Date Printed: Nov 18, 2024 Page: 1 FORM ID: WV-PRC-CRFQ-002 2020/05
Department of Administration Purchasing Division 2019 Washington Street East Post Office Box 50130 Charleston, WV 25305-0130
State of West Virginia Centralized Request for Quote
Construction
Proc Folder: 1535631 Reason for Modification:
Doc Description: Hawks Nest State Park Tramway Upper & Lower Terminal Addendum #1 issued to publish pre-bid sign in sheet, agency responses to vendor submitted questions,..... See Page 2 for complete infoProc Type: Central Purchase Order
Date Issued Solicitation Closes Solicitation No Version
2024-11-18 2024-12-10 13:30 CRFQ 0310 DNR2500000006 2
BID RECEIVING LOCATION
BID CLERK
DEPARTMENT OF ADMINISTRATION
PURCHASING DIVISION
2019 WASHINGTON ST E
CHARLESTON WV 25305
US
VENDOR
Vendor Customer Code:
Vendor Name :
Address :
Street :
City :
State : Country : Zip :
Principal Contact :
Vendor Contact Phone: Extension:
FOR INFORMATION CONTACT THE BUYER
Joseph E Hager III
(304) 558-2306 joseph.e.hageriii@wv.gov
Vendor Signature X FEIN# DATE
All offers subject to all terms and conditions contained in this solicitation
Date Printed: Nov 18, 2024 Page: 2 FORM ID: WV-PRC-CRFQ-002 2020/05
Reason for Modification:
Addendum #1 issued to publish pre-bid sign in sheet, agency responses to vendor submitted questions, Revised Drawings, Geotechnical Report, and to extend the bid close date until 12/10/2024 @ 1:30 PM ET.
ADDITIONAL INFORMATION
The West Virginia Purchasing Division is soliciting bids on behalf of The West Virginia Division of Natural Resources to establish a contract for the construction of the Tramway Terminals at Hawks Nest State Park per the attached specifications and terms and conditions.
INVOICE TO SHIP TO
DIVISION OF NATURAL
RESOURCES
DIVISION OF NATURAL
RESOURCES
PARKS & RECREATION-PEM
SECTION
HAWKS NEST STATE PARK
324 4TH AVE 49 HAWKS NEST PARK RD
SOUTH CHARLESTON WV ANSTED WV
US US
Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 1 Building and Facility Construction and
Maintenance Services
Comm Code Manufacturer Specification Model #
72000000
Extended Description:
Hawks Nest State Park New Tramway Upper and Lower Terminal Construction.
SCHEDULE OF EVENTS
Line Event Event Date
Revised 6/8/2012
SOLICITATION NUMBER: [Insert RFQ, RFP No.] Addendum Number: [Insert Number]
The purpose of this addendum is to modify the solicitation identified as [insert RFQ, RFP No.] (“Solicitation”) to reflect the change(s) identified and described below.
Applicable Addendum Category:
[ ] Modify bid opening date and time
[ ] Modify specifications of product or service being sought
[ ] Attachment of vendor questions and responses
[ ] Attachment of pre-bid sign-in sheet
[ ] Correction of error
[ ] Other
Description of Modification to Solicitation:
Additional Documentation: Documentation related to this Addendum (if any) has been included herewith as Attachment A and is specifically incorporated herein by reference.
Terms and Conditions:
1. All provisions of the Solicitation and other addenda not modified herein shall remain in full force and effect.
2. Vendor should acknowledge receipt of all addenda issued for this Solicitation by completing an Addendum Acknowledgment, a copy of which is included herewith.
Failure to acknowledge addenda may result in bid disqualification. The addendum acknowledgement should be submitted with the bid to expedite document processing.
Attachment A
W V
D N
R Br ad le y Le sl ie
4t h
Av e
So ut h C ha rle st on br ad .s
.le sl ie w v.
go v
RFI: Vendor Questions for CRFQ DNR 25*06 Hawks Nest Tram Upper & Lower Terminal
Q.1. Could you please provide the Geotechnical Report for the above-referenced project?
A. Will be provided in the addendum.
Q.2. What is the load at the pile?
A. Loads on the various piles vary.
Q.3. Can a Geotech Report be provided for both the upper and lower landing?
A. Will be provided in the addendum
Q.4. Could additional contour lines of the existing elevations and proposed finished elevations be provided? (See Sheet U-C101 & Sheet L-C101)
A. Finished grade is approximately the same as the existing condition with the rip rap rock being applied as per the detail.
Q.5. For life safety, will the river access road be closed to the public during the construction of the upper platform?
A. No, contractor is required to maintain a safe work site and provide temporary measures to prohibit public access to the work.
Q.6. If the river access road will not be closed to the public during the construction of the upper platform, what extra ordinary measures will need to be provided?
A. No, contractor is required to maintain a safe work site and provide temporary measures to prohibit public access to the work.
Q.7. Sheet: S000_Confirm the (3) three Pre-Installation Cores are to be drilled at a minimum of 10 feet in depth. Sheet U-S501 indicated the depth of the rock socketed drilled shafts to be 5 feet. Also, typically, the Pre-Installation Cores are located where a permanent core is scheduled to be installed to minimize costs to the End User. Confirm the Pre-Installation Cores can be installed at the designated location.
A. As per Structural Notes - “Rock Socket Drilled Shafts” Note 9 describes the requirements for Pre-installation Cores. Sheet U-S502 refers to depth of rock sockets for the drilled shaft. The Preinstallation cores will be drilled at a Shaft location as indicated.
Q.8. Are we to provide a per LF Unit of Measure to Add and/or Deduct Rock Socketed Drilled Shafts?
A. As per Structural “Rock Socket Drilled Shafts” Note 12, provide a unit cost per foot ($/LF) for addition/deduction of Rock Socketed Drilled Shafts.
Q.9. Where can I find on the Structural Plan Sheets how many Micro Piles to be installed at each of the Footers identified on Sheet L-S101, Footer Types F1, F2, F3, F4, F5, F6 & F7?
A. No micro-piles are utilized for the project. See addendum.
Q.10. Where can I find on the Structural Plan Sheets the designed depth of each Micro Pile to be installed at each of the Footers identified on Sheet L-S101, Footer Types F1, F2, F3, F4, F5, F6 & F7?
Q.11. Are we to provide a per LF Unit of Measure to Add and/or Micro Piles?
Q.12. What is Doppelmyar’s Substantial Completion date?
A. Currently it is April 28, 2025
Q.13. Will Doppelmyar have the concrete Masts installed prior to the anticipated start date of the upper & lower platforms? The RFQ identifies 120 days for substantial completion & 150 calendar days to be complete with the installation of both the upper & lower platforms. Even with both platforms being constructed simultaneously, the construction duration is not practical, due to the submittal process, cure times required for concrete foundations and piers prior to installing the structural steel, manufacturing the structural steel, galvanizing the structural steel, and erecting the structural steel. These tasks alone will take 150 calendar days. Requesting 150 days be extended to 270 days to avoid adding $500 a day for Liquidated Damages.
A. Contractor shall develop a construction sequence that allows for construction within the allotted timeframe.
Q.14. What is the Bid Hold period, 30, 45, 60 days?
A. Please see Section 13: Pricing, under the General Terms and Conditions of Solicitation Documents.
Q.15. What is the timeline for “AOE” responses for RFI’s during the construction phase? Typically, (7) seven days is allotted to address RFI’s to minimize construction schedule busts.
A. Architect will normally provide answers to RFI in a seven-day period. In rare occasions if the answer requires additional information the seven days may extend to 14 days.
Q.16. What is the timeline for “AOE” responses for Change Order Proposals? Typically, (7) seven days is allotted to address COP’s in order to minimize construction schedule busts.
A. Architect will normally provide answers to RFI in a seven-day period. In rare occasions if the answer requires additional information the seven days may extend to 14 days.
Q.17. What is the timeline for “AOE” to provide AIA Change Orders for processing through the State of WV & Auditors Office for encumbrance?
