RESEARCH-FIFTH FLOOR -LIFE SAFETY.pdf
PDF 669 KB Posted
- Attached to
- Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) Federal contract opportunity
- Solicitation number
- 36C25624R0010
About this file
This document appears to be a Life Safety Plan for the 5th floor of a research facility. The plan provides detailed layout and construction information for the floor, including the square footage of various rooms and spaces, and designates areas for mechanical, electrical, and life safety equipment. It identifies the occupancy classification, construction type, and exit capacity for the level. The plan also includes a detailed legend and notes regarding fire-resistance ratings, smoke barriers, and travel distances. This document does not contain any information about a federal contract opportunity. The attached federal contract opportunity is for a project to expand a Distributed Antenna System at a Department of Veterans Affairs facility, but it is not directly related to the Life Safety Plan provided.
View the file
Other files for this federal contract opportunity
Show all 50
Z1DZ--Project #629-18-114 Expand Distributed Antenna System (DB) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
UP
DN
DN
DN
DN
EMER
ELEC
5P101
ELEC
SW
GEAR
5P100
MECH
PENT
5P102
FEC-W
FEC-W
FEC-W
FEC-W
FEC-W
VEST
5P200
ELEV
PS-01
UP
T
T
5P104
13450 S.F
5P102
1956 S.F
5P100
1122 S.F
5P101
1009 S.F
5P304
281 S.F
5P302
594 S.F
5P300
1259 S.F
MECHANICAL
5P-CO47
TOWER
ACCESS
5P-CO49
UNOCCUPIED
5P-CO46
STAIR
5STP1
STAIR
5STP2
194'
122'
F
F F
F
260' F
F
2-HR ELECTRICAL
RISER SHAFTS
ROOF
ROOF
a b
P
P
E
K
CM
CM
I/O
I/O
I/O
3 3 3
3 4
3 4
3 4
3 4
3 4
S S S S S
S S S S S
S S S
F
SMOKE PARTITION
GLASS/SPRINKLER 2-HOUR ASSEMBLY (DOUBLE LINE)
GLASS/SPRINKLER 1-HOUR ASSEMBLY (SINGLE LINE)
1-HOUR RATED WALL
2-HOUR RATED WALL
3-HOUR RATED WALL
4-HOUR RATED WALL
1-HOUR SMOKE BARRIER
2-HOUR SMOKE BARRIER
MAXIMUM PERMITTED TRAVEL DISTANCE
FIRE EXTINGUISHER
STANDPIPE HOSE OUTLET
EXIT FLOW AND CAPACITY0
SYMBOL KEY
NOTE 1: DETAILED OCCUPANT LOAD AND EXIT CAPACITY CALCULATIONS
ARE PROVIDED IN THE FIRE PROTECTION AND LIFE SAFETY
ANALYSIS.
NOTE 2: FURTHER DESCRIPTION REGARDING THE BUILDING
CLASSIFICATIONS, CONSTRUCTION TYPES AND FIRE
RESISTANCE RATED/SMOKE BARRIER WALLS IS INCLUDED IN
THE NARRATIVE AND THE FIRE PROTECTION AND LIFE SAFETY
ANALYSIS.
NOTE 3: NFPA 45 LAB CLASSIFICATION
2A = D
2B = D
3A = D
3B = D
4A = D
CAMPUS KEY PLAN
C
INCIDENTAL USE: CONFERENCE ROOM - OCC.
LOAD FOR ROOM CALCULATED AS 15 SF PER
OCCUPANT, LESS THAN 50 OCCUPANTS.
ALL LIFESAFETY SYMBOLS DO NOT APPEAR ON LIFESAFETY PLANS
CONSTRUCTION TYPE
ELEMENT IBC = 1B NFPA 220
STRUCT FRAME 2 HR 2
BEARING WALL 2 HR 2
2 HR 2
NON-BEARING EXT WALL TABLE 602 0
NON BEARING INT WALL 0 0
FLOOR CONST 2 2
ROOF CONSTR 1 1
TABLE 601
SEE PAGE 87 OF IBC FOR DETAIL.
Revision 12-26-18
B
STB
S.C.
1B.1
BUSINESS
P
S
B
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2
M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2
R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
BLDG 08 LIFE SAFETY PLANS
ML MLJuly 16, 2012
08100342.00SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
"=1'-0"
BLDG 08 LEVEL 5 LIFE SAFETY PLAN
OCCUPANCY
CONSTRUCTION TYPE
EXIT CAPACITY
OCCUPANT LOAD
MAX.TRAVEL DIST.
PERMITTED
S
II (222)
400' - 0"
RESEARCH #08
THIS LEVEL IS MECHANICAL
PENTHOUSE
ONE INCH = FORTY FEET (1" = 40')
0' 15' 30' 0' 40' 80'
GRAPHIC SCALE
OVERSIZED DOOR KICK PLATES
12-26-18
File details come from the government source that posted it. Updated .