8628199-REVA (VLF_LOOP ANTENNA ASSEMBLY OUTLINE AND INSTALLATION).pdf

PDF 46 KB Posted

Attached to
Very Low Frequency (VLF) Cross Loop Antennas Federal contract opportunity
Solicitation number
N66604-21-R-0270
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to Very Low Frequency (VLF) Cross Loop Antennas, newest first.
File Type Posted
8628196-REVA (QA TEST PROCEDURES FOR VLF_LF LOOP ANTENNA ASSEMBLY).pdf PDF
N6660421R0270.pdf PDF
8628190-REV- (ANTENNA ELEMENT ASSEMBLY).pdf PDF
8628191-REV- (INSERT LIFTING).pdf PDF
8628194-REV- (FERRITE BAR).PDF PDF
8628189-REV- (BLOCK SUPPORT).pdf PDF
N6660421R0270 Exh. A CDRLs.pdf PDF
N6660421R0270 Att. 1 GFP.pdf PDF
8628188-REV- (VLF_LF LOOP ANTENNA ASSEMBLY).pdf PDF
8628192-REV- (ANTENNA FRAME ASSEMBLY).PDF PDF
8628195-REV- (PLUG LIFTING INSERT).PDF PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

33.00

4.00 2.08

16.5

LEFT VIEW

3.030

16.5

BOTTOM VIEW

ITEM 7 OF 53711-8628188

HIDDEN FOR CLARITY

CONNECTOR, BULKHEAD

RECEPTACLE, 6 PIN,

GLASS REINFORCED

EPOXY

REVISION HISTORY

REV SHEET DESCRIPTION BY DATE APPROVED

A REVISED PER NOR-8628199-REV- RDSI 2020-04-29 C. SHAW

TABULATION OF DATA

WEIGHT 145 20 LBS

CRATED WEIGHT 332 20 LBS

OVERALL CRATED DIMENSIONS 39.25 X 39.25 X 8.25

CUBICAL CONTENT 16.6 CU FT

OPERATING MEDIUM -

OPERATING PRESSURE -

AMBIENT OPERATING TEMPERATURE -

RELATIVE HUMIDITY -

HULLNO.

215-897-8735

REFERENCES

TITLE

SUPERSEDING OR MODIFICATION

IDENT

INFORMATION:

PHONE:

CODE:

REVWT GRP

SCALE: N/A

D

SIZE

53711

CAGE CODE

SHEET 1 OF 1

8628199

NAVSEA DRAWING NO.

DEPARTMENT OF THE NAVY

NAVAL SEA SYSTEMS COMMAND

WASHINGTON NAVY YARD, DC 20376-0001

DIMENSIONAL TOLERANCES AND SURFACE FINISHES - UNLESS OTHERWISE SPECIFIED

.1

± TOL

.005

.02

DECIMALS ( )

WHOLE NUMBERS ARE ± 0.1 TOLERANCE

.XX

.X

.XXX

PLACES

1/326" TO 24"

>OR= TO 24" 1/16

DIMENSION

FRACTIONS ( )

< 6" 1/64

± TOL

5" TO 8"

DIMENSION

2" TO 5"

>OR= TO 15"

12" TO 15"

8" TO 12"

.126>OR= TO 24"

ALL PLASTICS

MACHINED

MOLDED

CONDITION ± TOL

.035

.010

WELDMENTS

DIMENSION

< 24"

± TOL

.062

+3/32 -1/16

+1/8 -3/32

+3/16 -1/8

+1/4 -1/4

+1/4 -3/16

TOLERANCE

+1/16 -1/16

CASTINGS

< 2"

WEIGHT CONTROL DATA

F=FWD A=AFT P=PORT S=STBD 0=CENTERLINE

I=INSTALL R=REMOVE XI=LOAD ITEM INSTALLED XR=LOAD ITEM REMOVED

USE SEPARATE LINES FOR EACH WT GRP, S/A, REV, WT INSTL, OR WT RMV

VERTICAL LEVERS IN FEET TO THE NEAREST HUNDREDTH OF A FOOT

LONGITUDINAL AND TRANSVERSE LEVERS IN FEET TO THE NEAREST TENTH OF A FOOT

WT

GRPREV NUMBER

SHIPALT LCG

REF

I, R

NOT APPLICABLE

XR

XI

WT

(LBS)

VCG

REF BL

F

A

OR

TCG

REF CL

P VAL

BY

S

SHIP APPLICABILITY

SHIP/CLASS REV

PREPARED BY

REVIEWED BY

LEAD ENGINEER

LOGISTICS

SUBSAFE PGRM DIR.

