A06_Drawings.pdf
PDF 14 MB Posted
- Attached to
- INDE - 408 LOCUST STREET ROOFS PROJECT
- Solicitation number
- 140P4221R0008
About this file
This document contains details of a federal contract opportunity for roof repair work. The National Park Service is soliciting proposals to repair and restore the roof at 408 Locust Street in Independence National Historical Park in Philadelphia, Pennsylvania. The contract value is estimated between $250,000 and $500,000. A firm fixed-price contract will be awarded based on an evaluation of technical factors and price. The solicitation requires compliance with wage determination PA20210003 and is set aside for small businesses. A pre-proposal site visit will be held on April 6, 2021 and all questions must be submitted by email to the contracting officer by a specified date prior to the proposal due date.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B12_Price Sheet_0001.xlsx | XLSX spreadsheet | |
| RFI Responses_0001.docx | DOCX document | |
| Sol_140P4221R0008_Amd_0001.pdf | ||
| A04_Specs.pdf | ||
| Past Performance.docx | DOCX document | |
| Experience Questionnaire.docx | DOCX document | |
| Hazardous Materials Form.doc | DOC document | |
| B12_Price Sheet.xlsx | XLSX spreadsheet | |
| Sol_140P4221R0008.pdf | ||
| B03_PA20210003 Wage Determination.pdf | ||
| General References.doc | DOC document | |
| Limitations on Subcontracting.xlsx | XLSX spreadsheet |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
PFS
WC
12/10/20
G1
408 LOCUST STREET
NORTH ELEVATION
COVER SHEET - SITE LOCATION
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
INDEPENDENCE NATIONAL HISTORICAL PARK (nts)
PHILADELPHIA, PA. (nts)
SITE ON LOCUST STREET (nts)
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
PFS
WC
12/10/20
G2
408 LOCUST STREET
NORTH ELEVATION
COVER SHEET - SITE LOCATION
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
LOCUST STREET VIEW
NOT TO SCALE
G2
COURTYARD VIEW
NOT TO SCALE
G2
COURTYARD VIEW
NOT TO SCALE
G2
COURTYARD VIEW
NOT TO SCALE
G2
GENERAL NOTES FOR 408 LOCUST STREET
1. 408 LOCUST STREET IS ON THE LIST OF CERTIFIED STRUCTURES, INDEPENDENCE NATIONAL HISTORICAL PARK AND IS LISTED AS A CONTRIBUTING STRUCTURE TO THE PARK'S NOMINATION TO THE NATIONAL
REGISTER. ALL WORK IS EXPECTED TO BE OF THE HIGHEST QUALITY.
2. THE CONTRACTOR SHALL HAVE USE OF THE SITE BETWEEN THE HOURS OF 7:00 AM AND 5:00 PM MONDAY
THROUGH FRIDAY DURING THE PERIOD OF PERFORMANCE. NO WORK IS TO BE PERFORMED ON
WEEKENDS OR FEDERAL HOLIDAYS UNLESS BY WRITTEN PERMISSION FROM THE PARK, SCHEDULED AT
LEAST 72 HOURS IN ADVANCE OF SUCH WORK.
3. NO PARKING IS ALLOWED ON PARK PROPERTY INCLUDING SIDEWALKS AND ROADWAYS. THE
CONTRACTOR MAY ARRANGE FOR PARKING PERMITS FOR ON STREET PARKING (CITY STREETS) THROUGH
THE CITY OF PHILADELPHIA PARKING AUTHORITY.
4. ALL WALKWAYS AND SIDEWALKS IN AND AROUND THE SITE ARE TO REMAIN OPEN TO THE PUBLIC AND RESIDENTS AND FREE OF DEBRIS AND OBSTRUCTIONS. THE CONTRACTOR SHALL PROVIDE OVERHEAD
PROTECTION (NETTING AND PEDESTRIAN BRIDGING) FOR HIS SCAFFOLDING.
5. PROTECT SITE FEATURES, WALKS, TREES AND OTHER PLANTINGS FROM DAMAGE. PROVIDE WRITTEN
DESCRIPTION OF PROTECTIVE MEASURES TO THE COR FOR APPROVAL.
6. THE HOUSE AT 408 LOCUST STREET IS USED AS A PRIVATE RESIDENCE FOR PARK EMPLOYEES. AS SUCH
THE INTERIOR OF THE BUILDING IS NOT ACCESSIBLE TO THE CONTRACTOR UNLESS PRIOR
ARRANGEMENTS HAVE BEEN MADE THROUGH THE PARK AT LEAST 48 HOURS IN ADVANCE. THE
CONTRACTOR AND HIS PERSONNEL SHALL RESPECT THE PRIVACY OF THE RESIDENTS. MINIMIZE
DISTURBANCES TO THE RESIDENTS BY SCHEDULING LOUDER WORK AFTER 9 AM.
7. SMOKING AND/OR VAPING IS PROHIBITED ANYWHERE ON THE SITE EXCEPT IN DESIGNATED SMOKING
AREA(S) ESTABLISHED AT THE CONTRACTOR'S REQUEST. IF ESTABLISHED IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO KEEP THE AREA CLEAN AND FREE OF TRASH.
8. THESE DRAWINGS HAVE BEEN PREPARED BASED ON EXISTING DRAWINGS AND SELECT FIELD
MEASUREMENTS AND ARE NOT TO BE SCALED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES
PRIOR TO BEGINNING THE WORK.
9. GENERAL CONTRACTOR (G.C.) SHALL PROTECT EXISTING ASSEMBLIES, MATERIALS, FINISHES AND WALLS TO REMAIN FOR DURATION OF WORK. ANY DAMAGES INCURRED DURING CONSTRUCTION SHALL BE
REPAIRED/RESTORED AT THE CONTRACTORS EXPENSE.
