60691532_Patrick County Business Development Center_100_ Construction Drawing.pdf

PDF 23 MB Posted

Attached to
IFB #2025-81500-01
Solicitation number
76177
Issued by
Page County, Virginia

About this file

This document is a set of construction drawings for the Patrick County Business Development Center project. The drawings were prepared by an architectural firm and include detailed specifications for the 100% construction design of the new facility. The project is being undertaken by Patrick County, located in Virginia. The drawings provide a comprehensive overview of the proposed building, including site plans, floor plans, elevations, sections, and various design details. No specific information is provided regarding the procurement process, response dates, or award timeline for this construction contract.

The drawings do not contain any details on pricing, set asides, incumbents, funding sources, or other contractual terms. This appears to be a design document rather than a procurement solicitation, so those elements are not included. The drawings focus solely on the technical specifications and design of the proposed Patrick County Business Development Center facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT SITE

JEB STUART HW

Y

W O

O D

BR

O

TH

ER

S

DR

BU

SI

NE

SS

P

AR

K

RD

SL

US

HE

R

ST

Th is d ra w in g ha s be en p re pa re d fo r t he u se o f A E

C O

M ’s c lie nt . I t m ay n ot b e us ed

, m od ifi ed

, r ep ro du ce d or re lie d up on b y th ird p ar tie s, e xc ep t a s ag re ed b y

A E

C O

M o r a s re qu ire d by la w . A

E C

O M a cc ep ts n o re sp on si bi lit y, a nd d en ie s an y lia bi lit y w ha ts oe ve r, to a ny p ar ty th at u se s or re lie s on th is d ra w in g w ith ou t A

E C

O M

’s e xp re ss w rit te n co ns en t.

D o no t s ca le th is d oc um en t.

A ll m ea su re m en ts m us t b e ob ta in ed fr om th e st at ed d im en si on s.

www.aecom.com

1 2 3 4 5

D

C

B

A

6 7

E

F

PROJECT

CLIENT

CONSULTANT

REGISTRATION

PATRICK COUNTY

EDA

106 Rucker Street, Stuart, VA, 24171

10 South Jefferson Street, Suite 1600

540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011

ISSUE/REVISION

KEY PLAN

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

100% CONCEPT DESIGN

©2016 AECOM Corporation

11/01/2022

AECOM

PATRICK COUNTY

BUSINESS DEVELOPMENT

CENTER PROJECT

132/136 SLUSHER ST.

STUART, VA

100% CD SUBMITTAL SET01/17/2023 I

I

COVER SHEET

G-001

60691532

100% CONSTRUCTION DOCUMENT SUBMITTAL

LOCATION MAP

STUART, VIRGINIA

JANUARY 17, 2023

AECOM PROJECT NO. 60691532

N

INDEX OF DRAWINGS

SHEET NUMBER SHEET NAME

MECHANICAL

M-001 MECHANICAL LEGEND AND GENERAL NOTES

MH-101 LOWER LEVEL DUCTWORK PLAN

M-102 UPPER LEVEL HVAC PLAN

M-103 ROOF HVAC PLAN

MP-101 LOWER LEVEL PIPING PLAN

M-301 SECTIONS

M-501 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-701 MECHANICAL CONTROLS

M-702 MECHANICAL CONTROLS

M-703 MECHANICAL CONTROLS

ELECTRICAL

E-001 ELECTRICAL ABBREVIATIONS AND LEGEND

E-002 ELECTRICAL SPECIFICATIONS

EL101A LOWER LEVEL LIGHTING PLAN - AREA A

EL101B LOWER LEVEL LIGHTING PLAN - AREA B

EL102A UPPER LEVEL LIGHTING PLAN - AREA A

EL102B UPPER LEVEL LIGHTING PLAN - AREA B

EP101A LOWER LEVEL POWER PLAN - AREA A

EP101B LOWER LEVEL POWER PLAN - AREA B

EP102A UPPER LEVEL POWER PLAN - AREA A

EP102B UPPER LEVEL POWER PLAN - AREA B

EP103 ROOF POWER PLAN - OVERALL

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-601 ELECTRICAL ONE-LINE DIAGRAM

E-701 ELECTRICAL PANEL SCHEDULES

E-702 ELECTRICAL PANEL SCHEDULES

INDEX OF DRAWINGS

SHEET NUMBER SHEET NAME

A411 LOWER LEVEL - INTERIOR ELEVATIONS

A412 UPPER LEVEL - INTERIOR ELEVATIONS

A511 SECTION DETAILS

A521 CEILING DETAILS

A551 STAIRCASE AND RAMP DETAILS

A552 STAIRCASE AND RAMPS - UPPER LEVEL

A553 EXTERIOR STAIRCASE

A601 PARTITION TYPES

A611 DOOR SCHEDULE & DETAILS

A615 DOOR DETAILS

A621 WINDOW DETAILS

A701 LOWER LEVEL - CASEWORK DETAILS

A702 UPPER LEVEL - CASEWORK DETAILS

A710 ARCHITECTURE SPECIFICATIONS

INTERIORS

IN101 INTERIOR FINISH PLAN - COMPOSITE

IN102 LOWER LEVEL - INTERIOR FINISH PLAN AREA A

IN103 LOWER LEVEL - INTERIOR FINISH PLAN AREA B

IN104 UPPER LEVEL - INTERIOR FINISH PLAN AREA A

IN105 UPPER LEVEL - INTERIOR FINISH PLAN AREA B

IN601 LOWER LEVEL INTERIOR FINISH LEGEND AND ROOM FINISH SCHEDULE

IN602 UPPER LEVEL INTERIOR FINISH LEGEND AND ROOM FINISH SCHEDULE

IF101 FURNITURE PLAN - COMPOSITE

IF102 LOWER LEVEL - FURNITURE PLAN AREA A

IF103 LOWER LEVEL - FURNITURE PLAN AREA B

IF104 UPPER LEVEL - FURNITURE PLAN AREA A

IF105 UPPER LEVEL - FURNITURE PLAN AREA B

IF601 LOWER LEVEL - FURNITURE SCHEDULE

IF602 UPPER LEVEL - FURNITURE SCHEDULE

IF603 UPPER LEVEL - FURNITURE SCHEDULE CONT.

