PRO

INDUSTRIAL™

113.05

PRO-CRYL®

UNIVERSAL PRIMER

B66W00310 OFF WHITE

B66A00310 GRAY

B66N00310 RED OXIDE

Waterborne topcoat:

1-2 cts. Pro Industrial Acrylic or Pro Industrial DTM Acrlyic or Pro Industrial Multi-Surface Acrylic or Pro Industrial Pre-Catalyzed Waterbased Epoxy or Pro Industrial Waterbased Acrolon 100 or Pro Industrial Waterbased Catalyzed Epoxy

Solventborne topcoat:

1-2 cts. Pro Industrial High Performance Epoxy or Pro Industrial Urethane Alkyd

Pro Industrial Pro-Cryl Universal Primer B66W310 Off White is GREENGUARD GOLD certified for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg.

System Tested: (unless otherwise indicated) Substrate: Steel Surface Preparation: SSPC-SP10 1 ct. Pro Industrial Pro-Cryl Universal Primer 1 ct. Pro Industrial Acrylic

CHARACTERISTICS

Pro Industrial Pro-Cryl Universal Primer is an advanced technology, self cross-linking acrylic primer. It is rust inhibitive and designed for commercial, new construction and maintenance applications. It can be used as a primer under water-based or solvent-based high performance topcoats.

Rust inhibitive Single component Early moisture resistant Fast dry Low temperature application 40°F Interior and exterior use Suitable for use in USDA inspected facilities

Color: Off White, Gray, Red Oxide Recommended Spread Rate per coat:

Wet mils: 5.0 - 10.0 Dry mils: 1.8 - 3.6 ~Coverage: 160 - 320 sq ft/gal Approximate Theoretical coverage sq ft/gal (m2/L) @ 1 mil / 25 microns dft 577sq ft NOTE: Brush or roll application may require multiple coats to achieve maximum film thickness and uniformity of appearance.

Drying Time @ 6.0 mils wet 50% RH:

40°F 77°F 120°F To touch: 2 hrs 40 min 20 min Tack free: 8 hrs 2 hrs 1 hr To recoat: 16 hrs 4 hrs 2 hrs To cure: 45 days 30 days 14 days Drying time is temperature, humidity, and film thickness dependent.

Finish: Low sheen Flash Point: N/A Shelf Life: 36 months, unopened Store indoors at 40°F to 100°F.

Tinting: Do not tint

B66W310 (may vary by color) VOC (less exempt solvents):

96 g/L; 0.80 lb/gal As per 40 CFR 59.406 and SOR/2009-264, s.12

Volume Solids: 36% ± 2% Weight Solids: 49% ± 2% Weight per Gallon: 10.23 lb

9/2015 www.sherwin-williams.com continued on back

Adhesion:

Method: ASTM D4541 Result: 500 psi

Corrosion Weathering:

Method: ASTM D5894, 10 cycles, 3360 hours Result: Passes

Direct Impact Resistance:

Method: ASTM D2794 Result: >140 in. lbs.

Dry Heat Resistance*:

Method: ASTM D2485 Result: 200°F

Flexibility:

Method: ASTM D522, 180° bend, 1/4" mandrel Result: Passes

Moisture Condensation Resistance:

Method: ASTM D4585, 100°F, 1250 hours Result: Passes

Pencil Hardness:

Method: ASTM D3363 Result: H

Salt Fog Resistance:

Method: ASTM B117, 1250 hours Result: Passes

Provides performance comparable to products formulated In Lieu of Federal Specification: AA50557 and Paint Specification: SSPC-Paint 23.

RECOMMENDED SYSTEMS

As of 09/11/2015, Complies with:

OTC Yes LEED® 09 CI Yes SCAQMD Yes LEED® 09 NC Yes CARB Yes LEED® 09 CS Yes CARB SCM 2007 Yes LEED® 09 S Yes MPI 107,134 NGBS Yes

*Suitable for intermittent dry heat resistance up to 300°F when used as a system with Sher-Cryl HPA

The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.

APPLICATION

Refer to the SDS before using Temperature: 40°F minimum 120°F maximum (air, surface, and material) At least 5°F above dew point Relative humidity: 85% maximum

The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics. Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.

Reducer: Water

Airless Spray Pressure .................................... 2000 psi Hose ............................................ 1/4" ID Tip ...................................... .015" - .019" Filter ......................................... 60 mesh Reduction .................. Not recommended

Conventional Spray Gun .......................................... Binks 95 Fluid Nozzle Air Nozzle ...................................... 63PB Atomization Pressure .................... 60 psi Fluid Pressure ............................... 25 psi ReductionAs needed up to 5% by volume

Brush ........................... Nylon/Polyester Reduction .................. Not recommended

Roller ...................................3/8" woven ReductionAs needed up to 5% by volume

If specific application equipment is listed above, equivalent equipment may be substituted.

CLEANUP INFORMATION

Clean spills and spatters immediately with soap and warm water. Clean hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer's safety recommendations when using solvents.

HOTW 09/11/2015 B66W00310 32 96

KOR, FRC, SP

SURFACE PREPARATION

WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women.

Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.

Do not use hydrocarbon solvents for cleaning.

Iron & Steel - Minimum surface preparation is Hand Tool Cleaning per SSPC-SP2.

Remove all oil and grease from the surface per SSPC-SP1. For better performance, use Commercial Blast Cleaning per SSPC-SP6.

Aluminum - Remove all oil, grease, dirt, oxide and other foreign material per SSPC- SP1.Prime the area the same day as cleaned.

Galvanizing - Allow to weather a minimum of six months prior to coating. Solvent Clean per SSPC-SP1. When weathering is not possible, or the surface has been treated with chromates or silicates, first Solvent Clean per SSPC-SP1 and apply a test patch. Allow paint to dry at least one week before testing adhesion. If adhesion is poor, brush blasting per SSPC-SP7 is necessary to remove these treatments. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2, prime the area the same day as cleaned.

Previously Painted Surfaces - If in sound condition, clean the surface of all foreign material. Smooth, hard or glossy coatings and surfaces should be dulled by abrading the surface. Apply a test area, allowing paint to dry one week before testing adhesion. If adhesion is poor, additional abrasion of the surface and/or removal of the previous coating may be necessary. Retest surface for adhesion. If paint is peeling or badly weathered, clean surface to sound substrate and treat as a new surface as above. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.

APPLICATION PROCEDURES

Apply paint at the recommended film thickness and spreading rate as indicated on front page. Application of coating below minimum recommended spreading rate will adversely affect coating performance.

SAFETY PRECAUTIONS

Refer to the SDS sheets before use. FOR PROFESSIONAL USE ONLY Published technical data and instructions are subject to change without notice.

Contact your Sherwin-Williams representative for additional technical data and instructions.

PERFORMANCE TIPS

No painting should be done immediately after a rain or during foggy weather.

When using spray application, use a 50% overlap with each pass of the gun to avoid holidays, bare areas, and pinholes. Apply coating evenly while maintaining a wet edge to prevent lapping.

PRO INDUSTRIAL™