Attach_05__Fire_Control_Plan.docx

DOCX document 18 KB Posted

Attached to
SOLICITATION POSTED Federal contract opportunity
Solicitation number
AG-82BH-S-15-0025
Issued by
Department of Agriculture Forest Service R2-Rocky Mountain Region

About this file

Attach 05 Fire Control Plan

View the file

Other files for this federal contract opportunity

Other files attached to SOLICITATION POSTED, newest first.
File Type Posted
AG-82BH-S-15-0025_Sugar_Creek_Pre-Proposal_Q_ _A's.docx DOCX document
AG-82BH-S-15-0025_Sol_cont.doc DOC document
Attach_02_Standard_FS_Trail_Specifications.pdf PDF
Attach_01_Supp_Specs_Sugar_Creek_Trail_ _Bridge.pdf PDF
AG-82BH-S-15-0025_Sol_SF_1442_pgs_1-3.pdf PDF
Attach_03_Sugar_Creek_Drawings.pdf PDF
Attach_04_General_Decision_CO12.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 05 Page 1 of 2

EMERGENCY CONTROL - FIRE PLAN

This plan outlines the channels of responsibility for fire prevention and suppression activities and sets up an attack procedure in the event of a fire within the project area. The project area is defined as the area within the National Forest and within one-half mile of the project right-of-way, work areas, and all roads used for construction purposes.

A. Tools and Equipment

1. Tools.

(a) The contractor shall furnish and maintain in a serviceable condition one shovel or pulaski for each of his employees, to be used only for suppressing forest fires. These tools will be kept in sealed boxes and available within the immediate working areas.

(b) The contractor shall furnish one shovel, LHRP, size 0 or larger, one ax, two pound or larger, for each truck, each personnel vehicle, each tractor, and each grader. For each welder, he shall furnish one shovel, LHRP, size 0 or larger, and one backpack, five-gallon pump; for each gasoline power tool (power saw, soil auger, etc.), one shovel, LHRP, size 0 or larger, and one eight-ounce chemical pressurized fire extinguisher. Contractor shall also furnish any other equipment called for elsewhere in the contract.

(c) All fire tools and equipment required to be furnished by the contractor shall be in good working condition at all times.

2. Equipment. Prior to the beginning of each fire season, the contractor shall furnish a list of equipment used on the project, on forms provided by the Forest Service.

3. Manpower. The contractor shall furnish a list of supervisory personnel and amount of manpower available on the project on forms furnished by the Forest Service. Changes in supervisory personnel and amount of manpower shall be reflected in amendment to the list.

B. General Provisions

1. Fire Prevention

(a) Burning, Blasting, or Welding. During the period from April 15 through November 15, advance approval in writing will be required and will contain special stipulations pertinent to the particular job. The District Ranger may give, in writing, seasonal approval with stipulations for blasting and/or welding. At no time will use of detonating cord be allowed in clearing operations. At all times, explosives will be stored in a locked box marked "Explosives." All Federal, State and local laws concerning the use and storage of explosives shall be complied with.

(b) Spark Arrestors. All diesel or gasoline operated engines, except those machines equipped with exhaust driven turbochargers, and all flues used on the project and in construction camps shall be equipped with adequate, serviceable arresting devices that meet Forest Service Standard 5100-1, Spark Arrestors for Internal Combustion Engines. Information in this standard will be furnished upon request.

(c) Lunch and Warming Fires. Permits will be issued by the District Ranger or his representative specifying conditions for lunch and warming fires during the period april 15 through November 15.

(d) Smoking. The contractor may permit smoking by his employees from April 15 through October 31, but only in safe places such as: along roads, in truck cabs, or where all inflammable material has been cleared away from an area at least three feet in diameter. During periods of high fire danger, smoking may be prohibited by the District Ranger except in truck cabs and at places of habitation. Under no circumstances will smoking be permitted during the period of April 15 through October 31 while operating tractors or other open-type vehicles in areas not cleared to mineral soil, or while walking or working in such areas.

(e) Power Saws. Gas and oil will be carried only in metal safety cans.

(f) Storage and Parking Areas. Equipment service areas, parking areas, gas and oil drum storage areas, and explosive storage areas will be cleared of all inflammable material for a distance of 50 feet. Small stationary engine sites shall be cleared of all inflammable material for a distance of 15 feet. Inflammable and explosive storage areas will be labeled as such and "No Smoking" signs erected.

(g) Oil Filters, Cartridges, Oily Rags. Used and discarded oil filters, cartridges, and oily rags or waste will be buried in mineral soil or burned in a safe area. Glass jugs or bottles will not be used for gas, oil, or water.