About this file
This file contains approved construction plans for the Davis Technical College Main Building Glazing Replacement project, prepared by the Utah Division of Facilities Construction and Management (DFCM) and Method Studio Inc. The project involves replacing exterior glazing and window systems in select portions of the Main Building, specifically the Hair and Nail Salon Vocational Rooms (CW 7 and SF 8). The base bid improvements include work on the Barlow Building, Allied Health Building, Simmons Building, and Main Building, with Add Alternate 01 addressing exterior glazing removal and replacement with new exterior storefront and curtain wall systems. The project includes delegated design requiring comprehensive engineering analysis and performance requirements by a qualified professional engineer. The construction cost estimate is $265,000.00, and only contractors prequalified under Stage I and currently listed on the DFCM Prequalified Contractors list are eligible to bid on this Stage II invitation to bid.
The approved plans include detailed architectural drawings, exterior elevation sheets, glazing schedules, and construction details dated July 16, 2026, with code compliance review completed by Thomas Peterson on August 25, 2026. Glazing specifications include double-pane insulated glazing with low-E coating (G1), double-pane insulated tempered glazing (G2), and heat-treated insulated glazing (P1). All curtainwall systems require delegated design submittals, and safety glazing must be installed in hazardous locations per IBC 2406.4. The project owner is Davis Technical College located at 550 E 300 S, Kaysville, UT 84037, with contact Bryce Fox serving as the owner's representative and Kelton Berrett as the architect at Method Studio. All work must comply with applicable codes, ordinances, and regulations, and the contractor is responsible for producing a weathertight building and coordinating with mechanical, plumbing, and electrical trades.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 5-3-CS27020-27049220-Approved Specs.pdf | ||
| 3-C-DFCM Health Insurance Statement of Compliance Form, Revised 7.28.25.docx | DOCX document | |
| 4-1-CS27020-27049220-Solicitation.docx | DOCX document | |
| 1-A-DFCM General Conditions August 2020-Clean rev 07122023.pdf | ||
| 2-B-Subcontractors List Form Instructions-7.1.2021.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADD ALTERNATES
1. EXTERIOR GLAZING
Remove and replace existing exterior glazing systems with new exterior storefront and curtain wall systems in the following locations:
- Main Building - CW 7 & SF 8 (Hair and Nail Salon Vocational Rooms)
NOTE:
DELEGATED DESIGN: DESIGN ALUMINUM-FRAMED SYSTEMS AND
ATTACHMENT TO STRUCTURE, INCLUDING COMPREHENSIVE
ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER,
USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED.
BASE BID IMPROVEMENTS
BARLOW BUILDING
ALLIED HEALTH BUILDING
SIMMONS BUILDING
MAIN BUILDING
ADD ALTERNATE 01
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
E
D
C
B
A
E
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
DFCM APPROVAL STAMP
G000
COVER
SHEET
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
Davis Tech Main Building Glazing 07/16/2026 owner davis technical college 550 E 300 S kaysville, ut 84037
(801) 593-2500 contact: bryce fox architect method studio 360 w aspen ave salt lake city, ut 84101
(801) 532-4422 contact: kelton berrett
DFCM Project No. 27049220
VICINITY MAP
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
THOMAS PETERSON
08/25/2026
MATERIAL LEGEND
EARTH (EXISTING)
EARTH (BACKFILL)
DRAINAGE FILL
COMPACTED FILL
CONCRETE
CAST-IN-PLACE
CONCRETE
PRECAST
BRICK
CONCRETE MASONRY
UNIT
GROUT
STEEL
ALUMINUM
CONTINUOUS WOOD
SHEATHING
INTERMITTENT WOOD
BLOCKING
WOOD FINISH
HARDBOARD
PARTICLE BOARD
BATT INSULATION
LOOSE FILL INSULATION
RIGID INSULATION
FIRE SPRAY
GYPSUM BOARD
ARCHITECTURE SYMBOLS
A102
SHEET TYPE
DISCIPLINE
SHEET NUMBER SEQUENCE
XX
000x
F1
R1
WALL FUNCTION
CORE MATERIAL
CORE SIZE (ROUNDED)
MODIFIER
101M
AWS STANDARD CASEWORK TYPE
MODIFIED CASEWORK TYPE
REFER TO CASEWORK DESIGN SERIES (CDS) OF
THE ARCHITECTURAL WOODWORK STANDARDS
(AWS) FOR A FULL DESCRIPTION OF CASEWORK
TYPES
100' - 0"
MAIN LEVEL
LEVEL NAME
LEVEL ELEVATION
AE000
1 Ref
Re f
1 Ref
Re f
AE000
1 Ref
Re f
1 Ref
Re f
SHEET NUMBER
POSITION ON SHEET
SHEET NUMBER
POSITION ON SHEET
DRAWING NUMBER
VIEW NAME
DRAWING SCALE
ORIGINAL SOURCE OF DETAIL
A101
A101
POSITION ON SHEET
SHEET NUMBER
SHEET NUMBER
VIEW DIRECTION
POSITION ON SHEET
A1
AE101
SIM
A1
AE101
SIM
A1
AE101
SIM
VIEW DIRECTION
POSITION ON SHEET
SHEET NUMBER
ROOM NUMBER
ROOM AREA
01A
SIGN TYPE
SIGN NUMBER
VIEW DIRECTION
POSITION ON SHEET
SHEET NUMBER
1 DELTA MARKER
10' - 0"
HEIGHT OF ELEMENT
C1 10' - 0"
CEILING TYPE
CEILING HEIGHT
1 2
A
B
A1 STARTS AT UPPER LEFT CORNER;
NUMBERS ARE VERTICAL GRIDS AND LETTERS
ARE HORIZONTAL GRIDS (EXCLUDES LETTERS "I"
AND "O")
Room name
F B W
F
CPT-01
ROOM NAME
ROOM NUMBER
WALL FINISH
BASE FINISH
FLOOR FINISH
WALL,BASE, OR FLOOR