FIRE PROTECTION

FA001 FIRE ALARM GENERAL NOTES AND LEGEND

FA101 FIRST FLOOR FIRE ALARM PLAN

FA102 SECOND FLOOR FIRE ALARM PLAN

FA501 FIRE ALARM DETAILS

FA701 FIRE ALARM SPECIFICATIONS

PLUMBING

P-001 LEGEND AND GENERAL NOTES

PU100 UNDERGROUND PLAN

PL101 LOWER LEVEL SUPPLY PLAN

PW101 LOWER LEVEL WASTE PLAN

P-102 UPPER LEVEL PLAN

P-501 DETAILS

P-601 SCHEDULES AND SPECIFICATIONS

P-901 SUPPLY RISER DIAGRAM

P-902 WASTE RISER DIAGRAM

INDEX OF DRAWINGS

SHEET NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

G-002 ABBREVIATIONS

G-003 GENERAL SYMBOLOGY

GENERAL INFORMATION

GI001 LIFE SAFETY AND BUILDING CODE ANALYSIS

GI101 FIRST FLOOR LIFE SAFETY PLAN

GI102 SECOND FLOOR LIFE SAFETY PLAN

CIVIL

C-1 TITLE SHEET, EXISTING LAYOUT AND DETAILS

C-2 DEMOLITION PLAN AND DETAILS

C-3 LAYOUT PLAN AND DETAILS

C-4 GRADING AND EROSION AND SEDIMENT CONTROL PLAN AND DETAILS

C-5 GENERAL NOTES AND DETAILS

STRUCTURAL

S-001 GENERAL NOTES

S-101 FOUNDATION PLAN - COMPOSITE

S-101A FOUNDATION PLAN - AREA A

S-101B FOUNDATION PLAN - AREA B

S-102 SECOND FLOOR FRAMING PLAN - COMPOSITE

S-102A SECOND FLOOR FRAMING PLAN - AREA A

S-102B SECOND FLOOR FRAMING PLAN - AREA B

S-103 ROOF FRAMING PLAN - COMPOSITE

S-103A ROOF FRAMING PLAN - AREA A

S-103B ROOF FRAMING PLAN - AREA B

S-301 SECTIONS & DETAILS

S-302 SECTIONS & DETAILS

S-501 TYPICAL DETAILS

ARCHITECTURE

AD001 GENERAL DEMOLITION NOTES AND LEGEND

AD101 DEMOLITION FLOOR PLANS - COMPOSITE

AD101A LOWER LEVEL - DEMOLITION FLOOR PLAN AREA A

AD101B LOWER LEVEL - DEMOLITION FLOOR PLAN AREA B

AD102A UPPER LEVEL - DEMOLITION FLOOR PLAN AREA A

AD102B UPPER LEVEL - DEMOLITION FLOOR PLAN AREA B

AD152 UPPER LEVEL - DEMOLITION CEILING PLAN

A001 GENERAL NOTES AND LEGENDS

A101 LOWER LEVEL - NEW WORK FLOOR PLAN - COMPOSITE

A101A LOWER LEVEL - NEW WORK FLOOR PLAN AREA A

A101B LOWER LEVEL - NEW WORK FLOOR PLAN AREA B

A102 UPPER LEVEL - NEW WORK FLOOR PLAN - COMPOSITE

A102A UPPER LEVEL - NEW WORK FLOOR PLAN AREA A

A102B UPPER LEVEL - NEW WORK FLOOR PLAN AREA B

A103 ROOF PLAN

A151 LOWER LEVEL - CEILING PLAN COMPOSITE

A152 UPPER LEVEL - CEILING PLAN COMPOSITE

A201 EXTERIOR ELEVATIONS

A301 BUILDING SECTIONS

A401 ENLARGED PARTIAL PLANS

INDEX OF DRAWINGS

I/R DATE DESCRIPTION

ABBREVIATIONS

YD YARD

YHYD YARD HYDRANT

ABBREVIATIONS

SSMR STANDING SEAM METAL ROOF

SST STAINLESS STEEL

ST STREET, STORY, STEAM, SEDIMENT TRAP, STONE

STA STATION

STD STANDARD

STER STERILIZER

STIF STIFFENER

STIR. STIRRUP

STL STEEL

STOR STORAGE

STP SHIELDED TWISTED PAIR

STR STRAIGHT, STARTER

STRL STRUCTURAL

STRUC STRUCTURE

SUBSTA SUSPENDED

SUP SUPPLY

SURF. SURFACE

SUSP SUSPENDED

SV SHEET VINYL, STEAM VENT

SVCE SERVICE

SW SHORT WAY, SWITCH, SIDEWALK

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYMM SYMMETRICAL

SYS SYSTEM

T TREAD, TOP, TANGENT, TELEPHONE, THICKNESS

T&B TOP AND BOTTOM

T&G TONGUE AND GROVE

T.O.W TOP OF WALL

TAF TOWEL APPLIED FINISH

TBB TELECOMMUNICATIONS BONDING BACKBONE

TBM TEMPORARY BENCH MARK

TC TIME CLOCK, TOP OF CURB

TD TRENCH DRAIN

TDC TURNED DOWN CURB

TEF TELECOMMUNICATIONS ENTRANCE FACILITY

TEL TELEPHONE

TEMP TEMPERATURE, TEMPERED, TEMPORARY

TER TERRAZZO

TERM. TERMINAL

TFE TETRAFLUOROETHYLENE

TG TOP GRILLE

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

THERM. THERMOMETER

THK THICK

THKNS THICKNESS

THR THRESHOLD

TKBD TACKBOARD

TLSD TOP LINEAR SLOT DIFFUSER

TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR

TMV THERMAL MIXING VALVE

TO. TELECOMMUNICATIONS OUTLET

TOC TOP OF CONCRETE

TOF TOP OF FOOTING

TOS TOP OF STEEL

TOT. TOTAL

TP TREE PROTECTION, TOILET PARTITION

TR TOP REGISTER, TOP OF RAIL, TELECOM ROOM

TRANSV TRANSVERSE

TRTD TREATED

TS TEMPERATURE STEEL, TIME SWITCH, TAMPER

SWITCH, TEMPORARY SWITCH, THICKENED SLUDGE,

TEMPORARY SEEDING, TRAVERSE STATION

TSD TEMPORARY SLOPE DRAIN

TSP TWISTED SHIELDED PAIR

TST TWISTED SHIELDED TRIPLE

TSTAT THERMOSTAT

TU TERMINAL UNIT

TV TELEVISION, TELEVISION OUTLET

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYP TYPICAL

U.S. URINAL SCREEN

UC UNDERCUT, UNDERCOUNTER

UF UNDERFLOOR

UFD UNDERFLOOR DUCT

UG UNDERGROUND

UH UNIT HEATER

UHF ULTRAHIGH FREQUENCY

UL UNDERWRITERS LABORATORY

ULT ULTIMATE

UNIF UNIFORM

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTABLE POWER SUPPLY

UR URINAL

UTIL UTILITY

UTP UNSHIELDED TWISTED PAIR

V VOLTAGE, VOLT, VENT, VALVE

VA VOLT-AMPERE

VAC VACUUM VOLTS AC, MEDICAL VACUUM

VAR VOLT-AMPERE REACTIVE

VAV VARIABLE AIR VOLUME

VB VAPOR BARRIER

VC VERTICAL CURVE

VCP VITRIED CLAY PIPE

VCT VINYL COMPOSITION TILE

VD VOLUME DAMPER

VDC VOLTS DC

VEL VELOCITY

VENT VENTILATE / VENTILATION

VERT VERTICAL

VEST VESTIBULE

VFD VARIABLE FREQUENCY DRIVE

VHF VERY HIGH FREQUENCY

VIB VIBRATION

VIF VERIFY IN FIELD

VIS VINYL STAIR TREADS AND RISERS

VLT VAULT

VM VOLTMETER

VOL VOLUME

VR VAPOR RETARDER

VS VERTICAL SLOT

VT VINYL TILE

VTR VENT THRU ROOF

VWC VINYL WALL COVERING

W WEST, WIDTH/WIDE

W/ WITH

W/O WITHOUT

WA WAINSCOT

WAGD WASTE ANESTHESIA DISPOSAL

WAS WASTE ACTIVATED SLUDGE

WB WET BULB, WIND BEAM

WC WATER CLOSET, WALL COVERING, WINDOW

COVERING

WD WOOD, WIDTH

WDO WINDOW

WFD WATER FLOW DETECTOR

WG WALL GUARD, WATER GAGE

WH WALL HYDRANT

WHA WATER HAMMER ARRESTER

WHS WELDED HEAD STUD

WI WROUGHT IRON

WL WIND LOAD, WATER LINE

WM WATER METER

WP WORKING POINT, WATERPROOF

WPF WATERPROOFING

WS WATER SURFACE, WATERSTOP

WST WASTE

WT WEIGHT, WINDOW TREATMENT

WTR WATER

WTS WELDED THREADED STUD

WV WATER VALVE, WOOD VENEER

WWR WELDED WIRE FABRIC (WELDED WIRE

REINFORCEMENT)

XARM CROSS ARM

XFMR TRANSFORMER

XFR TRANSFER

XMIT TRANSMITTER

XP EXPLOSION PROOF

ABBREVIATIONS

OZ OUNCE

P POLE, POWER, PUMP

P.F. POWER FACTOR

P.R.S PRESSURE REDUCING STATION

PA PIPE ANCHOR, PUBLIC ADDRESS

Pa PASCAL

PB PUSH BUTTON, PANEL BOARD, PULL BOX

PC POINT OF CURVE

PCC POINT OF COMPOUND CURVE, PRECAST CONCRETE,

PORTLAND CEMENT CONCRETE

PCP PRECAST CONCRETE PANEL

PCSP PRECAST CONCRETE SANDWICH PANEL

PD PRESSURE DROP

PDS PROTECTED DISTRIBUTION SYSTEM

PDU POWER DISTRIBUTION UNIT

PED PEDESTAL

PEJ PREMOLDED EXPANSION JOINT

PET PROTECTED ENTRANCE TERMINAL

PF POROUS FILL

PG PIPE GUIDE, PAGE, PRESSURE GAUGE

PH PHASE, PENTHOUSE

PHR PREHEAT RETURN

PHS PREHEAT SUPPLY

PI POINT OF INTERSECTION

PIV POST INDICATOR VALVE

PL PLATE, PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLATF PLATFORM

PLF POUNDS PER LINEAR FOOT

PLYWD PLYWOOD

PNL PANEL

PNLBD PANELBOARD

PNT PAINT, PAINTED

POB POINT OF BEGINNING

POL POLISH, POINT ON LINE

PP POWER POLE

PPH POUNDS PER HOUR

PR PAIR

PRC POINT OF REVERSE CURVE

PREFIN PREFINISHED

PRESS. PRESSURE

PRI PRIMARY

PRL PARALLEL

PROP. PROPOSED

PROV PROVIDED

PRV PRESSURE REDUCING VALVE, POWER ROOF

VENTILATION

PS PRESSURE SWITCH, PERMANENT SEEDING, POINT

OF SWITCH

PSC PRESTRESSED CONCRETE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH GAGE

PT POINT OF TANGENT, POTENTIAL TRANSFORMER

PTN PARTITION, PORCELAIN TILE

PVC POINT OF VERTICAL CURVE, POLYVINYL CHLORIDE

PVI POINT OF VERTICAL INTERSECTION

PVMT PAVEMENT

PVR PAVER

PVT POINT OF VERTICAL TANGENT, PRIVATE

PWR POWER

TB PORCELAIN CERAMIC TILE BASE

QT QUARRY TILE

QTZ QUARTZ

R RADIUS, RIGHT, RISER

R/W RIGHT OF WAY

RA RETURN AIR

RAD RADIUS

RAF RAISED ACCESS FLOORING

RAS RESILIENT BASE / RUBBER BASE, RETURN

ACTIVATED SLUDGE

RB RUBBER BASE

RBR RUBBER

RCP REINFORCED CONCRETE PIPE

RCPT RECEPTACLE

RCRC RESINOUS CHEMICAL, RESISTANT COATING

RCRTC RESINOUS CHEMICAL RESISTANT TRAFFIC COATING

RCVG RECEIVING

RCVR RECEIVER

RD ROOF DRAIN, ROAD

RDCR REDUCER

REC RECESS

RECIR RECIRCULATING

RECT RECTANGLE, RECTANGULAR

RED. REDUCING

REF REFERENCE

REFL REFLECTED

REFR REFRIGERATOR

REINF REINFORCE, REINFORCEMENT, REINFORCED

REM REMAINDER

REQD REQUIRED

RESIL RESILIENT

REV REVISION

RF ROOF, RADIO FREQUENCY, RESILIENT FLOOR

RFG ROOFING

RFH ROOF HATCH

RFI RADIO FREQUENCY INTERFERENCE

RL ROOF LEADER, REFRIGERANT LIQUID

RM ROOM

RND ROUND

RO ROUGH OPENING

RPBP REDUCED PRESSURE BACKFLOW PREVENTER

RPM REVOLUTION PER MINUTE

RR RIPRAP, RAILROAD

RS ROLLER SHADE

RTE ROUTE

S SOUTH, SANITARY, SEWER, SPEAKER, SWITCH,

SUPPLY

S/N SOLID NEUTRAL

SA SUPPLY AIR

SAN SANITARY

SCFM STANDARD CUBIC FEET PER MINUTE

SCHED SCHEDULE

SCONC SEALED CONC

SD STORM DRAIN, SMOKE DETECTOR

SDF STATIC DISSIPATIVE FLOORING

SDMH STORM DRAIN MANHOLE

SDT STATIC DISSIPATIVE TILE

SEC SECONDARY

SECT SECTION

SF SILT FENCE, SQUARE FEET

SFM SEWER FORCE MAIN

SFP SPRAYED FIRE PROTECTION

SH SHEET

SHV SHELVING

SIM SIMILAR

SK SKETCH

SLP SLOPE

SMH SEWER MANHOLE

SMR SURFACE METAL RACEWAY

SNT SEALANT

SOG SLAB ON GRADE

SP SPACE, SPACES, STATIC PRESSURE, SERVICE

PROVIDER

SPD STATIC PRESSURE DROP, SURGE PROTECTION

DEVICE

SPEC SPECIFICATIONS

SPKR SPEAKER

SPMR SINGLE-PLY MEMBRANE ROOF

SPR SPRINKLER

SPRT SUPPORT

SPS STATIC PRESSURE SENSOR

SQ SQUARE

SRV SURGE RELIEF VALVE

SS SANITARY SEWER, SOLID SURFACE, SAFETY SWITCH

SSD SUBSURFACE DRAIN, SECONDARY STORM DRAIN

SSK SOIL STACK

ABBREVIATIONS

kHZ KILOHERTZ km KILOMETER kN KILONEWTON

KO KNOCKOUT

kPa KILOPASCAL

KSF KIPS PER SQUARE FOOT

KSI KIPS PER SQUARE INCH

kV KILOVOLT kVA KILOVOLT-AMPERE kVAR KILOVOLT-AMPERE REACTIVE kW KILOWATT kWH KILOWATT HOUR

L LEFT, LENGTH OF CURVE, LONG

L-G LINE TO GROUND

L-L LINE TO LINE

L-N LINE TO NEUTRAL

L.W.T LEAVING WATER TEMPERATURE

LA LIGHTENING ARRESTER

LAB LABORATORY

LAM LAMINATE

LAN LOCAL AREA NETWORK

LAT LATITUDE, LATERAL

LAV LAVATORY

LB POUND

LCG LACING

LCP LIGHTING CONTROL PANEL

LDG LOADING

LED LIGHT EMITTING DIODE

LF LINEAR FOOT, LINEAR FEET

LFMC LIQUID LIGHT FLEXIBLE METAL CONDUIT

LG LENGTH, LONG

LI LONG TIME INSTANTANEOUS

LIQ LIQUID

LKR LOCKER

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LOC LOCATE

LONG. LONGITUDINAL

LP LIQUEFIED PROPANE

LPS LOW PRESSURE SODIUM, LIGHTING PROTECTION

SYSTEM

LPT LOW POINT

LR LONG RADIUS, LINEAR REGISTER

LS LUMP SUM, LIMIT SWITCH, LONG TIME SHORT TIME

LSG LONG TIME SHORT TIME GROUND FAULT

LSI LONG TIME SHORT TIME INSTANTANEOUS

LSIG LONG TIME SHORT TIME INSTANTANEOUS GROUND

FAULT

LT LIGHT

LTG LIGHTING

LV LOW VOLUME

LVR LOUVER

LVT LUXURY VINYL TILE

LW LONG WAY, LIMIT OF WORK

LWC LIGHTWEIGHT CONCRETE

LWL LOW-WATER LINE

lx LUX

M MICROPHONE, MANUAL

m METER

M/G MOTOR GENERATOR

MACH MACHINE

MAG MAGNETIC

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION

MAX MAXIMUM

MBH 1000 BTU PER HOUR

MBR MEMBER

MC MAIN CROSS CONNECT

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCCB MOTOR CASE CIRCUIT BREAKER