10. COORDINATE ALL SELECTIVE REMOVAL WORK WITH THE EXTENT OF ALL NEW WORK..
11. ALL REMOVALS AND DEMOLITION SHALL BE DONE IN A NEAT AND WORKMAN LIKE MANNER.
12. THE WORD 'REMOVE', FOR THE PURPOSES OF THE DEMOLITION DRAWINGS, MEANS TO REMOVE ITEMS
FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFFSITE, UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED. 'REMOVE AND SALVAGE' MEANS TO DETACH ITEMS FROM EXISTING CONSTRUCTION AND DELIVER THEM TO CONTRACTING OFFICER AT LOCATIONS IDENTIFIED BY THE CONTRACTING OFFICER. 'REMOVE AND REINSTALL' MEANS TO DETACH ITEMS FROM CONSTRUCTION, PREPARE FOR REUSE, AND REINSTALL THEM WHERE INDICATED. SEE SPECIFIC
REFERENCED NOTES RELATED TO EACH CONDITION.
13. DASHED LINES INDICATE APPROXIMATE OUTLINE OF ROOFING AREAS TO BE DEMOLISHED. THE SCOPE OF
WORK AT THESE AREAS IS TO REMOVE ROOFING MATERIAL AND UNDERLAYMENTS DOWN TO WOOD
DECKING, REMOVE METAL AND OTHER FLASHINGS AND COUNTER FLASHINGS, REMOVE FASTENERS, CAULKING AND OTHER ACCESSORIES RELATING TO INSTALLATION OF EXISTING ROOFING.
14. EXISTING WOOD ROOF DECKING IS TO REMAIN, EXCEPT WHERE NOTED TO BE REMOVED. IT IS ANTICIPATED THAT SOME DECKING NOT SHOWN TO BE REMOVED IS DETERIORATED AND WILL REQUIRE
REPLACEMENT. SEE ROOFING DRAWINGS AND SPECIFICATIONS FOR QUANTITY OF REPLACEMENT
DECKING; REMOVE EXISTING DECKING ACCORDINGLY.
15. THE CONTRACTOR SHALL SCHEDULE REMOVAL WORK TO ALLOW CONTRACTING OFFICER TO INSPECT
AREAS OF DETERIORATED WOOD DECKING, FRAMING, CORNICES AND SOFFITS.
16. IT IS NOT THE INTENT OF THE DEMOLITION DRAWING TO SHOW ALL MATERIAL THAT MIGHT NEED TO BE REMOVED (WHETHER REINSTALLED OR NOT) AS PART OF THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REMOVE AND REINSTALL MATERIAL AS NECESSARY FOR THE WORK ON ADJACENT
COMPONENTS OR TO ACCESS AREAS OF THE ROOF FOR INSTALLATION OF NEW WORK. THIS IS
CONSIDERED TO BE PART OF THE CONTRACTOR'S MEANS AND METHODS. ADDITIONALLY, ANY REMOVALS THAT ARE REQUIRED AS PART OF CUTTING AND PATCHING ARE TO BE INCLUDED, EVEN IF NOT
SPECIFICALLY IDENTIFIED ON THE DRAWINGS.
17. ALL PAINTED SURFACES ARE ASSUMED TO BE COATED WITH LEAD BASED PAINT AND ALL WORK
IMPACTING THESE SURFACES SHALL BE COMPLETED IN ACCORDANCE WITH OSHA'S LEAD IN
CONSTRUCTION STANDARD (29 CFR 1926.62). aT HIS OPION THE CONTRACTOR MAY TEST THE PAINTS FOR LEAD AND IF FOUND TO BE BELOW ACTION LEVELS ADJUST HIS MEANS AND METHODS ACCORDINGLY.
CAREFULLY CUT BACK TO SOUND
WOOD TO REMOVE EXISTING
DETERIORATED WD. CORNICE TRIM,
MOLDINGS, MODILLION BLOCKS AND
WD. BLOCKING. MAKE CUTS NEAT AND
TRUE, READY TO RECEIVE NEW
MOLDINGS. USE SCARF OR BEVELED
CUTS FOR RUNNING TRIM OR
EXPOSED BOARDS.
INSTALL TEMPORARY POLYVINYL
CHLORIDE FLEXIBLE PIPE AT
DOWNSPOUT LOCATION. CONNECT
PIPE FROM CORNICE OUTLET TO
GRADE DRAIN. FLEXIBLE PIPE SHALL
REMAIN INSTALLED FOR DOWNSPOUT
REMOVAL.
CAREFULLY REMOVE EXISTING
CHIMNEY CAP. DO NOT DAMAGE
EXISTING MASONRY CAP OR FLUES.
LEAD PAINT, SCRAPE, CLEAN & PREP
FOR NEW PAINT, PROPERLY CONTAIN
AND DISPOSE OF PAINT DEBRIS. LEAD
ABATEMENT/CONTROL PLAN
REQUIRED.
LINE OF EXISTING ADJACENT
BUILDING MINOR MASONRY REPAIRS
REQUIRED, QUANTITIES OF WORK ARE
PART OF BASIS OF BID .
D1
SCALE: 1/4" = 1'-0"
NORTH ELEVATION
0' 2'1' 3' 4' 5' 10'
DORMER DETAIL
NOT TO SCALE
D1
D1
D1
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
9/25/10 rev. 10/28/20
D1
408 LOCUST STREET
NORTH ELEVATION
DEMO DRAWING
INDEPENDENCE NATIONAL HISTORICAL PARK
xxx xxx,xxx
CORNICE DETAIL
NOT TO SCALE
D1
NORTH CHIMNEY
NOT TO SCALE
D1
REMOVE EXISTING STEP FLASHING
FROM CHIMNEY AND CLEAN REGLETS
TO RECEIVE NEW STEPPED FLASHING.
REMOVE COUNTER AND CLEAN
REGLET TO RECEIVE NEW COUNTER
FLASHING, TYP. WHERE FOUND.
