60691532_Patrick County Business Development Center_100_ Construction Drawing.pdf
PDF 23 MB Posted
- Attached to
- IFB #2025-81500-01
- Solicitation number
- 76177
- Issued by
- Page County, Virginia
About this file
This document is a set of construction drawings for the Patrick County Business Development Center project. The drawings were prepared by an architectural firm and include detailed specifications for the 100% construction design of the new facility. The project is being undertaken by Patrick County, located in Virginia. The drawings provide a comprehensive overview of the proposed building, including site plans, floor plans, elevations, sections, and various design details. No specific information is provided regarding the procurement process, response dates, or award timeline for this construction contract.
The drawings do not contain any details on pricing, set asides, incumbents, funding sources, or other contractual terms. This appears to be a design document rather than a procurement solicitation, so those elements are not included. The drawings focus solely on the technical specifications and design of the proposed Patrick County Business Development Center facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SITE
JEB STUART HW
Y
W O
O D
BR
O
TH
ER
S
DR
BU
SI
NE
SS
P
AR
K
RD
SL
US
HE
R
ST
Th is d ra w in g ha s be en p re pa re d fo r t he u se o f A E
C O
M ’s c lie nt . I t m ay n ot b e us ed
, m od ifi ed
, r ep ro du ce d or re lie d up on b y th ird p ar tie s, e xc ep t a s ag re ed b y
A E
C O
M o r a s re qu ire d by la w . A
E C
O M a cc ep ts n o re sp on si bi lit y, a nd d en ie s an y lia bi lit y w ha ts oe ve r, to a ny p ar ty th at u se s or re lie s on th is d ra w in g w ith ou t A
E C
O M
’s e xp re ss w rit te n co ns en t.
D o no t s ca le th is d oc um en t.
A ll m ea su re m en ts m us t b e ob ta in ed fr om th e st at ed d im en si on s.
www.aecom.com
1 2 3 4 5
D
C
B
A
6 7
E
F
PROJECT
CLIENT
CONSULTANT
REGISTRATION
PATRICK COUNTY
EDA
106 Rucker Street, Stuart, VA, 24171
10 South Jefferson Street, Suite 1600
540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
100% CONCEPT DESIGN
©2016 AECOM Corporation
11/01/2022
AECOM
PATRICK COUNTY
BUSINESS DEVELOPMENT
CENTER PROJECT
132/136 SLUSHER ST.
STUART, VA
100% CD SUBMITTAL SET01/17/2023 I
I
COVER SHEET
G-001
60691532
100% CONSTRUCTION DOCUMENT SUBMITTAL
LOCATION MAP
STUART, VIRGINIA
JANUARY 17, 2023
AECOM PROJECT NO. 60691532
N
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME
MECHANICAL
M-001 MECHANICAL LEGEND AND GENERAL NOTES
MH-101 LOWER LEVEL DUCTWORK PLAN
M-102 UPPER LEVEL HVAC PLAN
M-103 ROOF HVAC PLAN
MP-101 LOWER LEVEL PIPING PLAN
M-301 SECTIONS
M-501 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-701 MECHANICAL CONTROLS
M-702 MECHANICAL CONTROLS
M-703 MECHANICAL CONTROLS
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS AND LEGEND
E-002 ELECTRICAL SPECIFICATIONS
EL101A LOWER LEVEL LIGHTING PLAN - AREA A
EL101B LOWER LEVEL LIGHTING PLAN - AREA B
EL102A UPPER LEVEL LIGHTING PLAN - AREA A
EL102B UPPER LEVEL LIGHTING PLAN - AREA B
EP101A LOWER LEVEL POWER PLAN - AREA A
EP101B LOWER LEVEL POWER PLAN - AREA B
EP102A UPPER LEVEL POWER PLAN - AREA A
EP102B UPPER LEVEL POWER PLAN - AREA B
EP103 ROOF POWER PLAN - OVERALL
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-601 ELECTRICAL ONE-LINE DIAGRAM
E-701 ELECTRICAL PANEL SCHEDULES
E-702 ELECTRICAL PANEL SCHEDULES
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME
A411 LOWER LEVEL - INTERIOR ELEVATIONS
A412 UPPER LEVEL - INTERIOR ELEVATIONS
A511 SECTION DETAILS
A521 CEILING DETAILS
A551 STAIRCASE AND RAMP DETAILS
A552 STAIRCASE AND RAMPS - UPPER LEVEL
A553 EXTERIOR STAIRCASE
A601 PARTITION TYPES
A611 DOOR SCHEDULE & DETAILS
A615 DOOR DETAILS
A621 WINDOW DETAILS
A701 LOWER LEVEL - CASEWORK DETAILS
A702 UPPER LEVEL - CASEWORK DETAILS
A710 ARCHITECTURE SPECIFICATIONS
INTERIORS
IN101 INTERIOR FINISH PLAN - COMPOSITE
IN102 LOWER LEVEL - INTERIOR FINISH PLAN AREA A
IN103 LOWER LEVEL - INTERIOR FINISH PLAN AREA B
IN104 UPPER LEVEL - INTERIOR FINISH PLAN AREA A
IN105 UPPER LEVEL - INTERIOR FINISH PLAN AREA B
IN601 LOWER LEVEL INTERIOR FINISH LEGEND AND ROOM FINISH SCHEDULE
IN602 UPPER LEVEL INTERIOR FINISH LEGEND AND ROOM FINISH SCHEDULE
IF101 FURNITURE PLAN - COMPOSITE
IF102 LOWER LEVEL - FURNITURE PLAN AREA A
IF103 LOWER LEVEL - FURNITURE PLAN AREA B
IF104 UPPER LEVEL - FURNITURE PLAN AREA A
IF105 UPPER LEVEL - FURNITURE PLAN AREA B
IF601 LOWER LEVEL - FURNITURE SCHEDULE
IF602 UPPER LEVEL - FURNITURE SCHEDULE
IF603 UPPER LEVEL - FURNITURE SCHEDULE CONT.
FIRE PROTECTION
FA001 FIRE ALARM GENERAL NOTES AND LEGEND
FA101 FIRST FLOOR FIRE ALARM PLAN
FA102 SECOND FLOOR FIRE ALARM PLAN
FA501 FIRE ALARM DETAILS
FA701 FIRE ALARM SPECIFICATIONS
PLUMBING
P-001 LEGEND AND GENERAL NOTES
PU100 UNDERGROUND PLAN
PL101 LOWER LEVEL SUPPLY PLAN
PW101 LOWER LEVEL WASTE PLAN
P-102 UPPER LEVEL PLAN
P-501 DETAILS
P-601 SCHEDULES AND SPECIFICATIONS
P-901 SUPPLY RISER DIAGRAM
P-902 WASTE RISER DIAGRAM
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
G-002 ABBREVIATIONS
G-003 GENERAL SYMBOLOGY
GENERAL INFORMATION
GI001 LIFE SAFETY AND BUILDING CODE ANALYSIS
GI101 FIRST FLOOR LIFE SAFETY PLAN
GI102 SECOND FLOOR LIFE SAFETY PLAN
CIVIL
C-1 TITLE SHEET, EXISTING LAYOUT AND DETAILS
C-2 DEMOLITION PLAN AND DETAILS
C-3 LAYOUT PLAN AND DETAILS
C-4 GRADING AND EROSION AND SEDIMENT CONTROL PLAN AND DETAILS
C-5 GENERAL NOTES AND DETAILS
STRUCTURAL
S-001 GENERAL NOTES
S-101 FOUNDATION PLAN - COMPOSITE
S-101A FOUNDATION PLAN - AREA A
S-101B FOUNDATION PLAN - AREA B
S-102 SECOND FLOOR FRAMING PLAN - COMPOSITE
S-102A SECOND FLOOR FRAMING PLAN - AREA A
S-102B SECOND FLOOR FRAMING PLAN - AREA B
S-103 ROOF FRAMING PLAN - COMPOSITE
S-103A ROOF FRAMING PLAN - AREA A
S-103B ROOF FRAMING PLAN - AREA B
S-301 SECTIONS & DETAILS
S-302 SECTIONS & DETAILS
S-501 TYPICAL DETAILS
ARCHITECTURE
AD001 GENERAL DEMOLITION NOTES AND LEGEND
AD101 DEMOLITION FLOOR PLANS - COMPOSITE
AD101A LOWER LEVEL - DEMOLITION FLOOR PLAN AREA A
AD101B LOWER LEVEL - DEMOLITION FLOOR PLAN AREA B
AD102A UPPER LEVEL - DEMOLITION FLOOR PLAN AREA A
AD102B UPPER LEVEL - DEMOLITION FLOOR PLAN AREA B
AD152 UPPER LEVEL - DEMOLITION CEILING PLAN
A001 GENERAL NOTES AND LEGENDS
A101 LOWER LEVEL - NEW WORK FLOOR PLAN - COMPOSITE
A101A LOWER LEVEL - NEW WORK FLOOR PLAN AREA A
A101B LOWER LEVEL - NEW WORK FLOOR PLAN AREA B
A102 UPPER LEVEL - NEW WORK FLOOR PLAN - COMPOSITE
A102A UPPER LEVEL - NEW WORK FLOOR PLAN AREA A
A102B UPPER LEVEL - NEW WORK FLOOR PLAN AREA B
A103 ROOF PLAN
A151 LOWER LEVEL - CEILING PLAN COMPOSITE
