Triangle Environmental Lead Risk Assessment March 2015

Environmental Science and Engineering Inc.

P.O. Box 1026

Rolla, MO 65402

LEAD RISK ASSESSMENT

OF

Mark Twain National Forest Roby Ranger Station

Roby, MO

March 2015

FOR

Mark Twain National Forest and

Janet Fraley

TRIANGLE

evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B" evalade Typewritten Text evalade Typewritten Text

Triangle Environmental Lead Risk Assessment March 2015

TABLE OF CONTENTS

EXECUTIVE SUMMARY

1.0 LEAD IDENTIFICATION REEVALUATION SURVEY

1.1 Environmental Testing/Methodology

1.1.1 Painted Surface

1.1.2 Dust

1.1.3 Soil

2.0 SCOPE OF WORK

3.0 SUBJECT PROPERTY INFORMATION

4.0 LEAD RISK ASSESSMENT

4.1 Painted Surface

4.2 Dust

4.3 Soil

5.0 ANALYTICAL DATA

6.0 INTERIM OPTIONS

7.0 ABATEMENT OPTIONS

8.0 QUALIFICATIONS

9.0 LIMITATIONS

APPENDICES

A Missouri Department of Health and Senior Services, Risk Assessor License B Lead Inspection Record, Chain of Custody, and Analytical Results evalade Typewritten Text evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

EXECUTIVE SUMMARY

On March 20th 2015 Triangle Environmental Science and Engineering Inc, was contacted by Janet Fraley to conduct a Lead Risk Assessment on the subject property known as the Mark Twain National Forest, Roby Ranger Station, MO. Two (2) structures were inspected and assessed on the subject site. The structures inspected :

Ranger Station, Roby, MO Garage, Roby, MO

The recently conducted Lead Risk Assessment used guidance from the Missouri Revised Statute Chapter 701, State Standards, Section 701.304, ASTM E 2115 -06 “Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of other Child-Occupied Facilities”, and the United States Department of Housing and Urban Development, 24 CFR Subtitle A, § 35.1320 Lead-based paint inspections and risk assessments.

Structure: Built prior to 1978

The visual inspection revealed all exterior windows and trim to be in extremely poor condition with excessive peeling of paint. Exterior walls of the structure inspected are extremely poor condition with excessive peeling of paint. Collected soil and paint samples were analyzed for total lead content. Dust Wipe samples were analyzed for concentrations/ft2. All dust wipe samples were collected from hard, cleanable surfaces. Soil was grass covered with bare patches. Soil samples were obtained from the top ½ inch of surface.