REMOVE EXISTING STANDING SEAM
METAL ROOF
CAREFULLY REMOVE DORMER CHEEK
BOARDS AS REQUIRED TO ALLOW FOR
INSTALLATION OF NEW DORMER
FLASHING
REMOVE EXISTING WOOD SASH FOR
RESTORATION. INSTALL TEMPORARY
PLYWOOD PANEL AT OPENING FOR
DURATION OF WINDOW RESTORATION
REMOVE EXISTING STANDING SEAM
METAL ROOF
CAREFULLY REMOVE EXISTING SPARK
ARRESTOR AND CEMENT CHIMNEY
CAP. DO NOT DAMAGE EXISTING
MASONRY .OR FLUES.
REMOVE EXISTING
DOWNSPOUT
EXISTING 410 LOCUST STREET PARTY
WALL. CUT BACK FAILED OR MISSING
MORTAR JOINTS TO PREPARE FOR
RE-POINTING.
FLASHING WORK
AT PARTY WALL
NOT TO SCALE
D1
CAREFULLY REMOVE METAL
COUNTERFLASHING AND STEPPED
FLASHING FULL SLOPE OF ROOF.
PROVIDE NEW METAL STEPPED AND
COUNTERFLASHING
REMOVE STANDING SEAM METAL
ROOF
EAST CORNICE TERMINATION
NOT TO SCALE
D1
REMOVE EXISTING POLE
GUTTER/ROOF
TERMINATION. PROVIDE
NEW METAL TERMINATION.
USE EXISTING AS PATTERN
FOR FABRICATION OF NEW
CUT BACK DETERIORATED WD. TRIM
TO SOUND MATERIAL. MAKE CUTS
NEAT AND TRUE READY TO RECEIVE
WD. PATCH. USE SCARF OR BEVELED
CUTS FOR RUNNING TRIM AND FINISH
BOARDS. TYP WHERE FOUND.
REMOVE DETERIORATED DORMER
CHEEK BOARDS IN THEIR ENTIRETY
AS REQUIRED.
CUT OUT FAILED OR UNBONDED
MORTAR JOINTS TO A MIN 34" DEPTH
AND MAKE READY TO RECEIVE NEW
MORTAR. BASIS OF BID QUANTIES
APPLY TO THIS WORK.
AFTER REMOVAL OF THE STANDING
SEAM METAL ROOF INSPECT POLE
GUTTER SUBSTRATE AND ROOF DECK.
REMOVE DETERIORATED SECTIONS AS
REQUIRED. SEE BASIS OF BID.
LEAD PAINT, SCRAPE, CLEAN
& PREP FOR NEW PAINT,
PROPERLY CONTAIN AND
DISPOSE OF PAINT DEBRIS.
LEAD ABATEMENT/CONTROL
PLAN REQUIRED.
INSPECT EXISTING CORNICE
FOR DETERIORATED,
DAMAGED, ROTTED OR LOOSE
WOOD. LEAVE IN PLACE WOOD
THAT CAN BE REPAIRED BY
GLUING OR FILLING CRACKS
AND CHECKS. CUT OUT WOOD
DAMAGED BEYOND REPAIR.
CUTS SHALL BE FROM
BEARING/ATTACHMENT POINT
TO BEARING/ATTACHMENT
POINT.
CUT BACK DETERIORATED TRIM TO
SOUND WOOD.
REMOVE EXISTING METAL
WALL CAP FLASHING
INSPECT RAKE BOARDS
AFTER REMOVAL OF CAP
FLASHING OR ROOF, REPORT
ON CONDITION TO COR.
BASIS OF BID APPLIES TO
REPAIRS.
CAREFULLY REMOVE EXISTING
CAP FLASHING & NAILER TO
MINIMIZE DAMAGE TO EXISTING
MASONRY PARAPET WALL.
INSPECT MASONRY AND REPORT
CONDITION TO COR. REQUIRED
MASONRY REPAIRS ARE PART OF
BASIS OF BID QUANTITIES.
INSPECT EXISTING FLASHING
AND REPORT CONDITION TO COR.
CLEAN EXISTING CAULK/SEALANT
FROM REGLETS AND PREPARE
METAL TO RECEIVE NEW CAULK
AND PAINT.
D2
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
0' 2'1' 3' 4' 5' 10'
SHED ROOF DETAIL
NOT TO SCALE
D2
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
9/25/10 rev. 12/10/20
D2
408 LOCUST STREET
SOUTH ELEVATION
DEMO DRAWING
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
SOUTH ROOF PARAPET
NOT TO SCALE
D2
EXISTING PARAPET DETAIL
NOT TO SCALE
D2
CAREFULLY REMOVE EXISTING
FLAT SEAM METAL ROOF
INCLUDING ALL CLIPS, NAILS AND
CANTS. INSPECT DECK AND
REPORT CONDITION TO COR.
REQUIRED REPAIRS ARE PART OF
BASIS OF BID QUANTITIES.
RAKE OUT AND REPOINT
DETERIORATED MORTAR
JOINTS AT CHIMNEY
INSPECT EXISTING SHEET METAL
POLE GUTTER AND METAL ROOF
INCLUDING EDGE CONDITIONS.
REPORT CONDITION TO COR.
PREPARE METAL SURFACES TO
RECEIVE NEW PAINT.
REMOVE ALL LOOSE, FAILED
PAINT. PREP TO PREPARE
FOR NEW FINISHES.
REMOVE METAL
DOWNSPOUT
REMOVE EXISTING
STANDING SEAM METAL
ROOF AND FLASHINGS.
INSPECT ROOF DECK AND
REPORT CONDITION TO
COR.
REMOVE EXISTING
METAL DOWNSPOUT
INSPECT EXISTING SHEET
METAL POLE GUTTER AND
SHEET METAL ROOF. SEE
DETAIL 4/D2.
REMOVE EXISTING
METAL DOWNSPOUT
CAREFULLY REMOVE EXISTING
CEMENT CHIMNEY CAP. DO
NOT DAMAGE EXISTING
MASONRY CAP BELOW
SEE DETAIL 2/D2 & 3/D2 FOR
WORK AT WALL CAP
CUT BACK FAILED MASONRY
JOINTS TO MAKE READY FOR
RE-POINTING.
