Attachment 5 - Electrical Load Analysis AC Distribution.xlsx
XLSX spreadsheet 263 KB Posted
- Attached to
- 60ft Dive Support Boat
- Solicitation number
- N6426723Q5017
About this file
This document includes an electrical load analysis and specifications for a solicitation for a 60-foot dive support boat. The electrical load analysis provides details on the power needs for various onboard systems for the boat, including HVAC equipment, pumps, lighting, and receptacles, under different operating conditions. It analyzes the loads for 120VAC, 240VAC, and 480VAC equipment. The related solicitation seeks offers for a commercial-modified 60-foot dive support boat to be procured by the Department of the Navy Naval Sea Systems Command. Offerors must register in the System for Award Management and submit quotes in PDF or MS Word format by the response date given. The award will be made as a single purchase order to the responsible offeror whose conforming offer is most advantageous based on the evaluation criteria in the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N6426723Q5017_Amendment1.pdf | ||
| Attachment 14 - Questions and Answers.pdf | ||
| Attachment 13 - Past_Performance and Experience.doc | DOC document | |
| Attachment 10 - Delivery Schedule.xlsx | XLSX spreadsheet | |
| Attachment 2 - Specification Response Matrix.xlsx | XLSX spreadsheet | |
| Attachment 12 - CLIN Pricing Chart.xls | XLS spreadsheet | |
| Attachment 6 - Unique Item Identification.pdf | ||
| Attachment 11 - Technical Data Rights Assertion.doc | DOC document | |
| Attachment 9 - Warranty Terms.doc | DOC document | |
| Attachment 7 - DS Boat Spare Parts List.xlsx | XLSX spreadsheet | |
| N6426723Q5017_Combined Synopsis-Solicitation.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sample AC EPLA
| Summer Conditions | Winter Conditions | |||||||||||||||||||
| Shore | Transit | Dive Operations | Shore | Transit | Dive Operations | |||||||||||||||
| Description | Supplier | OEM P/N | Qty | Phase | Volts | Amps | PF | Attached Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) |
| 240VAC Loads | ||||||||||||||||||||
| Stbd #4 Main Cabin HVAC * | 1 | 1 | 240 | 0.6 | 0.6 | 0.6 | 0.5 | 0.8 | 0.8 | |||||||||||
| Pilothouse HVAC ** | 1 | 1 | 240 | 0.6 | 0.6 | 0.6 | 0.5 | 0.8 | 0.8 | |||||||||||
| D.E.R. 240VAC Receptacle | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Water Heater | 1 | 1 | 240 | 0.3 | 0.1 | 0.3 | 0.3 | 0.1 | 0.0 | |||||||||||
| Port #1 Main Cabin HVAC * | 1 | 1 | 240 | 0.6 | 0.6 | 0.6 | 0.5 | 0.8 | 0.8 | |||||||||||
| Stbd #3 Main Cabin HVAC * | 1 | 1 | 240 | 0.6 | 0.6 | 0.6 | 0.5 | 0.8 | 0.8 | |||||||||||
| Aft Deck 240VAC Receptacle #1 | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Aft Deck 240VAC Receptacle #2 | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Aft Deck 240VAC Receptacle #3 | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Main Cabin 240VAC Receptacle | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Engine Ventilation Exhaust Fan | 1 | 1 | 240 | 0.1 | 1.0 | 0.5 | 0.1 | 1.0 | 0.5 | |||||||||||
| Port #2 Main Cabin HVAC * | 1 | 1 | 240 | 0.6 | 0.6 | 0.6 | 0.5 | 0.8 | 0.8 | |||||||||||
| Port #1 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 0.2 | 0.2 | 0.2 | |||||||||||
| Port #2 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 0.2 | 0.2 | 0.2 | |||||||||||
| Stbd #3 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 0.2 | 0.2 | 0.2 | |||||||||||
| Stbd #4 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 0.2 | 0.2 | 0.2 | |||||||||||
| Pilothouse HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 0.2 | 0.2 | 0.2 | |||||||||||
| Galley HVAC *** | 1 | 1 | 240 | 0.6 | 0.6 | 0.6 | 0.5 | 0.8 | 0.8 | |||||||||||
| Galley HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 0.2 | 0.2 | 0.2 | |||||||||||
| Dive Room Exhaust Fan | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Dive Room Intake Fan | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Fresh Water Pump | 1 | 1 | 240 | 0.1 | 0.2 | 0.5 | 0.1 | 0.2 | 0.5 | |||||||||||
| HVAC Sea Water Pump | 1 | 1 | 240 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | |||||||||||
| LP Compressor | 1 | 1 | 240 | 0.1 | 0.2 | 0.5 | 0.1 | 0.2 | 0.5 | |||||||||||
| Black Water Discharge Pump | 1 | 1 | 240 | 0.1 | 0.0 | 0.0 | 0.1 | 0.0 | 0.0 | |||||||||||
| 120VAC Loads | ||||||||||||||||||||
