6-2-CS27020-27049220-Approved Plans.pdf

PDF 3 MB Posted

Attached to
DFCM Construction - Prequalified General Stage II - Davis Technical College - Main Building Glazing Replacement - Phase I - Project #27049220
Solicitation number
CS27020
Issued by
Utah

About this file

This file contains approved construction plans for the Davis Technical College Main Building Glazing Replacement project, prepared by the Utah Division of Facilities Construction and Management (DFCM) and Method Studio Inc. The project involves replacing exterior glazing and window systems in select portions of the Main Building, specifically the Hair and Nail Salon Vocational Rooms (CW 7 and SF 8). The base bid improvements include work on the Barlow Building, Allied Health Building, Simmons Building, and Main Building, with Add Alternate 01 addressing exterior glazing removal and replacement with new exterior storefront and curtain wall systems. The project includes delegated design requiring comprehensive engineering analysis and performance requirements by a qualified professional engineer. The construction cost estimate is $265,000.00, and only contractors prequalified under Stage I and currently listed on the DFCM Prequalified Contractors list are eligible to bid on this Stage II invitation to bid.

The approved plans include detailed architectural drawings, exterior elevation sheets, glazing schedules, and construction details dated July 16, 2026, with code compliance review completed by Thomas Peterson on August 25, 2026. Glazing specifications include double-pane insulated glazing with low-E coating (G1), double-pane insulated tempered glazing (G2), and heat-treated insulated glazing (P1). All curtainwall systems require delegated design submittals, and safety glazing must be installed in hazardous locations per IBC 2406.4. The project owner is Davis Technical College located at 550 E 300 S, Kaysville, UT 84037, with contact Bryce Fox serving as the owner's representative and Kelton Berrett as the architect at Method Studio. All work must comply with applicable codes, ordinances, and regulations, and the contractor is responsible for producing a weathertight building and coordinating with mechanical, plumbing, and electrical trades.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADD ALTERNATES

1. EXTERIOR GLAZING

Remove and replace existing exterior glazing systems with new exterior storefront and curtain wall systems in the following locations:

- Main Building - CW 7 & SF 8 (Hair and Nail Salon Vocational Rooms)

NOTE:

DELEGATED DESIGN: DESIGN ALUMINUM-FRAMED SYSTEMS AND

ATTACHMENT TO STRUCTURE, INCLUDING COMPREHENSIVE

ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER,

USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED.

BASE BID IMPROVEMENTS

BARLOW BUILDING

ALLIED HEALTH BUILDING

SIMMONS BUILDING

MAIN BUILDING

ADD ALTERNATE 01

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

DFCM APPROVAL STAMP

G000

COVER

SHEET

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

Davis Tech Main Building Glazing 07/16/2026 owner davis technical college 550 E 300 S kaysville, ut 84037

(801) 593-2500 contact: bryce fox architect method studio 360 w aspen ave salt lake city, ut 84101

(801) 532-4422 contact: kelton berrett

DFCM Project No. 27049220

VICINITY MAP

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

THOMAS PETERSON

08/25/2026

MATERIAL LEGEND

EARTH (EXISTING)

EARTH (BACKFILL)

DRAINAGE FILL

COMPACTED FILL

CONCRETE

CAST-IN-PLACE

CONCRETE

PRECAST

BRICK

CONCRETE MASONRY

UNIT

GROUT

STEEL

ALUMINUM

CONTINUOUS WOOD

SHEATHING

INTERMITTENT WOOD

BLOCKING

WOOD FINISH

HARDBOARD

PARTICLE BOARD

BATT INSULATION

LOOSE FILL INSULATION

RIGID INSULATION

FIRE SPRAY

GYPSUM BOARD

ARCHITECTURE SYMBOLS

A102

SHEET TYPE

DISCIPLINE

SHEET NUMBER SEQUENCE

XX

000x

F1

R1

WALL FUNCTION

CORE MATERIAL

CORE SIZE (ROUNDED)

MODIFIER

101M

AWS STANDARD CASEWORK TYPE

MODIFIED CASEWORK TYPE

REFER TO CASEWORK DESIGN SERIES (CDS) OF

THE ARCHITECTURAL WOODWORK STANDARDS

(AWS) FOR A FULL DESCRIPTION OF CASEWORK

TYPES

100' - 0"

MAIN LEVEL

LEVEL NAME

LEVEL ELEVATION

AE000

1 Ref

Re f

1 Ref

Re f

AE000

1 Ref

Re f

1 Ref

Re f

SHEET NUMBER

POSITION ON SHEET

SHEET NUMBER

POSITION ON SHEET

DRAWING NUMBER

VIEW NAME

DRAWING SCALE

ORIGINAL SOURCE OF DETAIL

A101

A101

POSITION ON SHEET

SHEET NUMBER

SHEET NUMBER

VIEW DIRECTION

POSITION ON SHEET

A1

AE101

SIM

A1

AE101

SIM

A1

AE101

SIM

VIEW DIRECTION

POSITION ON SHEET

SHEET NUMBER

ROOM NUMBER

ROOM AREA

01A

SIGN TYPE

SIGN NUMBER

VIEW DIRECTION

POSITION ON SHEET

SHEET NUMBER

1 DELTA MARKER

10' - 0"

HEIGHT OF ELEMENT

C1 10' - 0"

CEILING TYPE

CEILING HEIGHT

1 2

A

B

A1 STARTS AT UPPER LEFT CORNER;

NUMBERS ARE VERTICAL GRIDS AND LETTERS

ARE HORIZONTAL GRIDS (EXCLUDES LETTERS "I"

AND "O")