REMOVE ALL LOOSE, FAILED
PAINT. PREP TO PREPARE
FOR NEW FINISHES. TYP.
ALL SURFACES OF AWNING
ROOF.
INSPECT EXISTING RAKE
BOARDS AND REPORT
CONDITION TO COR.
REPAIRS ARE PART OF
BASIS OF BID QUANTITIES.
PREP FOR NEW PAINT.
EXISTING SHED ROOF
NOT TO SCALE
D2
INSPECT EXISTING SHEET METAL ROOF
INCLUDING EDGE CONDITIONS AND
FLASHING. REPORT CONDITION TO COR.
PREPARE METAL SURFACES TO RECEIVE
NEW PAINT. REMOVE EXISTING CAULK @
REGLET AND MAKE READY TO RECIEVE
NEW CAULK.
REMOVE ALL LOOSE, FAILED PAINT.
PREP TO PREPARE FOR NEW FINISHES.
TYP. @ ALL WOOD SURFACES
INCLUDING UNDERSIDE OF SHED ROOF.
0' 2'1' 3' 4' 5' 10'
REMOVE FLAT
SEAM METAL ROOF
AT DORMER. SEE
4/D1 FOR REMOVAL
WORK.
CAREFULLY REMOVE
EXISTING CEMENT
CHIMNEY CAP. DO NOT
DAMAGE EXISTING
MASONRY CAP BELOW
AND FLUES
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
9/25/10 rev. 12/10/20
D3
408 LOCUST STREET
WEST ELEVATION
DEMO DRAWING
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
D3
SCALE: 1/4" = 1'-0"
WEST ELEVATION
REMOVE EXISTING
STANDING SEAM METAL
PARAPET CAP
REMOVE EXISTING
SCUPPER, CONDUCTOR
HEAD AND DOWNSPOUT.
INSTALL TEMPORARY
POLYVINYL CHLORIDE
FLEXIBLE PIPE AT
DOWNSPOUT LOCATION.
CONNECT FROM ROOF TO
GRADE DRAIN FOR
DURATION OF
ROOF/DOWNSPOUT WORK.
REMOVE EXISTING
PARAPET METAL ROOF
PARTY WALL
NOT TO SCALE
D3
EXISTING SCUPPER
NOT TO SCALE
D3
SERVICE WING ROOF
NOT TO SCALE
D3
WEST STANDING
SEAM METAL ROOF
NOT TO SCALE
D3
AFTER REMOVAL OF ROOF
REMOVE OUTER TRIM PIECE
REMOVE EXISTING
STANDING SEAM METAL
ROOF AND FLASHING.
REPORT CONDITION OF
WOOD DECK TO COR.
SCRAPE, SAND, SMOOTH,
AND PAINT WOOD TRIM
REMOVE EXISTING
STANDING SEAM METAL
ROOF
REMOVE EXISTING METAL
DOWNSPOUT. INSTALL
TEMPORARY POLYVINYL
CHLORIDE FLEXIBLE PIPE AT
DOWNSPOUT LOCATION.
CONNECT FROM ROOF TO
GRADE DRAIN FOR DURATION
OF WORK.
REMOVE LOOSE FAILING
PAINT FINISHES FROM
WOOD TRIM, WASH AND
MAKE READY TO PAINT.
TYP. FOR ALL WOOD TRIM
NOT SLATED FOR
REMOVAL.
EXISTING WOOD TRIM TO
REMAIN. LEAD PAINT
ABATE, SAND, SMOOTH,
AND PAINT
CHIMNEY FLASHING WORK
NOT TO SCALE
D3
REMOVE EXISTING
CHIMNEY CAP FLASHING
LEAD PAINT ABATE STEEL
SUPPORTS. REMOVE ALL
RUST. PRIME AND PAINT
REMOVE METAL
COUNTERFLASHING AND
STEPPED FLASHING AT
CHIMNEY
REMOVE METAL
COUNTERFLASHING
REMOVE EXISTING
VENT PIPE FLASHING
CAREFULLY REMOVE
EXISTING CEMENT
CHIMNEY CAP. DO NOT
DAMAGE EXISTING
MASONRY CAP BELOW
AND FLUES
D3
6REMOVE EXISTING
STANDING SEAM METAL
ROOF. SEE 4/D3 FOR
REMOVAL WORK
REMOVE EXISTING VENTS.
D2
APPROXIMATE
AREA OF MASONRY
REPAIRS. RAKE OUT
AND REPOINT
DETERIORATED
MORTAR JOINTS AT
PARTY WALL
D3
REMOVE EXISTING METAL
DOWNSPOUT.
REMOVE EXISTING
METAL DOWNSPOUT.
INSPECT THE EXISTING SHEET
METAL POLE GUTTER AND
STANDING SEAM METAL ROOF AND
REPORT CONDITION TO COR.
SEE 4/D2 FOR THE EXTENT OF THE
REQUIRED WORK.
D3
CAREFULLY REMOVE
EXISTING ROTTED DORMER
LOWER CHEEK BOARD TO
ALLOW REMOVAL AND
INSTALLATION OF NEW
DORMER FLASHING
RAKE OUT AND REPOINT
DETERIORATED MORTAR
JOINTS AT PARTY WALL.
BASIS OF BID
QUANTITIES APPLY TO
THIS WORK.
D4
SCALE: 1/4" = 1'-0"
ROOF PLAN
SERVICE WING ROOF
NOT TO SCALE
D4
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
09/25/10 Rev. 12/10/20
D4
408 LOCUST STREET
ROOF PLAN
DEMO DRAWING
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
NORTH CHIMNEY
NOT TO SCALE
D4
NORTH CHIMNEY CAP
NOT TO SCALE
D4
SOUTH CHIMNEY
NOT TO SCALE
D4
EXISTING FLUES TO REMAIN
REMOVE EXISTING MORTAR
CAP
REMOVE EXISTING
SPARK ARRESTER/
METAL CAP.
SALVAGE FOR
REUSE.