A. This varies depending on the complexity of the change order and workload of the various Agencies involved.
Q.18. On the WV Purchasing Division documents it states no change order work is to commence without a Change Order encumbered. Will additional calendar days be granted for the delay process due to waiting on encumbered Change Orders that may fall in the Sequence of Operations?
A. Change Orders should be anticipated and processed ahead of time to avoid needless delays.
Q.19. Is Hawks Nest State Park within City Limits & do B&O Taxes apply?
A. The upper station work is in Anstead and requires the payment of B&O taxes. The lower station is not.
Q.20. Shall the Builder’s Risk Insurance be for the Contract amount or for the Contract amount and the appraisal amount for the existing structures?
A. Contract amount.
Q.21. Will a temporary office trailer be required for Progress Meetings, or will a designated room be provided at the Facility?
A. Owner will provide a conference room for Architect/Owner/Contractor progress meetings.
Contractor to determine if he needs an onsite office trailer to meet their needs.
Q.22. Will the Contractor be permitted access for usages of power & water without reimbursement?
A. The contractor will be provided access to the power and water for the park for construction without reimbursement.
Q.23. There are several bridge crossings to reach the lower platform site. Confirm all existing bridges weight limits are adequate for transporting aggregates, concrete, steel onloaded tantum trucks.
A. The two upper bridges have been bi-passed by utilizing the trail as shown at the mandatory pre-bid meeting. The lower bridge is capable of meeting standard highway loads.
Q.24. Will WVDNR clear overhead hanging branches on the river access road prior to the lower platform work commencing?
A. Contractor is responsible for removing overhead branches as necessary for their work.
Q.25. Is this project set up for weekly or bi-weekly Progress Meetings? Specification 01310 Progress Meeting, Reporting states Progress Meeting are not used.
A. On-site progress meeting will be held monthly with the additional virtual meeting held bi-weekly if necessary, during the progress of the project.
Q.26. Could Doppelmayr Drawing No. 90012064NA0005101 be provided as per Sheet U-S504?
A. Doppelmayr mast reinforcement drawing No. 90012064NAD005101 is no longer applicable for this project. Contractor shall coordinate with Doppelmayr for current tram design information: see Special Note 1A, Sheet S000.
Q.27. Would Doppelmayr provide the Platform Contractor with the coordinate sheets used for installing the concrete Masts?
A. Contractor shall coordinate with Doppelmayr for current tram design information: see Special Note 1A, Sheet S000.
Q.28. Would it be a conflict of interest for the Platform Contractor to hire as a Third-Party Consultant the Engineer/Surveying Company Alpha hired for the layout during design phase? This Surveyor would already have the information required to layout the platforms and would save some time.
A. The Surveyor for the layout was hired by Doppelmayr and this would not be considered a conflict.
Q.29. Note 2 States; Allow treated lumber sufficient time (6-8 months) before staining. (6) Six months is 180 days, (8) months is 240 days. RFQ States; Contract duration is 150 calendar days. The timeline doesn’t work, please advise.
A. We would anticipate that the contractor would purchase properly cured lumber and that this should not impact your timeline.
Q.30. Shall (4) four sides of the timber platform decking require Section 099300 Solid Color Staining or just the side exposed to the foot traffic?
A. All 4 sides.
Q.31. At the Upper Landing, will seismic monitoring be required at the existing structures near the project site, rock out cropping’s and rock high wall for safety concerns, liabilities and record keeping?
A. Contractor is responsible for maintaining the integrity of the existing structures and shall take any measures they believe appropriate including but not limited to a pre-work survey and/or monitoring during construction.
Q.32. Confirm all Structural Steel at canopies shall be delivered shop-primed and not galvanized. (Sheet U-S104 & Sheet L-S104 Note 3)
A. Confirmed. Canopy steel shall not be hot-dip galvanized.
Q.33. Confirm Pad-Mounted Transformer identified on the Plan Sheets and provided by AEP is being paid through a Work Order by WVDNR.
A. Yes
Q.34. Is this project subject to the Prompt Payment Act?
A. No.
Q.35. Please confirm the following activities would be omitted from the Scope of Work should the Alternate deduct be accepted.
A. Sheet U-S104 Upper Station-Canopy Framing Plans; would be omitted.
B. Sheet U-S502 Upper Station-Column Schedule; A-1.0, A-2.0, A-3.0, B-1.0 & B-3.0 would be resized.
C. Sheet A000 Architectural Material Notes; Specification 047300-Manufactured Stone would be omitted.
D. Sheet A000 Architectural Material Notes; Specification 047300-Manufactured Stone Column
Cap would be omitted.
E. Sheet A000 Architectural Material Notes; Specification Section 053100-Roof Deck would be omitted.
F. Sheet A000 Architectural Material Notes; Specification Section 075323 – Ethylene-Propylene-
Diene-Monomer (EPDM) Roofing would be omitted.
G. Sheet A000 Architectural Material Notes; Specification Section Miscellaneous Materials-
Sheet Metal Flashing, Gutters & Downspouts would be omitted.
H. Sheet U-A102 Upper Station-Canopy Reflected Ceiling & Roof Plan; would be omitted.
I. Sheet U-A201 Upper Station-Elevations; notes indicating Platform Canopy Beyond, Painted
Steel Column (Typ.), Manufactured Stone Column Cap (Typ.), Brick Column Wrap. Brick to match existing building in size & color. (Typ.), Aluminum Gutter & Downspout.
J. Sheet U-A202 Upper Station-Elevations; notes indicating Platform Canopy, Painted Steel
Column (Typ.), Manufactured Stone Column Cap (Typ.), Aluminum Gutter & Downspout.
K. Sheet U-A301 Upper Station-Platform Canopy Sections; would be omitted.
L. Sheet U-A501 Upper Station-Details; Detail 6/U-A501 would be omitted. Details for installing floor mounted fall protection would change.
M. Sheet U-E102 Upper Station-Tram Level Lighting Plan; Detail 2/U0E102 would be omitted along with Electrical Note 6.
N. Sheet L-S104 Lower Station-Canopy Framing Plans; would be omitted.
O. Sheet L-S301 Lower Station-Sections; references to Canopy Framing. Seeing roof framing plan would be omitted. References to HSS Columns (Typ.) would be omitted.
P. Sheet L-S302 Lower Station-Sections; references to Manufactured Stone Cap & Column Wrap.
(See Arch)
Q. Sheet L-A101 Lower Station-Tram Level Floor Plan; references to Manufactured Stone Cap &
Column Wrap drawn would be omitted, railing detail for fall protection would change.
R. Sheet L-A102 Lower Station-Canopy Roof Plan; would be omitted.
S. Sheet L-A111 Lower Station-Reflected Ceiling Plan; would be omitted.
T. Sheet L-A201 Lower Station-Elevations; notes indicating Platform Canopy Beyond, Painted
Steel Column (Typ.), Manufactured Stone Column Cap (Typ.), Brick Column Wrap (Typ.), EPDM, Aluminum Gutter & Downspout, Surface Mounted Directional Lighting (Typ.).
U. Sheet L-A202 Lower Station-Elevations; notes indicating Platform Canopy Beyond, Painted
Steel Column (Typ.), Manufactured Stone Column Cap (Typ.), Brick Column Wrap (Typ.), EPDM, Aluminum Gutter & Downspout, Surface Mounted Directional Lighting (Typ.).
V. Sheet L-A301 Lower Station-Sections; notes indicating Platform Canopy Beyond, Painted Steel
Column (Typ.), Manufactured Stone Column Cap (Typ.), Brick Column Wrap (Typ.), EPDM, Aluminum Gutter & Downspout, Surface Mounted Directional Lighting (Typ.).
W. Sheet L-A302 Lower Station-Stair Section & Column Wrap Detail; detail 2/L-A302 would be omitted.
X. Sheet L-E103 Lower Station-Tram Level Lighting Plan; detail 2/L-E103 and Note 4 would be omitted.
A. The items on the alternate are identified on the reissued plans dated 10/23/24.
Q. 36. Referring to Sheet U-A101; Is the concrete identified in the screenshot below between Column Line E-F the exposed foundation for the Mast?