Room name

F B W

F

CPT-01

ROOM NAME

ROOM NUMBER

WALL FINISH

BASE FINISH

FLOOR FINISH

WALL,BASE, OR FLOOR

MATERIAL FINISH CODE

ARROWS REPRESENT EXTENT OF SCOPE

REFER TO FINISH LEGEND

WC-01

00.00

ROOM NAME

150 SF

KEYNOTE TAG

CURTAIN WALL TAG

DOOR TAG

FLOOR TAG

ROOF TAG

WALL TAG

REVISION CLOUD

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

NOT F

OR C

ONSTR

UCTIO

N

G001

INDEX,

GENERAL

NOTES,

LOCATION

MAP,

LEGENDS

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

ABBREVIATION SCHEDULE

Abbrev. Description

# NUMBER OR POUND

& AND

2:1 SL 2 HORIZONTAL TO 1 VERTICAL SLOPE

@ AT

[ CHANNEL

± PLUS MINUS

≤ LESS THAN OR EQUAL TO

≥ GREATER THAN OR EQUAL TO

A

AB ANCHOR BOLT

AC APSHALTIC CONCRETE

ACST ACOUSTIC

AD AREA DRAIN

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

ALT ALTERNATE

ALUM ALUMINUM

ARCH ARCHITECTURAL, ARCHITECT, ARCHITECTURE

ASPH ASPHALT

B

B BASELINE

B BOTTOM

BEJ BRICK EXPANSION JOINT

BLDG BUILDING

BLK BLOCK

BM BEAM

BO BOARD

BRG BEARING

BSMT BASEMENT

C

C&G CURB & GUTTER

CAP CAPACITY

CEM CEMENT

CG CORNER GUARD

CIP CAST IN PLACE, CAST IRON PIPE

CIR CIRCULATING

CJ CONTROL JOINT

CL CENTERLINE

CL CENTERLINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNITS

COL COLUMN

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS

CPT CARPET

CSK COUNTERSUNK

CT CERAMIC TILE

CTR CENTER

D

D DEPTH

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DN DOWN

DS DOWNSPOUT

DWG DRAWING

E

E EAST

E/P EDGE OF PAVEMENT

EA EACH

EL ELEVATION

ELECT ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXP EXPANSION

EXP JT EXPANSION JOINT

EXT EXTERIOR

F

F.V. FIELD VERIFY

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FFE FINISHED FLOOR ELEVATION

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIN FINISH

FLR FLOOR

FR FRAME

FTG FOOTING

FXTR FIXTURE

G

G GROUND

GA GA

GALV GALVANIZED

GL GLASS

GR GRADE

GRD GROUND

GWB GYPSUM WALL BOARD

H

HB HOSE BIBB

HC HANDICAPPED

HDW HARDWARE

HGT HEIGHT

HORZ HORIZONTAL

HR HOUR

HW HOT WATER

GENERAL NOTES - MISCELLANEOUS

1 THE PROJECT MANUAL, UNDER SEPARATE COVER, IS AN INTEGRAL PART OF THESE CONSTRUCTION DRAWINGS.

2 PLANS, SECTIONS, ELEVATIONS, DETAILS AND DIMENSIONS LABELED "TYPICAL" SHALL APPLY TO ALL SITUATIONS OCCURRING THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY KEYED ON THE DRAWINGS.

3 ALL WORK, MATERIALS, AND METHODS SHALL BE IN CONFORMANCE WITH THE CODES, ORDINANCES AND REGULATIONS

OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION.

4 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION OF SAME ARE PART OF THE CONTRACT AS DEFINED BY THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESSORIES, COMPONENTS AND ASSEMBLIES

REQUIRED FOR THE WORK DEPICTED OR SPECIFIED.

5 CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION ON THE

DOCUMENTS.

6 KEEP SITE CLEAN AND CLEAR OF DEBRIS AND IN ORDERLY CONDITION THAT DOES NOT DETRACT FROM THE

SURROUNDING SITE AND REPAIR ANY DAMAGE CAUSED BY WORK OF THE CONTRACT.

7 ALL DIMENSIONS ARE TO THE FACE OF METAL OR WOOD STUD FRAMED WALLS AND TO THE FACE OF CONCRETE AND

MASONRY WALLS AS SHOWN, UNLESS NOTED OTHERWISE.

8 INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ADJACENT SURFACE. COLOR

REQUIRES ARCHITECTS APPROVAL.

9 DOOR OPENINGS IN FRAME CONSTRUCTION WHICH ARE NOT DIMENSIONED ARE EITHER CENTERED IN THE WALL, FACE

OF JAMB OR LOCATED 4" FROM THE FACE OF STUD TO THE FINISHED JAMB.

10 ALL SPECIAL ACCESSIBLE FACILITIES SHALL BE IDENTIFIED WITH APPROVED SIGNAGE.

11 THE CONTRACTOR IS RESPONSIBLE FOR PRODUCING A WEATHER TIGHT BUILDING, DETAILS AND OMISSIONS TO DRAWINGS NOTWITHSTANDING. ALL DRAWING CONFLICTS WHICH MAY NOT ALLOW A WEATHERTIGHT CONDITION SHALL

BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.

12 DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.

CONTRACTOR SHALL SUBMIT SPECIFIC DISCREPANCIES FOR ARCHITECT REVIEW.

13 PROVIDE FULL METAL BACKING PLATE (16 GAUGE X 6" HIGH SECURED TO 3 STUDS MIN.) OR WOOD BLOCKING AS REQUIRED TO SECURELY ANCHOR ALL WALL MOUNTED EQUIPMENT (CABINETS, TOILET ROOM ACCESSORIES, HARDWARE, ETC.). BLOCKING SHALL PROVIDE A RIGID CONNECTION CAPABLE OF SUPPORTING DESIGN LOADS. PROVIDE A 16 GAUGE X 6" STL. STUD/TRACK SECURED TO 2 STUDS TO SECURELY SUPPORT ALL WALL STOPS (DOOR BUMPER).

14 COORDINATE WITH ALL TRADES, SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS OR BASES, AS WELL AS ELECTRIC POWER, WATER, AND DRAIN INSTALLATIONS, BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ANY CONCERNS, SPACE LIMITATIONS, OR STRUCTURAL CONFLICTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. A REASONABLE RESPONSE TIME SHALL BE ALLOWED AS NOTED IN

THE SPECIFICATIONS.

15 ALL FLOOR OR WALL OPENINGS REQUIRED FOR PIPES, DUCTS, CONDUITS,ETC. SHALL BE SEALED IN AN APPROVED

MANNER.

16 FIRE SPRINKLER DESIGN TO BE DONE BY A CERTIFIED SUB-CONTRACTOR AND WILL REQUIRE APPROVALS BY THE CITY, AND STATE FIRE MARSHALS. APPROVALS BY THE FIRE MARSHAL ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ARCHITECT. SUBMITTAL TO THE ARCHITECT ALSO INDICATES THAT THE CONTRACTOR HAS REVIEWED AND

COORDINATED FIRE-SPRINKLER PIPING LOCATIONS WITH ALL TRADES.

17 ROOMS ENCLOSED WITH RATED WALLS REQUIRE RATED DOORS. ANY DUCTS PASSING THROUGH WALLS REQUIRE FIRE DAMPERS AND OR FIRE/SMOKE DAMPERS. ANY CONDUIT OR PIPING REQUIRES RATED SEALANT AT JOINTS.