MCOV MAXIMUM CONTINUOUS OPERATING VOLTAGE

MCP MOTOR CIRCUIT PROTECTOR

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MEMB MEMBRANE

MER MAIN EQUIPMENT ROOM

MET. METAL

MFR MANUFACTURER

MGD MILLION GALLONS PER DAY

MH MANHOLE, MOUNTING HEIGHT, METAL HALIDE

MHz MEGAHERTZ

MID MIDDLE

MIN MINIMUM

MISC MISCELLANEOUS

MJ MECHANICAL JOINT

MK MARK

MKBD MARKER BOARD

MLO MAIN LUGS ONLY

mm MILLIMETERS

MO MASONRY OPENING

MON MONUMENT

MOV METAL OXIDE VARISTOR

MP MEDIUM PRESSURE

MPa MEGAPASCAL

MPH MILES PER HOUR

MR MOP RECEPTOR, MOISTURE RESISTANT

MSL MEAN SEA LEVEL

MT MOUNT

MTD MOUNTED

MTG MOUNTING

MTR MOTOR

MTZ MOTORIZED

MU MULCHING

MUL MULLION

MUTCO MANUAL OF UNIFORM TRAFFIC CONTROL

MUTOA MULTI-USER TELECOMMUNICATION OUTLET

ASSEMBLY

MV MEDIUM VOLTAGE

MWP MEMBRANE WATERPROOFING

N NORTH

N2 NITROGEN

N2O NITROGEN OXIDE

N & D NAIL & DISC

N-G NEUTRAL TO GROUND

N.C. NORMALLY CLOSED

N.O. NORMALLY OPEN

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEUT NEUTRAL

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO. NOS NUMBER, NUMBERS

NOM NOMINAL

NPRN NEOPRENE

NPW NONPOTABLE WATER

NRS

NRS

NONRISING STEM

NS NEAR SIDE

NST NONSLIP TREAD

NTS NOT TO SCALE

02 MEDICAL OXYGEN

O TO O OUT TO OUT

O.F. OUTSIDE FACE

OA OVERALL, OUTSIDE AIR

OC ON CENTER

OCPD OVER CURRENT PROTECTOR SERVICE

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OH OVERHEAD

OP OUTLET PROTECTION

OPNG OPENING

OPP OPPOSITE

OS&Y OUTSIDE SCREW AND YOKE

OSP OUTSIDE PLANT

OVHD OVERHEAD

ABBREVIATIONS

FDN FOUNDATION

FDR FEEDER

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FES FLARED END SECTION

FFE FINISH FLOOR ELEVATION

FGL FIBERGLASS

FH FIRE HOSE

FHC FIRE HOSE CABINET

FHYD FIRE HYDRANT

FIG. FIGURE

FIN FL EL FINISH FLOOR ELEVATION

FIN. FINISH

FL FLOOR, FLASHING

FLA FULL LOAD AMPERAGE

FLC FULL LOAD CURRENT

FLEX. FLEXIBLE

FLG FLANGE

FLSH FLASHING

FLUOR FLUORESCENT

FM FLOW METER

FMC FLEXIBLE METAL CONDUIT

FO FIBER OPTIC

FOB FACE OF BRICK, FRONT OF BUILDING

FOR FUEL-OIL RETURN

FOS FUEL-OIL SUPPLY

FOV FUEL-OIL VENT

FPM FEET PER MINUTE

FR FRAME, FROM

FRICT FRICTION

FRT FIRE RETARDANT TREATED

FRZR FREEZER

FS FAR SIDE, FULL SIZE, FLOW SWITCH, FLOOR SINK,

FUSE SIZE

FSCP FLAME SAFEGUARD CONTROL PANEL

FSS FUSED SAFETY SWITCH

FT FOOT

FTG FOOTING

FUR FURRED, FURRING

FURN FURNISH

FUT FUTURE

FVNR FULL VOLTAGE NON-REVERSING

FWC FABRIC WALL COVERING

FWP FABRIC WRAPPED PANEL

FXTR FIXTURE

ºF DEGREES FAHRENHEIT

G GAS MAIN OR SERVICE LINE, NATURAL GAS PIPE

GA GAGE, GAUGE

GAL GALLON

GALV GALVANIZE, GALVANIZED

GC GROUND COUNTERPOISE

GCMU GLAZED CONCRETE MASONRY UNIT

GDR GUARDRAIL

GEN GENERATOR

GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED

GFE GOVERNMENT FURNISHED EQUIPMENT

GFECI GOVERNMENT FURNISHED EQUIPMENT

CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED

GFI GROUND FAULT INTERRUPTER

GFM GOVERNMENT FURNISHED MATERIAL

GHZ GIGAHERTZ

GI GALVANIZED IRON

GL GLASS

GND GROUND

GOVT GOVERNMENT

GPH GALLON PER HOUR

GPM GALLONS PER MINUTE

GR GRADE

GRAD GRADUATED

GRL GRILLE

GRS GALVANIZED RIGID STEEL

GRT GROUT

GSU GLAZED STRUCTURAL UNITS

GT GLASS TILE

GTB GROUND TERMINAL BOX

GTV GATE VALVE

GV GAS VALVE

GVL GRAVEL

GWB GYPSUM WALLBOARD

GYP GYPSUM

H HIGH

H.I.D HIGH-INTENSITY DISCHARGE

HB HOSE BIB

HBD HARDBOARD

HC HANDICAPPED, HORIZONTAL CROSS CONNECT

HD HEAD, HEAT DEFLECTOR

HDPE HIGH DENSITY POLYETHYLENE

HDR HANDRAIL

HDW HARDWARE

HDWD HARDWOOD

HDWL HEADWALL

HGR HANGER

HGT HEIGHT

HH HANDHOLE

HM HOLLOW METAL

HOA HAND-OFF AUTOMATIC

HORIZ HORIZONTAL

HP HORSEPOWER, HEAT PUMP

HPF HIGH POWER FACTOR

HPS HIGH-PRESSURE SODIUM, HIGH-PRESSURE STEAM

HPT HIGH POINT

HR HOUR

HS HORIZONTAL SLOT

HTG HEATING

HTR HEATER

HV HIGH VOLTAGE, HEATING-VENTILATING UNIT

HW DOMESTIC HOT WATER

HWC DOMESTIC HOT WATER CIRCULATING

HWL HIGH-WATER LINE

HYD HYDRANT

Hz HERTZ

I INTERCOM

IC INTERRUPTING CAPACITY, INTERMEDIATE CROSS

CONNECT

ID INSIDE DIAMETER

IEEE THE INSTITUTE OF ELECTRICAL AND ELECTRONICS

ENGINEERS

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

IN. INCH

INCAND INCANDESCENT

INCL INCLUSIVE

INCR INCREMENT

IND INDUCTION

INFL INFLUENT

INSTL INSTALL, INSTALLATION

INSUL INSULATION, INSULATED, INSULATOR, INSULATING

INT INTEGRATED, INTERIOR

INTMD INTERMEDIATE

INV INVERT, INVERSE

IP IRON PIN, STORM DRAIN INLET PROTECTION,

INTERNET PROTOCOL

IPF IRON PIN FOUND, IRON PIPE FOUND

IR IRRIGATION

ISOL ISOLATOR

J JOULE, JUNCTION BOX

JB JUNCTION BOX

JC JANITOR'S CLOSET

JCT JUNCTION

JST JOIST

JT JOINT

K KEY OPERATED, KIP

KCM THOUSAND CIRCULAR MILS

KCP KEENE'S CEMENT PILASTER

kg KILOGRAM kg/s KILOGRAM PER SECOND

ABBREVIATIONS

CNDCT CONDUCTIVE

CNDS CONDENSATE, CONDUITS

CO CLEANOUT, COUNTY

CO2 CARBON DIOXIDE

COL COLUMN

COMB. COMBINATION

COMM COMMUNICATION

COMP COMPRESSION, COMPRESSED

CONC CONCRETE

COND CONDUCTOR, CONDUCTIVE, CONDENSER

CONN CONNECT, CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS, CONTINUATION