SERVICE WING ROOF
NOT TO SCALE
D4
SEE SHEET A3 FOR
WORK AT MASONRY
PARTY WALL
REMOVE METAL CAP
FLASHING AND
COUNTERFLASHING
REMOVE EXISTING
ROOF
REMOVE PARAPET
FLASHING
REMOVE DOWNSPOUT.
SEE SHEET D3 FOR
ADDITIONAL WORK
REMOVE EXISTING PARTY WALL COUNTER
FLASHING
REMOVE EXISTING VENT. PROVIDE NEW
VENT OF APPROXIMATELY THE SAME
SIZE. MODIFY CURB AND/OR ROOF DECK
AS REQUIRED FOR NEW VENT, TYP.
REMOVE EXISTING SHEET METAL POLE
GUTTER AND SHEET METAL ROOF INCLUDING
ALL FLASHING, NAILS, CLIPS AND OTHER
ACCESSORIES. INSPECT DECK AND REPORT
ON CONDITION. REPAIRS TO DECK ARE PART
OF BASIS OF BID QUANTIES.
REMOVE EXISTING SHEET
METAL POLE GUTTER AND
SHEET METAL ROOF. SEE 6/D4
FOR ADDITIONAL INFORMATION
ON DEMO WORK AT SERVICE
WING ROOF.
SEE 3/D1 FOR WORK AT CHIMNEY
ROOF INTERLACE. SEE 3/D4 FOR
WORK AT CHIMNEY.
SEE 2/D4 AND 4/D4 FOR WORK
AT CHIMNEY
REMOVE EXISTING VENTS.
PROVIDE NEW VENTS OF
APPROXIMATELY THE SAME SIZE.
MODIFY CURB AND/OR DECK AS
REQUIRED FOR NEW VENTS.
REMOVE EXISTING
PIPE
REMOVE EXISTING ROOF
TO WOOD DECK.
0' 2'1' 3' 4' 5' 10'
INSPECT EXISTING MASONRY.
REPORT CONDITION TO COR.
MASONRY REPAIRS ARE PART
OF BASIS OF BID.
INSPECT EXISTING
MASONRY. REPORT
CONDITION TO COR.
MASONRY REPAIRS
ARE PART OF BASIS
OF BID QUANTITIES.
INSPECT EXISTING SHED
ROOFS. REPORT CONDITION
TO COR. PREP FOR PAINTING.
REMOVE EXISTING ROOF TO
WOOD DECK. INSPECT ROOF
DECK AND REPORT CONDITION
TO COR. SEE SHT. D1 FOR
ADDITIONAL INFORMATION.
REPAIRS TO DECK ARE PART OF
THE BASIS OF BID QUANTITIES.
INSPECT EXISTING
MASONRY. REPORT
CONDITION TO COR.
MASONRY REPAIRS
ARE PART OF BASIS
OF BID QUANTITIES.
A1
SCALE: 1/4" = 1'-0"
NORTH ELEVATION
0' 2'1' 3' 4' 5' 10'
JCT/PFS
WC
9/25/10 Rev. 12/10/20
A1
408 LOCUST STREET
NORTH ELEVATION
NEW CONSTRUCTION DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
NORTH DORMER DETAIL
NOT TO SCALE
A1
INSPECT ALL FINISH WOOD
PARTS OF DORMER AND
REPORT CONDITION TO
COR. REPAIRS ARE PART
OF BASIS OF BID. PREP,
PRIME AND PAINT, TYP.
A1
A1
A1
NEW FLAT SEAM
METAL ROOF. SEE 4/A5
FOR DETAILS
DORMER DRIP EDGE DETAIL
NOT TO SCALE
A1
AFTER REPAIRS PREP,
PRIME AND PAINT ALL
WOOD SURFACES. NEW
WOOD TO BE PRIMED
ON ALL SURFACES.
DASHED LINE
INDICATES METAL
FLASHING BEHIND
WOOD SIDING
REPLACE DAMAGED
WOOD SIDING AT
DORMER CHEEK WALL.
MATCH EXISTING SIZE,
SHAPE AND PROFILE
FLAT SEAM
METAL ROOF
DORMER ROOF
BOARDS
SELF ADHERING
WATERPROOFING
W/ SLIP SHEET
OVER.
CONT. METAL
CLEATS NAIL @
TOP 8" O.C.& ON
SIDES @ 12"O.C.
CONTINUOS
METAL DRIP
DORMER GABLE EDGE DETAIL
NOT TO SCALE
A1
2" WIDE 16 OZ
METAL CLEATS
AT 2'-0" O.C.
SNAP ROOFING
OVER
CONTINUOUS
CLEAT
1/2" DRIP
SELF ADHERING
WATERPROOFING
WITH SLIP SHEET
OVER.
FLAT SEAM METAL
ROOF
DORMER ROOF BOARD
TYPICAL LOCKED
AND SOLDERED SEAM DETAIL
NOT TO SCALE
A1
STANDING SEAM
METAL ROOF
2" WIDE CLEAT AT
12" O.C.
3/4" LOCKED AND
SOLDERED SEAM
2" WIDE CONTINUOUS
CLEAT AT 12" O.C.
BEND METAL BACK
OVER NAIL HEADS
REGLET DETAIL
NOT TO SCALE
A1
SAW CUT REGLET 1"
DEEP TO FOLLOW
EXISTING MASONRY
JOINTS
CONTINUOUS
BACKER ROD AND
SEALANT
LEAD WEDGES
1/4" HOOK DAM
16 OZ METAL BASE
AND/OR CAP FLASHING
DORMER RIDGE DETAIL
NOT TO SCALE
A1
FLAT SEAM RIDGE
A2
A1
A5
A5
SNAP ROOFING OVER
CONTINUOUS CLEAT
WOOD ROOF DECK
SELF ADHERING
WATERPROOFING WITH SLIP
SHEET OVER.
POLE GUTTER SUBSTRATE
TREATED 2 X 6 BEVEL CUT
TO SLOPE.
