Advantor Upgrade for Program Office
Access Control Refresh
· Upgrade SF/Xi to SF/Xi6.2 with badging, including new report printer, badging printer, switch and
· firewall.
· Upgrade panels 5001, 5002 & 5003 to IG2 FIPS panels.
· Remove Main Entry 140 from 5002 and cap with plate.
· Remove ECC 1 Rm 131 from 5003 and cap with plate.
· Replace all existing card readers (now Prox/Pro) with HID RPK40 readers.
IDS Refresh
· Upgrade IDS panels in Program Office area with IG2 FIPS panels.
· Provide and install ITK keypads to replace TSK Keypads (2 total).
· Replace all motion sensors with AP669 sensors.
· Replace perimeter BMS with HSS
· Perform turnkey installation of all components, including all necessary conduit and wiring.
· Wire above ceilings will be installed on J-hooks or in cable trays.
· Wire below ceilings will be in EMT Conduit.
· Conduct Contractor Verification Testing and commission system into service.
· Provide software instruction on SF/Xi6 system, including enrollment, schedule set up and system administration.
· Provide as-built drawings of final configuration, including device placement and wire paths.
The Government will provide the following collateral support:
· Provide storage and staging space for project materials.
· Provide access to work areas in conformance with pre-arranged installation schedule.
· Provide AutoCAD floor plans as necessary for creation of as-built drawing.
· Provide access to 120VAC power for all components requiring AC Power (Advantor to perform power connections.)
· *All electrical work to be performed by a licensed electrician