| Port Engine Block Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.1 | 0.0 | 0.0 | 0.0 | |||||||||||
| Stbd Engine Block Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.1 | 0.0 | 0.0 | 0.0 | |||||||||||
| Lazarette Lighting | 1 | 1 | 120 | 0.1 | 1.0 | 1.0 | 0.1 | 1.0 | 1.0 | |||||||||||
| Engine Room Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | 1.0 | |||||||||||
| Engine Room Receptacles | 2 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Lazarette Receptacles | 1 | 1 | 120 | 0.1 | 0.0 | 0.0 | 0.1 | 0.0 | 0.0 | |||||||||||
| Lazarette Fan | 1 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Engine Room Lighting | 2 | 1 | 120 | 0.1 | 1.0 | 1.0 | 0.1 | 1.0 | 1.0 | |||||||||||
| Window Defogger / Head Recpt | 5 | 1 | 120 | 0.0 | 0.1 | 0.1 | 0.0 | 0.5 | 0.2 | |||||||||||
| Fwd Ventilation Fan | 1 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Galley Lighting | 2 | 1 | 120 | 0.1 | 1.0 | 1.0 | 0.1 | 1.0 | 1.0 | |||||||||||
| Galley Receptacles | 4 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Exterior Deck Lighting | 14 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Exterior Upper Deck Lighting | 3 | 1 | 120 | 0.1 | 0.1 | 0.5 | 0.1 | 0.1 | 0.5 | |||||||||||
| Bowthruster Battery Charger | 1 | 1 | 120 | 0.5 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | |||||||||||
| Dive Room Lighting | 4 | 1 | 120 | 0.1 | 1.0 | 1.0 | 0.1 | 1.0 | 1.0 | |||||||||||
| Dive Room Receptacles | 4 | 1 | 120 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.3 | |||||||||||
| Dive Equip Rm Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | 1.0 | |||||||||||
| Lazarette Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | 1.0 | |||||||||||
| Aft Deck Receptacles #1 | 2 | 1 | 120 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.3 | |||||||||||
| Aft Deck Receptacles #2 | 2 | 1 | 120 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.3 | |||||||||||
| Main Engine / Gen Battery Charger | 1 | 1 | 120 | 0.5 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | |||||||||||
| House Battery Charger | 1 | 1 | 120 | 0.5 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | |||||||||||
| Main Cabin Lighting | 2 | 1 | 120 | 0.3 | 1.0 | 1.0 | 0.3 | 1.0 | 1.0 | |||||||||||
| Galley Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 0.8 | 0.8 | 0.8 | |||||||||||
| Monkey Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | 1.0 | |||||||||||
| Refrigerator | 1 | 1 | 120 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | |||||||||||
| Fire Alarm System | 1 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Coffee Maker | 1 | 1 | 120 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | |||||||||||
| Microwave Oven | 1 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Main Cabin Receptacles | 7 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Pilothouse Receptacles | 2 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Pilothouse Lighting | 1 | 1 | 120 | 0.3 | 1.0 | 1.0 | 0.3 | 1.0 | 1.0 | |||||||||||
| TOTAL 120 and 240 VAC LOADS (kW) | ||||||||||||||||||||
| Available Power (1 Generator) | ||||||||||||||||||||
| Load as a Percentage of Available Power (%) |
| Summer Conditions | Winter Conditions | |||||||||||||||||||
| Shore | Transit | Dive Operations | Shore | Transit | Dive Operations | |||||||||||||||
| Description | Supplier | OEM P/N | Qty | Phase | Volts | Amps | PF | Attached Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) |
| 480 VAC Loads | ||||||||||||||||||||
| DER 480VAC Receptacle | 1 | 3 | 480 | 0.1 | 0.0 | 0.1 | 0.1 | 0.0 | 0.1 | |||||||||||
| Main Cabin 480VAC Receptacle | 1 | 3 | 480 | 0.1 | 0.0 | 0.1 | 0.1 | 0.0 | 0.1 | |||||||||||
| Dive Compressor | 1 | 3 | 480 | 0.9 | 0.0 | 0.9 | 0.9 | 0.0 | 0.9 | |||||||||||
| Seawater Pump / Cofferdam Eductor | 1 | 3 | 480 | 0.0 | 0.0 | 0.3 | 0.0 | 0.0 | 0.3 | |||||||||||
| Hydraulic Power Unit, 15HP | 1 | 3 | 480 | 0.0 | 0.0 | 0.3 | 0.0 | 0.0 | 0.3 | |||||||||||
| Aft Work Deck Receptacle 480VAC | 1 | 3 | 480 | 0.1 | 0.0 | 0.1 | 0.1 | 0.0 | 0.1 | |||||||||||
| TOTAL 480 VAC LOADS (kW) | ||||||||||||||||||||
| Available Power (1 Generator) | ||||||||||||||||||||
| Load as a Percentage of Available Power (%) |
| Total Loads (480VAC & 240/120VAC) (kW) |
| Available Power w/ Paralleled Generators, XXkW each (kW) |
| Load as Percentage of Available Power w/2 generators (%) |
File details come from the government source that posted it. Updated .