Attachment - FCA Correction Cost Estimate.xlsx
XLSX spreadsheet 71 KB Posted
- Attached to
- C213--EL PASO FACILITY CONDITION ASSESSMENT Federal contract opportunity
- Solicitation number
- 36C25725Q0100
About this file
The provided document is an Attachment - FCA Correction Cost Estimate.xlsx, which contains a detailed assessment of the facility condition for the El Paso VA Health Care Center. The assessment covers various building systems, including architectural, IT, mechanical, and more, and provides information on the current condition, remaining useful life, and estimated correction costs. It identifies several issues that need to be addressed, such as undersized telecommunications rooms, inactive refrigerant monitoring systems, and the need for additional return air ducts. The document also references a related federal contract opportunity, "C213--El Paso Facility Condition Assessment," which is a solicitation for an independent Facility Condition Assessment (FCA) of the Central Utility Plant Building 7776 to support the El Paso VA Health Care Center. The solicitation is being issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 17.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 36C25725Q0100 0001 - Cancel Solicitation.pdf | ||
| Attachment - VA Seismic Design Reqs.pdf | ||
| RFQ 36C25725Q0100 El Paso Facility Condition Assessment.pdf | ||
| Attachment - Central Plant Drawings.pdf | ||
| Attachment - Top Ten Deficiency List.xlsx | XLSX spreadsheet | |
| Attachment - Risk Criteria.xlsx | XLSX spreadsheet | |
| Attachment - FCA Scoring Guide.xlsx | XLSX spreadsheet | |
| Attachment - FCA 101 Facility Condition Assessment Guide.pdf | ||
| Attachment - Elevator Survey_FCA.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FCA Correction Cost Estimate
| District Name | VISN | Station Number | Station Name | FCA_ID | Building No | Function Title | GSF | System | Subsystem | Useful Lifespan | Remaining Life | Correction Cost | Condition | Description | Project List | Risk Level | Pending Useful Lifespan | Pending Remaining Life | Pending Correction Cost | Pending Condition | Description |
| 4-VHA - Continental | 17 | 756 | El Paso | 314975 | 1 | Outpatient Health Care Center | Architectural | Roofs | * | * | $ 1,380 | D | FCA record added by Contractor - see detail/pending. Install fall protection at northwest corner at unprotected exhaust fan; approx. 12 lf. | 5 | 20 | exceeds | $ 105,492 | D | * Install fall protection at northwest and southwest corners at unprotected exhaust fan; approximately 24 LF. | ||
| 4-VHA - Continental | 17 | 756 | El Paso | 307507 | 1 | Outpatient Health Care Center | Information Technology | Telecommunications Rooms | 15 | $ 251,636 | F | Telecommunications rooms 103, 231, 356, 445, A304, A401, E402, A214, E202,E 303 and E118 are too small, expand rooms or relocate to locations that conform to requirements outlined in VA Space Planning Criteria Chapter 232 and OIT Design Guide Section 4 - 84. | 3 | 20 | exceeds | $ 49,304 | D | * Telecommunications Rooms have multiple deficiencies in size, condition, or bedrock VA criteria such as fire suppression, HVAC and UPS equipment support, and physical security. Installed environment is unacceptable, for example, in a mechanical room or unsecure area. Provide a study to determine cost-effective solution to either expanding rooms or relocate to locations that conform to requirements outlined in VA Space Planning Criteria Chapter 232 and OIT Design Guide Section 4 - 84. | |||
| 4-VHA - Continental | 17 | 756 | El Paso | 245231 | 1 | Outpatient Health Care Center | Mechanical | Refrigeration Equip | 23 | 11 | $ 1,432 | F | 2019 UPDATE Refrigerant monitor system is inactive and disconnected. Must be reconnected. | 5 | 25 | 7 | $ 69,273 | D | * Scherlock refrigerant leak monitoring system, model: 60-0036 is not in operation. Install new refrigerant monitoring system. | ||
| 4-VHA - Continental | 17 | 756 | El Paso | 317482 | 1 | Outpatient Health Care Center | Mechanical | Refrigeration Equip | 23 | 11 | $ 38,890 | D | 2019 UPDATE Confirmed two return ducts are undersized. Needs third return air duct, sized same as existing two ducts, routed from server room into CRAC equipment room. Each CRAC unit (2007): Liebert VH199, one 7.5 hp evaporator fan, two 14 amp compressors, R-22, 26 kW electric heat 3 stage. Outside remote condenser units are Liebert DCDF308, three 0.75 hp fans. | 3 | 25 | 7 | $ 30,757 | D | * Associated project is not currently funded. Project under design to retrofit all sixteen units and other mechanical upgrades 756-22-200 and 756-22-208. |
* Two return ducts are undersized. Needs third return air duct, sized same as existing two ducts, routed from server room into CRAC equipment room. Each CRAC unit (2007): Liebert VH199, one 7.5 HP evaporator fan, two 14 amp compressors, R-22, 26 kW electric heat 3 stage. Outside remote condenser units are Liebert DCDF308, three 0.75 HP fans. Recommend engineering study to determine path/cost to solution.