A152 UPPER LEVEL - CEILING PLAN COMPOSITE
A201 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
A401 ENLARGED PARTIAL PLANS
INDEX OF DRAWINGS
I/R DATE DESCRIPTION
ABBREVIATIONS
YD YARD
YHYD YARD HYDRANT
ABBREVIATIONS
SSMR STANDING SEAM METAL ROOF
SST STAINLESS STEEL
ST STREET, STORY, STEAM, SEDIMENT TRAP, STONE
STA STATION
STD STANDARD
STER STERILIZER
STIF STIFFENER
STIR. STIRRUP
STL STEEL
STOR STORAGE
STP SHIELDED TWISTED PAIR
STR STRAIGHT, STARTER
STRL STRUCTURAL
STRUC STRUCTURE
SUBSTA SUSPENDED
SUP SUPPLY
SURF. SURFACE
SUSP SUSPENDED
SV SHEET VINYL, STEAM VENT
SVCE SERVICE
SW SHORT WAY, SWITCH, SIDEWALK
SWBD SWITCHBOARD
SWGR SWITCHGEAR
SYMM SYMMETRICAL
SYS SYSTEM
T TREAD, TOP, TANGENT, TELEPHONE, THICKNESS
T&B TOP AND BOTTOM
T&G TONGUE AND GROVE
T.O.W TOP OF WALL
TAF TOWEL APPLIED FINISH
TBB TELECOMMUNICATIONS BONDING BACKBONE
TBM TEMPORARY BENCH MARK
TC TIME CLOCK, TOP OF CURB
TD TRENCH DRAIN
TDC TURNED DOWN CURB
TEF TELECOMMUNICATIONS ENTRANCE FACILITY
TEL TELEPHONE
TEMP TEMPERATURE, TEMPERED, TEMPORARY
TER TERRAZZO
TERM. TERMINAL
TFE TETRAFLUOROETHYLENE
TG TOP GRILLE
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
THERM. THERMOMETER
THK THICK
THKNS THICKNESS
THR THRESHOLD
TKBD TACKBOARD
TLSD TOP LINEAR SLOT DIFFUSER
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TMV THERMAL MIXING VALVE
TO. TELECOMMUNICATIONS OUTLET
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOS TOP OF STEEL
TOT. TOTAL
TP TREE PROTECTION, TOILET PARTITION
TR TOP REGISTER, TOP OF RAIL, TELECOM ROOM
TRANSV TRANSVERSE
TRTD TREATED
TS TEMPERATURE STEEL, TIME SWITCH, TAMPER
SWITCH, TEMPORARY SWITCH, THICKENED SLUDGE,
TEMPORARY SEEDING, TRAVERSE STATION
TSD TEMPORARY SLOPE DRAIN
TSP TWISTED SHIELDED PAIR
TST TWISTED SHIELDED TRIPLE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TV TELEVISION, TELEVISION OUTLET
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TYP TYPICAL
U.S. URINAL SCREEN
UC UNDERCUT, UNDERCOUNTER
UF UNDERFLOOR
UFD UNDERFLOOR DUCT
UG UNDERGROUND
UH UNIT HEATER
UHF ULTRAHIGH FREQUENCY
UL UNDERWRITERS LABORATORY
ULT ULTIMATE
UNIF UNIFORM
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTABLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UTP UNSHIELDED TWISTED PAIR
V VOLTAGE, VOLT, VENT, VALVE
VA VOLT-AMPERE
VAC VACUUM VOLTS AC, MEDICAL VACUUM
VAR VOLT-AMPERE REACTIVE
VAV VARIABLE AIR VOLUME
VB VAPOR BARRIER
VC VERTICAL CURVE
VCP VITRIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VD VOLUME DAMPER
VDC VOLTS DC
VEL VELOCITY
VENT VENTILATE / VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VHF VERY HIGH FREQUENCY
VIB VIBRATION
VIF VERIFY IN FIELD
VIS VINYL STAIR TREADS AND RISERS
VLT VAULT
VM VOLTMETER
VOL VOLUME
VR VAPOR RETARDER
VS VERTICAL SLOT
VT VINYL TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST, WIDTH/WIDE
W/ WITH
W/O WITHOUT
WA WAINSCOT
WAGD WASTE ANESTHESIA DISPOSAL
WAS WASTE ACTIVATED SLUDGE
WB WET BULB, WIND BEAM
WC WATER CLOSET, WALL COVERING, WINDOW
COVERING
WD WOOD, WIDTH
WDO WINDOW
WFD WATER FLOW DETECTOR
WG WALL GUARD, WATER GAGE
WH WALL HYDRANT
WHA WATER HAMMER ARRESTER
WHS WELDED HEAD STUD
WI WROUGHT IRON
WL WIND LOAD, WATER LINE
WM WATER METER
WP WORKING POINT, WATERPROOF
WPF WATERPROOFING
WS WATER SURFACE, WATERSTOP
WST WASTE
WT WEIGHT, WINDOW TREATMENT
WTR WATER
WTS WELDED THREADED STUD
WV WATER VALVE, WOOD VENEER
WWR WELDED WIRE FABRIC (WELDED WIRE
REINFORCEMENT)
XARM CROSS ARM
XFMR TRANSFORMER
XFR TRANSFER
XMIT TRANSMITTER
XP EXPLOSION PROOF
ABBREVIATIONS
OZ OUNCE
P POLE, POWER, PUMP
P.F. POWER FACTOR
P.R.S PRESSURE REDUCING STATION
PA PIPE ANCHOR, PUBLIC ADDRESS
Pa PASCAL
PB PUSH BUTTON, PANEL BOARD, PULL BOX
PC POINT OF CURVE
PCC POINT OF COMPOUND CURVE, PRECAST CONCRETE,
PORTLAND CEMENT CONCRETE
PCP PRECAST CONCRETE PANEL
PCSP PRECAST CONCRETE SANDWICH PANEL
PD PRESSURE DROP
PDS PROTECTED DISTRIBUTION SYSTEM
PDU POWER DISTRIBUTION UNIT
PED PEDESTAL
PEJ PREMOLDED EXPANSION JOINT
PET PROTECTED ENTRANCE TERMINAL
PF POROUS FILL
PG PIPE GUIDE, PAGE, PRESSURE GAUGE
PH PHASE, PENTHOUSE
PHR PREHEAT RETURN
PHS PREHEAT SUPPLY
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLATF PLATFORM
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL
PNLBD PANELBOARD
PNT PAINT, PAINTED
POB POINT OF BEGINNING
POL POLISH, POINT ON LINE
PP POWER POLE
PPH POUNDS PER HOUR
PR PAIR
PRC POINT OF REVERSE CURVE
PREFIN PREFINISHED
PRESS. PRESSURE
PRI PRIMARY
PRL PARALLEL
PROP. PROPOSED
PROV PROVIDED
PRV PRESSURE REDUCING VALVE, POWER ROOF
VENTILATION
PS PRESSURE SWITCH, PERMANENT SEEDING, POINT
OF SWITCH
PSC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAGE
PT POINT OF TANGENT, POTENTIAL TRANSFORMER
PTN PARTITION, PORCELAIN TILE
PVC POINT OF VERTICAL CURVE, POLYVINYL CHLORIDE
PVI POINT OF VERTICAL INTERSECTION
PVMT PAVEMENT
PVR PAVER
PVT POINT OF VERTICAL TANGENT, PRIVATE
PWR POWER
TB PORCELAIN CERAMIC TILE BASE
QT QUARRY TILE
QTZ QUARTZ
R RADIUS, RIGHT, RISER
R/W RIGHT OF WAY
RA RETURN AIR
RAD RADIUS
RAF RAISED ACCESS FLOORING
RAS RESILIENT BASE / RUBBER BASE, RETURN
ACTIVATED SLUDGE
RB RUBBER BASE
RBR RUBBER
RCP REINFORCED CONCRETE PIPE
RCPT RECEPTACLE
RCRC RESINOUS CHEMICAL, RESISTANT COATING
RCRTC RESINOUS CHEMICAL RESISTANT TRAFFIC COATING
RCVG RECEIVING
RCVR RECEIVER
RD ROOF DRAIN, ROAD
RDCR REDUCER
REC RECESS
RECIR RECIRCULATING
RECT RECTANGLE, RECTANGULAR
RED. REDUCING
REF REFERENCE
REFL REFLECTED
REFR REFRIGERATOR
REINF REINFORCE, REINFORCEMENT, REINFORCED
REM REMAINDER
REQD REQUIRED
RESIL RESILIENT
REV REVISION
RF ROOF, RADIO FREQUENCY, RESILIENT FLOOR
RFG ROOFING
RFH ROOF HATCH
RFI RADIO FREQUENCY INTERFERENCE
RL ROOF LEADER, REFRIGERANT LIQUID
RM ROOM
RND ROUND
RO ROUGH OPENING
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
RPM REVOLUTION PER MINUTE
RR RIPRAP, RAILROAD
RS ROLLER SHADE
RTE ROUTE
S SOUTH, SANITARY, SEWER, SPEAKER, SWITCH,
SUPPLY
S/N SOLID NEUTRAL
SA SUPPLY AIR
SAN SANITARY
SCFM STANDARD CUBIC FEET PER MINUTE
SCHED SCHEDULE
SCONC SEALED CONC
SD STORM DRAIN, SMOKE DETECTOR
SDF STATIC DISSIPATIVE FLOORING
SDMH STORM DRAIN MANHOLE
SDT STATIC DISSIPATIVE TILE
SEC SECONDARY
SECT SECTION
SF SILT FENCE, SQUARE FEET
SFM SEWER FORCE MAIN
SFP SPRAYED FIRE PROTECTION
SH SHEET
SHV SHELVING
SIM SIMILAR
SK SKETCH
SLP SLOPE
SMH SEWER MANHOLE
SMR SURFACE METAL RACEWAY
SNT SEALANT
SOG SLAB ON GRADE
SP SPACE, SPACES, STATIC PRESSURE, SERVICE
PROVIDER
SPD STATIC PRESSURE DROP, SURGE PROTECTION
DEVICE
SPEC SPECIFICATIONS
SPKR SPEAKER
SPMR SINGLE-PLY MEMBRANE ROOF
SPR SPRINKLER
SPRT SUPPORT
SPS STATIC PRESSURE SENSOR
SQ SQUARE
SRV SURGE RELIEF VALVE
SS SANITARY SEWER, SOLID SURFACE, SAFETY SWITCH
SSD SUBSURFACE DRAIN, SECONDARY STORM DRAIN
SSK SOIL STACK
ABBREVIATIONS