Lead Risk Assessment

MTNF INSPECTOR JOHN CABLE

LEAD PAINT INSPECTION CERT# 120209-300003721

DATE 3/20/2015

BUILDING

RESIDENTIAL STRUCTURE, POTOSI, MO

SAMPLE LOCATION MATERIAL RESULTS

1 LIVING RM W-SILL DUST WIPE 850ug/ft2

2 Living room window trough PAINT CHIPS 11%

3 KITCHEN W SILL DUST WIPE 31ug/ft2

4 Kitchen window trough PAINT CHIPS 0.56%

5 BEDRM W SILL DUST WIPE 140 ug/ft2

6 BEDRM W SILL PAINT CHIPS 3.1%

7 BEDRM W SILL DUST WIPE 8700 ug/ft2

8 BEDRM window trough PAINT CHIPS 1.2%

9 KITCHEN FLOOR DUST WIPE 36 ug/ft2

10 HALL FLOOR DUST WIPE 33ug/ft2

11 BASEMENT FLOOR DUST WIPE 820 ug/ft2

12 Living Room window Paint chips 1.6% weight

13 Garage exterior Paint Chips 19 % weight

14 Living Rm window Sill Paint Chips 0.21% weight

15 Bedroom Window Paint Chips 7.2% weight

16 Bedroom Window Paint Chips 0.076% weight

17 BASEMENT WALL CHIPS 0.34 % weight

SOIL

GARAGE FLOOR

EXTERIOR 10 ALIQUOTE

DUST WIPE

SOIL

5500 ug/ft2 47ug/gram evalade Typewritten Text evalade Typewritten Text evalade

ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

Risk Assessment clearance standards

DUST

SILLS 250 ug/FT2 TROUGHS 400ug/FT2 FLOORS 40 ug/FT2

SOIL

PLAY AREAS 400 ug/gram ALL OTHER 1200 ug/gram

PAINT 0.5% BY WEIGHT

Conclusions-

Three (3) window sill dust wipe sample exceeded HUD Standards (250 µg/ft2).

ALL (4) Collected floor dust wipe sample exceeded HUD Standards (40 µg/ft2).

No Soil sample exceeded HUD Standards 400 ug/gr or 1,2000 micrograms/gram

Seven (7) Paint Chip Samples exceed HUD standards (0.5% by weight).

ABATEMENT OPTIONS

Wet clean all contaminated surfaces thoroughly. Workers should wear disposable coveralls, shoes, hair covering, goggles, and a respirator approved by NIOSH (the National Institute of Occupational Safety and Health). Approved respirators will have an approval number on them, (i.e., TC- 21C-xxx). Only HEPA (High Efficiency Particulate Air) respirators will filter lead dust and fumes.

Simple paper or fabric dust masks will NOT protect a worker from lead dust.

Encapsulate all exterior surfaces. These materials are applied over lead-based paint to seal the paint to a surface and prevent the release of paint chips or dust. The material may be either a liquid or an adhesive. Encapsulation provides a barrier between the paint and the environment.

Enclosure of all lead painted components.

Removal of paint by a lead abatement professional.

Complete removal of all lead painted component (windows, trim, exterior boards, etc).

At present there is no “Lead Hazard Control Plan” in effect at the site. It is recommended that the Mark Twain National Forest Service establish a plan and publicize it to the inhabitants or workers. The plan should emphasize the importance of frequent cleaning of all horizontal surfaces in the units especially the window sills and floors and should constitute an acceptable abatement plan for the facility. It does not appear that a formal training program for the facility management is necessary.

3/30/2015_

John W. Cable Date President evalade

1.0 LEAD RISK ASSESSMENT

The visual inspection was conducted in accordance with, E 2255, Practice for Conducting Visual Assessments for Lead Hazards in Buildings, to identify suspected lead hazards. The visual inspection was conducted:

to ensure each potential friction surface was assessed for evidence of abrasion to ensure each potential impact surface was assess for damaged paint to ensure each potential chewable surface was assessed for damaged paint

All exterior windows and trim were in extremely poor condition with paint peeling or non-existent. Exterior surfaces were in extremely poor condition with excessive peeling of paint. Interior surfaces had extensive evidence of peeling paint, cracking paint, or areas of deterioration.

1.1 Environmental Testing/Methodology

Collected paint samples were conducted in accordance with Practice E 1729.

Collected dust samples were conducted in accordance with Practice E 1728.

Collected soil samples were conducted in accordance with Practice E 1727.

Note Appendix B.

1.1.1 Painted Surfaces

All interior and exterior surfaces were in extremely poor condition with excessive peeling of paint. All windows were in extremely poor condition with excessive peeling of paint.

MTNF INSPECTOR JOHN CABLE

LEAD PAINT INSPECTION CERT# 120209-300003721

DATE 3/20/2015

BUILDING

RESIDENTIAL STRUCTURE, POTOSI, MO

SAMPLE LOCATION MATERIAL RESULTS

2 Living room window trough PAINT CHIPS 11%

4 Kitchen window trough PAINT CHIPS 0.56%

6 BEDRM W SILL PAINT CHIPS 3.1%

8 BEDRM window trough PAINT CHIPS 1.2%

12 Living Room window Paint chips 1.6% weight

13 Garage exterior Paint Chips 19 % weight

14 Living Rm window Sill Paint Chips 0.21% weight

15 Bedroom Window Paint Chips 7.2% weight

16 Bedroom Window Paint Chips 0.076% weight

17 BASEMENT WALL CHIPS 0.34 % weight

Risk Assessment clearance standards

DUST

SILLS 250 ug/FT2 TROUGHS 400ug/FT2 FLOORS 40 ug/FT2

SOIL

PLAY AREAS 400 ug/gram ALL OTHER 1200 ug/gram

PAINT 0.5% BY WEIGHT

evalade

1.1.2 Dust

All dust wipe samples were obtained from hard cleanable surfaces.