ACCEPTED FOR NAVSEA

2020-01-14

DATE

DATE

DATE

DATE

DATE

APPLICATION

NEXT ASSY USED ON

MATERIAL:

OR RECONSTRUCTION OF DOCUMENT.

DESTRUCTION NOTICE

DISTRIBUTION STATEMENT D:

DISTRIBUTION AUTHORIZED TO THE DEPARTMENT OF DEFENSE AND U.S.

SHALL BE REFERRED TO THE UNDERSEA INTEGRATION PROGRAM OFFICE

DESTROY BY ANY METHOD THAT WILL PREVENT DISCLOSURE OF CONTENTS

(PMW 770) OF THE PROGRAM EXECUTIVE OFFICER, COMMAND, CONTROL,

DoD CONTRACTORS ONLY; (CRITICAL TECHNOLOGY OR ADMINISTRATIVE/

DISSEMINATE IN ACCORDANCE WITH PROVISIONS OF DoD DIRECTIVE 5230.25.

(TITLE 50, U.S.C., APP. 2401 ET SEQ.), AS AMENDED. VIOLATIONS OF

SEC 2751, ET SEQ.) OR THE EXPORT ADMINISTRATIVE ACT OF 1979

WARNING: THIS DOCUMENT CONTAINS TECHNICAL DATA WHOSE EXPORT

THESE EXPORT LAWS ARE SUBJECT TO SEVERE CRIMINAL PENALTIES.

COMMUNICATIONS, COMPUTERS AND INTELLIGENCE; 4301 PACIFIC HIGHWAY,

SAN DIEGO, CA 92110-3127.

OPERATIONAL USE) (7/18/2019). OTHER U.S. REQUESTS

IS RESTRICTED BY THE ARMS EXPORT CONTROL ACT (TITLE 22, U.S.C.,

B B

A

7 5 4 2 1

A

C

D

8 7 5 4

C

D

2 1

( )MACHINED SURFACE FINISHES = 125MUIN (AA). BREAK ALL SHARP EDGES .01 TO .02.

ALL ANGLES ± 0 DEGREES 30 MINUTES. MATERIAL SPECIFICATIONS TOLERANCES APPLY TO

STOCK SIZES. THREAD DIMENSIONS AND DESIGNATIONS TO BE IN ACCORDANCE WITH NATIONAL

BUREAU OF STANDARDS HANDBOOK H-28. UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS

ARE IN INCHES AND FEATURES ARE SYMMETRICAL ABOUT CENTERLINE. AMERICAN SOCIETY OF

MECHANICAL ENGINEERS ASME Y14.5 AND ASME Y14.100 ARE INVOKED WHERE APPLICABLE.

NAVAL SURFACE WARFARE CENTER

PHILADELPHIA DIVISION

PHILADELPHIA, PA 19112-1403

CAGE CODE 25685

M. GUTIERREZ

F. ZANNINI

L. FOSTER

C. SMITH

D. PORTOFEE

2019-12-11

2019-12-19

2019-12-11

2019-12-19

VLF/LF LOOP

ANTENNA ASSEMBLY

NOTES:

DENOTES CENTER OF GRAVITY.1.

ANTENNA ASSEMBLY SHIPPED WITH PROTECTIVE CAP, ITEM 7, 2.

ON BULKHEAD CONNECTOR, ITEM 8; SPECIFIED ITEMS CAN

BE FOUND ON DRAWING 53711-441-8628188.

MANUAL LIFTING OF THE ANTENNA IS PROHIBITED. THE 3.

ANTENNA SHALL BE LIFTED USING FOUR 1/2-13 EYE BOLTS

THREADED INTO THE FOUR ANTENNA LIFT POINTS USING AN

EQUAL-LENGTH, SINGLE-APEX, FOUR-LEGGED SLING. THE

MINIMUM SLING LEG LENGTH SHALL BE 36 INCHES. IN THE

EVENT OF A CONFLICT BETWEEN LOCAL RIGGING REGULATIONS

AND THESE INSTRUCTIONS, THE LOCAL RIGGING REGULATIONS

SHALL TAKE PRECEDENCE.

AD. GLINKA

UNCLASSIFIED//FOR OFFICIAL USE ONLY

UNCLASSIFIED//FOR OFFICIAL USE ONLY

2020-01-14

2020-01-14

OUTLINE AND INSTALLATION

Sheet1
Drawing View1
Drawing View5

File details come from the government source that posted it. Updated .