kHZ KILOHERTZ km KILOMETER kN KILONEWTON
KO KNOCKOUT
kPa KILOPASCAL
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
kV KILOVOLT kVA KILOVOLT-AMPERE kVAR KILOVOLT-AMPERE REACTIVE kW KILOWATT kWH KILOWATT HOUR
L LEFT, LENGTH OF CURVE, LONG
L-G LINE TO GROUND
L-L LINE TO LINE
L-N LINE TO NEUTRAL
L.W.T LEAVING WATER TEMPERATURE
LA LIGHTENING ARRESTER
LAB LABORATORY
LAM LAMINATE
LAN LOCAL AREA NETWORK
LAT LATITUDE, LATERAL
LAV LAVATORY
LB POUND
LCG LACING
LCP LIGHTING CONTROL PANEL
LDG LOADING
LED LIGHT EMITTING DIODE
LF LINEAR FOOT, LINEAR FEET
LFMC LIQUID LIGHT FLEXIBLE METAL CONDUIT
LG LENGTH, LONG
LI LONG TIME INSTANTANEOUS
LIQ LIQUID
LKR LOCKER
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCATE
LONG. LONGITUDINAL
LP LIQUEFIED PROPANE
LPS LOW PRESSURE SODIUM, LIGHTING PROTECTION
SYSTEM
LPT LOW POINT
LR LONG RADIUS, LINEAR REGISTER
LS LUMP SUM, LIMIT SWITCH, LONG TIME SHORT TIME
LSG LONG TIME SHORT TIME GROUND FAULT
LSI LONG TIME SHORT TIME INSTANTANEOUS
LSIG LONG TIME SHORT TIME INSTANTANEOUS GROUND
FAULT
LT LIGHT
LTG LIGHTING
LV LOW VOLUME
LVR LOUVER
LVT LUXURY VINYL TILE
LW LONG WAY, LIMIT OF WORK
LWC LIGHTWEIGHT CONCRETE
LWL LOW-WATER LINE
lx LUX
M MICROPHONE, MANUAL
m METER
M/G MOTOR GENERATOR
MACH MACHINE
MAG MAGNETIC
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION
MAX MAXIMUM
MBH 1000 BTU PER HOUR
MBR MEMBER
MC MAIN CROSS CONNECT
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MCCB MOTOR CASE CIRCUIT BREAKER
MCOV MAXIMUM CONTINUOUS OPERATING VOLTAGE
MCP MOTOR CIRCUIT PROTECTOR
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MEMB MEMBRANE
MER MAIN EQUIPMENT ROOM
MET. METAL
MFR MANUFACTURER
MGD MILLION GALLONS PER DAY
MH MANHOLE, MOUNTING HEIGHT, METAL HALIDE
MHz MEGAHERTZ
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
MK MARK
MKBD MARKER BOARD
MLO MAIN LUGS ONLY
mm MILLIMETERS
MO MASONRY OPENING
MON MONUMENT
MOV METAL OXIDE VARISTOR
MP MEDIUM PRESSURE
MPa MEGAPASCAL
MPH MILES PER HOUR
MR MOP RECEPTOR, MOISTURE RESISTANT
MSL MEAN SEA LEVEL
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTR MOTOR
MTZ MOTORIZED
MU MULCHING
MUL MULLION
MUTCO MANUAL OF UNIFORM TRAFFIC CONTROL
MUTOA MULTI-USER TELECOMMUNICATION OUTLET
ASSEMBLY
MV MEDIUM VOLTAGE
MWP MEMBRANE WATERPROOFING
N NORTH
N2 NITROGEN
N2O NITROGEN OXIDE
N & D NAIL & DISC
N-G NEUTRAL TO GROUND
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEUT NEUTRAL
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO. NOS NUMBER, NUMBERS
NOM NOMINAL
NPRN NEOPRENE
NPW NONPOTABLE WATER
NRS
NRS
NONRISING STEM
NS NEAR SIDE
NST NONSLIP TREAD
NTS NOT TO SCALE
02 MEDICAL OXYGEN
O TO O OUT TO OUT
O.F. OUTSIDE FACE
OA OVERALL, OUTSIDE AIR
OC ON CENTER
OCPD OVER CURRENT PROTECTOR SERVICE
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OH OVERHEAD
OP OUTLET PROTECTION
OPNG OPENING
OPP OPPOSITE
OS&Y OUTSIDE SCREW AND YOKE
OSP OUTSIDE PLANT
OVHD OVERHEAD
ABBREVIATIONS
FDN FOUNDATION
FDR FEEDER
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FES FLARED END SECTION
FFE FINISH FLOOR ELEVATION
FGL FIBERGLASS
FH FIRE HOSE
FHC FIRE HOSE CABINET
FHYD FIRE HYDRANT
FIG. FIGURE
FIN FL EL FINISH FLOOR ELEVATION
FIN. FINISH
FL FLOOR, FLASHING
FLA FULL LOAD AMPERAGE
FLC FULL LOAD CURRENT
FLEX. FLEXIBLE
FLG FLANGE
FLSH FLASHING
FLUOR FLUORESCENT
FM FLOW METER
FMC FLEXIBLE METAL CONDUIT
FO FIBER OPTIC
FOB FACE OF BRICK, FRONT OF BUILDING
FOR FUEL-OIL RETURN
FOS FUEL-OIL SUPPLY
FOV FUEL-OIL VENT
FPM FEET PER MINUTE
FR FRAME, FROM
FRICT FRICTION
FRT FIRE RETARDANT TREATED
FRZR FREEZER
FS FAR SIDE, FULL SIZE, FLOW SWITCH, FLOOR SINK,
FUSE SIZE
FSCP FLAME SAFEGUARD CONTROL PANEL
FSS FUSED SAFETY SWITCH
FT FOOT
FTG FOOTING
FUR FURRED, FURRING
FURN FURNISH
FUT FUTURE
FVNR FULL VOLTAGE NON-REVERSING
FWC FABRIC WALL COVERING
FWP FABRIC WRAPPED PANEL
FXTR FIXTURE
ºF DEGREES FAHRENHEIT
G GAS MAIN OR SERVICE LINE, NATURAL GAS PIPE
GA GAGE, GAUGE
GAL GALLON
GALV GALVANIZE, GALVANIZED
GC GROUND COUNTERPOISE
GCMU GLAZED CONCRETE MASONRY UNIT
GDR GUARDRAIL
GEN GENERATOR
GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GFE GOVERNMENT FURNISHED EQUIPMENT
GFECI GOVERNMENT FURNISHED EQUIPMENT
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GFI GROUND FAULT INTERRUPTER
GFM GOVERNMENT FURNISHED MATERIAL
GHZ GIGAHERTZ
GI GALVANIZED IRON
GL GLASS
GND GROUND
GOVT GOVERNMENT
GPH GALLON PER HOUR
GPM GALLONS PER MINUTE
GR GRADE
GRAD GRADUATED
GRL GRILLE
GRS GALVANIZED RIGID STEEL
GRT GROUT
GSU GLAZED STRUCTURAL UNITS
GT GLASS TILE
GTB GROUND TERMINAL BOX
GTV GATE VALVE
GV GAS VALVE
GVL GRAVEL
GWB GYPSUM WALLBOARD
GYP GYPSUM
H HIGH
H.I.D HIGH-INTENSITY DISCHARGE
HB HOSE BIB
HBD HARDBOARD
HC HANDICAPPED, HORIZONTAL CROSS CONNECT
HD HEAD, HEAT DEFLECTOR
HDPE HIGH DENSITY POLYETHYLENE
HDR HANDRAIL
HDW HARDWARE
HDWD HARDWOOD
HDWL HEADWALL
HGR HANGER
HGT HEIGHT
HH HANDHOLE
HM HOLLOW METAL
HOA HAND-OFF AUTOMATIC
HORIZ HORIZONTAL
HP HORSEPOWER, HEAT PUMP
HPF HIGH POWER FACTOR
HPS HIGH-PRESSURE SODIUM, HIGH-PRESSURE STEAM
HPT HIGH POINT
HR HOUR
HS HORIZONTAL SLOT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE, HEATING-VENTILATING UNIT
HW DOMESTIC HOT WATER
HWC DOMESTIC HOT WATER CIRCULATING
HWL HIGH-WATER LINE
HYD HYDRANT
Hz HERTZ
I INTERCOM
IC INTERRUPTING CAPACITY, INTERMEDIATE CROSS
CONNECT
ID INSIDE DIAMETER
IEEE THE INSTITUTE OF ELECTRICAL AND ELECTRONICS
ENGINEERS
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IN. INCH
INCAND INCANDESCENT
INCL INCLUSIVE
INCR INCREMENT
IND INDUCTION
INFL INFLUENT
INSTL INSTALL, INSTALLATION
INSUL INSULATION, INSULATED, INSULATOR, INSULATING
INT INTEGRATED, INTERIOR
INTMD INTERMEDIATE
INV INVERT, INVERSE
IP IRON PIN, STORM DRAIN INLET PROTECTION,
INTERNET PROTOCOL
IPF IRON PIN FOUND, IRON PIPE FOUND
IR IRRIGATION
ISOL ISOLATOR
J JOULE, JUNCTION BOX
JB JUNCTION BOX
JC JANITOR'S CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
K KEY OPERATED, KIP
KCM THOUSAND CIRCULAR MILS
KCP KEENE'S CEMENT PILASTER
kg KILOGRAM kg/s KILOGRAM PER SECOND
ABBREVIATIONS
CNDCT CONDUCTIVE
CNDS CONDENSATE, CONDUITS
CO CLEANOUT, COUNTY
CO2 CARBON DIOXIDE
COL COLUMN
COMB. COMBINATION
COMM COMMUNICATION
COMP COMPRESSION, COMPRESSED
CONC CONCRETE
COND CONDUCTOR, CONDUCTIVE, CONDENSER
CONN CONNECT, CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUATION
CONTR CONTRACT, CONTRACTOR
COORD COORDINATE
COP COPPER
COR CORNER
CORR CORRIDOR, CORRUGATED
COV COVER
CP CEMENT PILASTER, CONDENSATE PUMP
CPT CARPET
CR CEILING REGISTER, HOT-CONDENSER WATER
CONTROL RELAY
CSD CELLULAR STEEL DECK
CT CERAMIC TILE, CURRENT TRANSFORMER
CTR CENTER
CTRL CONTROL
CTSK COUNTERSINK
CTWT COUNTERWEIGHT
CU CUBIC, COPPER
CULV CULVERT
CV CONVERTER, CHECK VALVE
