PRO
INDUSTRIAL™
113.07
DTM
ACRYLIC SEMI-GLOSS
B66W01151 Extra White B66W01153 Deep Base B66T01154 Ultradeep
Steel*:
2 cts. Pro Industrial DTM Acrylic Steel:
1 ct. Pro Industrial Pro-Cryl Primer or DTM Primer/Finish 1-2 cts. Pro Industrial DTM Acrylic Aluminum:
1-2 cts. Pro Industrial DTM Acrylic Concrete Block:
1 ct. Heavy Duty Blockfiller 1-2 cts. Pro Industrial DTM Acrylic Concrete/Masonry:
1 ct. Loxon Concrete & Masonry Primer 1-2 cts. Pro Industrial DTM Acrylic
Drywall 1 ct. ProMar 200 Primer 1-2 cts. Pro Industrial DTM Acrylic Galvanizing:
2 cts. Pro Industrial DTM Acrylic Prefinished Siding:(Baked-on finishes) 1 ct. DTM Bonding Primer 1-2 cts. Pro Industrial DTM Acrylic Wood, Exterior:
1 ct. Exterior Wood Primer 1-2 cts. Pro Industrial DTM Acrylic Wood, Interior:
1 ct. Premium Wall & Wood Primer 1-2 cts. Pro Industrial DTM Acrylic
System Tested: (unless otherwise indicated) Substrate: Steel Surface Preparation: SSPC-SP10 Finish: Pro Industrial DTM Acrylic, B66W01151 – 2 cts @ 3.0 mils dft/ct
CHARACTERISTICS
Pro Industrial DTM Acrylic coating is an interior/exterior, water based, corrosion resistant acrylic coating for light to moderate industrial use. Designed for new construction or maintenance use and can be used directly over prepared substrates.
Chemical resistant Corrosion resistant Fast dry Flash rust/early rust resistant Suitable for use in USDA inspected facilities
Color: most colors Recommended Spread Rate per coat:
Wet mils: 6.0 - 10.0 Dry mils: 2.5 - 4.0 Coverage: 160 - 255 sq ft/gal approximate Note: Brush or roll application may require multiple coats to achieve maximum film thickness and uniformity of appearance.
Drying Time @ 6.0 mils wet 50% RH:
@ 50°F @ 77°F @ 110°F To touch: 1 hr 20 min 10 min Tack free: 2 hrs 45 min 30 min To recoat: 2 hrs 1 hr 1 hr Drying time is temperature, humidity, and film thickness dependent.
Finish: 38-48@ 60° Semi-Gloss Flash Point: N.A.
Shelf Life: 36 months, unopened Store indoors at 40°F to 100°F.
Tinting with CCE:
Base oz/gal Strength Extra White 0-6 100% Deep Base 6-12 100% Ultradeep 10-12 100%
Extra White B66W01151
(may vary by color) VOC (less exempt solvents): Unreduced:
<50 g/L; 0.42 lb/gal As per 40 CFR 59.406 and SOR/2009-264, s.12 Volume Solids: 40 ± 2% Weight Solids: 51 ± 2% Weight per Gallon: 10.21 lb/gal ±2%
9/2015 www.sherwin-williams.com continued on back
Adhesion:
Method: ASTM D4541 Result: > 500 psi Corrosion Weathering:
Method: ASTM D5894, 1680 hours, 5 cycles Result: Rating 10N, per ASTM D714 for blistering Rating 9, per ASTM D1654 for corrosion Direct Impact Resistance:
Method: ASTM D2794 Result: >160 in. lb Dry Heat Resistance:
Method: ASTM D2485 Result: 300°F Flexibility:
Method: ASTM D522, 180° bend, 1/8" mandrel Result: Pass
Humidity Resistance:
Method: ASTM D4585, 1000 hours Result: Rating 10N per ASTM D714 for blistering Rating 10 per ASTM D1654 for corrosion Pencil Hardness:
Method: ASTM D3363 Result: 6B, 7 day air dry Salt Fog Resistance:
Method: ASTM B117, 500 hours Result: Rating 10N per ASTM D714 for blistering Rating 10 per ASTM D1654 for corrosion
Provides performance comparable to products formulated In Lieu of federal specification: AA50570, and Paint Specification: SSPC-Paint 24
RECOMMENDED SYSTEMS
As of 9/18/2015, Complies with:
OTC Yes LEED® 09 CI Yes SCAQMD Yes LEED® 09 NC Yes CARB Yes LEED® 09 CS Yes CARB SCM 2007 Yes LEED® 09 S Yes MPI NGBS Yes
*DeepBase and Ultradeep colors require a prime coat for maximum durability, adhesion, and corrosion protection. Application of coating on unprimed bare steel may cause pinpoint rusting.