MATERIAL FINISH CODE
ARROWS REPRESENT EXTENT OF SCOPE
REFER TO FINISH LEGEND
WC-01
00.00
ROOM NAME
150 SF
KEYNOTE TAG
CURTAIN WALL TAG
DOOR TAG
FLOOR TAG
ROOF TAG
WALL TAG
REVISION CLOUD
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
NOT F
OR C
ONSTR
UCTIO
N
G001
INDEX,
GENERAL
NOTES,
LOCATION
MAP,
LEGENDS
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
ABBREVIATION SCHEDULE
Abbrev. Description
# NUMBER OR POUND
& AND
2:1 SL 2 HORIZONTAL TO 1 VERTICAL SLOPE
@ AT
[ CHANNEL
± PLUS MINUS
≤ LESS THAN OR EQUAL TO
≥ GREATER THAN OR EQUAL TO
A
AB ANCHOR BOLT
AC APSHALTIC CONCRETE
ACST ACOUSTIC
AD AREA DRAIN
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ARCH ARCHITECTURAL, ARCHITECT, ARCHITECTURE
ASPH ASPHALT
B
B BASELINE
B BOTTOM
BEJ BRICK EXPANSION JOINT
BLDG BUILDING
BLK BLOCK
BM BEAM
BO BOARD
BRG BEARING
BSMT BASEMENT
C
C&G CURB & GUTTER
CAP CAPACITY
CEM CEMENT
CG CORNER GUARD
CIP CAST IN PLACE, CAST IRON PIPE
CIR CIRCULATING
CJ CONTROL JOINT
CL CENTERLINE
CL CENTERLINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNITS
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CSK COUNTERSUNK
CT CERAMIC TILE
CTR CENTER
D
D DEPTH
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DWG DRAWING
E
E EAST
E/P EDGE OF PAVEMENT
EA EACH
EL ELEVATION
ELECT ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXP JT EXPANSION JOINT
EXT EXTERIOR
F
F.V. FIELD VERIFY
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FFE FINISHED FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FR FRAME
FTG FOOTING
FXTR FIXTURE
G
G GROUND
GA GA
GALV GALVANIZED
GL GLASS
GR GRADE
GRD GROUND
GWB GYPSUM WALL BOARD
H
HB HOSE BIBB
HC HANDICAPPED
HDW HARDWARE
HGT HEIGHT
HORZ HORIZONTAL
HR HOUR
HW HOT WATER
GENERAL NOTES - MISCELLANEOUS
1 THE PROJECT MANUAL, UNDER SEPARATE COVER, IS AN INTEGRAL PART OF THESE CONSTRUCTION DRAWINGS.
2 PLANS, SECTIONS, ELEVATIONS, DETAILS AND DIMENSIONS LABELED "TYPICAL" SHALL APPLY TO ALL SITUATIONS OCCURRING THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY KEYED ON THE DRAWINGS.
3 ALL WORK, MATERIALS, AND METHODS SHALL BE IN CONFORMANCE WITH THE CODES, ORDINANCES AND REGULATIONS
OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION.
4 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION OF SAME ARE PART OF THE CONTRACT AS DEFINED BY THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESSORIES, COMPONENTS AND ASSEMBLIES
REQUIRED FOR THE WORK DEPICTED OR SPECIFIED.
5 CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION ON THE
DOCUMENTS.
6 KEEP SITE CLEAN AND CLEAR OF DEBRIS AND IN ORDERLY CONDITION THAT DOES NOT DETRACT FROM THE
SURROUNDING SITE AND REPAIR ANY DAMAGE CAUSED BY WORK OF THE CONTRACT.
7 ALL DIMENSIONS ARE TO THE FACE OF METAL OR WOOD STUD FRAMED WALLS AND TO THE FACE OF CONCRETE AND
MASONRY WALLS AS SHOWN, UNLESS NOTED OTHERWISE.
8 INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ADJACENT SURFACE. COLOR
REQUIRES ARCHITECTS APPROVAL.
9 DOOR OPENINGS IN FRAME CONSTRUCTION WHICH ARE NOT DIMENSIONED ARE EITHER CENTERED IN THE WALL, FACE
OF JAMB OR LOCATED 4" FROM THE FACE OF STUD TO THE FINISHED JAMB.
10 ALL SPECIAL ACCESSIBLE FACILITIES SHALL BE IDENTIFIED WITH APPROVED SIGNAGE.
11 THE CONTRACTOR IS RESPONSIBLE FOR PRODUCING A WEATHER TIGHT BUILDING, DETAILS AND OMISSIONS TO DRAWINGS NOTWITHSTANDING. ALL DRAWING CONFLICTS WHICH MAY NOT ALLOW A WEATHERTIGHT CONDITION SHALL
BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
12 DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
CONTRACTOR SHALL SUBMIT SPECIFIC DISCREPANCIES FOR ARCHITECT REVIEW.
13 PROVIDE FULL METAL BACKING PLATE (16 GAUGE X 6" HIGH SECURED TO 3 STUDS MIN.) OR WOOD BLOCKING AS REQUIRED TO SECURELY ANCHOR ALL WALL MOUNTED EQUIPMENT (CABINETS, TOILET ROOM ACCESSORIES, HARDWARE, ETC.). BLOCKING SHALL PROVIDE A RIGID CONNECTION CAPABLE OF SUPPORTING DESIGN LOADS. PROVIDE A 16 GAUGE X 6" STL. STUD/TRACK SECURED TO 2 STUDS TO SECURELY SUPPORT ALL WALL STOPS (DOOR BUMPER).
14 COORDINATE WITH ALL TRADES, SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS OR BASES, AS WELL AS ELECTRIC POWER, WATER, AND DRAIN INSTALLATIONS, BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ANY CONCERNS, SPACE LIMITATIONS, OR STRUCTURAL CONFLICTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. A REASONABLE RESPONSE TIME SHALL BE ALLOWED AS NOTED IN
THE SPECIFICATIONS.
15 ALL FLOOR OR WALL OPENINGS REQUIRED FOR PIPES, DUCTS, CONDUITS,ETC. SHALL BE SEALED IN AN APPROVED
MANNER.
16 FIRE SPRINKLER DESIGN TO BE DONE BY A CERTIFIED SUB-CONTRACTOR AND WILL REQUIRE APPROVALS BY THE CITY, AND STATE FIRE MARSHALS. APPROVALS BY THE FIRE MARSHAL ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ARCHITECT. SUBMITTAL TO THE ARCHITECT ALSO INDICATES THAT THE CONTRACTOR HAS REVIEWED AND
COORDINATED FIRE-SPRINKLER PIPING LOCATIONS WITH ALL TRADES.
17 ROOMS ENCLOSED WITH RATED WALLS REQUIRE RATED DOORS. ANY DUCTS PASSING THROUGH WALLS REQUIRE FIRE DAMPERS AND OR FIRE/SMOKE DAMPERS. ANY CONDUIT OR PIPING REQUIRES RATED SEALANT AT JOINTS.