CONTINUOUS CLEAT
BEND FLASHING
BACK OVER
NAIL HEADS
FLASHING DETAIL
FOR POLE GUTTER
NOT TO SCALE
A1
EXISTING WOOD CORNICE
EXISTING BRICK WALL
FLAT SEAM METAL
ROOF
GENERAL WORK AT WINDOW SASH
1. REMOVE SASH FOR REPAIRS IN
SHOP.
2. REMOVE ALL GLAZING PUTTY
FROM SASH SALVAGE GLASS
FOR REUSE.
3. LEAD PAINT ABATE WOOD SASH
4. LIGHTLY SAND FLAT SURFACES
OF WOOD SASH SMOOTH.
5. CLEAN WOOD SASH WITH
LINSEED OIL.
6. REINSTALL GLASS WITH NEW
GLAZING PUTTY.
7. SHOP PRIME SASH.
8. APPLY FINISH COAT.
9. COORDINATE SASH
INSTALLATION WITH SILL REPAIR
OR REPLACEMENT AND SILL
FLASHING WORK.
D1
A1
REMOVE FAILING
UNBONDED PAINT FROM
CORNICE, PREP AND
PAINT WOOD CORNICE
STANDING
SEAM METAL
ROOF
REPAIR WOOD CORNICE,
REPLACE DAMAGED
ROTTED WOOD. INSPECT
OUTRIGGERS AND
REPORT CONDITION TO
COR. PAINT CORNICE.
SEE BASIS OF BID.
NEW DOWNSPOUT.
COORDINATE DOWNSPOUT
INSTALLATION WITH
CORNICE WORK.
GENERAL NOTES
1. PROVIDE TEMPORARY ROOF PROTECTION FOR
DURATION OF WORK.
2. PAINT ALL METAL ROOFS, TRIMS AND FLASHINGS.
3. PAINT ALL METAL DOWNSPOUTS.
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
BEND METAL BACK
OVER NAIL HEADS
CONTINUOUS BEAD
OF SEAM SEALANT
A3
NEW CEMENT CAP SLOPE 2" TO EDGE.
COAT WITH SILANE WATERPROOFING
AFTER CURING.
EXISTING TERRA COTTA FLUE LINER.
CONTINUOUS BEAD OF
SEAM SEALANT
A3
REPLACE
DAMAGED/
ROTTED WOOD
WITH NEW
WOOD. MATCH
SIZE, PROFILE,
SHAPE AND
SPECIES WITH
EXISTING
MATERIAL. USE
SCARF JOINT TO
ATTACH NEW TO
OLD.
NO WORK BELOW CORNICE
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
9/25/10 Rev. 12/10/20
A2
408 LOCUST STREET
SOUTH ELEVATION
NEW CONSTRUCTION DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
0' 2'1' 3' 4' 5' 10'
POLE GUTTER DETAIL
NOT TO SCALE
A2
REPAIR EXISTING
MOLDING AS REQUIRED.
PREP AND PAINT.
CONTINUOUS
METAL CLEAT.
SOLDER TO
GUTTER.
STANDING SEAM
METAL ROOF
PLYWOOD ROOF DECK
A2
SELF ADHERING
WATERPROOFING
AND SLIP SHEET
PARAPET FLASHING DETAIL
NOT TO SCALE
A2
METAL CAP FLASHING
NEW WD. BLOCKING TAPER CUT TOP
EPDM MEMBRANE TERMINATED OVER
TOP OF WALL
CONTINUOUS TERMINATION BAR
EPDM TAPE
SEALANT
WOOD CANT
REINFORCED EPDM MEMBRANE
PRESSURE SEALANT FLASHING
EPDM ROOF
BONDING AGENT
GYP. BOARD UNDERLAYMENT
ADHERED
NEW PLYWOOD SET ON NEW
FRAMING TO CREATE VALLEY
AS SHOWN.
STEPPED FLASHING DETAIL
NOT TO SCALE
A2
16 OZ METAL STEPPED
CAP FLASHING. ADJUST
WIDTH TO FOLLOW
EXISTING REGLET. FIELD
VERIFY EXACT LOCATIONS
16 OZ METAL BASE
FLASHING
SELF ADHERING
WATERPROOFING AND SLIP
SHEET
EXISTING WOOD ROOF
DECK
ROOF EDGE DETAIL
NOT TO SCALE
A2
METAL DRIP
CONTINUOUS 2"
METAL CLEAT
SNAP ROOFING
OVER
CONTINUOUS
CLEAT. 1/2" HEM.
NEW WOOD
TRIM, PRIME AND
PAINT.
EXISTING BRICK
WALL
SELF ADHERING
WATERPROOFING
AND SLIP SHEET
STANDING SEAM
METAL ROOF
ROOF DECK
NEW STANDING
SEAM METAL
ROOF
LEAD PAINT
ABATE, SAND
SMOOTH, AND
PAINT WOOD
TRIM AND
SIDING
NEW WOOD TRIM , MATCH
EXISTING. PRIME AND PAINT. SALVAGE AND
RESET SHEET METAL
CAP AND
SCREENING AT FLUE
PROVIDE NEW MORTAR CAP
HATCHED AREA
INDICATES
APPROXIMATE
AREA OF
DETERIORATED
MORTAR JOINTS.
RAKE OUT AND
REPOINT MORTAR
JOINTS.
SCRAPE LOOSE
FAILING PAINT, WAS
AND PAINT WOOD
TRIM AND SIDING.
GENERAL NOTES
1. PROVIDE TEMPORARY
ROOF PROTECTION FOR
DURATION OF WORK.
2. PAINT ALL METAL ROOFS,
TRIMS AND FLASHING.
3. PAINT ALL METAL
DOWNSPOUTS.
4. NO WORK BELOW
CORNICE OR RAKE
BOARDS UNLESS NOTED.
5. NOTE EXISTING PAINT
ASSUMED TO BE LEAD
PAINT. FOLLOW LEAD
PAINT REGULATIONS.