CONTR CONTRACT, CONTRACTOR

COORD COORDINATE

COP COPPER

COR CORNER

CORR CORRIDOR, CORRUGATED

COV COVER

CP CEMENT PILASTER, CONDENSATE PUMP

CPT CARPET

CR CEILING REGISTER, HOT-CONDENSER WATER

CONTROL RELAY

CSD CELLULAR STEEL DECK

CT CERAMIC TILE, CURRENT TRANSFORMER

CTR CENTER

CTRL CONTROL

CTSK COUNTERSINK

CTWT COUNTERWEIGHT

CU CUBIC, COPPER

CULV CULVERT

CV CONVERTER, CHECK VALVE

CW DOMESTIC COLD WATER

CWB CAPILLARY WATER BARRIER

ºC DEGREES CELSIUS

D DEPTH, DEGREE, OF CURVE, DIMMER SWITCH,

DRAINLINE, MOUNTED IN DUCT

DB DRY BULB, DIRECT BURIAL DUCT, DEEP BANK,

DECIBELS, DEED BOOK, DRAINAGE BASIN

DBL DOUBLE

DC DIRECT CURRENT

DEC DECIDUOUS

DEFL DEFLECT, DEFLECTION

DEG DEGREE

DEM DEMOUNTABLE

DEPR DEPRESSED

DEPT DEPARTMENT

DET DETAIL / DETAILS

DF DRINKING FOUNTAIN

DH DUCT HEATER, DOOR HOLDER

DI DROP INLET, DUCTILE IRON, DEIONIZED WATER

DIA DIAMETER

DIAG DIAGRAM, DIAGONAL

DIFF DIFFUSER

DIM DIMENSION

DIP. DUCTILE IRON PIPE

DIR DIRECTION, DIRECT, DEIONIZED WATER RETURN

DISC. DISCONNECT

DISCH DISCHARGE

DISP DISPENSER

DIST DISTRIBUTION, DISTANCE

DIV DIVISION

DK DECK

DL DEAD LOAD

DMH DROP MANHOLE

DML DEMOLITION, DEMOLISH

DMPR DAMPER

DN DOWN

DP DISTRIBUTION PANEL

DR DOOR, DRIVE

DS DOWNSPOUT, DRIP STATION, DIGESTED SLUDGE,

DISCONNECT SWITCH

DSD DUCT SMOKE DETECTOR

DTWH DUAL TEMP WALL HYDRANT

DUP DUPLICATE

DV DRAIN VALVE

DVTL DOVETAIL

DW DUMBWAITER, DISHWASHER

DWD DRINKING WATER DISPENSER

DWEL DWELLING

DWG DRAWING

DWLS DOWELS

DWV DRAIN WASTE AND VENT

DX DUPLEX, DIRECT EXPANSION,

E EAST, EMERGENCY (CIRCUIT), ELECTRIC,

ELECTRICAL

E TO E END TO END

E.A.T ENTERING AIR TEMPERATURE

E.W.T ENTERING WATER TEMPERATURE

EA EACH

EC EMPTY CONDUIT, ELECTRICAL CONTRACTOR

ECB ENCLOSED CIRCUIT BREAKER

ECL EMERGENCY CRITICAL LIGHTING

ECMT ENCASEMENT

ECP EMERGENCY CRITICAL POWER

EDB ELECTRIC DUCT BANK

EES EARTH ELECTRODE SYSTEM

EF EACH FACE

EFF EFFLUENT

EG ELECTRIC GROUND

EGB ELECTRIC GROUND BUS

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR, ELEVATION

ELL EMERGENCY LIFE SAFETY LIGHTING

ELP EMERGENCY LIFE SAFETY POWER

EM EXPANDED METAL

EMER EMERGENCY

EMF WALK-OFF ENTRY MAT

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSE, ENCLOSURE

ENG ENGINE

ENGR ENGINEER

ENT ENTERING

ENTR ENTRANCE

EOL END OF LINE

EP EXPLOSION-PROOF, EDGE OF PAVEMENT

EPX EPOXY

EQL EQUAL

EQPT EQUIPMENT

EQUIP EQUIPMENT

ER EXISTING TO REMAIN

ES EDGE OF SHOULDER

ESMT EASEMENT

EV EVERGREEN

EW EACH WAY, END WALL

EWC ELECTRIC WATER COOLER

EXC EXCAVATE, EXCAVATION

EXH EXHAUST

EXP EXPOSED

EXPN EXPANSION

EXST EXISTING

EXT EXTERIOR, EXTERNAL

EXTN EXTENSION

F FUSED, FAN

F TO F FACE TO FACE

F&T FLOAT AND THERMOSTATIC

FA FIRE ALARM

FAB FABRICATE

FABL FIRE ALARM BELL

FACP FIRE ALARM CONTROL PANEL

fC FOOTCANDLE, FAN COIL UNIT, FACE OF CURB

FCO FLOOR CLEANOUT

FD FLOOR DRAIN, FIRE DAMPER

FDC FIRE DEPARTMENT CONNECTION

ABBREVIATIONS

# POUND OR NUMBER

& AND

Ø ROUND (DIAMETER) PHASE

A AMPERE, AIR COMPRESSED AIR

A.C.T ACOUSTICAL CEILING TILE

A/E ARCHITECT / ENGINEER

AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND

TRANSPORTATION OFFICIALS

AB ANCHOR BOLT

ABT ABOUT

ABUT. ABUTMENT

ABV ABOVE

AC ALTERNATING CURRENT, AIR CONDITIONING UNIT,

ACRE, AIR COMPRESSOR

ACCS ACCESSORIES

ACI AMERICAN CONCRETE INSTITUTE

ACM ASBESTOS CONTAINING MATERIAL

ACMU ACOUSTICAL CONCRETE MASONRY UNIT

ACP ASBESTOS CEMENT PIPE, ACOUSTICAL CEILING

PANEL

ACS ACESS, ACCESSIBLE

ACST ACOUSTIC, ACOUSTICAL

ACV ALARM CHECK VALVE

ADA AMERICANS WITH DISABILITY ACT

ADD. ADDITIONAL

ADH ADHESIVE

ADJ ADJUSTABLE, ADJACENT

ADMIN ADMINISTRATIVE

ADO AUTOMATIC DOOR OPENER

AFCI ARC FAULT CIRCUIT INTERRUPTER

AFF ABOVE FINISH FLOOR

AFFF AQUEOUS FILM FORMING FOAM

AFG ABOVE FINISH GRADE

AFMS AIRFLOW MEASURING STATION

AGGR AGGREGATE

AH AIR HANDLING, AIR-HANDLING UNIT

AHR ANCHOR

AIC AMPERE INTERRUPTING CAPACITY

AISI AMERICAN INSTITUTE OF STEEL CONSTRUCTION

AL ALUMINUM

ALT ALTERNATE

AM AMMETER

AMP AMPERE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AO AUTOMATIC OPENER

AP ACCESS PANEL

APPR APPROVED

APROX APPROXIMATE

APS ALARM PRESSURE SWITCH

ARCH ARCHITECT / ARCHITECTURAL

AREMA AMERICAN RAILWAY ENGINEERING AND

MAINTENANCE-OF-WAY ASSOCIATION

ASB ASBESTOS

ASC ABOVE SUSPENDED CEILING

ASPH ASPHALT

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

ASYM ASYMMETRICAL

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO. AUTOMATIC

AUX AUXILIARY

AV AIR VENT, AUDIO VISUAL, ALTITUDE VALVE, ACID

VENT

AVG AVERAGE

AW ACID WASTE

AWG AMERICAN WIRE GAUGE

AWS AMERICAN WELDING SOCIETY

AWWA AMERICAN WATER WORKS ASSOCIATION

B BATTERY

B TO B BACK TO BACK

B&B BALL & BURLAP

B.O.W BOTTOM OF WALL

BAL BALANCE

BC BOLT CIRCLE, BOTTOM OF CURB, BARE COPPER

BD BOARD

BDL BUNDLE

BEJ BRICK EXPANSION JOINT

BET. BETWEEN

BF BLIND FLANGE

BG BOTTOM GRILLE

BIM BUILDING INFORMATION MODEL

BITUM BITUMINOUS

BL BUILDING LINE, BASE LINE

BLDG BUILDING

BLK BLOCK, BLOCKING

BLW BELOW

BM BEAM, BENCH MARK, SOIL STABILIZATION BLANKET &

MATTING

BOL BEGINNING OF LINE

BOT BOTTOM

BP BASE PLATE, BACKFLOW PREVENTER, BEARING

PLATE

BR BARE ROOT, BOTTOM REGISTER

BRG BEARING

BRK BRICK

BRKT BRACKET

BSMT BASEMENT

BTU BRITISH THERMAL UNIT

BTUH BTU PER HOUR

BU BUILT-UP

BUR BUILT-UP ROOF(ING), BURIED

BW BOTH WAYS

C COURSE, CONVECTOR, CENTER, CONDUIT

C TO C CENTER TO CENTER

C&G CURB & GUTTER

C&R CUT & REPLACE

C.O.G CHANGE OF GRADE

CA COMPRESSED AIR

CAB. CABINET

CANTIL. CANTILEVER

CAP. CAPACITY

CATV CABLE TELEVISION

CB CATCH BASIN, CIRCUIT BREAKER

CCTV CLOSED CAPTION TELEVISION

CD CEILING DIFFUSER, ROCK CHECK DAMN

CE CONSTRUCTION ENTRANCE

CEM CEMENT

CENT. CENTRIFUGAL

CF CELLULAR FLOOR, CUBIC FOOT

CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CFM CUBIC FEET PER MINUTE

CFS CUBIC FEET PER SECOND

CG CORNER GUARD, CHANGE OF GRADE

CH CABINET HEATER, CHORD

CHAM CHAMFER

CHBD CHALKBOARD

CHEM CHEMICAL

CHIS CHISELED

CI CAST IRON

CIP CAST IN PLACE, CULVERT INLET PROTECTION, CAST

IRON PIPE

CIRC CIRCULAR, CIRCUMFERENCE

CJ CONSTRUCTION JOINT

CKT CIRCUIT

CL CENTER LINE

CLF CHAIN LINK FENCE

CLG CEILING

CLJ CONTROL JOINT

CLO CLOSET

CLOS CLOSURE

CLPR CALIPER

CLR CLEAR

CLSD CEILING LINEAR SLOT DIFFUSER

CLSR CEILING LINEAR SLOT RETURN

CM CENTIMETER

CMP CORRUGATED METAL PIPE

CMPSN COMPOSITION

CMU CONCRETE MASONRY UNITS

CND CONDUIT

Th is d ra w in g ha s be en p re pa re d fo r t he u se o f A E

C O

M ’s c lie nt . I t m ay n ot b e us ed

, m od ifi ed

, r ep ro du ce d or re lie d up on b y th ird p ar tie s, e xc ep t a s ag re ed b y

A E

C O

M o r a s re qu ire d by la w . A

E C

O M a cc ep ts n o re sp on si bi lit y, a nd d en ie s an y lia bi lit y w ha ts oe ve r, to a ny p ar ty th at u se s or re lie s on th is d ra w in g w ith ou t A

E C

O M

’s e xp re ss w rit te n co ns en t.

D o no t s ca le th is d oc um en t.

A ll m ea su re m en ts m us t b e ob ta in ed fr om th e st at ed d im en si on s.

www.aecom.com

1 2 3 4 5

D

C

B

A

6 7

E

F

PROJECT

CLIENT

CONSULTANT

REGISTRATION

PATRICK COUNTY

EDA

106 Rucker Street, Stuart, VA, 24171

10 South Jefferson Street, Suite 1600

540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011

ISSUE/REVISION

KEY PLAN

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

100% CONCEPT DESIGN

©2016 AECOM Corporation

11/01/2022

AECOM

PATRICK COUNTY

BUSINESS DEVELOPMENT

CENTER PROJECT

132/136 SLUSHER ST.

