R6-FS-6300-53 (5/89)
USDA FOREST SERVICE
PACIFIC NORTHWEST REGION
FIRE PROTECTION AND SUPPRESSION
Additional Fire Precautionary Measure 1 - Tank Truck
11.
The Contractor shall provide a tank truck or trailer, containing not less than 300 gallons of water, during yarding, loading, land clearing, right-of-way clearing and mechanical treatment of slash. A tank truck or trailer will not be required if powersaw falling and bucking is the only operation. Such tank truck or trailer shall be maintained in a serviceable condition and located within 10 minutes, round trip, from each project area during fire period and closed seasonFire Period and Closed Season.
The tank truck or trailer shall be equipped with a pump capable of discharging 20 gallons of water per minute, using a 1/4 inch nozzle tip, through a 50 foot length of rubber line hose. In addition, 500 feet of serviceable fabric jacket rubber lined hose of not less than 1 inch outside diameter, fitted with a nozzle capable of discharging a straight stream of 1/4 inch diameter and a spray pattern shall be immediately available for use. The tank, pump and at least 250 feet of hose and nozzle shall be connected and ready for use at all times.
If a trailer is used, it shall be equipped with a hitch to facilitate prompt movement. A serviceable tow vehicle shall be immediately available for attachment to the trailer and must meet the time requirements stated above. Such truck or trailer shall be equipped to operate for a minimum of 8 hours. Tank truck or trailer shall be available from the start of work to the end of the Fire Watch / Fire Security service.
Other files
| File | Type | Posted |
|---|---|---|
| WORK DESCRIPTION LIST Rd 1306-365.docx | DOCX document | |
| Vicinity Map Sheet 1 of 5.pdf | ||
| RoadBerm Sheet 4 of 5.pdf | ||
| experience_questionaire.doc | DOC document | |
| Stream Stabilazation Sheet 5 of 5.pdf | ||
| WaterBar Sheet 3 of 5.pdf | ||
| Wildcat CONSTRUCTION_RFQ.doc | DOC document | |
| r6-fs-6300-54.rtf | RTF text file | |
| GENERAL WAGE DECISION.docx | DOCX document | |
| fire_clauses_r6-fs-6300-52.doc | DOC document | |
| Vicinity Map Sheet 2 of 5.pdf | ||
| WORK DESCRIPTION LIST Rd 1362-378.docx | DOCX document | |
| Technical Specs.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .