ATTACHMENT_5_-_West_Campus_Irrigation_Drawings_and_Specifications.pdf

PDF 14 MB Posted

Attached to
Valencia College Irrigation System Mainline Upgrades
Solicitation number
ITB 2025-12
Issued by
Orange County, Orlando City, Florida

About this file

This document is an irrigation construction document for Valencia College West Campus, prepared by RVI (RVi Planning) located in Tampa, Florida, dated November 14, 2024. The set of drawings (labeled IR-0 through IR-17) provides detailed technical specifications and site plans for an irrigation system mainline upgrade project. The drawings cover the entire campus area, showing proposed irrigation routes marked as IR-1 through IR-16, with detailed annotations about pipe specifications, including using purple stripe pipes for reclaimed water, HDPE DR 11 DIPS main line pipes, and 1 1/4" HDPE DR 13.5 "orange" conduit. The technical notes emphasize contractor responsibilities for coordinating mobilization, phase sequencing, and care of existing landscape and irrigation systems.

The irrigation system design incorporates specific technical requirements, such as all pipe being purple stripe for reclaimed water use, main line pipes being HDPE DR 11 DIPS, and conduit being 1 1/4" HDPE DR 13.5 "orange". The drawings include detailed installation specifications like using 3M-DBYR waterproof connects on both sides of decoders, avoiding wire path looping, and ensuring pipes are installed in open green areas with minimal disruption to existing landscaping. The project appears to be part of a broader irrigation system upgrade across multiple Valencia College campuses, focusing on replacing existing PVC mainline irrigation systems with more modern HDPE piping infrastructure.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

-2"

-2"

-2"

-2"

-2"

-2"

802"

802"

-2"

-2"

-2"

-2"

602"

602"

202"

-2"

202"

202"

202"

-2"

602"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

602"

752"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

802"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"64

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"80

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

1002"

-2"

-2"

-2"

-2"

-2"

802"

-2"

-2"

8"6"

6"

6"

6"

6"6"

3"

6"

4"

4"

3"

3"

3" 3"

3"

3"

3" 3"

3"

4"

3"

4"

4" 3"

4"

3"

3"

3"

6"

6"

6"

4"

4"

4"

6"

4"

6" 4"

6"

6"

6" 4"

4"

4"

4"

3"

4"

3"

4"

6"

6"

6" 4"

4"

3"

4" 4"

3"

4"

3"

3"

4"

4"

4"

3"

3" 4"

4"

4"

4" 4"

4"

4"

4"

3" 4"

4"

4"

4"

4" 4"

4"

4"

4"

4"

3"

3"

3"

4" 4"

4"

3"

4"

4"

3"

4"

4"

-2"

-2"

MAIN LINE FLUSH POINT &

DRAIN ACCESS

MAIN LINE FLUSH POINT,

DRAIN ACCESS AND

FUTURE EXPANSION

TWO WIRE PATH FROM CONTROLLER TO MAINLINE

MAINLINE w/TWO WIRE PATH (TYPICAL)

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

dw g

1/

/2 ja so n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

IR-0

Valencia College West

IR-1IR-2

IR-3IR-4IR-5

IR-6IR-7IR-8

IR-9IR-10IR-11

IR-12IR-13IR-14

IR-15

TYPICAL NOTES:

· IRRIGATION CONTRACTOR RESPONSIBLE FOR COORDINATING MOBILIZATION, PHASE

SEQUENCING, STAGING AREA, AND CARE OF LANDSCAPE AND CURRENT IRRIGATION

SYSTEM WITH OWNER PRIOR TO CONSTRUCTION

· THE LOCATION OF VALVES SHOWN ON PLAN WERE PROVIDED BY VALENCIA COLLEGE AND

GPS PLOTTED

· DO NOT WILLFULLY INSTALL THE IRRIGATION SHOWN ON THE DRAWINGS WHEN IT IS

OBVIOUS IN THE FIELD THAT CONDITIONS EXIST THAT MIGHT NOT HAVE BEEN

CONSIDERED IN THE DESIGN PROCESS.