18 GENERAL STRUCTURAL NOTES GOVERN TYPICAL CONDITIONS WHETHER OR NOT SPECIFICALLY DETAILED OR NOTED.

19 IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CASEWORK, DOORS, ETC.

20 THE DRAWINGS AND SPECIFICATIONS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL AND STRUCTURAL DESIGN CONCEPT. THE DIMENSIONS OF THE BUILDING, THE TYPE OF STRUCTURAL, MECHANICAL, ELECTRICAL, AND UTILITY SYSTEMS AND MAJOR ARCHITECTURAL ELEMENTS OF CONSTRUCTION AS

"SCOPE" DOCUMENTS.

21 THE DRAWINGS AND SPECIFICATIONS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE WORK. CONTRACTS SHALL BE LET ON THE BASIS OF SUCH DOCUMENTS, WITH THE UNDERSTANDING THAT THE CONTRACTOR IS TO FURNISH ALL ITEMS REQUIRED FOR PROPER COMPLETION OF THE WORK WITHOUT ADJUSTMENT TO CONTRACT PRICE. IT IS INTENDED THAT THE WORK TO BE OF SOUND AND QUALITY CONSTRUCTION AND THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE INCLUSION OF ADEQUATE AMOUNTS

TO COVER INSTALLATION OF ALL ITEMS INDICATED, DESCRIBED, OR REASONABLY IMPLIED.

DRAWING INDEX

A101 OVERALL PLAN LEVEL 1 - MAIN BUILDING

A201 EXTERIOR ELEVATIONS

A550 EXTERIOR GLAZING DETAILS

A605 EXTERIOR GLAZING SCHEDULE

D101 OVERALL DEMO PLAN LEVEL 1 - MAIN BUILDING

GENERAL

G000 COVER SHEET

G001 INDEX, GENERAL NOTES, LOCATION MAP, LEGENDS

G021 COMCHECKS

ABBREVIATION SCHEDULE

Abbrev. Description

I

ID INSIDE DIAMETER

IE INVERT ELEVATION

INSUL INSULATION

INT INTERIOR

INTX INTERSECTION

INV INVERT

J

JB JUNCTION BOX

JCT JUNCTION

JST JOIST

JT JOINT

L

L ANGLE

L LENGTH

LC LENGTH OF CURVE

LDC LEAD COVERED

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LT LIGHT

M

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MET METAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTG MOUNTING

MULL MULLION

MWP MEMBRANE WATERPROOFING

N

N NORTH

NA NOT APPLICABLE

NE NORTHEAST

NEC NATIONAL ELECTRIC CODE

NEUT NEUTRAL

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

NW NIORTHWEST

O

OA OUTSIDE AIR

OA OUTSIDE AIR

OC ON CENTER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI OWNER FURNISHED, OWNER INSTALLED

OPP OPPOSITE

OVHD OVERHEAD

P

PI POINT IF INTERSECTION

PL PLATE

PLAS PLASTER

PLYWD PLYWOOD

PNL PANEL

PNT PAINT

PRELIM PRELIMINARY

PRESS PRESSURE

PRIM PRIMARY

PRTN PARTITION

PT POINT, POINT OF TANGENT

Q

QT QUARRY TILE

R

R RADIUS

RA RETURN AIR

RB RESILIENT VINYL BASE

RCP REINFORCED CONCRETE PIPE

RD ROOF DRAIN

RECP RECEPTACLE

REINF REINFORCEMENT

REQD REQUIRED

REV REVISION

RF ROOF

RFLCP REFLECTIVE CEILING PLAN

RM ROOM

RVT RESILIENT VINYL TILE

S

S SOUTH

SCH SCHEDULE

SD STORM DRAIN

SE SOUTHEAST

SECT SECTION

SHT SHEET

SIM SIMILIAR

SL SLOPE

SPEC SPECIFICATION

SQ SQUARE

STL STEEL

SUSP SUSPENDED

T

T TOP

T&B TOP AND BOTTOM

TEL TELEPHONE

TEMP TEMPORARY

TERM TERMINAL

THK THICK/THICKNESS

THRSLD THRESHOLD

TO TOP OF

TOS TOP OF STEEL, TOP OF SLAB

TOW TOP OF WALL

TYP TYPICAL

U

UNO UNLESS NOTED OTHERWISE

V

VCT VINYL COMPOSITION TILE

VENT VENTILIATING

VERT VERTICAL

VEST VESTIBULE

VWC VINYL WALL COVERING

W

W WIDTH, WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WIDTH

WT WEIGHT

WWF WELDED WIRE FABRIC

X

X TRANSFORMER

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

STUDENT

COMMONSVEST.

OFFICE OFFICE

CONF.

T.R.

OFFICE

STOR.

CLOSET

ADMIN. ASSIST. /

WAITING

SHOP

WELDING

COMPRESSOR

WOMEN'S MEN'S

JAN.

CONF. CLASSROOM VEST.

CLASSROOM STOR.

STOR.

STOR.

CORRIDORVEST.

NAILS

CLASSROOM

OFFICE

NAILS SALON

VOCATIONAL

ROOM

CORRIDOR

CLASSROOM

OFFICE MEDIA

STOR.

HAIR SALON

WEST

VOCATIONAL

ROOM

T.R.

HAIR SALON

EAST

VOCATIONAL

ROOM

ESTHETICIAN

ROOM

ESTHETICIAN

ROOM

ESTHETICIAN

ROOM

ESTHETICIAN

ROOM

ES

TH

ET

IC

IA

N

A R

EA

H

A

LL

EXERCISE ROOM EXERCISE ROOM

CORRIDOR

COSMETOLOGY

VOCATIONAL

ROOM

BREAK ROOM

OFFICE OFFICE

D

IS

PE

N

SA

R

Y

RECEP.

RETAILWAITING

VEST. VEST.

OFFICEOFFICE

CLASSROOM CLASSROOM

CLASSROOM

OFFICE OFFICE

HALL

OFFICE OFFICE OFFICE OFFICE

STOR.

STAFF

RESOURCE

WAITING

ELEC. OFFICE

OFFICE

OFFICE

OFFICEOFFICE

OFFICE

OFFICE

MEN'S

LOCKER /

SHOWER

LOCKER /

SHOWER

WOMEN'S

JAN.

STOR.

OFFICE

MAINTENANCE

SHOP

MAINENANCE

LAB

COMPRESSOR

ROOM

STOR. CLASSROOM

OFFICE OFFICE

MEDIA CENTER

CLASSROOM

T.R. T.R.

WELDING

STOR.