MTNF INSPECTOR JOHN CABLE

LEAD PAINT INSPECTION CERT# 120209-300003721

DATE 3/20/2015

BUILDING

RESIDENTIAL STRUCTURE, POTOSI, MO

SAMPLE LOCATION MATERIAL RESULTS

1 LIVING RM W-SILL DUST WIPE 850ug/ft2

3 KITCHEN W SILL DUST WIPE 31ug/ft2

5 BEDRM W SILL DUST WIPE 140 ug/ft2

7 BEDRM W SILL DUST WIPE 8700 ug/ft2

9 KITCHEN FLOOR DUST WIPE 36 ug/ft2

10 HALL FLOOR DUST WIPE 33ug/ft2

11 BASEMENT FLOOR DUST WIPE 820 ug/ft2

18 GARAGE FLOOR DUST WIPE 5500 ug/ft2

Risk Assessment clearance standards

DUST

SILLS 250 ug/FT2 TROUGHS 400ug/FT2 FLOORS 40 ug/FT2

SOIL

PLAY AREAS 400 ug/gram ALL OTHER 1200 ug/gram

PAINT 0.5% BY WEIGHT

1.1.3 Soil

A ten (10) Aliquot sample was obtained from bare-patchy grass covered soil.

MTNF INSPECTOR JOHN CABLE

LEAD PAINT INSPECTION CERT# 120209-300003721

DATE 3/20/2015

BUILDING

RESIDENTIAL STRUCTURE, POTOSI, MO

SAMPLE LOCATION MATERIAL RESULTS

SOIL EXTERIOR 10 ALIQUOTE SOIL 47 ug/gram

SOIL

PLAY AREAS 400 ug/gram ALL OTHER 1200 ug/gram

PAINT 0.5% BY WEIGHT

Conclusions

Three (3) window sill dust wipe sample exceeded HUD Standards (250 µg/ft2).

ALL (4) Collected floor dust wipe sample exceeded HUD Standards (40 µg/ft2).

No Soil sample exceeded HUD Standards 400 ug/gr or 1,2000 micrograms/gram

Seven (7) Paint Chip Samples exceed HUD standards (0.5% by weight).

evalade

2.0 SCOPE OF WORK

On March 20th 2015 Triangle Environmental Science and Engineering Inc, was contacted by Janet Fraley to conduct a Lead Risk Assessment on the subject property known as the Mark Twain National Forest, Ranger Station, Roby, MO. Two (2) structures were inspected and assessed on the subject site. The structures inspected are:

Ranger Station and Garage

The Lead Identification and Risk Assessment was conducted under the guidance of Missouri Revised Statute Chapter 701, State Standards, Section 701.304, ASTM E 2115 -06 “Standard Guide for Conducting Lead Hazard Assessments of Dwellings and of other Child-Occupied Facilities”, and the United States Department of Housing and Urban Development, 24 CFR Subtitle A, § 35.1320 Lead-based paint inspections and risk assessments.

The visual inspection revealed all exterior windows and trim to be in poor condition with excessive peeling of paint. Exterior walls of the structures inspected are wood, in poor condition, with excessive peeling of paint. Dust wipe samples were analyzed for lead concentrations/ft2. All dust wipe samples were collected from hard, cleanable surfaces, when possible. Soil and Paint chip samples were analyzed for total lead content.

Collected soil samples were conducted in accordance with E 1727, Practice for Field Collection of Soil Samples for Lead Determination by Atomic Spectrometry Techniques.

