Amend_3_Q A_II_-_S-16-46_Demo_15_Bldgs_BARC.pdf

PDF 21 KB Posted

Attached to
Demolition 15 Buildings BARC
Solicitation number
AG-32SC-S-16-0046
Issued by

About this file

Questions Answers II 7SEP16. Second set of Q A.

View the file

Other files

File Type Posted
Sol_AG-32SC-S-16-0046_Amd_000003.pdf PDF
Sign_In_sheet_-_Thur_-_Demo_15_Bldgs_BARC.pdf PDF
Sol_AG-32SC-S-16-0046_Amd_000002.pdf PDF
Sign_In_sheet_-_Wed_-_Demo_15_Bldgs.pdf PDF
Amend_2_Q A_-_S-16-46_Demo_15_Bldgs_BARC.pdf PDF
Sol_AG-32SC-S-16-0046_Amd_000001.pdf PDF
Past_Performance_Project_Sheet_-_Demo_15_Bldgs__BARC.docx DOCX document
of0306.pdf PDF
Wage_Decision_15-4281_Rev_3_-_Demo_15_Bldgs_BARC.pdf PDF
AD-1197fill.pdf PDF
Person_Model_PII_Sheet_-_Revised_April_2015.pdf PDF
Specification_02_08_10_Asbestos.doc DOC document
Specification_01_34_00_Submittals.doc DOC document
Specification_01_74_19_Demolition_Waste_management.doc DOC document
Specification__31_20_11_Earthwork.doc DOC document
Specification_02_84_16_Lamps_Containing_PCB_and_Mercury.doc DOC document
Specification_02_41_00_Demolition.doc DOC document
Specification_02_09_00_Disturbance_of_Lead.doc DOC document
Specification_01_01_00_General_Conditions.doc DOC document
Building_470A_Reference_Drawing_1963_Study_for_Drainage.pdf PDF
Building_470AA_to_470JJ_Reference_Drawings_-_Combined.pdf PDF
Building_470A_Reference_Drawing_1963_Drainage.pdf PDF
Building_470A_Reference_Drawing_1967_Greenhouse_Construction.PDF PDF
Building_470A_Reference_Drawing_1962_Blower_Coolers_installation.pdf PDF
Building_470A_Reference_Drawing_1979_Boiler_Installation.pdf PDF
Building_470A_Reference_Drawing_1978_Greenhouse_Modifications.pdf PDF
Building_470A_Reference_Drawing_1967_Greenhouse_for_Alfalfa_Invest.pdf PDF
Building_255A_Reference_Drawing_Greenhouse_Tables.PDF PDF
Building_255A_Reference_Drawing_1962_Preliminary_for_Estimate_only.pdf PDF
Building_288A_Reference_Drawings_Combined.pdf PDF
Building_255A_Reference_Drawing_1998_Drainage_Modifications.pdf PDF
Building_255A_Reference_Drawing_1962_Grading_Plan.pdf PDF
Building_255A_Reference_Drawing_Site_Plan.pdf PDF
Building_255A_Reference_Drawing_1962_Lighting_ _Plumbing.pdf PDF
Building_255A_Reference_Drawing_Alterations.pdf PDF
Building_255A_Reference_Drawing_1962_Experimental_Poultry_Breeder.pdf PDF
Building_177B_Reference_Drawing_1963_Construction_of_Concrete_Slab.pdf PDF
Building_177B_Reference_Drawing_Site_Plan.pdf PDF
Building_009_Reference_Drawing_1941_Original_Construction.pdf PDF
Building_177B_Reference_Drawing_1966_Experimental_Poultry_Breeding_House.pdf PDF
Building_177B_Reference_Drawing_1984_Replace_HVAC_System.pdf PDF
Sol_AG-32SC-S-16-0046_Demo_15_Bldgs_BARC.pdf PDF
Building_009_Reference_Drawing_Site_Plan.pdf PDF
Building_177B_Reference_Drawing_1967_Electron_Microscope_Lab-Meeting_Room.pdf PDF
Building_177B_Reference_Drawing_1987_HVAC_Replacement_-_West_End.pdf PDF
BARC_Site_Vist_MAP_07-25-16.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

United States Department of Agriculture

Research, Education, and Economics Agricultural Research Service

Eastern Business Service Center, Acquisition Branch 1815 North University Street

Peoria, IL 61604-3902 USDA is an Equal Opportunity Provider and Employer

AG-32SC-S-16-0046 Demo 15 Bldgs, BARC, Beltsville, MD Amendment 003 – Questions & Answers II – 7SEP16

7. Due to the spread out nature of this project, can the recycle 60% and the landfill diversion spec be disregarded? Most worthwhile items have already been removed.

A. No.

8. Who is responsible for the demo permit and SEC plan/implementation?

A. The contractor.

9. Is there a suitable borrow area on site as alluded to in the spec?

A. No, Specification 31 20-11.3.2.D indicates “D. Borrow Material: Borrow material shall be from a site off of Government property.”

10. What about the additional HazMats not listed/quantified in the reports (mostly chemicals)?

A. Make your proposal based on the quantities described in the contract documents.

11. The spec lists who is responsible for marking the utilities but who is cutting and capping them (quantity??)?

A. Specification 02 41 00.3.1.C indicates “C. Remove existing utilities as indicated or uncovered by work and terminate in a manner conforming to the nationally recognized code covering the specific utility and approved by the Contracting Officer.”

12. Does the bridge near the antenna array have a weight limit?

A. Specification 01010.1.7.C indicates “C. The Contractor shall, under regulations prescribed by the Contracting Officer, use only established roadways, or use temporary roadways constructed by the Contractor when and as authorized by the Contracting Officer.” If the contractor desires to use unusually heavy equipment, temporary roads may be considered for approval by the Contracting Officer.”

13. When will the 180 days start? After the proper paperwork/environmental? For example there was some question as to whether or not you have the required generator EPA ID #.

A. Upon receipt of the Notice to Proceed.

14. Will the sites be released all at once?

A. Yes.

END of Questions & Answers

File details come from the government source that posted it. Updated .