Oct 3 2017

JBER Lock Standards

Brand Locks utilized on JBER; Best Lock System Suggested Vendor: Best Locks All standard Office Locks must be Grade 1 locks (Office, storage closets, janitorial room etc): Cylindrical

Standard Office Locks 83K7AB4AS3626 Lockset, Heavy Duty

Storeroom Locks 83K7D4AS3626 Lockset, Heavy Duty (Communications, Electrical & Mechanical Rooms)

Where applicable the 93K Series lever handle may be used to comply with ADA specifications.

Standard Deadbolt:

Deadbolt 83T7KSTK626 Deadbolt, Tubular Deadbolt 83T7KSTK626D5 Deadbolt, Tubular, Drive In

Mortise lock Grade 1, Mortis Body Locks,“Dormitory Function” for all offices and “Store Room Function” for storage and mechanical rooms.

Mortise 45H7T4J626 Mortis Lock, “Round Knob” Mortise 45H7T15J626 Mortis Lock, “Lever Knob ADA

Mortise 45H7D4J626 Mortis Lock, “Round Knob” Mortise 45H7D15J626 Mortis Lock, “Lever Knob” ADA

Electronic Locks: (NO SUBSTITUTION ALLOWED) Dormitories

Basis G Magstripe, Cylindrical Lock, Knob (Sleeping Rooms) 83KG7DV4MSS3626

Basis G Magstripe, Mortise Lock (Common Entry to Sleeping Rooms)

45HG7TV4MS626KOS

Where applicable the 45HG7TV15MS626KOS may be used to comply with ADA specifications.

Where applicable the 93K Series may be used to comply with ADA specifications.

Basis G Magstripe, Mortise Lock (Panic Hardware) EXG7EV15-MS-626-RHR-VD9- RM-SH, Right hand Von Duprin. EXG7EV15-MS-626-LHR-VD9-RM-SH, Left hand Von Duprin.

Main Base

Main Entry To Offices:

Basis V Magstripe, Mortise Hardware Lock (45HBV7TV15MS-626-KOS-TRK-2) Where applicable they may be used to comply with ADA specifications.

Interior Office:

Basis V Magstripe, Cylindrical Lock, Knob (83KBV7DV15-MS-STK-626-TRK-2) Where applicable the 93K Series may be used to comply with ADA specifications.

Optional Basis V Magstripe, Mortise Hardware Lock (45HBV7DV15MS-626-KOS-TRK-2) Where applicable they may be used to comply with ADA specifications.

Perimeters / Stairwells:

Basis V Magstripe, Panic Hardware Lock ( EXBV7EV15-MS-626-RHR-VD9-RM-M) Where applicable they may be used to comply with ADA specifications.

Suggested Hardware: Von Duprin 99 Fire Rated Panic Hardware:

All Fire Stairwell Doors Hardware / Corridor Doors Hardware to be of Grade 1 design:

All doors to have UL listed Fire Rated Panic Hardware with no dog down feature, with outside trim to also be UL listed Fire Rated Hardware with or without key override.

Where applicable outside trim to meet ADA Standards and finish to be 626 / Satin Chrome.

Non Fire Rated Exit Hardware ( Panic ) to be of Grade 1 design:

Exit Hardware to have the capability to be locked or unlock with outside trim and be able to dog down the device from the inside with a hex key or operating key in order to leave in the passage mode when applicable. Outside trim to meet ADA Standards where applicable and finish to be 626 / Satin Chrome.

Patented Core System ( MX8 ) (NO SUBSTITUTION ALLOWED)

MX8 system to apply to all hardware that will have the capability for a key override or key access. System to be ordered as BEST 7 pin IC / 26D. Cores paid for by contractor But ordered by Lock Shop and installed by the lock shop.