18 GENERAL STRUCTURAL NOTES GOVERN TYPICAL CONDITIONS WHETHER OR NOT SPECIFICALLY DETAILED OR NOTED.
19 IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CASEWORK, DOORS, ETC.
20 THE DRAWINGS AND SPECIFICATIONS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL AND STRUCTURAL DESIGN CONCEPT. THE DIMENSIONS OF THE BUILDING, THE TYPE OF STRUCTURAL, MECHANICAL, ELECTRICAL, AND UTILITY SYSTEMS AND MAJOR ARCHITECTURAL ELEMENTS OF CONSTRUCTION AS
"SCOPE" DOCUMENTS.
21 THE DRAWINGS AND SPECIFICATIONS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE WORK. CONTRACTS SHALL BE LET ON THE BASIS OF SUCH DOCUMENTS, WITH THE UNDERSTANDING THAT THE CONTRACTOR IS TO FURNISH ALL ITEMS REQUIRED FOR PROPER COMPLETION OF THE WORK WITHOUT ADJUSTMENT TO CONTRACT PRICE. IT IS INTENDED THAT THE WORK TO BE OF SOUND AND QUALITY CONSTRUCTION AND THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE INCLUSION OF ADEQUATE AMOUNTS
TO COVER INSTALLATION OF ALL ITEMS INDICATED, DESCRIBED, OR REASONABLY IMPLIED.
DRAWING INDEX
A101 OVERALL PLAN LEVEL 1 - MAIN BUILDING
A201 EXTERIOR ELEVATIONS
A550 EXTERIOR GLAZING DETAILS
A605 EXTERIOR GLAZING SCHEDULE
D101 OVERALL DEMO PLAN LEVEL 1 - MAIN BUILDING
GENERAL
G000 COVER SHEET
G001 INDEX, GENERAL NOTES, LOCATION MAP, LEGENDS
G021 COMCHECKS
ABBREVIATION SCHEDULE
Abbrev. Description
I
ID INSIDE DIAMETER
IE INVERT ELEVATION
INSUL INSULATION
INT INTERIOR
INTX INTERSECTION
INV INVERT
J
JB JUNCTION BOX
JCT JUNCTION
JST JOIST
JT JOINT
L
L ANGLE
L LENGTH
LC LENGTH OF CURVE
LDC LEAD COVERED
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LT LIGHT
M
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MWP MEMBRANE WATERPROOFING
N
N NORTH
NA NOT APPLICABLE
NE NORTHEAST
NEC NATIONAL ELECTRIC CODE
NEUT NEUTRAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
NW NIORTHWEST
O
OA OUTSIDE AIR
OA OUTSIDE AIR
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
OPP OPPOSITE
OVHD OVERHEAD
P
PI POINT IF INTERSECTION
PL PLATE
PLAS PLASTER
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PRELIM PRELIMINARY
PRESS PRESSURE
PRIM PRIMARY
PRTN PARTITION
PT POINT, POINT OF TANGENT
Q
QT QUARRY TILE
R
R RADIUS
RA RETURN AIR
RB RESILIENT VINYL BASE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RECP RECEPTACLE
REINF REINFORCEMENT
REQD REQUIRED
REV REVISION
RF ROOF
RFLCP REFLECTIVE CEILING PLAN
RM ROOM
RVT RESILIENT VINYL TILE
S
S SOUTH
SCH SCHEDULE
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SHT SHEET
SIM SIMILIAR
SL SLOPE
SPEC SPECIFICATION
SQ SQUARE
STL STEEL
SUSP SUSPENDED
T
T TOP
T&B TOP AND BOTTOM
TEL TELEPHONE
TEMP TEMPORARY
TERM TERMINAL
THK THICK/THICKNESS
THRSLD THRESHOLD
TO TOP OF
TOS TOP OF STEEL, TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITION TILE
VENT VENTILIATING
VERT VERTICAL
VEST VESTIBULE
VWC VINYL WALL COVERING
W
W WIDTH, WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WIDTH
WT WEIGHT
WWF WELDED WIRE FABRIC
X
X TRANSFORMER
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
STUDENT
COMMONSVEST.
OFFICE OFFICE
CONF.
T.R.
OFFICE
STOR.
CLOSET
ADMIN. ASSIST. /
WAITING
SHOP
WELDING
COMPRESSOR
WOMEN'S MEN'S
JAN.
CONF. CLASSROOM VEST.
CLASSROOM STOR.
STOR.
STOR.
CORRIDORVEST.
NAILS
CLASSROOM
OFFICE
NAILS SALON
VOCATIONAL
ROOM
CORRIDOR
CLASSROOM
OFFICE MEDIA
STOR.
HAIR SALON
WEST
VOCATIONAL
ROOM
T.R.
HAIR SALON
EAST
VOCATIONAL
ROOM
ESTHETICIAN
ROOM
ESTHETICIAN
ROOM
ESTHETICIAN
ROOM
ESTHETICIAN
ROOM
ES
TH
ET
IC
IA
N
A R
EA
H
A
LL
EXERCISE ROOM EXERCISE ROOM
CORRIDOR
COSMETOLOGY
VOCATIONAL
ROOM
BREAK ROOM
OFFICE OFFICE
D
IS
PE
N
SA
R
Y
RECEP.
RETAILWAITING
VEST. VEST.
OFFICEOFFICE
CLASSROOM CLASSROOM
CLASSROOM
OFFICE OFFICE
HALL
OFFICE OFFICE OFFICE OFFICE
STOR.
STAFF
RESOURCE
WAITING
ELEC. OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
MEN'S
LOCKER /
SHOWER
LOCKER /
SHOWER
WOMEN'S
JAN.
STOR.
OFFICE
MAINTENANCE
SHOP
MAINENANCE
LAB
COMPRESSOR
ROOM
STOR. CLASSROOM
OFFICE OFFICE
MEDIA CENTER
CLASSROOM
T.R. T.R.
WELDING
STOR.
TESTING ROOM
OFFICE
IT
TESTING
OFFICE
OFFICE
OFFICE
OFFICE TEST
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
BOARD ROOM
OFFICE OFFICE
WOMEN'S MEN'S
RECEPTION AREA
OFFICE
RECEPTION AREA
JAN.
OPEN OFFICEOFFICE
CONF.
OFFICE
KITCHEN OFFICE
STOR. STOR.
CORRIDOR
CORRIDOR
CORRIDOR
MEN'S
ELEC.
WOMEN'S
JAN.