A. This is the foundation for the mast.
Q.37. Referring to the Lower Landing Tram; there appears to be several large sycamore trees with low branches that could be encroaching the canopy. Should these trees be trimmed and removed to avoid possible future damage to the new structure?
A. The contractor is responsible for trimming any trees that may affect construction.
Q.38. Referring to Column Line 1.0, E & C; 25 feet high and 14 feet wide clearances will be required for the equipment to maneuver. There will not be enough room to install the rock socketed drilled shafts if the bull wheel canopy is installed by Doppelmayer. Could the canopy on the bull wheel be installed after the rocket socketed drilled shafts are installed?
A. Column lines 1 at E and C do not appear to conflict with the bull wheel or the canopy.
Given your dimensions and the location of the bull wheel you have 14 feet from the edge of the building to the bull wheel projection. These are fixed dimensions, and you should plan accordingly. It is likely the bull wheel will be installed at the time you are drilling the shafts.
Q.39. Referring to the existing access road at the upper landing for a crane; a few trees will need to be removed, and the road widened in a few areas. It is my understanding permission would be required from the Town of Anstead. Could confirmation be provided within subsequent addendum for the removal of the trees and widening of the access road?
A. The contractor is responsible for accessing the site as deemed appropriate and is responsible for the methods and means of construction. The upper station road is on DNR property and requires no approval from the Town of Anstead.
Q.40. Confirm no existing and/or new site utilities and/or existing foundations from building previously demolished are within the new footprint of the new lower platform, steps and ramps.
A. The main platform, EVAC and the ramps to the south and west of the platform are totally outside of the old building and foundations and should not encounter any buried foundations. The water line as shown on the site plan will be under the station and shall be protected. Foundations for the Generator and a portion of the ramps may encounter old debris from the existing building (Column line 6.0 and 6.2 from K2 to G)
Q.41. Referring to Sheet L-C101; the plans indicate cutting a section of the hillside for the relocation of gravel road. There appears to be a yard hydrant within the cut. Shall this yard hydrant be removed and/or shall the underground piping and hydrant be relocated?
A. Access road is not cut into the hillside. Minimal grading will be required to add stone to the existing grade per the detail on the L-C101.
Q.42. Confirm generators are by Others.
A. Yes, Generator is by others.
Q.43. I just want to clarify that there is no micropile element in the lower terminal. One of the
GCs inquired about drawing L-S501 - Section 3 - Pier with regard to the "pile cap" section listed. Can you please confirm there are no micropiles in the lower terminal and these are in fact part of the footers.
A. No micro piles are included in this project. See addendum.
Q.44. Safety Netting – How do you propose to attach the safety netting to the structure?
A. Specifications for Fall Protections are included on Sheet S000 “Fall Protection Netting.”
Q.45. Safety Netting – What is the fall height that the netting needs to be designed for?
A. Netting is installed at elevation equal to work surface, so design fall height is zero.
Specifications for Fall Protections are included on Sheet S000 “Fall Protection Netting.”
Q.46. Wood Decking – Does the wood decking need to be a “true” 4x6 or will nominal dimensions be acceptable?
A. As stated in Section 061533 No. 4B – Dimensions are nominal dimensions.
Q.47. Geotechnical Report – Is there a geotechnical report available, and can you provide it?
A. Will be provided in the Addendum.
Q.48. On Page L-S503, detail 11 shows “2x12 Center Stringer” listed in two locations on the right side of the detail. It also shows 2x12 stringers on the left side of that same detail, but they are not drawn the same. Also, the right side would indicate wood stringers. Would that not be steel on the right side since it’s receiving metal grating?
A. The stairs are also wood. Sheets L-S105 and L-S503 were revised and reissued in the addendum set.
Q.49. On Page L-S503, detail 4 shows the double 2x12 stringers being through-bolted into the 6x6 wood post. On Page L-S105, detail 4 would appear to show the two (2) 2x12 stringers resting on part of the 6x6 posts, which would suggest that we would be notching the top of the 6x6 post to receive the 2x12 stringers, then through-bolting them to the remaining portion of the 6x6 post. Which is correct?
A. Splices shall not occur at post locations. Sheets L-S105 and L-S503 were revised and reissued in the addendum set.
Q.50. On Page L-S105, detail 1 shows the beginning of the ramp and labels it as a “Landing”. It also shows wood framing for that landing, just like the other landings on the ramp. However, on Page L- S501, detail 2 shows the “Section At End Of Ramp” and shows a footing, plus a slab in that same area.
Which is correct?
A. The landing at the bottom of the ramp is concrete. Sheet L-S105 and L-S501 were revised and reissued in the addendum set.
Q.51. On Page L-S105, detail 1 shows the stairs on the far left side with steel grating on the stairs. This would suggest that these are steel framed stairs. However, on Page L-S504, detail 4 shows a “Stair Connection Detail” and calls out 2x12 stringers and 4x6 wood decking. Detail 1 on Page L-A302 would also suggest wood framing and decking for that same set of stairs. Which is correct?
A. The stairs are also wood. Sheets L-S105 and L-S503 were revised and reissued in the addendum set.
Q.52. Can we get a detail for the railing for the wood stairs? Need to know what the material needs to be, how it’s connected to the wood framing, etc.
A. It is the same as detail on 1/UA501
Q.53. The upper platform appears to be within the Town of Anstead Limits where the 2% Business & Occupancy Taxes would be applicable. The lower platform appears to be outside of the Town of Anstead Limits where the 2% Business & Occupancy Taxes would not be appliable.
Possible savings is estimated to be $60-80K for not including B&O by General Contractor’s & Subcontractor’s on the lower landing. To save the State of West Virginia revenue, should the upper & lower landing costs be separated on the bid form?
A. We will request the platforms of the upper and lower sections to be separated in the schedule of values for invoicing purposes. The B & O Taxes can be identified in this schedule of values for the successful contractor.
Q.54. Confirm the loading dock at the upper platform may be utilized for concrete pumping and crane activities through coordination efforts with on-site Owner’s representative.
A. Yes, subject to the coordination with the DNR.
Q.55. Sheet S000, Special Note 5. Where underpinning and/or shoring is required, the method and sequence shall be submitted to the Engineer for review prior to starting field operations.
A. Yes
Q.56. Where on the upper and/or lower platforms is it anticipated underpinning and/or shoring may be required?
A. Contractor shall determine if and where shoring is required to facilitate the construction.
Q.57. Will engineered drawings be required for underpinning and/or shoring?
A. If underpinning and shoring are required, drawings will be required.
Q.58. Referring to Sheets; U-S101, U-S501, Details 4/U-S501 & 5/U-S501. Due to the proposed grade elevations underneath the platform, confirm footings & cheek walls are not required for the concrete steps.
A. Cheek walls are neither required nor desired.
Q.59. Referring to Sheets; U-S101, U-S501, Details 4/U-S501, 5/U-S501, U-A101, U-A201, U- A202 & U-A501. Where can I find the mounting details for the railings at the concrete steps between the existing building and proposed platform?
A. See addenda drawings U-A101 and U-A101 Drawing for Detail.
Q.60. Referring to Sheet U-S101; could an existing elevation be provided for the top of manhole cover?
A. Existing manhole is to remain in place and protected during construction.
Q.61. Referring to Sheet U-S502; for clarity and bidding purposes, could the existing contours and proposed finish contour lines of the rip rap be drawn on the column schedule?
A. Contours at both stations are shown on U-C101 and L-C101. Finish grade and existing grade are the same.
Q.62. Confirm the existing pedestrian tail leading to the lower platform is being widened by Dopplemayer for their crane access and this widened access road will be available to the Platform Contractor’s gravel, concrete, steel deliveries and heavy equipment access.
A. Both Doppelmayr and this contractor are responsible for maintaining and/or upgrading the trail as per their respective needs.
Q.63. Can we have the column schedule for the lower station, L-S502 was missing from the drawings?
A. This is included in Addendum.
Q.64. There are notes in the specifications about moment connections and designing them.