CW DOMESTIC COLD WATER
CWB CAPILLARY WATER BARRIER
ºC DEGREES CELSIUS
D DEPTH, DEGREE, OF CURVE, DIMMER SWITCH,
DRAINLINE, MOUNTED IN DUCT
DB DRY BULB, DIRECT BURIAL DUCT, DEEP BANK,
DECIBELS, DEED BOOK, DRAINAGE BASIN
DBL DOUBLE
DC DIRECT CURRENT
DEC DECIDUOUS
DEFL DEFLECT, DEFLECTION
DEG DEGREE
DEM DEMOUNTABLE
DEPR DEPRESSED
DEPT DEPARTMENT
DET DETAIL / DETAILS
DF DRINKING FOUNTAIN
DH DUCT HEATER, DOOR HOLDER
DI DROP INLET, DUCTILE IRON, DEIONIZED WATER
DIA DIAMETER
DIAG DIAGRAM, DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIP. DUCTILE IRON PIPE
DIR DIRECTION, DIRECT, DEIONIZED WATER RETURN
DISC. DISCONNECT
DISCH DISCHARGE
DISP DISPENSER
DIST DISTRIBUTION, DISTANCE
DIV DIVISION
DK DECK
DL DEAD LOAD
DMH DROP MANHOLE
DML DEMOLITION, DEMOLISH
DMPR DAMPER
DN DOWN
DP DISTRIBUTION PANEL
DR DOOR, DRIVE
DS DOWNSPOUT, DRIP STATION, DIGESTED SLUDGE,
DISCONNECT SWITCH
DSD DUCT SMOKE DETECTOR
DTWH DUAL TEMP WALL HYDRANT
DUP DUPLICATE
DV DRAIN VALVE
DVTL DOVETAIL
DW DUMBWAITER, DISHWASHER
DWD DRINKING WATER DISPENSER
DWEL DWELLING
DWG DRAWING
DWLS DOWELS
DWV DRAIN WASTE AND VENT
DX DUPLEX, DIRECT EXPANSION,
E EAST, EMERGENCY (CIRCUIT), ELECTRIC,
ELECTRICAL
E TO E END TO END
E.A.T ENTERING AIR TEMPERATURE
E.W.T ENTERING WATER TEMPERATURE
EA EACH
EC EMPTY CONDUIT, ELECTRICAL CONTRACTOR
ECB ENCLOSED CIRCUIT BREAKER
ECL EMERGENCY CRITICAL LIGHTING
ECMT ENCASEMENT
ECP EMERGENCY CRITICAL POWER
EDB ELECTRIC DUCT BANK
EES EARTH ELECTRODE SYSTEM
EF EACH FACE
EFF EFFLUENT
EG ELECTRIC GROUND
EGB ELECTRIC GROUND BUS
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR, ELEVATION
ELL EMERGENCY LIFE SAFETY LIGHTING
ELP EMERGENCY LIFE SAFETY POWER
EM EXPANDED METAL
EMER EMERGENCY
EMF WALK-OFF ENTRY MAT
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSE, ENCLOSURE
ENG ENGINE
ENGR ENGINEER
ENT ENTERING
ENTR ENTRANCE
EOL END OF LINE
EP EXPLOSION-PROOF, EDGE OF PAVEMENT
EPX EPOXY
EQL EQUAL
EQPT EQUIPMENT
EQUIP EQUIPMENT
ER EXISTING TO REMAIN
ES EDGE OF SHOULDER
ESMT EASEMENT
EV EVERGREEN
EW EACH WAY, END WALL
EWC ELECTRIC WATER COOLER
EXC EXCAVATE, EXCAVATION
EXH EXHAUST
EXP EXPOSED
EXPN EXPANSION
EXST EXISTING
EXT EXTERIOR, EXTERNAL
EXTN EXTENSION
F FUSED, FAN
F TO F FACE TO FACE
F&T FLOAT AND THERMOSTATIC
FA FIRE ALARM
FAB FABRICATE
FABL FIRE ALARM BELL
FACP FIRE ALARM CONTROL PANEL
fC FOOTCANDLE, FAN COIL UNIT, FACE OF CURB
FCO FLOOR CLEANOUT
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
ABBREVIATIONS
# POUND OR NUMBER
& AND
Ø ROUND (DIAMETER) PHASE
A AMPERE, AIR COMPRESSED AIR
A.C.T ACOUSTICAL CEILING TILE
A/E ARCHITECT / ENGINEER
AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND
TRANSPORTATION OFFICIALS
AB ANCHOR BOLT
ABT ABOUT
ABUT. ABUTMENT
ABV ABOVE
AC ALTERNATING CURRENT, AIR CONDITIONING UNIT,
ACRE, AIR COMPRESSOR
ACCS ACCESSORIES
ACI AMERICAN CONCRETE INSTITUTE
ACM ASBESTOS CONTAINING MATERIAL
ACMU ACOUSTICAL CONCRETE MASONRY UNIT
ACP ASBESTOS CEMENT PIPE, ACOUSTICAL CEILING
PANEL
ACS ACESS, ACCESSIBLE
ACST ACOUSTIC, ACOUSTICAL
ACV ALARM CHECK VALVE
ADA AMERICANS WITH DISABILITY ACT
ADD. ADDITIONAL
ADH ADHESIVE
ADJ ADJUSTABLE, ADJACENT
ADMIN ADMINISTRATIVE
ADO AUTOMATIC DOOR OPENER
AFCI ARC FAULT CIRCUIT INTERRUPTER
AFF ABOVE FINISH FLOOR
AFFF AQUEOUS FILM FORMING FOAM
AFG ABOVE FINISH GRADE
AFMS AIRFLOW MEASURING STATION
AGGR AGGREGATE
AH AIR HANDLING, AIR-HANDLING UNIT
AHR ANCHOR
AIC AMPERE INTERRUPTING CAPACITY
AISI AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AL ALUMINUM
ALT ALTERNATE
AM AMMETER
AMP AMPERE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AO AUTOMATIC OPENER
AP ACCESS PANEL
APPR APPROVED
APROX APPROXIMATE
APS ALARM PRESSURE SWITCH
ARCH ARCHITECT / ARCHITECTURAL
AREMA AMERICAN RAILWAY ENGINEERING AND
MAINTENANCE-OF-WAY ASSOCIATION
ASB ASBESTOS
ASC ABOVE SUSPENDED CEILING
ASPH ASPHALT
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ASYM ASYMMETRICAL
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO. AUTOMATIC
AUX AUXILIARY
AV AIR VENT, AUDIO VISUAL, ALTITUDE VALVE, ACID
VENT
AVG AVERAGE
AW ACID WASTE
AWG AMERICAN WIRE GAUGE
AWS AMERICAN WELDING SOCIETY
AWWA AMERICAN WATER WORKS ASSOCIATION
B BATTERY
B TO B BACK TO BACK
B&B BALL & BURLAP
B.O.W BOTTOM OF WALL
BAL BALANCE
BC BOLT CIRCLE, BOTTOM OF CURB, BARE COPPER
BD BOARD
BDL BUNDLE
BEJ BRICK EXPANSION JOINT
BET. BETWEEN
BF BLIND FLANGE
BG BOTTOM GRILLE
BIM BUILDING INFORMATION MODEL
BITUM BITUMINOUS
BL BUILDING LINE, BASE LINE
BLDG BUILDING
BLK BLOCK, BLOCKING
BLW BELOW
BM BEAM, BENCH MARK, SOIL STABILIZATION BLANKET &
MATTING
BOL BEGINNING OF LINE
BOT BOTTOM
BP BASE PLATE, BACKFLOW PREVENTER, BEARING
PLATE
BR BARE ROOT, BOTTOM REGISTER
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
BU BUILT-UP
BUR BUILT-UP ROOF(ING), BURIED
BW BOTH WAYS
C COURSE, CONVECTOR, CENTER, CONDUIT
C TO C CENTER TO CENTER
C&G CURB & GUTTER
C&R CUT & REPLACE
C.O.G CHANGE OF GRADE
CA COMPRESSED AIR
CAB. CABINET
CANTIL. CANTILEVER
CAP. CAPACITY
CATV CABLE TELEVISION
CB CATCH BASIN, CIRCUIT BREAKER
CCTV CLOSED CAPTION TELEVISION
CD CEILING DIFFUSER, ROCK CHECK DAMN
CE CONSTRUCTION ENTRANCE
CEM CEMENT
CENT. CENTRIFUGAL
CF CELLULAR FLOOR, CUBIC FOOT
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD, CHANGE OF GRADE
CH CABINET HEATER, CHORD
CHAM CHAMFER
CHBD CHALKBOARD
CHEM CHEMICAL
CHIS CHISELED
CI CAST IRON
CIP CAST IN PLACE, CULVERT INLET PROTECTION, CAST
IRON PIPE
CIRC CIRCULAR, CIRCUMFERENCE
CJ CONSTRUCTION JOINT
CKT CIRCUIT
CL CENTER LINE
CLF CHAIN LINK FENCE
CLG CEILING
CLJ CONTROL JOINT
CLO CLOSET
CLOS CLOSURE
CLPR CALIPER
CLR CLEAR
CLSD CEILING LINEAR SLOT DIFFUSER
CLSR CEILING LINEAR SLOT RETURN
CM CENTIMETER
CMP CORRUGATED METAL PIPE
CMPSN COMPOSITION
CMU CONCRETE MASONRY UNITS
CND CONDUIT
Th is d ra w in g ha s be en p re pa re d fo r t he u se o f A E
C O
M ’s c lie nt . I t m ay n ot b e us ed
, m od ifi ed
, r ep ro du ce d or re lie d up on b y th ird p ar tie s, e xc ep t a s ag re ed b y
A E
C O
M o r a s re qu ire d by la w . A
E C
O M a cc ep ts n o re sp on si bi lit y, a nd d en ie s an y lia bi lit y w ha ts oe ve r, to a ny p ar ty th at u se s or re lie s on th is d ra w in g w ith ou t A
E C
O M
’s e xp re ss w rit te n co ns en t.
D o no t s ca le th is d oc um en t.
A ll m ea su re m en ts m us t b e ob ta in ed fr om th e st at ed d im en si on s.
www.aecom.com
1 2 3 4 5
D
C
B
A
6 7
E
F
PROJECT
CLIENT
CONSULTANT
REGISTRATION
PATRICK COUNTY
EDA
106 Rucker Street, Stuart, VA, 24171
10 South Jefferson Street, Suite 1600
540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
100% CONCEPT DESIGN
©2016 AECOM Corporation
11/01/2022
AECOM
PATRICK COUNTY
BUSINESS DEVELOPMENT
CENTER PROJECT
132/136 SLUSHER ST.