STOR.
DINNING DINNING ROOM
COOKLINE
COOKLINE
OFFICE
COOKLINE
COOLER
STOR.JAN.DRY STOR.
COOKLINE
HEATING PLANT
OFFICE
C O
N
FE
R
EN
C E
R O
O M
OFFICE
OPEN OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE OFFICE
OFFICE
OFFICE
OPEN OFFICE OFFICE
WORK
ROOM
OPEN OFFICE
SERVER
ROOM
COMPUTER
ROOM
COMPUTER
LIBRARY
OFFCE
VEST.
STOR.
UNIT SHOP
AUTOMOTIVE
SHOP
STOR.
MEDIA ROOM
MANUALS
OFFICE
OFFICE
CLASSROOM
WOMEN'S
LOCKERS
JAN.
ELEV.
EQUIP.
CORRIDOR STOR. STOR. AIR COMP.ENGINE DYNO. IN-FLOOR DYNO.
DIESEL SHOP
UNIT SHOP
STOR. STOR. OFFICE
OFFICE
MANUALS
SHOWER
MEDIA ROOM
CLASSROOM
LOCKERS
MEN'S
COMMONS
BOOKSTORE
WORK ROOM
SHIP / RECEIVING
ELEC. CHILLER MECH.
RM
MECH.
HALLCONF.OFFICE
BED LAB
CLASSROOM
CONFERENCE
OFFICE
OFFICE OFFICE
OFFICE
CLASSROOM
BED LAB
OFFICE
RESOURCE
CENTER
VEST.CONCOURSECONCOURSE
CONFERENCE
STOR. / JAN.
MEN'S
W O
M
EN
'S OFFICE
PHYSICAL
THERAPY
HEALTH
OCCUPATION
LAB RADIOLOGY
CERTIFIED
NURSING
ASSISTANT DENTAL LAB MEDICAL LAB
DENTAL E-RAY STOR. OFFICE
ELEC.
X-RAYT.R.OFFICE
DATA ROOM
OFFICE
OFFICERADIOLOGYOFFICEOFFICESTOR.
OFFICE OFFICE
BOOKSTORE
ENTRY
CORRIDOR
CLASSROOM CLASSROOM
SHOP
CLASSROOM
CLASSROOM
OFFICE
STOR.ELEC. / STOR.
WOMEN'S
JAN.
MEN'S
STOR.CLASSROOM
OFFICE
STOR.
STOR.STOR.
SHOP
OFFICE
CONF.
UNISEX
CONF.
OFFICE OFFICE
CLASSROOM
STORAGE
1016 1018 P
1018 Q
1018 R
OFFICE
FD
DN
UP
UP
UP
DN
UP
02.08
02.08
02.08
02.08
02.08
02.08
02.08
02.08
02.08
02.08
DEMOLITION PLAN LEGEND
EXISTING CONSTRUCTION
TO BE DEMOLISHED
EXISTING FLOOR FINISH
TO BE REMOVED. PREPARE
EXISTING SLAB FOR NEW FINISH
EXISTING CONCRETE SLAB
TO BE REMOVED
EXISTING CEILING, LAY-IN AND
GRID TO BE REMOVED.
EXISTING CEILING, GYP TO BE
REMOVED.
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
E
D
C
B
A
E
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
DFCM APPROVAL STAMP
D101
OVERALL
DEMO PLAN
LEVEL 1 -
MAIN
BUILDING
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
1/32" = 1'-0"1 LEVEL 1 FLOOR DEMO PLAN
MAIN BUILDING
KEY PLAN
(BARLOW BUILDING)
KEYED NOTES
02.08 REMOVE EXISTING FRAME & GLAZING
GENERAL NOTES - DEMO
1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND
AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS
2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW
CONSTRUCTION
3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION
4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION
5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION
6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC...
7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR
ADJACENT AREAS
8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303)
9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION
DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION
10 GENERAL CONTRACTOR TO CONSULT A WALK THROUGH W/ OWNER & ARCHITECT PRIOR TO COMMENCING DEMOLITION TO IDENTIFY ITEMS NOT LISTED AS 'REMOVE & PRESERVE FOR RE-USE' THAT SHOULD BE SALVAGED AND/OR RESERVED
FOR OWNER'S REUSE IN OTHER PARTS OF THE BUILDING
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
STUDENT
COMMONSVEST.
OFFICE OFFICE
CONF.
T.R.
OFFICE
STOR.
CLOSET
ADMIN. ASSIST. /
WAITING
SHOP
WELDING
COMPRESSOR
WOMEN'S MEN'S
JAN.
CONF. CLASSROOM VEST.
CLASSROOM STOR.
STOR.
STOR.
CORRIDORVEST.
NAILS
CLASSROOM
OFFICE
NAILS SALON
VOCATIONAL
ROOM
CORRIDOR
CLASSROOM
OFFICE MEDIA
STOR.
HAIR SALON
WEST
VOCATIONAL
ROOM
T.R.
HAIR SALON
EAST
VOCATIONAL
ROOM
ESTHETICIAN
ROOM
ESTHETICIAN
ROOM
ESTHETICIAN
ROOM
ESTHETICIAN
ROOM
ES
TH
ET
IC
IA
N
A R
EA
H
A
LL
EXERCISE ROOM EXERCISE ROOM
CORRIDOR
COSMETOLOGY
VOCATIONAL
ROOM
BREAK ROOM
OFFICE OFFICE
D
IS
PE
N
SA
R
Y
RECEP.
RETAILWAITING
VEST. VEST.
OFFICEOFFICE
CLASSROOM CLASSROOM
CLASSROOM
OFFICE OFFICE
HALL
OFFICE OFFICE OFFICE OFFICE
STOR.
STAFF
RESOURCE
WAITING
ELEC. OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
MEN'S
LOCKER /
SHOWER
LOCKER /
SHOWER
WOMEN'S
JAN.
STOR.
OFFICE
MAINTENANCE
SHOP
MAINENANCE
LAB
COMPRESSOR
ROOM
STOR. CLASSROOM
OFFICE OFFICE
MEDIA CENTER
CLASSROOM
T.R. T.R.
WELDING
STOR.
TESTING ROOM
OFFICE
IT
TESTING
OFFICE
OFFICE
OFFICE
OFFICE TEST
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
BOARD ROOM
OFFICE OFFICE
WOMEN'S MEN'S
RECEPTION AREA
OFFICE
RECEPTION AREA
JAN.
OPEN OFFICEOFFICE
CONF.
