Appendix F - All fuse table section 4.2.3.2.pdf

PDF 68 KB Posted

Attached to
H261--Triennial Electrical Distribution System Testing Federal contract opportunity
Solicitation number
36C25021Q1081
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This document outlines a scope of work for a federal contract solicitation to provide inspection, testing, and maintenance services for the electrical power distribution system at the Department of Veterans Affairs LTC Charles S. Kettles VA Medical Center in Ann Arbor, Michigan. Key requirements include providing qualified electrical contractor professionals certified by the InterNational Electrical Testing Association to inspect, test, maintain, and calibrate equipment such as transformers, switchgears, switchboards, panels, and generators. Services also include performing ground resistance testing, infrared scanning, lubricating and exercising circuit breakers, calibrating relays, training staff on electrical safety, and participating in a 4-hour power outage test. The contractor must submit reports on all work completed and any deficiencies found within 7 days of completion.

View the file

Other files for this federal contract opportunity

Other files attached to H261--Triennial Electrical Distribution System Testing, newest first.
File Type Posted
36C25021Q1081 0001.docx DOCX document
Electrical Testing_VA Map.pdf PDF
Appendix E - Campus Electrical one line drawings.pdf PDF
Appendix E - Campus Electrical one line drawings MAP.pdf PDF
Appendix D - Equipment summary by drawing.xlsx XLSX spreadsheet
36C25021Q1081.docx DOCX document
Appendix C - Electrical Testing - Proposed Scheduled Outages.pdf PDF
Appendix F - All breaker summary section 4.2.1.1.pdf PDF
Appendix F - All relay table section 4.2.2.2.pdf PDF
Appendix D - Inventory of Items Tested_Previous Ks.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Protection Type (Multiple Items) LTPU LTPU

EXISTING SETTINGS RECOMMENDED SETTINGS

OVERCURRENT PROT. DEV. MANUFACTURER MODEL FRAME SIZE (AMPS) CURRENT RATING CURRENT RATING

1BE DISC TRASH COMP FUSE G.SHAWMUT TRS FUSE 30 30

B1E CART WASH FUSE G.SHAWMUT TR FUSE 30 15

B1E XFMR SUB 1‐1‐01 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 125 125.0

B1E XFMR SUB 1‐1‐02 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 125 125.0

B1E XFMR SUB 1‐1‐03 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 100 100.0

B1E XFMR SUB 1‐1‐04 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 125 125.0

B1E XFMR SUB 1‐1‐05 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 125 125.0

B1E XFMR SUB 1‐B‐01 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 10 10.0

B1W DISC 1 AHU FUSE BUSSMANN FRN‐R FUSE 200 200

B1W DISC 1 AHU FUSE0 BUSSMANN FRN‐R FUSE 100 100

B1W DISC 1 AHU FUSE1 BUSSMANN FRN‐R FUSE 40 40

B1W FUSE AH‐2 SF‐2 BUSSMANN FRS‐R FUSE 100 100

B1W FUSE AH‐2E EF‐2 BUSSMANN FRS‐R FUSE 70 70

B1W MECH PENTHOUSE FUSE G.SHAWMUT TRS FUSE 100 100

B1W MTR CU1 FUSE BUSSMANN FRN‐R FUSE 100 100

B1W MTR CU2 FUSE G.SHAWMUT TR FUSE 100 80

B1W MV UNIT SUB 1 FUSE CUTLER‐H CLE‐1 & CLE‐2, 2.75‐5.5kV E‐Rated 125 125

B1W MV UNIT SUB 2 FUSE CUTLER‐H CLE‐1 & CLE‐2, 2.75‐5.5kV E‐Rated 125 125

B1W MV UNIT SUB 3 FUSE CUTLER‐H CLE‐1 & CLE‐2, 2.75‐5.5kV E‐Rated 125 125

B1W MV UNIT SUB 5 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 100 100

B1W MV XFMR UNIT SUB 6 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 50 50

B1W NOT LABELED FUSE G.SHAWMUT TRS FUSE 200 125

B1W PNL 4EPP1 BKR G.SHAWMUT TRS FUSE 100 100.0

B1W PNL 4EPP1 FUSE G.SHAWMUT TRS FUSE 100 100.0

B1W PNL 4PP1 BKR0 G.SHAWMUT TRS FUSE 200 125.0

B1W PNL ADP‐2 FUSE G.SHAWMUT TR FUSE 60 60.0

B1W SWBD ACP‐1 MAIN FUSE EDISON ECNR, Class RK5 350 350.0

B1W UNIT 4 SUB XFMR PRI FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 30 30.0