TESTING ROOM

OFFICE

IT

TESTING

OFFICE

OFFICE

OFFICE

OFFICE TEST

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

BOARD ROOM

OFFICE OFFICE

WOMEN'S MEN'S

RECEPTION AREA

OFFICE

RECEPTION AREA

JAN.

OPEN OFFICEOFFICE

CONF.

OFFICE

KITCHEN OFFICE

STOR. STOR.

CORRIDOR

CORRIDOR

CORRIDOR

MEN'S

ELEC.

WOMEN'S

JAN.

STOR.

DINNING DINNING ROOM

COOKLINE

COOKLINE

OFFICE

COOKLINE

COOLER

STOR.JAN.DRY STOR.

COOKLINE

HEATING PLANT

OFFICE

C O

N

FE

R

EN

C E

R O

O M

OFFICE

OPEN OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE

OFFICE

OPEN OFFICE OFFICE

WORK

ROOM

OPEN OFFICE

SERVER

ROOM

COMPUTER

ROOM

COMPUTER

LIBRARY

OFFCE

VEST.

STOR.

UNIT SHOP

AUTOMOTIVE

SHOP

STOR.

MEDIA ROOM

MANUALS

OFFICE

OFFICE

CLASSROOM

WOMEN'S

LOCKERS

JAN.

ELEV.

EQUIP.

CORRIDOR STOR. STOR. AIR COMP.ENGINE DYNO. IN-FLOOR DYNO.

DIESEL SHOP

UNIT SHOP

STOR. STOR. OFFICE

OFFICE

MANUALS

SHOWER

MEDIA ROOM

CLASSROOM

LOCKERS

MEN'S

COMMONS

BOOKSTORE

WORK ROOM

SHIP / RECEIVING

ELEC. CHILLER MECH.

RM

MECH.

HALLCONF.OFFICE

BED LAB

CLASSROOM

CONFERENCE

OFFICE

OFFICE OFFICE

OFFICE

CLASSROOM

BED LAB

OFFICE

RESOURCE

CENTER

VEST.CONCOURSECONCOURSE

CONFERENCE

STOR. / JAN.

MEN'S

W O

M

EN

'S OFFICE

PHYSICAL

THERAPY

HEALTH

OCCUPATION

LAB RADIOLOGY

CERTIFIED

NURSING

ASSISTANT DENTAL LAB MEDICAL LAB

DENTAL E-RAY STOR. OFFICE

ELEC.

X-RAYT.R.OFFICE

DATA ROOM

OFFICE

OFFICERADIOLOGYOFFICEOFFICESTOR.

OFFICE OFFICE

BOOKSTORE

ENTRY

CORRIDOR

CLASSROOM CLASSROOM

SHOP

CLASSROOM

CLASSROOM

OFFICE

STOR.ELEC. / STOR.

WOMEN'S

JAN.

MEN'S

STOR.CLASSROOM

OFFICE

STOR.

STOR.STOR.

SHOP

OFFICE

CONF.

UNISEX

CONF.

OFFICE OFFICE

CLASSROOM

STORAGE

1016 1018 P

1018 Q

1018 R

OFFICE

FD

DN

UP

UP

UP

DN

UP

02.08

02.08

02.08

02.08

02.08

02.08

02.08

02.08

02.08

02.08

DEMOLITION PLAN LEGEND

EXISTING CONSTRUCTION

TO BE DEMOLISHED

EXISTING FLOOR FINISH

TO BE REMOVED. PREPARE

EXISTING SLAB FOR NEW FINISH

EXISTING CONCRETE SLAB

TO BE REMOVED

EXISTING CEILING, LAY-IN AND

GRID TO BE REMOVED.

EXISTING CEILING, GYP TO BE

REMOVED.

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

DFCM APPROVAL STAMP

D101

OVERALL

DEMO PLAN

LEVEL 1 -

MAIN

BUILDING

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

1/32" = 1'-0"1 LEVEL 1 FLOOR DEMO PLAN

MAIN BUILDING

KEY PLAN

(BARLOW BUILDING)

KEYED NOTES

02.08 REMOVE EXISTING FRAME & GLAZING

GENERAL NOTES - DEMO

1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND

AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS

2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW

CONSTRUCTION

3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION

4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION

5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION

6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC...

7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR

ADJACENT AREAS

8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303)

9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION

DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION

10 GENERAL CONTRACTOR TO CONSULT A WALK THROUGH W/ OWNER & ARCHITECT PRIOR TO COMMENCING DEMOLITION TO IDENTIFY ITEMS NOT LISTED AS 'REMOVE & PRESERVE FOR RE-USE' THAT SHOULD BE SALVAGED AND/OR RESERVED

FOR OWNER'S REUSE IN OTHER PARTS OF THE BUILDING

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

STUDENT

COMMONSVEST.

OFFICE OFFICE

CONF.

T.R.

OFFICE

STOR.

CLOSET

ADMIN. ASSIST. /

WAITING

SHOP

WELDING

COMPRESSOR

WOMEN'S MEN'S

JAN.

CONF. CLASSROOM VEST.

CLASSROOM STOR.

STOR.

STOR.

CORRIDORVEST.

NAILS

CLASSROOM

OFFICE

NAILS SALON

VOCATIONAL

ROOM

CORRIDOR

CLASSROOM

OFFICE MEDIA

STOR.

HAIR SALON

WEST

VOCATIONAL

ROOM

T.R.

HAIR SALON

EAST

VOCATIONAL

ROOM

ESTHETICIAN

ROOM

ESTHETICIAN

ROOM

ESTHETICIAN

ROOM

ESTHETICIAN

ROOM

ES

TH

ET

IC

IA

N

A R

EA

H

A

LL

EXERCISE ROOM EXERCISE ROOM

CORRIDOR

COSMETOLOGY

VOCATIONAL

ROOM

BREAK ROOM

OFFICE OFFICE

D

IS

PE

N

SA

R

Y

RECEP.

RETAILWAITING

VEST. VEST.

OFFICEOFFICE

CLASSROOM CLASSROOM

CLASSROOM

OFFICE OFFICE

HALL

OFFICE OFFICE OFFICE OFFICE

STOR.

STAFF

RESOURCE

WAITING

ELEC. OFFICE

OFFICE

OFFICE

OFFICEOFFICE

OFFICE

OFFICE

MEN'S

LOCKER /

SHOWER

LOCKER /

SHOWER

WOMEN'S

JAN.

STOR.