OFFICE
KITCHEN OFFICE
STOR. STOR.
CORRIDOR
CORRIDOR
CORRIDOR
MEN'S
ELEC.
WOMEN'S
JAN.
STOR.
DINNING DINNING ROOM
COOKLINE
COOKLINE
OFFICE
COOKLINE
COOLER
STOR.JAN.DRY STOR.
COOKLINE
HEATING PLANT
OFFICE
C O
N
FE
R
EN
C E
R O
O M
OFFICE
OPEN OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE OFFICE
OFFICE
OFFICE
OPEN OFFICE OFFICE
WORK
ROOM
OPEN OFFICE
SERVER
ROOM
COMPUTER
ROOM
COMPUTER
LIBRARY
OFFCE
VEST.
STOR.
UNIT SHOP
AUTOMOTIVE
SHOP
STOR.
MEDIA ROOM
MANUALS
OFFICE
OFFICE
CLASSROOM
WOMEN'S
LOCKERS
JAN.
ELEV.
EQUIP.
CORRIDOR STOR. STOR. AIR COMP.ENGINE DYNO. IN-FLOOR DYNO.
DIESEL SHOP
UNIT SHOP
STOR. STOR. OFFICE
OFFICE
MANUALS
SHOWER
MEDIA ROOM
CLASSROOM
LOCKERS
MEN'S
COMMONS
BOOKSTORE
WORK ROOM
SHIP / RECEIVING
ELEC. CHILLER MECH.
RM
MECH.
HALLCONF.OFFICE
BED LAB
CLASSROOM
CONFERENCE
OFFICE
OFFICE OFFICE
OFFICE
CLASSROOM
BED LAB
OFFICE
RESOURCE
CENTER
VEST.CONCOURSECONCOURSE
CONFERENCE
STOR. / JAN.
MEN'S
W O
M
EN
'S OFFICE
PHYSICAL
THERAPY
HEALTH
OCCUPATION
LAB RADIOLOGY
CERTIFIED
NURSING
ASSISTANT DENTAL LAB MEDICAL LAB
DENTAL E-RAY STOR. OFFICE
ELEC.
X-RAYT.R.OFFICE
DATA ROOM
OFFICE
OFFICERADIOLOGYOFFICEOFFICESTOR.
OFFICE OFFICE
BOOKSTORE
ENTRY
CORRIDOR
CLASSROOM CLASSROOM
SHOP
CLASSROOM
CLASSROOM
OFFICE
STOR.ELEC. / STOR.
WOMEN'S
JAN.
MEN'S
STOR.CLASSROOM
OFFICE
STOR.
STOR.STOR.
SHOP
OFFICE
CONF.
UNISEX
CONF.
OFFICE OFFICE
CLASSROOM
STORAGE
1016 1018 P
1018 Q
1018 R
OFFICE
FD
DN
UP
UP
UP
DN
UP
CW4
A201 D1
A201
D4
A201 A1
A201C1
SF2
SF2
SF1
CW21
CW20
CW19
CW19
CW7
SF8
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
E
D
C
B
A
E
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
DFCM APPROVAL STAMP
A101
OVERALL
PLAN LEVEL
1 - MAIN
BUILDING
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
1/32" = 1'-0"1 LEVEL 1 FLOOR PLAN
MAIN BUILDING
KEY PLAN
(BARLOW BUILDING)
GENERAL NOTES - FLOOR PLAN
1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN
CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK
2 DO NOT SCALE THE DRAWINGS
8 SEE SHEET SERIES A600 FOR WINDOW TYPES
9 SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS
10 SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION
11 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN
ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
LEVEL 01
100' - 0"
LEVEL 02
114' - 6"
SF2 SF2 SF1
08.20 02.28
02.65
08.20
E01
LEVEL 01
100' - 0"
LEVEL 02
114' - 6"
LEVEL 01 - LOW
97' - 8"
CW4
02.66 08.2202.28
02.65
D5
A550
LEVEL 01
100' - 0"
LEVEL 02
114' - 6"
LEVEL 01 - LOW
97' - 8"
2'
- 1
1" 7'
- 5
2'
- 6
"SF8
CW7
02.65
08.18
08.22 02.2808.20
LEVEL 01
100' - 0"
LEVEL 02
114' - 6"
CW21 CW20 CW19 CW19
08.22 02.28
02.65
08.22
08.22 08.22
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
E
D
C
B
A
E
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
DFCM APPROVAL STAMP
A201
EXTERIOR
ELEVATIONS
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
1/4" = 1'-0"D1 ELEVATION SF1, SF2
1/4" = 1'-0"D4 ELEVATION CW4
1/4" = 1'-0"A1 ELEVATION CW7, SF8
1/4" = 1'-0"C1 ELEVATION CW19, CW20, CW21
GENERAL NOTES - EXTERIOR ELEVATIONS
1 ALL EXPOSED STRUCTURAL EXTERIOR STEEL SHALL BE GALVANIZED WITHOUT CHROMATE COATING, SHOP PRIMED WITH
HIGH PERFORMANCE COATING
2 SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES
3 SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES
4 SEE SHEET SERIES A500 FOR ARRISCRAFT AND EIFS CORNICE PROFILES
5 SEE SHEET SERIES A500 FOR EXTERIOR RAILING TYPES
6 SEE SHEET A600 WINDOW SURROUND TYPES (WS - #)
KEYED NOTES
02.28 EXISTING WALLS TO REMAIN. PATCH, REPAIR, & TOUCH-UP WALL AS REQ'D
02.65 EXISTING METAL FASCIA AND SOFFIT TO REMAIN; PROTECT, PATCH AND REPAIR AS REQUIRED.
02.66 EXISTING COLUMN IN FRONT OF GLAZING TO REMAIN, REF. PLANS. PROTECT AS REQUIRED.
08.18 REPLACE EXISTING GLAZING AND FRAMING W/ NEW CURTAINWALL SYSTEM; SEE ADD ALTERNATE #1
08.20 STOREFRONT SYSTEM, MATCH EXISTING COLOR; RE: WINDOW SCHEDULE AND DETAILS.
08.22 CURTAINWALL SYSTEM, MATCH EXISTING COLOR; RE. WINDOW SCHEDULE AND DETAILS
ADD ALTERNATE #01
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
EXISTING CONCRETE CURB;
PROTECT AND REPAIR AS
NECESSARY.