However, there are no symbols on the drawings calling out moment connections. There is a detail (2/L-S501) that is a splice connection, but that has full pen welds.
A. Contractor is directed to canopy framing sheets U-S104 and L-S104. Design moments for HSS-HSS CJP welds are shown on plan and per notes.
Q.65. On the foundation caisson’s, what are the required loads for the following: Lateral DL , Tension DL, Compression D
A. Maximum factored (LRFD) reactions at top of caisson are as follows: Compression = 50 kip, Tension = 5 kip, Lateral = 8 kip.
Q.66. I just noticed that drawing L-S502 is missing from the plan set for Hawks Nest
A. This is included in Addendum.
Clarifications:
1. Upper station (B-3, B-5).
Drilled shaft caissons with an end bearing value of 20 ksf would be appropriate. The borings do not provide enough information to establish top of rock, and that will have to be determined in the field by a geotechnical engineer.
2. Lower station (B-1, B-2).
Spread footings would be appropriate in the wet sand or (preferably) the clay layer using a bearing value of 3000 psf.
@ AT
A.B. ANCHOR BOLT
ABC AGGREGATE BASE COURSE
ABV ABOVE
A/C AIR CONDITIONING
AC AMORED CABLE
ACS ACCESS
ACST ACOUSTIC, ACOUSTICAL
A.C.T. ACOUSTIC CEILING TILE
ACP ASPALTIC CONCRETE PAVING
AD ACCESS DOOR
ADD. ADDITIONAL
ADJ ADJACENT
AED AUTOMATIC EXTERNAL DEFIBRILLATOR
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AHR ANCHOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ALT ALTERNATE
ANCH. ANCHOR
ANG BM ANGLE BEAM
ANOD ANODIZED
AP ACCESS PANEL
APP ATACTIC PROPYLENE
APPR APPROVED
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL, ARCHITECT
ASPH ASPHALT
AUTO. AUTOMATIC
AVG AVERAGE
(B) BOTTOM
B/ BOTTOM OF
B PL BASE PLATE
BAF BAFFLE
BB BASEBOARD
BD BOARD
BD FT BOARD FEET
BDG BRIDGING
BDNG BEDDING
BET BETWEEN
BF BACK FACE
BFF BELOW FINISH FLOOR
BITUM BITUMINOUS
B OR BL BUILDING LINE, BASE LINE
BKBD BACKBOARD
BKG BACKING
B/L BEARING LINE
B/L BOUNDARY LINE
B/L BRACING LINE
BLDG BUILDING
BLKG BLOCKING
BLW BELOW
BLW FL BELOW FLOOR
BM BEAM, BENCH MARK
B.N. BOUNDARY NAILING
BOT BOTTOM
BR BARE ROOT
BRG BEARING
BRK BRICK
BRLP BURLAP
BRZ BRONZE
BSMT BASEMENT
BSP BLACK STEEL PIPE
C/C, C TO C CENTER TO CENTER
C CONC CAST CONCRETE
CAB CABINET
CANT., CANTIL CANTILEVER
CANV CANVAS
CB CEMENT BASE
CBF CONCENTRICALLY BRACED FRAME
C.E. CONTINUOUS END
CEM CEMENT
CEM FIN CEMENT FINISH
CEM PLAS CEMENT PLASTER
CF CEMENT FLOOR
CG CORNER GUARD
CHKR CHECKER, CHECKERED
CH BD CHALKBOARD
CHR PL CHROME PLATED
CI CAST IRON
CIP CAST IRON PIPE
CISP CAST IRON SOIL PIPE
CJ CONTROL JOINT
C/L, ~C CENTER LINE
CLDG CLADDING
CLG CEILING
CLO CLOSET
CLR CLEAR
CLWG CLEAR WIRED GLASS
CMP CORRUGATED METAL PIPE
CMPSN COMPOSITION
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNR CORNER
CO CLEANOUT
COL COLUMN
COMP COMPRESSED, COMPOSITE
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUATION
CONTR CONTRACT, CONTRACTOR
CORR CORRUGATED, CORRIDOR
CP CEMENT PIPE
CPT CARPET
CRS COLD-ROLLED STEEL
CS CAST STONE
CSC CURED SEALED CONCRETE
CSN. JT. CONSTRUCTION JOINT
CSP CEMENT SEWER PIPE
CSTL CAST STEEL
CT CERAMIC TILE
CT STN CUT STONE
CTB CERAMIC TILE BASE
CTR CENTER
CU. FT. CUBIC FOOT
CU YD CUBIC YARD
CULV CULVERT
DAT DATUM
DBL DOUBLE
D.E. DECK EDGE; DISCONTINUOUS END
DEC DECIDUOUS
DEM DEMOUNTABLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DFT DRY FILM THICKNESS
DI DROP INLET, DUCTILE IRON
DIA DIAMETER
DIR DIRECTION
DISP DISPENSER
DL DEAD LOAD
DMH DROP MANHOLE
DN DOWN
D.O.S. DIAMETER OF SHAFT
DOUG FIR DOUGLAS FIR
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWV DRAIN, WASTE, VENT
(E) EXISTING (CONSTRUCTION)
(E) EPOXY-COATED (REBAR)
EA EACH
EBF ECCENTRICALLY BRACED FRAME
EC EDGE OF CURB
E.E. EACH END
E.F. EACH FACE
EFC EXPOSED FINISHED CONCRETE
EIFS EXTERIOR INSULATION & FINISHING SYSTEM
EL ELEVATION
ELEC. ELECTRIC
ELEV ELEVATOR
E.T.B. ELEVATION TOP OF BEAM
E.T.F. ELEVATION TOP OF FOOTING
E.T.S. ELEVATION TOP OF SHAFT
E.T.W. ELEVATION TOP OF WALL
E.N. EDGE NAILING
ENGR ENGINEER
EOS EDGE OF SLAB
EPX EPOXY POURED FLOOR
EQ EQUAL
EQUIP EQUIPMENT
EV EVERGREEN
E.W. EACH WAY
EWC ELECTRIC WATER COOLER
EXC EXCAVATE, EXCAVATION
EXH EXHAUST
EXP EXPOSED
EXP JT EXPANSION JOINT
EXPS EXPOSED PAINTED STRUCTURE
EXIST EXISTING
EXT EXTERIOR
F TO F FACE TO FACE
FAS FASCIA
FC BRK FACE BRICK
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR, FRONT FACE
FGL FIBERGLASS
FHYD FIRE HYDRANT
FIN FINISH
FL FLOOR
FL FIN CONC FLOAT FINISH CONCRETE
FLEX FLEXIBLE
FLG FLANGE
FLSH FLASHING
FMBD FORM BOARD
F.O., F/O FACE OF
FRT FIRE RESISTANT TREATED
FS FAR SIDE
FT FOOT, FEET
FTG FOOTING
FUR FURRED (ING)
FURN FURNISH
G GIRDER
GA GAGE, GAUGE
GALV GALVANIZE, GALVANIZED
GC GENERAL CONTRACTOR
GFE GOVERNMENT FURNISHED EQUIPMENT
GFECI GOVERNMENT FURNISHED EQUIPMENT,
CONTRACTOR INSTALLED
GFM GOVERNMENT FURNISHED MATERIAL
GFRC GLASS-FIBER REINFORCED CONCRETE
GFRG GLASS-FIBER REINFORCED GYPSUM
GFRP GLASS-FIBER REINFORCED PLASTER
GL GLASS
GL BLK GLASS BLK
GLZ GLAZING
GOVT GOVERNMENT
GR GRADE
GRND GROUND
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GUT GUTTER
GVL GRAVEL
GYP GYPSUM
GYP PLAS GYPSUM PLASTER
GWB GYPSUM WALLBOARD
HC HOLLOW CORE
HC HOLLOW CORE MASONARY UNIT
HD HEAD
HDBD HARDBOARD
HDR HEADER
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HYD HYDRANT
IB I BEAM
I.D. INSIDE DIAMETER
I.F. INSIDE FACE
I.F.H. INSIDE FACE HORIZONTAL
I.F.V. INSIDE FACE VERTICAL
INFL INFLUENT
INN INNER
INSUL INSULATION
INV INVERT, INVERSE
IP IRON PIPE, IRON PIN
ISO. JT. ISOLATION JOINT