STUART, VA

100% CD SUBMITTAL SET01/17/2023 I

I

ABBREVIATIONS

G-002

60691532

COLUMN BUBBLE AND GRIDLINE

SITE ELEVATION LEVEL ELEVATION SPOT ELEVATION

ROOM NAME

ROOM TAG

SPACE NUMBER

FLOOR NUMBER

EL. 15'-6"

KEYNOTE

EL. 52.50'

LEVEL NAME

15'-6"

XX.XXX

N

PLAN NORTH/PROJECT NORTH

SECTION OR

DETAIL TITLE

DRAWING SCALE

REFERENCE LOCATION

AE101

A1

REF

SHEET DRAWN

CALLOUT NUMBER

CALLOUT

BOUNDARY

EXTERIOR ELEVATION REFERENCE INTERIOR ELEVATION REFERENCE

A-101

A1

A1

A1

A1A1 A-101

SIM

REFERENCE

SHEET DRAWN

REFERENCE

SHEET DRAWN

SECTION REFERENCE

A1 A-101

SIM

REFERENCE

SHEET DRAWN

ARROW AND TAIL INDICATE

DIRECTION OF SECTION

BREAKLINE MATCHLINE

MATCH LINE SEE A-101B

POINT OF CONNECTION (NEW TO EXISTING)

POINT BETWEE EXISTING WORK TO

REMAIN AND EXISTING WORK TO REMOVE

PIPE BREAK FOR SINGLE LINE PIPE BREAK FOR DOUBLE LINE

SHEET FOR

CONTINUATION

BUILDING LIMITS OF WORK

LIMITS OF WORK

CIVIL LIMITS OF WORK

LW LW LW

DRAWING REVISION

REVISION NUMBER

LIMITS OF REVISION

BUILDING MATERIALS

EARTH

CRUSHED STONE

CONCRETE

STEEL

CONCRETE MASONRY UNITS

BRICK

ACOUSTICAL TILE

ROUGH WOOD

FINISH WOOD

PLYWOOD

PLASTER OR GWB

BATT INSULATION

RIGID INSULATION

COMPRESSIBLE FILLER

SAND

SHEET FILE DISCIPLINE DESIGNATORS

G- GENERAL - 1

GI GENERAL INFORMATION - 2

H HAZARDOUS MATERIALS - 3

HA ASBESTOS ABATEMENT

V- SURVEY - 4

B- GEOTECHNICAL - 5

BB BORING LOGS

CD CIVIL DEMOLITION - 6

C- CIVIL

CC CIVIL EROSION AND SEDIMENT

CONTROL

AD101A

DISCIPLINE DESIGNATION

(1 OR 2 CHARACTERS)

PLAN SHEET

LEVEL OR FLOOR

A-401

SHEET TYPE

SEQUENCE

DISCIPLINE DESIGNATION

CE CIVIL EXISTING

CS CIVIL SITE

CG CIVIL GRADING

CP CIVIL PAVING

CU CIVIL UTILITIES

LD LANDSCAPE DEMOLITION - 7

L- LANDSCAPE

LS LANDSCAPE SITE

LL LANDSCAPE LIGHTING

LP LANDSCAPE PLANTING

SD STRUCTURAL DEMOLITION - 8

S- STRUCTURAL

SS STRUCTURAL SITE

SB STRUCTURAL SUBSTRUCTURE

SF STRUCTURAL FRAMING

SC STRUCTURAL COMPONENTS

SR STRUCTURAL REINFORCEMENT

AD ARCHITECTURAL DEMOLITION - 10

AS ARCHITECTURAL SITE

AE ARCHITECTURAL ELEMENTS

AI ARCHITECTURAL INTERIORS

AF ARCHITECTURAL FINISHES

ID INTERIORS DEMOLITION - 11

I- INTERIORS

IN INTERIOR DESIGN

IF INTERIOR FURNISHINGS

IG INTERIOR GRAPHICS

QF FOOD SERVICE - 12

FD FIRE PROTECTION DEMOLITION - 13

F- FIRE PROTECTION

FA FIRE ALARM

FX FIRE PROTECTION/SUPPRESSION

PD PLUMBING DEMOLITION - 14

P- PLUMBING

PS PLUMBING SITE

PL PLUMBING FIXTURES

PP PLUMBING PIPING

PQ PLUMBING EQUIPMENT

DQ MATERIAL HANDLING - 15

MD MECHANICAL DEMOLITION - 16

M- MECHANICAL

MH MECHANICAL HVAC

MI MECHANICAL INSTRUMENTATION

MP MECHANICAL PIPING

MS MECHANICAL SITE

MY MECHANICAL HYDRAULIC SYSTEMS

MW MECHANICAL DISTRIBUTED ENERGY

ED ELECTRICAL DEMOLITION - 17

E- ELECTRICAL

ES ELECTRICAL SITE

EI ELECTRICAL INSTRUMENTATION

EL ELECTRICAL LIGHTING

EP ELECTRICAL POWER

ET ELECTRICAL TELECOMMUNICATIONS

EY ELECTRICAL AUXILIARY SYSTEMS

EG ELECTRICAL GROUNDING

TD TELECOMMUNICATIONS DEMOLITION - 18

T- TELECOMMUNICATIONS

TA AUDIO VISUAL

TC CLOCK AND PROGRAM

TI INTERCOM

TM MONITORING

TN DATA NETWORKS

TT TELEPHONE

TY SECURITY

TS SCADA

SHEET TYPE DESIGNATORS

0 GENERAL (SYMBOLS LEGEND, NOTES, ETC.)

1 PLANS (HORIZONTAL VIEWS)

2 ELEVATIONS AND PROFILES (VERTICAL VIEWS)

3 SECTIONS (SECTIONAL VIEWS, CROSS-SECTIONS, ETC.)

4 LARGE SCALE VIEWS (ENLARGED PLANS AND ELEVATIONS)

5 DETAILS

6 SCHEDULES AND DIAGRAMS

7 USER DEFINED

8 USER DEFINED

9 3D REPRESENTATIONS (PERSPECTIVES AND PHOTOGRAPHS)

SHEET NUMBERING

KEY PLAN AREA

SYMBOLOGY

SC STRUCTURAL COMPONENTS

SR STRUCTURAL REINFORCEMENT

A- ARCHITECTURAL

A1 View Name 1/8" = 1'-0"

XX.XXX

B1 A3

B2

Th is d ra w in g ha s be en p re pa re d fo r t he u se o f A E

C O

M ’s c lie nt . I t m ay n ot b e us ed

, m od ifi ed

, r ep ro du ce d or re lie d up on b y th ird p ar tie s, e xc ep t a s ag re ed b y

A E

C O

M o r a s re qu ire d by la w . A

E C

O M a cc ep ts n o re sp on si bi lit y, a nd d en ie s an y lia bi lit y w ha ts oe ve r, to a ny p ar ty th at u se s or re lie s on th is d ra w in g w ith ou t A

E C

O M

’s e xp re ss w rit te n co ns en t.

D o no t s ca le th is d oc um en t.

A ll m ea su re m en ts m us t b e ob ta in ed fr om th e st at ed d im en si on s.

www.aecom.com

1 2 3 4 5

D

C

B

A

6 7

E

F

PROJECT

CLIENT

CONSULTANT

REGISTRATION

PATRICK COUNTY

EDA

106 Rucker Street, Stuart, VA, 24171

10 South Jefferson Street, Suite 1600

540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011

ISSUE/REVISION

KEY PLAN

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

100% CONCEPT DESIGN

©2016 AECOM Corporation

11/01/2022

AECOM

PATRICK COUNTY

BUSINESS DEVELOPMENT

CENTER PROJECT

132/136 SLUSHER ST.

STUART, VA

100% CD SUBMITTAL SET01/17/2023 I

I

GENERAL SYMBOLOGY

G-003

CONSTRUCTION TYPE

CONSTRUCTION TYPE IIB (ASSUMED, BASED ON PRESENCE OF UNPROTECTED STEEL BEAMS) PER VCC §602.

OCCUPANCY CLASSIFICATION

THERE IS A CHANGE OF OCCUPANCY ON BOTH FLOORS IN ACCORDANCE WITH VEBC CHAPTER 7.

FIRST FLOOR: THE OLD OCCUPANCY CLASSIFICATION WAS STORAGE (GROUP S-1). THE NEW OCCUPANCY CLASSIFICATION IS

EDUCATIONAL (GROUP E).

THE OCCUPANCY CLASSIFICATION IS EDUCATIONAL (GROUP E) INSTEAD OF INSTITUTIONAL (GROUP I-4) SINCE ALL CARE ROOMS FOR CHILDREN UNDER 2 1/2 YEARS OF AGE ARE PROVIDED WITH EXITS DIRECTLY TO THE EXTERIOR IN ACCORDANCE WITH VCC §308.5.1.

SECOND FLOOR: THE OLD OCCUPANCY CLASSIFICATION WAS MERCANTILE (GROUP M). THE NEW OCCUPANCY CLASSIFICATION IS

BUSINESS (GROUP B).

ALLOWABLE HEIGHT & AREA

BASED ON VEBC TABLE 706.2, THE CHANGE OF OCCUPANCIES FROM MERCANTILE TO BUSINESS AND STORAGE TO EDUCATIONAL DOES NOT CREATE ANY HIGHER HAZARD CATEGORIES. THE HEIGHT AND AREA OF THE EXISTING

BUILDING IS DEEMED ACCEPTABLE IN ACCORDANCE WITH VEBC §706.4.

CAPACITY OF MEANS OF EGRESS

VCC §1005.3

DOORS: 0.2" WIDTH PER PERSON

STAIRS: 0.3" WIDTH PER PERSON

OCCUPANT LOAD

PRIMARY APPLICABLE CRITERIA

FOR REFERENCE ONLY. INFORMATION ON THIS DRAWING IS NOT PART OF THE CONSTRUCTION CONTRACT, AS ALL INFORMATION IS

PRESCRIBED FOR ELSEWHERE.

• 2018 VIRGINIA CONSTRUCTION CODE (VCC), WHICH INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL BUILDING CODE (IBC)

• 2018 VIRGINIA EXISTING BUILDING CODE (VEBC), WHICH INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL EXISTING

BUILDING CODE (IEBC)

• 2018 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC), WHICH INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL FIRE

CODE (IFC)

• NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018

• NFPA 70, NATIONAL ELECTRICAL CODE, 2017

• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2016

INTERIOR FINISH CLASSIFICATIONS

PATRICK COUNTY BUSINESS DEVELOPMENT CENTER: LIFE SAFETY & BUILDING CODE ANALYSIS

NUMBER OF EXITS

VCC §1006

INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY

GROUP

CORRIDORS AND ENCLOSURE

FOR EXIT ACCESS STAIRWAYS

AND EXIT ACCESS RAMPS

INTERIOR EXIT STAIRWAYS,

INTERIOR EXIT RAMPS AND

EXIT PASSAGEWAYS

ROOMS AND

ENCLOSED SPACES

CLASS A INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX, 0-25, SMOKE DEVELOPED, 0-450 CLASS B INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX, 26-75, SMOKE DEVELOPED, 0-450 CLASS C INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX, 76-200, SMOKE DEVELOPED 0-450

NOTE 1: CARPET AND CARPETLIKE INTERIOR FLOOR FINISHES SHALL COMPLY WITH ASTM D 2859 NOTE 2: FLOOR COVERINGS, OTHER THAN CARPET, SHALL HAVE A MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2

CLASS A, B, OR CCLASS A CLASS A OR B

B (BUSINESS) /

E (EDUCATIONAL) CLASS I OR IINOTE 1 AND 2 NOTE 1 AND 2

SPACE EXITS

PROVIDED

EXITS

REQUIRED

FIRST FLOOR 2 8

VCC TABLE 803.13

PORTABLE FIRE EXTINGUISHERS

MULTI-PURPOSE DRY CHEMICAL (ABC) FIRE EXTINGUISHERS WILL BE PROVIDED IN THE WORK AREA. TRAVEL DISTANCE MUST NOT EXCEED 75 FEET TO THE NEAREST FIRE EXTINGUISHER IN ACCORDANCE WITH NFPA 10 REQUIREMENTS. REFER

TO LIFE SAFETY AND ARCHITECTURE FLOOR PLANS FOR EXACT LOCATIONS.