STUART, VA
100% CD SUBMITTAL SET01/17/2023 I
I
ABBREVIATIONS
G-002
60691532
COLUMN BUBBLE AND GRIDLINE
SITE ELEVATION LEVEL ELEVATION SPOT ELEVATION
ROOM NAME
ROOM TAG
SPACE NUMBER
FLOOR NUMBER
EL. 15'-6"
KEYNOTE
EL. 52.50'
LEVEL NAME
15'-6"
XX.XXX
N
PLAN NORTH/PROJECT NORTH
SECTION OR
DETAIL TITLE
DRAWING SCALE
REFERENCE LOCATION
AE101
A1
REF
SHEET DRAWN
CALLOUT NUMBER
CALLOUT
BOUNDARY
EXTERIOR ELEVATION REFERENCE INTERIOR ELEVATION REFERENCE
A-101
A1
A1
A1
A1A1 A-101
SIM
REFERENCE
SHEET DRAWN
REFERENCE
SHEET DRAWN
SECTION REFERENCE
A1 A-101
SIM
REFERENCE
SHEET DRAWN
ARROW AND TAIL INDICATE
DIRECTION OF SECTION
BREAKLINE MATCHLINE
MATCH LINE SEE A-101B
POINT OF CONNECTION (NEW TO EXISTING)
POINT BETWEE EXISTING WORK TO
REMAIN AND EXISTING WORK TO REMOVE
PIPE BREAK FOR SINGLE LINE PIPE BREAK FOR DOUBLE LINE
SHEET FOR
CONTINUATION
BUILDING LIMITS OF WORK
LIMITS OF WORK
CIVIL LIMITS OF WORK
LW LW LW
DRAWING REVISION
REVISION NUMBER
LIMITS OF REVISION
BUILDING MATERIALS
EARTH
CRUSHED STONE
CONCRETE
STEEL
CONCRETE MASONRY UNITS
BRICK
ACOUSTICAL TILE
ROUGH WOOD
FINISH WOOD
PLYWOOD
PLASTER OR GWB
BATT INSULATION
RIGID INSULATION
COMPRESSIBLE FILLER
SAND
SHEET FILE DISCIPLINE DESIGNATORS
G- GENERAL - 1
GI GENERAL INFORMATION - 2
H HAZARDOUS MATERIALS - 3
HA ASBESTOS ABATEMENT
V- SURVEY - 4
B- GEOTECHNICAL - 5
BB BORING LOGS
CD CIVIL DEMOLITION - 6
C- CIVIL
CC CIVIL EROSION AND SEDIMENT
CONTROL
AD101A
DISCIPLINE DESIGNATION
(1 OR 2 CHARACTERS)
PLAN SHEET
LEVEL OR FLOOR
A-401
SHEET TYPE
SEQUENCE
DISCIPLINE DESIGNATION
CE CIVIL EXISTING
CS CIVIL SITE
CG CIVIL GRADING
CP CIVIL PAVING
CU CIVIL UTILITIES
LD LANDSCAPE DEMOLITION - 7
L- LANDSCAPE
LS LANDSCAPE SITE
LL LANDSCAPE LIGHTING
LP LANDSCAPE PLANTING
SD STRUCTURAL DEMOLITION - 8
S- STRUCTURAL
SS STRUCTURAL SITE
SB STRUCTURAL SUBSTRUCTURE
SF STRUCTURAL FRAMING
SC STRUCTURAL COMPONENTS
SR STRUCTURAL REINFORCEMENT
AD ARCHITECTURAL DEMOLITION - 10
AS ARCHITECTURAL SITE
AE ARCHITECTURAL ELEMENTS
AI ARCHITECTURAL INTERIORS
AF ARCHITECTURAL FINISHES
ID INTERIORS DEMOLITION - 11
I- INTERIORS
IN INTERIOR DESIGN
IF INTERIOR FURNISHINGS
IG INTERIOR GRAPHICS
QF FOOD SERVICE - 12
FD FIRE PROTECTION DEMOLITION - 13
F- FIRE PROTECTION
FA FIRE ALARM
FX FIRE PROTECTION/SUPPRESSION
PD PLUMBING DEMOLITION - 14
P- PLUMBING
PS PLUMBING SITE
PL PLUMBING FIXTURES
PP PLUMBING PIPING
PQ PLUMBING EQUIPMENT
DQ MATERIAL HANDLING - 15
MD MECHANICAL DEMOLITION - 16
M- MECHANICAL
MH MECHANICAL HVAC
MI MECHANICAL INSTRUMENTATION
MP MECHANICAL PIPING
MS MECHANICAL SITE
MY MECHANICAL HYDRAULIC SYSTEMS
MW MECHANICAL DISTRIBUTED ENERGY
ED ELECTRICAL DEMOLITION - 17
E- ELECTRICAL
ES ELECTRICAL SITE
EI ELECTRICAL INSTRUMENTATION
EL ELECTRICAL LIGHTING
EP ELECTRICAL POWER
ET ELECTRICAL TELECOMMUNICATIONS
EY ELECTRICAL AUXILIARY SYSTEMS
EG ELECTRICAL GROUNDING
TD TELECOMMUNICATIONS DEMOLITION - 18
T- TELECOMMUNICATIONS
TA AUDIO VISUAL
TC CLOCK AND PROGRAM
TI INTERCOM
TM MONITORING
TN DATA NETWORKS
TT TELEPHONE
TY SECURITY
TS SCADA
SHEET TYPE DESIGNATORS
0 GENERAL (SYMBOLS LEGEND, NOTES, ETC.)
1 PLANS (HORIZONTAL VIEWS)
2 ELEVATIONS AND PROFILES (VERTICAL VIEWS)
3 SECTIONS (SECTIONAL VIEWS, CROSS-SECTIONS, ETC.)
4 LARGE SCALE VIEWS (ENLARGED PLANS AND ELEVATIONS)
5 DETAILS
6 SCHEDULES AND DIAGRAMS
7 USER DEFINED
8 USER DEFINED
9 3D REPRESENTATIONS (PERSPECTIVES AND PHOTOGRAPHS)
SHEET NUMBERING
KEY PLAN AREA
SYMBOLOGY
SC STRUCTURAL COMPONENTS
SR STRUCTURAL REINFORCEMENT
A- ARCHITECTURAL
A1 View Name 1/8" = 1'-0"
XX.XXX
B1 A3
B2
Th is d ra w in g ha s be en p re pa re d fo r t he u se o f A E
C O
M ’s c lie nt . I t m ay n ot b e us ed
, m od ifi ed
, r ep ro du ce d or re lie d up on b y th ird p ar tie s, e xc ep t a s ag re ed b y
A E
C O
M o r a s re qu ire d by la w . A
E C
O M a cc ep ts n o re sp on si bi lit y, a nd d en ie s an y lia bi lit y w ha ts oe ve r, to a ny p ar ty th at u se s or re lie s on th is d ra w in g w ith ou t A
E C
O M
’s e xp re ss w rit te n co ns en t.
D o no t s ca le th is d oc um en t.
A ll m ea su re m en ts m us t b e ob ta in ed fr om th e st at ed d im en si on s.
www.aecom.com
1 2 3 4 5
D
C
B
A
6 7
E
F
PROJECT
CLIENT
CONSULTANT
REGISTRATION
PATRICK COUNTY
EDA
106 Rucker Street, Stuart, VA, 24171
10 South Jefferson Street, Suite 1600
540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
100% CONCEPT DESIGN
©2016 AECOM Corporation
11/01/2022
AECOM
PATRICK COUNTY
BUSINESS DEVELOPMENT
CENTER PROJECT
132/136 SLUSHER ST.
STUART, VA
100% CD SUBMITTAL SET01/17/2023 I
I
GENERAL SYMBOLOGY
G-003
CONSTRUCTION TYPE
CONSTRUCTION TYPE IIB (ASSUMED, BASED ON PRESENCE OF UNPROTECTED STEEL BEAMS) PER VCC §602.
OCCUPANCY CLASSIFICATION
THERE IS A CHANGE OF OCCUPANCY ON BOTH FLOORS IN ACCORDANCE WITH VEBC CHAPTER 7.
FIRST FLOOR: THE OLD OCCUPANCY CLASSIFICATION WAS STORAGE (GROUP S-1). THE NEW OCCUPANCY CLASSIFICATION IS
EDUCATIONAL (GROUP E).
THE OCCUPANCY CLASSIFICATION IS EDUCATIONAL (GROUP E) INSTEAD OF INSTITUTIONAL (GROUP I-4) SINCE ALL CARE ROOMS FOR CHILDREN UNDER 2 1/2 YEARS OF AGE ARE PROVIDED WITH EXITS DIRECTLY TO THE EXTERIOR IN ACCORDANCE WITH VCC §308.5.1.
SECOND FLOOR: THE OLD OCCUPANCY CLASSIFICATION WAS MERCANTILE (GROUP M). THE NEW OCCUPANCY CLASSIFICATION IS
BUSINESS (GROUP B).
ALLOWABLE HEIGHT & AREA
BASED ON VEBC TABLE 706.2, THE CHANGE OF OCCUPANCIES FROM MERCANTILE TO BUSINESS AND STORAGE TO EDUCATIONAL DOES NOT CREATE ANY HIGHER HAZARD CATEGORIES. THE HEIGHT AND AREA OF THE EXISTING
BUILDING IS DEEMED ACCEPTABLE IN ACCORDANCE WITH VEBC §706.4.
CAPACITY OF MEANS OF EGRESS
VCC §1005.3
DOORS: 0.2" WIDTH PER PERSON
STAIRS: 0.3" WIDTH PER PERSON
OCCUPANT LOAD
PRIMARY APPLICABLE CRITERIA
FOR REFERENCE ONLY. INFORMATION ON THIS DRAWING IS NOT PART OF THE CONSTRUCTION CONTRACT, AS ALL INFORMATION IS
PRESCRIBED FOR ELSEWHERE.
• 2018 VIRGINIA CONSTRUCTION CODE (VCC), WHICH INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL BUILDING CODE (IBC)
• 2018 VIRGINIA EXISTING BUILDING CODE (VEBC), WHICH INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL EXISTING
BUILDING CODE (IEBC)
• 2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC), WHICH INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL FIRE
CODE (IFC)
• NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018
• NFPA 70, NATIONAL ELECTRICAL CODE, 2017
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2016
INTERIOR FINISH CLASSIFICATIONS
PATRICK COUNTY BUSINESS DEVELOPMENT CENTER: LIFE SAFETY & BUILDING CODE ANALYSIS
NUMBER OF EXITS
VCC §1006
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
GROUP
CORRIDORS AND ENCLOSURE
FOR EXIT ACCESS STAIRWAYS
AND EXIT ACCESS RAMPS
INTERIOR EXIT STAIRWAYS,
INTERIOR EXIT RAMPS AND
EXIT PASSAGEWAYS
ROOMS AND
ENCLOSED SPACES
CLASS A INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX, 0-25, SMOKE DEVELOPED, 0-450 CLASS B INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX, 26-75, SMOKE DEVELOPED, 0-450 CLASS C INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX, 76-200, SMOKE DEVELOPED 0-450
NOTE 1: CARPET AND CARPETLIKE INTERIOR FLOOR FINISHES SHALL COMPLY WITH ASTM D 2859 NOTE 2: FLOOR COVERINGS, OTHER THAN CARPET, SHALL HAVE A MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2
CLASS A, B, OR CCLASS A CLASS A OR B
B (BUSINESS) /
E (EDUCATIONAL) CLASS I OR IINOTE 1 AND 2 NOTE 1 AND 2
SPACE EXITS
PROVIDED
EXITS
REQUIRED
FIRST FLOOR 2 8
VCC TABLE 803.13
PORTABLE FIRE EXTINGUISHERS
MULTI-PURPOSE DRY CHEMICAL (ABC) FIRE EXTINGUISHERS WILL BE PROVIDED IN THE WORK AREA. TRAVEL DISTANCE MUST NOT EXCEED 75 FEET TO THE NEAREST FIRE EXTINGUISHER IN ACCORDANCE WITH NFPA 10 REQUIREMENTS. REFER
TO LIFE SAFETY AND ARCHITECTURE FLOOR PLANS FOR EXACT LOCATIONS.