· PIPING MAY SOMETIMES BE INDICATED AS BEING LOCATED IN UNLIKELY AREAS I.E.

THROUGH EXISTING TREES. THIS IS DONE FOR GRAPHIC CLARITY ONLY AND WHENEVER

POSSIBLE PIPING IS TO BE INSTALLED IN OPEN GREEN AREAS AND WHAT IS BEST FOR

EXISTING LANDSCAPING ON SITE.

· ALL PIPE TO BE PURPLE STRIPE FOR RECLAIMED WATER USE

· MAIN LINE PIPE TO BE HDPE DR 11 DIPS (PER PLAN)

· CONDUIT TO BE 1 14" HDPE DR 13.5 "ORANGE"

· ALL CONNECTIONS TO BE 3M-DBYR WATERPROOF CONNECTS ON BOTH SIDES OF THE

DECODER

· THE WIRE PATH IS NOT TO BE LOOPED

IR-16

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

FL LICENSE NO. LA6667074

HANNAH D. MCALEER, P.L.A.

-2"

6"

6" 4"

4"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

PO

LK

C

O U

N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-03

IR-1

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-04

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

4"

6"

MAIN LINE FLUSH POINT,

DRAIN ACCESS AND

FUTURE EXPANSION

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-05

IR-2

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-04

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

-2"

-2"

-2"

-2"

802"

802"

-2"

-2"

4"

4"

3"

4"

3"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

PO

LK

C

O U

N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-01

IR-3MATCH-LINE IR-06

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

602"

602"

202"

-2"

202"

202"

202"

-2"

602"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

602"

-2"

6" 4"

6"

4"

4"

4" 4"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

PO

LK

C

O U

N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-07

IR-4

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-02 MATCH-LINE IR-01

M

A

TC

H -L

IN

E

I R

-0

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

PO

LK

C

O U

N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-08

IR-5

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-02

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

8"6"

6"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

PO

LK

C

O U

N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-09

IR-6

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-03

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

752"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

802"

-2"

-2"

-2"

6"

4"

4"

4"

4"

4"

3"

3"

3"

4" 4"

4"

3"

4"

4"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-10 IR-7

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-04

M

A

TC

H -L

IN

E

I R

-0

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

-2"

-2"

-2"

-2"

6" 4"

4"

3"

4" 4"

3"

4"

3"

3"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-11

IR-8

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-05

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

-2"

-2"

-2"

-2"

-2"

6"

6"6"

3"

6"

4"

4"

3"

3"

3" 3"

3"

3"

3" 3"

3"

4"

3"

-2"

-2"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-12

IR-9

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-06

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

4"

4"

3"

4"

4"

MAIN LINE FLUSH POINT &

DRAIN ACCESS

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N 00 30' 60'

MATCH-LINE IR-13 IR-10

M A

TC

H

-L

IN

E I

R -0

MATCH-LINE IR-07

M A

TC

H

-L

IN

E I

R -1

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

4"

4"

4"

3"

3" 4"

4"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N 00 30' 60'

MATCH-LINE IR-14 IR-11

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-08

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

1002"

802"

4"

4" 3"

4"

3"

3"

6"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-15

IR-12

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-09

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

-2"

-2"

-2"

6"

6"

4"

4"

TWO WIRE PATH FROM CONTROLLER TO MAINLINE

MAINLINE w/TWO WIRE PATH (TYPICAL)

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-16 IR-13

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-10

MATCH-LINE IR-15

M A

TC

H

-L

IN

E I

R -1

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"64

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

-2"

4"

4" 4"

4"

4"

4"

3" 4"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-16

IR-14

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-11

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2" 3"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-13

IR-15

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-12

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

-2"

4"

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

N

00 30' 60'

MATCH-LINE IR-14

IR-16

M A

TC

H

-L

IN

E I

R -1

MATCH-LINE IR-13

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

REVISIONS

DRAWN:

REVIEWED:

PROJECT NO :

DATE :

10150 Highland Manor Drive Suite 450 Tampa, Florida 33510 Tel: 813.443.8282 www.rviplanning.com

C :\U se rs

\ja so n\ D ro pb ox \V al en ci a

C ol le ge

\W es t C am pu s\

W es t C am pu s

In fra st ru ct ur e.