FIRE PROTECTION SYSTEM

THERE IS NO EXISTING FIRE PROTECTION SYSTEM IN THE BUILDING.

THIS RENOVATION DOES NOT REQUIRE FIRE SUPPRESSION SYSTEMS TO BE PROVIDED PER VCC §903.2.

FIRE ALARM SYSTEM

THERE IS NO EXISTING FIRE ALARM SYSTEM IN THE BUILDING.

A NEW ADDRESSABLE FIRE ALARM SYSTEM IS REQUIRED PER VCC §907.2.3 AND WILL BE PROVIDED ON BOTH FLOORS. THE NEW SYSTEM WILL CONSIST OF A FIRE ALARM CONTROL PANEL, TRANSMISSION EQUIPMENT (DACT), MANUAL PULL STATIONS, COMPLETE SMOKE DETECTION THROUGHOUT, HORN/STROBES, AND A REMOTE ANNUNCIATOR PANEL NEAR

THE MAIN ENTRANCE.

THE NEW FIRE ALARM CONTROL PANEL WILL BE PROVIDED IN THE SECOND FLOOR ELECTRICAL CLOSET.

REFER TO FIRE ALARM (FA) DRAWINGS FOR MORE INFORMATION.

CLASSIFICATION OF WORK

LEVEL 2 ALTERATION AS DEFINED IN VEBC §601.2.

APPLICABLE REQUIREMENTS FOR NEW WORK ARE PRESCRIBED IN VEBC §602 AND §603.

ENCLOSURE PROTECTION AND PENETRATION REQUIREMENTS

OPENING PROTECTION - VCC TABLE 716.1(2)

TYPE OF ASSEMBLY REQUIRED WALL RATING

MINIMUM FIRE DOOR AND

SHUTTER RATING

VCC TABLE 1004.5 (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)

FUNCTION OF SPACE

ASSEMBLY, UNCONCENTRATED (TABLES AND CHAIRS)

OCCUPANT LOAD FACTOR

(ft2 / PERSON)

BUSINESS

DAY CARE

15 NET

150 GROSS

35 NET

FIRE PARTITIONS

(FOR CORRIDOR WALLS)

1 HOUR 20 MINUTES

INCIDENTAL USE

NOT APPLICABLE IN ACCORDANCE WITH VCC TABLE 509

REFER TO LIFE SAFETY FLOOR PLANS FOR CALCULATED OCCUPANT LOAD.

ARRANGEMENT OF MEANS OF EGRESS

BOTH FLOORS MEET THE EXIT REMOTENESS CRITERIA OF VCC §1007.1.1. EXITS MUST BE SEPARATED AT LEAST THE DISTANCE OF ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL BUILDING DIAGONAL DIMENSION. REFER TO LIFE SAFETY FLOOR

PLANS FOR BUILDING DIAGONAL AND AREA SEPARATION DIMENSIONS.

TRAVEL DISTANCE TO AN EXIT (VCC TABLE 1017.2):

BUSINESS (GROUP B) AND EDUCATIONAL (GROUP E) OCCUPANCIES: 200 FT

COMMON PATH OF TRAVEL (VCC TABLE 1006.2.1):

BUSINESS (GROUP B) AND EDUCATIONAL (GROUP E) OCCUPANCIES: 75 FT

DEAD END CORRIDORS (VEBC §705.3.2):

BUSINESS (GROUP B) AND EDUCATIONAL (GROUP E) OCCUPANCIES: 35 FT

SECOND FLOOR 2 3

ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS

EXTERIOR WALL FIRE-RESISTANCE RATINGS

BASED ON VEBC TABLE 707.1, THE CHANGE OF OCCUPANCIES FROM MERCANTILE TO BUSINESS AND STORAGE TO EDUCATIONAL DOES NOT CREATE ANY HIGHER HAZARD CATEGORIES. THE EXISTING EXTERIOR WALLS, INCLUDING

OPENINGS, SHALL BE ACCEPTABLE IN ACCORDANCE WITH VEBC §707.3.

MEANS OF EGRESS

BASED ON VEBC TABLE 705.2, THE CHANGE OF OCCUPANCY ON THE SECOND FLOOR FROM MERCANTILE TO BUSINESS DOES NOT CREATE A HIGHER HAZARD CATEGORY. HOWEVER, THE CHANGE OF OCCUPANCY ON THE FIRST FLOOR FROM STORAGE TO EDUCATIONAL CREATES A HIGHER HAZARD CATEGORY. ALL MEANS OF EGRESS PROVISIONS MUST

COMPLY WITH VEBC §705.3.

DUCT SMOKE DETECTION

NOT REQUIRED SINCE ALL PORTIONS OF THE BUILDING ARE PROTECTED BY AREA SMOKE DETECTION IN ACCORDANCE

WITH THE VIRGINIA MECHANICAL CODE §606.2.1 EXCEPTION.

T h is d ra w in g h a s b e e n p re p a re d f o r th e u s e o f A

E C

O M

’s c lie n t.

I t m a y n o t b e u s e d m o d if ie d re p ro d u c e d o r re lie d u p o n b y t h ir d p a rt ie s e x c e p t a s a g re e d b y A

E C

O M o r a s r e q u ir e d b y l a w

A

E C

O M a c c e p ts n o r e s p o n s ib ili ty a n d d e n ie s a n y l ia b ili ty w h a ts o e v e r, t o a n y p a rt y t h a t u s e s o r re lie s o n t h is d ra w in g w it h o u t

A E

C O

M ’s e x p re s s w ri tt e n c o n s e n t.

D o n o t s c a le t h is d o c u m e n t.

A ll m e a s u re m e n ts m u s t b e o b ta in e d f ro m t h e s ta te d d im e n s io n s www.aecom.com

1 2 3 4 5

D

C

B

A

6 7

E

F

PROJECT

CLIENT

CONSULTANT

REGISTRATION

PATRICK COUNTY

EDA

106 Rucker Street, Stuart, VA, 24171

10 South Jefferson Street, Suite 1600

540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011

ISSUE/REVISION

KEY PLAN

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

©2016 AECOM Corporation

AECOM

PATRICK COUNTY

BUSINESS DEVELOPMENT

CENTER PROJECT

132/136 SLUSHER ST.

STUART, VA

100% CONSTRUCTION SET01/17/2023 I

LIFE SAFETY AND BUILDING

CODE ANALYSIS

GI001

S SS

UP DN

SMOKE PARTITION

1 HR FIRE BARRIER

LIFE SAFETY LEGEND

DESCRIPTION SYMBOL

FIRE EXTINGUISHER, DRY CHEMICAL

(ABC TYPE), WALL MOUNT

COMMON PATH OF TRAVEL

TRAVEL DISTANCE TO EXIT

DEAD END CORRIDOR DEC

TDE

CPT

E-#

EGRESS COMPONENT

COMPONENT IDENTIFIER

REQUIRED CAPACITY

PROVIDED CAPACITY

KITCHEN

103 VESTIBULE

DIRECTOR'S

OFFICE

MECHANICAL AND

PLUMBING

RECEPTION

TELE/DATA ROOM

STORAGE

RESTROOM

STORAGE

RESTROOM

AFTER SCHOOL

PROGRAM

BREAK AREA

CLASSROOM

CLASSROOM

RESTROOM

RESTROOM

PRINT / COPY/

STORAGE

CAR SEAT

STORAGE

CORRIDOR

CLASSROOM

STORAGE/

FUTURE OFFICE

LAUNDRY

HK CLOSET

ELECTRICAL

CLOSET

CLASSROOM

RESTROOM

RESTROOM

1 2 3 4 5

A

C

F

H

I

M

B

D

E

G

J

K

L

E-1

E-3

E-4

E-5

E-6

E-7

E-8

E-2

CPT(1)

TDE(1)

TDE(2)

B U

IL

D

IN

G D

IA

G

O N

A L

EXIT

S

EPARATIO

N =

8' -

7"

DEC(1)

0.010.01

0.01

0.01

0.01

28.00 USE - IBC

ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED

ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT

ROOM

BUSINESS AREAS

DAY CARE

T h is d ra w in g h a s b e e n p re p a re d f o r th e u s e o f A

E C

O M

’s c lie n t.

I t m a y n o t b e u s e d m o d if ie d re p ro d u c e d o r re lie d u p o n b y t h ir d p a rt ie s e x c e p t a s a g re e d b y A

E C

O M o r a s r e q u ir e d b y l a w

A

E C

O M a c c e p ts n o r e s p o n s ib ili ty a n d d e n ie s a n y l ia b ili ty w h a ts o e v e r, t o a n y p a rt y t h a t u s e s o r re lie s o n t h is d ra w in g w it h o u t

A E

C O

M ’s e x p re s s w ri tt e n c o n s e n t.

D o n o t s c a le t h is d o c u m e n t.

A ll m e a s u re m e n ts m u s t b e o b ta in e d f ro m t h e s ta te d d im e n s io n s

4' 2' 0 4' 8'

1/4"=1'-0"

N www.aecom.com

1 2 3 4 5

D

C

B

A

GRAPHIC SCALES

6 7

E

F

PROJECT

CLIENT

CONSULTANT

REGISTRATION

PATRICK COUNTY

EDA

106 Rucker Street, Stuart, VA, 24171

10 South Jefferson Street, Suite 1600

540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011

ISSUE/REVISION

KEY PLAN

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

©2016 AECOM Corporation

AECOM

PATRICK COUNTY

BUSINESS DEVELOPMENT

CENTER PROJECT

132/136 SLUSHER ST.

STUART, VA

100% CONSTRUCTION SET01/17/2023 I

FIRST FLOOR LIFE SAFETY PLAN

GI101

60691532

SHEET KEYNOTES:

0.01 PANIC HARDWARE REQUIRED ON DOORS SERVING 50 OR

MORE PEOPLE IN A GROUP E (EDUCATIONAL) OCCUPANCY

PER VCC §1010.1.10.

28.00 AREA SMOKE DETECTION TO BE USED FOR DOOR RELEASE

SERVICE IN ACCORDANCE WITH NFPA 72 §17.7.5.6.1.

GENERAL NOTES THIS SHEET:

A. REFER TO GENERAL SHEETS FOR GENERAL NOTES,

ABBREVIATIONS AND SYMBOL LEGEND.