FIRE PROTECTION SYSTEM
THERE IS NO EXISTING FIRE PROTECTION SYSTEM IN THE BUILDING.
THIS RENOVATION DOES NOT REQUIRE FIRE SUPPRESSION SYSTEMS TO BE PROVIDED PER VCC §903.2.
FIRE ALARM SYSTEM
THERE IS NO EXISTING FIRE ALARM SYSTEM IN THE BUILDING.
A NEW ADDRESSABLE FIRE ALARM SYSTEM IS REQUIRED PER VCC §907.2.3 AND WILL BE PROVIDED ON BOTH FLOORS. THE NEW SYSTEM WILL CONSIST OF A FIRE ALARM CONTROL PANEL, TRANSMISSION EQUIPMENT (DACT), MANUAL PULL STATIONS, COMPLETE SMOKE DETECTION THROUGHOUT, HORN/STROBES, AND A REMOTE ANNUNCIATOR PANEL NEAR
THE MAIN ENTRANCE.
THE NEW FIRE ALARM CONTROL PANEL WILL BE PROVIDED IN THE SECOND FLOOR ELECTRICAL CLOSET.
REFER TO FIRE ALARM (FA) DRAWINGS FOR MORE INFORMATION.
CLASSIFICATION OF WORK
LEVEL 2 ALTERATION AS DEFINED IN VEBC §601.2.
APPLICABLE REQUIREMENTS FOR NEW WORK ARE PRESCRIBED IN VEBC §602 AND §603.
ENCLOSURE PROTECTION AND PENETRATION REQUIREMENTS
OPENING PROTECTION - VCC TABLE 716.1(2)
TYPE OF ASSEMBLY REQUIRED WALL RATING
MINIMUM FIRE DOOR AND
SHUTTER RATING
VCC TABLE 1004.5 (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)
FUNCTION OF SPACE
ASSEMBLY, UNCONCENTRATED (TABLES AND CHAIRS)
OCCUPANT LOAD FACTOR
(ft2 / PERSON)
BUSINESS
DAY CARE
15 NET
150 GROSS
35 NET
FIRE PARTITIONS
(FOR CORRIDOR WALLS)
1 HOUR 20 MINUTES
INCIDENTAL USE
NOT APPLICABLE IN ACCORDANCE WITH VCC TABLE 509
REFER TO LIFE SAFETY FLOOR PLANS FOR CALCULATED OCCUPANT LOAD.
ARRANGEMENT OF MEANS OF EGRESS
BOTH FLOORS MEET THE EXIT REMOTENESS CRITERIA OF VCC §1007.1.1. EXITS MUST BE SEPARATED AT LEAST THE DISTANCE OF ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL BUILDING DIAGONAL DIMENSION. REFER TO LIFE SAFETY FLOOR
PLANS FOR BUILDING DIAGONAL AND AREA SEPARATION DIMENSIONS.
TRAVEL DISTANCE TO AN EXIT (VCC TABLE 1017.2):
BUSINESS (GROUP B) AND EDUCATIONAL (GROUP E) OCCUPANCIES: 200 FT
COMMON PATH OF TRAVEL (VCC TABLE 1006.2.1):
BUSINESS (GROUP B) AND EDUCATIONAL (GROUP E) OCCUPANCIES: 75 FT
DEAD END CORRIDORS (VEBC §705.3.2):
BUSINESS (GROUP B) AND EDUCATIONAL (GROUP E) OCCUPANCIES: 35 FT
SECOND FLOOR 2 3
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS
EXTERIOR WALL FIRE-RESISTANCE RATINGS
BASED ON VEBC TABLE 707.1, THE CHANGE OF OCCUPANCIES FROM MERCANTILE TO BUSINESS AND STORAGE TO EDUCATIONAL DOES NOT CREATE ANY HIGHER HAZARD CATEGORIES. THE EXISTING EXTERIOR WALLS, INCLUDING
OPENINGS, SHALL BE ACCEPTABLE IN ACCORDANCE WITH VEBC §707.3.
MEANS OF EGRESS
BASED ON VEBC TABLE 705.2, THE CHANGE OF OCCUPANCY ON THE SECOND FLOOR FROM MERCANTILE TO BUSINESS DOES NOT CREATE A HIGHER HAZARD CATEGORY. HOWEVER, THE CHANGE OF OCCUPANCY ON THE FIRST FLOOR FROM STORAGE TO EDUCATIONAL CREATES A HIGHER HAZARD CATEGORY. ALL MEANS OF EGRESS PROVISIONS MUST
COMPLY WITH VEBC §705.3.
DUCT SMOKE DETECTION
NOT REQUIRED SINCE ALL PORTIONS OF THE BUILDING ARE PROTECTED BY AREA SMOKE DETECTION IN ACCORDANCE
WITH THE VIRGINIA MECHANICAL CODE §606.2.1 EXCEPTION.
T h is d ra w in g h a s b e e n p re p a re d f o r th e u s e o f A
E C
O M
’s c lie n t.
I t m a y n o t b e u s e d m o d if ie d re p ro d u c e d o r re lie d u p o n b y t h ir d p a rt ie s e x c e p t a s a g re e d b y A
E C
O M o r a s r e q u ir e d b y l a w
A
E C
O M a c c e p ts n o r e s p o n s ib ili ty a n d d e n ie s a n y l ia b ili ty w h a ts o e v e r, t o a n y p a rt y t h a t u s e s o r re lie s o n t h is d ra w in g w it h o u t
A E
C O
M ’s e x p re s s w ri tt e n c o n s e n t.
D o n o t s c a le t h is d o c u m e n t.
A ll m e a s u re m e n ts m u s t b e o b ta in e d f ro m t h e s ta te d d im e n s io n s www.aecom.com
1 2 3 4 5
D
C
B
A
6 7
E
F
PROJECT
CLIENT
CONSULTANT
REGISTRATION
PATRICK COUNTY
EDA
106 Rucker Street, Stuart, VA, 24171
10 South Jefferson Street, Suite 1600
540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
©2016 AECOM Corporation
AECOM
PATRICK COUNTY
BUSINESS DEVELOPMENT
CENTER PROJECT
132/136 SLUSHER ST.
STUART, VA
100% CONSTRUCTION SET01/17/2023 I
LIFE SAFETY AND BUILDING
CODE ANALYSIS
GI001
S SS
UP DN
SMOKE PARTITION
1 HR FIRE BARRIER
LIFE SAFETY LEGEND
DESCRIPTION SYMBOL
FIRE EXTINGUISHER, DRY CHEMICAL
(ABC TYPE), WALL MOUNT
COMMON PATH OF TRAVEL
TRAVEL DISTANCE TO EXIT
DEAD END CORRIDOR DEC
TDE
CPT
E-#
EGRESS COMPONENT
COMPONENT IDENTIFIER
REQUIRED CAPACITY
PROVIDED CAPACITY
KITCHEN
103 VESTIBULE
DIRECTOR'S
OFFICE
MECHANICAL AND
PLUMBING
RECEPTION
TELE/DATA ROOM
STORAGE
RESTROOM
STORAGE
RESTROOM
AFTER SCHOOL
PROGRAM
BREAK AREA
CLASSROOM
CLASSROOM
RESTROOM
RESTROOM
PRINT / COPY/
STORAGE
CAR SEAT
STORAGE
CORRIDOR
CLASSROOM
STORAGE/
FUTURE OFFICE
LAUNDRY
HK CLOSET
ELECTRICAL
CLOSET
CLASSROOM
RESTROOM
RESTROOM
1 2 3 4 5
A
C
F
H
I
M
B
D
E
G
J
K
L
E-1
E-3
E-4
E-5
E-6
E-7
E-8
E-2
CPT(1)
TDE(1)
TDE(2)
B U
IL
D
IN
G D
IA
G
O N
A L
EXIT
S
EPARATIO
N =
8' -
7"
DEC(1)
0.010.01
0.01
0.01
0.01
28.00 USE - IBC
ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT
ROOM
BUSINESS AREAS
DAY CARE
T h is d ra w in g h a s b e e n p re p a re d f o r th e u s e o f A
E C
O M
’s c lie n t.
I t m a y n o t b e u s e d m o d if ie d re p ro d u c e d o r re lie d u p o n b y t h ir d p a rt ie s e x c e p t a s a g re e d b y A
E C
O M o r a s r e q u ir e d b y l a w
A
E C
O M a c c e p ts n o r e s p o n s ib ili ty a n d d e n ie s a n y l ia b ili ty w h a ts o e v e r, t o a n y p a rt y t h a t u s e s o r re lie s o n t h is d ra w in g w it h o u t
A E
C O
M ’s e x p re s s w ri tt e n c o n s e n t.
D o n o t s c a le t h is d o c u m e n t.
A ll m e a s u re m e n ts m u s t b e o b ta in e d f ro m t h e s ta te d d im e n s io n s
4' 2' 0 4' 8'
1/4"=1'-0"
N www.aecom.com
1 2 3 4 5
D
C
B
A
GRAPHIC SCALES
6 7
E
F
PROJECT
CLIENT
CONSULTANT
REGISTRATION
PATRICK COUNTY
EDA
106 Rucker Street, Stuart, VA, 24171
10 South Jefferson Street, Suite 1600
540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
©2016 AECOM Corporation
AECOM
PATRICK COUNTY
BUSINESS DEVELOPMENT
CENTER PROJECT
132/136 SLUSHER ST.
STUART, VA
100% CONSTRUCTION SET01/17/2023 I
FIRST FLOOR LIFE SAFETY PLAN
GI101
60691532
SHEET KEYNOTES:
0.01 PANIC HARDWARE REQUIRED ON DOORS SERVING 50 OR
MORE PEOPLE IN A GROUP E (EDUCATIONAL) OCCUPANCY
PER VCC §1010.1.10.
28.00 AREA SMOKE DETECTION TO BE USED FOR DOOR RELEASE
SERVICE IN ACCORDANCE WITH NFPA 72 §17.7.5.6.1.
GENERAL NOTES THIS SHEET:
A. REFER TO GENERAL SHEETS FOR GENERAL NOTES,
ABBREVIATIONS AND SYMBOL LEGEND.
B. ALL DIMENSIONS SHOWN IN FEET UNLESS NOTED OTHERWISE.
C. LIFE SAFETY DRAWINGS ARE PROVIDED TO CONSOLIDATE LIFE
SAFETY REQUIREMENTS AND INTENDED SOLELY TO
DEMOSTRATE COMPLIANCE WITH APPLICABLE BUILDING CODES.
