This document is a technical specification for Temporary Interior Signage. It describes the requirements for fabricating and installing temporary interior signs, including the material, size, reinforcement, and attachment method. The key details are:

The signs must be fabricated from 50 Kg (110 pound) mat finish white paper, cut to 100 mm (4-inch) wide by 300 mm (12 inch) long, with a 3 mm (1/8-inch) diameter hole punched and reinforced on both sides. Steel wire 0.3 mm (0.0120-inch) thick ties are to be used to attach the signs to room door frames or knobs/levers. The signs must be marked with felt tip markers to clearly identify room numbers as designated on the floor plans. The specification outlines where the signs should and should not be installed, and requires replacing any missing, damaged, or illegible signs.

This technical specification is related to Federal Contract Opportunity f6d17e1febe84ddc8b1e891966b3ee93, Solicitation Number 36C25624R0010 issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16 for the Expand Distributed Antenna System project.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB), newest first.
File Type Posted
INTERSTITIAL LEVEL 4i AREA F1.1_recover-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E2-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA F1.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA D2.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA E1-Model.pdf PDF
INTERSTITIAL LEVEL 4i AREA G1.1-Model.pdf PDF
INTERSTITIAL LEVEL 3i AREA G2-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA G2.1-Model.pdf PDF
INTERSTITIAL LEVEL 2i AREA F1-Model.pdf PDF
LARGE SECOND FLOOR.pdf PDF
LARGE FOURTH FLOOR.pdf PDF
LARGE EIGHTH FLOOR.pdf PDF
01.BC.pdf PDF
06.M.pdf PDF
FIRST FLOOR.pdf PDF
03.HJ.pdf PDF
THIRD FLOOR-LIFE SAFETY.pdf PDF
01-BC INPATIENT - LVL.1-01.BC.1.pdf PDF
RESEARCH-FIFTH FLOOR -LIFE SAFETY.pdf PDF
FOURTH FLOOR.pdf PDF
05.L.pdf PDF
01-BC INPATIENT - LVL.5-01.5.pdf PDF
05.SUM.pdf PDF
04-K STAFF PARKING - LVL.7-04.K.7 L.S..pdf PDF
LEVEL 3.5-LIFE SAFETY.pdf PDF
01-BC INPATIENT - LVL.6-01.BC.6.pdf PDF
36C25624R0010 A0001 REVISED-6TH LEVEL -PATIENT GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-5TH LEVEL -STAFF GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-4TH LEVEL -STAFF GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-3RD LEVEL -STAFF GARAGE.pdf PDF
36C25624R0010 A0001 REVISED-1ST LEVEL -PATIENT GARAGE.pdf PDF
36C25624R0010 A0001 NOR-CC-02AR.pdf PDF
36C25624R0010 A0001 NOR-09-01AR.pdf PDF
36C25624R0010 A0001 NOR-08-04AR.pdf PDF
36C25624R0010 A0001 NOR-08-02AR.pdf PDF
36C25624R0010 A0001 NOR-07-04AR.pdf PDF
36C25624R0010 A0001 FISHER HOUSE -SECOND FLOOR-Model.pdf PDF
36C25624R0010 A0001 NOR-06-04AR.pdf PDF
36C25624R0010 A0001 NOR-03-08AR.pdf PDF
36C25624R0010 A0001 NOR-03-07AR.pdf PDF
36C25624R0010 A0001 NOR-03-05AR.pdf PDF
36C25624R0010 A0001 NOR-03-02AR.pdf PDF
36C25624R0010 A0001 NOR-02-04AR.pdf PDF
36C25624R0010 A0001 NOR-01-05AR.pdf PDF
Att 15 - DAS - Wire Mesh Partitions.docx DOCX document
Att 10 - DAS - Reference Standards.docx DOCX document
Att 8 - DAS - HEFP SEP Design Alert 12 - Design Submission Guidance for Telecommunications.pdf PDF
36C25624R0010 EXHIBIT D.docx DOCX document
Att 13 - DAS - Scope of Existing.docx DOCX document
Att 12 - DAS - Schedules.docx DOCX document
Show all 50

Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

07-01-15

SECTION 01 58 16

TEMPORARY INTERIOR SIGNAGE

PART 1 GENERAL

DESCRIPTION

This section specifies temporary interior signs.

PART 2 PRODUCTS

2.1 TEMPORARY SIGNS

A.Fabricate from 50 Kg (110 pound) mat finish white paper.
B.Cut to 100 mm (4-inch) wide by 300 mm (12 inch) long size tag.
C.Punch 3 mm (1/8-inch) diameter hole centered on 100 mm (4-inch) dimension of tag. Edge of Hole spaced approximately 13 mm (1/2-inch) from one end on tag.
D.Reinforce hole on both sides with gummed cloth washer or other suitable material capable of preventing tie pulling through paper edge.
E.Ties: Steel wire 0.3 mm (0.0120-inch) thick, attach to tag with twist tie, leaving 150 mm (6-inch) long free ends.

PART 3 EXECUTION

3.1 INSTALLATION

A.Install temporary signs attached to room door frame or room door knob, lever, or pull for doors on corridor openings.
B.Mark on signs with felt tip marker having approximately 3 mm (1/8-inch) wide stroke for clearly legible numbers or letters.
C.Identify room with numbers as designated on floor plans.

3.2 LOCATION

A.Install on doors that have room, corridor, and space numbers shown.
B.Doors that do not require signs are as follows:
1.Corridor barrier doors (cross-corridor) in corridor with same number.
2.Folding doors or partitions.
3.Toilet or bathroom doors within and between rooms.
4.Communicating doors in partitions between rooms with corridor entrance doors.
5.Closet doors within rooms.
C.Replace missing, damaged, or illegible signs.

- - - E N D - - - 01 58 16 - 1

File details come from the government source that posted it. Updated .