JBE JOIST BEARING ELEVATION
JC JANITOR'S CLOSET
JST JOIST
JT JOINT
K THOUSAND
KIP KILO-POUND (1000 POUNDS)
LA LAMINATE
LAM GL LAMINATED GLASS
LAT LATTICE
LAV LAVATORY
LAY LAYER
LBR LUMBER
LD BEARING LOAD BEARING
LKR LOCKER
LIVE LOAD LIVE LOAD
LL GB LEAD LINED GYPSUM BOARD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LPS LIQUID PENETRATING SEALER
LSL LONG SLOT
LT LEFT
LWC LIGHTWEIGHT CONCRETE
MAHOG MAHOGONY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
M.F. MOMENT FRAME
MTL METAL
MFR, MFGR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MK MARK
MO MASONRY OPENING
MON MONUMENT
MR RECEPTOR MOP
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MWFRS MAIN WIND FORCE RESISTING SYSTEM
MWP MEMBRANE WATERPROOFING
(N) NEW (CONSTRUCTION)
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NKL NICKEL
NLB NON LOAD BEARING
NO.,NOS NUMBER, NUMBERS
NS NEAR SIDE
NS/FS NEAR SIDE AND FAR SIDE
NTS NOT TO SCALE
O TO O OUT TO OUT
OA OVERALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OUTSIDE FACE
OGL OBSCURE GLASS
O.H. OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
OPQ OPAQUE
OSB ORIENTED STRAND BOARD
OVHD OVERHEAD
OVS OVERSIZE(D)
OWGL OBSCURE WIRED GLASS
PAGB PAINTED ABUSE RESISTANT GYPSUM BOARD
PAR PARAPET
PBD PARTICLE BOARD
PC, P.C. PORTLAND CEMENT, PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCP PRECAST CONCRETE PANEL
PCS PAINTED CONCRETE SURFACE
PCT PORCELAIN CERAMIC TILE
PED PEDESTAL
PEG PEG BOARD
PH PHASE
PI POINT OF INTERSECTION
PIB POLYISOBUTYLENE
PIGB PAINTED IMPACT RESISTANT GYPSUM BOARD
PL PLATE
PLBG PLUMBING
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLATF PLATFORM
PLF POUNDS PER LINEAL FOOT
~P PLATE
± PLUS/MINUS
PLYWD PLYWOOD
PMBC PLANT MIX BITUMINOUS CONCRETE
PMGB PAINTED MOISTURE RESISTANT GYPSUM BOARD
PNL PANEL
PNT PAINT
POL POLISH, POINT OF LINE
POLY POLYETHYLENE
PORC PORCELAIN
POTW POTABLE WATER
PP POLYPROPYLENE
PPGL POLISHED PLATE GLASS
PS POLYSTYRENE
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PT PRETENSIONED
PTN PARTITION
P. T. PRESSURE TREATED
PUR PURLINS
PVA POLYVINYL ACETATE
PVC POLYVINYL CHLORIDE
PVF POLYVINYL FLOURIDE
PVMT PAVEMENT
QT QUARRY TILE
Ø ROUND (DIAMETER)
R RISER
R/W RIGHT OF WAY
RAD. RADIUS
RB RUBBER BASE
RBR. RUBBER
RC REINFORCED CONCRETE
RD ROOF DRAIN, ROAD
REBAR REINFORCING STEEL BAR
RECVG. RECEIVING
REC. RECESS
REF. REFERENCE
REFL. REFLECTED
REINF. REINFORCED, REINFORCEMENT
REQD. REQUIRED
RESIL. RESILIENT
REV. REVISION
RF. ROOF
RFS RUBBER FLOORING SYSTEM
RFG. ROOFING
RFH ROOF HATCH
RL ROOF LEADER
RM. ROOM
RO ROUGH OPENING
RR ROLL ROOFING
RRB RESILIENT RUBBER BASE
RST REINFORCING STEEL
RT RIGHT
RUB RUBBER FLOORING
RVB RESILIENT VINYL BASE
RW REDWOOD
SAF SYNTHETIC ATHLETIC FLOORING
SAN SANITARY
SB SPLASH BLOCK
SC SOLID CORE, SLIP-CRITICAL
SCT STRUCTURAL CLAY TILE
SD STORM DRAIN
SEC SECRETARY
SECT SECTION
SF SQUARE FOOT
SFP SPRAYED FIRE PROTECTION
SFTWD SOFTWOOD
SG SILTY GRAVEL
SH SHINGLES
SHT SHEET
SHTHG SHEATHING
SHT MTL SHEET METAL (FLASHING)
SHV SHELVING
SIM SIMILAR
SM SHEET METAL
SMP SOLID MASONRY PIER
SMB SMART BOARD
SP SPACE, SPACES
SPEC SPECIFICATION
SPF SPRUCE-PINE-FIR
SPR SPRINKLER
SQ SQUARE
SQ BR SQUARE BAR
SS SANITARY SEWER, STAINLESS STEEL
SSD SURFACE DRAIN
SSL SHORT SLOT
SSM SOLID SURFACE MATERIAL
SSP STAINLESS STEEL PIPE
SST STAINLESS STEEL
ST STREET, SNUG-TIGHTENED
STA STATION
STD STANDARD
STL STEEL
ST GL STAINED GLASS
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STS STEEL TROWELED SURFACE
STRUCT STL STRUCTURAL STEEL
STRUCT STRUCTURE, STRUCTURAL
STSTL STAINLESS STEEL
SUBSTA SUBSTATION
SUP SUPPLY
SURF SURFACE
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK, SHEARWALL
SYM SYMMETRIC
SYNTH SYNTHETIC
(T) TOP
T/ TOP OF
T TREAD
T & B TOP AND BOTTOM
T & G TONGUE AND GROOVE
TBE TRUSS BEARING ELEVATION
TC TERRA COTTA
TD TRENCH DUCT
TEL TELEPHONE
TEJ TRANSVERSE EXPANSION JOINT
TEMP TEMPERATURE
T/F, T/FTG. TOP OF FOOTING
THK THICK
THRES THRESHOLD
TKBD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TMPD HDBD TEMPERED HARDBOARD
TN TRUE NORTH
T O C TOP OF CONCRETE
T.O.S. TOP OF SLAB
TRTD TREATED
TS TUBE STEEL
T/S TOP OF STEEL
T/W TOP OF WALL
TYP TYPICAL
U.L. UNDERWRITERS LABORATORY
U.O.N. UNLESS OTHERWISE NOTED
UNPV RD UNPAVED ROAD
UR URINAL
U.S. URINAL SCREEN
UTIL UTILITY
VAT VINYL ASBESTOS TILE
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VT VINYL TILE
VW VINYL WOOD
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WATER MAIN
W/, w/ WITH W/O, w/o WITHOUT
WA WAINSCOT
WB WOOD BASE
WBL WOOD BLOCKING
WBS WROUGHT BRASS
WDC WOOD CLAD
WC WATER CLOSET
WD WOOD
WDPT WOOD (PRESSURE TREATED)
WDW WINDOW
WF WIDE FLANGE
WFR WOOD FRAME
WGL WIRED GLASS
WI WROUGHT IRON
WM WIRE MESH
WMP WIRE MESH PARTITION SYSTEM
WP WORKING POINT, WEATHERPROOF
WPF WATERPROOFING
WPM WATERPROOF MEMBRANE
WS WEATHER STRIP
WR WIRE ROPE
WSL WEATHER SEAL
WST WASTE
WT WINDOW TYPE
WTR WATER
WVC WOOD VENEER WALL COVERING
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WWR WELDED WIRE REINFORCEMENT
A101
SIM
CONCRETE
CLAY UNIT MASONRY
CONCRETE UNIT MASONRY
WOOD FRAMING
PLYWOOD
FINISHED WOOD
BATT INSULATION
RIGID INSULATION
GYPSUM BOARD
SOIL
CRUSHED STONE
CENTER LINE
HIDDEN LINE
VIEW TITLE
SYMBOL DESCRIPTION
A101
SIM
A101
4 2 ELEVATION MARKER
SECTION MARKER
DETAIL CALLOUT
ROOM TAG
GRID LINE MARKER
ELEVATION DATUM
SPOT ELEVATION MARK
WALL TAG
WALL REINFORCING TAG
DOOR TAG
WINDOW TAG
ROOM
NAME
View Name
SCALE: 1/8" = 1'-0"
A101
SHEET NUMBER
SHEET DETAIL NUMBER
C4
LEVEL
ELEVATION
PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE.