Cost est.
1. Engineer/study: 60 hours
| Accessibility |
| Air Compressor |
| Air Handling Equip |
| Archeology |
| Archeology |
| Asbestos |
| Blowoff Pit |
| Blowoff Tank |
| Blr. Feed Pumps |
| Blr. Stacks |
| Boiler |
| Bridge/Overpass |
| Building Frame-Seismic |
| Building Frame-Wind |
| Burner |
| Burner Controls |
| Chemical Pumps |
| Comb. Controls |
| Cond. Hot Well |
| Cond. Stor. Tank |
| Cond. Trans. Pumps |
| Condnste Wtr Sys |
| Condenser Water |
| Cooling twr |
| Covered Walks |
| Curb & Gutter |
| Data Processing |
| Deaerator |
| Demarcation |
| Ducts & Water Dist |
| Economizer |
| Elec/Tele Closets |
| Elevators |
| Emerg Elec Sys. |
| Emergency Electrical Systems |
| Engr. Control syst. |
| Exhaust Fans |
| Exterior Walls |
| Fencing |
| Fire Alarm |
| Fire Protection |
| Fire Sprinkler / Pump |
| Fixed Equipment |
| Fixed Research Equipment |
| Fixtures / Piping |
| Floor Systems |
| Foundations |
| Fuel Comtamination |
| Fuel Oil Pump Set |
| Fuel Oil Tank |
| Hazardous Waste |
| Heating & Ventilation |
| Heating Oil System |
| Heating System |
| Hot Water Heater |
| Incineration |
| Inlets |
| Inside Cable Plant (ICP) |
| Instruments |
| Interior Finish/Door |
| Irrigation System |
| Landscaping |
| Laundry Equipment |
| Life Safety |
| Lighting & Power |
| Lightning Protection |
| Main Computer Room |
| Mains |
| Material Handling |
| Medical Gases |
| Medical Waste |
| Mold Remediation |
| Natural Gas Systems |
| Non Structural |
| Nuclear Waste |
| Nurse Call / Intercom / TV |
| Nurse Call/Int/TV |
| Outflow |
| Outside Cable Plant (OCP) |
| Parking |
| Perimeter Walls |
| Piping |
| Primary chilled sys. |
| Primary Service |
| Primary Switchgear |
| Refrigeration Equip |
| Renewable Energy |
| Roads |
| Roofs |
| Room Air Dist/Term |
| Sea Wall |
| Secndry chill Wtr Sys |
| Secondary Distribution |
| Signage / Wayfindg |
| Signage / Wayfinding |
| Site Lighting |
| Site Planters |
| Site Security |
| Sources |
| Steam Distribution |
| Storage Tank |
| Structures |
| Structures |
| Tele/Voice Service and Switch |
| Telecommunications Rooms |
| Telephone Service |
| Telephone/Data Systems |
| Transformer |
| Vacuum Heating Pumps |
| Vehicle Fuel Station |
| Ventil (O.A. & Exh) |
| Vertical Members |
| Walks |
| Waste Removal |
| Water Feature |
| Water Softeners |
| Water Tower |
| Wayfinding |
| Windows |