Dust samples were conducted in accordance with E 1728, Practice for Field Collection of Settled Dust Samples Using Wipe Sampling Methods for Lead Determination by Atomic Spectrometry Techniques.

Paint samples were conducted in accordance with E 1729, Practice for Field Collection of Dried Paint Samples for Lead Determination by Atomic Spectrometry Techniques.

3.0 SUBJECT PROPERTY INFORMATION

Mark Twain National Forest Roby Ranger Station and Garage, Roby MO

CONTACT PERSON:

Janet Fraley Mark Twain National Forest Service 401 Fairgrounds Road Rolla, MO 65401 573-364-4621 evalade

4.0 LEAD RISK ASSESSMENT

Developed under the protocols of the United States Department of Housing and Urban Development, §

35.1320 24 CFR Subtitle A, Subpart R Lead-based paint inspections and risk assessments (Source 64 FR 50218, Sept. 15, 1999).

4.1 Painted Surfaces

Collected paint chip samples shall not exceeded Federal Standards (0.5. % by weight).

4.2 Dust

The dust level hazard shall be a dust-lead level equal or greater than the applicable loading (area of concentration), based upon wipe samples, in the following (U.S. Department of Housing and Urban Development Interim Dust Lead Standards) table:

INTERIM DUST LEAD STANDARDS

EVALUATION METHOD SURFACE/FLOORS INTERIOR WINDOW SILLS

µg/ft2 mg/m2 µg/ft2 mg/m2

LEAD HAZARD SCREEN……… 25 0.27 125 1.4

RISK ASSESSMENT……………. 40 0.43 250 2.7

REEVALUATION………………. 40 0.43 250 2.7

CLEARANCE…………………… 40 0.43 250 2.7

Clearance for window troughs……………400 µg/ft2

4.3 Soil

Soil Lead Hazard for play areas frequented by children less than six years of age shall be bare soil with lead equal to or exceeding 400 micrograms per gram. (PPM)

For other areas, soil-lead hazards shall be bare soil that totals more than 9 square feet (0.8 square meters) per property with lead equal to or exceeding 1200 microgram per gram. (PPM) evalade

5.0 ANALYTICAL DATA

MTNF INSPECTOR JOHN CABLE

LEAD PAINT INSPECTION CERT# 120209-300003721

DATE 3/20/2015

BUILDING

RESIDENTIAL STRUCTURE, POTOSI, MO

SAMPLE LOCATION MATERIAL RESULTS

1 LIVING RM W-SILL DUST WIPE 850ug/ft2

2 Living room window trough PAINT CHIPS 11%

3 KITCHEN W SILL DUST WIPE 31ug/ft2

4 Kitchen window trough PAINT CHIPS 0.56%

5 BEDRM W SILL DUST WIPE 140 ug/ft2

6 BEDRM W SILL PAINT CHIPS 3.1%

7 BEDRM W SILL DUST WIPE 8700 ug/ft2

8 BEDRM window trough PAINT CHIPS 1.2%

9 KITCHEN FLOOR DUST WIPE 36 ug/ft2

10 HALL FLOOR DUST WIPE 33ug/ft2

11 BASEMENT FLOOR DUST WIPE 820 ug/ft2

12 Living Room window Paint chips 1.6% weight

13 Garage exterior Paint Chips 19 % weight

14 Living Rm window Sill Paint Chips 0.21% weight

15 Bedroom Window Paint Chips 7.2% weight

16 Bedroom Window Paint Chips 0.076% weight

17 BASEMENT WALL CHIPS 0.34 % weight

SOIL

GARAGE FLOOR

EXTERIOR 10 ALIQUOTE

DUST WIPE

SOIL

5500 ug/ft2 47 ug/gram

Risk Assessment clearance standards

DUST

SILLS 250 ug/FT2 TROUGHS 400ug/FT2 FLOORS 40 ug/FT2

SOIL

PLAY AREAS 400 ug/gram ALL OTHER 1200 ug/gram

PAINT 0.5% BY WEIGHT

Conclusions-

Three (3) window sill dust wipe sample exceeded HUD Standards (250 µg/ft2).