B. ALL DIMENSIONS SHOWN IN FEET UNLESS NOTED OTHERWISE.

C. LIFE SAFETY DRAWINGS ARE PROVIDED TO CONSOLIDATE LIFE

SAFETY REQUIREMENTS AND INTENDED SOLELY TO

DEMOSTRATE COMPLIANCE WITH APPLICABLE BUILDING CODES.

ALL BUILDING COMPONENTS, MATERIALS, HARDWARE, SIZES,

DIMENSIONS, ETC. ARE INDICATED ELSEWHERE ON THE

CONSTRUCTION DOCUMENTS OF THE APPLICABLE DISCIPLINES.

D. FLOOR AREA VALUES SHOWN MAY DIFFER BETWEEN THE LIFE

SAFETY SHEETS AND OTHER DISCIPLINE SHEETS. FLOOR AREAS

ON THE LIFE SAFETY SHEETS ARE COMPUTED IN ACCORDANCE

WITH APPLICABLE BUILDING CODES.

E. FIRE EXTINGUISHER LOCATIONS ARE SHOWN FOR INFORMATION

ONLY. REFER ARCHITECTURAL DRAWINGS FOR EXACT

LOCATION AND DETAILS.

FIRST FLOOR EGRESS CAPACITY CALCULATION

EXIT

NUMBER

PROVIDED

EGRESS WIDTH

(in)

CAPACITY

FACTOR

(PERSONS / in)

PROVIDED

EGRESS

CAPACITY

(PERSONS)

REQUIRED

EGRESS

CAPACITY

(PERSONS)

E-1 66 0.2 330 28

E-2 38 0.2 190 1

E-3 32 0.2 160 27

E-4 32 0.2 160 12

E-5 32 0.2 160 10

E-6 32 0.2 160 27

E-7 32 0.2 160 14

E-8 32 0.2 160 13

1480 132

FIRST FLOOR TRAVEL DISTANCES

TRAVEL PATH DISTANCE (ft) ALLOWABLE (ft)

CPT(1) 73' 75

DEC(1) 34' 35

TDE(1) 131' 200

TDE(2) 64' 200

1/4" = 1'-0"GI101

1 FIRST FLOOR LIFE SAFETY PLAN

FIRST FLOOR OCCUPANT LOAD CALCULATION

NAME USE GROSS/NET AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON) OCCUPANT LOAD

CLASSROOM 116 DAY CARE NET 411.3 35 12

CLASSROOM 120 DAY CARE NET 349.8 35 10

CLASSROOM 123 DAY CARE NET 504.3 35 14

CLASSROOM 128 DAY CARE NET 443.2 35 13

AFTER SCHOOL PROGRAM 107 DAY CARE NET 1,727.4 35 49

RECEPTION 101 DAY CARE NET 166.2 35 5

DIRECTORS OFFICE 102 BUSINESS AREAS GROSS 141.2 150 1

BREAK AREA 129 ASSEMBLY WITHOUT FIXED SEATS:

UNCONCENTRATED

NET 224.5 15 15

KITCHEN 103 ASSEMBLY WITHOUT FIXED SEATS:

UNCONCENTRATED

NET 132.9 15 9

MECHANICAL/PLUMBING,

TELECOM/DATA, STORAGE, HK,

LAUNDRY, STORAGE

ACCESSORY STORAGE AREAS,

MECHANICAL EQUIPMENT ROOM

GROSS 827.6 300 3

PRINT / COPY / STORAGE AND

CAR SEAT STORAGE

ACCESSORY STORAGE AREAS,

MECHANICAL EQUIPMENT ROOM

GROSS 136.0 300 1

5,064.4 132

S SSSMOKE PARTITION

1 HR FIRE BARRIER

LIFE SAFETY LEGEND

DESCRIPTION SYMBOL

FIRE EXTINGUISHER, DRY CHEMICAL

(ABC TYPE), WALL MOUNT

COMMON PATH OF TRAVEL

TRAVEL DISTANCE TO EXIT

DEAD END CORRIDOR DEC

TDE

CPT

E-#

EGRESS COMPONENT

COMPONENT IDENTIFIER

REQUIRED CAPACITY

PROVIDED CAPACITY

1 2 3 4 5

A

C

F

H

I

M

B

D

E

G

J

K

L

DIRECTOR'S

OFFICE

WOMEN

MEN

PRINT / COPY/

STORAGE

HK

FOCUS ROOM

PHONE ROOM

FOCUS ROOM

OPEN COLLAB

MEETING ROOM

CORRIDOR

ELECTRICAL

CLOSET

OPEN OFFICE

OFFICE

OFFICE

CONFERENCE

ROOM

CONFERENCE

ROOM

VESTIBULE

OPEN OFFICE

PRINT / MAIL

BREAK AREA

E-9

E-10

E-11*

S-1

TDE(3)

B U

IL

D

IN

G D

IA

G

O N

A L

4'

6"

E X

IT

S

E P

A R

A T

IO

N

' - 8

CPT(2)

TDE(4)

USE - IBC

ASSEMBLY WITHOUT FIXED SEATS: UNCONCENTRATED

BUSINESS AREAS

T h is d ra w in g h a s b e e n p re p a re d f o r th e u s e o f A

E C

O M

’s c lie n t.

I t m a y n o t b e u s e d m o d if ie d re p ro d u c e d o r re lie d u p o n b y t h ir d p a rt ie s e x c e p t a s a g re e d b y A

E C

O M o r a s r e q u ir e d b y l a w

A

E C

O M a c c e p ts n o r e s p o n s ib ili ty a n d d e n ie s a n y l ia b ili ty w h a ts o e v e r, t o a n y p a rt y t h a t u s e s o r re lie s o n t h is d ra w in g w it h o u t

A E

C O

M ’s e x p re s s w ri tt e n c o n s e n t.

D o n o t s c a le t h is d o c u m e n t.

A ll m e a s u re m e n ts m u s t b e o b ta in e d f ro m t h e s ta te d d im e n s io n s

4' 2' 0 4' 8'

1/4"=1'-0"

N www.aecom.com

1 2 3 4 5

D

C

B

A

GRAPHIC SCALES

6 7

E

F

PROJECT

CLIENT

CONSULTANT

REGISTRATION

PATRICK COUNTY

EDA

106 Rucker Street, Stuart, VA, 24171

10 South Jefferson Street, Suite 1600

540.857.3100 tel 540.857.3180 fax Roanoke, Virginia 24011

ISSUE/REVISION

KEY PLAN

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

©2016 AECOM Corporation

AECOM

PATRICK COUNTY

BUSINESS DEVELOPMENT

CENTER PROJECT

132/136 SLUSHER ST.

STUART, VA

100% CONSTRUCTION SET01/17/2023 I

SECOND FLOOR LIFE SAFETY

PLAN

GI102

60691532

SHEET KEYNOTES:

GENERAL NOTES THIS SHEET:

A. REFER TO GENERAL SHEETS FOR GENERAL NOTES,

ABBREVIATIONS AND SYMBOL LEGEND.

B. ALL DIMENSIONS SHOWN IN FEET UNLESS NOTED OTHERWISE.

C. LIFE SAFETY DRAWINGS ARE PROVIDED TO CONSOLIDATE LIFE

SAFETY REQUIREMENTS AND INTENDED SOLELY TO

DEMOSTRATE COMPLIANCE WITH APPLICABLE BUILDING CODES.

ALL BUILDING COMPONENTS, MATERIALS, HARDWARE, SIZES,

DIMENSIONS, ETC. ARE INDICATED ELSEWHERE ON THE

CONSTRUCTION DOCUMENTS OF THE APPLICABLE DISCIPLINES.

D. FLOOR AREA VALUES SHOWN MAY DIFFER BETWEEN THE LIFE

SAFETY SHEETS AND OTHER DISCIPLINE SHEETS. FLOOR AREAS

ON THE LIFE SAFETY SHEETS ARE COMPUTED IN ACCORDANCE

WITH APPLICABLE BUILDING CODES.

E. FIRE EXTINGUISHER LOCATIONS ARE SHOWN FOR INFORMATION

ONLY. REFER ARCHITECTURAL DRAWINGS FOR EXACT

LOCATION AND DETAILS.

SECOND FLOOR EGRESS CAPACITY CALCULATION

EXIT

NUMBER

PROVIDED

EGRESS WIDTH

(in)

CAPACITY

FACTOR

(PERSONS / in)

PROVIDED

EGRESS

CAPACITY

(PERSONS)

REQUIRED

EGRESS

CAPACITY

(PERSONS)

E-9 66 0.2 330 55

E-10 66 0.2 330 55

S-1 45 0.3 150 28

810 138

SECOND FLOOR TRAVEL DISTANCES

TRAVEL PATH DISTANCE (ft) ALLOWABLE (ft)

CPT(2) 33' 75

TDE(3) 112' 200

TDE(4) 56' 200

1/4" = 1'-0"GI102

1 SECOND FLOOR LIFE SAFETY PLAN

SECOND FLOOR OCCUPANT LOAD CALCULATION

NAME AREA (SF) USE GROSS/NET

OCCUPANT LOAD

FACTOR

(SF/PERSON) OCCUPANT LOAD

REST OF FLOOR 5,908.7 BUSINESS AREAS GROSS 150 39

CONFERENCE ROOM 213 301.3 ASSEMBLY WITHOUT FIXED SEATS:

UNCONCENTRATED

NET 15 20

CONFERENCE ROOM 201 230.5 ASSEMBLY WITHOUT FIXED SEATS:

UNCONCENTRATED

NET 15 15

MEETING ROOM 204 209.9 ASSEMBLY WITHOUT FIXED SEATS:

UNCONCENTRATED

NET 15 14

BREAK AREA 214 746.4 ASSEMBLY WITHOUT FIXED SEATS:

UNCONCENTRATED

NET 15 50

7,396.8 138

O E

O E

O E

OE

OE

OE OE

O E

O E

O E

O E

O E

O E

O E

O E

OE

OE

OE

OE

OE

OE

OE

OE

O E

O E

O E

O E

OW OW OW OW OW OW OW OW OW OW OW

O E

O E

O E

O E

O E

OT OT OT OT OT

OT

OT

OT

OT

OT

OT

OT

OT

N3 5°

'15

"E

2.

N3

5°

'15 "E

7.

N54°00'45"W 326.47'

N3 5°

'15

"E

8.

N48°30'42"W 201.53'

N3 5°

'15

"E

6.

S54°00'45"E 61.86'

S55°03'51"E 153.14'

S3 5°

'15

"W

5.

S55°03'45"E 152.48'

S3 5°

'15

"W

9.

N3

5°

'15 "E

0.

N3 5°

'15

"E

9.

(tie line to point, formerly Iron Pipe, passing point @ NE corner of Rucker Street @ 150.35' - See Note)

0' to

W B lue R idg e

St re et

(S ee

N ot e)

"S

LU

SH

ER

S

TR

EE

T

EX

TE

NS

IO

N"

TO

W

N

OF

S

TU

AR

T

DB

P

G.

