ROH00760_OH0046ZZ_Dwg04_E101.pdf
PDF 379 KB Posted
- Attached to
- Cooling Tower Replacement Federal contract opportunity
- Solicitation number
- 47PF0019R0099
About this file
RFP 47PF0019R0099 Drawing 04
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Pre-Bid_Walkthrough_Q&A_and_Attendance_Sheets.pdf | ||
| RFP_47PF0019R0099.pdf | ||
| ROH00760_OH0046ZZ_Dwg03_H201.pdf | ||
| (specs)_ROH00760_Cooling_Tower_100pct_Specifications_2019-04-17.pdf | ||
| ROH00760_OH0046ZZ_Dwg01_G000.pdf | ||
| ROH00760_OH0046ZZ_Dwg02_A101.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
M
M
M
M
M
WP
R
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
R
R
R
R
R
R
R
V
F
D
V
F
D
CT1
CT2
MCCB
SWITCHBOARD
BR1
50' +
R
R
R
R
R
R
R
R
SOLID SYMBOLS WITH SUBSCRIPT "RD" INDICATE RELOCATED DEVICES.
DASHED SYMBOLS WITH SUBSCRIPT "REL" INDICATE DEVICES TO BE RELOCATED.
DASHED LINES INDICATE DEVICES TO BE REMOVED.6.
WALL MOUNTED LUMINAIRE
-AS NOTED) "3R" DENOTES NEMA "3R" ENCLOSURE,
SAFETY SWITCH (SWITCH SIZE, FUSE SIZE, NO. OF POLES
DUPLEX RECEPTACLE, WEATHERPROOF AND GROUND
SINGLE POLE SWITCH
60/45/3
3R, NF
M
WP
S
R
VARIABLE FREQUENCY DRIVE
FAULT INTERRUPTER
"NF" DENOTES NONFUSED
MOTOR (BY DIVISION 1-25)
DUPLEX RECEPTACLE
SEE DRAWINGS
60"
SEE DRAWINGS
MOUNTING HEIGHTS ARE TO TOP U.N.O.
SOME SYMBOLS MAY NOT BE USED.
SYMBOL
2.
1.
DESCRIPTION NOTED OTHERWISE
HEIGHT UNLESS
MOUNTING
VFD
SYMBOLS LIST FOR PLANS
1. REFER TO DRAWINGS AND SPECIFICATIONS OF OTHER
CONSTRUCTION TRADES FOR ADDITIONAL ELECTRICAL WORK
INCLUDED IN THIS CONTRACT.
2. COORDINATE EXACT LOCATIONS OF EQUIPMENT WITH OTHER
CONSTRUCTION TRADES. VERIFY EXACT WIRING AND CONNECTION
REQUIREMENTS WITH SUBMITTAL DOCUMENTS BEFORE
INSTALLATION. ALL ELECTRICAL WORK SHOWN HERE SHALL BE
VERIFIED AND COORDINATED IN FIELD BEFORE INSTALLATION.
3. ALL DEVICES SHOWN ON THE EXTERIOR OF THE BUILDING SHALL BE
WEATHERPROOF TYPE.
4. PROVIDE ALL FINAL POWER CONNECTIONS TO EQUIPMENT. PROVIDE
ALL CONDUIT, DEVICE BOXES, AND CONTROL WIRING TO EQUIPMENT
UNLESS NOTED OTHERWISE.