THERMALLY BROKEN ALUMINUM
CURTAINWALL MULLION, SEALANT AND
BACKER ROD ENTIRE PERIMETER
BOTH SIDES; SHIM AS NEEDED.
1" INSULATED GLAZING; RE
EXTERIOR GLAZING SCHEDULE.
DRIP EDGE FLASHING
EXISTING INTERIOR PARTITION
W/ BATT INSULATION; PROTECT
AND REPAIR AS NECESSARY
1/2" SOLID SURFACE WINDOW SILL,
MITER CORNER, EASED SQUARE
EDGES; ADHERED TO WALL WITH
HEAVE DUTY ADHESIVE
1 1 /2"
0' - 3 3/4"
0'
- 2
EXISTING BRICK VENEER ASSEMBLY
W/ METAL FRAME BACKING; PROTECT
AND REPAIR AS NECESSARY.
1" INSULATED GLAZING; REF.
EXTERIOR GLAZING SCHEDULE
THERMALLY BROKEN ALUMINUM
CURTAINWALL MULLION, SEALANT AND
BACKER ROD ENTIRE PERIMETER
BOTH SIDES; SHIM AS NEEDED.
EXISTING GYPSUM WALL BOARD,
PAINTED; PROTECT AND REPAIR AS
NECESSARY.
EXISTING INTERIOR WALL;
REF. DIMENSION PLANS
EXISTING METAL INSULATED SOFFIT;
PROTECT AND REPAIR AS NECESSARY.
THERMALLY BROKEN ALUMINUM
CURTAINWALL MULLION, SEALANT AND
BACKER ROD ENTIRE PERIMETER BOTH
SIDES; SHIM AS NEEDED.
FOIL-FACED MINERAL WOOL INSULATION
BEHIND SPANDREL GLAZING; FOIL-TAPE
TO MULLION, TYP.
SPANDREL GLAZING; REF. EXTERIOR
GLAZING SHEET
AIR GAP
1" MIN
1 1/2"x1 1/2" BREAK METAL TRIM COVER
TO MATCH METAL PANEL SOFFIT
EXISTING ACT CEILING, REMOVE AND
PROTECT DURING WINDOW REPLACEMENT.
REPLACE GRID EDGE AS NEEDED.
THERMALLY BROKEN ALUMINUM
CURTAINWALL MULLION, SEALANT AND
BACKER ROD ENTIRE PERIMETER BOTH
SIDES; SHIM AS NEEDED.
1" INSULATED GLAZING ; RE. EXTERIOR
GLAZING SCHEDULE.
FOIL-FACED MINERAL WOOL INSULATION
BEHIND SPANDREL GLAZING; FOIL-TAPE
TO MULLION, TYP.
SPANDREL GLAZING; REF. EXTERIOR
GLAZING SHEET
AIR GAP
1" MIN.
MANUAL ROLLER TUBE AND SHADE
ASSEMBLY, INSTALL PER MANUF
THERMALLY BROKEN ALUMINUM
CURTAINWALL MULLION, SEALANT
AND BACKER ROD ENTIRE PERIMETER
BOTH SIDES; SHIM AS NEEDED.
1" INSULATED GLAZING; RE.
EXTERIOR GLAZING SCHEDULE.
EXISTING BRICK VENEER ASSEMBLY W/
METAL FRAME BACKING; PROTECT AND
REPAIR AS NECESSARY.
THERMALLY BROKEN ALUMINUM
CURTAINWALL MULLION, SEALANT AND
BACKER ROD ENTIRE PERIMETER BOTH
SIDES; SHIM AS NEEDED.
1" INSULATED GLAZING; REF. EXTERIOR
GLAZING SCHEDULE.
WEATHER BARRIER, FIELD VERIFY;
PROTECT AND REPAIR AS NECESSARY.
EXISTING GYPSUM WALL BOARD ASSEMBLY;
PROTECT AND REPAIR AS NECESSARY
1/2" SOLID SURFACE WINDOW SILL, MITER
CORNER, EASED SQUARE EDGES; ADHERED
TO WALL WITH HEAVE DUTY ADHESIVE
EXISTING INSULATED METAL PANEL;
PROTECT AND REPAIR AS NECESSARY.
EXISTING METAL FRAMING W/ INSULATION;
PROTECT AND REPAIR AS NECESSARY
THERMALLY BROKEN ALUMINUM CURTAINWALL
MULLION, SEALANT AND BACKER ROD ENTIRE
PERIMETER BOTH SIDES; SHIM AS NEEDED.
TWO-PIECE HEAD FLASHING W/
CONTINUOUS BUTYL FLASHING BETWEEN
PIECES. TO MATCH GLAZING FINISH
EXTERIOR CAP TRIM W/ HEMMED EDGE FASTENED W/
POP RIVETS @ 8" O.C. TO MATCH EXISTING FINISH
FASTEN FLASHING W/ LOW PROFILE THROUGH
FASTENER W/ CONTINUOUS BUTYL SEAL
CONTINUOUS BUTYL SEALANT; MARRIAGE BED
TO VERTICAL PANEL JOINT AS ALLOWABLE
FOIL-FACED MINERAL WOOL INSULATION BEHIND
SPANDREL GLAZING; FOIL-TAPE TO MULLION, TYP.
SPANDREL GLAZING; REF. EXTERIOR
GLAZING SHEET
1" MIN.
EXISTING CONCRETE FOUNDATION;
PROTECT AND REPAIR AS NEEDED.
SILL FLASHING
THERMALLY BROKEN ALUMINUM
STOREFRONT SILL, SEALANT AND
BACKER ROD ENTIRE PERIMETER BOTH
SIDES; SHIM AS NEEDED.
FOIL-FACED MINERAL WOOL INSULATION
BEHIND SPANDREL GLAZING; FOIL-TAPE
TO MULLION, TYP.
METAL STUD WALL ASSEMBLY TO
REMAIN, PATCH AND REPAIR AS NEEDED
GYPSUM WALL BOARD TO REMAIN, ,
PATCH AND REPAIR AS NEEDED
1" SPANDREL GLAZING; RE. EXTERIOR
GLAZING SCHEDULE
0'
- 2
0' - 1"
1" MIN.
GLAZING; RE: EXTERIOR
GLAZING SCHEDULE
EXISTING STUD FRAMING
AND INSULATION TO REMAIN
SPANDREL GLAZING W/ FOIL FACE
MINERAL WOOL INSULATION
EXISTING WALL BASE TO REMAIN
EXISTING GYP. BOARD, PAINT TO
BE TOUCHED UP AS NEEDED
FOIL-FACED MINERAL WOOL INSULATION
BEHIND SPANDREL GLAZING; FOIL-TAPE
TO MULLION, TYP.