OFFICE

MAINTENANCE

SHOP

MAINENANCE

LAB

COMPRESSOR

ROOM

STOR. CLASSROOM

OFFICE OFFICE

MEDIA CENTER

CLASSROOM

T.R. T.R.

WELDING

STOR.

TESTING ROOM

OFFICE

IT

TESTING

OFFICE

OFFICE

OFFICE

OFFICE TEST

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

BOARD ROOM

OFFICE OFFICE

WOMEN'S MEN'S

RECEPTION AREA

OFFICE

RECEPTION AREA

JAN.

OPEN OFFICEOFFICE

CONF.

OFFICE

KITCHEN OFFICE

STOR. STOR.

CORRIDOR

CORRIDOR

CORRIDOR

MEN'S

ELEC.

WOMEN'S

JAN.

STOR.

DINNING DINNING ROOM

COOKLINE

COOKLINE

OFFICE

COOKLINE

COOLER

STOR.JAN.DRY STOR.

COOKLINE

HEATING PLANT

OFFICE

C O

N

FE

R

EN

C E

R O

O M

OFFICE

OPEN OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE OFFICE

OFFICE

OFFICE

OPEN OFFICE OFFICE

WORK

ROOM

OPEN OFFICE

SERVER

ROOM

COMPUTER

ROOM

COMPUTER

LIBRARY

OFFCE

VEST.

STOR.

UNIT SHOP

AUTOMOTIVE

SHOP

STOR.

MEDIA ROOM

MANUALS

OFFICE

OFFICE

CLASSROOM

WOMEN'S

LOCKERS

JAN.

ELEV.

EQUIP.

CORRIDOR STOR. STOR. AIR COMP.ENGINE DYNO. IN-FLOOR DYNO.

DIESEL SHOP

UNIT SHOP

STOR. STOR. OFFICE

OFFICE

MANUALS

SHOWER

MEDIA ROOM

CLASSROOM

LOCKERS

MEN'S

COMMONS

BOOKSTORE

WORK ROOM

SHIP / RECEIVING

ELEC. CHILLER MECH.

RM

MECH.

HALLCONF.OFFICE

BED LAB

CLASSROOM

CONFERENCE

OFFICE

OFFICE OFFICE

OFFICE

CLASSROOM

BED LAB

OFFICE

RESOURCE

CENTER

VEST.CONCOURSECONCOURSE

CONFERENCE

STOR. / JAN.

MEN'S

W O

M

EN

'S OFFICE

PHYSICAL

THERAPY

HEALTH

OCCUPATION

LAB RADIOLOGY

CERTIFIED

NURSING

ASSISTANT DENTAL LAB MEDICAL LAB

DENTAL E-RAY STOR. OFFICE

ELEC.

X-RAYT.R.OFFICE

DATA ROOM

OFFICE

OFFICERADIOLOGYOFFICEOFFICESTOR.

OFFICE OFFICE

BOOKSTORE

ENTRY

CORRIDOR

CLASSROOM CLASSROOM

SHOP

CLASSROOM

CLASSROOM

OFFICE

STOR.ELEC. / STOR.

WOMEN'S

JAN.

MEN'S

STOR.CLASSROOM

OFFICE

STOR.

STOR.STOR.

SHOP

OFFICE

CONF.

UNISEX

CONF.

OFFICE OFFICE

CLASSROOM

STORAGE

1016 1018 P

1018 Q

1018 R

OFFICE

FD

DN

UP

UP

UP

DN

UP

CW4

A201 D1

A201

D4

A201 A1

A201C1

SF2

SF2

SF1

CW21

CW20

CW19

CW19

CW7

SF8

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

DFCM APPROVAL STAMP

A101

OVERALL

PLAN LEVEL

1 - MAIN

BUILDING

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

1/32" = 1'-0"1 LEVEL 1 FLOOR PLAN

MAIN BUILDING

KEY PLAN

(BARLOW BUILDING)

GENERAL NOTES - FLOOR PLAN

1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN

CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK

2 DO NOT SCALE THE DRAWINGS

8 SEE SHEET SERIES A600 FOR WINDOW TYPES

9 SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS

10 SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION

11 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN

ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

LEVEL 01

100' - 0"

LEVEL 02

114' - 6"

SF2 SF2 SF1

08.20 02.28

02.65

08.20

E01

LEVEL 01

100' - 0"

LEVEL 02

114' - 6"

LEVEL 01 - LOW

97' - 8"

CW4

02.66 08.2202.28

02.65

D5

A550

LEVEL 01

100' - 0"

LEVEL 02

114' - 6"

LEVEL 01 - LOW

97' - 8"

2'

- 1

1" 7'

- 5

2'

- 6

"SF8

CW7

02.65

08.18

08.22 02.2808.20

LEVEL 01

100' - 0"

LEVEL 02

114' - 6"

CW21 CW20 CW19 CW19

08.22 02.28

02.65

08.22

08.22 08.22

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

DFCM APPROVAL STAMP

A201

EXTERIOR

ELEVATIONS

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

1/4" = 1'-0"D1 ELEVATION SF1, SF2

1/4" = 1'-0"D4 ELEVATION CW4

1/4" = 1'-0"A1 ELEVATION CW7, SF8

1/4" = 1'-0"C1 ELEVATION CW19, CW20, CW21

GENERAL NOTES - EXTERIOR ELEVATIONS

1 ALL EXPOSED STRUCTURAL EXTERIOR STEEL SHALL BE GALVANIZED WITHOUT CHROMATE COATING, SHOP PRIMED WITH

HIGH PERFORMANCE COATING

2 SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES

3 SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES

4 SEE SHEET SERIES A500 FOR ARRISCRAFT AND EIFS CORNICE PROFILES

5 SEE SHEET SERIES A500 FOR EXTERIOR RAILING TYPES

6 SEE SHEET A600 WINDOW SURROUND TYPES (WS - #)

KEYED NOTES

02.28 EXISTING WALLS TO REMAIN. PATCH, REPAIR, & TOUCH-UP WALL AS REQ'D

02.65 EXISTING METAL FASCIA AND SOFFIT TO REMAIN; PROTECT, PATCH AND REPAIR AS REQUIRED.

02.66 EXISTING COLUMN IN FRONT OF GLAZING TO REMAIN, REF. PLANS. PROTECT AS REQUIRED.

08.18 REPLACE EXISTING GLAZING AND FRAMING W/ NEW CURTAINWALL SYSTEM; SEE ADD ALTERNATE #1

08.20 STOREFRONT SYSTEM, MATCH EXISTING COLOR; RE: WINDOW SCHEDULE AND DETAILS.

08.22 CURTAINWALL SYSTEM, MATCH EXISTING COLOR; RE. WINDOW SCHEDULE AND DETAILS

ADD ALTERNATE #01

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

EXISTING CONCRETE CURB;

PROTECT AND REPAIR AS

NECESSARY.

