DIKE PROFILES.2.pdf

PDF 168 KB Posted

Attached to
CA FLAP ED CR 147(2) Ice House Road
Solicitation number
6982AF22B000032
Issued by

About this file

This document contains engineering plans for dike profiles and details for a highway project in California. The plans specify five different dike types ranging from 0.0066 to 0.0293 cubic yards per linear foot, include construction details for cut slopes, backfill, and positioning relative to guardrails. Notes provide guidance on using particular dike types based on slope conditions and pavement types. The related federal contract opportunity is a solicitation from the Federal Highway Administration and Department of Transportation for the CA FLAP ED CR 147(2) Ice House Road project.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Var 4:1

ES ES

Var

ES

Var Var

R=1"

R=1" R=1"

R=1"

3"

2"

Var

2" 2"

ES

5%

5%

ES

FL

FL

FLFL FL

ES

3"

ES

TYPE A

ES

TYPE C TYPE D TYPE E TYPE F

See Note 5

CASE C-1 CASE C-2

Cut Slope Cut Slope

CASE R

See Note 2

DIKES

TYPE D AND E BACKFILL DETAILS

CASE F

3’-0"

5"

6"

4"

3’-0"

1’-8"

6"

2’-2"

1’-0"

1’-4"

4"

4"

4:1

SEE NOTE 1

LEVEL LINE

SEE NOTE 1

LEVEL LINE

SEE NOTE 1

LEVEL LINE

SEE NOTE 1

Var CUT SLOPE

SEE NOTE 1

SEE NOTE 4

LEVEL LINE

LEVEL LINE

SEE NOTE 4

SLOPE T

O DRAIN

NO SCALE

NOTES:

STATE OF CALIFORNIA

DEPARTMENT OF TRANSPORTATION

HOT MIX ASPHALT DIKES

COUNTY ROUTE

POST MILES

TOTAL PROJECT

SHEET TOTAL

SHEETS

PLANS APPROVAL DATE

No.

Exp.

R E

G I

S T

E R

E

D

P

ROFESSIONA

L

E

N G I

N E

E R

S

T A

TE OF CALIF

ORN

IA

REGISTERED CIVIL ENGINEER

Michael Janzen

44788

CIVIL

Dist No.

THE STATE OF CALIFORNIA OR ITS OFFICERS

OR AGENTS SHALL NOT BE RESPONSIBLE FOR

COPIES OF THIS PLAN SHEET.

THE ACCURACY OR COMPLETENESS OF SCANNED

cross slope.

Quantities based on 5%

5.

4.

3.

2.

1.

4"

ES

LINE

LEVEL

:1

:1

5’-0" FOR TYPE D

3’-0" FOR TYPE E

F

E

D

C

A

TYPE

QUANTITIES

DIKE

0.0066

0.0130

0.0293

0.0038

0.0135

PER LINEAR FOOT

CUBIC YARDS

3-31-16

11-17-15

January 15, 2016

See Notes 3 and 5 for hinge point offsets with guardrail.

Standard Plan A77N4 for dike positioning details. See Standard Plan A77N3

Use Type A or F dike, where dike is required with guardrail installations. See

Fill and compact with excavated material to top of dike.

enough width to use Type D or Type E dike.

Type A dike only to be used where restrictive slope conditions do not provide provide enough width for Case F backfill.

Case R applies to retrofit only projects where restrictive conditions do not

OGFC under dike. See project plans for modified dike detail.

dike with no joint at the ES. For projects with OGFC shoulders, do not extend

For HMA shoulders only, extend top layer of HMA placed on the shoulder under

R

V I S

D

S T

A N

D A

D

P L

N

S

P

B

REVISED STANDARD PLAN RSP A87B

DATED OCTOBER 30, 2015 - PAGE 126 OF THE STANDARD PLANS BOOK DATED 2015.

RSP A87B DATED JANUARY 15, 2016 SUPERSEDES STANDARD PLAN A87B

TO ACCOMPANY PLANS DATED

All Rights Reserved c 2016 California Department of Transportation rspa87b