1/2" SOLID SURFACE WINDOW SILL, MITER
CORNER, EASED SQUARE EDGES; ADHERED TO
WALL WITH HEAVE DUTY ADHESIVE
JOINT SEALANT
EXISTING COLUMN WRAP TO REMAIN,
PROTECT AND REPAIR AS NECESSARY
EXISTING BREAK METAL WALL END CAP TO
REMAIN, PROTECT AND REPAIR AS NECESSARY
1/2" SOLID SURFACE WINDOW SILL, MITER
CORNER, EASED SQUARE EDGES; ADHERED TO
WALL WITH HEAVE DUTY ADHESIVE
EXISTING INTERIOR WALL TO REMAIN
PATCH AND REPAIR AS NECESSARY
EXISTING INSULATED METAL PANEL;
PROTECT AND REPAIR AS NECESSARY.
EXISTING METAL FRAMING W/ INSULATION;
PROTECT AND REPAIR AS NECESSARY
THERMALLY BROKEN ALUMINUM STOREFRONT
MULLION, SEALANT AND BACKER ROD ENTIRE
PERIMETER BOTH SIDES; SHIM AS NEEDED.
TWO-PIECE HEAD FLASHING W/
CONTINUOUS BUTYL FLASHING BETWEEN
PIECES. TO MATCH GLAZING FINISH
EXTERIOR CAP TRIM W/ HEMMED EDGE FASTENED W/
POP RIVETS @ 8" O.C. TO MATCH EXISTING FINISH
FASTEN FLASHING W/ LOW PROFILE THROUGH
FASTENER W/ CONTINUOUS BUTYL SEAL
CONTINUOUS BUTYL SEALANT; MARRIAGE BED
TO VERTICAL PANEL JOINT AS ALLOWABLE
SPANDREL GLAZING; REF. EXTERIOR
GLAZING SHEET
EXISTING CONCRETE CURB;
PROTECT AND REPAIR AS
NECESSARY.
THERMALLY BROKEN ALUMINUM
STOREFRONT SILL, SEALANT AND
BACKER ROD ENTIRE PERIMETER
BOTH SIDES; SHIM AS NEEDED.
1" INSULATED GLAZING; RE
EXTERIOR GLAZING SCHEDULE.
DRIP EDGE FLASHING
EXISTING INTERIOR PARTITION
W/ BATT INSULATION; PROTECT
AND REPAIR AS NECESSARY
1/2" SOLID SURFACE WINDOW SILL,
MITER CORNER, EASED SQUARE
EDGES; ADHERED TO WALL WITH
HEAVE DUTY ADHESIVE
1 1 /2"
0'
- 2
0' - 3 3/4"
EXISTING BRICK VENEER ASSEMBLY W/
METAL FRAME BACKING; PROTECT AND
REPAIR AS NECESSARY.
THERMALLY BROKEN ALUMINUM
STOREFRONT MULLION, SEALANT AND
BACKER ROD ENTIRE PERIMETER BOTH
SIDES; SHIM AS NEEDED.
1" INSULATED GLAZING; REF. EXTERIOR
GLAZING SCHEDULE.
WEATHER BARRIER, FIELD VERIFY;
PROTECT AND REPAIR AS NECESSARY.
EXISTING GYPSUM WALL BOARD ASSEMBLY;
PROTECT AND REPAIR AS NECESSARY
1/2" SOLID SURFACE WINDOW SILL, MITER
CORNER, EASED SQUARE EDGES; ADHERED
TO WALL WITH HEAVE DUTY ADHESIVE
GLAZING; RE: EXTERIOR
GLAZING SCHEDULE
EXISTING STUD FRAMING
AND INSULATION TO REMAIN
SPANDREL GLAZING W/ FOIL FACE
MINERAL WOOL INSULATION
EXISTING WALL BASE TO REMAIN
EXISTING GYP. BOARD, PAINT TO
BE TOUCHED UP AS NEEDED
FOIL-FACED MINERAL WOOL INSULATION
BEHIND SPANDREL GLAZING; FOIL-TAPE
TO MULLION, TYP.
1/2" SOLID SURFACE WINDOW SILL, MITER
CORNER, EASED SQUARE EDGES; ADHERED TO
WALL WITH HEAVE DUTY ADHESIVE
JOINT SEALANT
3" = 1'-0"B2 DETAIL - CW HEAD @ INSULATED METAL PANEL
3" = 1'-0"B5 DETAIL - CW JAMB @ BRICK
3" = 1'-0"A2 DETAIL - CW HEAD @ METAL PANEL SOFFIT
3" = 1'-0"A5 DETAIL - CW JAMB @ BRICK RETURN
3" = 1'-0"B6 DETAIL - CW SILL @ GRADE
3" = 1'-0"C6 DETAIL - SF SILL @ FOUNDATION GRADE
3" = 1'-0"A6 DETAIL - CW SILL @ RAISED FOUNDATION
3" = 1'-0"A3 DETAIL - CW CEILING TERMINATION @ MULLION
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
E
D
C
B
A
E
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
DFCM APPROVAL STAMP
A550
EXTERIOR
GLAZING
DETAILS
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
1 1/2" = 1'-0"B3 DETAIL - CW SILL @ FURRED SPANDREL
3" = 1'-0"D5 PLAN DETAIL @ COLUMN
3" = 1'-0"C2 DETAIL - SF HEAD @ INSULATED METAL PANEL
3" = 1'-0"D6 DETAIL - SF SILL @ RAISED FOUNDATION
3" = 1'-0"C5 DETAIL - SF JAMB @ BRICK
1 1/2" = 1'-0"C3 DETAIL - SF SILL @ FURRED SPANDREL
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
STOREFRONT SYSTEM
AREA: 105 SF.
B6
A550
1' - 10 3/4" 3' - 0" 5' - 1 1/4"
1'
- 6
6'
- 2
2'
- 1
0"
10' - 0"
6"
P1 P1
G2
G2
G2
A3
A550
SIM
C5
A550
C2
A550
G1
E01
G2
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
STOREFRONT SYSTEM
AREA: 105 SF.
C6
A550
G1
P1P1
G1
P1 P1
6"
1'
- 6
6'
- 2
2'
- 1
0"
5' - 0" 5' - 0"
10' - 0"
A3
A550
SIM
C2
A550
B5
A550 C3
A550
A2
A550
A5
A550
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
CURTAIN WALL SYSTEM
AREA: 210 SF.