THERMALLY BROKEN ALUMINUM

CURTAINWALL MULLION, SEALANT AND

BACKER ROD ENTIRE PERIMETER

BOTH SIDES; SHIM AS NEEDED.

1" INSULATED GLAZING; RE

EXTERIOR GLAZING SCHEDULE.

DRIP EDGE FLASHING

EXISTING INTERIOR PARTITION

W/ BATT INSULATION; PROTECT

AND REPAIR AS NECESSARY

1/2" SOLID SURFACE WINDOW SILL,

MITER CORNER, EASED SQUARE

EDGES; ADHERED TO WALL WITH

HEAVE DUTY ADHESIVE

1 1 /2"

0' - 3 3/4"

0'

- 2

EXISTING BRICK VENEER ASSEMBLY

W/ METAL FRAME BACKING; PROTECT

AND REPAIR AS NECESSARY.

1" INSULATED GLAZING; REF.

EXTERIOR GLAZING SCHEDULE

THERMALLY BROKEN ALUMINUM

CURTAINWALL MULLION, SEALANT AND

BACKER ROD ENTIRE PERIMETER

BOTH SIDES; SHIM AS NEEDED.

EXISTING GYPSUM WALL BOARD,

PAINTED; PROTECT AND REPAIR AS

NECESSARY.

EXISTING INTERIOR WALL;

REF. DIMENSION PLANS

EXISTING METAL INSULATED SOFFIT;

PROTECT AND REPAIR AS NECESSARY.

THERMALLY BROKEN ALUMINUM

CURTAINWALL MULLION, SEALANT AND

BACKER ROD ENTIRE PERIMETER BOTH

SIDES; SHIM AS NEEDED.

FOIL-FACED MINERAL WOOL INSULATION

BEHIND SPANDREL GLAZING; FOIL-TAPE

TO MULLION, TYP.

SPANDREL GLAZING; REF. EXTERIOR

GLAZING SHEET

AIR GAP

1" MIN

1 1/2"x1 1/2" BREAK METAL TRIM COVER

TO MATCH METAL PANEL SOFFIT

EXISTING ACT CEILING, REMOVE AND

PROTECT DURING WINDOW REPLACEMENT.

REPLACE GRID EDGE AS NEEDED.

THERMALLY BROKEN ALUMINUM

CURTAINWALL MULLION, SEALANT AND

BACKER ROD ENTIRE PERIMETER BOTH

SIDES; SHIM AS NEEDED.

1" INSULATED GLAZING ; RE. EXTERIOR

GLAZING SCHEDULE.

FOIL-FACED MINERAL WOOL INSULATION

BEHIND SPANDREL GLAZING; FOIL-TAPE

TO MULLION, TYP.

SPANDREL GLAZING; REF. EXTERIOR

GLAZING SHEET

AIR GAP

1" MIN.

MANUAL ROLLER TUBE AND SHADE

ASSEMBLY, INSTALL PER MANUF

THERMALLY BROKEN ALUMINUM

CURTAINWALL MULLION, SEALANT

AND BACKER ROD ENTIRE PERIMETER

BOTH SIDES; SHIM AS NEEDED.

1" INSULATED GLAZING; RE.

EXTERIOR GLAZING SCHEDULE.

EXISTING BRICK VENEER ASSEMBLY W/

METAL FRAME BACKING; PROTECT AND

REPAIR AS NECESSARY.

THERMALLY BROKEN ALUMINUM

CURTAINWALL MULLION, SEALANT AND

BACKER ROD ENTIRE PERIMETER BOTH

SIDES; SHIM AS NEEDED.

1" INSULATED GLAZING; REF. EXTERIOR

GLAZING SCHEDULE.

WEATHER BARRIER, FIELD VERIFY;

PROTECT AND REPAIR AS NECESSARY.

EXISTING GYPSUM WALL BOARD ASSEMBLY;

PROTECT AND REPAIR AS NECESSARY

1/2" SOLID SURFACE WINDOW SILL, MITER

CORNER, EASED SQUARE EDGES; ADHERED

TO WALL WITH HEAVE DUTY ADHESIVE

EXISTING INSULATED METAL PANEL;

PROTECT AND REPAIR AS NECESSARY.

EXISTING METAL FRAMING W/ INSULATION;

PROTECT AND REPAIR AS NECESSARY

THERMALLY BROKEN ALUMINUM CURTAINWALL

MULLION, SEALANT AND BACKER ROD ENTIRE

PERIMETER BOTH SIDES; SHIM AS NEEDED.

TWO-PIECE HEAD FLASHING W/

CONTINUOUS BUTYL FLASHING BETWEEN

PIECES. TO MATCH GLAZING FINISH

EXTERIOR CAP TRIM W/ HEMMED EDGE FASTENED W/

POP RIVETS @ 8" O.C. TO MATCH EXISTING FINISH

FASTEN FLASHING W/ LOW PROFILE THROUGH

FASTENER W/ CONTINUOUS BUTYL SEAL

CONTINUOUS BUTYL SEALANT; MARRIAGE BED

TO VERTICAL PANEL JOINT AS ALLOWABLE

FOIL-FACED MINERAL WOOL INSULATION BEHIND

SPANDREL GLAZING; FOIL-TAPE TO MULLION, TYP.

SPANDREL GLAZING; REF. EXTERIOR

GLAZING SHEET

1" MIN.

EXISTING CONCRETE FOUNDATION;

PROTECT AND REPAIR AS NEEDED.

SILL FLASHING

THERMALLY BROKEN ALUMINUM

STOREFRONT SILL, SEALANT AND

BACKER ROD ENTIRE PERIMETER BOTH

SIDES; SHIM AS NEEDED.

FOIL-FACED MINERAL WOOL INSULATION

BEHIND SPANDREL GLAZING; FOIL-TAPE

TO MULLION, TYP.

METAL STUD WALL ASSEMBLY TO

REMAIN, PATCH AND REPAIR AS NEEDED

GYPSUM WALL BOARD TO REMAIN, ,

PATCH AND REPAIR AS NEEDED

1" SPANDREL GLAZING; RE. EXTERIOR

GLAZING SCHEDULE

0'

- 2

0' - 1"

1" MIN.