ALL (4) Collected floor dust wipe sample exceeded HUD Standards (40 µg/ft2).

No Soil sample exceeded HUD Standards 400 ug/gr or 1,2000 micrograms/gram

Seven (7) Paint Chip Samples exceed HUD standards (0.5% by weight).

evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

6.0 INTERIM OPTIONS

Wet clean all contaminated surfaces. Workers should wear disposable coveralls, shoes, hair covering, goggles, and a respirator approved by NIOSH (the National Institute of Occupational Safety and Health).

Approved respirators will have an approval number on them, (i.e., TC-21C-xxx). Only HEPA (High Efficiency Particulate Air) respirators will filter lead dust and fumes. Simple paper or fabric dust masks will NOT protect a worker from lead dust.

7.0 ABATEMENT OPTIONS

Wet clean all contaminated surfaces thoroughly. Workers should wear disposable coveralls, shoes, hair covering, goggles, and a respirator approved by NIOSH (the National Institute of Occupational Safety and Health). Approved respirators will have an approval number on them, (i.e., TC- 21C-xxx). Only HEPA (High Efficiency Particulate Air) respirators will filter lead dust and fumes.

Simple paper or fabric dust masks will NOT protect a worker from lead dust.

Encapsulate all exterior surfaces. These materials are applied over lead-based paint to seal the paint to a surface and prevent the release of paint chips or dust. The material may be either a liquid or an adhesive. Encapsulation provides a barrier between the paint and the environment.

Enclosure of all lead painted components.

Removal of paint by a lead abatement professional.

Complete removal of exterior lead painted component (windows and trim).

8.0 QUALIFICATIONS

John W Cable is a Missouri Department of Health and Senior Services licensed Lead Paint Inspector and a licensed Risk Assessor (Appendix A).

9.0 LIMITATIONS

This LEAD hazard inspection and risk assessment was conducted to evaluate potential lead contaminated hazards. It is based on a visual examination, inspections of records, collected samples, analytical results, and discussions with various persons, agencies, and businesses, all of which were used to develop the basis of our conclusions. Subsequent variations, while not likely, may exist and if found will require re-evaluation.

This report describes the lead hazards identified at the time the inspection was performed. The locations, types of severity of lead hazards can change over time as a result of property improvements or deterioration, significant changes in property us or other factors.

Although it is not possible to guarantee this Lead Hazard Inspection or even a more extensive diagnostic evaluation will in every case identify all possible sources of contamination, we believe the process described represents a reasonable and responsible investigation and is consistent with good commercial and engineering practices. This report should permit a high level of understanding of the current lead risk hazard condition of the subject tract and the surrounding property. The report was prepared for the exclusive use of our client.

evalade Typewritten Text evalade Typewritten Text evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

APPENDIX A

Qualifications: Missouri Department of Health and Senior Services, Risk Assessor License evalade

Qualifications:

University of Missouri –Rolla Bachelors of Science (Cum laude) Geological Engineering Masters’ of Science (Chancellor’s Fellow) Geological Engineering

Missouri Department of Natural Resources, Air Quality Control, Certified Asbestos Building Inspector Missouri Department of Health and Senior Services Certified Lead Paint Inspector Missouri Department of Health and Senior Services Certified Lead Risk Assessor Missouri Department of Natural Resources Certified DS-I Water Distribution Manager Missouri Department of Natural Resources Certified DS-II Water Distribution Manager Missouri Department of Natural Resources Certified D Waste Water Manager Missouri Department of Natural Resources Certified Well Installer State Of Missouri Professional Registered Geologist STS Certified Mold Remediation Specialist

Missouri University of Science and Technology Former Adjunct Instructor: Environmental Engineering Adjunct Instructor: Geological Engineering Adjunct Instructor: Geology

References/clientele :