ALL BUILDING COMPONENTS, MATERIALS, HARDWARE, SIZES,
DIMENSIONS, ETC. ARE INDICATED ELSEWHERE ON THE
CONSTRUCTION DOCUMENTS OF THE APPLICABLE DISCIPLINES.
D. FLOOR AREA VALUES SHOWN MAY DIFFER BETWEEN THE LIFE
SAFETY SHEETS AND OTHER DISCIPLINE SHEETS. FLOOR AREAS
ON THE LIFE SAFETY SHEETS ARE COMPUTED IN ACCORDANCE
WITH APPLICABLE BUILDING CODES.
E. FIRE EXTINGUISHER LOCATIONS ARE SHOWN FOR INFORMATION
ONLY. REFER ARCHITECTURAL DRAWINGS FOR EXACT
LOCATION AND DETAILS.
FIRST FLOOR EGRESS CAPACITY CALCULATION
EXIT
NUMBER
PROVIDED
EGRESS WIDTH
(in)
CAPACITY
FACTOR
(PERSONS / in)
PROVIDED
EGRESS
CAPACITY
(PERSONS)
REQUIRED
EGRESS
CAPACITY
(PERSONS)
E-1 66 0.2 330 28
E-2 38 0.2 190 1
E-3 32 0.2 160 27
E-4 32 0.2 160 12
E-5 32 0.2 160 10
E-6 32 0.2 160 27
E-7 32 0.2 160 14
E-8 32 0.2 160 13
1480 132
FIRST FLOOR TRAVEL DISTANCES
TRAVEL PATH DISTANCE (ft) ALLOWABLE (ft)
CPT(1) 73' 75
DEC(1) 34' 35
TDE(1) 131' 200
TDE(2) 64' 200
1/4" = 1'-0"GI101
1 FIRST FLOOR LIFE SAFETY PLAN
FIRST FLOOR OCCUPANT LOAD CALCULATION
NAME USE GROSS/NET AREA (SF)
OCCUPANT LOAD
FACTOR
(SF/PERSON) OCCUPANT LOAD
CLASSROOM 116 DAY CARE NET 411.3 35 12
CLASSROOM 120 DAY CARE NET 349.8 35 10
CLASSROOM 123 DAY CARE NET 504.3 35 14
CLASSROOM 128 DAY CARE NET 443.2 35 13
AFTER SCHOOL PROGRAM 107 DAY CARE NET 1,727.4 35 49
RECEPTION 101 DAY CARE NET 166.2 35 5
DIRECTORS OFFICE 102 BUSINESS AREAS GROSS 141.2 150 1
BREAK AREA 129 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED
NET 224.5 15 15
KITCHEN 103 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED
NET 132.9 15 9
MECHANICAL/PLUMBING,
TELECOM/DATA, STORAGE, HK,
LAUNDRY, STORAGE
ACCESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
GROSS 827.6 300 3
PRINT / COPY / STORAGE AND
CAR SEAT STORAGE
ACCESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
GROSS 136.0 300 1
5,064.4 132
S SSSMOKE PARTITION
1 HR FIRE BARRIER
LIFE SAFETY LEGEND
DESCRIPTION SYMBOL
FIRE EXTINGUISHER, DRY CHEMICAL
(ABC TYPE), WALL MOUNT
COMMON PATH OF TRAVEL
TRAVEL DISTANCE TO EXIT
DEAD END CORRIDOR DEC
TDE
CPT
E-#
EGRESS COMPONENT
COMPONENT IDENTIFIER
REQUIRED CAPACITY
PROVIDED CAPACITY
1 2 3 4 5
A
C
F
H
I
M
B
D
E
G
J
K
L
DIRECTOR'S
OFFICE
WOMEN
MEN
PRINT / COPY/
STORAGE
HK
FOCUS ROOM
PHONE ROOM
FOCUS ROOM
OPEN COLLAB
MEETING ROOM
CORRIDOR
ELECTRICAL
CLOSET
OPEN OFFICE
OFFICE
OFFICE
CONFERENCE
ROOM
CONFERENCE
ROOM
VESTIBULE
OPEN OFFICE
PRINT / MAIL
BREAK AREA
E-9
E-10
E-11*
S-1
TDE(3)
B U
IL
D
IN
G D
IA
G
O N
A L
4'
6"
E X
IT
S
E P
A R
A T
IO
N
' - 8
CPT(2)
TDE(4)
USE - IBC
ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED
BUSINESS AREAS
T h is d ra w in g h a s b e e n p re p a re d f o r th e u s e o f A
E C
O M
’s c lie n t.
I t m a y n o t b e u s e d m o d if ie d re p ro d u c e d o r re lie d u p o n b y t h ir d p a rt ie s e x c e p t a s a g re e d b y A
E C
O M o r a s r e q u ir e d b y l a w
A
E C
O M a c c e p ts n o r e s p o n s ib ili ty a n d d e n ie s a n y l ia b ili ty w h a ts o e v e r, t o a n y p a rt y t h a t u s e s o r re lie s o n t h is d ra w in g w it h o u t
A E
C O
M ’s e x p re s s w ri tt e n c o n s e n t.
D o n o t s c a le t h is d o c u m e n t.
A ll m e a s u re m e n ts m u s t b e o b ta in e d f ro m t h e s ta te d d im e n s io n s
4' 2' 0 4' 8'
1/4"=1'-0"
N www.aecom.com
1 2 3 4 5
D
C
B
A
GRAPHIC SCALES
6 7
E
F
PROJECT
CLIENT
CONSULTANT
REGISTRATION
PATRICK COUNTY
EDA
106 Rucker Street, Stuart, VA, 24171
10 South Jefferson Street, Suite 1600
540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011
ISSUE/REVISION
KEY PLAN
SHEET NUMBER
SHEET TITLE
PROJECT NUMBER
©2016 AECOM Corporation
AECOM
PATRICK COUNTY
BUSINESS DEVELOPMENT
CENTER PROJECT
132/136 SLUSHER ST.
STUART, VA
100% CONSTRUCTION SET01/17/2023 I
SECOND FLOOR LIFE SAFETY
PLAN
GI102
60691532
SHEET KEYNOTES:
GENERAL NOTES THIS SHEET:
A. REFER TO GENERAL SHEETS FOR GENERAL NOTES,
ABBREVIATIONS AND SYMBOL LEGEND.
B. ALL DIMENSIONS SHOWN IN FEET UNLESS NOTED OTHERWISE.
C. LIFE SAFETY DRAWINGS ARE PROVIDED TO CONSOLIDATE LIFE
SAFETY REQUIREMENTS AND INTENDED SOLELY TO
DEMOSTRATE COMPLIANCE WITH APPLICABLE BUILDING CODES.
ALL BUILDING COMPONENTS, MATERIALS, HARDWARE, SIZES,
DIMENSIONS, ETC. ARE INDICATED ELSEWHERE ON THE
CONSTRUCTION DOCUMENTS OF THE APPLICABLE DISCIPLINES.
D. FLOOR AREA VALUES SHOWN MAY DIFFER BETWEEN THE LIFE
SAFETY SHEETS AND OTHER DISCIPLINE SHEETS. FLOOR AREAS
ON THE LIFE SAFETY SHEETS ARE COMPUTED IN ACCORDANCE
WITH APPLICABLE BUILDING CODES.
E. FIRE EXTINGUISHER LOCATIONS ARE SHOWN FOR INFORMATION
ONLY. REFER ARCHITECTURAL DRAWINGS FOR EXACT
LOCATION AND DETAILS.
SECOND FLOOR EGRESS CAPACITY CALCULATION
EXIT
NUMBER
PROVIDED
EGRESS WIDTH
(in)
CAPACITY
FACTOR
(PERSONS / in)
PROVIDED
EGRESS
CAPACITY
(PERSONS)
REQUIRED
EGRESS
CAPACITY
(PERSONS)
E-9 66 0.2 330 55
E-10 66 0.2 330 55
S-1 45 0.3 150 28
810 138
SECOND FLOOR TRAVEL DISTANCES
TRAVEL PATH DISTANCE (ft) ALLOWABLE (ft)
CPT(2) 33' 75
TDE(3) 112' 200
TDE(4) 56' 200
1/4" = 1'-0"GI102
1 SECOND FLOOR LIFE SAFETY PLAN
SECOND FLOOR OCCUPANT LOAD CALCULATION
NAME AREA (SF) USE GROSS/NET
OCCUPANT LOAD
FACTOR
(SF/PERSON) OCCUPANT LOAD
REST OF FLOOR 5,908.7 BUSINESS AREAS GROSS 150 39
CONFERENCE ROOM 213 301.3 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED
NET 15 20
CONFERENCE ROOM 201 230.5 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED
NET 15 15
MEETING ROOM 204 209.9 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED
NET 15 14
BREAK AREA 214 746.4 ASSEMBLY WITHOUT FIXED SEATS:
UNCONCENTRATED
NET 15 50
7,396.8 138
O E
O E
O E
OE
OE
OE OE
O E
O E
O E
O E
O E
O E
O E
O E
OE
OE
OE
OE
OE
OE
OE
OE
O E
O E
O E
O E
OW OW OW OW OW OW OW OW OW OW OW
O E
O E
O E
O E
O E
OT OT OT OT OT
OT
OT
OT
OT
OT
OT
OT
OT
N3 5°
'15
"E
2.
N3
5°
'15 "E
7.
N54°00'45"W 326.47'
N3 5°
'15
"E
8.
N48°30'42"W 201.53'
N3 5°
'15
"E
6.
S54°00'45"E 61.86'
S55°03'51"E 153.14'
S3 5°
'15
"W
5.
S55°03'45"E 152.48'
S3 5°
'15
"W
9.
N3
5°
'15 "E
0.
N3 5°
'15
"E
9.
(tie line to point, formerly Iron Pipe, passing point @ NE corner of Rucker Street @ 150.35' - See Note)
0' to
W B lue R idg e
St re et
(S ee
N ot e)
"S
LU
SH
ER
S
TR
EE
T
EX
TE
NS
IO
N"
TO
W
N
OF
S
TU
AR
T
DB
P
G.
(F
EE
County Tax Map 4811-(9)--16
COUNTY TAX MAP 4811-(9)--11
0.1401 ACRE
(6,102 SQ. FT.)
132 SLUSHER STREET
COUNTY TAX MAP 4811-(9)--6
0.1659 ACRE
(7,225 SQ. FT.)
