80DOT-S3642 - Triple Barrel 90 in End Section Drawing with Pipe Stub_Lawrence.pdf

PDF 761 KB Posted

Attached to
Culvert Pipe
Solicitation number
80DOT-S3642
Issued by
Churchill County, Nevada

About this file

This is a technical specification and drawing document from the Nevada Department of Transportation for a culvert repair and retrofit project located at SR439 and Innovation Way. The project requires the fabrication and delivery of three (3) custom 90-inch triple barrel metal end sections designed to specifications detailed in the engineering drawings. These end sections will be installed onto nine (9) existing 90-inch, 14-gauge corrugated metal pipe (CMP) culverts currently spaced at approximately 11 feet 6 inches on center with an outside-to-outside dimension of 48 inches. The vendor is responsible for all shop welded connections prior to delivery, while field connections (butt welds and strapping) will be performed by the Department. The three end sections consist of three different segments (Segment 1, Segment 2, and Segment 3) positioned as left, center, and right sections respectively, each with specific edge preparations and trimming requirements to maintain the required 48-inch spacing and facilitate field connections.

The specification drawings dated January 15, 2016, provide detailed dimensional requirements for each segment, including edge cutting, rolling, bending, and stiffening instructions to ensure proper fit and connection capability. Segment 1 (left side) requires a 44.5-inch edge dimension, Segment 2 (center) requires 41.5-inch edge dimensions on both sides, and Segment 3 (right side) requires a 44.5-inch left edge dimension. Each segment includes 24-inch connection zones with a minimum 4-inch overlap requirement for field welding or strapping. The document does not contain information regarding pricing, bidding deadlines, contract award dates, or funding sources.

View the file

Other files

File Type Posted
Terms-and-conditions-for-goods (1).pdf PDF
Quote Instructions (2).pdf PDF
Quote Instructions.pdf PDF
Quote Instructions (1).pdf PDF
NDEQ026399 - Photo.jpeg JPEG file
Certification-regarding-lobbying~4.pdf PDF
Terms-and-conditions-for-goods~2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEVADA DEPARTMENT OF TRANSPORTATION

SR439 at Innovation Culvert Repair and Retrofit with Three (3) Custom 90" Triple Barrel Metal End Sections

90" Triple End Section Special Detail Segment 2 of 3 01/15/2016

Date: 01/15/26 AJL in?

Front View Detail:

As assembled - three (3) 90" Triple Barrel Metal End Sections

Project Description: Fabricate and deliver three (3) Custom 90" Triple Barrel Metal End Sections to the dimensions and details shown. Shop welded connections shown to be performed by vendor and prior to delivery. Field connection locations should be prepared as shown or alternates approved by the Department. Field connections will be performed by the Department.

The Metal end sections will be installed in the field onto nine (9) 90" 14 guage CMP culvert pipes located at SR439 and Innovation way. The pipes are currently installed at roughly 11' 6" O.C. with an outside to outside dimension of approximately 48" O.C as shown. Segment connections as shown will be by field welding or strapping and will be performed by the Department. To maintain 48" outside to outside pipe spacing, each end section segment will be different as shown.

FRONT VIEW AS ASSEMBLED

Field Connection Field Connection

90" 90" 90" 4' 0" 4' 0" 90" 90" 90" 4' 0" 4' 0" 90" 90" 90" 4' 0" 4' 0" 4' 0" 4' 0"

Field Butt Weld Field Butt Weld

Segment 1 Segment 2 Segment 3

OVERALL END SECTION WIDTH

9 Barrel End Section

TOP VIEW AS ASSEMBLED

NEVADA DEPARTMENT OF TRANSPORTATION

SR439 at Innovation Culvert Repair and Retrofit with Three (3) Custom 90" Triple Barrel Metal End Sections

90" Triple End Section Special Detail Segment 2 of 3 01/15/2016

Date: 01/15/26 AJL in?

Top View Detail:

As assembled - three (3) 90" Triple Barrel Metal End Sections

Field Connection Field Connection

NEVADA DEPARTMENT OF TRANSPORTATION

SR439 at Innovation Culvert Repair and Retrofit with Three (3) Custom 90" Triple Barrel Metal End Sections

90" Triple End Section Special Detail Segment 1 of 3 01/15/2016

Date: 01/15/26 AJL

444 " +/- (right edge cut or rolled)

Segment #1 (Facing Downstream Left Side) (Right side trim to maintain 48" spacing)

Cut,roll, bend, or stiffen edge to maintain shape and accept field welding or strapping to connect adjacent segments. See example field connections performed by others

Cut,roll, bend, or stiffen edge to maintain shape and accept field welding or strapping to connect adjacent segments.

Example Connection(s) 444 " +/- (right edge cut or rolled)

24"

24"

Segment 1

Segment 2

Strap

Segment 1

Segment 2

Segment 1 Segment 2

4" m in?

4 " m in?

m in

SEGMENT

Cut,roll, bend, or stiffen edge to maintain shape and accept welding or strapping to connect adjacent segments. See example field connections to be performed by others.

Segment #2 (Facing Downstream Center Section) (Left and Right side trim to maintain 48" spacing)

Cut,roll, bend, or stiffen edge to maintain shape and accept welding or strapping to connect adjacent segments. See example field connections to be performed by others

Cut,roll, bend, or stiffen edge to maintain shape and accept welding or strapping to connect adjacent segments. See example field connections performed by others

414 " +/- (right/left edge cut or rolled)

414 " +/- (right/left edge cut or rolled)

24"24"

24" 24"

NEVADA DEPARTMENT OF TRANSPORTATION

SR439 at Innovation Culvert Repair and Retrofit with Three (3) Custom 90" Triple Barrel Metal End Sections

90" Triple End Section Special Detail Segment 2 of 3 01/15/2016

Date: 01/15/26 AJL

Segment 1

Segment 2 Example Connection(s)

Strap

Segment 1

Segment 2

Segment 1 Segment 2

4" m in?

4 " m in?

m in

Cut,roll, bend, or stiffen edge to maintain shape and accept field welding or strapping to connect adjacent segments. See example field connections performed by others.

Cut,roll, bend, or stiffen edge to maintain shape and accept welding or strapping to connect adjacent segments. See example field connections to be performed by others.

Segment #3 (Facing Downstream Right Section) (Left side trim to maintain 48" spacing)

Example Connection(s)

Cut,roll, bend, or stiffen edge to maintain shape and accept welding or strapping to connect adjacent segments. See example field connections to be performed by others

444 " +/- (left edge cut or rolled)

444 " +/- (left edge cut or rolled)

24"

24"

NEVADA DEPARTMENT OF TRANSPORTATION

SR439 at Innovation Culvert Repair and Retrofit with Three (3) Custom 90" Triple Barrel Metal End Sections

90" Triple End Section Special Detail Segment 3 of 3 01/15/2016

Date: 01/15/26 AJL

Segment 2

Segment 3

Strap

Segment 2

Segment 3

Segment 2 Segment 3

4" m in?

4 " m in?

m in

File details come from the government source that posted it. Updated .