FURNISH: SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING,
ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS.
INSTALL: UNLOAD, TEMPORARILY STORE, UNPACK, ASSEMBLE, ERECT, PLACE, ANCHOR, APPLY, WORK TO DIMENSION, FINISH, CURE, PROTECT, CLEAN, AND SIMILAR OPERATIONS AT PROJECT
SITE.
EXISTING TO REMAIN (OR EXISTING) (OR EX.): LEAVE EXISTING ITEMS THAT ARE NOT TO BE
REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE SALVAGED OR REINSTALLED.
REMOVE (OR DEMOLISH) (OR DEMO): DETACH ITEMS FROM EXISTING CONSTRUCTION AND
DISPOSE OF THEM OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLED.
REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO
PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE.
REMOVE AND REINSTALL (OR REMOVE AND REUSE): DETACH ITEMS FROM EXISTING
CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, PREPARE FOR REUSE, AND REINSTALL
WHERE INDICATED.
DISMANTLE: TO REMOVE BY DISASSEMBLING OR DETACHING AN ITEM FROM A SURFACE, USING
GENTLE METHODS AND EQUIPMENT TO PREVENT DAMAGE TO THE ITEM AND SURFACES;
DISPOSING OF ITEMS UNLESS INDICATED TO BE SALVAGED OR REINSTALLED.
DISPOSE: REMOVAL OFF-SITE OF DEMOLITION AND CONSTRUCTION WASTE AND SUBSEQUENT
SALE, RECYCLING, REUSE, OR DEPOSIT IN LANDFILL OR INCINERATOR ACCEPTABLE TO
AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH PROJECT REQUIREMENTS.
"U" PREFIX IN SHEET NUMBER: PERTAINS TO UPPER STATION
"L" PREFIX IN SHEET NUMBER: PERTAINS TO LOWER STATION
ALPHA ASSOCIATES, INC.
209 PRAIRIE AVENUE
MORGANTOWN, WV 26501
PHONE/FAX: 304-296-8216
TOLL FREE: 800-640-8216
www.thinkALPHAfirst.com
COPYRIGHT 2024 ALPHA ASSOCIATES, INC.
ALL RIGHTS RESERVED
REVISIONS
PROJ. NO.:
DATE:
SHEET NO.:
FO
R
/2
4/
0:
:5
AM
C :\U se rs
\tl ew is \D oc um en ts
\R ev it\ H aw k's
N es t U pp er S ta tio n_ to dd le w is
.rv t
G001
ABBREV & SYMBOLS
2112149.00
HA
W
KS
N
ES
T U
PP
ER
A N
D
LO
W
ER
TE
RM
IN
A
LS
W V
DE
PT
O F
N A
TU
RA
L
RE
SO
UR
C
ES
10/23/2024
IS
SU
ED
F
O R
BI
DD
IN
G
A N
ST
ED
, W
ES
T V
IR
G
IN
IA
ABBREVIATIONS SYMBOL LEGEND
DEFINITIONS
1. THIS PROJECT HAS BEEN DESIGNED IN
ACCORDANCE WITH THE 2018 INTERNATIONAL
BUILDING CODE, THE LIFE SAFETY CODE (NFPA
101-2021) AND THE STATE FIRE CODE.
2. WRITTEN SPECIFICATIONS FOR THE PROJECT ARE
PROVIDED TO ESTABLISH AND MAINTAIN A LEVEL OF
MANUFACTURE AND QUALITY. ALL SUBSTITUTION
REQUESTS MUST BE MADE IN WRITING NO LESS
THAN (10) BUSINESS DAYS PRIOR TO THE DATE OF
THE BID. ANY ACCEPTED SUBSTITUTION SHALL BE
MADE BY WRITTEN ADDENDUM FROM THE OFFICE OF
THE ARCHITECT PRIOR TO THE BID DATE.
3. CONSTRUCTION METHODS, PROCEDURES AND
SEQUENCES ARE THE RESPONSIBILITY OF THE
CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL
NECESSARY MEANS TO MAINTAIN AND PROTECT THE
STRUCTURAL INTEGRITY OF ALL CONSTRUCTION AT
ALL STAGES. THE DESIGN FIRM(S) SHALL NOT BE
RESPONSIBLE FOR THE NEGLIGENCE OF THE
CONTRACTOR(S), SUB-CONTRACTOR(S) OR ANY
OTHER PERSON(S) INVOLVED IN THE WORK, OR IN
THE FAILURE OF SAID PERSON(S) TO CARRY OUT
THE WORK IN ACCORDANCE WITH THE CONTRACT
DOCUMENTS.
4. WRITTEN SPECIFICATIONS SHALL SUPERSEDE
DRAWINGS.
5. DIMENSIONS SHALL SUPERSEDE DRAWINGS. DO
NOT SCALE DRAWINGS. WHERE A MISSING OR
CONFLICTING DIMENSION OCCURS, THE ARCHITECT
SHALL BE CONTACTED IMMEDIATELY TO OBTAIN THE
NECESSARY CLARIFICATION.
6. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
OF ANY AND ALL DISCREPANCIES BETWEEN THE
DRAWINGS AND ACTUAL FIELD CONDITIONS
IMMEDIATELY UPON DISCOVERY.
7. COMMENCEMENT OF THE WORK SHALL SIGNIFY THE
CONTRACTOR IS FAMILIAR WITH AND AGREES TO
THE SCOPE OF WORK AS OUTLINED IN THE
CONTRACT DOCUMENTS.
8. THE CONTRACTOR SHALL ABIDE BY ALL SAFETY
RULES AND REGULATIONS IMPOSED BY OSHA AND
THE OWNER AT ALL TIMES. IF THERE IS A CONFLICT
BETWEEN THE TWO, THE STRICTER REGULATION
SHALL APPLY.
9. THE CONTRACTOR SHALL TAKE ALL NECESSARY
MEANS TO MAINTAIN AND PROTECT ADJACENT
PROPERTY FROM DAMAGE DURING THE PROCESS
OF THE WORK.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROPER DISPOSAL OF ALL MATERIALS RESULTING
FROM THE WORK OF THIS PROJECT. THE PROJECT
SITE SHALL AT ALL TIMES BE MAINTAINED IN AN
ORDERLY MANNER SO AS TO MINIMIZE
ACCUMULATION OF WASTE AND/OR SURPLUS
MATERIALS. PROPER DISPOSAL RECEIPTS SHALL BE
OBTAINED AND RETAINED FOR OWNER'S REVIEW.
AT THE COMPLETION OF THE WORK THE
CONTRACTOR SHALL REMOVE ALL DEBRIS, SURPLUS
MATERIAL AND CONSTRUCTION EQUIPMENT FROM
THE PREMISES.
11. SHOP DRAWINGS ARE REQUIRED AS LISTED IN THE
PROJECT MANUAL.
GENERAL NOTES
PROJECT IS TO PROVIDE TWO OUTDOOR DECKS PARTIALLY
COVERED BY CANOPIES ADJACENT TO TRAM DOCKING
AREAS AT BOTH UPPER AND LOWER STATIONS OF TRAMWAY.