B2 BUILDING 2 MAIN FUSE G.SHAWMUT TR FUSE 200 200.0

B22 DISC EF‐1 FUSE BUSSMANN FRN‐R FUSE 20 20

B22 DISC EF‐2 FUSE BUSSMANN FRN‐R FUSE 20 20

B22 DISC EF‐2 FUSE0 BUSSMANN FRN‐R FUSE 60 60

B22 DISC EF‐2 FUSE1 BUSSMANN FRN‐R FUSE 60 60

B22 ERMG LT & FA DISC FUSE BUSSMANN FRN‐R FUSE 100 100

B22 SWBD DP FUSE G.SHAWMUT A4BY FUSE 1200 1200

B22 XFMR FUSE CUTLER‐H CLE, 15.5kV E‐Rated 80 80

B28 CP CHILLER 1 FUSE BUSSMANN FRS‐R FUSE 150 150

B28 CP HRU‐1 FUSE BUSSMANN FRS‐R FUSE 45 45

B28 DISC AHU‐1 FCF‐1 FUSE BUSSMANN FRS‐R FUSE 9 9

B28 DISC ATS B FUSE G.SHAWMUT TR FUSE 60 60

B28 DISC ATS C FUSE G.SHAWMUT TR FUSE 60 60

B28 DISC EF‐6 FUSE BUSSMANN FRS‐R FUSE 3 3

B28 DISC EM PWR FEED FUSE EDISON ECSR 400 400

B28 DISC HPA FUSE G.SHAWMUT TR FUSE 60 60

B28 XFMR NURSING HOME FUSE CUTLER‐H CLE, 15.5kV E‐Rated 125 125

B29 DISC ACU‐1‐AC FUSE BUSSMANN FRS‐R FUSE 10 10

B29 DISC ACU‐1‐AH FUSE BUSSMANN FRS‐R FUSE 10 10

B3 1A MAIN FUSE BUSSMANN FRN‐R FUSE 400 400.0

B3 ELEVATOR FUSE G.SHAWMUT TR FUSE 100 80.0

B3 PNL A,B,C ECB FUSE BUSSMANN FRN‐R FUSE 200 200.0

B3 PNL AA FUSE BUSSMANN FRN‐R FUSE 100 100.0

B3 PNL C DISC SW FUSE BUSSMANN FRN‐R FUSE 90 90.0

B3 PNL LP‐BB FUSE ‐ ‐ 0 0

B3 PNL LP‐BB FUSE BUSSMANN NON, 250V Class H 100 0

B3 SFTY SW PNL A FUSE BUSSMANN FRN‐R FUSE 90 90.0

B3 SFTY SW PNL B FUSE BUSSMANN FRN‐R FUSE 90 90.0

B31 XFMR T‐1 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 40 40.0

B31 XFMR T‐2 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 30 30.0

B31 XFMR T‐3 FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 15 15.0

B32 DISC EF‐3 FUSE ‐ ‐ 0 0.0

B32 CHILL SUB 1 FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 300 300.0

B32 CHILL SUB 2 FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 300 300.0

B32 CHILLER 1 DISC FUSE G.SHAWMUT CS‐3, 15.5kV E‐Rated 175 175.0

B32 CHILLER 1 FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 200 200.0

B32 CHILLER 2 DISC FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 200 200.0

B32 CHILLER 2 FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 200 200.0

B32 CHILLER 3 DISC FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 200 200.0

B32 CHILLER 3 FUSE G.SHAWMUT CS‐3, 5.5kV E‐Rated 200 200.0

B32 DISC 32‐P‐3H FUSE BUSSMANN FRS‐R FUSE 200 200.0

B32 DISC AC‐1 FUSE BUSSMANN FRS‐R FUSE 45 45.0

2019 E44 Electrical Evaluation ‐ 100% Submission

All Fuse Table ‐ Section 4.2.3.2 Ann Arbor VAMC ‐ Ann Arbor, MI

EXISTING SETTINGS RECOMMENDED SETTINGS

OVERCURRENT PROT. DEV. MANUFACTURER MODEL FRAME SIZE (AMPS) CURRENT RATING CURRENT RATING

B32 DISC CP‐1 FUSE ‐ ‐ 0 0.0

B32 DISC CP‐3 FUSE ‐ ‐ 0 0.0

B32 DISC DC‐1 FUSE ‐ ‐ 0 0.0

B32 DISC DOOR CTRL PNL FUSE BUSSMANN FRS‐R FUSE 4 4.0