A2
A2
A2
CONT. COPPER CLEAT
CONT. COPPER
CLEAT/DRIP EDGE
PAINTED 12" X 3-1/2"
WD. SPACER @ 12"
O.C. INSTALL 12" X 1"
@ TOP OF GAP
BETWEEN SPACERS.
BRONZE INSECT
SCREEN. WRAP
WOOD SPACER
STAPLE AS SHOWN
SCRAPE/PREP AND
PAINT WOOD TRIM.
4" X 8" 18" STAINLESS STL. ANGLE
2" WIDE ATTACH TO DECK @ 32"
O.C. FASTEN TO DECK AND POLE
GUTTER W/ #10 SS SCREWS
CONT. SEAM SEALANT
REPAIR/REPOINT
INSIDE FACE OF
PARAPET WALL
AFTER ROOF
DEMOLITION
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
9/25/10 Rev.12/10/20
A3
408 LOCUST STREET
WEST ELEVATION
NEW CONSTRUCTION DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
CHIMNEY FLASHING DETAIL
NOT TO SCALE
A3
EXISTING
BRICK CHIMNEY
METAL CAP
FLASHING SET IN
EXISTING REGLETS.
METAL CLEAT AT
1'-0" O.C.+/-.
ATTACH CLIPS
W/FASTENERS SET
IN EXPANSION
ANCHORS SET IN
MORTAR JOINTS.
METAL COPPER
STRIP SOLDER TO
TERNE COATED
COPPER ROOF
METAL ROOF
SLIP SHEET AND
SELF ADHERING
WATERPROOFING
METAL BASE
FLASHING 0' 2'1' 3' 4' 5' 10'
A3
SCALE: 1/4" = 1'-0"
WEST ELEVATION
SCUPPER DETAIL
NOT TO SCALE
A3
SHEET METAL
SLEEVE
LAP SEALANT
DRAIN GUARD
EPDM MEMBRANE
FLASHING
EPDM ROOFING
GYP. BOARD
PLYWOOD
2" WOOD
BLOCKING
EXISTING WALL
SHEET METAL
PARAPET CAP,
SEE DETAIL 2/A2
SHEET METAL
CONDUCTOR
HEAD
SOLDERED
CONNECTION
3" METAL DOWNSPOUT.
FIELD VERIFY
DOWNSPOUT DIMENSION
PITCH DETAIL
NOT TO SCALE
A3
2" METAL CLEAT
AT 2" O.C.
SOLDERED TO
STANDING SEAM
ROOF
ROSIN PAPER.
LAP MIN. 8" OVER
ROSIN PAPER ON
STEPPER ROOF
EXISTING ROOF
DECK
2" METAL CLEAT
AT 2" O.C.
ANCHORED TO
EXISTING ROOF
DECK
EXISTING ROOF
DECK
REGLET DETAIL
NOT TO SCALE
A3
SAW CUT REGLET 1"
DEEP TO FOLLOW
EXISTING MASONRY
JOINT
PACK JOINT WITH
BACKER ROD AND
SEALANT
METAL CAP
TERMINATION BAR
CONTINUOUS WOOD CANT
STRIP
SEALANT
REINFORCED EPDM
MEMBRANE
PRESSURE SEALANT
FLASHING
EPDM
BONDING AGENT
GYP. BOARD
UNDERLAYMENT ADHERE
NEW PLYWOOD DECK
ON NEW FRAMING BUILT
ON EXISTING DECK. MIN.
4" SLOPE TO NEW
VALLEY.
A1
A1
LEAD PAINT ABATE,
SAND SMOOTH, AND
PAINT DORMER CHEEK
WALLS
NEW FLAT SEAM
METAL ROOF
A3
A3
A3
REMOVE THE EXISTING MORTAR CAP, REMOVE DETERIORATED AND FAILED
MORTAR JOINTS AND POINT TOP OF WALL. APPLY NEW MORTAR CAP AND APPLY
SILOXANE WATER REPELLANT AFTER MORTAR CAP HAS CURED, TYPICAL AT ALL
CHIMNEY TOPS AND THE ENTIRE LENGTH OF THE EAST WALL PARAPET
NEW ROOF VENT
AND FLASHING AT
EXISTING OPENING
A2
A2
A3
A3
A3
A2
A3
NEW METAL
DOWNSPOUT
NEW METAL
DOWNSPOUT
NEW STANDING
SEAM METAL ROOF
EXISTING FLAT
SEAM METAL ROOF.
PREP AND PAINT
PREP AND PAINT
PARAPET WOOD
TRIM
ROSIN PAPER
RAKE OUT AND
REPOINT
DETERIORATED
MORTAR JOINTS
GENERAL NOTES
1. PROVIDE TEMPORARY ROOF PROTECTION FOR DURATION OF WORK.
2. PAINT ALL METAL ROOFS, TRIMS AND FLASHINGS.
3. PAINT ALL METAL DOWNSPOUTS.
4. PREP AND PAINT ALL EXPOSED WOOD ASSOCIATED WITH EAVES, CORNICES AND
RAKES. NOTE EXISTING PAINT ASSUMED TO BE LEAD PAINT.
5.
A2
INSPECT EXISTING CHIMNEY SUPPORT
& REPORT CONDITION TO COR. NO
WORK REQUIRED.
A4
SCALE: 1/4" = 1'-0"
ROOF PLAN
0' 2'1' 3' 4' 5' 10'
FLASHING AT CHIMNEY
NOT TO SCALE
A4
DRAWN BY:
TECH. REVIEW:
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
JCT/PFS
WC
9/25/10 Rev. 12/10/20
A4
408 LOCUST STREET
ROOF PLAN
NEW CONSTRUCTION DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
FLAT SEAM ROOF
TYPICAL DETAIL (OPTION # 3)
NOT TO SCALE
A4
A4
GENERAL NOTES FOR 408 LOCUST STREET ROOF WORK
1. ALL MATERIALS NOTED ON THE DRAWINGS ARE TO BE
NEW UNLESS OTHERWISE NOTED AS EXISTING.