PROJECT SUMMARY
No. ITEM DATE
047300 MANUAFACTERED STONE
1. PORTLAND CEMENT BASED MANUFACTURED STONE.
2. BASIS OF DESIGN: ELDORADO STONE, LLC-COUNTRY RUBBLE MILLSTREAM EASTERN -2.5" THICKNESS
3. VENEER UNIT PROPERTIES: PRECAST VENEER UNITS CONSISTING OF PORTLAND CEMENT,
LIGHTWEIGHT AGGREGATES, AND MINERAL OXIDE PIGMENTS.PROVIDE CORNER STONES FOR
COLUMN BASES.
4. WEATHER BARRIER: ICC AC-38, SYNTHETIC HOUSE WRAP
5. REINFORCING: ASTM C 847, 2.5LB/YD2 (1.4KG/M2) GALVANIZED EXPANDED METAL LATH COMPLYING
WITH CODE AGENCY REQUIREMENTS FOR THE TYPE OF SUBSTRATE OVER WHICH STONE VENEER IS
INSTALLED.
6. WATER REPELLENT: WATER BASED SILANE OR SILOXANE MASONRY WATER REPELLENT
7. MORTAR MIXES. STANDARD INSTALLATION (GROUTED JOINTS):MIX MORTAR IN ACCORDANCE WITH
ASTM C 270, POLYMER MODIFIED MORTAR COMPLYING WITH ANSI A118.4
8. STANDARD SAMPLE BOARD CONSISTING OF SMALL-SCALE PIECES OF VENEER UNITS SHOWING FULL
RANGE OF TEXTURES AND COLORS.FULL RANGE OF MORTAR COLORS.
9. INSTALLER QUALIFICATIONS: EXPERIENCED MASON FAMILIAR WITH INSTALLATION PROCEDURES AND
RELATED LOCAL, STATE AND FEDERAL CODES MASONRY.
10. FIELD SAMPLE:PREPARE ONE COLUMN WRAP SAMPLE AT A LOCATION ON THE STRUCTURE AS
SELECTED BY THE ARCHITECT. USE APPROVED SELECTION SAMPLE MATERIALS AND COLORS.OBTAIN
ARCHITECT’S APPROVAL. APPROVED SAMPLE MAY BE INCORPORATED INTO COMPLETED WORK.
11. FOLLOW MANUFACTURER’S INSTRUCTIONS FOR DELIVERY, STORAGE AND HANDLING.
12. MANUFACTURER’S STANDARD WARRANTY COVERAGE AGAINST DEFECTS IN MATERIALS WHEN
INSTALLED IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS.
13. INSTALL AND CLEAN STONE IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS
FOR STANDARD INSTALLATION GROUTED JOINT INSTALLATION AS SPECIFIED ABOVE.
047300 MANUAFACTERED STONE COLUMN CAP
1. BASIS OF DESIGN: ELDORADO STONE, LLC-CHISELED EDGE PEAKED COLUMN CAP-18"X18"X2.5". CAP
PEAK AT 5.5".
2. COLOR TO BE SELECTED BY ARCHITECT FROM MANUFACTURERS FULL RANGE OF COLORS.
3. FOLLOW MANUFACTURER’S INSTRUCTIONS FOR DELIVERY, STORAGE AND HANDLING.
4. MANUFACTURER’S STANDARD WARRANTY COVERAGE AGAINST DEFECTS IN MATERIALS WHEN
INSTALLED IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS.
5. INSTALL AND CLEAN STONE CAP IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION
INSTRUCTIONS FOR STANDARD INSTALLATION GROUTED JOINT INSTALLATION AS SPECIFIED ABOVE.
6. CUT COLUMN CAP IN FIELD TO ALLOW FOR STRUCTURAL SUPPORT
MISCELLANEOUS MATERIALS-SHEET METAL FLASHING, GUTTER AND DOWNSPOUTS
1. ALL MISCELLANEOUS MATERIALS-SHEET METAL FLASHING, BOX GUTTER AND SQUARE
DOWNSPOUTS SHAPE, PROFILE, COLOR AND THICKNESS TO BE SELECTED BY ARCHITECT
FROM FULL RANGE.
2. BASIS OF DESIGN: METAL-ERA SEAL-TITE LT. GUTTERS TO BE 22 GA. STEEL 6" BOX GUTTERS.
GUTTER TO HAVE A 30 YEAR PVDF KYNAR 500 FINISH. COLOR TO BE SELECTED FROM
ARCHITECTS FULL RANGE OF MANUFACTURERS COLORS.
3. CUSTOM SIZED GUTTER AS SHOWN ON THE DRAWING(S). GUTTER SECTIONS: LENGTH OF
10'-0”
4. ALL GUTTER, REGARDLESS OF METAL SUBSTRATE OR THICKNESS IS TO BE PRE-
MANUFACTURED.
5. ALL GUTTER TO BE SUPPORTED BY GUTTER SUPPORT BRACKETS ON 24” CENTERS THAT ARE
1.0” WIDE X .1875” STAINLESS/ GALVANIZED THICK BAR STOCK AND THEN WRAPPED ON ALL
VISIBLE SIDES AFTER INSTALLATION WITH THE SAME METAL AS THE GUTTER MATERIAL.
6. THERE SHALL BE NO HOLES PUT IN THE GUTTER DURING THE FABRICATION OF OR
INSTALLATION OF THE GUTTER.
7. ALL GUTTER SECTIONS TO BE CONNECTED USING INTERNAL SPLICE PLATES MADE FROM
SAME MATERIAL AND FINISH AS THE GUTTER.
8. BASIS OF DESIGN: METAL-ERA SEAL-TITE LT. DOWNSPOUT TO BE 22 GA. STEEL 6" SQUARE
DOWNSPOUT. DOWNSPOUT TO HAVE A 30 YEAR PVDF KYNAR 500 FINISH. COLOR TO BE
SELECTED FROM ARCHITECTS FULL RANGE OF MANUFACTURERS COLORS.
9. CUSTOM SIZED DOWNSPOUT AND ELBOWS AS SHOWN ON THE DRAWINGS. DOWNSPOUT
SECTIONS: LENGTH AS SHOWN ON DRAWINGS.
10. ALL DOWNSPOUTS SHALL BE CONNECTED TO GUTTER USING A FACTORY FABRICATED
OUTLET TUBE CONSTRUCTED FROM THE SAME MATERIAL AS THE DOWNSPOUT.
11. ALL DOWNSPOUT AND ELBOW IS TO BE ROLL-FORMED (NOT TO BE FABRICATED ON A METAL
FOLDER OR BREAK PRESS).
12. ALL DOWNSPOUT, ELBOWS & OFFSETS MUST HAVE INTERLOCKING, ACME LOCK SEAMS.
13. ALL DOWNSPOUTS AND ELBOWS TO HAVE ONE END CRIMPED FOR SECURE ASSEMBLY.
14. PROVIDE TWO (2) FACTORY FABRICATED DOWNSPOUT ANCHOR STRAPS PER 10’ SECTION.
15. PROVIDE FACTORY FABRICATED ELBOWS AND OFFSETS (ONE PIECE SECTIONS PREFERRED).
16. ALL GUTTER CORNERS, END CAPS, EXPANSION JOINTS, OUTLET TUBES, ETC. SHALL BE
FABRICATED BY THE GUTTER AND DOWNSPOUT MANUFACTURER.
17. ALL ACCESSORIES TO BE FABRICATED FROM SAME METAL STOCK AND FINISH AS GUTTER
AND DOWNSPOUT. NO POST PAINTING OF PRODUCT.
18. FLASHING,TRIM, GRAVEL STOP: PROVIDE FLASHING AND TRIM FORMED AS REQUIRED TO
SEAL AGAINST WEATHER AND TO PROVIDE FINISHED APPEARANCE. LOCATIONS INCLUDE,
BUT ARE NOT LIMITED TO, EAVES, RAKES, CORNERS, RIDGES, AND FASCIA. FINISH FLASHING
AND TRIM WITH SAME FINISH SYSTEM AS ADJACENT GUTTERS AND DOWNSPOUTS.