/2 n ba rd o

VA

LE

N C

IA

C

O

LL

EG

E

EA

ST

C

AM

PU

S

PO

LK

C O

U N

TY

, F

LO

R

ID

A

#LC26000385

FLORIDA CERTIFICATE OF AUTHORIZATION

IR-17

IR

R

IG

AT

IO

N

B

ID

S

ET

N

O T

FO

R

C O

N

ST

R U

C

TI

O N

23007283 11/14/2024

GH / JVB

HM

IR

R

IG

AT

IO

N

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

FL LICENSE NO. LA6667074

HANNAH D. MCALEER, P.L.A.

SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY DETAIL

HUNTER ICV-G-R

1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE

CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT

THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL

USE. WITH RECLAIMED WATER ID, PURPLE HANDLE.

SHUT OFF VALVE HDPE

SIZED TO MATCH MAINLINE

HUNTER A2C-150D-M

150-STATION DECODER CONTROLLER WITH ONE (1) A2C-D75

MODULE IN AN OUTDOOR METAL WALL MOUNT ENCLOSURE.

HUNTER ICD-100

SINGLE STATION DECODER W/SURGE SUPPRESSION AND

GROUND WIRE. TO BE INSTALLED ON UNIVERSAL DECODER

STAKE KIT (DECSTAKE10).

GROUNDING PLATE

GROUNDING PLATE PER MANUFACTURER'S SPECIFICATIONS

POINT OF CONNECTION 10" 1

IRRIGATION MAINLINE: HDPE PE4710 DR 11

SIZED PER PLAN

20,731 L.F.

IRRIGATION SCHEDULE

Generated: 2024-08-20 18:11

P.O.C. NUMBER: 01

Water Source Information:

FLOW AVAILABLE

Point of Connection Size: 10" Flow Available 1,384 GPM

PRESSURE AVAILABLE

Static Pressure at POC: 95 PSI Pressure Available: 95 PSI

DESIGN ANALYSIS

Maximum Multi-valve Flow: 500 GPM Flow Available at POC: 1,384 GPM Residual Flow Available: 884.33 GPM

Critical Station: 3 Design Pressure: 65 PSI Friction Loss: 0.06 PSI Fittings Loss: 0.01 PSI Elevation Loss: 0 PSI Loss through Valve: 2.67 PSI Pressure Req. at Critical Station: 67.7 PSI Loss for Fittings: 1.55 PSI Loss for Main Line: 15.5 PSI Loss for POC to Valve Elevation: 0 PSI Loss for Backflow: 0 PSI Critical Station Pressure at POC: 84.8 PSI Pressure Available: 95 PSI Residual Pressure Available: 10.2 PSI

CRITICAL ANALYSIS

HDPE TRANSITION TO VALVE

NOT TO SCALE

HUNTER ICV SERIES CONTROL

VALVE PER PLAN

RAIN BIRD VB10RND VALVE BOX

HDPE MAIN LINE AND FITTINGS

FINISH GRADE

HDPE x MPT ADAPTER

SCH. 80 THREADED UNION

BRICK

2" x 6" SCH. 80 NIPPLE

GRAVEL

LATERAL PIPE PER PLAN

ISOLATION GATE VALVE

NOT TO SCALE

FINISH GRADE

PVC MALE ADAPTOR.