2. THESE DRAWINGS HAVE BEEN PREPARED BASED ON
EXISTING DRAWINGS AND SELECT FIELD MEASUREMENTS
AND ARE NOT TO BE SCALED WHERE PRECISE
DIMENSIONS ARE REQUIRED. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY ALL EXISTING
CONDITIONS AND NOTIFY THE CONTRACTING OFFICER OF
ANY DISCREPANCIES PRIOR TO BEGINNING THE WORK.
GENERAL NOTES ON ROOFING
1. FOR ALL LOCATIONS WHERE ROOF SHEATHING NEEDS TO
BE REPLACED THE TOP FACE OF THE NEW SHEATHING
MUST BE AT THE SAME LEVEL AS EXISTING.
2. INCLUDE A TOTAL OF 120 SQUARE FEET OF
REPLACEMENT OF WOOD SHEATHING AT AREAS OF
DETERIORATED WOOD SHEATHING. THIS INCLUDES
AREAS WHERE THE DRAWINGS SHOW NEW SHEATHING
FOR REPAIRS AND SOME WHERE IT IS NOT SHOWN BUT
WILL BE REQUIRED. NEW DECK FOR EPDM IS NOT
INCLUDED IN THIS QUANTITY.
3. PREPARE ALL EXISTING SURFACES TO REMAIN THAT WILL
RECEIVE NEW FINISHES, INCLUDING BUT NOT LIMITED TO
REMOVING LOOSE FAILED PAINT, CLEANING ALL
SURFACES, PATCHING HOLES TO MATCH, ETC.
4. ALL PAINTED SURFACES ARE ASSUMED TO BE COATED
WITH LEAD BASED PAINT AND ALL WORK IMPACTING
THESE SURFACES SHALL BE COMPLETED IN
ACCORDANCE WITH OSHA'S LEAD IN CONSTRUCTION
STANDARD (29 CFR 1926.62).
STANDING SEAM
METAL ROOF
CLEAT DETAIL
INSTALL TWO CLEATS PER
LONG SIDE OF PAN AND
ONE CLEAT PER SHORT
SIDE OF PAN
TWO RING SHANK
COPPER NAILS PER
CLEAT
BEND FLASHING
BACK OVER NAIL
HEADS
FLAT SHEET: 18"X24" MAX.
LINE OF FOLD
CORNERS
NOTCHED
OVER FOLD
UNDER FOLD
TURNED
EDGES
FOLDED SHEET
STANDING SEAM
SHEET METAL
ROOF
A1
A2
A3
SIM.
A2
STANDING SEAM
SHEET METAL ROOF
P
ITC
H
EPDM ROOF ON NEW WOOD
DECK CONSTRUCTED ON
EXISTING DECK. SLOPE NEW
DECK 14" PER FOOT TO NEW
VALLEY
A2
A3
A3
A4
A2
A4
METAL CAP
FLASHING AT
MASONRY PARTY
WALL
SEE 3/A3 FOR
DETAIL
16 OZ MTL. STEPPED
CAP FLASHING.
ADJUST WIDTH TO
FOLLOW EXISTING
REGLET. FIELD VERIFY
EXACT LOCATION.
EXISTING MASONRY
CHIMNEY
REGLET DETAIL
NOT TO SCALE
A4
EXISTING BRICK MASONRY
WALL
EXISTING REGLET
RAKE OUT AND CLEAN
REGLET. CAP FLASHING SET
IN REGLET WITH LEAD
WEDGES AND FILLED WITH
BACKER ROD AND SEALANT.
HEM BOTTOM EDGE
OF CAP FLASHING
ROSIN PAPER
ROOF DECK
SHED ROOF DRIP EDGE
NOT TO SCALE
A4
ROOF DECK
SLIP SHEET AND
SELF ADHERING
WATERPROOFING
" HEM W/ SEAM
SEALANT
CONTINUOUS
CLEAT. LAP
AND SOLDER
ADJACENT
LENGTHS
SNAP
ROOFING
OVER
CONTINUOUS
CLEAT
PITCH
P
IT
C H
P
IT
C H
P
IT
C H
SIM.A4
SEAM SEALANT AT
ALL JOINTS BETWEEN
PANELS
DATE:
SUB SHEET NO. DRAWING NO.
PKG.
NO.
SHEET
OF
TITLE OF SHEET
WLB/PFS
WC
9/25/10 Rev. 12/10/20
A5
408 LOCUST STREET
ROOFING DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
173925
SERVICE WING
COUNTER FLASHING DETAIL
SCALE: 3"=1'-0"
A5
EXISTING ROOF
DECK
SELF ADHERING
WATERPROOFING
SLIP SHEET
SHEET METAL
ROOF
2" CONTINUOUS
CLEAT SOLDERED
2" METAL CLIP AT
1'-0" O.C.
METAL COUNTER
FLASHING
3/4" EXT. GRADE
PLYWOOD
SELF ADHERING
WATERPROOFING
SLIP SHEET
METAL COUNTER
FLASHING
EXT. WOOD DECK
SELF ADHERING
WATERPROOFING
SLIP SHEET
STANDING SEAM
METAL ROOF
DORMER SILL FLASHING
SCALE: 3"=1'-0"
A5
EXISTING ROOF DECK
SELF ADHERING WATERPROOFING
SLIP SHEET
STANDING SEAM METAL ROOF
2" CONTINUOUS METAL CLIP
METAL SILL FLASHING
WOOD DORMER SILL, SHAPE
MAY VARY FROM THAT SHOWN.
DORMER CHEEK
FLASHING DETAIL
SCALE: 3"=1'-0"
A5
METAL ROOF
TURN UP METAL ROOF AS
FLASHING
2" METAL CLIP AT 1'-0" O.C.
HOLD SIDING UP 1"
FROM METAL ROOF
SLIP SHEET
SELF ADHERING WATERPROOFING
WOOD SIDING. PRIME NEW
SIDING ALL SIDES INCLUDING
END CUTS. RUN PARALLEL TO
ROOF SLOPE