This document outlines requirements for a federal contract to supply and deliver one precast concrete utility building to the Mojave National Preserve in California. The utility building must measure 10.5 feet by 12 feet and include a single entrance door and vent. It must be delivered to Valley View Ranch within 60 days of award. The concrete must meet minimum strength requirements and the building must be placed at the delivery location using a crane according to the manufacturer's instructions. Relevant documentation including specifications, floor plans, manuals, and warranty information must be provided at delivery.

The related federal contract opportunity is solicitation number 140P8123Q0080 to supply the precast concrete building to the Mojave National Preserve, issued by the National Park Service Pacific West Region of the Department of the Interior.

View the file

Other files

File Type Posted
Sol_140P8123Q0080_Amd_0001.pdf PDF
B09_Questions_and_answers_0001.pdf PDF
Sol_140P8123Q0080.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Mojave National Preserve

San Bernardino County, California

SUPPLY & Deliver Concrete Utility Building to Valley View Ranch

NATIONAL PARK SERVICE

Mojave National Preserve

MOJA – DELIVER CONCRETE UTILITY BUILDING

SUPPLIES PURCHASE REQUEST: DELIVER CONCRETE UTILITY BUILDING

1. BACKGROUND

The Mojave National Preserve is located between Los Angeles and Las Vegas, south of the Interstate 15 freeway and about 65 east of Barstow CA. This contract is for the procurement of one 10’-6” x 12’ precast concrete utility building with vent and single entrance door delivered to Valley View Ranch within the Preserve. The building will be used to store batteries for the solar power system at the Ranch. NPS will prepare the delivery site based on the vendors specifications in preparation of the delivery. Contractor will provide delivery of structure and crane to place the utility building in prepared location and with help of NPS to assure structure is placed properly to manufactures recommendation.

2. PRODUCT REQUIREMENTS

Under this contract one concrete utility building shall be provided by contractor/vendor meeting or exceeding the salient characteristics of the CXT 10.5’ X 12’ Schweitzer Building:

1. Office dimensions: 10.5’ X 12’

2. Building layout: One large space, one door for access, and one vent.

3. Finished interior with painted floor, walls, doors, and ceiling.

4. Finished exterior with painted gable roof, stucco textured, painted exterior walls, and door

5. Company must be Precast/Prestressed Concrete Institute Certified

6. Panel Thickness: Floor 5”, Walls 4”, and Roof 4 ½”

7. Roof shall be gabled style with cedar shingle looking texture

8. Materials concrete shall meet F’ci of 2500 PSI and F’C of 5000 PSI strength

9. Deliver concrete utility building to location specified below.

10. Use crane or equipment to place concrete building on prepared location with final placement of building meeting the manufactures installation instructions.

3. DELIVERY LOCATION:

Valley View Ranch, Nipton, CA 92364 Approximately 5 Miles South of I15 on Cima Road GPS Coordinates: 35.318650, -115.584803

See Delivery Location maps on next page.

MOJA – DELIVER CONCRETE UTILITY BUILDING

4. PERIOD OF PERFORMANCE:

All tasks and deliverables for this contract must be completed within 60 of days after award.

Days listed herein refer to calendar days.

5. TASKS:

Contractor / Vendor shall deliver, unload, and place one concrete utility building meeting the specifications outlined in this document at the delivery location specified.

6. DELIVERABLES:

• Provide specification cut sheets / floor plan for proposed concrete utility building.

• Provide all accessories, manuals, and warranty information with utility building at time of delivery.