Dr Addie Oslon, DVM, Navarre FL Intercounty Electric, Licking, MO National Hospitality, Fargo ND U.S. Foods, Salem, MO Rolla Municipal Utilities, Rolla, MO St Maries Medical Clinic, Jefferson City Puro Clean, Sullivan Puro Clean, Festus Serv Pro, St Charles Phelps County Bank, Rolla Bank of Crocker, Waynesville Bank of Crocker, Richland First Community National Bank, Rolla Rolla Public School District Waynesville Public School District Dixon Public School District Salem R-80 School District Northwood R-IV School District, Salem City of St James, St James First Community Credit Union, Chesterfield City of Eldon, Eldon City of Vienna, Vienna, MO Newburg School District, Newburg Metro Business College, Rolla, Missouri Ozark Community Action, Richland Phelps County Regional Medical Corporation Mark Twain National Forest Spartan Services, St Robert, MO Meramec Regional Planning Commission Rolla Regional Economic Commission Richland School District Strain Japan School District, Cuba Farmers Insurance Heritage Bank of Ozarks, Camdenton State Farm Insurance Fidelity Communications Essayons Construction, Waynesville Staybridge Inn& Suites, Columbia Sneider Engineering, Columbia MFA Break-time, Columbia United Country, Salem Bank of Sullivan, Sullivan U.S.G.S. Rolla Spray Services, Washington City of Bourbon, Bourbon Investment Realty, Rolla Septagon Construction National Parks Service Comfort Inn, St Robert

JOHN W. CABLE

President/owner Triangle Environmental Science and Engineering Inc Rolla, MO 573-308-0140 evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

APPENDIX B

Lead Inspection Records, Chain of Custody and Analytical Results evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

OrderID: 391502330 evalade Typewritten Text ROBY DWELLING AND SMALL GARAGE DEMOLITION/REMOVAL Attachment "B"

OrderID: 391502328 evalade

OrderID: 391502328 evalade

ConcentrationAnalyzed RDL LeadClient SampleDescription Collected

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

3029 S. Jefferson, Saint Louis, MO 63118 Phone/Fax: (314) 577-0150 / (314) 776-3313 http://www.EMSL.com saintlouislab@emsl.com

Attn: John Cable Triangle Environmental Science P.O. Box 1026 Rolla, MO 65401

Received: 03/24/15 10:20 AM

MTNF-Roby

Fax:

Phone: (573) 308-0140

Project:

Collected:

391502328 CustomerID: TRIA77 CustomerPO: 32315 ProjectID:

EMSL Order:

11 % wt3/25/2015 391502328-0001

0.50Roby- 2 % wt

0.56 % wt3/25/2015 391502328-0002

0.050Roby- 4 % wt

3.1 % wt3/25/2015 391502328-0003

0.10Roby- 6 % wt

1.2 % wt3/25/2015 391502328-0004

0.050Roby- 8 % wt

1.6 % wt3/25/2015 391502328-0005

0.050Roby- 12 % wt

19 % wt3/25/2015 391502328-0006

1.0Roby- 13 % wt

0.21 % wt3/25/2015 391502328-0007

0.010Roby- 14 % wt

7.2 % wt3/25/2015 391502328-0008

0.50Roby- 15 % wt

0.076 % wt3/25/2015 391502328-0009

0.010Roby- 16 % wt

Page 1 of 1Test Report PB w/RDL-7.32.3 Printed: 3/25/2015 3:01:31 PM

Jeff Siria, Laboratory Manager or other approved signatory

*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements established by the AIHA-LAP, unless specifically indicated otherwise.