19. JOINT SEALANT: ASTM C 920; AS RECOMMENDED IN WRITING BY DOWNSPOUT AND GUTTER
MANUFACTURER
20. BUTYL-RUBBER-BASED, SOLVENT-RELEASE SEALANT: ASTM C 1311.
075323 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING
1. PROVIDE PRODUCT DATA FOR EACH TYPE OF PRODUCT. PROVIDE SHOP DRAWINGS: FOR
ROOFING SYSTEM:INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS
TO OTHER WORK. PROVIDE SAMPLES FOR VERIFICATION FOR THE FOLLOWING PRODUCTS:
SHEET ROOFING, OF COLOR REQUIRED.
2. MANUFACTURER AGREES TO REPAIR OR REPLACE COMPONENTS OF ROOFING SYSTEM
THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY PERIOD.
3. WARRANTY PERIOD: 20 YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
4. TYPE: TOTAL ROOFING SYSTEM, NO DOLLAR LIMIT ON LABOR AND MATERIAL. OBTAIN
COMPONENTS INCLUDING ROOF INSULATION AND FASTENERS FOR ROOFING SYSTEM FROM
SAME MANUFACTURER AS MEMBRANE ROOFING OR MANUFACTURER APPROVED BY
MEMBRANE ROOFING MANUFACTURER.
5. EPDM: ASTM D 4637, TYPE II, SCRIM OR FABRIC INTERNALLY REINFORCED, UNIFORM,
FLEXIBLE EPDM SHEET. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,
PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: CARLISLE SYNTEC INCORPORATED,
FIRESTONE BUILDING PRODUCTS. OR JOHNS MANVILLE.
6. THICKNESS: 90 MILS (1.5 MM), NOMINAL.
7. EXPOSED FACE COLOR: BLACK.
8. AUXILIARY MATERIALS RECOMMENDED BY ROOFING SYSTEM MANUFACTURER FOR
INTENDED USE AND COMPATIBLE WITH ROOFING.
9. LIQUID-TYPE AUXILIARY MATERIALS SHALL COMPLY WITH VOC LIMITS OF AUTHORITIES
HAVING JURISDICTION.
10. SHEET FLASHING: 90-MIL- (1.5-MM-) THICK EPDM, PARTIALLY CURED OR CURED, ACCORDING
TO APPLICATION.
11. PROTECTION SHEET: EPICHLOROHYDRIN OR NEOPRENE NONREINFORCED FLEXIBLE SHEET,
55- TO 60-MIL- (1.4- TO 1.5-MM-) THICK, RECOMMENDED BY EPDM MANUFACTURER FOR
RESISTANCE TO HYDROCARBONS, NON-AROMATIC SOLVENTS, GREASE, AND OIL.
12. BONDING ADHESIVE: MANUFACTURER'S STANDARD.
13. SEAMING MATERIAL: MANUFACTURER'S STANDARD, SYNTHETIC-RUBBER POLYMER PRIMER
AND 3-INCH- (75-MM-) WIDE MINIMUM, BUTYL SPLICE TAPE WITH RELEASE FILM.
14. FASTENERS: FACTORY-COATED STEEL FASTENERS AND METAL OR PLASTIC PLATES
COMPLYING WITH CORROSION-RESISTANCE PROVISIONS IN FM GLOBAL 4470, DESIGNED FOR
FASTENING MEMBRANE TO SUBSTRATE, AND ACCEPTABLE TO ROOFING SYSTEM
MANUFACTURER.
15. MISCELLANEOUS ACCESSORIES: PROVIDE LAP SEALANT, WATER CUTOFF MASTIC, METAL
TERMINATION BARS, METAL BATTENS, POURABLE SEALERS, PREFORMED CONE AND VENT
SHEET FLASHINGS, MOLDED PIPE BOOT FLASHINGS, PREFORMED INSIDE AND OUTSIDE
CORNER SHEET FLASHINGS, REINFORCED EPDM SECUREMENT STRIPS, T-JOINT COVERS, IN-
SEAM SEALANTS, TERMINATION REGLETS, COVER STRIPS, AND OTHER ACCESSORIES.
16. ROOFING ASPHALT: ASTM D 312, TYPE III OR TYPE IV.INSTALL ROOFING SYSTEM ACCORDING
TO ROOFING SYSTEM MANUFACTURER'S WRITTEN INSTRUCTIONS.COMPLETE TERMINATIONS
AND BASE FLASHINGS AND PROVIDE TEMPORARY SEALS TO PREVENT WATER FROM
ENTERING COMPLETED SECTIONS OF ROOFING SYSTEM AT THE END OF THE WORKDAY OR
WHEN RAIN IS FORECAST. REMOVE AND DISCARD TEMPORARY SEALS BEFORE BEGINNING
WORK ON ADJOINING ROOFING.ADHERE ROOFING OVER AREA TO RECEIVE ROOFING
ACCORDING TO MEMBRANE ROOFING SYSTEM MANUFACTURER'S WRITTEN INSTRUCTIONS.
UNROLL MEMBRANE ROOFING AND ALLOW TO RELAX BEFORE INSTALLING.ACCURATELY
ALIGN ROOFING, AND MAINTAIN UNIFORM SIDE AND END LAPS OF MINIMUM DIMENSIONS
REQUIRED BY MANUFACTURER. STAGGER END LAPS. BONDING ADHESIVE: APPLY TO
SUBSTRATE AND UNDERSIDE OF ROOFING AT RATE REQUIRED BY MANUFACTURER, AND
ALLOW TO PARTIALLY DRY BEFORE INSTALLING ROOFING. DO NOT APPLY TO SPLICE AREA
OF ROOFING.IN ADDITION TO ADHERING, MECHANICALLY FASTEN ROOFING SECURELY AT
TERMINATIONS, PENETRATIONS, AND PERIMETERS.
17. ADHESIVE SEAM INSTALLATION: CLEAN BOTH FACES OF SPLICE AREAS, APPLY SPLICING
CEMENT, AND FIRMLY ROLL SIDE AND END LAPS OF OVERLAPPING ROOFING ACCORDING TO
MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE A WATERTIGHT SEAM
INSTALLATION. APPLY LAP SEALANT AND SEAL EXPOSED EDGES OF ROOFING TERMINATION.
APPLY A CONTINUOUS BEAD OF IN-SEAM SEALANT BEFORE CLOSING SPLICE IF REQUIRED BY
ROOFING SYSTEM MANUFACTURER. TAPE SEAM INSTALLATION: CLEAN AND PRIME BOTH
FACES OF SPLICE AREAS, APPLY SPLICE TAPE, AND FIRMLY ROLL SIDE AND END LAPS OF
OVERLAPPING ROOFING ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS TO
ENSURE A WATERTIGHT SEAM INSTALLATION. APPLY LAP SEALANT AND SEAL EXPOSED
EDGES OF ROOFING TERMINATIONS. REPAIR TEARS, VOIDS, AND LAPPED SEAMS IN ROOFING
THAT DO NOT COMPLY WITH REQUIREMENTS.
18. INSTALL SHEET FLASHINGS AND PREFORMED FLASHING ACCESSORIES, AND ADHERE TO
SUBSTRATES ACCORDING TO ROOFING SYSTEM MANUFACTURER'S WRITTEN
INSTRUCTIONS.APPLY BONDING ADHESIVE TO SUBSTRATE AND UNDERSIDE OF SHEET
FLASHING AT REQUIRED RATE, AND ALLOW TO PARTIALLY DRY. DO NOT APPLY TO SEAM
AREA OF FLASHING. FLASH PENETRATIONS AND FIELD-FORMED INSIDE AND OUTSIDE
CORNERS WITH CURED OR UNCURED SHEET FLASHING. CLEAN SPLICE AREAS, APPLY
SPLICING CEMENT, AND FIRMLY ROLL SIDE AND END LAPS OF OVERLAPPING SHEETS TO
ENSURE A WATERTIGHT SEAM INSTALLATION. APPLY LAP SEALANT AND SEAL EXPOSED
EDGES OF SHEET FLASHING TERMINATIONS. TERMINATE AND SEAL TOP OF SHEET
FLASHINGS AND…