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.
APPLICATION
Refer to the SDS before using Temperature: 50°F minimum 110°F maximum (Air, surface, and material) At least 5°F above dew point Relative humidity: 85% maximum
The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics. Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Airless Spray Pressure............................................ 1500 psi Hose ..................................................... 1/4" ID Tip ............................................... .017" - .021" Filter .................................................. 60 mesh Reduction .......................... Not recommended
Conventional Spray Gun ................................................... Binks 95 Fluid Nozzle Air Nozzle............................................... 63PB Atomization Pressure ........................... 50 PSI Fluid Pressure ................................. 10-20 PSI Reduction .......................... Not recommended
Brush .................................. Nylon / polyester Reduction .......................... Not recommended Due to this product's fast dry performance, brushing should be limited to small areas where a wet edge can be maintained
Roller ..................................... 1/4-3/8" woven Reduction ......................... Not recommended If specific application equipment is listed above, equivalent equipment may be substituted.
CLEANUP INFORMATION
Clean spills and spatters immediately with soap and warm water. Clean hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer's safety recommendations when using solvents.
HOTW 8/27/2015 B66W01151 08 35
KOR, SP, FRC
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
Do not use hydrocarbon solvents for cleaning.
Iron & Steel - Minimum surface preparation is Hand Tool Clean per SSPC-SP2. Remove all oil and grease from surface per SSPC-SP1. For better performance, use Commercial Blast Cleaning per SSPC-SP6. Primer recommended for best performance.
Aluminum - Remove all oil, grease, dirt, oxide and other foreign material per SSPC-SP1.
Galvanizing - Allow to weather a minimum of six months prior to coating. Solvent Clean per SSPC-SP1. When weathering is not possible, or the surface has been treated with chromates or silicates, first Solvent Clean per SSPC-SP1 and apply a test patch. Allow paint to dry at least one week before testing adhesion. If adhesion is poor, brush blasting per SSPC-SP7 is necessary to remove these treatments. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2, prime the area the same day as cleaned.
Concrete and Masonry - For surface preparation, refer to SSPC-SP13/NACE 6 or ICRI 03732, CSP 1-3. Surfaces should be thoroughly cleaned and dry. Surface temperatures must be at least 55°F before filling. If required for a smoother finish, use the recommended filler/surfacer.
The filler/surfacer must be thoroughly dry before topcoating per manufacturer's recommendations. Weathered masonry and soft or porous cement board must be brush blasted or power tool cleaned to remove loosely adhering contamination and to get to a hard, firm surface. Apply one coat Loxon Conditioner, following label recommendations.
Wood - Surface must be clean, dry and sound. Prime with recommended primer. No painting should be done immediately after a rain or during foggy weather. Knots and pitch streaks must be scraped, sanded and spot primed before full coat of primer is applied. All nail holes or small openings must be properly caulked.
Previously Painted Surfaces - If in sound condition, clean the surface of all foreign material.
Smooth, hard or glossy coatings and surfaces should be dulled by abrading the surface. Apply a test area, allowing paint to dry one week before testing adhesion. If adhesion is poor, additional abrasion of the surface and/or removal of the previous coating may be necessary.
Retest surface for adhesion. If paint is peeling or badly weathered, clean surface to sound substrate and treat as a new surface as above. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
APPLICATION PROCEDURES
Apply paint at the recommended film thickness and spreading rate as indicated on front page.
Application of coating above maximum or below minimum recommended spreading rate may adversely affect coating performance.
SAFETY PRECAUTIONS
Refer to the SDS sheets before use.
Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.