Attachment D-Diagram.pdf
PDF 249 KB Posted
- Attached to
- DISTRICT 4 POLYETHYLENE BRINE TANKS
- Solicitation number
- 5400030042
- Issued by
- Richland County, South Carolina
About this file
This is a technical specification diagram for polyethylene brine and calcium chloride storage tanks procured by South Carolina's District 4. The diagram details the assembly configuration for a 5500-gallon capacity tank (model ASM TK 5500CP X 108 HD/NAT 1.5) with an 18-inch threaded and vented manway featuring 15-inch access. The specification includes seven component items: the main tank assembly, a vent assembly with mushroom head, two polyvinyl chloride (PVC) fittings with ball socket and EPDM seals, an additional UFO load fitting with natural PVC and EPDM components, an encapsulated PVC fitting with EPDM seal, and protective plastic covering. All external piping must be independently supported, and only base fittings are to remain installed at shipment per standard operating procedure. Tanks ordered with foam insulation will have an increased diameter of 4 to 6 inches, and all dimensions on rotational molded parts are subject to a 3 percent tolerance.
No pricing information, timeline details, award dates, contract terms, set-asides, or funding sources are included in this technical drawing document. The specification sheet serves as an engineering reference establishing the exact configuration and component requirements for the tank assembly to support the procurement process for District 4's brine tank acquisition.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation.pdf | ||
| Attachment E-Diagram.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
*ALL EXTERNAL PIPING MUST BE INDEPENDENTLY SUPPORTED.
*ONLY BASE FITTINGS TO BE LEFT INSTALLED AT TIME OF SHIPMENT PER SII PROCEDURE.
*TANKS ORDERED WITH FOAM INSULATION WILL HAVE AN INCREASED DIAMETER OF 4-6 INCHES.
10.0
120.0
173.2
18" THREADED/VENTED
MANWAY W/ 15" ACCESS
R45.0
8.0 10.0
90°
0°
45°135°
180°
225°
270°
315°
5 6
3 4
BRINE OR CALCIUM CHLORIDE
STORAGE TANK
ITEM
NO. QTY. PART NUMBER DESCRIPTION SHOWN TANK
CONFIG.
7 1 00000175 PROTECTIVE PLASTIC 4000-9500(120") NO YES
6 1 34700630 ASM FTG PVC 2IN ENCAP SLB BLTD/EPDM YES YES
5 1 1070000N93808 ASM FITTING UFO LD/NAT 2IN PVC/EPDM YES YES
4 2 34200015 FTG PVC 2IN BH SXT EPDM YES YES
3 1 1035000N97802 ASM VENT 18IN MUSHROOM HD/BLK YES YES
2 1 5640000N97401 ASM TK 5500CC X 120 HD/NAT 1.5 YES YES
1 1 5660000N97401 ASM TK 5500CP X 108 HD/NAT 1.5 YES YES
CUSTOMER: CUSTOMER NO:
ALL DIMENSIONS ARE IN INCHES, NOMINAL, & SUBJECT TO CHANGE WITHOUT NOTICE.
ALL DIMENSIONS ON ROTATIONAL MOLDED PARTS ARE SUBJECT TO A 3% TOLERANCE.
ReleasedSTATUS:
SHEET
ASM TK 5500CP X 108
HD/NAT 1.5
REVISION
A
ENG. ID.
TITLE:DO NOT SCALE DRAWN BY
BH
PART NO.
| Sheet1 |
| Drawing View1 |
| Drawing View2 |
File details come from the government source that posted it. Updated .