GENERAL NOTES
5. SOLID SYMBOLS WITH SUBSCRIPT "R" INDICATE EXISTING DEVICES TO REMAIN.
COORD. HT
COORD. HT
COORD. HT
FLEXIBLE METAL CONDUIT OR LIQUID-TIGHT FLEXIBLE
METAL CONDUIT
HOME RUN BRANCH CIRCUIT (OVERHEAD) ----
FUSIBLE SWITCH WITH FUSES (SIZE AS NOTED)
100/3
MAGNETIC MOTOR STARTER (STARTER SIZE, FUSE SIZE,
NO. OF POLES -AS NOTED) "3R" DENOTES NEMA "3R"
ENCLOSURE, "NF"=NONFUSED
3R, NF
1/25/3
EXISTING MOTOR CONTROL CENTER MCCB
AMP, 480 V, 3 Ø, 3 WIRE
C
PARTIAL ONE LINE DIAGRAM
EXISTING
NTS
1 2 3 4 5 6
70A
100/3
20A
30/3
20A
30/3
70A
100/3
20A
30/3
COOLING
TOWER 1
M
3R
100/NF/3
VFD
M
3R
100/NF/3
VFD
M
3R
30/NF/3
3R
30/NF/3
20A
30/3
M
3R
30/NF/3
3R
30/NF/3
40 HP
COOLING
TOWER 1
10 HP
COOLING
TOWER 1
BASIN HEATER
10KW
COOLING
TOWER 2
40 HP
COOLING
TOWER 2
10 HP
COOLING
TOWER 2
BASIN HEATER
10KW
S E
N S
I T
I V
E
B
U T
N C
L A
S S
I F
I E
D
S
B U
P
R O
P E
R T
Y
O
F
T
H E
I T
D
S
A
T E
S
G
O V
E R
N M
E N
T
F
O R
F F
I C
I A
L
U
L Y
O
N
M
O V
E
T
H I
T
I C
E
P
R O
P E
R L
S
T R
C
U M
E N
W
H E
N
N
O
L O
N G
E
D E
D
General Services Administration
Public Buildings Service
Great Lakes Region
Design and Construction Division
John C. Kluczynski Federal Building
230 South Dearborn Street
Chicago , IL 60604
Columbus, OH, 43215
Kinneary U.S. Courthouse
100% Construction Documents
04-17-2019
ROH00760OH0046ZZ
COOLING TOWERS
GS-05P-17-SC-D-0010
47PF00-18-F-0076
A
M
Cooling Tower Replacement
ROH00760
KORDA
KORDA
85 Marconi Boulevard
MARK DATE DESCRIPTION
PROJECT NUMBER:
CHECKED BY:
DESIGNED BY:
1650 WATERMARK DRIVE
COLUMBUS, OHIO 43215
SUITE 200
DRAWN BY:
2017-0210
Iveta Moncolova
Enrique Kundla
E101
Floor Plan
ELECTRICAL
1/4" = 1'-0"
0 1 2 4
A
Cooling Tower Area Floor Plan
Demolition
1/4" = 1'-0"
0 1 2 4
B
Cooling Tower Area Floor Plan
New Work
CODED NOTES
1. PULLBOX TO REMAIN. PULLBOX MAY BE REUSED FOR NEW
CONDUCTORS.
2. BOND EQUIPMENT TO EXISTING GROUND CONDUCTOR WITH #4 BARE
COPPER CONDUCTOR.
3. GROUND CONDUCTOR AND GROUND ROD TO REMAIN.
4. REMOVE EXISTING STARTER CIRCUIT AND PROVIDE NEW FEEDER TO
EQUIPMENT.
5. 3 #10 AWG, 1 #8 AWG GROUND IN 0.75" CONDUIT.
6. 3 #1 AWG, 1 #8 AWG GROUND IN 1.25" CONDUIT.
7. REMOVE AND REPLACE DEVICE AND JUNCTION BOX. PROVIDE NEW
DEVICE IN JUNCTION BOX WITH WHILE-IN-USE COVER.
8. REMOVE EXISTING CONDUCTORS COMPLETELY BACK TO SOURCE.
CONTRACTOR MAY REUSE CONDUITS INSIDE BUILDING. CONTRACTOR
SHALL PROVIDE NEW CONDUIT ON EXTERIOR OF BUILDING FROM
PULLBOX TO LOAD. NOTE: CONTRACTOR SHALL PROVIDE NEW
CONDUCTORS FROM MCCB TO LOADS.
9. EXISTING HEAT TRACE TO BE REMOVED. REMOVE EXISTING
CONDUCTORS COMPLETELY BACK TO SOURCE. CONTRACTOR MAY
REUSE CONDUITS INSIDE BUILDING.
10. HEAT TRACE CONTROLLER. CONTRACTOR SHALL PROVIDE NEW
CONDUIT AND PULL BOX ON EXTERIOR OF BUILDING TO LOAD.
NOTE: CONTRACTOR SHALL PROVIDE NEW CONDUCTORS FROM BR1
TO LOADS. CIRCUIT TO EXISTING 120V, 20/1 CIRCUIT BREAKER IN
PANEL BR1.
11. APPROXIMATE LOCATION OF ELECTRICAL EQUIPMENT INSIDE
BUILDING.
COOLING
EXISTING
12345
D
DETAIL
EXISTING MOTOR CONTROL CENTER MCCB
N.T.S.
TOWER 2
EXHAUST
FAN
SPACE
NEW
EXHAUST
FAN
SPARE
SPACE
AIR
COMPR.1
AIR
COMPR.2
SPARE
BOILER
FEED
SYSTEM
VACUUM
PUMPS
SPARE
EXISTING
SUPPLY
SPARE
COOLING
TOWER 2
SPARE
AIR
CONDENSER
WATER
PUMP 2
COOLING
TOWER 1
BOILER 2
SPARE
CONDENS.
PUMPS
CONDENSER
WATER
PUMP 1
BASIN
HEATER 1
BASIN
HEATER 2
BUSSING
COOLING
TOWER 1
CHILLED
WATER
PUMP 1
CHILLED
WATER
PUMP 2
BOILER 1
| Sheets and Views |
| ROH00760 OH0046ZZ E101-Plot Sheet |
File details come from the government source that posted it.