Samples analyzed by EMSL Analytical, Inc. Saint Louis, MO AIHA-LAP, LLC--ELLAP Accredited #102636

Initial report from 03/25/2015 15:01:31 http://www.EMSL.com mailto:saintlouislab@emsl.com evalade Typewritten Text evalade

OrderID: 391502329 evalade

OrderID: 391502329 evalade

ConcentrationAnalyzed Area Sampled RDL LeadClient SampleDescription Collected

Test Report: Lead in Dust by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

3029 S. Jefferson, Saint Louis, MO 63118 Phone/Fax: (314) 577-0150 / (314) 776-3313 http://www.EMSL.com saintlouislab@emsl.com

Attn: John Cable Triangle Environmental Science P.O. Box 1026 Rolla, MO 65401

Received: 03/24/15 10:20 AM

MTNF-Roby

Fax:

Phone: (573) 308-0140

Project:

Collected:

391502329 CustomerID: TRIA77 CustomerPO: 3-23-15 ProjectID:

EMSL Order:

48 850 µg/ft²in²3/30/2015 391502329-0001

30Roby- 1 µg/ft²

48 31 µg/ft²in²3/30/2015 391502329-0002

30Roby- 3 µg/ft²

48 140 µg/ft²in²3/30/2015 391502329-0003

30Roby- 5 µg/ft²

48 8700 µg/ft²in²3/30/2015 391502329-0004

300Roby- 7 µg/ft²

144 36 µg/ft²in²3/30/2015 391502329-0005

10Roby- 9 µg/ft²

144 33 µg/ft²in²3/30/2015 391502329-0006

10Roby- 10 µg/ft²

144 820 µg/ft²in²3/30/2015 391502329-0007

50Roby- 11 µg/ft²

144 5500 µg/ft²in²3/30/2015 391502329-0008

200Roby- 18 µg/ft²

0 <10 µg/wipein²3/30/2015 391502329-0009

10Roby- 19 µg/wipe

Page 1 of 1Test Report PB w/RDL-7.32.3 Printed: 3/30/2015 11:04:22 AM

Jeff Siria, Laboratory Manager or other approved signatory

*Analysis following Lead in Dust by EMSL SOP/ Determination of Environmental Lead by FLAA. Reporting limit is 10 ug/wipe. ug/wipe = ug/ft2 x area sampled in ft2. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities (such as volume sampled) or analytical method limitations. Samples received in good condition unless otherwise noted. The lab is not responsible for data reported in µg/ft² which is dependant on the area provided by non-lab personnel. The test results contained within this report meet the requirements of NELAC unless otherwise noted. "<" (less than) results signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements established by the AIHA-LAP, unless specifically indicated otherwise Samples analyzed by EMSL Analytical, Inc. Saint Louis, MO AIHA-LAP, LLC--ELLAP Accredited #102636

Initial report from 03/30/2015 11:04:22 http://www.EMSL.com mailto:saintlouislab@emsl.com evalade Typewritten Text evalade Typewritten Text evalade

OrderID: 391502330 evalade Typewritten Text evalade

ConcentrationAnalyzed RDL LeadClient SampleDescription Collected

Test Report: Lead in Soils by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

3029 S. Jefferson, Saint Louis, MO 63118 Phone/Fax: (314) 577-0150 / (314) 776-3313 http://www.EMSL.com saintlouislab@emsl.com

Attn: John Cable Triangle Environmental Science P.O. Box 1026 Rolla, MO 65401

Received: 03/24/15 10:20 AM

MTNF-Roby

Fax:

Phone: (573) 308-0140

Project:

Collected:

391502330 CustomerID: TRIA77 CustomerPO: 32215 ProjectID:

EMSL Order:

47 mg/Kg3/27/2015 391502330-0001

40Soil mg/Kg

Page 1 of 1Test Report PB w/RDL-7.32.3 Printed: 3/27/2015 2:13:27 PM

Jeff Siria, Laboratory Manager or other approved signatory

*Analysis following Lead in Soil/Solids by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 40 mg/kg based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. Results reported based on dry weight. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements established by the AIHA-LAP, unless specifically indicated otherwise Samples analyzed by EMSL Analytical, Inc. Saint Louis, MO AIHA-LAP, LLC--ELLAP Accredited #102636

Initial report from 03/27/2015 14:13:27 http://www.EMSL.com mailto:saintlouislab@emsl.com evalade

File details come from the government source that posted it. Updated .