MAIN LINE PER PLAN

CLEAN FILL & EXPOSE VALVE

GATE VALVE PER PLAN (SAME SIZE

AS MAINLINE)

VALVE BOX EXTENSION, LENGTH AS

REQUIRED.

NOTE: ALL VALVES 3" AND LARGER SHALL BE

INSTALLED WITH OPERATING NUT ONLY.

M

IN

IM

U

M

RAIN BIRD VB10RND VALVE BOX

NOTE:

GATE VALVES ON POTABLE SYSTEM TO UTILIZE GREEN LID

GATE VALVES ON RECLAIMED SYSTEM TO UTILIZE PURPLE LID

SNAKE ALL PLASTIC PIPE

INTO TRENCHES AS SHOWN.

AND WIRING.

MAIN SUPPLY, LATERAL

36"

LATERAL

MAIN SUPPLY

14"

DETECTOR TAPE

#14-1 DIRECT BURY WIRES

INSTALLED PER MFG'S

ALL MAINLINE SHALL BE

SPECIFICATIONS.

12"

& 1.25" CONDUIT

12"

36"

PER MANUFACTURERS RECOMMENDATION.

NOTES: ALL WIRING SHALL BE

WIRING TO BE INSTALLED

IN CONDUIT

MAINLINE

LATERAL

TRENCH DETAIL

NOT TO SCALE

HUNTER ACC2 TIMER

NOT TO SCALE

MODEL AC2-75D-PP TIMER PER PLAN

4" POWER CONDUIT: SIZE, TYPE, DEPTH PER LOCAL CODE

GROUND WIRE CONDUIT, MIN. #6. BRAIDED GROUND PER

ASIC GUIDELINES 10OHMS OR LESS

PEDESTAL BASE: CONCRETE

FINISH GRADE

CONDUIT FOR SENSOR WIRES

CONDUIT FOR CONTROL WIRES

GROUND RODS (3) & PLATE (1), PROVIDE CERTIFIED

REPORT OF OHM TEST

8' MIN

10" SPLICE BOX

NOTE:

VERIFY w/PROJECT MANAGER FOR LOCATIONS

2"x4"X8" ALUMINUM POST WITH CONCRETE BASE

4 HUNTER ICD-100 DECODER

NOT TO SCALE

LEGEND:

1 ICD-100 DECODER PER PLAN

2 DECRSTAKE-10 DRIVEN INTO VALVE BOX

3 INCOMING HUNTER JACKET PER PLAN

4 RED AND BLUE WIRES

5 COPPER GROUND WIRE FROM DECODER TO GROUNDING DEVICE

6 STATION WIRE

7 IDWIRE PATH SPLICE

8 VALVE SOLENOID WIRE SPLICE

9 VALVE SOLENOID WIRE

10 OUTGOING HUNTER JACKETED IDWIRE

11 VALVE BOX

MANUFACTURER NOTES:

1. EARTH GROUND TO BE A MINIMUM OF 8' AWAY FROM DUAL-S AND AT A RIGHT ANGLE TO THE

TWO WIRE PATH

2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.

AutoCAD SHX Text Valve Number

AutoCAD SHX Text Valve Flow

AutoCAD SHX Text Valve Size

AutoCAD SHX Text Valve Callout

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
West Campus Infrastructure-IR-0
West Campus Infrastructure-IR-1
West Campus Infrastructure-IR-2
West Campus Infrastructure-IR-3
West Campus Infrastructure-IR-4
West Campus Infrastructure-IR-5
West Campus Infrastructure-IR-6
West Campus Infrastructure-IR-7
West Campus Infrastructure-IR-8
West Campus Infrastructure-IR-9
West Campus Infrastructure-IR-10
West Campus Infrastructure-IR-11
West Campus Infrastructure-IR-12
West Campus Infrastructure-IR-13
West Campus Infrastructure-IR-14
West Campus Infrastructure-IR-15
West Campus Infrastructure-IR-16
West Campus Infrastructure-IR-17

File details come from the government source that posted it. Updated .