(F

EE

County Tax Map 4811-(9)--16

COUNTY TAX MAP 4811-(9)--11

0.1401 ACRE

(6,102 SQ. FT.)

132 SLUSHER STREET

COUNTY TAX MAP 4811-(9)--6

0.1659 ACRE

(7,225 SQ. FT.)

136 SLUSHER STREET

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

½ " I ro n

Ro d

Se t

PK Nail Found

Concrete Nail Set in Sidewalk

Concrete Nail Set in Sidewalk

¾" P inc hed Pipe

Foun d

½" Ir on

Rod Set po int

(tie line - See Note) pt.

N54

°08 '45

"W 0.

' fr om

1¼ " Ir on Pipe

Fo un d

(ti e lin e

NE

co rn er of R uc ke r S tre et

(ti e lin e) point, formerly Iron Pipe (See Note)

(ti e lin e)

(ti e lin e) found in sidewalk from Punch Hole

pt. N54°08'45"W 0.22'

Sh elt er

Loading Dock

Concrete Pad

Gravel Area

Refer to DB 253 pg. 528 for easement to loading dock

Brick Retaining Wall

Wooden PlantersSidewalk

Broken Asphalt Parking Area

Drainage

Ditch

24" RC Pipe

Invert O ut 1328.12'

24" RC Pipe

Invert O ut 1328.53'

18" CP Pipe

Invert In 1334.00'

24" RC Pipe

Invert In 1336.25'

W at er M et er

Va ult

Block Retaining

Wall

Ut ilit y P ole

Power Pole

Power Pole

Po we r P ole

Power Pole

Power Pole

Overhead E lectric

Overhead Electric

Ov er he ad

El ec tric

UTILITY POLE

Overhead Telephone

Si de wa lk

Sidewalk

Si de wa lk

(N ow o r F or m er ly

E.

E.

S lus he r -

D B p g.

TO

W

N

OF

S

TU

AR

T

' E

AS

EM

EN

T

DB

P

G.

(N ow o r F or m er ly

E.

E.

S lus he r -

D B p g.

OP

EN

E

AS

EM

EN

T

PU

BL

IC

P

AS

SA

GE

DB

P G.

D

B

PG

.2

(tie line - See Note)

R/W

R/W

R/W

R/W

Sewer M anhole

Top 1360.35'

Telephone Pole

Water

Valve

Water

Valve

Water

Valve

Water M eter

Water M eter

Fi be r O pt ic Bo lla rd

Fiber Optic

Bollard

Drop Inlet

24" RC Pipe

18" CP Pipe / 24" RC Pipe (Connected??)

Benchmark

Capped Iro n Rod (VDOT)

ELE = 1334.27'

FINISHED FLOOR ELEVATION:

2ND LEVEL UPPER FLOOR - 1360.30'

FINISHED FLOOR ELEVATIONS:

LOWER FLOOR - 1347.75'

1ST LEVEL UPPER FLOOR - 1358.62'

RU

CK

ER

S

TR

EE

T (T

-1

9)

' R /W

(D B pg . 4

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

W W

W W

W

W

R. LEONARD BOWLING

COUNTY TAX MAP 4811-(9)--12

DEED BOOK 263 PG. 130

ALSO SEE DB 244 PG. 441, DB 244 PG. 439,

DB 200 PG. 688, DB 177 PG. 559

AND DB 163 PG. 91

RYE COVE STREET 30' R/W & VARIABLE R/W

(See Plat Book 1 pg. 2, DB 75 pg. 420, Plat Book 12 pg. 43 and VDOT Project R000-070-101)

SL

US

HE

R

ST

RE

ET

V

AR

IA

BL

E

R/ W

TO

W N

OF

S

TU

AR

T

DB

P G.

(F

EE

W W

W W

W W

W W

W W

W W

W W

W W

W W

TELEPHONE POLE

OT

OT

OTBM-1

1334.27

EP

EP

EP

EP

EP

EP

EP

EP

W

W

W

W

COUNTY TAX MAP 4811-(9)--15

N48°30'42"W 154.75'

CURB INLET

MANHOLE TOP 1340.49'

4" PVC INVERT IN 1339.54'

16" RC PIPE INVERT OUT 1336.92'

W

D

D

SITE PLAN SHEET INDEX:

C-1 TITLE SHEET, EXISTING LAYOUT AND DETAILS

C-2 DEMOLITION PLAN AND DETAILS

C-3 LAYOUT PLAN AND DETAILS

C-4 GRADING AND EROSION AND SEDIMENT CONTROL

PLAN AND DETAILS

C-5 GENERAL NOTES AND DETAILS

SURVEY NOTES:

1. THIS SURVEY WAS PROVIDED BY THE OWNER

2. HORIZONTAL DATUM IS VIRGINIA COORDINATE SYSTEM OF 1983, SOUTH ZONE

3. THIS PLAT OF TOPOGRAPHIC SURVEY FOR ECONOMIC DEVELOPMENT AUTHORITY OF PATRICK COUNTY WAS COMPLETED UNDER THE

DIRECT AND RESPONSIBLE CHARGE OF JOHN D. LEWIS FROM AN ACTUAL GROUND OR AIRBORNE SURVEY MADE UNDER HIS SUPERVISION; THAT THE IMAGERY AND/OR ORIGINAL DATA WAS OBTAINED ON 3/15/2023 AND 3/27/2024: AND THAT THIS PLAT, MAP OR DIGITAL GEOSPATIAL DATA INCLUDING METADATA MEETS MINIMUM ACCURACY STANDARDS UNLESS OTHERWISE NOTED.

4. ALL UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED AS MARKED BY TOWN OF STUART PERSONNEL RESPONDING TO MISS UTILITY TICKET #A308001695-00A TAKEN MARCH 21, 2023 AT 1:29 PM. ALL OTHER UTILITIES WERE REPORTED AS "NO CONFLICT"

6. THIS SURVEY DOES NOT ADDRESS ALL POSSIBLE UNDERGROUND UTILITIES. THE UTILITIES SHOWN HEREON ARE PLOTTED PER VISIBLE EVIDENCE IN THE FIELD. IT IS BE THE RESPONSIBILITY OF THE OWNER/CONTRACTOR TO HAVE UNDERGROUND UTILITIES MARKED PRIOR

TO LAND DISTURBANCE OF ANY KIND.

7. THIS DRAWING WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT AND THEREFORE DOES NOT NECESSARILY INDICATE ALL

ENCUMBRANCES ON THE PROPERTY.

8. THE AREA SHOWN IS LOCATED IN FLOOD HAZARD ZONE 'X' (NON-SHADED) AS INDICATED ON FLOOD INSURANCE RATE MAP BY FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), COMMUNITY PANEL NUMBER PANEL #51141C0169E, DATED REVISED SEPTEMBER 19, 2008.

ZONE 'X' (NON-SHADED) IS DEFINED ON SAID MAPS AS "AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN".

9. SLUSHER STREET AND RUCKER STREET SHOWN HEREON ARE BASED ON FIELD WORK BY T.G. SLUSHER, LS 1362. REFER TO PLAT OF SURVEY FOR TOWN OF STUART FOR "SLUSHER STREET EXTENSION" (NOT OF RECORD) DATED AUGUST 24, 1982, SURVEY NO. 1064, PREPARED BY T.G. SLUSHER. CONTROL POINTS AND COORDINATES WERE PROVIDED TO FORK MOUNTAIN SURVEYING & MAPPING, INC BY T.G. SLUSHER AS MOST OF THE CORNERS FROM HIS 1982 SURVEY AND OTHER ORIGINAL MONUMENTS (NOTED AS POINTS HEREON)

LOCATED BY T.G. SLUSHER ARE OBLITERATED.

ASPHALT PAVING

NOT TO SCALE

PRIME COAT

2" THICK ASPHALT PAVING,

VDOT SM-9.5A

COMPACTED SUBGRADE

NOTES:

1. ALL THICKNESSES AFTER COMPACTION

2. PRIME COAT IS REQUIRED FOR THIS PROJECT

6" (MINIMUM) THICK

AGGREGATE BASE, VDOT 21ANO SCALE

V I C I N I T Y M A P

SITE DATA:

OWNER: ECONOMIC DEVELOPMENT AUTHORITY

OF PATRICK COUNTY

MAILING ADDRESS: 106 RUCKER ST

STUART, VA 24171

SITE ADDRESS: 136 & 132 SLUSHER STREET

STUART, VIRGINIA 24171

(WITHIN TOWN LIMITS)

TAX PARCEL: 4811-9-69 & 4811-9-11

SITE AREA: 0.1659± & 0.1401± ACRES (GIS)

DISTRICT: S4 & S4

FLOOD ZONE DATA: PANEL #51141C0169E

ZONE X

CURRENT USE: VACANT (THRIFT SHOP)

PROPOSED USE: DAY CARE

PARKING INFORMATION:

EXISTING PARKING SPACES: 6 MARKED SPACES TOTAL

NO ADA MARKED

PROPOSED PARKING SPACES: 3 W/ 1 ADA COMPLIANT

DISTURBED AREA: 7,000± SF (0.160± AC)

C-1

SITE

W. BLUE RIDGE ST.

PATRICK CO.

HISTORICAL

SOCIETY

PATRICK CO.

ADMIN.

RU

CK

ER

S

T.

SL

USH

ER

S T.

RYE COVE RD.

N. M

AI

N S

T.

W O

O

D BROTH

ER

S D

R

PARK ST.

ST

AP

LE

S

AV

E.

PATRICK AVE.

STUART

CEMETERY

CAMPBELL BRANCH

0.4 0 M

ILE

TO

R

OUTE

CEDAR

SQUARE

APTS.

STUART

PRES.

CHURCH.

6"

COMPACTED SUBGRADE

COMPACTED VDOT #21A

AGGREGATE

GRAVEL PAVEMENT DETAIL

NOT TO SCALE

NOTES:

1. PROVIDE A TEMPORARY PIPE FROM THE DOWNSPOUT TO THE

HARD SURFACE UNTIL THE SITE IS STABILIZED

2. THE DIMENSIONS MUST BE 34" (L) x 12" (W) X 3" (H)

3. SPLASHBLOCKS ARE NOT REQUIRED WHERE DOWNSPOUT

DISCHARGES ONTO PAVEMENT

BU

IL

D

IN

G

34" SPLASHBLOCK DETAIL

NO SCALE

DOWNSPOUT

TURNOUT

HEAVY-DUTY RUBBER SPLASH BLOCK

GRASS

TOPSOIL

CO

CLEANOUT FLUSH W/

GRADE

SEWER CLEANOUT

NO SCALE

NOTES:

1. AN ISOLATION COUPLING IS REQUIRED ON ALL CLEANOUTS.

CLEANOUT W/ COUNTER-

SUNK BRASS PLUG

ISOLATION COUPLING

4" SDR-26/ SCH 40 PVC

4"WYE…

This is the start of the file's text. The full file is on GovTribe.