GLAZING; RE: EXTERIOR

GLAZING SCHEDULE

EXISTING STUD FRAMING

AND INSULATION TO REMAIN

SPANDREL GLAZING W/ FOIL FACE

MINERAL WOOL INSULATION

EXISTING WALL BASE TO REMAIN

EXISTING GYP. BOARD, PAINT TO

BE TOUCHED UP AS NEEDED

FOIL-FACED MINERAL WOOL INSULATION

BEHIND SPANDREL GLAZING; FOIL-TAPE

TO MULLION, TYP.

1/2" SOLID SURFACE WINDOW SILL, MITER

CORNER, EASED SQUARE EDGES; ADHERED TO

WALL WITH HEAVE DUTY ADHESIVE

JOINT SEALANT

EXISTING COLUMN WRAP TO REMAIN,

PROTECT AND REPAIR AS NECESSARY

EXISTING BREAK METAL WALL END CAP TO

REMAIN, PROTECT AND REPAIR AS NECESSARY

1/2" SOLID SURFACE WINDOW SILL, MITER

CORNER, EASED SQUARE EDGES; ADHERED TO

WALL WITH HEAVE DUTY ADHESIVE

EXISTING INTERIOR WALL TO REMAIN

PATCH AND REPAIR AS NECESSARY

EXISTING INSULATED METAL PANEL;

PROTECT AND REPAIR AS NECESSARY.

EXISTING METAL FRAMING W/ INSULATION;

PROTECT AND REPAIR AS NECESSARY

THERMALLY BROKEN ALUMINUM STOREFRONT

MULLION, SEALANT AND BACKER ROD ENTIRE

PERIMETER BOTH SIDES; SHIM AS NEEDED.

TWO-PIECE HEAD FLASHING W/

CONTINUOUS BUTYL FLASHING BETWEEN

PIECES. TO MATCH GLAZING FINISH

EXTERIOR CAP TRIM W/ HEMMED EDGE FASTENED W/

POP RIVETS @ 8" O.C. TO MATCH EXISTING FINISH

FASTEN FLASHING W/ LOW PROFILE THROUGH

FASTENER W/ CONTINUOUS BUTYL SEAL

CONTINUOUS BUTYL SEALANT; MARRIAGE BED

TO VERTICAL PANEL JOINT AS ALLOWABLE

SPANDREL GLAZING; REF. EXTERIOR

GLAZING SHEET

EXISTING CONCRETE CURB;

PROTECT AND REPAIR AS

NECESSARY.

THERMALLY BROKEN ALUMINUM

STOREFRONT SILL, SEALANT AND

BACKER ROD ENTIRE PERIMETER

BOTH SIDES; SHIM AS NEEDED.

1" INSULATED GLAZING; RE

EXTERIOR GLAZING SCHEDULE.

DRIP EDGE FLASHING

EXISTING INTERIOR PARTITION

W/ BATT INSULATION; PROTECT

AND REPAIR AS NECESSARY

1/2" SOLID SURFACE WINDOW SILL,

MITER CORNER, EASED SQUARE

EDGES; ADHERED TO WALL WITH

HEAVE DUTY ADHESIVE

1 1 /2"

0'

- 2

0' - 3 3/4"

EXISTING BRICK VENEER ASSEMBLY W/

METAL FRAME BACKING; PROTECT AND

REPAIR AS NECESSARY.

THERMALLY BROKEN ALUMINUM

STOREFRONT MULLION, SEALANT AND

BACKER ROD ENTIRE PERIMETER BOTH

SIDES; SHIM AS NEEDED.

1" INSULATED GLAZING; REF. EXTERIOR

GLAZING SCHEDULE.

WEATHER BARRIER, FIELD VERIFY;

PROTECT AND REPAIR AS NECESSARY.

EXISTING GYPSUM WALL BOARD ASSEMBLY;

PROTECT AND REPAIR AS NECESSARY

1/2" SOLID SURFACE WINDOW SILL, MITER

CORNER, EASED SQUARE EDGES; ADHERED

TO WALL WITH HEAVE DUTY ADHESIVE

GLAZING; RE: EXTERIOR

GLAZING SCHEDULE

EXISTING STUD FRAMING

AND INSULATION TO REMAIN

SPANDREL GLAZING W/ FOIL FACE

MINERAL WOOL INSULATION

EXISTING WALL BASE TO REMAIN

EXISTING GYP. BOARD, PAINT TO

BE TOUCHED UP AS NEEDED

FOIL-FACED MINERAL WOOL INSULATION

BEHIND SPANDREL GLAZING; FOIL-TAPE

TO MULLION, TYP.

1/2" SOLID SURFACE WINDOW SILL, MITER

CORNER, EASED SQUARE EDGES; ADHERED TO

WALL WITH HEAVE DUTY ADHESIVE

JOINT SEALANT

3" = 1'-0"B2 DETAIL - CW HEAD @ INSULATED METAL PANEL

3" = 1'-0"B5 DETAIL - CW JAMB @ BRICK

3" = 1'-0"A2 DETAIL - CW HEAD @ METAL PANEL SOFFIT

3" = 1'-0"A5 DETAIL - CW JAMB @ BRICK RETURN

3" = 1'-0"B6 DETAIL - CW SILL @ GRADE

3" = 1'-0"C6 DETAIL - SF SILL @ FOUNDATION GRADE

3" = 1'-0"A6 DETAIL - CW SILL @ RAISED FOUNDATION

3" = 1'-0"A3 DETAIL - CW CEILING TERMINATION @ MULLION

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

DFCM APPROVAL STAMP

A550

EXTERIOR

GLAZING

DETAILS

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

1 1/2" = 1'-0"B3 DETAIL - CW SILL @ FURRED SPANDREL

3" = 1'-0"D5 PLAN DETAIL @ COLUMN

3" = 1'-0"C2 DETAIL - SF HEAD @ INSULATED METAL PANEL

3" = 1'-0"D6 DETAIL - SF SILL @ RAISED FOUNDATION

3" = 1'-0"C5 DETAIL - SF JAMB @ BRICK

1 1/2" = 1'-0"C3 DETAIL - SF SILL @ FURRED SPANDREL

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

STOREFRONT SYSTEM

AREA: 105 SF.

B6

A550

1' - 10 3/4" 3' - 0" 5' - 1 1/4"

1'

- 6

6'

- 2

2'

- 1

0"

10' - 0"

6"

P1 P1

G2

G2

G2

A3

A550

SIM

C5

A550

C2

A550

G1

E01

G2

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

STOREFRONT SYSTEM

AREA: 105 SF.

