About this file
This is a product specification document for ZYME-OUT, a degassing agent and odor eliminator manufactured by United Laboratories, Inc., related to a drain cleaning services contract opportunity issued by the City of Detroit Office of Contracting and Procurement (OCP) on behalf of the Construction and Demolition Department. The City of Detroit seeks qualified respondents to provide drain cleaning services at municipal facilities over a three-year contract period. ZYME-OUT is specifically designed to mask and eliminate hydrogen sulfide odors within fifteen minutes and is suitable for application in wastewater treatment plants, pulp and paper mills, and similar industrial environments. The product disperses completely in water without residue, provides flocculent properties to catalyze waste breakdown, and helps control grease buildup.
ZYME-OUT is an Earth Smart Certified formulation containing no hazardous components, volatile organic compounds (VOCs), or restricted ingredients, with a rating of zero across all Hazardous Materials Identification System (HMIS) categories. The product is non-toxic according to EPA, OSHA, NIOSH, and WHMIS standards, non-flammable, maintains a near-neutral pH, and requires no special material safety handling or closed space precautions. Application methods include in-line injection at a ratio of one part product per 5,000 to 10,000 parts raw influent, misting with spray heads at dilutions of 75 to 210 parts water, fogging applications using a 100:1 solution with specialized equipment, and sludge odor control on belt presses and land applications at varying dilution rates determined through bench testing. The product is manufactured in the United States by United Laboratories, Inc., located in St. Charles, Illinois, with 24-hour access to safety data sheets available through the company website.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
United 894 Mask, Break and Eliminate Hydrogen Sulfide odors within Fifteen Minutes with ZYME-OUT.
• Disperses completely in water with no residue or precipitate from product.
| • | Provides flocculent properties. |
| • | Catalyzes the breakdown of wastes and helps control |
grease build-up.
• Ideal for use in wastewater treatment plants, as well as in pulp and paper mills in their lagoons and drying beds.
• Fresh, mild vanilla scent masks odors to immediately control problem.
Earth Smart® Certified Formulation
• No hazardous components, no VOCs, ranked zero in all HMIS categories.
• Non-toxic according to EPA, OSHA, NIOSH and
WHMIS standards.
| • | No restricted ingredients. |
| • | Non-flammable. Will not burn. |
| • | Near neutral pH. |
| • | No material safety handling or closed space problems. |
For application on the wastewater process side, please contact United Laboratories’ Technical Support Team for assistance.
DIRECTIONS:
Dilution rates will vary based upon the level and type of odor being controlled, the application method and the area to be treated.
For In-Line Injection: Use one part ZYME-OUT per 5,000-10,000 parts of raw influent. To determine exact dilution rates, conduct a bench test.
For Misting with Spray Heads or Spray Bars:
Dilute 75 to 210 parts of water in the dilution tank and spray continuously or activate by timer as needed. Use a fine mist to improve coverage.
For Fogging Applications: Mix a 100:1 solution in an empty drum and attach an A187 Pow-R-Jet Plus Drum Mount Fogger. An A185 Timer will control the activation of the fogger. Always allow a 15-minute cool-down period per hour with the Pow-R-Jet Plus Drum Mount Fogger.
DIRECTIONS: (continued) For Sludge Odor Control on Belt Presses: Use one part ZYME-OUT per 10,000 parts of 3% sludge. Less polymer may be needed.
For Sludge Odor Control on Land: Use one to five parts ZYME-OUT in the terragitator per 10,000 parts of liquid sludge to be spread. To determine exact dilution rates, conduct a bench test.
FIRST AID MEASURES:
IF IN EYES: Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Call a physician.
IF ON SKIN: Wash with soap and water. If skin irritation persists, call a physician.
IF INHALED: Remove to fresh air. Get medical attention if discomfort persists.
IF SWALLOWED: Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person. Call a physician or poison control center immediately.
An SDS for this product is available through United’s website, www.unitedlabsinc.com, providing 24 hour access. Please read the SDS carefully and follow all directions when using or handling this product. Never reuse empty containers. Incompatible materials may adversely react.
HMIS® III CODE:
0=MINIMAL 1=SLIGHT
2=MODERATE
3=SERIOUS 4=SEVERE
PERSONAL
PROTECTION INDEX:
Gloves and Goggles
HEALTH 0
FLAMMABILITY 0
PHYSICAL HAZARD 0
PERSONAL PROTECTION B
Manufactured and Printed in U.S.A. 517
ZYME-OUT
Degassing Agent and
Odor Eliminator
PATENTED
KEEP OUT OF REACH OF CHILDREN.
See other cautions on back/side panel.
PRECAUCION AL USARIO:
Si usted no puede leer Ingles, pregunte a alguien que le traduzca esta etiqueta para usted antes de uso.
Manufactured and Sold Exclusively By:
UNITED LABORATORIES, INC.
320 37th Avenue • St. Charles, IL 60174 1-800-323-2594 • www.unitedlabsinc.com
File details come from the government source that posted it. Updated .