Item Description Qty

Network Equipment

Firewall

Network Firewall with the following characteristics: minimum of 4 installed SFP/SFP+ (1/10Gbps) and minimum 12 installed RJ45 (1Gbps) ports. Must support expansion modules to add an additional 16 or more SFP/SFP+ (1/10Gbps) and an additional 8 or more QSFP+ ports. Must have dual redundant and hot-pluggable power supplies. Must include all hardware to support mounting in 19in server rack and 2 post telecomm rack.

Core Switch

Core Switches with the following characteristics: minimum of 24 installed SFP/SFP+ (1/10Gbps) and minimum 4 installed QSFP+ (40Gbps) ports. Must support expansion modules to add an additional 16 or more SFP/SFP+ (1/10Gbps) and an additional 8 or more QSFP+ ports. Must have dual redundant and hot-pluggable power supplies. Must include all hardware to support mounting in 19in server rack and 2 post telecomm rack.

Distribution Switch

Distribution Switches with the following characteristics: minimum of 48 RJ45 Connectors supporting 1Gbps Ethernet (1000baseT) with support for 48 Ports supplying Power Over Ethernet Plus (PoE+) at 30W per port. Minimum of 4 installed SFP/SFP+ (1/10Gbps) and minimum 2 installed QSFP+ (40Gbps) ports.

Must have dual redundant and hot-pluggable power supplies. Must include all hardware to support mounting in 19in server rack and 2 post telecomm rack.

10Gbps Optics SFP+ Optics providing 10Gbps over a single pair of Single Mode Fiber (SMF)

ARS Corvallis, OR Phase 1 - February 14, 2017

10Gbps DAC 10Gbps Direct Attached Cable (Twinax) 7

Wireless

Cisco3702i Cisco Wireless Access Point 18

CiscoWAPLicense License for CiscoWAP 18

OPTIONAL Add-on UPS Hardware

UPS Node UPS to support network nodes - must provide a minimum of 3000VA/2400W and a minimum of 3 minutes run time at full load

UPS Major UPS to support network core points - must provide a minimum of

6000VA/4500W