A6
A550
A3
A550
EXISTING COLUMN IN FRONT OF GLAZING
TO REMAIN, PROTECT AS REQUIRED
P1
G1
P1
G1
P1
G1
P1
G1
6" 2'
- 4
2'
- 1
0" 7'
- 8
20' - 0"
5' - 0"5' - 0"5' - 0"5' - 0"
D5
A550
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
CURTAIN WALL SYSTEM
AREA: 105 SF.
G1
P1 P1
G1
P1P1
1'
- 6
6'
- 2
2'
- 1
0"
6"
5' - 0" 5' - 0"
10' - 0"
A3
A550
B5
A550
B2
A550
C6
A550
B3
A550
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
CURTAIN WALL SYSTEM
AREA: 210 SF.
G1
P1 P1
G1
P1
G1
P1
G1
P1P1P1P1
5' - 0" 5' - 0" 5' - 0" 5' - 0"
20' - 0"
1'
- 6
6'
- 2
2'
- 1
0"
6"
A3
A550 B5
A550
B2
A550
C6
A550
B3
A550
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
CURTAIN WALL SYSTEM
AREA: 81 SF.
G1 G1
P1 P1
P1 P1
1'
- 6
6'
- 2
2'
- 1
0"
6"
7' - 8"
3' - 10" 3' - 10"
B5
A550
B2
A550
C6
A550
A3
A550
B3
A550
SPANDREL GLASS PANEL.
DARK BRONZE.
CURTAIN WALL SYSTEM
AREA: 736 SF.
G1
P1P1
G1
P1 P1
G1
P1
P1P1
P1
G1G1
P1
P1P1
G1
P1
P1
G1
P1
P1
G1
P1
P1
G1
P1
P1
G1
P1
2'
- 1
0" 7'
- 6
2'
- 6
58' - 1"
4' - 1"
TYP.
5' - 0" 4' - 0"
A3
A550
A5
A550
A5
A550
OPP
G1
P1P1
G1
P1P1
A2
A550
B6
A550
B3
A550
SPANDREL GLASS PANEL.
DARK BRONZE ALUM.
STOREFRONT SYSTEM
AREA: 53 SF.
G1
P1
2'
- 1
0" 7'
- 8 "10
6"
5' - 0"
A3
A550
SIM
C2
A550
D6
A550
1/4" = 1'-0"D1 SF 1
1/4" = 1'-0"D2 SF 2 (2X)
1/4" = 1'-0"D3 CW 4
1/4" = 1'-0"C2 CW 7
1/4" = 1'-0"C5 SF 8
1/4" = 1'-0"D4 CW 19 (2X)
1/4" = 1'-0"D5 CW 20
1/4" = 1'-0"D6 CW 21
3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:
title:
revisions :
p r o j e c t # :
d a t e :
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND
DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS
NOT INTENDED FOR CONSTRUCTION, RECORDING
PURPOSES, OR IMPLEMENTATION
THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING
ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &
MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE
COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN
WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS
WRITTEN PERMISSION FROM METHOD STUDIO INC.
project:
E
D
C
B
A
E
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
DFCM APPROVAL STAMP
A605
EXTERIOR
GLAZING
SCHEDULE
26.0185
07/16/2026
550 E 300 S, KAYSVILLE, UT 84037
Davis Tech Main Building Glazing
GLAZING SCHEDULE
G1 1" DOUBLE PANE INSULATED GLAZING - LOW E
G2 1" DOUBLE PANE INSULATED TEMPERED GLAZING
P1 1" DOUBLE PANE INSULATED GLAZING - HEAT TREATED
GLAZING GENERAL NOTES
1 CONTRACTOR TO CONFIRM AND VERIFY QUANTITIES OF ALL GLAZING TYPES
2 ALL GLAZING DIMENSIONS TO BE FIELD VERIFIED PRIOR TO BIDDING, ORDERING, AND INSTALLING
3 ROUGH OPENING REQUIREMENTS SHALL BE COORDINATED WITH WINDOW MANUFACTURER, TYP
4 ALL CURTAINWALL SYSTEMS REQUIRE DELEGATED DESIGN SUBMITTAL
5 SEE DOOR SCHEDULE FOR SCHEDULED GLAZING WITHIN DOORS
6 SEE FLOOR PLAN AND ELEVATIONS FOR WALL TYPE AND MATERIAL CONDITION IN REFERING TO WINDOW AND
STOREFRONT DETAILS
7 SAFETY GLAZING SHALL BE INSTALLED IN HAZARDOUS LOCATIONS WITH IBC 2406.4, THIS INCLUDES GLAZING IN WINDOW, STOREFRONT, AND DOOR TYPES.
FRAME FINISH SCHEDULE
CW4 DARK BRONZE
CW7 DARK BRONZE
CW19 DARK BRONZE
CW20 DARK BRONZE
CW21 DARK BRONZE
SF1 DARK BRONZE
SF2 DARK BRONZE
ADD ALTERNATE #01
ALL DOOR HANDLES & HARDWARE USED ON THE PROJECT MUST NOT REQUIRE PINCHING, TIGHT GRASPING, OR TWISTING OF THE WRIST IN ORDER TO OPERATE, IN ACCORDANCE WITH 2018 IBC 1010.1.9.1
DOOR SCHEDULE - ALL
DOOR
NUMBER
ROOMS DOOR DIMENSIONS DOOR FRAME FIRE
RATING
PANIC
HW
CARD
ACCESS ELEC HW CLOSER LOCKING
OCC
INDICATOR
SMOKE
SEAL HW SET
DOOR
NUMBER COMMENTSTO RM # WIDTH HEIGHT THK TYPE MATERIAL FINISH TYPE MATERIAL FINISH
LEVEL 01
E01 3' - 0" 7' - 0 3/4" 2" DT1 SF SINGLE GLASS MATCH EXISTING FT1 ALUMINUM MATCH EXISTING ● ● 01 E01
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
| G000 - COVER SHEET |
| G001 - INDEX, GENERAL NOTES, LOCATION MAP, LEGENDS |
| D101 - OVERALL DEMO PLAN LEVEL 1 - MAIN BUILDING |
| A101 - OVERALL PLAN LEVEL 1 - MAIN BUILDING |
| A201 - EXTERIOR ELEVATIONS |
| A550 - EXTERIOR GLAZING DETAILS |
| A605 - EXTERIOR GLAZING SCHEDULE |