outlet | sound | include | ||
| the | effects | of | duct | end | correction.dBA | levels | are | not | licensed | by | ||
| AMCA | International. | The | AMCA | Certified | Ratings | Seal | for | Sound | ||||
| applies | to | inlet | Lwi, | LwiA | and | outlet | Lwo, | LwoA | ratings | only. |
| FLA | - | based | on | tables | 150 | or | 148 | of | National | Electric | Code | 2002. | Actual |
| motor | FLA | may | vary, | for | sizing | thermal | overload, | consult | factory. | ||||
| SCCR | is | a | rating | on | components | and | assemblies | representing | the | ||||
| maximum | level | of | short-circuit | current | that | a | component | or | assembly | can | |||
| withstand | without | causing | a | fire | or | shock | hazard. | A | short | circuit | |||
| exceeding | this | rating | can | cause | catastrophic | and | violent | equipment, | |||||
| component | and | enclosure | failure. |
Page 1 of 2 Version 3.10.0, January 2025
| Job | Name: | USF-18-B6 | Cut | Sheet |
| Tag: | TF-1 |
| Quantity: | 1 | |||
| Printed | Date: | February | 4, | 2025 |
Dimensions and Weights
Label Value Description
| - 18.25 Impeller | Diameter | (in) | |||||
| - 317 Weight | w/o | accessories | (lbs) | ||||
| A 39 Overall | Height | (in) | |||||
| B 35 Overall | Width | (in) | |||||
| C 44 Overall | Length | (in) | |||||
| - 23.859 Inlet | Diameter | (in) | |||||
| - 14.344 | x | 19.234 Outlet | Size | (W | x | H) | (in) |
| *All | dimensions | are | in | inches. | ||
| Page | 2 | of | 2 Version | 3.10.0, | January | 2025 |