136 SLUSHER STREET
R/ W
R/ W
R/ W
R/ W
R/ W
R/ W
R/ W
R/ W
½ " I ro n
Ro d
Se t
PK Nail Found
Concrete Nail Set in Sidewalk
Concrete Nail Set in Sidewalk
¾" P inc hed Pipe
Foun d
½" Ir on
Rod Set po int
(tie line - See Note) pt.
N54
°08 '45
"W 0.
' fr om
1¼ " Ir on Pipe
Fo un d
(ti e lin e
NE
co rn er of R uc ke r S tre et
(ti e lin e) point, formerly Iron Pipe (See Note)
(ti e lin e)
(ti e lin e) found in sidewalk from Punch Hole
pt. N54°08'45"W 0.22'
Sh elt er
Loading Dock
Concrete Pad
Gravel Area
Refer to DB 253 pg. 528 for easement to loading dock
Brick Retaining Wall
Wooden PlantersSidewalk
Broken Asphalt Parking Area
Drainage
Ditch
24" RC Pipe
Invert O ut 1328.12'
24" RC Pipe
Invert O ut 1328.53'
18" CP Pipe
Invert In 1334.00'
24" RC Pipe
Invert In 1336.25'
W at er M et er
Va ult
Block Retaining
Wall
Ut ilit y P ole
Power Pole
Power Pole
Po we r P ole
Power Pole
Power Pole
Overhead E lectric
Overhead Electric
Ov er he ad
El ec tric
UTILITY POLE
Overhead Telephone
Si de wa lk
Sidewalk
Si de wa lk
(N ow o r F or m er ly
E.
E.
S lus he r -
D B p g.
TO
W
N
OF
S
TU
AR
T
' E
AS
EM
EN
T
DB
P
G.
(N ow o r F or m er ly
E.
E.
S lus he r -
D B p g.
OP
EN
E
AS
EM
EN
T
PU
BL
IC
P
AS
SA
GE
DB
P G.
D
B
PG
.2
(tie line - See Note)
R/W
R/W
R/W
R/W
Sewer M anhole
Top 1360.35'
Telephone Pole
Water
Valve
Water
Valve
Water
Valve
Water M eter
Water M eter
Fi be r O pt ic Bo lla rd
Fiber Optic
Bollard
Drop Inlet
24" RC Pipe
18" CP Pipe / 24" RC Pipe (Connected??)
Benchmark
Capped Iro n Rod (VDOT)
ELE = 1334.27'
FINISHED FLOOR ELEVATION:
2ND LEVEL UPPER FLOOR - 1360.30'
FINISHED FLOOR ELEVATIONS:
LOWER FLOOR - 1347.75'
1ST LEVEL UPPER FLOOR - 1358.62'
RU
CK
ER
S
TR
EE
T (T
-1
9)
' R /W
(D B pg . 4
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
W W
W W
W
W
R. LEONARD BOWLING
COUNTY TAX MAP 4811-(9)--12
DEED BOOK 263 PG. 130
ALSO SEE DB 244 PG. 441, DB 244 PG. 439,
DB 200 PG. 688, DB 177 PG. 559
AND DB 163 PG. 91
RYE COVE STREET 30' R/W & VARIABLE R/W
(See Plat Book 1 pg. 2, DB 75 pg. 420, Plat Book 12 pg. 43 and VDOT Project R000-070-101)
SL
US
HE
R
ST
RE
ET
V
AR
IA
BL
E
R/ W
TO
W N
OF
S
TU
AR
T
DB
P G.
(F
EE
W W
W W
W W
W W
W W
W W
W W
W W
W W
TELEPHONE POLE
OT
OT
OTBM-1
1334.27
EP
EP
EP
EP
EP
EP
EP
EP
W
W
W
W
COUNTY TAX MAP 4811-(9)--15
N48°30'42"W 154.75'
CURB INLET
MANHOLE TOP 1340.49'
4" PVC INVERT IN 1339.54'
16" RC PIPE INVERT OUT 1336.92'
W
D
D
SITE PLAN SHEET INDEX:
C-1 TITLE SHEET, EXISTING LAYOUT AND DETAILS
C-2 DEMOLITION PLAN AND DETAILS
C-3 LAYOUT PLAN AND DETAILS
C-4 GRADING AND EROSION AND SEDIMENT CONTROL
PLAN AND DETAILS
C-5 GENERAL NOTES AND DETAILS
SURVEY NOTES:
1. THIS SURVEY WAS PROVIDED BY THE OWNER
2. HORIZONTAL DATUM IS VIRGINIA COORDINATE SYSTEM OF 1983, SOUTH ZONE
3. THIS PLAT OF TOPOGRAPHIC SURVEY FOR ECONOMIC DEVELOPMENT AUTHORITY OF PATRICK COUNTY WAS COMPLETED UNDER THE
DIRECT AND RESPONSIBLE CHARGE OF JOHN D. LEWIS FROM AN ACTUAL GROUND OR AIRBORNE SURVEY MADE UNDER HIS SUPERVISION; THAT THE IMAGERY AND/OR ORIGINAL DATA WAS OBTAINED ON 3/15/2023 AND 3/27/2024: AND THAT THIS PLAT, MAP OR DIGITAL GEOSPATIAL DATA INCLUDING METADATA MEETS MINIMUM ACCURACY STANDARDS UNLESS OTHERWISE NOTED.
4. ALL UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED AS MARKED BY TOWN OF STUART PERSONNEL RESPONDING TO MISS UTILITY TICKET #A308001695-00A TAKEN MARCH 21, 2023 AT 1:29 PM. ALL OTHER UTILITIES WERE REPORTED AS "NO CONFLICT"
6. THIS SURVEY DOES NOT ADDRESS ALL POSSIBLE UNDERGROUND UTILITIES. THE UTILITIES SHOWN HEREON ARE PLOTTED PER VISIBLE EVIDENCE IN THE FIELD. IT IS BE THE RESPONSIBILITY OF THE OWNER/CONTRACTOR TO HAVE UNDERGROUND UTILITIES MARKED PRIOR
TO LAND DISTURBANCE OF ANY KIND.
7. THIS DRAWING WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT AND THEREFORE DOES NOT NECESSARILY INDICATE ALL
ENCUMBRANCES ON THE PROPERTY.
8. THE AREA SHOWN IS LOCATED IN FLOOD HAZARD ZONE 'X' (NON-SHADED) AS INDICATED ON FLOOD INSURANCE RATE MAP BY FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), COMMUNITY PANEL NUMBER PANEL #51141C0169E, DATED REVISED SEPTEMBER 19, 2008.
ZONE 'X' (NON-SHADED) IS DEFINED ON SAID MAPS AS "AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN".
9. SLUSHER STREET AND RUCKER STREET SHOWN HEREON ARE BASED ON FIELD WORK BY T.G. SLUSHER, LS 1362. REFER TO PLAT OF SURVEY FOR TOWN OF STUART FOR "SLUSHER STREET EXTENSION" (NOT OF RECORD) DATED AUGUST 24, 1982, SURVEY NO. 1064, PREPARED BY T.G. SLUSHER. CONTROL POINTS AND COORDINATES WERE PROVIDED TO FORK MOUNTAIN SURVEYING & MAPPING, INC BY T.G. SLUSHER AS MOST OF THE CORNERS FROM HIS 1982 SURVEY AND OTHER ORIGINAL MONUMENTS (NOTED AS POINTS HEREON)
LOCATED BY T.G. SLUSHER ARE OBLITERATED.
ASPHALT PAVING
NOT TO SCALE
PRIME COAT
2" THICK ASPHALT PAVING,
VDOT SM-9.5A
COMPACTED SUBGRADE
NOTES:
1. ALL THICKNESSES AFTER COMPACTION
2. PRIME COAT IS REQUIRED FOR THIS PROJECT
6" (MINIMUM) THICK
AGGREGATE BASE, VDOT 21ANO SCALE
V I C I N I T Y M A P
SITE DATA:
OWNER: ECONOMIC DEVELOPMENT AUTHORITY
OF PATRICK COUNTY
MAILING ADDRESS: 106 RUCKER ST
STUART, VA 24171
SITE ADDRESS: 136 & 132 SLUSHER STREET
STUART, VIRGINIA 24171
(WITHIN TOWN LIMITS)
TAX PARCEL: 4811-9-69 & 4811-9-11
SITE AREA: 0.1659± & 0.1401± ACRES (GIS)
DISTRICT: S4 & S4
FLOOD ZONE DATA: PANEL #51141C0169E
ZONE X
CURRENT USE: VACANT (THRIFT SHOP)
PROPOSED USE: DAY CARE
PARKING INFORMATION:
EXISTING PARKING SPACES: 6 MARKED SPACES TOTAL
NO ADA MARKED
PROPOSED PARKING SPACES: 3 W/ 1 ADA COMPLIANT
DISTURBED AREA: 7,000± SF (0.160± AC)
C-1
SITE
W. BLUE RIDGE ST.
PATRICK CO.
HISTORICAL
SOCIETY
PATRICK CO.
ADMIN.
RU
CK
ER
S
T.
SL
USH
ER
S T.
RYE COVE RD.
N. M
AI
N S
T.
W O
O
D BROTH
ER
S D
R
PARK ST.
ST
AP
LE
S
AV
E.
PATRICK AVE.
STUART
CEMETERY
CAMPBELL BRANCH
0.4 0 M
ILE
TO
R
OUTE
CEDAR
SQUARE
APTS.
STUART
PRES.
CHURCH.
6"
COMPACTED SUBGRADE
COMPACTED VDOT #21A
AGGREGATE
GRAVEL PAVEMENT DETAIL
NOT TO SCALE
NOTES:
1. PROVIDE A TEMPORARY PIPE FROM THE DOWNSPOUT TO THE
HARD SURFACE UNTIL THE SITE IS STABILIZED
2. THE DIMENSIONS MUST BE 34" (L) x 12" (W) X 3" (H)
3. SPLASHBLOCKS ARE NOT REQUIRED WHERE DOWNSPOUT
DISCHARGES ONTO PAVEMENT
BU
IL
D
IN
G
34" SPLASHBLOCK DETAIL
NO SCALE
DOWNSPOUT
TURNOUT
HEAVY-DUTY RUBBER SPLASH BLOCK
GRASS
TOPSOIL
CO
CLEANOUT FLUSH W/
GRADE
SEWER CLEANOUT
NO SCALE
NOTES:
1. AN ISOLATION COUPLING IS REQUIRED ON ALL CLEANOUTS.
CLEANOUT W/ COUNTER-
SUNK BRASS PLUG
ISOLATION COUPLING
4" SDR-26/ SCH 40 PVC
4"WYE…
This is the start of the file's text. The full file is on GovTribe.