C6

A550

G1

P1P1

G1

P1 P1

6"

1'

- 6

6'

- 2

2'

- 1

0"

5' - 0" 5' - 0"

10' - 0"

A3

A550

SIM

C2

A550

B5

A550 C3

A550

A2

A550

A5

A550

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

CURTAIN WALL SYSTEM

AREA: 210 SF.

A6

A550

A3

A550

EXISTING COLUMN IN FRONT OF GLAZING

TO REMAIN, PROTECT AS REQUIRED

P1

G1

P1

G1

P1

G1

P1

G1

6" 2'

- 4

2'

- 1

0" 7'

- 8

20' - 0"

5' - 0"5' - 0"5' - 0"5' - 0"

D5

A550

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

CURTAIN WALL SYSTEM

AREA: 105 SF.

G1

P1 P1

G1

P1P1

1'

- 6

6'

- 2

2'

- 1

0"

6"

5' - 0" 5' - 0"

10' - 0"

A3

A550

B5

A550

B2

A550

C6

A550

B3

A550

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

CURTAIN WALL SYSTEM

AREA: 210 SF.

G1

P1 P1

G1

P1

G1

P1

G1

P1P1P1P1

5' - 0" 5' - 0" 5' - 0" 5' - 0"

20' - 0"

1'

- 6

6'

- 2

2'

- 1

0"

6"

A3

A550 B5

A550

B2

A550

C6

A550

B3

A550

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

CURTAIN WALL SYSTEM

AREA: 81 SF.

G1 G1

P1 P1

P1 P1

1'

- 6

6'

- 2

2'

- 1

0"

6"

7' - 8"

3' - 10" 3' - 10"

B5

A550

B2

A550

C6

A550

A3

A550

B3

A550

SPANDREL GLASS PANEL.

DARK BRONZE.

CURTAIN WALL SYSTEM

AREA: 736 SF.

G1

P1P1

G1

P1 P1

G1

P1

P1P1

P1

G1G1

P1

P1P1

G1

P1

P1

G1

P1

P1

G1

P1

P1

G1

P1

P1

G1

P1

2'

- 1

0" 7'

- 6

2'

- 6

58' - 1"

4' - 1"

TYP.

5' - 0" 4' - 0"

A3

A550

A5

A550

A5

A550

OPP

G1

P1P1

G1

P1P1

A2

A550

B6

A550

B3

A550

SPANDREL GLASS PANEL.

DARK BRONZE ALUM.

STOREFRONT SYSTEM

AREA: 53 SF.

G1

P1

2'

- 1

0" 7'

- 8 "10

6"

5' - 0"

A3

A550

SIM

C2

A550

D6

A550

1/4" = 1'-0"D1 SF 1

1/4" = 1'-0"D2 SF 2 (2X)

1/4" = 1'-0"D3 CW 4

1/4" = 1'-0"C2 CW 7

1/4" = 1'-0"C5 SF 8

1/4" = 1'-0"D4 CW 19 (2X)

1/4" = 1'-0"D5 CW 20

1/4" = 1'-0"D6 CW 21

3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:

title:

revisions :

p r o j e c t # :

d a t e :

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND

DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS

NOT INTENDED FOR CONSTRUCTION, RECORDING

PURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING

ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &

MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE

COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN

WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS

WRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

DFCM APPROVAL STAMP

A605

EXTERIOR

GLAZING

SCHEDULE

26.0185

07/16/2026

550 E 300 S, KAYSVILLE, UT 84037

Davis Tech Main Building Glazing

GLAZING SCHEDULE

G1 1" DOUBLE PANE INSULATED GLAZING - LOW E

G2 1" DOUBLE PANE INSULATED TEMPERED GLAZING

P1 1" DOUBLE PANE INSULATED GLAZING - HEAT TREATED

GLAZING GENERAL NOTES

1 CONTRACTOR TO CONFIRM AND VERIFY QUANTITIES OF ALL GLAZING TYPES

2 ALL GLAZING DIMENSIONS TO BE FIELD VERIFIED PRIOR TO BIDDING, ORDERING, AND INSTALLING

3 ROUGH OPENING REQUIREMENTS SHALL BE COORDINATED WITH WINDOW MANUFACTURER, TYP

4 ALL CURTAINWALL SYSTEMS REQUIRE DELEGATED DESIGN SUBMITTAL

5 SEE DOOR SCHEDULE FOR SCHEDULED GLAZING WITHIN DOORS

6 SEE FLOOR PLAN AND ELEVATIONS FOR WALL TYPE AND MATERIAL CONDITION IN REFERING TO WINDOW AND

STOREFRONT DETAILS

7 SAFETY GLAZING SHALL BE INSTALLED IN HAZARDOUS LOCATIONS WITH IBC 2406.4, THIS INCLUDES GLAZING IN WINDOW, STOREFRONT, AND DOOR TYPES.

FRAME FINISH SCHEDULE

CW4 DARK BRONZE

CW7 DARK BRONZE

CW19 DARK BRONZE

CW20 DARK BRONZE

CW21 DARK BRONZE

SF1 DARK BRONZE

SF2 DARK BRONZE

ADD ALTERNATE #01

ALL DOOR HANDLES & HARDWARE USED ON THE PROJECT MUST NOT REQUIRE PINCHING, TIGHT GRASPING, OR TWISTING OF THE WRIST IN ORDER TO OPERATE, IN ACCORDANCE WITH 2018 IBC 1010.1.9.1

DOOR SCHEDULE - ALL

DOOR

NUMBER

ROOMS DOOR DIMENSIONS DOOR FRAME FIRE

RATING

PANIC

HW

CARD

ACCESS ELEC HW CLOSER LOCKING

OCC

INDICATOR

SMOKE

SEAL HW SET

DOOR

NUMBER COMMENTSTO RM # WIDTH HEIGHT THK TYPE MATERIAL FINISH TYPE MATERIAL FINISH

LEVEL 01

E01 3' - 0" 7' - 0 3/4" 2" DT1 SF SINGLE GLASS MATCH EXISTING FT1 ALUMINUM MATCH EXISTING ● ● 01 E01

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

G000 - COVER SHEET
G001 - INDEX, GENERAL NOTES, LOCATION MAP, LEGENDS
D101 - OVERALL DEMO PLAN LEVEL 1 - MAIN BUILDING
A101 - OVERALL PLAN LEVEL 1 - MAIN BUILDING
A201 - EXTERIOR ELEVATIONS
A550 - EXTERIOR GLAZING DETAILS
A605 - EXTERIOR GLAZING SCHEDULE

File details come from the government source that posted it. Updated .